HDC Series MCCB
2006/2007
En-2006-1
COVEROFH STMF.indd 3 1/20/04 10:07:12 AM
-
7/28/2019 305 MCCB Hager Range
2/34
the success is in the system
Welcome to the Hager HDC series moulded case circuit breaker 2006/2007
catalogue. You will get to know more detailed information about the Hager
distribution system.
Hager provides a complete range of distribution system products for you. We have
labeled products with corresponding color coded pictogram for you to know more
about Hager product.
If you have any suggestion or request for help, please contact your nearest Hager
office.
Distribution boards
Widely used as the distribution board in residential building
and commercial purpose that includes plastic type and
metal type. Hager provides complete range of distribution
enclosures for commercial and industrial distribution system.
Modular protection devices & main switchgear
Modular protection devices include: miniature circuit breaker,
residual current circuit breaker, fuse carrier, contactor, time
switch, surge protection device, isolating switch, etc. and
related auxiliary equipment and accessory.
Main switchgear product includes: moulded case circuit
breaker, load break switch, etc.
Connection devices
Connection block, connector, bus bar and terminals.
Wiring Accessories
Hager wiring accessories include: system 8000, 9000, 9088,
metallic range, door bell, emergency light, etc.
Intelligent building management system
Hager provides a complete set of devices for intelligent
building management system, which includes: timer,
temperature controller, presence detector, building automation
system based on EIB bus system, remote control system, etc.
Cable management system
Hager provides a complete set of cabling system for cable
management system.
Security systemHager security system includes smoke detector, monitoring
system, entrance guard system, anti-intrusion alarm, etc.
HDCCATAL STMF.indd 1 1/23/04 12:12:31 PM
-
7/28/2019 305 MCCB Hager Range
3/34
Hager is originated from
Germany in 1955 as a
manufacturer of low voltage
distribution system with
European leading technology
that provides a complete solution
suitable for residential, industrial
and commercial application with
reliable connection devices and
modular devices for protection,
control and measurement.
To meet the requirement of
the market as well as service
demanded by our partners and
customers, Hager has designed
a short production cycle and
efficient production process.
By integrating flexibility and
creativity, comprehension of
the international market as well
as advanced development and
research technology, these
factors guarantee Hager as an
excellent international brand.
Today, Hagers more than 20
production bases are located
over the world. Our product
is present in more than 40
countries and meets local
requirement and standard.
Hager has a reliable and well
organised sales team. Our local
sales company and partners
together provide excellent
product and service for all our
customers.
Hager Group
Made by hager is the guarantee
of product quality for the whole
system.
2
HDCCATAL STMF.indd 2 1/23/04 12:12:38 PM
-
7/28/2019 305 MCCB Hager Range
4/34
the success is in the system
3
HDCCATAL STMF.indd 3 1/23/04 12:12:47 PM
-
7/28/2019 305 MCCB Hager Range
5/34
4
Product Range Summary
HDC series
moulded case
circuit breaker
HDC series MCCB
125A frame and
accessory
Page 12
HDC series MCCB
250A frame and
accessory
Page 14
HDC series MCCB
800A frame and
accessory
Page 16
Technical
information
28
Product Description of H D C Serial MCCB
a d
aa
bb b
c
F ramecapacity
Modelframe
Numberofpoles
Rated current( A)
5VCPFCTFCODKGPVVGORGTCVWTG
Ratedi solation voltageU i (V)
Rated limited shortbreakingcapacityIcu(k A)
GB14048.2IEC60947-2EN60947-2 Icu / Ics
400V A C
Externaldimension (mm)
Weight (kg)
S tandard function and characteristic
Releasemethod
Releasetestingbutto n
Break indicatinglamp
Manualsafety device(O FF-Lock)
*Onlyappl icablefor HXA /B /C/D033
Connection
method
Life
Frontboardconnectingl ine
125A 250 A 4 00 A 8 00 A
h 125 t c , h125td,h 125t n h250tc,h 250t d h 400tnh 800tn
3 4 3 4 3 4 3 4
16, 20,25, 32,
40,5 0,63,80,
100,125
125,160,
200,225,250
250
320
400
500
630
800
690V A C
Icu /Ics
18/1425 /19
35 /25
690 V A C 69 0V A C 690 V A C
25/19
35/255 0/35 5 0/35
Icu /Ics Icu/ Ics I cu/Ics
a
b
c
d
aa
bb
155 165 260 273
86 86 103 103
104 10 4 1 30 145
30 35 45 70
1 32 1 26 2 14 2 43
9 0 1 2 0 1 05 1 40 1 4 0 1 7 3 2 1 0 2 79
1 . 4 1 .9 1 . 8 2 . 4 5.3 7 9. 4 1 2 .5
Therm al-m agnetic T h e r ma l - m ag n e t ic Therm al-m agnetic (adjus table)
8000 60 00 3 00 0 2500
1 00 0 0 8 00 0 6000 6000
.!
.!
.!
.!
.! .! .!
.!
.! .! .!
