Page 1: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

DOSITEC

ENGLISH

Page 2: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

INDEX

1.-GENERAL DESCRIPTION 4

2.-CARRIAGE AND MAINTENANCE 4

3.-TECHNICAL FEATURES 5

4.-OPERATION 6

5.- INSTALLATION 7Generalities 7Hydraulic connection 7Electric connection 9

6.- START UP 10DOSITEC - MP 12DOSITEC - MD 13DOSITEC - mA 14DOSITEC - Q 17

DOSITEC - PRC 20DOSITEC - MF 28

7.- MAINTENANCE List of parts 39

C.E APPROVAL DECLARATION 42

WARRANTY 42

SAFETY RULES

To avoid personal or environmental damages and to guarantee a proper operation of the equipment, the staff in charge of the installation, set up and maintenance of the equipment must follow the instructions of this manual, specially recommendations and warnings explicitly detailed. In additon, specific instructions for the chemical products to be dosed should be followed.

Page 3: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

INDEX

1.-GENERAL DESCRIPTION 4

2.-CARRIAGE AND MAINTENANCE 4

3.-TECHNICAL FEATURES 5

4.-OPERATION 6

5.- INSTALLATION 7Generalities 7Hydraulic connection 7Electric connection 9

6.- START UP 10DOSITEC - MP 12DOSITEC - MD 13DOSITEC - mA 14DOSITEC - Q 17

DOSITEC - PRC 20DOSITEC - MF 28

7.- MAINTENANCE List of parts 39

C.E APPROVAL DECLARATION 42

WARRANTY 42

SAFETY RULES

To avoid personal or environmental damages and to guarantee a proper operation of the equipment, the staff in charge of the installation, set up and maintenance of the equipment must follow the instructions of this manual, specially recommendations and warnings explicitly detailed. In additon, specific instructions for the chemical products to be dosed should be followed.

Page 4: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

1.- GENERAL DESCRIPTION

The dosing pumps DOSITEC are heavy duty, high precission, electric diaphragm pumps for dosing liquid products.

DOSITEC models:DOSITEC -MP: Manual Regulation from 0 to100% by potentiometerDOSITEC -MD: Manual Regulation from 0 to100% by keyboardDOSITEC - Q: Proportional regulationDOSITEC - mA: Analogic regulation by a current signalDOSITEC - PRC: Control PH or ORP(Redox)DOSITEC - MF: Multifuntion (Manual flow regulation / proportinonal /

Analogical 4-20mA / with timer)

DOSITEC dosing pumps are manufactured with materials that can resist most chemicals products, even acids. They are designed for all sorts of processes where it is necessary to dose a product into a hydraulic network, such as: food, textile, chemical industry, water treatments, etc. (See materials in Technical Features). In case there is any doubt about compatibility of materials with the products to be used please contact ITC S.L. Technical Service.

The metering pump has been designed to feed liquids with capacities from 0 to 20 l/h and pressures from 0 to 10 bar. They also include a conexion for a level switch..

2.- CARRIAGE AND MAINTENANCE

The original packing is thought so that the transport and the storage of the team can be made without causing damages to the team, provided they are made inside dry, aired spaces and far from sources of heat, always maintaining the bomb in vertical position.

Inside the packing it is included:

Dosing pump.1 semirigid PE hose, white, lenght 2m. 2 Flexible PVC hose transparent crystal type, lenght 2m.Injection valve 3/8” BSP-MFiltermanual of instructions

4

3.- TECHNICAL FEATURES

Maximum suction high: 2 mMínimum injection pressure: 0,5 bar

The products are manufactured according CE regulation.• IP 65 protection.• Plastic housing: Polypropylene.• Working temperature: 5-40 ºC• Standard power supply: 230 V (+/-10%) a.c.50 / 60 Hz single phase.• Optional power supply:120 V a.c. 50 / 60 Hz single phase. / 12V d.c.

LIQUID ENDS MATERIALS:

DIAPHRAGM: PTFE.PUMP HEAD: PVDFNIPPLES: PVDF.VÁLVES BODY: PVDFVALVES BALL: CeramicO-RINGS: FPM ( available in EPDM)SUCTION HOSE: PVC flexible.DISCHARGE HOSE : Polyethylene.FILTER: Polypropylene

FLOW-PRESSURE

bar2 64 8 10

l/h

10

6

2

14

12 1614 18 20

12

8

4

16

1 53 7 9 11 1513 17 19

9 l/h@10 bar

6 l/h@ 7 bar

2 l/h@ 20 bar

2,5 l/h@ 10 bar

5

Flowl/h2.5269

2.56

C/min

120120120120120120

Pressure

Bar10207

10107

Stroke length mm

0.81.01.01.40.81.0

PowerWatts

37 (0.16A)

58 (0.25A)

37 (0.16A)

58 (0.25A)

24 (2 A)

24 (2 A)

Power supply Volts

230V AC230V AC230V AC230V AC12V DC12V DC

WeightKg

33.83

3.833

Volumml/cycle

0.350.280.831.250.350.83

Page 5: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

1.- GENERAL DESCRIPTION

The dosing pumps DOSITEC are heavy duty, high precission, electric diaphragm pumps for dosing liquid products.

DOSITEC models:DOSITEC -MP: Manual Regulation from 0 to100% by potentiometerDOSITEC -MD: Manual Regulation from 0 to100% by keyboardDOSITEC - Q: Proportional regulationDOSITEC - mA: Analogic regulation by a current signalDOSITEC - PRC: Control PH or ORP(Redox)DOSITEC - MF: Multifuntion (Manual flow regulation / proportinonal /

Analogical 4-20mA / with timer)

DOSITEC dosing pumps are manufactured with materials that can resist most chemicals products, even acids. They are designed for all sorts of processes where it is necessary to dose a product into a hydraulic network, such as: food, textile, chemical industry, water treatments, etc. (See materials in Technical Features). In case there is any doubt about compatibility of materials with the products to be used please contact ITC S.L. Technical Service.

The metering pump has been designed to feed liquids with capacities from 0 to 20 l/h and pressures from 0 to 10 bar. They also include a conexion for a level switch..

2.- CARRIAGE AND MAINTENANCE

The original packing is thought so that the transport and the storage of the team can be made without causing damages to the team, provided they are made inside dry, aired spaces and far from sources of heat, always maintaining the bomb in vertical position.

Inside the packing it is included:

Dosing pump.1 semirigid PE hose, white, lenght 2m. 2 Flexible PVC hose transparent crystal type, lenght 2m.Injection valve 3/8” BSP-MFiltermanual of instructions

4

3.- TECHNICAL FEATURES

Maximum suction high: 2 mMínimum injection pressure: 0,5 bar

The products are manufactured according CE regulation.• IP 65 protection.• Plastic housing: Polypropylene.• Working temperature: 5-40 ºC• Standard power supply: 230 V (+/-10%) a.c.50 / 60 Hz single phase.• Optional power supply:120 V a.c. 50 / 60 Hz single phase. / 12V d.c.

LIQUID ENDS MATERIALS:

DIAPHRAGM: PTFE.PUMP HEAD: PVDFNIPPLES: PVDF.VÁLVES BODY: PVDFVALVES BALL: CeramicO-RINGS: FPM ( available in EPDM)SUCTION HOSE: PVC flexible.DISCHARGE HOSE : Polyethylene.FILTER: Polypropylene

FLOW-PRESSURE

bar2 64 8 10

l/h

10

6

2

14

12 1614 18 20

12

8

4

16

1 53 7 9 11 1513 17 19

9 l/h@10 bar

6 l/h@ 7 bar

2 l/h@ 20 bar

2,5 l/h@ 10 bar

5

Flowl/h2.5269

2.56

C/min

120120120120120120

Pressure

Bar10207

10107

Stroke length mm

0.81.01.01.40.81.0

PowerWatts

37 (0.16A)

58 (0.25A)

37 (0.16A)

58 (0.25A)

24 (2 A)

24 (2 A)

Power supply Volts

230V AC230V AC230V AC230V AC12V DC12V DC

WeightKg

33.83

3.833

Volumml/cycle

0.350.280.831.250.350.83

Page 6: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

130

100

5

172

4.- OPERATION

6

The metering pump is activated by a PTFE diaphragm mounted on a piston of an electromagnet.

When the piston of the electromagnet is attracted, a pressure is produced in the pump body with an expulsion of liquid from the discharge valve.Once the electric impulse is finished a spring brings the piston back to the initial position, with a recall of liquid through the suction valve.

As the operation is simple the pump does not need lubrication, therefore maintenance is reduced almost to zero.

The materials used for the construction of the pump make it particularly suitable for aggressive liquids.

DIMENSIONES

190

210

5.- INSTALATIÓN

GENERAL

7

HYDRAULIC CONNECTION

Properly design either in the suction and injection pipe is required, avoiding long lenght and bending pipes as much as possible.t

1

6

4

3

2

1

3

2

4

5

6

1

2

3

4

5

6PRIMING VALVE INJECTION VALVE

SUCTION PIPE COUNTER-PRESSURE VALVE

SUCTION FILTER INJECTION PIPE

Install the pump in a dry place and well away from sources of heat and, in any case, at environmental temperatures not exceeding 40°C. The minimum operating temperature depends on the liquid to be pumped,bearing in mind that it must always remain in a liquid state.

Carefully observe the regulations in force in the various countries as regards electrical installations.When the supply cable is devoid of a plug, the equipment should be connected to the supply mains by means of a single-pole circuit breaker having a minimum distance of 3 mm between the contacts. Before accessing any of the electrical parts, make sure that all the supply circuits are open.

Page 7: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

130

100

5

172

4.- OPERATION

6

The metering pump is activated by a PTFE diaphragm mounted on a piston of an electromagnet.

When the piston of the electromagnet is attracted, a pressure is produced in the pump body with an expulsion of liquid from the discharge valve.Once the electric impulse is finished a spring brings the piston back to the initial position, with a recall of liquid through the suction valve.

As the operation is simple the pump does not need lubrication, therefore maintenance is reduced almost to zero.

The materials used for the construction of the pump make it particularly suitable for aggressive liquids.

