door/window sensor installation instructions€¦ · © 2015 ecolink intelligent technology inc. pn...

9
© 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview Z-Wave+™ enabled device which provides open/closed position status Transmits open/closed status Reports tamper condition when cover is open Product Specifications For indoor use only Operating frequency: 908.42 MHz Operation range: Up to 100 feet (30.5 meters) line-of-sight Operating temperature: 0° – 49°C, 32° – 120°F (ambient temperature) Battery type required: 3V Lithium CR123A Battery life approximately 3 years Network Inclusion The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network both the sensor and the network controller must be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controller’s inclusion mode. STEP ONE Start by placing the controller into inclusion mode. STEP TWO Activate inclusion mode for the sensor by removing the plastic pull-tab from the back of the sensor. When the inclusion process in complete, the LED on the sensor will be solid blue, then go out. STEP THREE Test the sensor. Place the magnet next to the sensor to represent a closed position (see Installation section to see where to position the magnet). If the LED flashes ONE TIME, it is successfully communicating on your Zwave network. If the LED on the sensor flashes slow and steady for 5 seconds, you need to repeat the inclusion process. Notes: If you need to repeat the inclusion process, repeat STEP ONE above, then for STEP TWO you will need to simply remove the cover of the sensor, remove the battery for 10 seconds, reinsert the battery, and replace the sensor cover. This will re-enter the sensor in inclusion mode.

Upload: others

Post on 07-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

Door/WindowSensorInstallationInstructions

ProductOverview• Z-Wave+™enableddevicewhichprovidesopen/closedpositionstatus• Transmitsopen/closedstatus• Reportstamperconditionwhencoverisopen

ProductSpecifications• Forindooruseonly• Operatingfrequency:908.42MHz• Operationrange:Upto100feet(30.5meters)line-of-sight• Operatingtemperature:0°–49°C,32°–120°F(ambienttemperature)• Batterytyperequired:3VLithiumCR123A• Batterylifeapproximately3years

NetworkInclusionThesensormustbeaddedtoaZ-Wavenetworkpriortouse.Toincludethesensorinanetworkboththesensorandthenetworkcontrollermustbeininclusionmodeatthesametime.Refertotheinstructionsprovidedbythemanufacturerofyourspecificcontrollerfordetailsoninitiatingthecontroller’sinclusionmode. STEPONE Startbyplacingthecontrollerintoinclusionmode.STEPTWO Activateinclusionmodeforthesensorbyremovingtheplasticpull-tabfromthebackofthesensor.Whentheinclusionprocess

incomplete,theLEDonthesensorwillbesolidblue,thengoout.STEPTHREE Testthesensor.Placethemagnetnexttothesensortorepresentaclosedposition(seeInstallationsectiontoseewhereto

positionthemagnet).IftheLEDflashesONETIME,itissuccessfullycommunicatingonyourZwavenetwork.IftheLEDonthesensorflashesslowandsteadyfor5seconds,youneedtorepeattheinclusionprocess.

Notes: Ifyouneedtorepeattheinclusionprocess,repeatSTEPONEabove,thenforSTEPTWOyouwillneedtosimplyremovethecoverofthesensor,removethebatteryfor10

seconds,reinsertthebattery,andreplacethesensorcover.Thiswillre-enterthesensorininclusionmode.

Page 2: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

NetworkInclusion:KeyPointstoRemember• ControllerinclusionmodemustbeactivatedBEFOREstartingsensorinclusionmode.• Thesensorcanonlybeincludedintoonecontrollernetworkatatime,andmustbeexcludedfromonenetworkbeforeinclusioninanother.• Removingthepulltabconnectsthebatteryandinitiatessensorinclusionmode.Inclusionmodecanalsobeinitiatedbyremovingthebatteryforatleast5seconds,reinstallingthebattery,

thenreplacingthesensorcover.• Theplasticpulltabmustberemovedtoenablesensoroperation.• Thesensorautomaticallyentersinclusionmodeatpower-up.• Exclusionmodeonthesenorisinitiatedfollowingthesameexactprocedureasinclusion.

InstallationThepackagecontainsthefollowing:

1- Door/WindowSensor1- SensorMountingBracket2- ScrewsforSensorMountingBracket1- AdhesivetapeforSensorMountingBracket1- SensorMagnet2- ScrewsforSensorMagnet1- AdhesivetapeforSensorMagnet

STEPONE IdentifyLocationforSensorandMagnet: Determinewhereonthedoororwindowyouareabletomountthesensorandmagnet.Note,thatthesensorhasalineandarrowthatidentify

wherethemagnetshouldbelocated,relativetothesensor.

