dn02-s09011-e-xk-6553-00
DESCRIPTION
6553TRANSCRIPT
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
F F
E E
D D
C C
B B
A A
Grey
b
W9
Black
a
Black
Grey
W8
Cu-bar
W4
3M. 3770/26
3M. 3770/20
Cufl.
3M. 3770/20
Black
TEXline HF90 Yellow/Gr.
Cu
W12
NSHXAFØ 1)
WIRING REFERENCE
j
Cu-bar flexible
W3
0.75mm2
3M. 3770/26
0.75mm2
3M. 3770/20
Tefzel 1) Grey
Grey
Distance Bolt
3M. 3770/16
W10
W1
W11
Tefzel 1)
1) Short Circuit Proof
WIRE
Grey
Grey
4x
TEXline HF90
COLOUR
0.61mm2
W5
e
Grey
Grey
Orange
W7
l
Tefzel 1)
Tefzel 1)
W6
White
Di
f
TEXline HF90
Grey
Grey3M. 3770/26
7x
3M. 3770/26
Black
Black
CODE
Grey
0.61mm2
3M. 3770/26
Black
h
3M. 3770/16
0.61mm2
i
W2
TEXline HF90
k
3M. 3770/20
0.61mm2
Grey
Grey
AREA
3M. 3770/26
NORSKE
Rev:
Date
Sheets:Sheet:
Area:
4
Made by
2
SMOE
Tag no.
Drawing No.:
Chc. by
1 3
Installation: Ivar Aasen Field
P.O.NumberDrawing Title:
DWG Size
Description
Signature:
DET
Development Project - PDQ Platform
+Scale
S09011
Wood Group
=
Date:
Issue
Mustang
Supplier
Siemens Dwg. No.:
Appr. by
Acceptance Code:
System:
5
NA
85ED0902A, 85ED0200B
IF YOU HAVE A CABLE I.A: 2,5f
DN02-S09011-E-XK-6553-00 2VDa
VDa
ISSUED FOR CONSTRUCTIONS
2,5 IS THE SIZE OF CABLE, HERE 2,5mm2
.
02I
01E
UPS SYSTEM LIGHTING -
03L ISSUED FOR REVIEW
.
HFO
As Built
.
03L
f IS THE TYPE OF CABLE, HERE NSHXFØ
30.06.14
.
17.07.14
.
SWe
SWe
285
NOTE:
.
UPS CIRCUIT/WIRING DIAGRAMS
M120,L00 51PO-04193.265-K-053-01
HFO
VDa
HFO 1
19.12.14
A3 SWe
BATTERY BREAKER
17-01-15 A. Gonzalez
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
F F
E E
D D
C C
B B
A A
I > I > I >
T
NORSKE
Rev:
Date
Sheets:Sheet:
Area:
4
Made by
2
SMOE
Tag no.
Drawing No.:
Chc. by
1 3
Installation: Ivar Aasen Field
P.O.NumberDrawing Title:
DWG Size
Description
Signature:
DET
Development Project - PDQ Platform
+ Scale
S09011
Wood Group
=
Date:
Issue
Mustang
Supplier
Siemens Dwg. No.:
Appr. by
Acceptance Code:
System:
5
SWe
-Q21* <U
.
23
/.2
A2
-X3
52
1f
UPS SYSTEM LIGHTING -
BATTERY BREAKER
S13
A1
-K3
1
14
1 f
3
/.1
-Q29
HFO
-K2
.
IN BATTERY ROOM
/.4
.
-K4
1f
HFO
1
1f
13
M120,L0017.07.14
9
RESET T
IMER
10
NA
SWITCH
NO
RM
ALY
ENERG
IZED
14
51
-K4
4
4
/.4
A2
TRIP
S14
8
X3:3
/.3
-K3
CONNECTION TO BATTERY
S22
(+)
/.3
-K3
/.4
2,5mm2
D2
7
As Built
A1
A3
X3:3
TRIP WHEN OPENED
C(-)
95 f
14
13
2
-X3
12
1f
X3:1
52
2,5mm2
13
POWER SUPPLY 24V DC
4
03L
-R29
4
1f
5 7
3
VDa
DELAYED
TR
IP
A1
X3:1
-X1
1f
OVERRIDE
CONNECTION TO UPS
1
X3:2
-K1
X3:4
14
VDa
A21
SWe
-K1
5
85
/.4
14
/.1
1f
/.1
-A21
S21
51PO-04193.265-K-053-01
-Q21
(-)
2
X3:2
52
2
52
1 f
4
BATTERY B
REAKER
1
4
51
2
3
30.06.14DN02-S09011-E-XK-6553-00
/.7
2,5mm2
14
/.4
UPS CIRCUIT/WIRING DIAGRAMS
-X1
1f
IMEIDIATE TRIP
-K4
VDa
(-)
/.2
-K2
5
-S1
TRIP
OVERR
IDE
19.12.14
.
1f
A2
10
1f
/.3
1 f
4
/.1
/.3
2
51
03L
UVT
6
316 - 436V DC
3
51
Cu
02I
Y1
0V
/.4
X3:4
C(+)
1f
13
13
AC
TIV
ATED
51
85ED0902A, 85ED0200B
2 34
-X3
C(-)
14
A1
6
/.5
ISSUED FOR REVIEW
1f
1
/.1
/.7
Cu
1 f
2
-X3
3
-K3
2
Cu
51
UNDERVOLTAGE TRIP
C(+)
-X1
1
3
/.2
.
-X2
2
+24V
-K2 52
HFO
BLACK-START
4
13
11
/.2
8
24
-K2
Y2
3
(+)
2
9
SWe
.
33
13
52
6
STATUS S
IGN
AL
95 f
D1
NO
RM
ALY
DE-E
NER
GIZ
ED
/.1
(BATTERY BREAKER I EExde CABINET)
2,5mm2
ISSUED FOR CONSTRUCTIONS
01E
-K1
3
17-01-15 A. Gonzalez