door/window sensor installation instructions€¦ · © 2015 ecolink intelligent technology inc. pn...
TRANSCRIPT
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
Door/WindowSensorInstallationInstructions
ProductOverview• Z-Wave+™enableddevicewhichprovidesopen/closedpositionstatus• Transmitsopen/closedstatus• Reportstamperconditionwhencoverisopen
ProductSpecifications• Forindooruseonly• Operatingfrequency:908.42MHz• Operationrange:Upto100feet(30.5meters)line-of-sight• Operatingtemperature:0°–49°C,32°–120°F(ambienttemperature)• Batterytyperequired:3VLithiumCR123A• Batterylifeapproximately3years
NetworkInclusionThesensormustbeaddedtoaZ-Wavenetworkpriortouse.Toincludethesensorinanetworkboththesensorandthenetworkcontrollermustbeininclusionmodeatthesametime.Refertotheinstructionsprovidedbythemanufacturerofyourspecificcontrollerfordetailsoninitiatingthecontroller’sinclusionmode. STEPONE Startbyplacingthecontrollerintoinclusionmode.STEPTWO Activateinclusionmodeforthesensorbyremovingtheplasticpull-tabfromthebackofthesensor.Whentheinclusionprocess
incomplete,theLEDonthesensorwillbesolidblue,thengoout.STEPTHREE Testthesensor.Placethemagnetnexttothesensortorepresentaclosedposition(seeInstallationsectiontoseewhereto
positionthemagnet).IftheLEDflashesONETIME,itissuccessfullycommunicatingonyourZwavenetwork.IftheLEDonthesensorflashesslowandsteadyfor5seconds,youneedtorepeattheinclusionprocess.
Notes: Ifyouneedtorepeattheinclusionprocess,repeatSTEPONEabove,thenforSTEPTWOyouwillneedtosimplyremovethecoverofthesensor,removethebatteryfor10
seconds,reinsertthebattery,andreplacethesensorcover.Thiswillre-enterthesensorininclusionmode.
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
NetworkInclusion:KeyPointstoRemember• ControllerinclusionmodemustbeactivatedBEFOREstartingsensorinclusionmode.• Thesensorcanonlybeincludedintoonecontrollernetworkatatime,andmustbeexcludedfromonenetworkbeforeinclusioninanother.• Removingthepulltabconnectsthebatteryandinitiatessensorinclusionmode.Inclusionmodecanalsobeinitiatedbyremovingthebatteryforatleast5seconds,reinstallingthebattery,
thenreplacingthesensorcover.• Theplasticpulltabmustberemovedtoenablesensoroperation.• Thesensorautomaticallyentersinclusionmodeatpower-up.• Exclusionmodeonthesenorisinitiatedfollowingthesameexactprocedureasinclusion.
InstallationThepackagecontainsthefollowing:
1- Door/WindowSensor1- SensorMountingBracket2- ScrewsforSensorMountingBracket1- AdhesivetapeforSensorMountingBracket1- SensorMagnet2- ScrewsforSensorMagnet1- AdhesivetapeforSensorMagnet
STEPONE IdentifyLocationforSensorandMagnet: Determinewhereonthedoororwindowyouareabletomountthesensorandmagnet.Note,thatthesensorhasalineandarrowthatidentify
wherethemagnetshouldbelocated,relativetothesensor.
Thesensoristypicallyattachedtothenon-movingpartofthedoororwindow(i.e.thedoorjamborwindowframe).Foryourconveniencetwomountingmethodsareprovided.Thesensorcanbemountedwithadhesivetapeand/orscrews.
Firstmakesureyouhaveaflatcleansurfacetomountthesensorandmagnetto.Pleaseverifythecorrectorientationofthesensorandlocationofthemagnetbeforeyoucontinueontomountingthesensorandmagnet.