Right
:Appl ic able(purc has eaddi tional ly ) .:Notappl ic able
Therm al-m agnetic (adjus table)
Rearboardconnectingline
Plug-intypeconnectingline
Draw-outtypedevice
Attacheddevicecanbei nstalledadditionally
Internal
accessory
External
accessory
Shunttrip
Undervoltagetrip
AuxiliaryswitchAUX
AlarmswitchALM
Auxiliaryalarmsw itch AUX+A LM
Electric driving operating mechanism
Rotaryhandledevice
Auxiliaryhandle
Interlacingdivisionboard
Extended
Electriclife(timeofoperation)
Mechanicallife(ti meofoperation)
Right
Right
Right
Right
RightRight
Right
Right
Left
Left,right
Left,right
Left,right
LeftLeft
Left
Left
Left,right
Left
Left
HDC series MCCB
Product description
Page 18
33
Characteristic Curve of H D C Serial MCCB
16
20
32
40506080
100
125
208 42
260 52
416 83520 104650 130
819 164975 195
1300 260
1625 325
125
160
200
225
250
1594 281
2040 3602550 450
2869 5 06
3188 563
125Arelease curve 250Arelease curve
400Arelease curve 800A releasecurve(In:500A- 630A)
4
3
2
150
4 03 0
2 0
1 0
8
654
3
2
1
504 0
3 0
2 0
1 08
6543
2
10 .8
0 .60 .5
0 .40 .3
0 .2
0 .1
0.080 . 060 . 050.04
0.03
0.02
0.01
0.008
0.00 60.00 5 08 09 001
521
002052
003004
005006
007008
009
0001
0051
0002
0052
0003
0004
0005
0006
0007
0008
051
DNOCES
ETUNIM
RUOH
50 050 0 050 0
X 5X 1 0
5
63 0 63 0 063 0
Tripcurrent value
Ther e ar e 5phases that canbe adjust ed wi t hin adjust abl er ange of elect r omagnet t r ip
Rated c urrent(A)
h800 t
Actiontime
%ofratedc urrents etvalueinc om paris on
Trip c urrentv alue(A) (x 10)
M in
Max
40004 0 0
Trip c urrentv alue
32003 2 0250 0250
4 0 0
2503 2 0
0.010 . 0 0 8
0.00 60.00 5
0 .10.08
0 . 060 . 05
0.03
0.02
0.04
0 .8
0 .60 .50 .40 .3
0 .2
NOCES
D
1
1 0
2
43
8
56
504 03 0
2 0
1
2
1 0
ETUNIM
4
3
568
4 0
3 0
50
RUOH
1
3
2
4
2 0
0908 0 1
021
551
002
052
003
004
005
006
007
0 0 001
09
008
0 0051
0052
0002
0003
0004
0005
0008
0007
0006
Min
LO HI Ther e ar e5 phases t hat canbe adjusted wi t hin adjustabl e
range of elect r omagnet t rip
Ratedc urrent(A)
h400tn
Max
Actiontime
%ofratedc urrents etv alueinc om paris on
Tripc urrentv alue(A)
16A~32AM ax
40A~125AM ax
20A~32AM in
40A~125AM in
Tripc urrentv alue
Ratedc urrent(A)TripCurrent(A)
Tripc urrentv alue
Ratedc urrent(A)TripCurrent(A)
Act
io nt ime
Act io nt ime
%ofrated c urrents etv aluei n compar is on %ofrated c urren ts etv alue in compar i s on
HDC series MCCB
Characteristic curve
Page 23
35
HDCSerial MCCB Accessory
42
65
65
4.5
200
45
5 3
36
2- 5 .50200
42
65
65
4.50
200
80
8 0 H
61
H
93
9 3
H
Ref.No.HXA031HXB031
HXC031HXD031
H
6565
9595
H
65659595
HXA032HXB032HXC032HXD032
H
65659595
HXA033HXB033HXC033HXD033
OFF positioncaninstalllocktool(applicablefor HX*033)
Optionalaccessory
Standard configured EH1rotary handledevice
HXC031
HXC032
HXC033
Install on distribution boxdoor
Protectionlevel:HX*031/HX*032IP30H X *0 3 3 I P 65
Rotary handle
Ref.No.
Ref.No.
HDC series MCCB
Accessory
Page 25
32
DimensionD escription of HDCSerial MCCB
125Aframe
F r o ntw i n d ow s i z e 3 p o l es
55
28
R1
1 3 2 15
5
90
30
M4X0.7Fix edSc r
N
1 3 2 15
5
120
60
1 0 2
86
104
5 2
28
R2
165
1 26
M4X0.7Fix edSc r
35
105
165
1 26
70
140
86
104
R2
9 2
64
M6X0.7Fix edSc r
260
140
45
131
129
108
106
260
173
135
45
131
129
108
106
N
45
131
697
103
55
47
9 2
64
M8X0.7Fix edSc r
1 4 1
70
210
1 3 2
8 0
70
8 0
40
126
117
70 70
1 4 1
279
1 3 2
8 0
8 0
126
117
7.5
32
103
6
348
14580.5
8
5 7
4 5
4 p ol es L at er al f ac e
250Aframe
F ro nt w in do w s iz e 3 po le s 4 p ol es L at er al f ac e
400AframeF ro nt w in do w s iz e 3 po le s 4 p ol es L at er al f ac e
800AframeF ro nt w in do w s iz e 3 po le s 4 p ol es L at er al f ac e
HDC series MCCB
Dimension
Page 22
29
Model Labeling Method of H D C Serial MCCB
Model labeling method of MCCB
1.Mainproduct number
2.Productcategory&br eakingcapacity
D=16-18kAmouldedcasecircuitbreaker
H=25kAmouldedcaseci rcuitbreaker
N=35-50kAmouldedcasecircuitbreakerX=auxiliarydevice
Y=accessory
3.Frametype
A=125frame
B=250frame
C=400frameD=800frame
4.Ratedcurrent
3poles4poles
1 6 A = 01 6 0 1 7
2 0 A = 02 0 0 2 1
2 5 A = 02 5 0 2 6
3 2 A = 03 2 0 3 3
4 0 A = 04 0 0 4 1
5 0 A = 05 0 0 5 16 3 A = 06 3 0 6 4
8 0 A = 08 0 0 8 1
5.Serial
C=lowprofile
D=intermediateprofile
Note: If accessory is ordered with moulded case circuit breaker together,please fill moulded case circuit breaker numb er and accessorynumber
insteadofprod uctnumberon ordersheet. Ifaccessoryisor deredindividually,then youjustfillaccessor ynumber.Fore xample , y o u o r d e r 1 2 5frame16A,35kA andoperati ngrotaryhan dledevicewithcentr alregulatingcrank structure,andthen youshoul dwriteHNA016D/ HX031-EH1.
ifaccessoryisor derindividually,then itshouldbeHX031-EH1.
