district heating › uploads › 5d249f60dc37700a5c7... · exchange station high-pressure/ low...

4
» Proven quality for over 40 years » TÜV certified double block and bleed » EN-488:2018 certified DISTRICT HEATING Together we take care of a reliable distribution www.klinger.be www.klinger.nl

Upload: others

Post on 28-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DISTRICT HEATING › uploads › 5d249f60dc37700a5c7... · Exchange station High-pressure/ Low pressure Manhole Sub-station entrance Sub-station Return Heat-exchanger DHW storage

» Proven quality for over 40 years» TÜV certified double block and bleed » EN-488:2018 certified

DISTRICT HEATINGTogether we take care of a reliable distribution

www.klinger.bewww.klinger.nl

Page 2: DISTRICT HEATING › uploads › 5d249f60dc37700a5c7... · Exchange station High-pressure/ Low pressure Manhole Sub-station entrance Sub-station Return Heat-exchanger DHW storage

KLINGER FLUID CONTROL VALVE SOLUTIONS FOR DISTRICT HEATING APPLICATIONS

Isolation of pumps

Pre-insulated EN 488:2015Chamber

Gallery

Heating supply and return Exchange Station

Isolation of boilers

Chamberor

Gallery12 4

56

PRODUCTION DISTRIBUTION DELIVERY(Piping network) (Sub-station)(Heat sources)

PRIMARYNETWORK

SECONDARYNETWORK

Steam or superheated water≥ 120 °C

hot water< 120° C

Exchange stationHigh-pressure/ Low pressure

Manhole

Sub-stationentrance

Sub-station

Return Return

Heat-exchanger DHW storage tank

Public water

Natural gas,municipal waste,biomass,geothermal,solar…

3

Ballostar » KHSVI VVS PN40

DN150 to 800 with drain cock (welding ends)

» KHI VVS PN40 DN150 to 800 with drain cock (flanges)

Ballostar » KHA SL PN40 DN15

to 125 (welding ends)» KHA FL PN40 DN15

to 125 (flanges)

Ballostar » KHA SL PN40 DN15

to 125 (welding ends)» KHA FL PN40 DN15

to 125 (flanges)

Piston valve» KVN PN25/PN40

DN15 to 50 (flanges)» KVSN PN63 DN15

to 50 (welding ends)

Piston valve» KVN PN25/PN40

DN15 to 50 (flanges)» KVSN PN63 DN15

to 50 (welding ends)

Piston valve » KVN PN40

DN65 to 200 (flanges)

Piston valve » KVN PN40

DN65 to 200 (flanges)

Ballostar » KHA SL

PN40 DN50 to 125 DBB with drain cock (welding ends)

» KHA FL PN40 DN50 to 125 with drian cock (flanges)

with

tigh

tnes

s co

ntro

l sys

tem

drai

n an

d ve

ntdr

ain

and

vent

with

tigh

tnes

s co

ntro

l sys

tem

Ballostar » KHSVI VVS

PN40 DN150 to 800 with drain cock (welding ends)

» KHI VVS PN40 DN150 to 800 with drain cock (flanges)

Ballostar » KHA SL PN40

DN50 to 125 DBB with drain cock (welding ends)

» KHA FL PN40 DN50 to 125 with drain cock (flanges)

Page 3: DISTRICT HEATING › uploads › 5d249f60dc37700a5c7... · Exchange station High-pressure/ Low pressure Manhole Sub-station entrance Sub-station Return Heat-exchanger DHW storage

Chamberor

Gallery12 4

56

PRODUCTION DISTRIBUTION DELIVERY(Piping network) (Sub-station)(Heat sources)

PRIMARYNETWORK

SECONDARYNETWORK

Steam or superheated water≥ 120 °C

hot water< 120° C

Exchange stationHigh-pressure/ Low pressure

Manhole

Sub-stationentrance

Sub-station

Return Return

Heat-exchanger DHW storage tank

Public water

Natural gas,municipal waste,biomass,geothermal,solar…

3

with

tigh

tnes

s co

ntro

l sys

tem

Pre-insulated Monoball EN 488:2015 with vent» KHSVI VVS PN25

/ PN40 DN150 to 800

Monoball » KHM-S PN25 / PN40

DN15 tot 250 (welding ends)

Monoball » KHM-F PN25 / PN40

DN15 tot 250 (flanges)

Ballostar » KHSVI VVS

PN40 DN150 to 800 with drain cock (welding ends)

» KHI VVS PN40 DN150 to 800 with drain cock (flanges)

Ballostar » KHA SL PN40 DN15

to 125 (welding ends)» KHA FL PN40 DN15

to 125 (flanges)

Ballostar » KHA SL PN40 DN15

to 125 (welding ends)» KHA FL PN40 DN15

to 125 (flanges)

Pre-insulated Monoball EN 488:2015 with vent and service valves» KHSVI VVS PN25 /

PN40 DN150 to 800

Ballostar» KHA SL

PN40 DN50 to DBB with drain cock (welding ends)

» KHA FL PN40 DN50 to 125 with drain cock (flanges)

Ballostar» KHA SL

PN40 DN50 to DBB with drain cock (welding ends)

» KHA FL PN40 DN50 to 125 with drain cock (flanges)

Priston valve» KVN PN25 / PN40

DN15 to 50 (flanges)» KVSN PN63 DN15 to

50 (welding ends)

Priston valve» KVN PN25 / PN40

DN15 to 50 (flanges)» KVSN PN63 DN15

to 50 (welding ends)

Pre-insulatedMonoball EN488:2015 » KHO PN40

/ PN25 DN20 to 125

Piston valve » KVN PN40

DN65 to 200 (flanges)

Piston valve » KVN PN40

DN65 to 200 (flanges)

Sub-station (at the heat-exchanger inlet)

Sub-station (at the heat-exchanger outlet)

drai

n an

d ve

nt

with

tigh

tnes

s co

ntro

l sys

tem

» Unique design; high degree of resilience against pipework forces and dirt.

» Complete range of valves (DN20 - DN1000).

02 | 03trusted. worldwide.

» Pre-insulated delivery possible.» EN-488:2018 certified.» TÜV certified double block and bleed.

Page 4: DISTRICT HEATING › uploads › 5d249f60dc37700a5c7... · Exchange station High-pressure/ Low pressure Manhole Sub-station entrance Sub-station Return Heat-exchanger DHW storage

KLINGER FOR SAFETY

» Quality & know-how » Cost savings (TCO)

» Emission reduction » Proven solutions

» E-business OCI / webshop » Dedicated specialists

“ Shaping the future of district heating”

KLINGER The Netherlands Nikkelstraat 2-4, 3067 GR Rotterdam

Postbus 8504, 3009 AM RotterdamThe Netherlands

T +31 (0)10 455 75 [email protected]

KLINGER Belgium NV/SAVilvoordsesteenweg 70

1120 Brussel (Neder-Over-Heembeek)Belgium

T: +32 (0)2 247 16 [email protected]

Edition 2019 - Typing and printing errors reserved