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
MagnetLocation
Lefthanddoormounting(arrowpointingUP,magnetonleftside) Righthanddoormounting(arrowpointingdown,magnetonrightside)STEPTWO Mountthesensorandmagnettoacleandrysurfacewiththeadheasivetapeand/orthescrewsprovided
Fixedjamb
Door
AdhesiveTape
MountingBracket
Screws(optional)
Sensor
AdhesiveTape
MountingBracket
Screws(optional)
Magnet
Fixedjamb
Door
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
ADDITIONALNOTESANDSUMMARY:
• Witheithermountingmethodthefirststepistoattachthesensormountingbrackettodoorframeorwindowframe.(Themountingbracketisusedregardlessofchoiceofscrewsortape).
• Thesensorcanslideontothemountingbracketintwodifferentways.Toensurethatthesensorissecurelyfasteneditisrecommendedthatthetabonthebracketengagethebackofthesensor.
• Beforeattachingthebrackettoasurfacenotehowthebracketwillneedtobeorientedinorderforthetabtoengagethesensor.Therequiredorientationofthesensordeterminesthebracketorientation.
• Thesensorslidesontothebracketuntilthetabengages.Pleasebeadvisedthatadhesivetapemaydamagethesurfacestowhichitisattached.
BROWNPLASTICHOUSINGS(OPTIONAL)
IncludedwitheveryEcolinkDoor/WindowSensorisasecondsetofplasticsinBROWN.Ifyourdoororwindowisdarkerincolor,youmaychoosetousetheBROWNcoverforthesensorandtheBROWNplasticsforthemagnet.
MAXGAP:5/8”IMPORTANT: Theedgeofthemagnetmustalignwiththelineonthesensor,ANDthemagnetmustlocate
nexttothearrowonthesensor.Maximumgapbetweenthemagnetandthesensoris5/8”.
Ifthemagnetisnotlocatedfollowingtheserules,thesensormaynotgetactivated.
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
WhatisZ-Wave?
TheZ-Waveprotocolisaninteroperable,wireless,RF-basedcommunicationstechnologydesignedspecificallyforcontrol,monitoringandstatusreadingapplicationsinresidentialandlightcommercialenvironments.Mature,provenandbroadlydeployed(withover35millionproductssoldworldwide),Z-Waveisbyfartheworldmarketleaderinwirelesscontrol,bringingaffordable,reliableandeasy-to-use'smart'productstomanymillionsofpeopleineveryaspectofdailylife.CertifiedZ-WavedevicesregardlessofmanufacturercanworktogethertoformaZ-Wavemeshnetwork.AlwaysonZ-Wavedevicescanactasrepeatersinthemeshincreasingrangeandredundancy.
ForamorecompletelookatZ-Wavetechnologyfornon-technologists,andtolearnmoreaboutZ-Wave'sroleasakeyenablingtechnologyfortheInternetofThingsandconnectedobjects,pleasevisitwww.z-wave.com.
Z-WaveDeviceClassandCommandClassInformation
ThisZ-WavesensorisaZ-WavegenericDeviceClassofGENERIC_TYPE_SENSOR_NOTIFICATION,andaspecificdeviceclassofSPECIFIC_TYPE_NOTIFICATION_SENSOR,andthesupportedcommandclassesareCOMMAND_CLASS_ZWAVEPLUS_INFO,COMMAND_CLASS_VERSION,COMMAND_CLASS_MANUFACTURER_SPECIFIC,COMMAND_CLASS_POWERLEVEL,COMMAND_CLASS_BATTERY,COMMAND_CLASS_NOTIFICATION_V4,COMMAND_CLASS_ASSOCIATION,COMMAND_CLASS_ASSOCIATION_GRP_INFO,COMMAND_CLASS_WAKE_UP,COMMAND_CLASS_SENSOR_BINARY,COMMAND_CLASS_CONFIGURATION,COMMAND_CLASS_BASIC.
ManufacturerSpecific
ManufacturerID:0x014A
ProductType:4
ProductID:2
FactoryDefault
Torestorethissensortofactorydefaultsettings,followtheinstructionsinthismanualtoexcludethissensorfromtheZ-Wavenetwork.Uponcompletionofremovalfromthenetworkthesensorwillrestoreitselftofactorydefaultsettingsautomatically.Usethisprocedureonlyintheeventthatthenetworkprimarycontrollerismissingorotherwiseinoperable.