DIMENSIONES

190

210

5.- INSTALATIÓN

GENERAL

7

HYDRAULIC CONNECTION

Properly design either in the suction and injection pipe is required, avoiding long lenght and bending pipes as much as possible.t

1

6

4

3

2

1

3

2

4

5

6

1

2

3

4

5

6PRIMING VALVE INJECTION VALVE

SUCTION PIPE COUNTER-PRESSURE VALVE

SUCTION FILTER INJECTION PIPE

Install the pump in a dry place and well away from sources of heat and, in any case, at environmental temperatures not exceeding 40°C. The minimum operating temperature depends on the liquid to be pumped,bearing in mind that it must always remain in a liquid state.

Carefully observe the regulations in force in the various countries as regards electrical installations.When the supply cable is devoid of a plug, the equipment should be connected to the supply mains by means of a single-pole circuit breaker having a minimum distance of 3 mm between the contacts. Before accessing any of the electrical parts, make sure that all the supply circuits are open.

Page 8: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

8

PRIMINGVALVE

PRIMINGHOSE

Select the most appropiate injection point in the pipe to inject the product, and place there a 3/8” part to connect the Injection valve

INJECTIONHOSE

3/8”

To prime the pump, first connect the priming hose to the priming valve and drive the other side of the hose to a safety place to pour the air mixed with product.

Open the priming valve and start the pump at maximum flow until having only liquid in the priming outlet

Install a safety valve in a derivation as near as possible from the pump , in order to protect it and the wholeinstallation from possible over-pressures. This derivationMust derive the liquid to a safe place.

B C D

9

ELECTRIC CONNECTION

L1 (BLUE)L2 (BROWN)

YELLOW/GREEN

230V AC

1- 2-3- Pulse Input (+)4- Pulse Input (-)

1- Output relay.AL3. NO 2-3- Output relay (Com)4-

1- 2-3- Signal mA (+)4- Signal mA (-)

1- 2-3- Level switch4- Level switch

The electric protection of the motor must be installed and adjusted following its nominal intensity (overloaded switch disjuntor).

A disconnection dispositive must be installed in case of emergency.

The equipment must be protected to avoid untimely sudden starts.

1- 2-3- Level switch4- Level switch

1- Output mA (+)2- Output mA (-)3- Level switch4- Level switch

1- Pt1002- Pt1000 3- Common Pt1004- Common Pt1000

Connector BNCElectrode pHElectrode ORP (redox)

A

E

1- Output relay NO 2- Output relay NC 3- Output relay (Com)4-

1- 2-3- Level switch4- Level switch

MD Q mA PRC

1

2 3

4

A

B

C

D

E

1

2 3

4

1

2 3

4

1

2 3

4

MF

Output RS2321- Transmition2- Reception3- Ground4- Reset

1- Flow sensor2- Flow sensor3- Level switch (remote)4- Level switch (remote)

1- Output relay NO 2- Output relay NC 3- Output relay (Com)4-

1- 2- Signal Input mA (-)3- Pulse Input (+)4- Pulse Input (-)

Signal Input mA (+)

1 2 3 4

Page 9: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

8

PRIMINGVALVE

PRIMINGHOSE

Select the most appropiate injection point in the pipe to inject the product, and place there a 3/8” part to connect the Injection valve

INJECTIONHOSE

3/8”

To prime the pump, first connect the priming hose to the priming valve and drive the other side of the hose to a safety place to pour the air mixed with product.

Open the priming valve and start the pump at maximum flow until having only liquid in the priming outlet

Install a safety valve in a derivation as near as possible from the pump , in order to protect it and the wholeinstallation from possible over-pressures. This derivationMust derive the liquid to a safe place.

B C D

9

ELECTRIC CONNECTION

L1 (BLUE)L2 (BROWN)

YELLOW/GREEN

230V AC

1- 2-3- Pulse Input (+)4- Pulse Input (-)

1- Output relay.AL3. NO 2-3- Output relay (Com)4-

1- 2-3- Signal mA (+)4- Signal mA (-)

1- 2-3- Level switch4- Level switch

The electric protection of the motor must be installed and adjusted following its nominal intensity (overloaded switch disjuntor).

A disconnection dispositive must be installed in case of emergency.

The equipment must be protected to avoid untimely sudden starts.

1- 2-3- Level switch4- Level switch

1- Output mA (+)2- Output mA (-)3- Level switch4- Level switch

1- Pt1002- Pt1000 3- Common Pt1004- Common Pt1000

Connector BNCElectrode pHElectrode ORP (redox)

A

E

1- Output relay NO 2- Output relay NC 3- Output relay (Com)4-

1- 2-3- Level switch4- Level switch

MD Q mA PRC

1

2 3

4

A

B

C

D

E

1

2 3

4

1

2 3

4

1

2 3

4

MF

Output RS2321- Transmition2- Reception3- Ground4- Reset

1- Flow sensor2- Flow sensor3- Level switch (remote)4- Level switch (remote)

1- Output relay NO 2- Output relay NC 3- Output relay (Com)4-

1- 2- Signal Input mA (-)3- Pulse Input (+)4- Pulse Input (-)

Signal Input mA (+)

1 2 3 4

Page 10: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

10

6.- START UP AND REGULATION

STAND: Check that the pump is properly installed in its stand.

CHECKING OF HYDRAULIC CIRCUIT: Check that all valves are opened and that escapes from priming valves derive the liquid to a proper receptacle

CHECKING OF PUMP: Check visually/auditorilly the proper working of the pump.

OVER-PRESSURE PROTECTION: Adjust the safety valve over-pressure or relief to the wished pressure to protect the installation without exceeding the pump nominal pressure.

ELECTRIC PROTECTION: Adjust the electric dispositive of electric

In this case it is essential to bear in mind the following:

Replace PVC crystal suction hose with polyethilene discharge hose.

Empty any residual water from the pump head beforehand.

Warning: if the water mixes with sulphuric acid it can produce a large quantity of gas with consequent overheating of the area causing damage to valves and pump head.This operation can also be done with the pump disconnected from the plant by turning the pump upside-down for 15 to 30 seconds and without connecting the hose to the nipples; if impossible, dismount and remount the pump head using the four mounting screws.

HOW TO OPERATE WHEN DOSING SULPHURIC ACID

11

HOW TO OPERATE WHEN DOSING SODIUM HYPOCLORITE

Disconnect the pins from the mains or by means of a onnipolar switch with 3 mm minimum distance between the contact.

Disconnect discharge hose from process plant.

Remove the suction hose (with filter) from the tank and dip it into clean water.

Switch on the metering pump and let it operate with water for 5 to 10 minutes.

Switch OFF the pump, dip the filter into a hydrochloric acid solution and wait until the acid finishes cleaning.

Switch ON the pump again and operate it with hydrochloric acid for 5 minutes in a closed-circuit, with suction and discharge hose dipped into the same tank.

Repeat the operation with water.

Re-connect the metering pump to the process plant.

Page 11: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

10

6.- START UP AND REGULATION

STAND: Check that the pump is properly installed in its stand.

CHECKING OF HYDRAULIC CIRCUIT: Check that all valves are opened and that escapes from priming valves derive the liquid to a proper receptacle

CHECKING OF PUMP: Check visually/auditorilly the proper working of the pump.

OVER-PRESSURE PROTECTION: Adjust the safety valve over-pressure or relief to the wished pressure to protect the installation without exceeding the pump nominal pressure.

ELECTRIC PROTECTION: Adjust the electric dispositive of electric

In this case it is essential to bear in mind the following:

Replace PVC crystal suction hose with polyethilene discharge hose.

Empty any residual water from the pump head beforehand.

Warning: if the water mixes with sulphuric acid it can produce a large quantity of gas with consequent overheating of the area causing damage to valves and pump head.This operation can also be done with the pump disconnected from the plant by turning the pump upside-down for 15 to 30 seconds and without connecting the hose to the nipples; if impossible, dismount and remount the pump head using the four mounting screws.

HOW TO OPERATE WHEN DOSING SULPHURIC ACID

11

HOW TO OPERATE WHEN DOSING SODIUM HYPOCLORITE

Disconnect the pins from the mains or by means of a onnipolar switch with 3 mm minimum distance between the contact.

Disconnect discharge hose from process plant.

Remove the suction hose (with filter) from the tank and dip it into clean water.

Switch on the metering pump and let it operate with water for 5 to 10 minutes.

Switch OFF the pump, dip the filter into a hydrochloric acid solution and wait until the acid finishes cleaning.

Switch ON the pump again and operate it with hydrochloric acid for 5 minutes in a closed-circuit, with suction and discharge hose dipped into the same tank.

Repeat the operation with water.

Re-connect the metering pump to the process plant.

Page 12: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

12

DOSITEC MP

MANUAL REGULATION DOSING PUMP

Flow can be controlled manually by setting the pump pulse rate by means of a potentiometer. Possibility of a more precise flow rate setting at low frequencies through the two keys 20% and 100%.

1 3 4 2

5

6

7

8

9

1 START button2 STOP button3 20% flow scale read out button4 100% flow scale read out button5 Adjustment knob of injections/min (0-100%)6 Power LED 7 Pulse LED 8 20% flow scale read out LED9 100% flow scale read out LED

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

13

DOSITEC MD

Flow can be controlled manually by setting the pump pulse rate through the keypad from 0 to 100%.

2 3 1

4

5

6

1 Increasing value button2 Decreasing value button3 START /STOP button4 Display 5 Power LED6 Pulse LED

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

MANUAL REGULATION DOSING PUMP

Page 13: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

12

DOSITEC MP

MANUAL REGULATION DOSING PUMP

Flow can be controlled manually by setting the pump pulse rate by means of a potentiometer. Possibility of a more precise flow rate setting at low frequencies through the two keys 20% and 100%.

1 3 4 2

5

6

7

8

9

1 START button2 STOP button3 20% flow scale read out button4 100% flow scale read out button5 Adjustment knob of injections/min (0-100%)6 Power LED 7 Pulse LED 8 20% flow scale read out LED9 100% flow scale read out LED

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

13

DOSITEC MD

Flow can be controlled manually by setting the pump pulse rate through the keypad from 0 to 100%.

2 3 1

4

5

6

1 Increasing value button2 Decreasing value button3 START /STOP button4 Display 5 Power LED6 Pulse LED

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

MANUAL REGULATION DOSING PUMP

Page 14: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

14

DOSITEC mA

ANALOGIC 4-20mA DOSING PUMP

Microcontrolled dosing pump with a 4-20mA input for the flow regulation.