SHT(shunttri p)l
Shunttripisused tocontrolgate off
atlongdistancel
Instantaneousworking mechanisml
Optionalaccessoryl
Operationcharacteri stic(seetable 1)
UVT(undervoltagetrip)l
Undervoltagetripis usedtoprovide undervoltage
protectionforci rcuitandelectric devicel
Undervoltagetripcan beusedasshun ttriploperation
Characteristic(seetab le2)
Shunt Trip SHT, Undervoltage Trip UVT
1.Mainproduct number
Shunttri p ( t a b l e 1 )
Undervoltagetrip( table2)
Operatingelectricacce ssory
Operatingpower voltagerange
Ratedcontrolpower voltage
Operatingelectrica ccessory
Operatingvoltage
Guaranteedswitch-on voltage
Guaranteedswitch-off voltage
Shunttrip
(0.7-1.1)xUn
24VAC
(0.35-0.7)xUe
(0.85-1.17)xUe
0.35-Ue
24VDC
1 10 VA C 2 3 0V AC 4 00 VA C
2 3 0 VA C 4 0 0 VA C
H
H
2.Auxiliarydevice
3.Frametype
A=125frame
B=250frameC=400frame
D=800frame
4.Voltageused
Shuntrelease:006=24VDC
001=24VAC
003=110VAC004=230VAC
005=400VAC
Undervoltagerelease:014=230VACbelow
015=400VACbelow
5.Installationlocation
R=installatrightsi de
L-installatleftside
X
3pole s 4 p o l e s
1 0 0 A =1 0 0 1 0 1
1 2 5 A =1 2 5 1 2 61 6 0 A =1 6 0 1 6 1
2 0 0 A =2 0 0 2 0 1
2 2 5 A =2 2 5 2 2 6
2 5 0 A =2 2 5 2 5 1
3 2 0 A =3 2 0 3 2 1
4 0 0 A =4 0 0 4 0 15 0 0 A =5 0 0 5 0 1
6 3 0 A =6 3 0 6 3 1
8 0 0 A =8 0 0 8 0 1
Modellabelingmethod
HDC series MCCB
Product reference
numbers
Page 19
HDC series MCCB
400A frame and
accessory
Page 15
HDCCATAL STMF.indd 4 1/23/04 12:13:06 PM
-
7/28/2019 305 MCCB Hager Range
6/34
5
Product Selection Chart
Rated Insulation voltage
Ui (V)
125A 250A 400A 800A
690 V AC 690 V AC 690 V AC690 V AC
Breaking
capacity (kA)
H125TC
16 A
20 A
25 A
32 A
40 A
50 A
63 A80 A
100 A
125 A
HDA016A HDA017A
HDA020A HDA021A
HDA025A HDA026A
HDA032A HDA033A
HDA040A HDA041A
HDA050A HDA051A
HDA063A HDA064AHDA080A HDA081A
HDA100A HDA101A
HDA125A HDA126A
H125TD
HHA016A
HHA020A
HHA025A
HHA032A
HHA040A
HHA050A
HHA063A
HHA080A
HHA100A
HHA125A
H125TN
HNA016A
HNA020A
HNA025A
HNA032A
HNA040A
HNA050A
HNA063A
HNA080A
HNA100AHNA125A
HNA017A
HNA021A
HNA026A
HNA033A
HNA041A
HNA051A
HNA064A
HNA081A
HNA101AHNA126A
HHA017A
HHA021A
HHA026A
HHA033A
HHA041A
HHA051A
HHA064A
HHA081A
HHA101A
HHA126A
Rated
Current
/ A
H250TC
HHB125AHHB160A
HHB200A
HHB225A
HHB250A
H250TD
HHB126AHHB161A
HHB201A
HHB226A
HHB251A
HNB125A
HNB160A
HNB200A
HNB225A
HNB250A
HNB126A
HNB161A
HNB201A
HNB226A
HNB251A
H400TN
HNC250A
HNC320A
HNC400A
HNC251A
HNC321A
HNC401A
H800TN
HND500A
HND630A
HND800A
HND501A
HND631A
HND801A
16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A
125 A160 A
200 A
225 A
250 A
16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A125 A
160 A
200 A
225 A
250 A
250 A
320 A
400 A
500 A
630 A
800 A
18
25
35
50
Ref.No.
4 pole
Ref.No.
3 pole
Ref.No.
4 pole
Ref.No.
3 pole
Ref.No.
4 pole
Ref.No.
3 pole
Ref.No.
4 pole
Ref.No.
3 pole
HDCCATAL STMF.indd 5 1/23/04 12:13:18 PM
-
7/28/2019 305 MCCB Hager Range
7/34
Complies with IEC60947-2
standard
Rated current ranges from
16A to 800A
With four frame sizes for
selection
Easy to install and maintain
Compact structure, practical
functionality
Flexible and convenient
connection
Comprehensive specification,various function, wide
application
High reliability and safety
Number of poles for main
circuit: 3 poles and 4 poles
Adjustable 400 and 800 frame
electromagnetic release
125A frame
Rated current: 16A~125A
Breaking capacity: 18kA, 25kA,35kA
Rated insulation voltage: 690V
HDC Series Moulded Case Circuit Breaker
6
HDCCATAL STMF.indd 6 1/23/04 12:13:33 PM
-
7/28/2019 305 MCCB Hager Range
8/34
250A frame
Rated current: 125A~250A
Breaking capacity: 25kA,35kA
Rated insulation voltage: 690V
400A frame
Rated current: 250A~400A
Breaking capacity: 50kA
Flexible and adjustable
protection range
800A frameRated current: 500A~800A
Breaking capacity: 50kA
Flexible and adjustable
protection range
7
Draw-out type device
Available for 400A and 800A frame
Device with small volumeThree connection type
Meets functionality requirement,
with safety and reliability
Capable of connecting or
breaking main circuit and
secondary circuit
With safe and reliable interlock
function
HDCCATAL STMF.indd 7 1/23/04 12:13:46 PM
-
7/28/2019 305 MCCB Hager Range
9/34
Product Structure Of HDC Series
Moulded Case Circuit Breaker
1.HDC MCCB
2.Shunt trip
3.Undervoltage trip
4.a. Auxiliary switch
b. Alarm switch
c. Auxiliary/alarm switch
5.Rotary handle
6.Rotary handle accessory
7.Motor mechanism
8.Interphase barrier
9.Extended bus bar
10.Rear connection (fixed type)11.Rear connection (plug-in type)
12.Draw-out type device
Note: Item 2, 3, 4 are required
to be installed in factory. Please
contact the hager sales office or
agent when ordering.
3
9
5
5
11
10
7
8
4b
1
4a
4c
2
10
5
6
8
HDCCATAL STMF.indd 8 1/23/04 12:14:13 PM
-
7/28/2019 305 MCCB Hager Range
10/34
1
8
4b
2
3
1110
4a7
12 1
4c
5
5
6
5
9
9
HDCCATAL STMF.indd 9 1/23/04 12:14:34 PM
-
7/28/2019 305 MCCB Hager Range
11/34
10
HDCCATAL STMF.indd 10 1/23/04 12:14:34 PM
-
7/28/2019 305 MCCB Hager Range
12/34
Moulded Case Circuit Breaker
12 HDC series MCCB 125A frame
14 HDC series MCCB 250A frame
15 HDC series MCCB 400A frame
16 HDC series MCCB 800A frame
11
HDCCATAL STMF.indd 11 1/23/04 12:14:34 PM
-
7/28/2019 305 MCCB Hager Range
13/34
12
HDC Series MCCB 125A Frame
Frame type: H125TC,H125TD,
H125TN
Description:
Hager moulded case circuitbreaker provides various
options and wide choice for
the contractor, switch-board
manufacturer and distributor.
H125TC
Icu : 18 kA
Ue : 380/400 V AC
Ui : 690 V
16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A
125 A
1
1
1
1
1
1
1
1
1
1
HDA016A HDA017A
HDA020A HDA021A
HDA025A HDA026A
HDA032A HDA033A
HDA040A HDA041A
HDA050A HDA051A
HDA063A HDA064A
HDA080A HDA081A
HDA100A HDA101A
HDA125A HDA126A
H125TD
Icu : 25 kA
Ue : 380/400 V AC
Ui : 690 V
16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A
125 A
1
1
1
1
1
1
1
1
1
1
HHA016A
HHA020A
HHA025A
HHA032A
HHA040A
HHA050A
HHA063A
HHA080A
HHA100A
HHA125A
H125TN
Icu : 35 kA
Ue : 380/400 V AC
Ui : 690 V
16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A
125 A
1
1
1
1
1
1
1
1
1
1
HNA016A
HNA020A
HNA025A
HNA032A
HNA040A
HNA050A
HNA063A
HNA080A
HNA100A
HNA125A
HNA017A
HNA021A
HNA026A
HNA033A
HNA041A
HNA051A
HNA064A
HNA081A
HNA101A
HNA126A
HHA017A
HHA021A
HHA026A
HHA033A
HHA041A
HHA051A
HHA064A
HHA081A
HHA101A
HHA126A
102
86
104
Technical parameter:
Complies with IEC 60947-2
standard
Ultimate rated short-circuit
breaking capacityFrame 400V AC
H125TC 18kA
H125TD 25kA
H125TN 35kA
HHA016A
HNA126A
N
For technical information,see
page 17-29
Designation Pack
Qty
Current
Rating(A)
Ref.No.