Thesensoristypicallyattachedtothenon-movingpartofthedoororwindow(i.e.thedoorjamborwindowframe).Foryourconveniencetwomountingmethodsareprovided.Thesensorcanbemountedwithadhesivetapeand/orscrews.

Firstmakesureyouhaveaflatcleansurfacetomountthesensorandmagnetto.Pleaseverifythecorrectorientationofthesensorandlocationofthemagnetbeforeyoucontinueontomountingthesensorandmagnet.

Page 3: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

MagnetLocation

Lefthanddoormounting(arrowpointingUP,magnetonleftside) Righthanddoormounting(arrowpointingdown,magnetonrightside)STEPTWO Mountthesensorandmagnettoacleandrysurfacewiththeadheasivetapeand/orthescrewsprovided

Fixedjamb

Door

AdhesiveTape

MountingBracket

Screws(optional)

Sensor

AdhesiveTape

MountingBracket

Screws(optional)

Magnet

Fixedjamb

Door

Page 4: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

ADDITIONALNOTESANDSUMMARY:

• Witheithermountingmethodthefirststepistoattachthesensormountingbrackettodoorframeorwindowframe.(Themountingbracketisusedregardlessofchoiceofscrewsortape).

• Thesensorcanslideontothemountingbracketintwodifferentways.Toensurethatthesensorissecurelyfasteneditisrecommendedthatthetabonthebracketengagethebackofthesensor.

• Beforeattachingthebrackettoasurfacenotehowthebracketwillneedtobeorientedinorderforthetabtoengagethesensor.Therequiredorientationofthesensordeterminesthebracketorientation.

• Thesensorslidesontothebracketuntilthetabengages.Pleasebeadvisedthatadhesivetapemaydamagethesurfacestowhichitisattached.

BROWNPLASTICHOUSINGS(OPTIONAL)

IncludedwitheveryEcolinkDoor/WindowSensorisasecondsetofplasticsinBROWN.Ifyourdoororwindowisdarkerincolor,youmaychoosetousetheBROWNcoverforthesensorandtheBROWNplasticsforthemagnet.

MAXGAP:5/8”IMPORTANT: Theedgeofthemagnetmustalignwiththelineonthesensor,ANDthemagnetmustlocate

nexttothearrowonthesensor.Maximumgapbetweenthemagnetandthesensoris5/8”.

Ifthemagnetisnotlocatedfollowingtheserules,thesensormaynotgetactivated.

Page 5: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

WhatisZ-Wave?

TheZ-Waveprotocolisaninteroperable,wireless,RF-basedcommunicationstechnologydesignedspecificallyforcontrol,monitoringandstatusreadingapplicationsinresidentialandlightcommercialenvironments.Mature,provenandbroadlydeployed(withover35millionproductssoldworldwide),Z-Waveisbyfartheworldmarketleaderinwirelesscontrol,bringingaffordable,reliableandeasy-to-use'smart'productstomanymillionsofpeopleineveryaspectofdailylife.CertifiedZ-WavedevicesregardlessofmanufacturercanworktogethertoformaZ-Wavemeshnetwork.AlwaysonZ-Wavedevicescanactasrepeatersinthemeshincreasingrangeandredundancy.

ForamorecompletelookatZ-Wavetechnologyfornon-technologists,andtolearnmoreaboutZ-Wave'sroleasakeyenablingtechnologyfortheInternetofThingsandconnectedobjects,pleasevisitwww.z-wave.com.

Z-WaveDeviceClassandCommandClassInformation

ThisZ-WavesensorisaZ-WavegenericDeviceClassofGENERIC_TYPE_SENSOR_NOTIFICATION,andaspecificdeviceclassofSPECIFIC_TYPE_NOTIFICATION_SENSOR,andthesupportedcommandclassesareCOMMAND_CLASS_ZWAVEPLUS_INFO,COMMAND_CLASS_VERSION,COMMAND_CLASS_MANUFACTURER_SPECIFIC,COMMAND_CLASS_POWERLEVEL,COMMAND_CLASS_BATTERY,COMMAND_CLASS_NOTIFICATION_V4,COMMAND_CLASS_ASSOCIATION,COMMAND_CLASS_ASSOCIATION_GRP_INFO,COMMAND_CLASS_WAKE_UP,COMMAND_CLASS_SENSOR_BINARY,COMMAND_CLASS_CONFIGURATION,COMMAND_CLASS_BASIC.