6 2 3 7

5

13

14

11

1

1 Display selector button (mA / pulse)2 Increasing values button3 Decreasing values button4 Function slection button5 Enter button6 Pulse displaying LED7 Manula function LED 8 LED SET POINT 2 / STOP9 LED SET POINT 1 / STOP10 Meter functionLED 11 mA displaying LED 12 Display13 Pulse LED 14 Level alarm LED

12 10

4 8 9

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

15

LEVEL CONTROL (UPON REQUEST)If the dosing pump is supplied with level control setting and upon request floating level switch. When the level of the additive is lower than the switch, level alarm goes ON, the display will show "FAO", the pump is off giving an optical and sound alarm. The level control alarm goes ON with 5 seconds delay.

Turning on the pump, the instrument switches automatically to the "METER" function.

Pressing button mA pulse will show the actual mA input signal. To go back to strokes/min press again.

In order to avoid programming and setting errors during the system functioning, the pump is programmed to automatically return to the Meter Mode each time the unit is switched OFF.

Switch to manual function and select a high frequency to prime the pump.

PROGRAMMING

SET POINT 1Mode Set 1 is used to select the mA input value/min. dosing pump flow and pulse frequency.

Press “F” button and Set 1 LED will switch on. The display will show the pulse frequency previously set. Select the minimum pump output required pressing “+/-” buttons. If the minimum output is zero set 000.

Press “mA/pulse” button, “mA” LED will switch on:

By pressing “+/-” buttons, you can select the mA input value corresponding to minimum pump output required.

Confirm with “Enter”.

STARTING THE PUMP

PRIMING

Press the “F” button to switch to MANUA function.Increase or decrease the injection/min through “+ /-” buttons (recomended about 75% of maximum frequency)

Page 15: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

14

DOSITEC mA

ANALOGIC 4-20mA DOSING PUMP

Microcontrolled dosing pump with a 4-20mA input for the flow regulation.

6 2 3 7

5

13

14

11

1

1 Display selector button (mA / pulse)2 Increasing values button3 Decreasing values button4 Function slection button5 Enter button6 Pulse displaying LED7 Manula function LED 8 LED SET POINT 2 / STOP9 LED SET POINT 1 / STOP10 Meter functionLED 11 mA displaying LED 12 Display13 Pulse LED 14 Level alarm LED

12 10

4 8 9

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

15

LEVEL CONTROL (UPON REQUEST)If the dosing pump is supplied with level control setting and upon request floating level switch. When the level of the additive is lower than the switch, level alarm goes ON, the display will show "FAO", the pump is off giving an optical and sound alarm. The level control alarm goes ON with 5 seconds delay.

Turning on the pump, the instrument switches automatically to the "METER" function.

Pressing button mA pulse will show the actual mA input signal. To go back to strokes/min press again.

In order to avoid programming and setting errors during the system functioning, the pump is programmed to automatically return to the Meter Mode each time the unit is switched OFF.

Switch to manual function and select a high frequency to prime the pump.

PROGRAMMING

SET POINT 1Mode Set 1 is used to select the mA input value/min. dosing pump flow and pulse frequency.

Press “F” button and Set 1 LED will switch on. The display will show the pulse frequency previously set. Select the minimum pump output required pressing “+/-” buttons. If the minimum output is zero set 000.

Press “mA/pulse” button, “mA” LED will switch on:

By pressing “+/-” buttons, you can select the mA input value corresponding to minimum pump output required.

Confirm with “Enter”.

STARTING THE PUMP

PRIMING

Press the “F” button to switch to MANUA function.Increase or decrease the injection/min through “+ /-” buttons (recomended about 75% of maximum frequency)

Page 16: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

16

To finish the programming procedure and modify the maximum output value, press “F” button which will automatically change to mode Set 2.

SET POINT 2

Mode Set 2 selects the mA input value/max. dosing pump flow and pulse/frequency.

Press “F” button and Set 2 LED wil switch on, the display will show the frequency previously set.

Press buttons “+/-” to set the desired imp/frequency at the maximum pump output required.

Press button “mA/pulse”, the display will show the value previously set.

Pressing “+/-” select the mA input value at the maximum pump output required.

Press Enter button.

Direct Functioning ModeDuring production the pumps are programmed for a 4-20 mA direct functioning curve. The pump will start every time the mA signal goes above 4 mA increasing the pulse frequency (and consequently the flow) proportionally to the mA input signal up to maximum imp/min frequency available. E.G. Set 1 minimum signal 4 mA, minimum output. Set 2 maximum signal 20 mA, maximum output.

Reverse Functioning ModeReverse functioning is when the mA signal increases and pump output proportionally decreases. Select the maximum mA signal required with mode Set 1 (in relation to the min. output). E.G. Set 1 maximum signal 20 mA, minimum output.Set 2 minimum signal 4 mA, maximum output.

WARNING: Reverse functioning can only be selected when mode Set 1 is always higher than the mA signal.

Example n° 1: DOSITEC-mA, 10 L/H, 5 BAR, SIGNAL 4-20 mA.Signal 4 mA = 0 l/h (0% pump flow rate)Signal 12 mA = 5 l/h (50% pump flow rate)Signal 20 mA = 10 l/h (100% pump flow rate)

Example n° 2: SAME MODEL , BUT WITH INVERSE SIGNAL: 20 - 4 mASignal 4 mA = 10 l/h (100% pump flow rate)Signal 12 mA = 5 l/h (50% pump flow rate)Signal 20 mA = 0 l/h (0% pump flow rate

17

DOSITEC Q

PROPORTIONAL DOSING PUMP

Microcontrolled dosing pump with a water counter input, for a proportional dosing. Possibility to set a proportion between the pulses from the water counter and the pulses of the dosing pump.

1 3 4 2

56

7

8

9

1 Decreasing values button2 Increasing values button3 Function selection button4 START / STOP button5 Display6 Power LED 7 Pulse LED 8 1xN LED / manual function9 1XN (M) LED10 1:N LED

10

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

Page 17: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

16

To finish the programming procedure and modify the maximum output value, press “F” button which will automatically change to mode Set 2.

SET POINT 2

Mode Set 2 selects the mA input value/max. dosing pump flow and pulse/frequency.

Press “F” button and Set 2 LED wil switch on, the display will show the frequency previously set.

Press buttons “+/-” to set the desired imp/frequency at the maximum pump output required.

Press button “mA/pulse”, the display will show the value previously set.

Pressing “+/-” select the mA input value at the maximum pump output required.

Press Enter button.

Direct Functioning ModeDuring production the pumps are programmed for a 4-20 mA direct functioning curve. The pump will start every time the mA signal goes above 4 mA increasing the pulse frequency (and consequently the flow) proportionally to the mA input signal up to maximum imp/min frequency available. E.G. Set 1 minimum signal 4 mA, minimum output. Set 2 maximum signal 20 mA, maximum output.

Reverse Functioning ModeReverse functioning is when the mA signal increases and pump output proportionally decreases. Select the maximum mA signal required with mode Set 1 (in relation to the min. output). E.G. Set 1 maximum signal 20 mA, minimum output.Set 2 minimum signal 4 mA, maximum output.

WARNING: Reverse functioning can only be selected when mode Set 1 is always higher than the mA signal.

Example n° 1: DOSITEC-mA, 10 L/H, 5 BAR, SIGNAL 4-20 mA.Signal 4 mA = 0 l/h (0% pump flow rate)Signal 12 mA = 5 l/h (50% pump flow rate)Signal 20 mA = 10 l/h (100% pump flow rate)

Example n° 2: SAME MODEL , BUT WITH INVERSE SIGNAL: 20 - 4 mASignal 4 mA = 10 l/h (100% pump flow rate)Signal 12 mA = 5 l/h (50% pump flow rate)Signal 20 mA = 0 l/h (0% pump flow rate

17

DOSITEC Q

PROPORTIONAL DOSING PUMP

Microcontrolled dosing pump with a water counter input, for a proportional dosing. Possibility to set a proportion between the pulses from the water counter and the pulses of the dosing pump.

1 3 4 2

56

7

8

9

1 Decreasing values button2 Increasing values button3 Function selection button4 START / STOP button5 Display6 Power LED 7 Pulse LED 8 1xN LED / manual function9 1XN (M) LED10 1:N LED

10

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

Page 18: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

18

LEVEL CONTROL (UPON REQUEST)If the dosing pump is supplied with level control setting and upon request floating level switch. When the level of the additive is lower than the switch, level alarm goes ON, the display will show "FAO", the pump is off giving an optical and sound alarm. The level control alarm goes ON with 5 seconds delay.

PROGRAMMING

MANUAL MODEIn manual mode select the desired injection frequency by pressing the arrow buttons, and starting with the “START/STOP” button.

PROPORCIONAL MODE

2)Select the desired proportion value by pressing buttons.3) Confirm value with button

Note: The injection velocity is selected in the manual mode

1001XN 1XN(M) FC tFF

MANUAL MODE PROPORTIONAL MODE

1XN ModeThe pump is operated by an impulse produced by an external device (e.g. pulse emitting water meter) and it supplies a number of injections equal to the value visualized on the display "N" (set by the operator). In case during the dosing of the "N strokes" other pulses arrive, these are neglected.

Example:- Pump set in water meter 1XN mode- Set value on "20"- At the time the water meter gives a pulse to the pump, it starts its 20 dosing injection strokes, if during this phase further shuts of the contact occur, these are neglected. Ended up the 20 injections, the pump is waiting for further pulses from the water meter to restart the dosing cycle.

1XN (M) MODELike in the 1XN mode but the microprocessor save in its memory all the received pulses.

ExampleThe pump receives the first contact and returns a string "N" injections to the maximum frequency (e.g. 120 imps./min).

To the arrival of the second contact, the pump computes the time "T" spent by the arrival of the first one and it returns a string of "N" injections not more to the maximum frequency but to that it allows to uniformly distribute them in the time "T".

If instead quick contacts goes to the condition N1>4 , the pump goes in alarm(AL3), the pump continues working, b

1:N MODEThe pump supplies an injection of chemical only when it has reached a number of pulses (contacts), equal to the value visualized on the display (set by the operator)

Example::- Pump set in water meter 1XN mode- Set value on "20”- At the time the water meter gives 20 pulses, the pump gives one pulse.

ut will miss the remaining injections.

19

100

1XN(M) FC t

1XN 1 1XN(M) MODE

1XN(M) 1

1:N MODE

1:N 1

FF

FF

4)Starting with the button.