4 pole
Ref.No.
3 pole
HDCCATAL STMF.indd 12 1/23/04 12:14:39 PM
-
7/28/2019 305 MCCB Hager Range
14/34
13
Shunt trip 24 V DC
24 V AC
110 V AC
230 V AC
400 V AC
HXA006A
HXA001A
HXA003A
HXA004A
HXA005A
Undervoltage trip 230 V AC
400 V AC
HXA014A
HXA015A
Auxiliary switch
Alarm switch
Auxiliary/Aalarm switch
1NO + 1NC
1NO + 1NC
1NO + 1NC / 1NO + 1NC
HXA021A
HXA024A
HXA023A
Rotary handle Selectable rotary handle accessory EH1/EH2
Selectable rotary handle accessory EH1/EH2
Selectable rotary handle accessory EH1/ EH2
HXA031A
HXA032A
HXA033A
Interphase barrier HYA020A
Rear connection Fixed type
Plug-in type
HYA031A
HYA041A
Motor
mechanism
HXA041A
HXA042A
24 V DC
110 V AC/DC 220 V AC/DC
HXA006A
HXA001A
HXA003A
HXA004A
HXA005A
HXA014A
HXA015A
HXA021A
HXA024A
HXA023A
HXA031A
HXA032A
HXA033A
HXA041A
HXA042A
HYA019A
HYA030A
HYA040A
HXA032A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
HXA004A
HXA031A
HXA033A
Designation Ref.No.
4 pole
Ref.No.
3 poleCharacteristics Pack
Qty
Installation
location.
For technical information,see
page 17-29
Frame type: H125TC,H125TD,
H125TN
Description:
Hager moulded case circuitbreaker provides various
options and wide choice for
the contractor, switch-board
manufacturer and distributor.
Technical parameter:
Complies with IEC 60947-2
standard
Ultimate rated short-circuit
breaking capacityFrame 400V AC
H125TC 18kA
H125TD 25kA
H125TN 35kA
HDC series MCCB 125A frame accessory
4 pcs (3 poles)/6 pcs (4 poles)
HDCCATAL STMF.indd 13 1/23/04 12:14:41 PM
-
7/28/2019 305 MCCB Hager Range
15/34
14
HDC Series MCCB 250A Frame
Frame type: H250TC,H250TD
Description:
Hager moulded case circuit
breaker provides variousoptions and wide choice for
the contractor, switch-board
manufacturer and distributor.
H250TC
Icu : 25 kA
Ue : 380/400 V AC
Ui : 690 V
125 A
160 A
200 A
225 A
250 A
1
1
1
1
1
HHB125A
HHB160A
HHB200A
HHB225A
HHB250A
H250TD
Icu : 35 kA
Ue : 380/400 V AC
Ui : 690 V
24 V DC
24 V AC
110 V AC
230 V AC
400 V AC
HXB006A
HXB001A
HXB003A
HXB004A
HXB005A
230 V AC
400 V AC
HXB014A
HXB015A
2NO + 2NC
1NO + 1NC
1NO + 1NC / 1NO + 1NC
HXB021A
HXB024A
HXB023A
HXB031A
HXB032A
HYB020A
HYB031A
HYB041A
HXB041A
HXB042A
24 V DC
110 V AC/DC 220 V AC/DC
HXB006A
HXB001A
HXB003A
HXB004A
HXB005A
HXB014A
HXB015A
HXB021A
HXB024A
HXB023A
HXB031A
HXB032A
HXB041A
HXB042A
HYB019A
HYB030A
HYB040A
HHB126A
HHB161A
HHB201A
HHB226A
HHB251A
HNB125AHNB160A
HNB200A
HNB225A
HNB250A
HNB126AHNB161A
HNB201A
HNB226A
HNB251A
Extended bus bar 6 pcs (3 poles)/8 pcs (4 poles) HYB013AHYB010A
86
104
Technical parameter:
Complies with IEC 60947-2
standard
Ult imate rated short-ci rcui t
breaking capacityFrame 400V AC
H250TC 25kA
H250TD 35kA
HYB019A
HDC series MCCB 250A frame accessory
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
125 A
160 A
200 A
225 A
250 A
1
1
1
1
1
HXB031A
1
HYB010A
N
For technical information,see
page 17-29
Designation Current
Rating(A)
Ref.No.
4 pole
Ref.No.
3 pole
Pack
Qty
Designation Ref.No.
4 pole
Ref.No.
3 pole
Characteristics Pack
Qty
Installation
location.
Shunt trip
Undervoltage trip
Auxiliary switch
Alarm switch
Auxiliary/Aalarm switch
Rotary handle Selectable rotary handle accessory EH1/EH2
Selectable rotary handle accessory EH1/EH2
Interphase barrier
Rear connection Fixed type
Plug-in type
Motor mechanism
HNB251A
4 pcs (3 ploes)/8 pcs (4 poles)
HDCCATAL STMF.indd 14 1/23/04 12:14:49 PM
-
7/28/2019 305 MCCB Hager Range
16/34
15
Frame type: H400TN
Description:
Hager moulded case circuit
breaker provides variousoptions and wide choice for
the contractor, switch-board
manufacturer and distributor.
H400TN
Icu : 50 kA
Ue : 380/400 V AC
Ui : 690 V
250 A
320 A
400 A
1
1
1
HNC250A
HNC320A
HNC400A
24 V DC
24 V AC110 V AC
230 V AC
400 V AC
HXC006A
HXC001AHXC003A
HXC004A
HXC005A
230 V AC
400 V AC
HXC014A
HXC015A
2NO + 2NC
1NO + 1NC
1NO + 1NC / 1NO + 1NC
HXC021A
HXC024A
HXC023A
HXC031A
HXC032A
HYC020A
HYC031A
HYC041A
HXC041AHXC042A
HXC043A
24 V DC
110 V AC/DC
220 V AC/DC
HXC006A
HXC001AHXC003A
HXC004A
HXC005A
HXC014A
HXC015A
HXC021A
HXC024A
HXC023A
HXC031A
HXC032A
HXC041AHXC042A
HXC043A
HYC019A
HYC030A
HYC040A
HNC251A
HNC321A
HNC401A
HYC013AHYC010A
Draw-out device Front connecting lineHorizontal
connecting lineVertical
connecting line
HYC043A
HYC046A
HYC047A
HYC042A
HYC044A
HYC045A
Technical parameter:
Complies with IEC 60947-2
standard
Ult imate rated short-ci rcui t
breaking capacity
131
697
103
5
5
47
Frame 400VAC
H400TN 50kA
HXC015A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
HNC400A
HXC023A
HXC004A
Designation Ref.No.
