AA
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
® AA-01
Walkways
Building Entrances
Parking Lots
Shopping Malls
The fixture shall be ETL and CETL listed for wet location.
The luminaire shall meet the specified light distribution and footcandle levels with an internal optical system.
Field assembly to pole or bracket shall be accomplished without having to remove or disassemble any components. Fixture shall be ETL listed “suitable for wet locations.”
Ballast shall be readily accessible, removable and insulated. The fixture is to be pre-wired, completely assembled and electronically tested prior to shipment. Quick disconnects are standard.
The optical assembly shall be of all non-ferrous components. Lens panels shall be of impact resistant acrylic, and fixture shall be fully gasketed to prevent entry of moisture, dust and insects.
BK-BZ-WH-GR-GY-NA baked enamel standard, other colors available.
Standard fitter is for 3” O.D. pole top. If tenon is required, specify exact tenon dimension and dimensions of round or square pole tops to ensure compatibility.
Certifications
Light Distribution
Assembly
Ballast
Optical Assembly
Finish
Mounting Detail
Specifications
AA
PROJECTFIXTURE TYPECATALOG#
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
© Architectural Landscape Lighting 2004 Due to a program of continuous improvement, Architectural Landscape Lighting reserves the right to make any variation in design or construction to the equipment described.
ALLSCAPE is a registered trademark of Architectural Landscape Lighting
AA-01
Max Lamp LampSeries Size Watts Type Voltage1 Optics Finish1 OptionsAA-01 22 (up to 175 W) 175 MH E-172 120 TOA BZ Bronze HSS House Side Shield 24 (up to 175 W) 250 MH ED-28 208 TCA BK Black PCB Button Photo Control 30 (up to 250 W) 175 HPS E-172 240 OA WH White F Fusing 42 (up to 250 W) 250HPS ED-18 277 OP GR Green FF Double Fusing CLF NA Natural Aluminum WM Wall Mount CLL GY Gray DL Downlight3
CC Custom Color UL Uplight3
1 Consult factory for other colors and voltages
2 Lamps 175 W and below are medium base.
3 30" head size only
Example: AA-01-22-150HPS-E17-120-OA-BK-PCB
OpticsTOA Textured Opal AcrylicTCA Textured Clear AcrylicOA Opal AcrylicOP Opal PolycarbonateCLF Type 5 Refractor W/Clear LensCLL Louver Assembly W/Clear Lens
Luminaire A B Weight EPAAA-01-22 10-1/8" 22" 40# 2.2AA-01-24 15" 24" 44# 2.4AA-01-30 15" 30" 50# 2.9AA-01-42 15" 42" 62# 4
A
B
Luminaire Dimensions
NOTE:AA-01-30 Shown with Windows
Product Order Guide
GE Consumer & IndustrialLighting
ConstantColor® CMH®
150 Watt Open-RatedElliptical Lamps
Uniform,Consistent Color
GE ConstantColor CMH ceramic metal halide lamps provide lamp-to-lamp color uniformity, consistent excellent color over life… plus high operating efficiencies.
GE - Innovative, Energy-Saving Lighting
Color uniformity lamp-to-lampCeilings will look clean and bright, with minimal color variation lamp-to-lamp. ConstantColor CMH provides a consistent “white look”, critical for interior applications.
Consistent color over lifeGE ConstantColor CMH lamps provide stable color over life. So walls, ceilings, displays and furnishings look their natural best always.
Excellent color renderingWarm white light (3000K) and exceptional color rendering (>80 CRI) make ConstantColor CMH an ideal source for indoor applications.
Ease of useProtective shroud allows for use of product in open-fixtures.
Highly efficientUp to 85 lumens per watt - 10-20% more efficient than standard metal halide.