STARTSTOP

1XN(M) FC t1XN 10

1)Select the desired injection frequency by pressing

2)Confirm by

3)Starting with the buttonSTARTSTOP

STARTSTOP

1XN MODEFF

STARTSTOP

1)Select the desired mode

Page 19: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

18

LEVEL CONTROL (UPON REQUEST)If the dosing pump is supplied with level control setting and upon request floating level switch. When the level of the additive is lower than the switch, level alarm goes ON, the display will show "FAO", the pump is off giving an optical and sound alarm. The level control alarm goes ON with 5 seconds delay.

PROGRAMMING

MANUAL MODEIn manual mode select the desired injection frequency by pressing the arrow buttons, and starting with the “START/STOP” button.

PROPORCIONAL MODE

2)Select the desired proportion value by pressing buttons.3) Confirm value with button

Note: The injection velocity is selected in the manual mode

1001XN 1XN(M) FC tFF

MANUAL MODE PROPORTIONAL MODE

1XN ModeThe pump is operated by an impulse produced by an external device (e.g. pulse emitting water meter) and it supplies a number of injections equal to the value visualized on the display "N" (set by the operator). In case during the dosing of the "N strokes" other pulses arrive, these are neglected.

Example:- Pump set in water meter 1XN mode- Set value on "20"- At the time the water meter gives a pulse to the pump, it starts its 20 dosing injection strokes, if during this phase further shuts of the contact occur, these are neglected. Ended up the 20 injections, the pump is waiting for further pulses from the water meter to restart the dosing cycle.

1XN (M) MODELike in the 1XN mode but the microprocessor save in its memory all the received pulses.

ExampleThe pump receives the first contact and returns a string "N" injections to the maximum frequency (e.g. 120 imps./min).

To the arrival of the second contact, the pump computes the time "T" spent by the arrival of the first one and it returns a string of "N" injections not more to the maximum frequency but to that it allows to uniformly distribute them in the time "T".

If instead quick contacts goes to the condition N1>4 , the pump goes in alarm(AL3), the pump continues working, b

1:N MODEThe pump supplies an injection of chemical only when it has reached a number of pulses (contacts), equal to the value visualized on the display (set by the operator)

Example::- Pump set in water meter 1XN mode- Set value on "20”- At the time the water meter gives 20 pulses, the pump gives one pulse.

ut will miss the remaining injections.

19

100

1XN(M) FC t

1XN 1 1XN(M) MODE

1XN(M) 1

1:N MODE

1:N 1

FF

FF

4)Starting with the button.

STARTSTOP

1XN(M) FC t1XN 10

1)Select the desired injection frequency by pressing

2)Confirm by

3)Starting with the buttonSTARTSTOP

STARTSTOP

1XN MODEFF

STARTSTOP

1)Select the desired mode

Page 20: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

20

DOSITEC PRC

PH, ORP (REDOX) DOSING PUMP

1 3 4 2

67

8

9

5

Microcontrolled dosing pump for PH or ORP(redox) control

1 Decreasing values button2 Increasing values button3 Escape button4 Cursor movement5 Enter button6 LCD display 7 Power LED 8 Pulse LED9 Alarm LED

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

21

DISPLAY DESCRIPTION

OVER Overdosing alarmDELAY Delay at powering onSET POINT Set point settingLEVEL Level alarmALARM Alarms settingMENU Menu selectionON-OFF ON-OFF functioning modePROP Proportional functioning modeHYST Hysteresis setting12 Calibration pointsCALIB Calibration menuSETUP General instrument settingSTARTUP Switching on delay settingINPUT MODE Level probe/flow sensor input activationRESET Reset activationDIRECTION Intervention selectionMAX Maximum pulses frequency based to maximum measuring value4 20 mA Output current settingsh:m:s Hours:minutes:secondsPH pH measureRx mV measure% Flow rate percentage

Password settingIntervention Alkaline/Oxidant/DirectaIntervention Acid/Reductive/Inversepulses/minuteFlow sensorNumeric values visualization

Page 21: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

20

DOSITEC PRC

PH, ORP (REDOX) DOSING PUMP

1 3 4 2

67

8

9

5

Microcontrolled dosing pump for PH or ORP(redox) control

1 Decreasing values button2 Increasing values button3 Escape button4 Cursor movement5 Enter button6 LCD display 7 Power LED 8 Pulse LED9 Alarm LED

ACCESSORIES

- 1 flexible transparent PVC suction hose 2m- 1 semirig white PE injection hose 2m- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose.

21

DISPLAY DESCRIPTION

OVER Overdosing alarmDELAY Delay at powering onSET POINT Set point settingLEVEL Level alarmALARM Alarms settingMENU Menu selectionON-OFF ON-OFF functioning modePROP Proportional functioning modeHYST Hysteresis setting12 Calibration pointsCALIB Calibration menuSETUP General instrument settingSTARTUP Switching on delay settingINPUT MODE Level probe/flow sensor input activationRESET Reset activationDIRECTION Intervention selectionMAX Maximum pulses frequency based to maximum measuring value4 20 mA Output current settingsh:m:s Hours:minutes:secondsPH pH measureRx mV measure% Flow rate percentage

Password settingIntervention Alkaline/Oxidant/DirectaIntervention Acid/Reductive/Inversepulses/minuteFlow sensorNumeric values visualization

Page 22: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

22

PARAMETERS AND FUNCTIONS LAYOUT

Selection measures to control pHSetpoint setting 7.2Hysteresis setting 0.1Choice of the type of intervention AcidON/OFF or Proportional intervention selection ON-OFFDefinition of beginning intervention value”PROP” Setpoint+1pHFirst point of calibration procedure ---Second point of calibration procedure ---Minimum alarm point 0.00Maximum alarm point 14.00Over-dosing alarm value 02:00 (h:m)Choise of the type of menu: BASE / FULL BASESix figures numerical pasword DisableDelay at powering on 00:03 (m:s)Delay exit calibration menu 05:00 (m:s)Calibration check 4 mA 4 mACalibration check 20 mA 20 mA

TYPICAL CHARACTERISTICS

Temperature 0-40ºCMax. Current relay output 6A (resisitve load) 1A ( inductive load)Current output 4-20mA (dynamic 0-500Ohm)PH measure 0-14 (0.01 pH) ORP (mV) mesure -1000 - +1400 (+/-1mV)

LEVEL CONTROL

PROGRAMATION

Press to enter in menus, and press you will scroll all 4 menus:

SETUP menu press to reach the desired menu BASE / FULL

Press to change the parameters of setup:

On the display will appear the set measure type pH or mV Change by means “+/-” and confirm through “ENT”:

DOSITEC PRC is supplied with level control setting.When the chemical tank is empty, on the display will appear LEVEL and the pump goes in stand by. The level control has 5 seconds of delay.

The first operation to do is to select the type of parameter (pH or Redox) that is intends to measure and to control.

The pump has turned on, on display it appears software revision then the type of controlled parameter that it flashes (default setting pH)Set measure type by means on the “+/-” and confirm through “ENT”

On display will show the measure's value.

23

ENT

SETUP

pH

pH

7.10

MENUSETPOINT

MENU

SETUP

MENU

CALIB

MENU

ALARM

MENU

SETUP

MENU

SETUP base

MENU

SETUP fullENT

SETUP

pH

ENT

Page 23: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

22

PARAMETERS AND FUNCTIONS LAYOUT

Selection measures to control pHSetpoint setting 7.2Hysteresis setting 0.1Choice of the type of intervention AcidON/OFF or Proportional intervention selection ON-OFFDefinition of beginning intervention value”PROP” Setpoint+1pHFirst point of calibration procedure ---Second point of calibration procedure ---Minimum alarm point 0.00Maximum alarm point 14.00Over-dosing alarm value 02:00 (h:m)Choise of the type of menu: BASE / FULL BASESix figures numerical pasword DisableDelay at powering on 00:03 (m:s)Delay exit calibration menu 05:00 (m:s)Calibration check 4 mA 4 mACalibration check 20 mA 20 mA

TYPICAL CHARACTERISTICS

Temperature 0-40ºCMax. Current relay output 6A (resisitve load) 1A ( inductive load)Current output 4-20mA (dynamic 0-500Ohm)PH measure 0-14 (0.01 pH) ORP (mV) mesure -1000 - +1400 (+/-1mV)

LEVEL CONTROL

PROGRAMATION

Press to enter in menus, and press you will scroll all 4 menus:

SETUP menu press to reach the desired menu BASE / FULL

Press to change the parameters of setup:

On the display will appear the set measure type pH or mV Change by means “+/-” and confirm through “ENT”:

DOSITEC PRC is supplied with level control setting.When the chemical tank is empty, on the display will appear LEVEL and the pump goes in stand by. The level control has 5 seconds of delay.

The first operation to do is to select the type of parameter (pH or Redox) that is intends to measure and to control.

The pump has turned on, on display it appears software revision then the type of controlled parameter that it flashes (default setting pH)Set measure type by means on the “+/-” and confirm through “ENT”

On display will show the measure's value.

23

ENT

SETUP

pH

pH

7.10

MENUSETPOINT

MENU

SETUP

MENU

CALIB

MENU

ALARM

MENU

SETUP

MENU

SETUP base

MENU

SETUP fullENT

SETUP

pH

ENT

Page 24: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

24

ENT

Will appear the protection password.OFF: password dissable

To enable the pasword mode press “+ / -” Set a password through “+/-” to increase or decrease value. Change digit through right arrow. Press “ENT”to confirm the password

After the password has been determined, it is possible to set up the type of sensor that is necessary to install the pump: When a level sensor is needed to be connected, the LEVEL warning will appear, when is necessary to connect a proximity sensor this icon will appear

On the display will appear the menu to select the time the pump will use to quite from calibration phase setting to come back to the main measuring display.Press ”+/-” to set the delay time and confirm with “ENT”

On the display will appear to set the delay time from pump switching-onPress “+/-” for change the time and “ENT” to confirm.

To solve the problem of inertia of someone electrodes or plant installation, the pump has the possibility to set de delay time from pump switching-on to the measuring and control moment.