4 pole
Ref.No.
3 pole
Characteristics Pack
Qty
Installation
location.
HDC series MCCB 400A frame accessory
HDC Series MCCB 400A Frame
For technical information,see
page 17-29
Designation Current
Rating(A)
Ref.No.
4 pole
Ref.No.
3 pole
Pack
Qty
Extended bus bar 6 pcs (3 poles)/8 pcs (4 poles)
Shunt trip
Undervoltage trip
Auxiliary switch
Alarm switch
Auxiliary/Aalarm switch
Rotary handle Selectable rotary handle accessory EH1/EH2
Selectable rotary handle accessory EH1/EH2
Interphase barrier
Rear connection Fixed type
Plug-in type
Motor mechanism
4 pcs (3 poles)/6 pcs (4 poles)
HDCCATAL STMF.indd 15 1/23/04 12:15:00 PM
-
7/28/2019 305 MCCB Hager Range
17/34
16
Frame type: H800TN
Description:
Hager moulded case circuit
breaker provides variousoptions and wide choice for
the contractor, switch-board
manufacturer and distributor.
H800TN
Icu : 50 kA
Ue : 380/400 V ~
Ui : 690 V
500 A
630 A
800 A
1
1
1
HND500A
HND630A
HND800A
24 V DC
24 V AC
110 V AC
230 V AC
400 V AC
HXD006A
HXD001A
HXD003A
HXD004A
HXD005A
230 V AC
400 V AC
HXD014A
HXD015A
2NO + 2NC
1NO + 1NC
1NO + 1NC / 1NO + 1NC
HXD021A
HXD024A
HXD023A
HXD031A
HXD032A
HYD020A
HYD031A
HYD041A
HXD041A
HXD042A
HXD043A
24 V -
110 V AC/DC
220 V AC/DC
HXD006A
HXD001A
HXD003A
HXD004A
HXD005A
HXD014A
HXD015A
HXD021A
HXD024A
HXD023A
HXD031A
HXD032A
HXD041A
HXD042A
HXD043A
HYD019A
HYD030A
HYD040A
HYD013AHYD010A
HYD043A
HYD046A
HYD047A
HYD042A
HYD044A
HYD045A
HND501A
HND631A
HND801A
Technical parameter:
Complies with IEC 60947-2
standard
Ult imate rated short-ci rcui t
breaking capacity
7.5
32
103
6
34 8
14580.5
8
57
45
capacity IcuFrame 400V AC
H800TN 50kA
HYD040A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Note: For 800A frame, only rated current 800A is equipped with outgoing bus bar (refer to picture left).
HND800A
HYD030A
HXD042A
HDC Series MCCB 800A Frame
For technical information,see
page 17-29
Designation Current
Rating(A)
Ref.No.
4 pole
Ref.No.
3 pole
Pack
Qty
HDC series MCCB 800A frame accessory
Designation Ref.No.
4 pole
Ref.No.
3 pole
Characteristics Pack
Qty
Installation
location.
Draw-out device Front connecting l ineHorizontal
connecting lineVertical
connecting line
Extended bus bar 6 pcs (3 poles)/8 pcs (4 poles)
Shunt trip
Undervoltage trip
Auxiliary switch
Alarm switch
Auxiliary/Aalarm switch
Rotary handle Selectable rotary handle accessory EH1/EH2
Selectable rotary handle accessory EH1/EH2
Interphase barrier 4 pcs (3 poles)/6 pcs (4 poles)
Rear connection Fixed type
Plug-in type
Motor mechanism
HDCCATAL STMF.indd 16 1/23/04 12:15:13 PM
-
7/28/2019 305 MCCB Hager Range
18/34
17
Technical Data
20 Product description of HDC series MCCB
21 Product referencing
24 Dimension
25 Characteristic curve
27 Accessories
HDCCATAL STMF.indd 17 1/23/04 12:15:13 PM
-
7/28/2019 305 MCCB Hager Range
19/34
18
Product Description of HDC Series MCCB
a d
aa
bb b
c
Frame size
Model frame
Number of poles
Rated current (A)
Rated ambient temperature 400
Rated insulation voltage Ui (V)
Rated ultimate breaking capacity Icu (kA)
IEC60947-2EN 60947-2 400 V AC
External dimension (mm)
Weight (kg)
Standard function and characteristic
Trip Mechanism
Test button
Manual safety device (OFF-Lock)
*Only applicable for HXA/B/C/D033
Connection
method
Life
Front connection
125A 250A 400A 800A
h125tc, h125td, h125tn h250tc, h250td h400tn h800tn
3 4 3 4 3 4 3 4
16,20,25,32,
40,50,63,80,
100,125
125,160,
200,225,250
250
320
400
500
630
800
690 V AC
Icu / Ics
18 / 1425 / 1935 / 25
690 V AC 690 V AC 690 V AC
25 / 1935 / 25
50 / 35 50 / 35
Icu / Ics Icu / Ics Icu / Ics
a
b
c
d
aa
bb
155 165 260 273
86 86 103 103
104 104 130 145
30 35 45 70
132 126 214 243
90 120 105 140 140 173 210 279
1.4 1.9 1.8 2.4 5.3 7 9.4 12.5
Thermal-magnetic Thermal-magnetic Thermal-magnetic (adjustable)
8000 6000 3000 2500
10000 8000 6000 6000
Right
: Applicable (purchase additionally) : Not applicable
Thermal-magnetic (adjustable)
Rear connection
Plug-in type
Draw-out type
The following device can be installed additionally
Inte
rnal
acc
essory
External
accessory
Shunt trip SHT
Undervoltage trip UVT
Auxiliary switch AUX
Alarm switch ALM
Auxiliary alarm switch AUX+ALM
Motor mechanism
Rotary handle
Interphase barrier
Extended bus bar
Electrical endurance (no. of operation)
Mechanical endurance (no. of operation)
Right
Right
Right
Right
RightRight
Right
Right
Left
Left, right
Left, right
Left, right
LeftLeft
Left
Left
Left, right
Left
Left
HDCCATAL STMF.indd 18 1/23/04 12:15:16 PM
-
7/28/2019 305 MCCB Hager Range
20/34
19
Product Referencing of HDC Series MCCB
Product referencing of MCCB
1. Main product number
2. Product category&breaking capacity
D=16-18kA moulded case circuit breaker
H=25kA moulded case circuit breaker
N=35-50kA moulded case circuit breaker
X=auxiliary device
Y=accessory3. Frame type
A = 125 frame
B = 250 frame
C = 400 frame
D = 800 frame
4. Rated current
3 poles 4 poles
16A=016 017
20A=020 021
25A=025 026
32A=032 033
40A=040 041
50A=050 051
63A=063 064
80A=080 081
5. Serial
A=International
Note: If accessory is ordered with moulded case circuit breaker together, please fill in moulded case circuit breaker number and accessorynumber instead of product number on order sheet. If accessory is ordered individually, then only fill in accessory number. For example, to order125 frame 16A, 35kA and operating rotary handle device with central regulating crank structure, the product reference is HNA016D / HX031-EH1. if accessory is ordered individually, then it should be HX031-EH1.
