Transcript
Page 1: 3. 5. 7. ABB Solar inverters Quick installation guide ......TP14 TP2 2 TP24 TP23 TP13 TP3 TP12 TP6 TP4 J3 TP7 TP25 TP2 J1 TP21 TP18 TP17 TP20 J2 2 8 7 1 7 23 24 A C 1 1 2 B A C 8

1.

2.

3.

4.

5.

Asse

mbl

y In

stru

ctio

ns

Inpu

t/out

put c

onne

ctio

ns

Mai

n co

mpo

nent

sLi

st o

f com

pone

nts

supp

lied

Ope

ratin

g di

agra

m

The main components of the ETHERNET expansion board are shown in the figure below and described in the following table:

Main componentsA Connection terminalsB Ethernet port

C Mechanical mounting bracket

The Ethernet cable for the connection of the “ETHERNET expansion board” must be fed through the inverter service cable gland shown in the figure below. This cable gland is equipped with a special gasket that fits the cable with the preinstalled connector:

Once the cable is fed through the cable gland, proceed with the installation of the supplied toroid:

Finally connect the cable to the Ethernet port on the accessory board.

1 2 3 4

The “ETHERNET expansion board” allows to connect the inverter to a local LAN network via an Ethernet connection.

The “ETHERNET expansion board” features an integrated web server that enables to establish a direct connection to a PC, allowing for board configu-ration and local monitoring of the inverter.

Ethernet

Ethernetweb userinterface

TRIO

POWER ALARM GFI ESC UP DOWN ENTER

When the inverter is connected to the LAN network with access to the In-ternet, the Ethernet board allows to transfer data to the Plant Viewer/Aurora Vision® portal for remote monitoring purposes (over an Internet browser)

Router

Web portal“Aurora Vision Plant Viewer”

EthernetEthernet

Ethernet

TRIO

POWER ALARM GFI ESC UP DOWN ENTER

TRIO

POWER ALARM GFI ESC UP DOWN ENTER

TRIO

POWER ALARM GFI ESC UP DOWN ENTER

Ethernetweb userinterface

Ethe

rnet

Wi-F

i

or Internet

The inside of the inverter may only be accessed after the equipment has been disconnected from the grid and from the photovoltaic generator.

• Turn off the inverter by physically disconnecting the AC and DC voltages, as well as any voltage connected to the multi-function relay.

• Open the inverter front cover.

• Install the ETHERNET board by fitting the connection terminals A in the special receptacle on the inverter control and communication board (SLOT 1).During this step, check that all the terminals are correctly aligned. Any terminal misalignment may result in damage to the ETHERNET board and/or to the inverter.

• Tighten the locking screw to fix the Ethernet board to the inverter. The screw secures the mounting bracket C to the anchor point on the inverter.

1

R S T N G

R28 U2 U1R29R30R31 D3

D2

U4

R2

R1C1

R32R33R34

R22R23C12

U5

R5R4R3Q1

D4R24C11 U6

R7R6C21

R35 L2

L1

U7

R8

R36R37

R27R26R25C13

U8

R10

R9

D6R39

L3C14

LED1

R12R11

R13

C43

C44R58

C31

R52

C29 C26 C23

D7 R67

R68

R21 LED2

LED3R16

C5 C2

R59

C45

U11

D5 C24

C27

XTAL2

C15 C9

C7U3

R60 C36C37 L4 R38

LAB1

R56

R53

R48

R51

R54

C6 C3

C30

C25XTAL3

R47 R44

R45

C8R20R18

R19R15

R17C4

C34C38

C10

U10

C39

R49

R46C28

C35 U12

U9

D1R14C19

C40R57

C32

C48 R61

R55C41C47 C20

R62R63 R65R64 R66C33

L5

C22

R40 R41

LED4

LED5

TP5

TP14TP22TP24

TP23

TP13 TP3

TP12

TP6

TP4

J3

TP7

TP25TP2

J1TP21TP18TP17

TP20

J2

2

8

7

1

7

23 24

AC

1

1 2

Once the installation is completed, the Ethernet cable can be connected to the dedicated port.

R28 U2 U1R29R30R31 D3

D2

U4

R2

R1C1

R32R33R34

R22R23C12

U5

R5R4R3Q1

D4R24C11 U6

R7R6C21

R35 L2

L1

U7

R8

R36R37

R27R26R25C13

U8

R10

R9

D6R39

L3C14

LED1

R12R11

R13

C43

C44R58

C31

R52

C29 C26 C23

D7 R67

R68

R21 LED2

LED3R16

C5 C2

R59

C45

U11

D5 C24

C27

XTAL2

C15 C9

C7U3

R60 C36C37 L4 R38

LAB1

R56

R53

R48

R51

R54

C6 C3

C30

C25XTAL3

R47 R44

R45

C8R20R18

R19R15

R17C4

C34C38

C10

U10

C39

R49

R46C28

C35 U12

U9

D1R14C19

C40R57

C32

C48 R61

R55C41C47 C20

R62R63 R65R64 R66C33

L5

C22

R40 R41

LED4

LED5

TP5

TP14TP22TP24

TP23

TP13 TP3

TP12

TP6

TP4

J3

TP7

TP25TP2

J1TP21TP18TP17

TP20

J2

2

8

71

7

23 24

AC

1

1 2

The packaging contains all the components required to correctly install and connect the ETHERNET expansion board:Available components Qty

Locking screw 1

+ Toroid + Cable Tie 1 + 1

In addition to what is explained in this guide, the safety and installation information provided in the installation manual must be read and followed.