CALIBRATION menu press set calibration

PH calibration:On the display will appear “POINT 1” Put the electrode in buffer solution pH7Adjust the value on the display up to reach 7.00 with “+/-” and press “ENT” to confirm

On the display will appear “POINT 2” Put the electrode after washing with tap water in the second buffer solution 4.00 or 9.00 pH Adjust the value on the display up to reach 4.00 or 9.00 with “+/-” and press “ENT” to confirm

MENU

SETUP offMENU

SETUP oooo

INPUT MODE

LEVEL

MENU

CALIB

DELAY h:m:s

10:00

DELAY h:m:sSTARTUP

00:03

MENU

CALIB

CALIB

pH

7.001POINT

CALIB

pH

4.002POINT

ORP (redox) calibration:POINT 1: put in short circuit the BNC connector . Using a metal wire, connected the core pin with the external cylinder part.Adjust the value on the display up to reach 0 using “+/-” and press “ENT” to confirm.Point 2: put the electrode in buffer solution (250, 475,650 mV)Adjust the value on the display up to reach the buffer solution value using “+/-” and press “ENT” to confirm.

SETPOINT menu press to change the set point

On display will appear the set point valueAdjust using “+/-”, and press “ENT” to confirm

On display will appear the menu to set if the pump has to dose above the set point or bellow this valueFor dosing an acid chemical select ” “ and for dosing alkaline chemical select “ “

Select with ”+/-” and press “ENT” to confirm

On display will appear the “HYSTERESIS” menu (only with ”FULL” menu) , this is the distance from the set point value, over this value the pump starts or stops it`s dosing Press ”+/-” to set the value and confirm with “ENT”

On display will appear to select the regulation mode:ON-OFF- when the pump has to dose it will run at flow rate selected by the user in Flow rate setting , and iit stops at the Setpoint.

PROP- when the pump will dose proportionality to the set point value. The pump star dosing over setpoint , increasing it’s speed up to the max frequency adjustment use will set.Press ”+/-” to select and confirm with “ENT”

25

MENUSETPOINT

ENT

SET pH

7.50POINT

SET

DIRECTION

POINT

HYST

0.05POINTSET

pH

MODE

SET

ON-OFF

POINT

MODE

SET

PROP.

POINT

Page 25: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

24

ENT

Will appear the protection password.OFF: password dissable

To enable the pasword mode press “+ / -” Set a password through “+/-” to increase or decrease value. Change digit through right arrow. Press “ENT”to confirm the password

After the password has been determined, it is possible to set up the type of sensor that is necessary to install the pump: When a level sensor is needed to be connected, the LEVEL warning will appear, when is necessary to connect a proximity sensor this icon will appear

On the display will appear the menu to select the time the pump will use to quite from calibration phase setting to come back to the main measuring display.Press ”+/-” to set the delay time and confirm with “ENT”

On the display will appear to set the delay time from pump switching-onPress “+/-” for change the time and “ENT” to confirm.

To solve the problem of inertia of someone electrodes or plant installation, the pump has the possibility to set de delay time from pump switching-on to the measuring and control moment.

CALIBRATION menu press set calibration

PH calibration:On the display will appear “POINT 1” Put the electrode in buffer solution pH7Adjust the value on the display up to reach 7.00 with “+/-” and press “ENT” to confirm

On the display will appear “POINT 2” Put the electrode after washing with tap water in the second buffer solution 4.00 or 9.00 pH Adjust the value on the display up to reach 4.00 or 9.00 with “+/-” and press “ENT” to confirm

MENU

SETUP offMENU

SETUP oooo

INPUT MODE

LEVEL

MENU

CALIB

DELAY h:m:s

10:00

DELAY h:m:sSTARTUP

00:03

MENU

CALIB

CALIB

pH

7.001POINT

CALIB

pH

4.002POINT

ORP (redox) calibration:POINT 1: put in short circuit the BNC connector . Using a metal wire, connected the core pin with the external cylinder part.Adjust the value on the display up to reach 0 using “+/-” and press “ENT” to confirm.Point 2: put the electrode in buffer solution (250, 475,650 mV)Adjust the value on the display up to reach the buffer solution value using “+/-” and press “ENT” to confirm.

SETPOINT menu press to change the set point

On display will appear the set point valueAdjust using “+/-”, and press “ENT” to confirm

On display will appear the menu to set if the pump has to dose above the set point or bellow this valueFor dosing an acid chemical select ” “ and for dosing alkaline chemical select “ “

Select with ”+/-” and press “ENT” to confirm

On display will appear the “HYSTERESIS” menu (only with ”FULL” menu) , this is the distance from the set point value, over this value the pump starts or stops it`s dosing Press ”+/-” to set the value and confirm with “ENT”

On display will appear to select the regulation mode:ON-OFF- when the pump has to dose it will run at flow rate selected by the user in Flow rate setting , and iit stops at the Setpoint.

PROP- when the pump will dose proportionality to the set point value. The pump star dosing over setpoint , increasing it’s speed up to the max frequency adjustment use will set.Press ”+/-” to select and confirm with “ENT”

25

MENUSETPOINT

ENT

SET pH

7.50POINT

SET

DIRECTION

POINT

HYST

0.05POINTSET

pH

MODE

SET

ON-OFF

POINT

MODE

SET

PROP.

POINT

Page 26: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

2626 27

When select ON-OFF, on the display will appears the maximum frequency adjustmentPress “+/-” to change and “ENT” to confirm

Only in ON-OFF mode it is possible to define the time delay before pump start -up, when going out of the setpoint Press “+/-” to change and “ENT” to confirm

When select PROP, on the display will appear the maximum measure value to which the pump has to dose at the maximum frequencyPress “+/-” to change and confirm with “ENT”

Only in PROP mode, on the display will appear the maximum frequency adjustment corresponding to the previous value.Press “+/-” to change and confirm with “ENT”

Only in PROP mode, on the display will appear frequency adjustment corresponding to the SetpointPress “+/-” to change and confirm with“ENT”

On the display will appear two measurers values that correspond to the 4-20mA outputPress “+/-” to set the value of the measure to which it has to correspond 4mA output, and confirm with “ENT”

Press “+/-” to set the value of the measure to which it has to correspond 20mA output, and confirm with “ENT”

ALARM menu press to enter in alarm mode

On the display will appear the MAXIMUM value of the measure, where the pump has to go in alarm mode.Press “+/-” to set the value and confirm with “ENT”

SET

ON-OFF

100POINT

%

SET

DELAY m:s

00.03POINT

SET 8.20POINT

PROP. MAX

pH

SET 100POINT

%

PROP. MAX

pH

SET 0POINT

%

PROP.

pH

min

SET

4 mA

0.00POINT

pH

SET

20mA

14.00POINT

pH

MENU

ENTALARM

ALARM

pH

MAX

14.00

On the display will appear MINIMUM value of the measure, at which the pump has to go in alarm mode.Press “+/-” to change the value and confirm with “ENT”

On the display will appear OVER DELAY ,which is the maximum time allowed to reach the set point value. Over this time, the pump will go in alarm modePress “+/-” to change the value and confirm with “ENT”. Press “ESC” to return in measure mode

RESET procedure (partial o total)Turn off and turn on the pump

Press press at the same time With this procedure a PARTIAL reset will be actived, the pump return to the default settings but all the calibration will be saved

Press twice then press will appear

With this procedure a TOTAL reset will be actived, the pump return to the default settings and all the calibration parameters will be lost.

Press twice then press will appear

With STANBD-BY procedure, the pump is put on stand by

Hold down at until a same time appears

In order to exit this mode, hold down keys “+ / -” at the same time.

ALARM

pH

min

0.00

ALARMOVER DELAY

pH

h:m

02:00

ENTMENUSETPOINT

RESET

RESET

RESET

Page 27: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

2626 27

When select ON-OFF, on the display will appears the maximum frequency adjustmentPress “+/-” to change and “ENT” to confirm

Only in ON-OFF mode it is possible to define the time delay before pump start -up, when going out of the setpoint Press “+/-” to change and “ENT” to confirm

When select PROP, on the display will appear the maximum measure value to which the pump has to dose at the maximum frequencyPress “+/-” to change and confirm with “ENT”

Only in PROP mode, on the display will appear the maximum frequency adjustment corresponding to the previous value.Press “+/-” to change and confirm with “ENT”

Only in PROP mode, on the display will appear frequency adjustment corresponding to the SetpointPress “+/-” to change and confirm with“ENT”

On the display will appear two measurers values that correspond to the 4-20mA outputPress “+/-” to set the value of the measure to which it has to correspond 4mA output, and confirm with “ENT”

Press “+/-” to set the value of the measure to which it has to correspond 20mA output, and confirm with “ENT”

ALARM menu press to enter in alarm mode

On the display will appear the MAXIMUM value of the measure, where the pump has to go in alarm mode.Press “+/-” to set the value and confirm with “ENT”

SET

ON-OFF

100POINT

%

SET

DELAY m:s

00.03POINT

SET 8.20POINT

PROP. MAX

pH

SET 100POINT

%

PROP. MAX

pH

SET 0POINT

%

PROP.

pH

min

SET

4 mA

0.00POINT

pH

SET

20mA

14.00POINT

pH

MENU

ENTALARM

ALARM

pH

MAX

14.00

On the display will appear MINIMUM value of the measure, at which the pump has to go in alarm mode.Press “+/-” to change the value and confirm with “ENT”

On the display will appear OVER DELAY ,which is the maximum time allowed to reach the set point value. Over this time, the pump will go in alarm modePress “+/-” to change the value and confirm with “ENT”. Press “ESC” to return in measure mode

RESET procedure (partial o total)Turn off and turn on the pump

Press press at the same time With this procedure a PARTIAL reset will be actived, the pump return to the default settings but all the calibration will be saved

Press twice then press will appear

With this procedure a TOTAL reset will be actived, the pump return to the default settings and all the calibration parameters will be lost.

Press twice then press will appear

With STANBD-BY procedure, the pump is put on stand by

Hold down at until a same time appears

In order to exit this mode, hold down keys “+ / -” at the same time.

ALARM

pH

min

0.00

ALARMOVER DELAY

pH

h:m

02:00

ENTMENUSETPOINT

RESET

RESET

RESET

Page 28: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

28

DOSITEC MF

MULTI-FUNCTION DOSING PUMP

Dosing pump controlled by a microprocessor that allows a manual flow regulation, which is proportional to an incoming pulse rate, 4-20 mA analogical external signal, or with timer.

1 3 4 2

67

8

9

1 Decreasing value button2 Increasing value button3 Previous program button4 Next program button5 START / STOP button6 Display7 Power LED 8 Injection sign LED9 Alarm sign LED

ACCESORIES

- 1 flexible transparent PVC suction hose of 2m (6.56 feet)- 1 semi rigid white PE injection hose of 2m (6.56 feet)- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose

5 MF

STARTSTOP

15:02120 P/MMAN.