12,000 to 15,000 hour rated life
Fits standard metal halide socketsNo new wiring or fixtures needed.
imagination at work
ConstantColor® CMH® 150 Watt Open-Rated Elliptical Lamps Clear 150-Watt 4K
M102CMH150/U/MED/942/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")8 (5/16")
4001903°3°
Open or Enclosed Fixture
150952.41.81.8
120009000
15000>90 4200K
5 Max18 Max.372.372
31067Coated 150-Watt 4K
M102CMH150/C/U/MED/942/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 3 (3/8")
138 (5 7/16")8 (5/16")
4001903°3°
Open or Enclosed Fixture
150952.41.81.8
110008250
15000>90 4200K
5 Max18 Max.372.372
31068Product Information*
Product CodeRefer to ANSI CodeDescriptionPhysical CharacteristicsBurn PositionBulb DesignationBulb MaterialBulb Nominal Diameter, mm (inches)Base TypeLight Center Length, mm (inches)Max. Overall Length, mm (inches)Effective Arc Length, mm (inches)Max. Bulb Temp C° Max. Base Temp C° Eccentricity: Base-to-BulbEccentricity: Base-to-Arc AxisLuminaire CharacteristicsElectrical/Photometric CharacteristicsNominal Lamp WattsNominal Lamp VoltsNominal Lamp Amps-StartingNominal Lamp Amps-OperatingMax. Current Crest FactorInitial LumensMean Lumens (40% Rated Life)Rated Life (Hrs.) 10 Hrs./StartColor Rendering Index (Ra) CRI@KWarm-up time (Minutes) to 90%Hot Restart Time (Minutes) to 90%Chromaticity Coordinates: XChromaticity Coordinates: Y*All data are engineering estimates
Clear 150-Watt 3K
M102CMH150/U/MED/830/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")8 (5/16")
4001903°3°
Open or Enclosed Fixture
150952.41.81.8
129009545
12000>80 3000K
3 Max19 Max
.438
.397
31065Coated 150-Watt 3K
M102CMH150/C/U/MED/830/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 3 (3/8")
138 (5 7/16")8 (5/16")
4001903°
Open or Enclosed Fixture
150952.41.81.8
119008805
12000>80 3000K
3 Max19 Max
.438
.397
31066
3°
WARNING - These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured and the arc tube continues to operate. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain types of lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available from the General Electric Company. If the outer envelope breaks or is punctured and the lamp continues to operate, immediately turn power off and remove lamp after it has cooled. These lamps are certified to comply with FDA radiation performance standards, 21 CFR Subchapter J.
Spectral Power Distribution - 3000K Lamp Spectral Power Distribution - 4200K Lamp
Wavelength (nm)
0
20
40
60
80
100
Rela
tive
Inte
nsity
400 500 600 700 800450 550 650 750
Rela
tive
Inte
nsity
100
80
60
40
20
0400 500 600 700 800450 550 650 750
Wavelength (nm)
Lamp Mortality Lumen Maintenance100 100
90 90
% L
umen
s
% S
urvi
ving 80 80
70 70
60 60
50 50
Operating Hours (Percent of Rated Life)0 20 40 60 80 100
Operating Hours (Percent of Rated Life)0 20 40 60 80 100
For additional product and application information, please consult GE’s Website: www.gelighting.com
ConstantColor and CMH are registered trademarks of the General Electric Company.
28333-2004 Printed in USA
P&
B
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
®
PROJECTFIXTURE TYPECATALOG#
© Architectural Landscape Lighting 2004 Due to a program of continuous improvement, Architectural Landscape Lighting reserves the right to make any variation in design or construction to the equipment described.