SHT (shunt trip)
Shunt trip is used to switch off the
MCCB from a remote distance
Instantaneous mechanism
Operation characteristic (see table 1)
UVT (undervoltage trip)
Undervoltage trip is used to provide undervoltage
protection for circuit and electrical devices
Undervoltage trip can be used as remote tripping
operation
Characteristic (see table 2)
Shunt Trip SHT, Undervoltage Trip UVT
1. Main product number
Shunt trip (table 1)
Undervoltage trip (table 2)
Electrical accessory
Operating voltage range
Rated voltage
Electrical accessory
Operating voltage range
Guaranteed switch-on voltage
Guaranteed switch-off voltage
Shunt trip
(0.7-1.1)xUn
24VAC
(0.35-0.7)xUe
(0.85-1.17)xUe
0.35-Ue
24VDC
110VAC 230VAC 400VAC
230VAC 400VAC
H
H
2. Auxiliary device
3. Frame type
A = 125 frame
B = 250 frame
C = 400 frame
D = 800 frame
4. Voltage used
Shunt release: 006=24VDC001=24VAC
003=110VAC
004=230VAC
005=400VAC
Undervoltage release:
014=230VAC below
015=400VAC below
5. Serial
A=International
X
3 poles 4 poles
100A=100 101
125A=125 126
160A=160 161
200A=200 201
225A=225 226
250A=225 251
320A=320 321
400A=400 401
500A=500 501
630A=630 631
800A=800 801
HDCCATAL STMF.indd 19 1/23/04 12:15:17 PM
-
7/28/2019 305 MCCB Hager Range
21/34
20
Product Referencing of HDC Series MCCB
AUX auxiliary switch, ALM alarm switch, AUX+ALM auxiliary/alarm switch
1. Main product number
3. Frame type
A = 125 frame
B = 250 frame
C = 400 frame
D = 800 frame
4. Accessory type
021=Auxiliary switch
023=Alarm switch
024=Auxiliary/alarm switch
5. Serial
A=International
Auxiliary switch, alarm switch and auxiliary/alarm switchAuxilia ry switch is used as signal indicat ion for ON and OFFstatus of the MCCB.Alarm switch is used to send an alarm in case when the MCCBtripped on overload, short-circuit or via the shunt trip/under-voltagerelease operation.
H
1. Main product number
3. Frame type
C = 400 frame
D = 800 frame
4. Connection method
042: 3 poles front connecting line
043: 4 poles front connecting line
044: 3 poles horizontal connecting line
045: 3 poles vertical connecting line
046: 4 poles horizontal connecting line
047: 4 poles vertical connecting line
H
2. Auxiliary device
2. Accessory
Frame Size
125A, 250A, 400A, 800A
Rated Current of Switch
3A
Operating Voltage Ue
0.3A~0.4A 0.14~0.15A
380VAC 220VAC 220VDC 110VDC
1. Main product number
4. Rated voltage
041: DC 24V
* 042: 110V AC/DC
043: 220V AC/DC
H
Motor mechanism
2. Auxiliary device
*For 125 frame and 250 frame, 042 means rated voltage of 110V AC/DC and 220V AC/DC.
Draw-out device
Auxilia ry/alarm switch combines funct ion of auxilia ry switch andalarm switch.
switch, please see product description.
X
X
3. Frame type
A = 125 frame
B = 250 frame
C = 400 frame
D = 800 frame
5. SerialA=International
5. Serial
A=International
HDCCATAL STMF.indd 20 1/23/04 12:15:18 PM
For detailed information of available auxiliary switch and alarm
-
7/28/2019 305 MCCB Hager Range
22/34
21
1. Main product number
H
2. Auxiliary device
3. Frame type
A = 125 frame
B = 250 frame
C = 400 frame
D = 800 frame
4. Accessory type
031 = Circular panel rotary handle device
032 = Rectangular panel rotary handle device
033 = Rectangular panel rotary handle device
(high protection)
5. Rotary handle accessory
EH1= Centered regulating
crank structure
EH2=Eccentric connecting rod
structure
X
1. Main product number
4. Connection type
030: 3 poles fixed type
040: 3 poles plug-in type
031: 4 poles fixed type
041: 4 poles plug-in type
H
2. Accessory
1. Main product number
4. Rated voltage
041: DC 24V
* 042: 110V AC/DC
043: 220V AC/DC
H
Extended bus bar
2. Accessory
Rear connection
Y
Y
3. Frame type
B = 250 frame
C = 400 frame
D = 800 frame
1. Main product number
4. No. of poles
019: 3P
020: 4P
H
Interphase barrier
2. Accessory
Y
3. Frame type
A = 125 frame
B = 250 frame
C = 400 frame
D = 800 frame
Product Referencing of HDC Series MCCB
3. Frame type
A = 125 frame
B = 250 frame
C = 400 frame
D = 800 frame
A
5. Serial
A=International
5. Serial
A=International
5. Serial
A=International
Rotary handle
HDCCATAL STMF.indd 21 1/23/04 12:15:19 PM
-
7/28/2019 305 MCCB Hager Range
23/34
22
Dimension of HDC Series MCCB
125A frame
Front cut-out size 3 poles
55
28
R1
132
155
90
30
M4X0.7
Fixed Screw
N
132
155
120
60
102
86
104
52
28
R2
165
126
M4X0.7Fixed Screw
35
105
165
126
70
140
86
104
R2
92
64
M6X0.7Fixed Screw
260
140
45
131
129
108
106
260
173
135
45
131
129
108
106
N
45
131
6
97103
55
47
92
64
M8X0.7Fixed Screw
141
70
210
132
80
70
80
40
126
117
70 70
141
279
132
80
80
126
117
7.5
32
103
6
348
14580.5
8
57
45
4 poles Lateral face
250A frame
Front cut-out size 3 poles 4 poles Lateral face
400A frame
Front cut-out size 3 poles 4 poles Lateral face
800A frame
Front cut-out size 3 poles 4 poles Lateral face
HDCCATAL STMF.indd 22 1/23/04 12:15:29 PM
-
7/28/2019 305 MCCB Hager Range
24/34
23
Characteristic Curve of HDC Series MCCB
16
20
32
40
50
60
80
100
125
208 42
260 52416 83
520 104
650 130
819 164
975 195
1300 260
1625 325
125160
200
225
250
1594 281
2040 360
2550 450
2869 5063188 563
125A release curve 250A release curve
400A release curve 800A release curve(In:500A - 630A)
4
3
2
1504030
20
10
8
654
3
2
15040
30
20
10
865
43
2
10.80.60.50.4
0.3
0.2
0.10.08
0.060.050.04
0.03