ManufacturerSpecific

ManufacturerID:0x014A

ProductType:4

ProductID:2

FactoryDefault

Torestorethissensortofactorydefaultsettings,followtheinstructionsinthismanualtoexcludethissensorfromtheZ-Wavenetwork.Uponcompletionofremovalfromthenetworkthesensorwillrestoreitselftofactorydefaultsettingsautomatically.Usethisprocedureonlyintheeventthatthenetworkprimarycontrollerismissingorotherwiseinoperable.

KeepingAwakeforTestingandConfiguration

Tosavepower,thissensorsleepsmostofthetimeandisthereforenotawaketoreceivemessagesfromagatewayfortesting.Removingthetopcasefromthesensorwillputindeviceintoatamperedmodeinwhichthesensorwillstayawakeandabletoreceivemessages.Mostofthetimeanenduserwouldnotdothis,butifthesensorneedstobeconfiguredafterinclusion,anendusercanfollowtheinstructionsbelowforsendingWake-Upnotifications.

Page 6: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

Association

ThissensorhastwoAssociationgroupsof5nodeseach.Grouponeisalifelinegroupwhowillreceiveunsolicitedmessagesrelatingtodoor/windowopen/closenotifications,casetamperingnotifications,low-batterynotifications,andsensorbinaryreports.Group2isintendedfordevicesthataretobecontrolledi.e.turnedonoroff(ononlybydefault)withaBasicSet.OninclusionthecontrollershouldputitsnodeIDingroup1butnotgroup2.

NetworkWideInclusion

ThissensoralsosupportsNetworkWideInclusionsuchthattheSensorcanbeincludedintotheZ-Wavenetworkoverthemeshnetworkandnotdirectlynearthemaincontroller.Thismodeisautomaticallyactivatedafterregularinclusionwasnotsuccessful

Page 7: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

SENSORCONDITION

COMMANDCLASSandVALUE ASSOCIATIONGROUP CONFIGURABLE?

Door/WindowOpen

NotificationReportofAccessControl(0x06),Door/Windowisopen(0x16)

1

YesviaNotificationSetofnotificationType(0x06)andstatusof0x00:Thistypeof

notificationturnedoff0xFF:Thistypeofnotificationturnedon

SensorBinaryReportof0xFFSensorType:0xFF

1

YesviaConfigurationCommandClassParameterNumber:2Size:1AConfigurationValue:0xFF(On)/0x00(Off)

Basicsetof0xFF(On) 2 No

Door/WindowClose

NotificationReportofAccessControl(0x06),Door/Windowisclosed(0x17)

1

YesviaNotificationSetofnotificationType(0x06)andstatusof0x00:Thistypeof

notificationturnedoff0xFF:Thistypeofnotificationturnedon

SensorBinaryReportof0x00SensorType:0xFF

1

YesviaConfigurationCommandClassParameterNumber:2Size:1AConfigurationValue:0xFF(On)/0x00(Off)

BasicSetof0x00(Off)ByfactorydefaultthisfeatureisdisabledandmustbeenabledviaConfiguration

CommandClass.

2 YesviaConfigurationCommandClassParameterNumber:1Size:1AConfigurationValue:0xFF(On)/0x00(Off)ParameterNumber:2

SensorCaseRemoved

NotificationReportofHomeSecurity(0x07),Tamperingproductcover

removed(0x03)

1

YesviaNotificationSetofnotificationType(0x07)andstatusof0x00:Thistypeof

notificationturnedoff0xFF:Thistypeofnotificationturnedon

SensorCaseFastened Wake-UpNotification 1 YesviaWake-UpNotificationCommandClass

BatteryLevelDippedBelow2.6v NotificationReportofPowerManagement(0x08),Replacebattery

now(0x0B)

1

YesviaNotificationSetofnotificationType(0x08)andstatusof0x00:Thistypeof

notificationturnedoff0xFF:Thistypeofnotificationturnedon

Page 8: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

Wake-UpNotification

ThesensorwillwakeupeverysooftenandwhenthecaseisclosedtosendaWake-UpNotificationtoallowthelifelinemasternodecontrollerthatthesensorisnowavailableforanyqueuedmessagesthatthecontrollermayhaveforthesensor.ThetimebetweenWake-UpNotificationscanbeconfiguredwiththeWake-UpNotificationcommandclasstobebetween1hourand1weekwithintervalstepsof200seconds.