KeepingAwakeforTestingandConfiguration
Tosavepower,thissensorsleepsmostofthetimeandisthereforenotawaketoreceivemessagesfromagatewayfortesting.Removingthetopcasefromthesensorwillputindeviceintoatamperedmodeinwhichthesensorwillstayawakeandabletoreceivemessages.Mostofthetimeanenduserwouldnotdothis,butifthesensorneedstobeconfiguredafterinclusion,anendusercanfollowtheinstructionsbelowforsendingWake-Upnotifications.
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
Association
ThissensorhastwoAssociationgroupsof5nodeseach.Grouponeisalifelinegroupwhowillreceiveunsolicitedmessagesrelatingtodoor/windowopen/closenotifications,casetamperingnotifications,low-batterynotifications,andsensorbinaryreports.Group2isintendedfordevicesthataretobecontrolledi.e.turnedonoroff(ononlybydefault)withaBasicSet.OninclusionthecontrollershouldputitsnodeIDingroup1butnotgroup2.
NetworkWideInclusion
ThissensoralsosupportsNetworkWideInclusionsuchthattheSensorcanbeincludedintotheZ-Wavenetworkoverthemeshnetworkandnotdirectlynearthemaincontroller.Thismodeisautomaticallyactivatedafterregularinclusionwasnotsuccessful
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
SENSORCONDITION
COMMANDCLASSandVALUE ASSOCIATIONGROUP CONFIGURABLE?
Door/WindowOpen
NotificationReportofAccessControl(0x06),Door/Windowisopen(0x16)
1
YesviaNotificationSetofnotificationType(0x06)andstatusof0x00:Thistypeof
notificationturnedoff0xFF:Thistypeofnotificationturnedon
SensorBinaryReportof0xFFSensorType:0xFF
1
YesviaConfigurationCommandClassParameterNumber:2Size:1AConfigurationValue:0xFF(On)/0x00(Off)
Basicsetof0xFF(On) 2 No
Door/WindowClose
NotificationReportofAccessControl(0x06),Door/Windowisclosed(0x17)
1
YesviaNotificationSetofnotificationType(0x06)andstatusof0x00:Thistypeof
notificationturnedoff0xFF:Thistypeofnotificationturnedon
SensorBinaryReportof0x00SensorType:0xFF
1
YesviaConfigurationCommandClassParameterNumber:2Size:1AConfigurationValue:0xFF(On)/0x00(Off)
BasicSetof0x00(Off)ByfactorydefaultthisfeatureisdisabledandmustbeenabledviaConfiguration
CommandClass.
2 YesviaConfigurationCommandClassParameterNumber:1Size:1AConfigurationValue:0xFF(On)/0x00(Off)ParameterNumber:2
SensorCaseRemoved
NotificationReportofHomeSecurity(0x07),Tamperingproductcover
removed(0x03)
1
YesviaNotificationSetofnotificationType(0x07)andstatusof0x00:Thistypeof
notificationturnedoff0xFF:Thistypeofnotificationturnedon
SensorCaseFastened Wake-UpNotification 1 YesviaWake-UpNotificationCommandClass
BatteryLevelDippedBelow2.6v NotificationReportofPowerManagement(0x08),Replacebattery
now(0x0B)
1
YesviaNotificationSetofnotificationType(0x08)andstatusof0x00:Thistypeof
notificationturnedoff0xFF:Thistypeofnotificationturnedon
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
Wake-UpNotification
ThesensorwillwakeupeverysooftenandwhenthecaseisclosedtosendaWake-UpNotificationtoallowthelifelinemasternodecontrollerthatthesensorisnowavailableforanyqueuedmessagesthatthecontrollermayhaveforthesensor.ThetimebetweenWake-UpNotificationscanbeconfiguredwiththeWake-UpNotificationcommandclasstobebetween1hourand1weekwithintervalstepsof200seconds.
