Transcript
Page 1: 3ps1202 TDSsheets 4565 US...4565 2 Storage and Disposal • Store in dry, clean conditions in original packaging • Store away from direct sunlight, sources of high temperature, and

Description The 3M™ Protective Coverall 4565 is designed to help protect against hazardous dusts (Type 5), light liquid splashes (Type 6), and low pressure liquid sprays (Type 4).

The key features include:

• Constructedofalow-linting,non-woven,laminatedmaterialwithanti-staticcoating on both sides

• Knitcuffswithelasticizedwaistandanklesforincreasedwearercomfortandfreedomofmovement

• ThreepanelhooddesignforcompatibilitywithcomplementaryPPE

• Two-wayzipperwithsealablestormflap

• Tapedseamstohelpprovideadditionalprotection

• Offersprotectionfromcertainbiologicalcontaminants(testedaccordingto EN14126).Consultclassresultstable.

Materials•Suit:Polypropylene/PolyethyleneLaminateFilm,White

•Zipper:NylononPolyesterBraid

•Elastic:NeopreneRubber

•Cuffs:Polyester

•Thread:Polyester

•Seams:Polypropylene,Red

•BasisWeight:49grams/m2

Thisproductdoesnotcontaincomponentsmadefromnaturalrubberlatex.

ApprovalsCEapprovedunderPPEDirective(89/686/ECC),CategoryIII. Article10Certification:BTTGTesting&CertificationLtd.NotifiedBodyNumber:0338.Article11BSupervision:SGSUnitedKingdom,LTD. NotifiedBodyNumber:0120.

Comfort and Protection

*Inthewholesuittest,liquidsprayisappliedtothesubjectfor1minute.Duringthistimethesubjectmovesgentlyandisrotatedthrough360°.Atotalof4.56litersissprayedfromfournozzles.Theclothingisallowedtodrainfor2minutesandthentheabsorbentcoverallisinspectedforstainswhicharecomparedtoacalibrationstain.Requirement:Passeswhenthestainedareainsideis3timessmallerthanthecalibrationstainarea.

**Allapparelmustbegroundedforanti-statictreatmenttobeeffective.Electrostaticpropensitymaydecreasewithwearingtimeand/orsevereconditions.

***Exceptpunctureresistance.

Applications and Performance

*Contact3Mforadditionalchemicalpermeation,penetrationandrepellencydata.

3M™ Protective Coverall 4565

Technical4565DataSheet

Typical Applications Typicalapplicationsmayincludeexposuretoradioactiveparticles,exposuretonon-infectiousbloodandbodilyfluids,waterreactivepowderhandling,tankcleaningandmaintenance,pharmaceutical,cleanroomapplications,andgeneralindustrialclean-up.

Inallcasesariskassessmentshouldbecarriedout.Usersmustbetrainedandhaveread all User Instructions.Uselimitationsandperformancedatashouldbeconsideredtoascertaintheprotectionrequired.Ifindoubt,contactasafetyprofessional.

PerformanceThetablebelowshowstheperformanceofthisproductwhentestedunderlaboratoryconditions.Pleasenotethatthetestsmaynotreflecttherealityofuseanddonotaccountforfactorssuchasexcessiveheatandmechanicalwear.

*ThestandardsEN13034:2005andENISO13982-1:2004,andEN1073-2:2002defineperformanceclasses.

**ThemaximumClassis6unlessotherwisenoted.

***TheEuropeanStandardENISO6530measuresliquidpenetrationthroughafabricandliquidrepellencybyafabric.Thetestsimulatesexposuretosmallamountsofchemicals(10ml)for1minutedurationonly.Thepenetrationindexreferstothepercentageoftheoriginalquantitywhichpenetratesthefabricwithin1minute(inadetectorbeaker)asapercentage of the original quantity.

Liquid Protection Type4(EN14605)andType6(EN13034). Wholesuitreducedspraytest(ENISO17491-4)*

Dust Protection Type5(ENISO13982-1).InwardLeakageresults: Ljmn,82/90<30%;LS,8/10<15%.

