domekt cf 700 h - tzbprodukt.sk · 59 domekt domekt cf 700 h (kompakt recu 700hcf) a 770 m³/h 41...

1
59 DOMEKT DOMEKT CF 700 H (Kompakt RECU 700HCF) A 770 m³/h 41 770 45 95 1~230 HE 12 / HW 3,8 86 0,15 50 0,3 390×300×46-M5 78 170 2,0 / 7,2 KOMFOVENT C5.1 2,2 2,2 2,2 2,2 95 95 95 95 1 1 1 1 13,7/22 7,2 5,8 4,5 3,2 ½ 365×365×220 DH-250 13,7 14,9 15,9 16,8 17,8 23,5 46 66 51 66 41 30 0 200 400 600 800 1000 0 0,05 0,1 0,15 0,2 0,25 500 400 300 200 100 0 SFP 1,25 SFP 0,75 SFP 0,5 SFP 1 1500 250 (4×) 245 200 300 490 1540 700 C D D A A B B A C D 97 92 87 82 100 200 300 400 500 600 700 800 D=15 mm C5.1 KK2-16-03 UAB AMALVA reserves the right to introduce the changes of parameters and sizes in the process of improvement of the air handling units. All data can be calculated in DOMEKT selection software. If data of performance do not correspond to data in the selection software, please refer to data shown in software. The photo is intended for informational purposes only, exact details may vary. Static pressure (Pa) Performance Air flow rate (m 3 /s) Air flow rate (m 3 /h) Air flow rate (m 3 /h) Temp. efficiency (%) Temperature efficiency Indoor and outdoor ∆T=13°C re: Ecodesign 1254/2014. Acoustic Data A-weighted sound power level L WA , dB(A) at reference flow rate Supply Inlet Supply Outlet Exhaust Inlet Exhaust Outlet Casing A-weighted sound pressure level L PA , dB(A) 10 m² normally isolated room, distance from casing – 3 m. Surroundings Nominal air flow, m³/h Panel thickness, mm Unit weight, kg Supply voltage, V Maximal operating current, A Thermal efficiency of heat recovery, % Reference flow rate, m³/s Reference pressure difference, Pa SPI, W/(m³/h) Filters dimensions B×H×L, mm Electric power input of the fan drive at reference flow rate, W Electric power input of the fan drive at maximum flow rate, W Electric air heater capacity, kW / ∆t, °C Control panel Hot water duct air heater (DH)** Winter Water temperature in/out, °C 90/70 80/60 70/50 60/40 Capacity, kW Flow rate, dm³/h Pressure drop, kPa Temperature in/out, °C Maximal capacity, kW Connection, ” Dimensions, mm Hot water duct heater type ** option Temperature efficiency Winter Summer Outside temperature, °C -23 -15 -10 -5 0 30 After heat exchanger*, °C * indoor +22°C, 20 % RH A outdoor intake B supply air C extract indoor D exhaust air Shown as right (R1) Shown as left (L1)

Upload: others

Post on 14-Mar-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DOMEKT CF 700 H - tzbprodukt.sk · 59 domekt domekt cf 700 h (kompakt recu 700hcf) a 770 m³/h 41 770 45 95 1~230 he 12 / hw 3,8 86 0,15 50 0,3 390×300×46-m5 78 170 2,0 / 7,2 komfovent

59

DOMEKT

DOMEKT CF 700 H (KompaktRECU700HCF)

A

770 m³/h41

770

45

95

1~230

HE 12 / HW 3,8

86

0,15

50

0,3

390×300×46-M5

78

170

2,0 / 7,2

KOMFOVENT C5.1

2,2 2,2 2,2 2,2

95 95 95 95

1 1 1 1

13,7/22

7,2 5,8 4,5 3,2

½

365×365×220

DH-250

13,7 14,9 15,9 16,8 17,8 23,5

46

66

51

66

41

30

0 200 400 600 800 1000

0 0,05 0,1 0,15 0,2 0,25500

400

300

200

100

0

SFP 1,25

SFP 0,75

SFP 0,5

SFP 1

1500

250 (4×)

245

200

300

490

1540

700

C

D D

A A

B

B

A C

D

97

92

87

82 100 200 300 400 500 600 700 800

D=15 mm

C5.1

KK2-16-03UAB AMALVA reserves the right to introduce the changes of parameters and sizes in the process of improvement of the air handling units.

All data can be calculated in DOMEKT selection software. If data of performance do not correspond to data in the selection software, please refer to data shown in software.

The

phot

o is

inte

nded

for i

nfor

mat

iona

l pur

pose

s on

ly, e

xact

det

ails

may

var

y.

Stat

ic p

ress

ure

(Pa)

Performance Air flow rate (m3/s)

Air flow rate (m3/h)

Air flow rate (m3/h)

Tem

p. e

ffici

ency

(%)

Temperature efficiency

Indoor and outdoor ∆T=13°C re: Ecodesign 1254/2014.

Acoustic DataA-weighted sound power level LwA, dB(A)at reference flow rate

Supply Inlet

Supply Outlet

Exhaust Inlet

Exhaust Outlet

Casing

A-weighted sound pressure level LPA, dB(A) 10 m² normally isolated room, distance from casing – 3 m.

Surroundings

Nominal air flow, m³/h

Panel thickness, mm

Unit weight, kg

Supply voltage, V

Maximal operating current, A

Thermal efficiency of heat recovery, %

Reference flow rate, m³/s

Reference pressure difference, Pa

SPI, W/(m³/h)

Filters dimensions B×H×L, mm

Electric power input of the fan drive at reference flow rate, W

Electric power input of the fan drive at maximum flow rate, W

Electric air heater capacity, kW / ∆t, °C

Control panel

Hot water duct air heater (DH)**Winter

Water temperature in/out, °C 90/70 80/60 70/50 60/40

Capacity, kW

Flow rate, dm³/h

Pressure drop, kPa

Temperature in/out, °C

Maximal capacity, kW

Connection, ”

Dimensions, mm

Hot water duct heater type

** option

Temperature efficiencyWinter Summer

Outside temperature, °C -23 -15 -10 -5 0 30

After heat exchanger*, °C

* indoor +22°C, 20 % RH

A outdoor intakeB supply airC extract indoorD exhaust air

Shown as right (R1)

Shown as left (L1)