29

ALARM LEVEL When the level sensor is connected to the dosing pump (D connector) and detects a lack of additive, stops the injection. This control level have a 5 minutes delay.

PROGRAMMINGFirst screens

Press START/STOP to confirm the value. It will start running automatically according to the selected frequency.

MENU SELECT

MANUALMENU SELECT

PULSE / MIN.

MENU SELECT

PULSE / HR.

MENU SELECT

PULSE / DAY

Select the pulse / minute value through

PULSE / MINUTE

120

Select the pulse / hour value through PULSE / HOUR

120

Select the pulse / day value through

PULSE / DAY

48

First step: define the dosing control mode - MANUAL / 1xN / 1xN(M) / 1-N / mA / PPM

MANUAL MODEThis method allows to operate the pump automatically, running a constant dosing. The pulse rate can be predetermine upon 3 different scales.

MAN. 120P/M

00:00

MENU SELECT

MANUALMENU SELECT

1xN

MENU SELECT

1xN(M)

MENU SELECT

mA

MENU SELECT

PPM

MENU SELECT

1-N

MENU SELECT

ALARM

MENU SELECT

REMOTE

MENU SELECT

BUZZERMENU SELECT

CLOCK

MENU SELECT

TIMER

MENU SELECT

LENGUAGE

Page 29: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

28

DOSITEC MF

MULTI-FUNCTION DOSING PUMP

Dosing pump controlled by a microprocessor that allows a manual flow regulation, which is proportional to an incoming pulse rate, 4-20 mA analogical external signal, or with timer.

1 3 4 2

67

8

9

1 Decreasing value button2 Increasing value button3 Previous program button4 Next program button5 START / STOP button6 Display7 Power LED 8 Injection sign LED9 Alarm sign LED

ACCESORIES

- 1 flexible transparent PVC suction hose of 2m (6.56 feet)- 1 semi rigid white PE injection hose of 2m (6.56 feet)- 1 injection valve 3/8”- 1 filter- 1 instructions manual- 1 flexible transparent PVC priming hose

5 MF

STARTSTOP

15:02120 P/MMAN.

29

ALARM LEVEL When the level sensor is connected to the dosing pump (D connector) and detects a lack of additive, stops the injection. This control level have a 5 minutes delay.

PROGRAMMINGFirst screens

Press START/STOP to confirm the value. It will start running automatically according to the selected frequency.

MENU SELECT

MANUALMENU SELECT

PULSE / MIN.

MENU SELECT

PULSE / HR.

MENU SELECT

PULSE / DAY

Select the pulse / minute value through

PULSE / MINUTE

120

Select the pulse / hour value through PULSE / HOUR

120

Select the pulse / day value through

PULSE / DAY

48

First step: define the dosing control mode - MANUAL / 1xN / 1xN(M) / 1-N / mA / PPM

MANUAL MODEThis method allows to operate the pump automatically, running a constant dosing. The pulse rate can be predetermine upon 3 different scales.

MAN. 120P/M

00:00

MENU SELECT

MANUALMENU SELECT

1xN

MENU SELECT

1xN(M)

MENU SELECT

mA

MENU SELECT

PPM

MENU SELECT

1-N

MENU SELECT

ALARM

MENU SELECT

REMOTE

MENU SELECT

BUZZERMENU SELECT

CLOCK

MENU SELECT

TIMER

MENU SELECT

LENGUAGE

Page 30: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

30

PROPORTIONAL MODEThis operation mode allows running a proportional dosing between the pulses emitted by the water meter, and the pump injections. (Socket B pin 3-4, see page 9)

1XN Function For every pulse received the pump will carry out a series of "N" injections, previously set by the operator, whom can also fix the frequency of the injection.

Example: - Pump set on 1XN function - Value set on: "20"- When the meter or any other element, shut off the contact, the pump starts dosing 20 injections. If there is a new shut off during this process, the pump will not take it in consideration until finishing the 20 injections, then it will restart this process again.

1XN (M) function This function its equivalent to the 1XN function, however in this function all the pulses received are saved at the microprocessor's memory.

Example: When the pump receives the first pulse or contact returns a series of "N" injections at the maximum frequency, for instance: 120 injections / minute.

When the pump receives the second pulse or contact starts computing the time “T” without exceeding the maximum frequency. When the remaining injections are bigger than 4XN an alarm (AL3) will go on. In that case, the pump will keep running however, the remaining injections will get lost.

MENU SELECT

1xN(M)

MENU1xN(M)

10

1xN(M) n=10

12:00

Through select the number of injections and press START /STOP to confirm

1x N n= 10

12:00

MENU SELECT

1xN

MENU 1xN

10

Through select the number of injections and press START /STOP to confirm

1:N functionFor each “N” pulses received the pump does one injection. The value of “N” can be set for the operator.

Example: - Pump set on 1:N function - Value set on "20”- When the meter shut off the contact 20 times, the pump does one injection.

1- N n= 10

12:00

MENU SELECT

1-N

MENU 1-N

10

mA (4-20mA) MODE

This operation mode allows the flow adjustment through a 4-20 mA analogical external signal. It allows setting the maximum and minimum injection speed, according to the 4-20 mA analogical signal. (Socket B pin 1-2, see page 9)

MENU SELECT

mA

SET mA (1)

4.0

SET mA (2)

20.0

PULSE / MIN (1)

0

PULSE / MIN (2)

120

BELLOW mA (1)

CONTINUE

BELLOW mA (1)

STOP

31

Through select the number of injections and press START /STOP to confirm

Through select the current value to indicate the minimum flow desired, and then confirm with

Through select STOP or CONTINUE the injection when the current is bellow the set one (SET mA), then confirm with

Through select the flow (injections/minute) corresponding to the maximum flow desired. Confirm with

Through select the current value to indicate the maximum flow desired, and then confirm with

Through select the flow (injections/minute) corresponding to the minimum current point. Confirm with

Page 31: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

30

PROPORTIONAL MODEThis operation mode allows running a proportional dosing between the pulses emitted by the water meter, and the pump injections. (Socket B pin 3-4, see page 9)

1XN Function For every pulse received the pump will carry out a series of "N" injections, previously set by the operator, whom can also fix the frequency of the injection.

Example: - Pump set on 1XN function - Value set on: "20"- When the meter or any other element, shut off the contact, the pump starts dosing 20 injections. If there is a new shut off during this process, the pump will not take it in consideration until finishing the 20 injections, then it will restart this process again.

1XN (M) function This function its equivalent to the 1XN function, however in this function all the pulses received are saved at the microprocessor's memory.

Example: When the pump receives the first pulse or contact returns a series of "N" injections at the maximum frequency, for instance: 120 injections / minute.

When the pump receives the second pulse or contact starts computing the time “T” without exceeding the maximum frequency. When the remaining injections are bigger than 4XN an alarm (AL3) will go on. In that case, the pump will keep running however, the remaining injections will get lost.

MENU SELECT

1xN(M)

MENU1xN(M)

10

1xN(M) n=10

12:00

Through select the number of injections and press START /STOP to confirm

1x N n= 10

12:00

MENU SELECT

1xN

MENU 1xN

10

Through select the number of injections and press START /STOP to confirm

1:N functionFor each “N” pulses received the pump does one injection. The value of “N” can be set for the operator.

Example: - Pump set on 1:N function - Value set on "20”- When the meter shut off the contact 20 times, the pump does one injection.

1- N n= 10

12:00

MENU SELECT

1-N

MENU 1-N

10

mA (4-20mA) MODE

This operation mode allows the flow adjustment through a 4-20 mA analogical external signal. It allows setting the maximum and minimum injection speed, according to the 4-20 mA analogical signal. (Socket B pin 1-2, see page 9)

MENU SELECT

mA

SET mA (1)

4.0

SET mA (2)

20.0

PULSE / MIN (1)

0

PULSE / MIN (2)

120

BELLOW mA (1)

CONTINUE

BELLOW mA (1)

STOP

31

Through select the number of injections and press START /STOP to confirm

Through select the current value to indicate the minimum flow desired, and then confirm with

Through select STOP or CONTINUE the injection when the current is bellow the set one (SET mA), then confirm with

Through select the flow (injections/minute) corresponding to the maximum flow desired. Confirm with

Through select the current value to indicate the maximum flow desired, and then confirm with

Through select the flow (injections/minute) corresponding to the minimum current point. Confirm with

Page 32: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

32

OVER mA (2)

CONTINUE

OVER mA (2)

STOP

When pressing START/STO the pump will start running according to the configuration set.

mA :00.0

12:00

PPM MODEThis operation mode allows dosing in Parts Per Million. page 9)

(Socket B pin 3-4, see

MENU SELECT

PPM

L/P W.METER

0.10

Through select the litter's value per each pulse from the flow meter (select it according to the meter) and confirm with

cc/ INJECTION

0,01

SOLUTION %

100

SET PPM

1.0

When pressing START/STO the pump will start running according to the configuration set.

PPM = 1.0

12:00

Through select STOP or CONTINUE the injection when the current is below the set one -SET mA (1). Confirm with

Through select the value in p.p.m (parts per million) that is required, (in a rank from 0.01 - 2000 p.p.m) and confirm with

Through select the concentration value (%) of the aditive that the pump needs to inject and confirm with

Through select the injection volumen for each cicle of the pump (see page 4) and confirm with

33

TELECONTROL (REMOTE)The pump can be activated and deactivated through an opening and closing contact located a 100 meters (maximum distance). There are two different operation modes: NORMAL or REVERSED

MENU SELECT

REMOTEMENU REMOTE

NORMAL

MENU REMOTE

REVERSED

ALARMS The pumps provided with flow sensor (which is optional) have a system that in case the pump stops injecting,according to the parameters set, due to any mechanical damage, a alarm goes on and stops the injections. (Socket C pin 1-2, see page 9)

MENU SELECT

ALARMREF. PULSES

0

MAX DIFF.