Anti-static Anti-staticcoatingonbothsides(EN1149-1:2006/EN1149-5:2008)**

Nuclear Radioactiveparticulates(EN1073-2:2002),Class2***.Doesnotofferprotection against radiation.

Biohazard TestedaccordingtoASTMF1670andEN14126:2003(seeclassdatain test table)

Non-Hazardous Particulates Yes Gases and Vapors No

Non-Hazardous Liquid Splash Yes Hazardous

Liquid Splash Contact3Mforchemicalcompatibilitydata

Non-Hazardous Liquid Spray Yes Hazardous Low

Pressure Liquid SprayYes,ifchemicaliscompatiblewith suitmaterial*

Hazardous Dusts and Fibers Yes Organic Solvents Contact3Mforchemicalcompatibilitydata

Liquid Continuous Contact/Immersion No Acids/Alkalis Yes,ifchemicaliscompatiblewith

suitmaterial*

Test Standard Result Standard* Class**/ Result

Abrasion ASTMD4157 CyclestoRupture 850 EN530 Class1

FlexCracking ISO7854 Class1

TearResistanceTrapezoidal ASTMD5733(warpdirection/filldirection)

16lbf/ 8lbf ISO9073-4 Class1

TensileStrength ASTMD751,Section11,ProcedureA(longitude/traverse)

15lbs/ 21lbs ISO13934-1 Class1

PunctureResistance ASTMD2582(MD/CD) 46N/26N EN863 Class1

BurstingResistance ASTMD751,Section18 86N ISO13938-1 Class1

ResistancetoIgnition CPSC16CFRPT1610 Class1 EN13274-4 Pass

SeamStrength ASTMD751,Section66(PeakLoad/SeamStrength)

10lbf/ 5lbf/in ENISO13935-2 Class2

HydrostaticResistance ASTMD751,ProcedureB >1479mm

RepellencytoLiquids***–30%H2SO4

ENISO6530 Class 3 of 3

LiquidPenetrationResistance***–30%H2SO5

ENISO6530 Class 3 of 3

RepellencytoLiquids***–10%NaOH ENISO6530 Class 3 of 3

LiquidPenetrationResistance***–10%NaOH ENISO6530 Class 3 of 3

Anti-staticCoatingon BothSides

EN1149-1:2006/EN1149-5:2008

Pass

RadioactiveParticulates EN1073-2 Class2of3

SyntheticBlood PenetrationResistance ASTMF1670 Pass ISO16603 Class 6

Blood-bornePathogenPenetrationResistance ISO16604 Class0

ContaminatedSolidParticlePenetrationResistance ENISO22612 Class 3 of 3

ContaminatedLiquidAerosol Penetration Resistance

ENISO22611 Class 3 of 3

WetBacteriaPenetrationResistance ENISO22610 Class 6

Page 2: 3ps1202 TDSsheets 4565 US...4565 2 Storage and Disposal • Store in dry, clean conditions in original packaging • Store away from direct sunlight, sources of high temperature, and

Permeation Data per ASTM F739

*Normalizedbreakthroughtime.DefinedbyASTMF739asthetime(inminutes)whenthepermeationratereaches 0.1ug/cm2/min.Breakthroughtimesof<10minutesarelistedasimmediate.Datarepresentsinglesamples.

**Foradditionalchemicalpermeationandpenetrationdata,pleasecontactyourlocal3MTechnicalServiceRepresentative.

Use LimitationsDonotusefor:

• Contactwithheavyoils,sparksorflames,orcombustibleliquids

• Exposuresituationsresultingindirectionalsprayorliquidbuild-uponthesuit

• Environmentswithhighmechanicalrisks(abrasions,tears,cuts)

• Environmentswithexposuretohazardoussubstancesbeyond CEType4/5/6certification

• Environmentswithconditionsofexcessiveheat

4565

2

Storage and Disposal• Storeindry,cleanconditionsinoriginalpackaging

• Storeawayfromdirectsunlight,sourcesofhightemperature,andsolventvapors

• Storewithinthetemperaturerange-20°Cto+25°C(-4°Fto+68°F)andwithrelativehumiditybelow80%

• Shelflifeisthreeyearsfromdateofmanufacturewhenstoredasstatedabove

• Replacegarmentsifdamaged,heavilycontaminatedorinaccordancewithlocal work practice

• Handleanddisposeofcontaminatedgarmentswithcareandinaccordancewith national regulations

LimitedUse Donottumbledry

Donotwash Donotdry-clean

Donotbleach Flammable—keepaway

fromsparksorflames Donotiron

Productmustneverbealteredormodified.