ALLSCAPE is a registered trademark of Architectural Landscape Lighting
RAS
Round Aluminum Straight PolesCatalog Pole Bolt Anchor Max.Number Dimensions Circle Bolt Size EPARAS-4011-8 4” O.D. x 8’ 7 1/2” (4) 5/8” x 18” 6.8RAS-4011-10 4” O.D. x 10’ 7 1/2” (4) 5/8” x 18” 4.7RAS-4011-12 4” O.D. x 12’ 7 1/2” (4) 5/8” x 18” 3.2RAS-4011-14 4” O.D. x 14’ 7 1/2” (4) 5/8” x 18” 1.9
RAS-5011-12 5” O.D. x 12’ 8 3/8” (4) 3/4” x 30” 8.9RAS-5011-14 5” O.D. x 14’ 8 3/8” (4) 3/4” x 30” 6.8RAS-5011-16 5” O.D. x 16’ 8 3/8” (4) 3/4” x 30” 5.3RAS-5011-18 5” O.D. x 18’ 8 3/8” (4) 3/4” x 30” 2.4
Tenon Options Options2-3/8" O.D. T2 GFI GFI Provision Only2-7/8" O.D. T33-1/2" O.D. T3.54" O.D. T4
Drill Mount Options Hand HoleDM 10 Single 12" to center from base approx.DM 2180 Double at 180 DegDM 2090 Double at 90 DegDM 3090 Triple at 90 DegDM 4090 Quad at 90 Deg Note:EPA calculation is with 100 mph wind and 1.3 gust factor. Base cover, anchor bolts, and hand hole cover included
Grout
Hex Nuts,Washers,
Bolts.Anchor
Concrete Footing
2-3/4”
BoltCircle7.5”
RAS4
Grout
Hex Nuts,Washers,
Bolts.Anchor
Concrete Footing
3-1/2”
BoltCircle8-3/8”
RAS5
LL
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660Fax: 714 668 [email protected]://www.alllighting.com
® LL-02
Low Level Lighting
6” Round Aluminum Bollard
Landscape Accent
Walkways
Building Entrances
Planter Areas
Parks
Parking Lots
The fixture shall be ETL and CETL listed for wet location.
The LL-02 luminaire shall meet the specified light distribution and footcandle levels with an internal optical system.
The fixture shall be factory pre-wired, with high temperature wire completely assembled and tested prior to shipment. Field installation to mounting base shall be accomplished without having to remove or disassemble any fixture components. Fixture shall be ETL listed “suitable for wet locations.”
The housing shall be constructed from 6” diameter one piece extruded 6063 alloy aluminum tube.
Ballast shall be readily accessible, removable and insulated. Quick disconnects are standard.
Clear or opal 1/4” thick polycarbonate.
The specified optical system shall be of all non-ferrous components, mounted and removable as a one-piece self-contained unit.
BK-BZ-WH-GR-GY-NA baked enamel standard, other colors available. Anodized finish also available.
Certifications
Light Distribution
Assembly
Housing
Ballast
Lens
Optical Assembly
Finish
Specifications
LL
PROJECTFIXTURE TYPECATALOG#
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660Fax: 714 668 [email protected]://www.alllighting.com
© Architectural Landscape Lighting 2004 Due to a program of continuous improvement, Architectural Landscape Lighting reserves the right to make any variation in design or construction to the equipment described.
ALLSCAPE is a registered trademark of Architectural Landscape Lighting
LL-02
Max Lamp Optical OverallSeries Watts Type Voltage1 System Height Finish1 OptionsLL-02 70 MH E-17 120 O 30” BZ Bronze F Fusing 70 HPS E-17 208 CLF 36” BK Black FF Double Fusing 26 CFQ CFQ2 240 CLR3 42” GR Green HSS House Side Shield 42 CFT CFT2 277 GY Gray EMG Emergency Battery Backup 13 CF CF2 WH White HDBP Heavy Duty Base Plate CC Custom Color NA Natural aluminum BAA Clear Anodized BZA Bronze Anodized BKA Black Anodized1 Consult factory for other colors and voltages
2 CF = single biax, CFQ = double biax, CFT = triple biax
3 CLR 26CFT max