0.02
0.010.008
0.0060.005
08
09
001
521
002
052
003
004
005
006
007
008
009
0001
0051
0002
0052
0003
0004
0005
0006
0007
0008
051
DNOCES
ETUNIM
RUOH
500 5000500
X5 X10
630 6300630
Trip current value
There are 5 phases that canbe adjusted within adjustablerange of electromagnet trip
Rated current(A)
h800t
TrippingTime
% of rated current in comparison
Trip current value(A) (x10)
Min
Max
4000400
Trip current value
3200320
2500250
400
250
320
0.010.008
0.0060.005
0.10.080.060.05
0.03
0.02
0.04
0.80.60.50.40.3
0.2
NOCES
D
1
10
2
43
8
56
504030
20
1
2
10
ETUNIM
4
3
56
8
4030
50
RU
OH
1
3
2
4
20
09
08 01
021
551
002
052
003
004
005
006
007
0 0001
09
008
0 0051
0052
0002
0003
0004
0005
0008
0007
0006
Min
LO HI There are 5 phases that canbe adjusted within adjustablerange of electromagnet trip
Rated current(A)
h400tn
Max
TrippingTime
% of rated current in comparison
Trip current value(A)
16A~32A Max
40A~125A Max
20A~32A Min
40A~125A Min
Trip current value
Rated current(A) Trip Current (A)
Trip current value
Rated current(A) Trip Current (A)
TrippingTime
TrippingTime
% of rated current in comparison % of rated current in comparison
HDCCATAL STMF.indd 23 1/23/04 12:15:33 PM
-
7/28/2019 305 MCCB Hager Range
25/34
24
125A frame Temperaturecompensation curve
Standardambienttemperature
16A,20A,40A,80A
32A,100A,125A
63A
130
125
120
115
110
105
100
90
0 10 20 30 40 50 60
Ratedcurrent(%)
Ambient tem erature CO
125A,160A,200A
225A,250A
130
125
120
115
110
105
100
90
0 10 20 30 40 50 60
Standardambienttemperature
Ratedcurrent(%)
Ambient temperature( C)O
0 10 20
90
100
110
120
130
30 40 50 60
320,400A
250A
Standardambienttemperature
Ratedcurrent(%)
Ambient temperature( C)O
630A
10
90
0
100
4020 30 50 60
)110
120
130
500A Standardambienttemperature
Ratedcurrent(%)
Ambient temperature( C)O
0 10
90
100
110
800A
20 30 40 50 60
120
130
Standardambienttemperature
Ratedcurrent(%)
Ambient temperature( C)O
800A release curve(In:800A)
001
0.0060.005
08
09
0.03
0.008
0.01
0.02
0.060.05
0.04
0.1
0.08
4
40
0.5
0.2
0.4
0.3
DNOCES
1
0.8
0.6
2
10
4
3
8
65
20
30
3
1
50
2
ETUNIM
654
10
8
20
50
40
30
RUOH
2
1
3
X10X5
008
003
521
051
002
052
005
004
006
007
0001
009
0051
0002
0004
0052
0003
0005
0006
0007
0008
800 8000800
Trip current value
There are 5 phases that canbe adjusted within adjustablerange of electromagnet trip
Rated current(A)
h800t
TrippingTime
% of rated current in comparison
Trip current value(A) (x10)
Min
Max
Characteristic Curve of HDC Series MCCB
250A frame Temperaturecompensation curve
400A frame Temperaturecompensation curve
800A frame Temperature
compensation curve(In:500A - 630A)
800A frame Temperature
compensation curve(In:800A)
HDCCATAL STMF.indd 24 1/23/04 12:15:35 PM
-
7/28/2019 305 MCCB Hager Range
26/34
25
HDC Series MCCB Accessory
42
65
65
4.5
200
45
53
36
2- 5.50200
61
H
93
93
H
Ref. No.
HXA031A
HXB031A
HXC031A
HXD031A
H
65
65
95
95
H
65
65
95
95
HXA032A
HXB032A
HXC032A
HXD032A
OFF position can be installed with
padlocking device (applicable for HX*033)
Optional accessory
Standard configured with EH1 rotary handle
device
HXC031
HXC032
Install on distribution
enclosure door
Protection level:
HX*031/HX*032 IP30
HX*033 IP65
Rotary handle
Ref. No.
HDCCATAL STMF.indd 25 1/23/04 12:15:36 PM
-
7/28/2019 305 MCCB Hager Range
27/34
26
Frame
125A
250A
400A
800A
H
56
57
62
73
125A
250A400A
800A
H A B
46
4655
55
42
4268
67
11.5
11.515
15
EH1 rotary handle accessory
Centered regulating crank
mechanism, using plastic roller
belt
Breaker handle is easy tooperate, with less friction force.
Reset indication is accurate and
flexible, with long service life
Y
Y
X X
H
20
24
D
MIN = 50mm
H
16
24
D
MIN = 50mm
Y
B
X
A
YA
X
X
Y
B
H
16
24
D
MIN = 50mm
EH2
EH1
HDC Series MCCB Accessory
Rotary handle With guide orientationto prevent misoperation or
overhead operation which may
cause breaker handle broken
High reliabilityOne device with three handles
available to select
EH2 rotary handle
Accessory adopts eccentric
type connecting rod mechanism,
save space
One device with three handlesavailable to select
Frame
HDCCATAL STMF.indd 26 1/23/04 12:15:40 PM
-
7/28/2019 305 MCCB Hager Range
28/34
27
Compact structure, small
size, easy to install, capable of
manual operation. The product
adopts advanced switch power
technology, its mechanicaland electrical life ensures high
reliability.
Both AC/DC power can be
used, with wide voltage control
range and small working current
With colored sign (red, green
and white) to indicate ON, OFF
125A Frame
Ref. No.
HXA041A
A
HXA042A
B C d E H Mechanical life(times)
30 132 90 4.5 116 89.5 14000
HXB041A
A
HXB042A
B C d E H
35 143 90 4.5 116 93 10000
HXC041A
A
HXC042A
B C d E H1
45 213 130 6.5 176 129 5000
HXD041A
HXD042A 800A Frame
CH1
H2
A
P1 P2 S1 S2 S4
ON OFF
SRZHU
Uc
4-d
E lec tric dr iv in gmechani sm
B
EWarning
1.It should be operated with 180 in clockwise directionwhen performing manual operation.Anti clock wise op-erationis prohibited.2.Whendoing pressure resistance test:place betweenline entry terminal P1 & P2 (exclude S1, S2 andS4) ofpower supply andinstallation bolt of electric operationcan resist AC 50Hz, 1500V power frequency pressureresistance test.3.When rated voltage of electric operationis DC24V,pressure resistance test is not allowed.