Configuration
Thesensorhastwoconfigurationparameters.Parameter1configuresthesensortosendornotsendBasicSetcommandsof0x00tonodesinAssociationgroup2turningthedevicesoffwhenthesensorisinarestoredstatei.e.thedoorisclosed.BydefaultthesensordoesNOTsendBasicSetcommandsof0x00.Parameter2configuresthesensortoeithertosendornottosendSensorBinaryReportcommandstoAssociationGroup1whenthesensorisfaultedandrestored.IfthecontrollerisfullycompatiblewiththeNotificationCommandClasstherebymakingtheSensorBinaryReportsredundant,thecontrollercandisabletheSensorBinaryReportCommandscompletely.Thefollowingtableshowsthevaluestoenableanddisablethetwoconfigurationparameters.
ConfigurationSetValues EffectParameterNumber:1Size:1ConfigurationValue:0x00
(Default)SensordoesNOTsendBasicSetstoNodeIDsinAssociationGroup2whenthesensorisrestored(i.e.Door/WindowClosed).
ParameterNumber:1Size:1ConfigurationValue:0xFF
SensorsendsBasicSetsof0x00tonodesinAssociationGroup2whensensorisrestored.
ParameterNumber:2Size:1ConfigurationValue:0x00
(Default)SensorsendsSensorBinaryReportswhensensorisfaultedandrestoredforbackwardscompatibilityinadditiontoNotificationReports.
ParameterNumber:2Size:1ConfigurationValue:0xFF
SensorwillsendonlyNotificationReportsandNOTSensorBinaryReportswhenthesensorisfaultedandrestored.
©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04
FCCComplianceStatement
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforClassBdigitaldevices,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:
• Re-orientorrelocatethereceivingantenna• Increasetheseparationbetweentheequipmentandreceiver• Connecttheequipmenttoanoutletonadifferentcircuitfromthereceiver• Consultthedealeroranexperiencedradio/TVcontractorforhelp.
Warning:ChangesormodificationsnotexpresslyapprovedbyEcolinkIntelligentTechnologyInc.couldvoidtheuser’sauthoritytooperatetheequipment.
ThisdevicecomplieswithIndustryCanadalicense-exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.
C’etappareilestconformelanormed'IndustrieCanadaexemptsdelicenceRSS.Sonfonctionnementestsoumisauxdeuxconditionssuivantes:(1)c’etappareilnepeutpasprovoquerd'interférences,et(2)c’etappareildoitacceptertouteinterférence,ycomprislesinterférencesquipeuventcauserunmauvaisfonctionnementdeladispositif.
FCCID:TBDIC:TBD
Warranty
EcolinkIntelligentTechnologyInc.warrantsthatforaperiodof3yearsfromthedateofpurchasethatthisproductisfreefromdefectsinmaterialandworkmanship.Thiswarrantydoesnotapplytodamagecausedbyshippingorhandling,ordamagecausedbyaccident,abuse,misuse,misapplication,ordinarywear,impropermaintenance,failuretofollowinstructionsorasaresultofanyunauthorizedmodifications.
IfthereisadefectinmaterialsandworkmanshipundernormalusewithinthewarrantyperiodEcolinkIntelligentTechnologyInc.shall,atitsoption,repairorreplacethedefectiveequipmentuponreturnoftheequipmenttotheoriginalpointofpurchase.
Theforegoingwarrantyshallapplyonlytotheoriginalbuyer,andisandshallbeinlieuofanyandallotherwarranties,whetherexpressedorimpliedandofallotherobligationsorliabilitiesonthepartofEcolinkIntelligentTechnologyInc.neitherassumesresponsibilityfor,norauthorizesanyotherpersonpurportingtoactonitsbehalftomodifyortochangethiswarranty,nortoassumeforitanyotherwarrantyorliabilityconcerningthisproduct.ThemaximumliabilityforEcolinkIntelligentTechnologyInc.underallcircumstancesforanywarrantyissueshallbelimitedtoareplacementofthedefectiveproduct.Itisrecommendedthatthecustomerchecktheirequipmentonaregularbasisforproperoperation.
DesignedinCarlsbad,CAwww.discoverecolink.com