0

Note: the wires must be conected at the same connectors of the level probe (Socket C pin 3-4, see page 9)

NORMAL mode: Contact opened = pump activated Contact closed = pump in stand-by Through select the functionConfirm with

Through select the pulse rage value of reference and confirm with

Through select the maximum difference of pulses related to the reference ones, and confirm with

REVERSED mode: Contact opened = pump in stand-byContact closed = pump activatedThrough select the functionConfirm with

Page 33: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

32

OVER mA (2)

CONTINUE

OVER mA (2)

STOP

When pressing START/STO the pump will start running according to the configuration set.

mA :00.0

12:00

PPM MODEThis operation mode allows dosing in Parts Per Million. page 9)

(Socket B pin 3-4, see

MENU SELECT

PPM

L/P W.METER

0.10

Through select the litter's value per each pulse from the flow meter (select it according to the meter) and confirm with

cc/ INJECTION

0,01

SOLUTION %

100

SET PPM

1.0

When pressing START/STO the pump will start running according to the configuration set.

PPM = 1.0

12:00

Through select STOP or CONTINUE the injection when the current is below the set one -SET mA (1). Confirm with

Through select the value in p.p.m (parts per million) that is required, (in a rank from 0.01 - 2000 p.p.m) and confirm with

Through select the concentration value (%) of the aditive that the pump needs to inject and confirm with

Through select the injection volumen for each cicle of the pump (see page 4) and confirm with

33

TELECONTROL (REMOTE)The pump can be activated and deactivated through an opening and closing contact located a 100 meters (maximum distance). There are two different operation modes: NORMAL or REVERSED

MENU SELECT

REMOTEMENU REMOTE

NORMAL

MENU REMOTE

REVERSED

ALARMS The pumps provided with flow sensor (which is optional) have a system that in case the pump stops injecting,according to the parameters set, due to any mechanical damage, a alarm goes on and stops the injections. (Socket C pin 1-2, see page 9)

MENU SELECT

ALARMREF. PULSES

0

MAX DIFF.

0

Note: the wires must be conected at the same connectors of the level probe (Socket C pin 3-4, see page 9)

NORMAL mode: Contact opened = pump activated Contact closed = pump in stand-by Through select the functionConfirm with

Through select the pulse rage value of reference and confirm with

Through select the maximum difference of pulses related to the reference ones, and confirm with

REVERSED mode: Contact opened = pump in stand-byContact closed = pump activatedThrough select the functionConfirm with

Page 34: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

34

CLOCKThe pump features a clock with time. Some applications may request the activation or deactivation through this clock.

MENU SELECT

CLOCK

CLOCK SET

2007 JAN “01"

BUZZERThe pump features an acoustic alarm to warn us of any incidence.

MENU SELECT

BUZZERMENU BUZZER

ENABLED

MENU BUZZER

DISABLED

The function ENABLED indicates alarm on Through select functionConfirm with

CLOCK SET

“12:00" - MONThrough select the timeConfirm with

CLOCK SET

“2007" JAN 01

CLOCK SET

12:00 - “MON”

CLOCK SET

2007 “JAN” 01

The function ENABLED indicates alarm on Through select functionConfirm with

Through select the day of the weekConfirm with

Through select the year Confirm with

Through select the monthConfirm with

Through select the day Confirm with

TIMER

The timer menu carries out up to 8 different cycles of activation and deactivation in one day.

MENU SELECT

TIMERMENU TIMER

TIMER OFF

Function TIMER OFF deactivates the timer. Through select the function. Confirm with

SUNDAY SET1

ON 1:00

SUNDAY SET1

OFF 1:20

Repeat this operation according to the number of cycles (maximum 8) requested in one day.

MENU TIMER

WEEK SETS

MENU TIMER

DAYLY SETS

SET1

OFF 1:20

SET1

ON 1:00

Repeat this operation according to the number of cycles (maximum 8) requested in one day.

35

Function SET 1 OFF sets the timing to deactivate the pumpThrough select the function. Confirm with

Function SET 1 ON sets the timing to activate the pumpThrough select the function. Confirm with

Function DALY SETS set up to 8 different cycles of start and stop Through select the function. Confirm with

Function SUNDAY SET 1 OFF set the timing to deactivate the pump on Saturdays. Through select the function. Confirm with

Function WEEK SETS set up to 8 different cycles of start and stopThrough select the function. Confirm with

Function SUNDAY SET 1 ON sets the timing to activate the pump on Saturdays. Through select the function. Confirm with

Page 35: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

34

CLOCKThe pump features a clock with time. Some applications may request the activation or deactivation through this clock.

MENU SELECT

CLOCK

CLOCK SET

2007 JAN “01"

BUZZERThe pump features an acoustic alarm to warn us of any incidence.

MENU SELECT

BUZZERMENU BUZZER

ENABLED

MENU BUZZER

DISABLED

The function ENABLED indicates alarm on Through select functionConfirm with

CLOCK SET

“12:00" - MONThrough select the timeConfirm with

CLOCK SET

“2007" JAN 01

CLOCK SET

12:00 - “MON”

CLOCK SET

2007 “JAN” 01

The function ENABLED indicates alarm on Through select functionConfirm with

Through select the day of the weekConfirm with

Through select the year Confirm with

Through select the monthConfirm with

Through select the day Confirm with

TIMER

The timer menu carries out up to 8 different cycles of activation and deactivation in one day.

MENU SELECT

TIMERMENU TIMER

TIMER OFF

Function TIMER OFF deactivates the timer. Through select the function. Confirm with

SUNDAY SET1

ON 1:00

SUNDAY SET1

OFF 1:20

Repeat this operation according to the number of cycles (maximum 8) requested in one day.

MENU TIMER

WEEK SETS

MENU TIMER

DAYLY SETS

SET1

OFF 1:20

SET1

ON 1:00

Repeat this operation according to the number of cycles (maximum 8) requested in one day.

35

Function SET 1 OFF sets the timing to deactivate the pumpThrough select the function. Confirm with

Function SET 1 ON sets the timing to activate the pumpThrough select the function. Confirm with

Function DALY SETS set up to 8 different cycles of start and stop Through select the function. Confirm with

Function SUNDAY SET 1 OFF set the timing to deactivate the pump on Saturdays. Through select the function. Confirm with

Function WEEK SETS set up to 8 different cycles of start and stopThrough select the function. Confirm with

Function SUNDAY SET 1 ON sets the timing to activate the pump on Saturdays. Through select the function. Confirm with

Page 36: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

LANGUAGE

The language menu allows the selection between two languages.

MENU SELECT

LANGUAGESET LANGUAGE

ENGLISH

English menuThrough select language Confirm with

MENU LINGUA

ITALIANO

Italian menuThrough select language Confirm with

37

7.- MAINTENANCE

Before any maintenance operation we will check:

That the pump is stopped and disconnected from the electric supply.

There is no pressure neither inside the head nor in the impulsion pipe. It is advisable to empty the head before opening it.

The staff in charge of the maintenance will use the adequate protection means in order to manipulate the dosed liquid.

Periodically check the chemical tank level so as to avoid the pump operates without liquid. This would not damage the pump, but may damage the process plant due to lack of chemical. DOSITEC series dosing pumps are all supplied with level control setting. The level switch is not included therefore to be ordered separately.Level control stops pump operation once the level into the chemical is lower then the level switch,activating a L.E.D. on the pump .

Check the pump operating condition at least every 6 months, pump head position,screws, bolts and seals; check more frequently where aggressive chemicals are pumped, especially: - pulse and power L.E.D.; - the additive concentration in the process plant; a reduction of this concentration could be caused by the wearing of the valves, in which case they need to be replaced or by the clogging of the filter which then has to be cleaned as in point 3 here below.

36

Page 37: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

LANGUAGE

The language menu allows the selection between two languages.

MENU SELECT

LANGUAGESET LANGUAGE

ENGLISH

English menuThrough select language Confirm with

MENU LINGUA

ITALIANO

Italian menuThrough select language Confirm with

37

7.- MAINTENANCE

Before any maintenance operation we will check:

That the pump is stopped and disconnected from the electric supply.

There is no pressure neither inside the head nor in the impulsion pipe. It is advisable to empty the head before opening it.

The staff in charge of the maintenance will use the adequate protection means in order to manipulate the dosed liquid.

Periodically check the chemical tank level so as to avoid the pump operates without liquid. This would not damage the pump, but may damage the process plant due to lack of chemical. DOSITEC series dosing pumps are all supplied with level control setting. The level switch is not included therefore to be ordered separately.Level control stops pump operation once the level into the chemical is lower then the level switch,activating a L.E.D. on the pump .

Check the pump operating condition at least every 6 months, pump head position,screws, bolts and seals; check more frequently where aggressive chemicals are pumped, especially: - pulse and power L.E.D.; - the additive concentration in the process plant; a reduction of this concentration could be caused by the wearing of the valves, in which case they need to be replaced or by the clogging of the filter which then has to be cleaned as in point 3 here below.

36

Page 38: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

38

TROUBLE SHOOTING

MECHANICAL FAULTS

As the system is quite robust there are no apparent mechanical problems. Occasionally there might be a loss of liquid from the nipple because the tube nut has loosened, or more simply the discharge tubing-has broken.Very rarely there may be losses caused by the breakage of the membrane, or by the membrane seals in which case they have to be replaced by disassembling the four screws of the pump head, when re-mounting the pump head ensure that the screws are replaced properly, along with “O” ring.After repair, the metering pump will need to be cleaned of additive residues which can damage the pump casing.

PROBLEM

tThe pump gives pulses but doesn’t inject

The pump doesn’t give any pulse and LED are off

The pump gives only one pulse

The pump doesn’t give any pulse and green LED is on and red LED is off

Pump pulses are not constant

CAUSE

Valves not clean

Damaged valves

Filter not clean

Power supply failure

START failure

Power supply failure

SOLUTIÓN

Remove the suction and injection valves, clean them , and assemble them in the same position.

When the parts are swallen, check valve material against a chemical compatibility chart and fit the correct material.

Clean the filter

Chech the power supply. If it still doesn’t work contact with the Technical Service

Press START/STOP.If it still doesn’t work contact with the Technical Service.

Check the input voltageis within +/- 10% rated voltage

Disconnect the pump and contact immediately to the Technical Service

DOSITEC PARTS

39

5920059154 59300

5960559607

5915559311

59310

59213

59158

59209

59309

59308

59212

596105961159612

592035920459205

59210

59211

592065920759208

596135961459615

5920159202

59-050-F

59807-F

59809-F 59810-F

59303 59306

59303

59800-F

59302

59305

59157

59-862-F

59156-F

59805-F 59848

59307

59-863-F

59801-F

59849

Page 39: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

38

TROUBLE SHOOTING

MECHANICAL FAULTS

As the system is quite robust there are no apparent mechanical problems. Occasionally there might be a loss of liquid from the nipple because the tube nut has loosened, or more simply the discharge tubing-has broken.Very rarely there may be losses caused by the breakage of the membrane, or by the membrane seals in which case they have to be replaced by disassembling the four screws of the pump head, when re-mounting the pump head ensure that the screws are replaced properly, along with “O” ring.After repair, the metering pump will need to be cleaned of additive residues which can damage the pump casing.