Height Chest

M 66–69in 167–176cm 36–39in 92–100cm

L 69–71in 174–181cm 39–43in 100–108cm

XL 70–74in 179–187cm 43–45in 108–115cm

XXL 73–76in 186–194cm 45–49in 115–124cm

3XL 76–78in 194–200cm 49–52in 124–132cm

4XL 78–81in 200–206cm 52–55in 132–140cm

SizingAnappropriatesizegarmentshouldbeselectedtoallowsufficientmovementforthetask.MeetsANSI101-1996(R2008)sizingguidelines.

Protective Coveralls 4565

Fabric Type Polypropylene,PolyethyleneLaminate

Chemical CAS Breakthrough time*(min)

Permeation Rate(ug/cm2/min)

Acetone 67-64-1 Immediate 12

Acetonitrile 75-05-8 Immediate 17

CarbonDisulfide 75-15-0 Immediate 611

Dichloro-methane 75-09-2 Immediate 27

Diethylamine 109-89-7 Immediate 587

Dimethyl-formamide 68-12-2 Immediate 4

EthylAcetate 141-78-6 Immediate 304

n-Hexane 110-54-3 Immediate 34

Methanol 67-56-1 Immediate 2.2

Nitrobenzene 98-95-3 Immediate 13

Sodiumhydroxide,50% 1310-73-2 >480 ND

SulphuricAcid,93-98% 7664-93-9 412 3

Tetrachloro-ethylene 127-18-4 Immediate 866

Tetra-hydrofuran 109-99-9 Immediate 23

Toluene 108-88-3 Immediate 15

Occupational Health and Environmental Safety Division3M Center Building235-2NW-70 St.Paul,MN55144-1000

3M Canada Company OH&ESDP.O.Box5757 London,OntarioN6A4T1 Canada

For More InformationTechnicalAssistanceinU.S. 1-800-243-46303M.com/PPESafetyTechnicalAssistanceinCanada 1-800-267-4414 3M.ca/PPESafety

3Misatrademarkof3M, used under license in Canada. Pleaserecycle.PrintedinUSA.©3M2012.Allrightsreserved.75-0501-0418-3

Formoreinformationon3Mproductsandservicespleasecontact3M.Important Notice

Thisguideisonlyanoutline.Itshouldnotbeusedastheonlymeansforselectingprotectiveclothing.Beforeusinganyprotectiveclothing,thewearermustreadandunderstandtheuserinstructionsforeachproduct.Specificcountrylegislationmustbeobserved.Ifindoubt,contactasafetyprofessional.SectionsofthemostappropriatePPEwilldependontheparticularsituationandshouldonlybemadebyacompetentpersonknowledgeableoftheactualworkingconditionsandthelimitationsofPPE.

Finaldeterminationastothesuitabilityoftheseproductsforaparticularsituationistheuser’sresponsibility.Thisinformationissubjecttorevisionatanytime.Alwaysreadandfollowall User Instructions supplied with your 3M™ProtectiveCoverallsinordertoensurecorrectoperation.Ifyouhavequestionscontact3MTechnicalService.

WARRANTY: 3M will replace or refund the purchase price of any Occupational Health and Environmental Safety Division (OH&ESD) product found to be defective in material, manufacture, or not in conformance with any express warranty. This warranty is exclusive and is in lieu of any implied warranty of merchantability or fitness for a particular purpose.

LIMITATION OF LIABILITY: Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, indirect, incidental, special or consequential rising out of the sale, use or misuse of 3M OH&ESD products, or the user’s inability to use such products. THESE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE.


Top Related