Configuration

Thesensorhastwoconfigurationparameters.Parameter1configuresthesensortosendornotsendBasicSetcommandsof0x00tonodesinAssociationgroup2turningthedevicesoffwhenthesensorisinarestoredstatei.e.thedoorisclosed.BydefaultthesensordoesNOTsendBasicSetcommandsof0x00.Parameter2configuresthesensortoeithertosendornottosendSensorBinaryReportcommandstoAssociationGroup1whenthesensorisfaultedandrestored.IfthecontrollerisfullycompatiblewiththeNotificationCommandClasstherebymakingtheSensorBinaryReportsredundant,thecontrollercandisabletheSensorBinaryReportCommandscompletely.Thefollowingtableshowsthevaluestoenableanddisablethetwoconfigurationparameters.

ConfigurationSetValues EffectParameterNumber:1Size:1ConfigurationValue:0x00

(Default)SensordoesNOTsendBasicSetstoNodeIDsinAssociationGroup2whenthesensorisrestored(i.e.Door/WindowClosed).

ParameterNumber:1Size:1ConfigurationValue:0xFF

SensorsendsBasicSetsof0x00tonodesinAssociationGroup2whensensorisrestored.

ParameterNumber:2Size:1ConfigurationValue:0x00

(Default)SensorsendsSensorBinaryReportswhensensorisfaultedandrestoredforbackwardscompatibilityinadditiontoNotificationReports.

ParameterNumber:2Size:1ConfigurationValue:0xFF

SensorwillsendonlyNotificationReportsandNOTSensorBinaryReportswhenthesensorisfaultedandrestored.

Page 9: Door/Window Sensor Installation Instructions€¦ · © 2015 Ecolink Intelligent Technology Inc. PN DW-ZWAVE2.5 R1.04 Door/Window Sensor Installation Instructions Product Overview

©2015EcolinkIntelligentTechnologyInc. PNDW-ZWAVE2.5R1.04

FCCComplianceStatement

ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforClassBdigitaldevices,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:

• Re-orientorrelocatethereceivingantenna• Increasetheseparationbetweentheequipmentandreceiver• Connecttheequipmenttoanoutletonadifferentcircuitfromthereceiver• Consultthedealeroranexperiencedradio/TVcontractorforhelp.

Warning:ChangesormodificationsnotexpresslyapprovedbyEcolinkIntelligentTechnologyInc.couldvoidtheuser’sauthoritytooperatetheequipment.

ThisdevicecomplieswithIndustryCanadalicense-exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.

C’etappareilestconformelanormed'IndustrieCanadaexemptsdelicenceRSS.Sonfonctionnementestsoumisauxdeuxconditionssuivantes:(1)c’etappareilnepeutpasprovoquerd'interférences,et(2)c’etappareildoitacceptertouteinterférence,ycomprislesinterférencesquipeuventcauserunmauvaisfonctionnementdeladispositif.

FCCID:TBDIC:TBD

Warranty

EcolinkIntelligentTechnologyInc.warrantsthatforaperiodof3yearsfromthedateofpurchasethatthisproductisfreefromdefectsinmaterialandworkmanship.Thiswarrantydoesnotapplytodamagecausedbyshippingorhandling,ordamagecausedbyaccident,abuse,misuse,misapplication,ordinarywear,impropermaintenance,failuretofollowinstructionsorasaresultofanyunauthorizedmodifications.

IfthereisadefectinmaterialsandworkmanshipundernormalusewithinthewarrantyperiodEcolinkIntelligentTechnologyInc.shall,atitsoption,repairorreplacethedefectiveequipmentuponreturnoftheequipmenttotheoriginalpointofpurchase.

Theforegoingwarrantyshallapplyonlytotheoriginalbuyer,andisandshallbeinlieuofanyandallotherwarranties,whetherexpressedorimpliedandofallotherobligationsorliabilitiesonthepartofEcolinkIntelligentTechnologyInc.neitherassumesresponsibilityfor,norauthorizesanyotherpersonpurportingtoactonitsbehalftomodifyortochangethiswarranty,nortoassumeforitanyotherwarrantyorliabilityconcerningthisproduct.ThemaximumliabilityforEcolinkIntelligentTechnologyInc.underallcircumstancesforanywarrantyissueshallbelimitedtoareplacementofthedefectiveproduct.Itisrecommendedthatthecustomerchecktheirequipmentonaregularbasisforproperoperation.

DesignedinCarlsbad,CAwww.discoverecolink.com