Manual operation handle
H
E
A
4-d
P1 P2 S1 S2 S4
C
BB
ON OFFUc
Warning1.It should be operated with 180 in clockwise directionwhen performing manual operation. Anti clock wise op-eration is prohibited.2.When doing pressure resistance test:place betweenline entry terminal P1 & P2 (exclude S1, S2 and S4) ofpower supply and installation bolt of electric operation
can resist AC 50Hz, 1500V power frequency pressureresistance test.3.When rated voltage of electric operation is DC24V,pressure resistance test is not allowed.
Manual operationhandle
SRZHU
E lec tr ic d r iv in gmechani sm
H
E
A
4-d
P 1 P 2 S 1 S 2 S 4
C
BB
ON OFFUc
Warning1.It should be operated with 180 in clockwise directionwhen performing manual operation. Anti clock wise op-eration is prohibited.2.When doing pressure resistance test:place betweenline entry terminal P1 & P2 (exclude S1, S2 and S4) ofpower supply and installation bolt of electric operationcan resist AC 50Hz, 1500V power frequency pressureresistance test.3.When rated voltage of electric operation is DC24V,pressure resistance test is not allowed.
Manual operation handle
SRZHU
E lec tr ic d r iv in gmechani sm
Motor mechanism
70 243 130 0.2 176 146 5000
H2
129
136.5
HXC043A
HXD043A
125A Frame
400A & 800A Frame
HDC Series MCCB Accessory
and TRIPPED
status
250A Frame
Applicablebreaker
250A Frame
Ref. No. Mechanical life(times)
400A Frame
Ref. No. Mechanical life(times)Applicable
breaker
Applicablebreaker
HDCCATAL STMF.indd 27 1/23/04 12:15:43 PM
-
7/28/2019 305 MCCB Hager Range
29/34
28
Draw-out
device
This device adopts lever
principle. With push handle, easy
to insert and pull out.
Main circuit and secondary
circuit can be connected ordisconnected
With safe and reliable interlock
function. When MCCB is not
installed properly in draw-out
device, breaker is unable to
switch on.
When breaker is pulled out from
draw-out device, MCCB will
automatically trip and cut off
power supply.
With temporary isolation andclear isolation function. When
MCCB is drawn-out, there is
grounding bolt installed on
side board to prevent electrical
leakage.
3P
4P
Pole
303
303
L1
332
332
L2
196
196
L3 H1
17.5
11
H2
77
77
H3
44
44
W1
211
255
W2
253
d1
88
88
A
11
253 17.5
B d2
141
141
6.5
6.5
800A Frame
3P
4P
387 410 241 1373 70 289 140238 26 131 6.5
387 410 241 1373 70 359 140238 26 131 6.5
3L
H3
H2
H1
Frontconnection
Rearconnection
2L
1L
d
W1 W1
W2
B
A
23
d
HYC042A
HYC044A
HYC045A
HYC043A
HYC046A
HYC047A
HYD042A
HYD044A
HYD045A
HYD043A
HYD046A
HYD047A
400A Frame
Ref. No. External dimensionApplicablebreaker
Installation size
HDC Series MCCB Accessory
Three connection method: with
characteristic of cost effective,
safe, reliable, etc.
HDCCATAL STMF.indd 28 1/23/04 12:15:47 PM
-
7/28/2019 305 MCCB Hager Range
30/34
29
Rear connection Rear connection used formoulded case circuit breaker
enhances isolation function
between MCCB and main circuit.
It has the characteristic of easyinstallation, reliable
External dimension (mm) and installation size of rear connection (fixed type)
HYA030A
HYB030A
HYC030A
HYD030A
125A Frame
250A Frame
92
108
146
205
A
60
70
88
178
A1
30
38
52
45
B
70
74
145
158
B1
102
108
177
198
C D
-
10
D1
134
145
227
243
E
M10
25
28
44
F
13
13
18.5
57
G
26
34
37
43
H
16
15
20
20
H1
M10
6
8
16
J
65
79
78
88
K1
126
134
130
148
K2
60
70
88
140
L
M5
M5
M8
M8
M
13
13
6
10
10
6
1K
2K
D1
F
B
B
C
L
A
D A1
1B
E
J
M
H1
HG
HYA031A
HYB031A
HYC031A
HYD031A
122 90 30 70 - 134 M10 13 26 16 M10 65 126 60 M56
143 105 38 74 145 25 13 34 15 6 79 134 105 M56
190 132 52 145 10
102
108
177
10
13 227 28 18.5 37 20 8 78 130 132 M8
275 248 45 158 198 243 44 57 43 20 16 88 148 210 M81310
3
4
3
4
3
4
3
4
HYA040A
HYB040A
HYC040A
HYD040A
92
108
146
212
A
60
70
88
140
A1
30
38
52
57
B
70
74
145
143
B1
102
108
177
184
C D
-
10
D1
134
145
227
243
E
M10
25
28
44
F
13
13
18.5
57
G
26
34
37
43
H
16
15
20
20
H1
M10
6
8
16
J
65
79
78
129
K1
126
134
130
-
K2
60
70
88
140
L
M5
M5
M8
M8
M
13
13
6
10
10
6
HYA041A
HYB041A
HYC041A
HYD041A
122 90 30 70 - 134 M10 13 26 16 M10 65 126 60 M56
143 105 38 74 145 25 13 34 15 6 79 134 105 M56
190 132 52 145 10
102
108
177
10
13 227 28 18.5 37 20 8 78 130 132 M8
282 210 57 143 184 243 44 57 43 20 16 129 - 210 M81310
3
4
3
4
3
4
3
4
HDC Series MCCB Accessory
contact, small insert & pull force
and low temperature rise.
External dimension (mm) and installation size of rear connection (plug-in type)
Pole Ref. No.External dimensionand insallation sizeApplicable
breaker
Pole Ref. No.External dimension and insallation sizeApplicable
breaker
400A Frame
800A Frame
125A Frame
250A Frame
400A Frame
800A Frame
HDCCATAL STMF.indd 29 1/23/04 12:15:53 PM
-
7/28/2019 305 MCCB Hager Range
31/34
30
Notes
HDCCATAL STMF.indd 30 1/23/04 12:15:53 PM
-
7/28/2019 305 MCCB Hager Range
32/34
31
Notes
HDCCATAL STMF.indd 31 1/23/04 12:15:53 PM
-
7/28/2019 305 MCCB Hager Range
33/34
32
Notes
HDCCATAL STMF.indd 32 1/23/04 12:15:53 PM
-
7/28/2019 305 MCCB Hager Range
34/34
The success is in the system
Hager Electro SAS
132, boulevard d'EuropeB.P. 3F-67215 Obernai CedexFrance
Tel : +(33) 3 88 49 50 50
Fax : +(33) 3 88 49 51 44http://www.hager.com