Example: LL-02-70HPS-E17-120-CLR-42-BZ-PL
Luminaire A B WeightLL-02 6” 30” 20# 6” 36” 24# 6” 42” 26#
DISTANCE IN FEET0
0
3
3
6
6
1212
9
9
DIS
TA
NC
E I
N F
EE
T
21
0.5
0.2
0.1
5
A
B
DISTANCE IN FEET0
0
3
3
6
6
1212
9
9
DIS
TA
NC
E I
N F
EE
T
10
5
21
0.5
DISTANCE IN FEET0
0
3
3
6
6
1212
9
9
DIS
TA
NC
E I
N F
EE
T
10
105
21
0.5
0.2
LL-02-70HPS-O-36Clear Lamp5,800 Lumens36" Mounting HeightISOLUX Curves—value in initial footcandles
LL-02-70HPS-CLF-36Clear Lamp5,800 Lumens36" Mounting HeightISOLUX Curves—value in initial footcandles
LL-02-70HPS-CLR-36Clear Lamp5,800 Lumens36" Mounting HeightISOLUX Curves—value in initial footcandles
Photometric Data
Product Order Guide
Luminaire Dimensions
4.000 DIA. BOLT CIRCLE(CAST ALUM BASE PLATE)
BASE PLATE
GROUT
SECURINGSCREW
CONDUITOPENNING
Anchor Bolt Size(2) 1/2" x 12" x 3"
TM
e-Vision® Electronic Ballast for Metal Halide Lamps
Catalog Number IMH-70-A-BLS-ID For 70W Metal Halide Lamps ANSI M98, M143 or M139 120-277V 50/60Hz Electronic Status: Released
DIMENSIONS AND DATA Lamp Data
Number Watts Input Volts
Catalog Number*
Line Current (Amps)
Input Power
(W)
Ballast Factor
Max THD (%)
Min Power Factor
Wiring Dia Figure Weight
(lb)
Max Distance to Lamp
(ft)
70W Watt Lamp, ANSI Code M98, M143 or M139 Minimum Starting Temp -30°C/-20°F
120 0.72 86
1 70
277
IMH-70-A-xxx-ID
0.31 84
1.0 18% 0.9 8 A 1.5 5
*Ordering Information Order Suffix Description
-BLS Ballast with bottom exit leads and mounting studs
INSTALLATION & APPLICATION NOTES: 1. Use with any Thermal Protector having equivalent resistive value 5k
to 25k ohm (4 wire versions only) 2. Open Circuit voltage across ID output approx 270VDC 3. Maximum allowable case temperature is 90°C. See figure above
for measurement location 4. Ignition pulse is 4 kV max 5. All leads are 12 inches long 6. Ballast output will shutdown after 20 minutes if lamp fails to ignite 7. Power must be cycled off – then on, after replacing lamp
Data is based on tests performed by Advance transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
Advance • 10275 West Higgins Road • Rosemont, Illinois 60018-5603 • (847) 390-5000 • fax: 847-390-5109 • www.advancetransformer.com
A DIVISION OF PHILIPS ELECTRONICS NORTH AMERICA CORPORATION
9/29/06
Figure A
CASE LENGTH = 4.72” [120mm] MOUNTING LENGTH = 5.20” [132mm] MOUNTING WIDTH = 2.87” [73mm] OVERALL LENGTH = 5.51” [140mm] CASE WIDTH = 3.62” [92mm] HEIGHT = 1.50” [38mm] Ballast will not operate if Insulation
Detector is Absent, Shorted or Failed Open
GE Consumer & IndustrialLighting
ConstantColor® CMH®
70 Watt Open-RatedElliptical Lamps
Uniform,Consistent ColorGE ConstantColor® CMH® ceramic metal halide
lamps provide lamp-to-lamp color uniformity, consistent excellent color over life… plus high operating efficiencies.
GE - Innovative, Energy-Saving Lighting
Color uniformity lamp-to-lampCeilings will look clean and bright, with minimal color variation lamp-to-lamp. ConstantColor® CMH® provides a consistent “white look”, critical for interior applications.
Consistent color over lifeGE ConstantColor® CMH® lamps provide stable color over life. So walls, ceilings, displays and furnishings look their natural best always.
Excellent color renderingWarm white light (3000K) and exceptional color rendering (>80 CRI) make ConstantColor® CMH® an ideal source for indoor applications.
Ease of UseProtective shroud allows for use of product in open-fixtures.