PROBLEM

tThe pump gives pulses but doesn’t inject

The pump doesn’t give any pulse and LED are off

The pump gives only one pulse

The pump doesn’t give any pulse and green LED is on and red LED is off

Pump pulses are not constant

CAUSE

Valves not clean

Damaged valves

Filter not clean

Power supply failure

START failure

Power supply failure

SOLUTIÓN

Remove the suction and injection valves, clean them , and assemble them in the same position.

When the parts are swallen, check valve material against a chemical compatibility chart and fit the correct material.

Clean the filter

Chech the power supply. If it still doesn’t work contact with the Technical Service

Press START/STOP.If it still doesn’t work contact with the Technical Service.

Check the input voltageis within +/- 10% rated voltage

Disconnect the pump and contact immediately to the Technical Service

DOSITEC PARTS

39

5920059154 59300

5960559607

5915559311

59310

59213

59158

59209

59309

59308

59212

596105961159612

592035920459205

59210

59211

592065920759208

596135961459615

5920159202

59-050-F

59807-F

59809-F 59810-F

59303 59306

59303

59800-F

59302

59305

59157

59-862-F

59156-F

59805-F 59848

59307

59-863-F

59801-F

59849

Page 40: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

LIST OF PARTS

CODE DESCRIPTION UNITS59101 PLATE FOR LEVEL SENSOR STAND 159153 ELECTRIC CABLE 159154 CONNECTOR G4W1F 259155 CONNECTOR G4A5M 259156-F CYLINDER DIAPHAGM PVDF 159157 CYLINDER CAP 459158 DIAPHRAGM FLANGE 159200 PTFE DIAPHAGM 159201 LOWER LEXAN 159202 LOWER LEXAN STROKE REGULATION 159203 LEXAN MP 159204 LEXAN MD 159205 LEXAN Q 159206 LEXAN mA 159207 LEXAN MF 159208 LEXAN PRC 159209 CYLINDER COVER 159210 HYDRAULIC CASE 159211 ELECTRONIC CASE 159212 FLOW ADJUSTMENT KNOB 159213 CASE O-RING 159300 M4X8 INOX SCREW 459302 M4 6593 WASHER 459303 2087 O-RING FOR DRAIN VALVE 259304 LIP VALVE O'RING 159305 M4X35 DIN 912 INOX SCREW 459306 2819 O-RING FOR DRAIN VALVE 159307 2816 O-RING VITON 159308 SCREW 2.9X9.5 459309 SCREW 4X16 INOX 659310 SCREW 2.9X13 259311 CABLE CLAMP 159605 D 80 2-10 ELECTROMAGNET 159607 D 90 8-10 ELECTROMAGNET 159610 MP ELECTRONICA CARD 159611 MD ELECTRONICA CARD 159612 Q ELECTRONICA CARD 159613 mA ELECTRONICA CARD 159614 MF ELECTRONICA CARD 159615 PRC ELECTRONICA CARD 159800-F DRAIN CONNECTER PVDF 159801-F SEPARATOR OF INJECTION VALVE PVDF 159805-F 3/8" LIP VALVE GUIDE PVDF 159807-F DRAIN CONTROL PVDF 159808 O-RING 159809-F DRAIN SCREW PVDF 159810-F DRAIN ROD PVDF 159811 CYLINDER FOR INYECTION VALVE 159812 BODY OF INYECTION VALVE 159813 FOOT FILTER NET 159814 FOOT FILTER CONE 159-851-P 4x6 FOOT FILTER 1

ASSEMBLY59-080-F CYLINDER DOSITEC ASSEMBLY PVDF/ FPM 159-806 3/8” CHECK VALVE 159-851-P FOOT FILTER 4X6 159-862-F SUCTION CHECK VALVE BALL 4x6 PVDF/FPM 159-863-F DISCHARGE CHECK VALVE BALL4X6 PVDF / FPM 1

BALL VALVE 4x6 PVDF / FPM

FOOT FILTER 4X6

40

5981759802

5981359812

59824

59811

59-806 59-851-P

CHECK VALVE 4X6

Suction 59-862-F Discharge 59-863-F

1

2

3

4

6

5

13

12

10

11

9

8

9

7

10

8

7

1

2

3

4

6

5

13

12

10

11

7

8

7

9

10

8

9

Page 41: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

LIST OF PARTS

CODE DESCRIPTION UNITS59101 PLATE FOR LEVEL SENSOR STAND 159153 ELECTRIC CABLE 159154 CONNECTOR G4W1F 259155 CONNECTOR G4A5M 259156-F CYLINDER DIAPHAGM PVDF 159157 CYLINDER CAP 459158 DIAPHRAGM FLANGE 159200 PTFE DIAPHAGM 159201 LOWER LEXAN 159202 LOWER LEXAN STROKE REGULATION 159203 LEXAN MP 159204 LEXAN MD 159205 LEXAN Q 159206 LEXAN mA 159207 LEXAN MF 159208 LEXAN PRC 159209 CYLINDER COVER 159210 HYDRAULIC CASE 159211 ELECTRONIC CASE 159212 FLOW ADJUSTMENT KNOB 159213 CASE O-RING 159300 M4X8 INOX SCREW 459302 M4 6593 WASHER 459303 2087 O-RING FOR DRAIN VALVE 259304 LIP VALVE O'RING 159305 M4X35 DIN 912 INOX SCREW 459306 2819 O-RING FOR DRAIN VALVE 159307 2816 O-RING VITON 159308 SCREW 2.9X9.5 459309 SCREW 4X16 INOX 659310 SCREW 2.9X13 259311 CABLE CLAMP 159605 D 80 2-10 ELECTROMAGNET 159607 D 90 8-10 ELECTROMAGNET 159610 MP ELECTRONICA CARD 159611 MD ELECTRONICA CARD 159612 Q ELECTRONICA CARD 159613 mA ELECTRONICA CARD 159614 MF ELECTRONICA CARD 159615 PRC ELECTRONICA CARD 159800-F DRAIN CONNECTER PVDF 159801-F SEPARATOR OF INJECTION VALVE PVDF 159805-F 3/8" LIP VALVE GUIDE PVDF 159807-F DRAIN CONTROL PVDF 159808 O-RING 159809-F DRAIN SCREW PVDF 159810-F DRAIN ROD PVDF 159811 CYLINDER FOR INYECTION VALVE 159812 BODY OF INYECTION VALVE 159813 FOOT FILTER NET 159814 FOOT FILTER CONE 159-851-P 4x6 FOOT FILTER 1

ASSEMBLY59-080-F CYLINDER DOSITEC ASSEMBLY PVDF/ FPM 159-806 3/8” CHECK VALVE 159-851-P FOOT FILTER 4X6 159-862-F SUCTION CHECK VALVE BALL 4x6 PVDF/FPM 159-863-F DISCHARGE CHECK VALVE BALL4X6 PVDF / FPM 1

BALL VALVE 4x6 PVDF / FPM

FOOT FILTER 4X6

40

5981759802

5981359812

59824

59811

59-806 59-851-P

CHECK VALVE 4X6

Suction 59-862-F Discharge 59-863-F

1

2

3

4

6

5

13

12

10

11

9

8

9

7

10

8

7

1

2

3

4

6

5

13

12

10

11

7

8

7

9

10

8

9

Page 42: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

42

I.T.C. S.L. warrants the product specified in this document for a period of 2 years fromt he purchase date except for the wearing parts such as valves, seals, nipples, hoses and filter. This warranty obligation is limited to the free replacement of the damaged parts due to any material or manufacture defect. This warranty does not include periodic maintenance and damage resulting from misuse.

The equipment must be sent to I.T.C. S.L. Service Center with prepaid transport charges, and will be sent back with transport charges for customer’s account.

The warranty document with sales date and shop stamp or an invoice copy must be sent with the equipment.W

AR

RA

NT

Y

Date of sale and shop stamp

DATE:SERIAL #

MODEL

EC CONFORMITY DECLARATION

I.T.C S.L..Mar Adriàtic, 1Polígono Torre del Rector08130 Santa Perpètua de Mogoda

Declares that all models DOSITEC products, identified by a serial number and year of manufacture, strictly fulfill low voltages directives 73/23/CE and electromagnetic compatibility directives 89/336/CE, as long as installation, use and maintenance are carried out following the prevailing regulation and following the instructions contained in the handbook.

Antón PlanasManager

Page 43: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

42

I.T.C. S.L. warrants the product specified in this document for a period of 2 years fromt he purchase date except for the wearing parts such as valves, seals, nipples, hoses and filter. This warranty obligation is limited to the free replacement of the damaged parts due to any material or manufacture defect. This warranty does not include periodic maintenance and damage resulting from misuse.

The equipment must be sent to I.T.C. S.L. Service Center with prepaid transport charges, and will be sent back with transport charges for customer’s account.

The warranty document with sales date and shop stamp or an invoice copy must be sent with the equipment.W

AR

RA

NT

Y

Date of sale and shop stamp

DATE:SERIAL #

MODEL

EC CONFORMITY DECLARATION

I.T.C S.L..Mar Adriàtic, 1Polígono Torre del Rector08130 Santa Perpètua de Mogoda

Declares that all models DOSITEC products, identified by a serial number and year of manufacture, strictly fulfill low voltages directives 73/23/CE and electromagnetic compatibility directives 89/336/CE, as long as installation, use and maintenance are carried out following the prevailing regulation and following the instructions contained in the handbook.

Antón PlanasManager

Page 44: DOSITEC€¦ · Hydraulic connection 7 Electric connection 9 6.- START UP 10 DOSITEC - MP 12 DOSITEC - MD 13 DOSITEC - mA 14 DOSITEC - Q 17 DOSITEC - PRC 20 DOSITEC - MF 28 7.- MAINTENANCE

C/ Del Mar Adriàtic nº 1 Pol. Ind. Torre del RectorP.O. Box 6008130 STA. PERPETUA DE MOGODABARCELONA - SPAIN

Tel. 935 44 30 40 Fax 935 544 31 61e-mail: [email protected] www.itc.es

Ed: 01/10/2010-AN