The technical documentation and the interface and management software for the product are available at the website.

XXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXX

ABB solar inverters

Quick installation guide 1

R28 U2 U1R29R30R31 D3

D2

U4

R2

R1C1

R32R33R34

R22R23C12

U5

R5R4R3Q1

D4R24C11 U6

R7R6C21

R35 L2

L1

U7

R8

R36R37

R27R26R25C13

U8

R10

R9

D6R39

L3C14

LED1

R12R11

R13

C43

C44R58

C31

R52

C29 C26 C23

D7 R67

R68

R21 LED2

LED3R16

C5 C2

R59

C45

U11

D5 C24

C27

XTAL2

C15 C9

C7U3

R60 C36C37 L4 R38

LAB1

R56

R53

R48

R51

R54

C6 C3

C30

C25XTAL3

R47 R44

R45

C8R20R18

R19R15

R17C4

C34C38

C10

U10

C39

R49

R46C28

C35 U12

U9

D1R14C19

C40R57

C32

C48 R61

R55C41C47 C20

R62R63 R65R64 R66C33

L5

C22

R40 R41

LED4

LED5

TP5

TP14TP22TP24

TP23

TP13 TP3

TP12

TP6

TP4

J3

TP7

TP25TP2

J1TP21TP18TP17

TP20

J2

2

8

71

7

23 24

AC

1

1 2

B

A

C

8.

7.

Char

acte

ristic

s an

d te

chni

cal d

ata

Inte

grat

ed w

ebse

rver

CommunicationCommunication protocol Ethernet/IP, Modbus TCP

Communication services Manual IP address assignment, Bootp, DHCP Ethernet

Webserver Integrated webserverConnectivityCabled ports RJ45 connector for Ethernet cable

Ethernet cable Cat. 5 UTPFeatures

Led 1 ModBus TCP LED, 1 Ethernet LED, 1 Net-work Status LED

Baud rate 10/100 Mbps

6.

On-

disp

lay

confi

gura

tion

Upon starting the inverter for the first time after the ETHERNET board has been installed, a new “ETHERNET Board” section is added to the SET-TINGS menu, with the following tree:

• “DHCP” section Enables/disables dynamic address assignment of the Ethernet board.If DHCP is disabled, the Ethernet board IP address must be manually set (“IP Address” section).

• “Address IP” section Sets the Ethernet board IP address.

• “Gateway” section Sets the IP address of the gateway receiving the data from the monitored system.

• “Netmask” sectionSets the subnet mask for the Internet network.

• “Primary DNS” sectionSets the primary DNS for the Internet network.

• “Secondary DNS” section Sets the secondary DNS for the Inter-net network.

• “Portal IP add.” sectionSets the Aurora Vision® portal IP ad-dress.

• “AV Method” sectionEnables/disables data transmission to the Aurora Vision®/Plant Viewer portal.

• “Data to portal” sectionEnables/disables data transmission to the portal

• “Send events” sectionEnables/disables sending events (error codes) to the portal.

• “Check Updates” sectionEnables/disables checking for “ETHERNET expansion board” firmwa-re updates.

• “Data send time” sectionSets the time for the data transmission to the portal (not available on the current product version). The default value is 900 seconds.

ETHERNET Board

ADDRESS IP

GATEWAY

NETMASK

PRIMARY DNS

SECONDARY DNS

PORTAL IP ADD.

GATEWAY xxx.xxx.xxx.xxx

NETMASK xxx.xxx.xxx.xxx

PRIMARY DNS xxx.xxx.xxx.xxx

ADDRESS IP xxx.xxx.xxx.xxx

SECONDARY DNS xxx.xxx.xxx.xxx

PORTAL IP ADD. xxx.xxx.xxx.xxx

DHCP

DHCP Disable/En.

AV Method

AV Method Disable/En.

DATA TO PORTAL

DATA TO PORTAL Disable/En.

SEND EVENTS

EV. TO PORTAL Disable/En

CHECK UPDATES

Data to portal Disable/En

DATA SEND TIME

Data to portal 900 Sec

DHCP Disable/En.

Data to portal 900 Sec

An internal webserver integrated in the Ethernet board is available for con-figuration and monitoring.

The HOME screen shows general information about the network (IP ad-dress, MAC address, date and time), the generated energy, the CO2 emis-sions and the inverter (output power, inverter model and inverter state).

• VIEW menuDisplays specific information about the inverter (inverter info) and the system (system info).

•CONFIG menu Enter the default username and password (admin/admin) to edit system and network parameters, date and time, and password.

• UPGRADE menuUpdates the Ethernet board firmware.

• REGISTRATION menuUsed to register on the Aurora Vision® portal.

The device must be used in the manner described in the manual. If this is not the case the safety devices gua-ranteed by the inverter might be ineffective.

ABB Solar invertersQuick installation guideETHERNET expansion board

EN

Contact uswww.abb.com/solarinverters

ETHERNET expansion board-Quick Installation Guide EN-RevBEFFECTIVE 2014-04-24

© Copyright 2014 ABB. All Rights Reserved.Specifications subject to change without notice.

Top Related