Highly efficientUp to 75 lumens per watt- 10-20% more efficient than standard metal halide.
Up to 16,000 hour life
Fits standard metal halide socketsNo new wiring or fixtures need.
GE imagination at work
ConstantColor® CMH® 70 Watt Open-Rated Elliptical Lamps Coated 70-Watt 3K
M98CMH70/C/U/MED/830/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.853003900
16000>80 3000K
3 Max15 Max
.438
.397
31070Clear 70-Watt 4K
M98CMH70/U/MED/942/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.852003700
16000>90 4200K
3 Max15 Max
.372
.372
31073Coated 70-Watt 4K
M98CMH70/C/U/MED/942/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.846003600
16000>90 4200K
3 Max15 Max
.372
.372
31074Clear 70-Watt 3K
M98CMH70/U/MED/830/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.858004000
16000>80 3000K
3 Max15 Max
.438
.397
31069Product Information*
Product CodeRefer to ANSI CodeDescriptionPhysical CharacteristicsBurn PositionBulb DesignationBulb MaterialBulb Nominal Diameter, mm (inches)Base TypeLight Center Length, mm (inches)Max. Overall Length, mm (inches)Effective Arc Length, mm (inches)Max. Bulb Temp ° CMax Base Temp ° CEccentricity: Base-to-BulbEccentricity: Base-to-Arc AxisLuminaire CharacteristicsElectrical/Photometric CharacteristicsNominal Lamp WattsNominal Lamp VoltsNominal Lamp Amps-StartingNominal Lamp Amps-OperatingMax. Current Crest FactorInitial LumensMean Lumens (40% Rated Life)Average Rated Life (Hrs.) 10 Hrs./StartColor Rendering Index (Ra) CRI@KWarm-up time (Minutes) to 90%Hot Restart Time (Minutes) to 90%Chromaticity Coordinates: XChromaticity Coordinates: Y*All data are engineering estimates
WARNING - These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured and the arc tube continues to operate. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain types of lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available from the General Electric Company. If the outer envelope breaks or is punctured and the lamp continues to operate, immediately turn power off and remove lamp after it has cooled. These lamps are certified to comply with FDA radiation performance standards, 21 CFR Subchapter J.
Spectral Power Distribution - 3000K Lamp
Wavelength ( nm )
0
20
40
60
80
100
Rela
tive
Inte
nsity
400 500 600 700 800450 550 650 750
Spectral Power Distribution - 4200K Lamp
Wavelength ( nm )
0
20
40
60
80
100
Rela
tive
Inte
nsity
400 500 600 700 800450 550 650 750
Lamp Mortality Lumen Maintenance100 100
90 90
% L
umen
s
% S
urvi
ving 80 80
70 70
60 60
50 50
Operating Hours (Percent of Rated Life)0 20 40 60 80 100
Operating Hours (Percent of Rated Life)0 20 40 60 80 100
For additional product and application information, please consult GE’s Website: www.gelighting.com28328-2004 Printed in USA
SP
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
® SP-108/109/110
SP
SP
Corridors
Walkways
Accent and
General Lighting
SP-108
SP-109 SP-110
The fixture shall be ETL and CETL listed for wet location and concrete pour with a protection rating of IP65, dust-tight and jet-water proof. The fixture shall meet ADA requirements.
The housing shall be constructed of die cast aluminum with two 1/2" NPT conduit entrances for through-wiring capability.
The ballast shall be readily accessible, removable and insulated. The fixture is to be pre-wired and electronically tested before shipment.
The lens shall be prismatic frosted glass or opal polycarbonate (SP-108 andSP-109). The lens shall be clear glass (SP-110).
All exposed hardware shall be stainless steel.
BK-BZ-WH-GR-GY-NA baked enamel standard, other colors available.
Certifications
Housing
Ballast
Lens
Hardware
Finish
IP65ADA
Specifications
MET
RIC
SP
© Architectural Landscape Lighting 2006 Due to a program of continuous improvement, Architectural Landscape Lighting reserves the right to make any variation in design or construction to the equipment described.
