disturbance recording

Upload: ajs009

Post on 30-May-2018

223 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/14/2019 Disturbance Recording

    1/18

    HOW THE DISTURBANCE ATHOW THE DISTURBANCE AT

    GRIDS IS RECORDEDGRIDS IS RECORDED

    WE ARE NOW GOING TO LEARN ABOUTWE ARE NOW GOING TO LEARN ABOUTTHIS TOPICTHIS TOPIC

  • 8/14/2019 Disturbance Recording

    2/18

    Numerical Relays and DisturbanceNumerical Relays and DisturbanceRecordingRecording

    Numerical Relays AndDisturbance Recording

    By

    Engr. Syed Husnain Shah

  • 8/14/2019 Disturbance Recording

    3/18

    Conventional TechnologyConventional Technologycontrol panel, separate relay room, connectivity throughcontrol panel, separate relay room, connectivity through

    hardwiring.hardwiring.

    New TechnologyNew Technologylocal control, multifunction relays, connectivity through seriallocal control, multifunction relays, connectivity through serial

    communication.communication.

  • 8/14/2019 Disturbance Recording

    4/18

    Multipurpose protection relay series

    Voltage relays:

    REU 523 & REU 513

    Overcurrent & earth-fault relays:

    REJ 525 & REJ 515Overcurrent relays:

    REJ 523 & REJ 513

    Earth-fault relays:

    REJ 521 & REJ 511

    Directional earth-fault relays:

    REJ 527 & REJ 517

  • 8/14/2019 Disturbance Recording

    5/18

    Features

    A wide range of protection functions

    Wide and accurate numerical settings with perfectlong-time stability

    Two sets of relay settings available

    Recorded and time-stamped data of the latest 5 events Event code buffer of the latest 60 events

    Disturbance recording function for fault analysis

    Output relay functions freely configurable for trippingand signalling

    Circuit-breaker failure protection unit

  • 8/14/2019 Disturbance Recording

    6/18

    Features

    Binary input for blocking, external resetting, triggering and selection ofsetting group

    Optical serial interface on the front panel for communication with portablecomputer

    Powerful and easy-to-use software tools for relay setting

    High system reliability and availability due to continuoushardware and software self-supervision

    High immunity to electrical and electromagnetic interference

    Relay case with a degree of protection according to IP 54

    Rated frequency user-selectable 50/60 Hz

    CE marking according to the EC directive for EMC

  • 8/14/2019 Disturbance Recording

    7/18

    The supervision of your network will beThe supervision of your network will beenhanced by usingenhanced by using Numerical relaysNumerical relays

    11--Easy to useEasy to use -- ready made nfigurations =ready made nfigurations =local adaptations are not neededlocal adaptations are not needed

    22--Wide protection functionalityWide protection functionality -- covering thecovering the

    most essential protection functionsmost essential protection functions33--Condition monitoring functionsCondition monitoring functions -- forfor

    continuos supervisioncontinuos supervision

    44--Control functionsControl functions -- local or remotelocal or remote

    MeasurementsMeasurements

    55--ConnectivityConnectivity -- for remote control andfor remote control and

    monitoringmonitoring66--Easy to integrate in systems throughEasy to integrate in systems through

    communication protocolscommunication protocols

    77--Easy to orderEasy to order

  • 8/14/2019 Disturbance Recording

    8/18

    Functionality

    ControlControl

    Control of one circuit breakerControl of one circuit breaker

    Indication of 3 objectsIndication of 3 objects

    PrePre--programmed interlockingprogrammed interlocking

    conditionsconditions

    Condition MonitoringCondition Monitoring

    Self supervision (IRF)Self supervision (IRF)

    Trip circuit supervisionTrip circuit supervision

    CircuitCircuit--breaker wearbreaker wear

    Phase current supervision (MCSPhase current supervision (MCS3I)3I)

    Phase voltage supervision (MCSPhase voltage supervision (MCS3U)3U)

    CommunicationCommunication

    SPA, LON and IEC103SPA, LON and IEC103protocolprotocol

    Set values, measuredSet values, measuredvalues, registered values /values, registered values /

    events, uploading ofevents, uploading ofdisturbance recorder data,disturbance recorder data,control, etc. availablecontrol, etc. availabletrough communicationtrough communication

    Easy to useEasy to use

    Measured values shown asMeasured values shown asprimary valuesprimary values

    The settings are made inThe settings are made inprimary valuesprimary values

    Easy menu navigationEasy menu navigation

    MMI in several languagesMMI in several languages

  • 8/14/2019 Disturbance Recording

    9/18

    Everything in one box

  • 8/14/2019 Disturbance Recording

    10/18

    Flexibility

    Full range of protection, measuring,

    control and supervision functions

    Large amount of generic functions

    Freely drawable mimic view

    Freely programmable alarm indications

    Freely configurable function button

    Application-specific functionality

  • 8/14/2019 Disturbance Recording

    11/18

    Protection FunctionsProtection Functions AutoAuto--reclosing (reclosing (55 shots)shots)

    Phase discontinuityPhase discontinuity

    NonNon--directional earthdirectional earth--faultfault

    Directional earthDirectional earth--faultfault

    NonNon--directional overcurrentdirectional overcurrent Directional overcurrentDirectional overcurrent

    Under/overfrequencyUnder/overfrequency

    Transformer inrush and motorTransformer inrush and motorstartstart--up current detectorup current detector

    OvervoltageOvervoltage UndervoltageUndervoltage

    Residual overvoltageResidual overvoltage Synchro/voltageSynchro/voltage--checkcheck

    Thermal overload for cablesThermal overload for cables

  • 8/14/2019 Disturbance Recording

    12/18

    Substation automation (SCS)

    Protection

    Monitoring and control

    Communication with NCC

    Power quality measurements

    Time synchronization

    Interlocking Metering

    MV & HV

  • 8/14/2019 Disturbance Recording

    13/18

    Event Capture From Aug. 14,Event Capture From Aug. 14,

    20032003

  • 8/14/2019 Disturbance Recording

    14/18

  • 8/14/2019 Disturbance Recording

    15/18

    How are you Feeling?????? AfterHow are you Feeling?????? Afterlistening to this lecture????listening to this lecture????

  • 8/14/2019 Disturbance Recording

    16/18

    You must be feeling Like..You must be feeling Like..

  • 8/14/2019 Disturbance Recording

    17/18

    This??????

  • 8/14/2019 Disturbance Recording

    18/18

    THANKS FOR YOUR PATIENCETHANKS FOR YOUR PATIENCE