PROJECTFIXTURE TYPECATALOG#
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
ALLSCAPE is a registered trademark of Architectural Landscape Lighting
SP
SP-108/109/110
SP-108 SP-109 SP-110
SP-108-(2)13CF-GL1,720 Lumens3.0 ft Mounting HeightISOLUX Curves - value in initial footcandles
SP-110-13CF-BK860 Lumens3.0 ft Mounting HeightISOLUX Curves - value in initial footcandles
SP-109-60INC-GL890 Lumens3.0 ft Mounting HeightISOLUX Curves - value in initial footcandles
AB
C
D
AB
C
D
AB
C
D
Luminaire A B C D Weight Inch mm Inch mm Inch mm Inch mm lbs. kgSP-108 10.63 270 3.94 100 9.72 247 1.18 30 7.1 3.2SP-109 10.63 270 3.94 100 9.72 247 1.57 40 7.1 3.2SP-110 10.63 270 3.94 100 9.72 247 1.97 50 6.7 3.0
Product Order Guide Max LampSeries Watts Type Voltage1 Finish1 OptionSP-108 / SP-109 60 Halogen3 BT15 120 BK Black GL Prismatic Frosted Lens 60 INC T10 208 BZ Bronze PL Polycarbonate Lens 13 CF CF2 240 WH White 2(13) CF CF2 277 GR Green 26 CFQ CFQ2 NA Natural Aluminum 42 CFT CFT2 GY Gray CC Custom Color
SP-110 75 Halogen T3mini 13 CF CF2
26 CFQ CFQ2
26 CFT CFT2
1 Consult factory for other colors and voltages
2 CF = single biax, CFQ = double biax, CFT = triple biax
3 GL option only
Example: SP-108-13CF-120-BK-PL
Photometric Data
Luminaire Dimensions
Revised 08/15/2006
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
ICF-2S18-H1-LD@120Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamp
s
Rated
Lamp
Watts
Min. Start
Temp
(°F/C)
Input
Current
(Amps)
Input
Power
(ANSI
Watts)
Ballast
Factor
MAX
THD
%
Power
Factor
MAX Lamp
Current
Crest Factor
B.E.F.
CFM18W/GX24Q 1 18 0/-18 0.17 20 1.05 10 0.97 1.5 5.25
* CFM18W/GX24q 2 18 0/-18 0.33 39 1.05 10 0.99 1.5 2.69
CFQ18W/G24Q 1 18 0/-18 0.16 19 1.00 10 0.97 1.5 5.26
CFQ18W/G24q 2 18 0/-18 0.30 35 0.95 10 0.99 1.5 2.71
CFS16W/GR10q 2 16 0/-18 0.31 37 1.00 09 0.99 1.5 2.70
CFS21W/GR10Q 1 21 0/-18 0.16 20 0.90 15 0.97 1.5 4.50
CFS21W/GR10Q 2 21 0/-18 0.33 40 0.91 10 0.99 1.5 2.28
Wiring Diagram
WIRING: (2) LAMPS (1) LAMP
Green Terminal must be Grounded
GREEN
BLACK
WHITE BALLASTLINE
BLUE
RED
YELLOW
RED
BLUE
The wiring diagram that appears above is
for the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 0.0
White 0.0
Blue 0.0
Red 0.0
Yellow 0
Gray
Violet
in. cm.
Yellow/Blue
Blue/White
Brown
Orange
Orange/Black
Black/White
Red/White
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
4.98 " 2.4 " 1.0 " 4.6 "
4 49/50 2 2/5 1 4 3/5
12.6 cm 6.1 cm 2.5 cm 11.7 cm
ICF-2S18-H1-LD@120Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Notes:
Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements.
1.3 Ballast shall be provided with poke-in wire trap connectors color coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Programmed Start except for ballasts with -QS suffix, which shall be Rapid Start.
2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with
no damage to the IntelliVolt ballast. RCF models shall operate from 60 Hz input source of 120V with sustained variations of +/- 10% (voltage
and frequency) with no damage to the ballast.
2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices
and eliminate visible flicker.
2.5 Ballast shall have a Power Factor greater than 0.98 for primary lamp.
2.6 Ballast shall have a minimum ballast factor of 1.00 for primary lamp application.
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations.
2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.9 Ballast shall have a Class A sound rating.
2.10 Ballast shall have a minimum starting temperature of -18C (0F) for primary lamp. Ballasts for PL-H lamps shall have a minimum starting
temperature of -30C (-20F) for primary lamp.
2.11 Ballast shall provide Lamp EOL Protection Circuit.
2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall be Underwriters Laboratories (UL) rated for use in air-handling spaces.
3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.5 Ballast shall comply with ANSI C82.11 where applicable.
3.6 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated) except for RCF models which shall be Consumer (Class B).
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 75C and three-years for a maximum case temperature of 85C (90C 3year warranty for ICF1H120-M4-XX, ICF2S42-90C-M2-XX and ICF2S70-M4-XX modesls).
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
4.4 Ballast shall be Advance part # _____________ or approved equal.
Revised 08/15/2006
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018TELEPHONE: (847) 390-5000 FAX: (847) 390-5109
GE Consumer & IndustrialLighting
Fast Warm-Up, Plug-In CFL Triple Biax® LampsGE provides faster warm-up times on the fast growing, very popular line of 4-pin plug-in CFL Triple Biax® Lamps
50% faster warm upGE’s new 4-pin plug-in Triple Biax lamps warm up to full brightness 50% faster and provide immediate flicker-free light.
Outstanding energy efficienciesAs much as 77% energy cost savings vs. incandescent lamps. The 42-watt delivers 3200 lumens, 12% more than a standard 150-watt incandescent bulb!
TCLP CompliantAll GE 4-pin plug-in Triple Biax lamps feature low mercury and are TCLP compliant in both the U.S. and Canada.
Long Life – 12,000 hoursGE Biax Lamps last up to 16 times longer than standard incandescent bulbs. Longer life means lower lamp replacement and maintenance costs.
Excellent Color – 82 CRIGE’s SPX color provides excellent color rendering. Available in a choice of color temperatures: 2700K, 300K, 3500K and 4100K.
DimmableGE 4-pin plug-in Triple Biax lamps can be operated on dimming circuits for greater application and design flexibility.
GE – bringing incandescentfeatures to compactfluorescent lamps
GE - Innovative, Energy-Saving Lighting
imagination at work
Fast Warm-Up, Plug-In CFL Triple Biax® LampsColor Lamp Initial Rated TCLP
Watts Temperature Description P/C Lumens CRI Life Compliant
13 2700K F13TBX/SPX27/A/4P 34391 900 82 12,000 Yes3000K F13TBX/SPX30/A/4P 34395 900 82 12,000 Yes3500K F13TBX/SPX35/A/4P 34400 900 82 12,000 Yes4100K F13TBX/SPX41/A/4P 34387 900 82 12,000 Yes
18 2700K F18TBX/SPX27/A/4P 34392 1200 82 12,000 Yes3000K F18TBX/SPX30/A/4P 34396 1200 82 12,000 Yes3500K F18TBX/SPX35/A/4P 34405 1200 82 12,000 Yes4100K F18TBX/SPX41/A/4P 34385 1200 82 12,000 Yes
26 2700K F26TBX/SPX27/A/4P 34393 1710 82 12,000 Yes3000K F26TBX/SPX30/A/4P 34397 1710 82 12,000 Yes3500K F26T8X/SPX3S/A/4P 34406 1710 82 12,000 Yes4100K F26TBX/SPX41/A/4P 34381 1710 82 12,000 Yes
32 2700K F32TBX/SPX27/A/4P 39377 2200 82 12,000 Yes3000K F32TBX/SPX30/A/4P 39378 2200 82 12,000 Yes3500K F32TBX/SPX35/A/4P 39379 2200 82 12,000 Yes4100K F32TBX/SPX41/A/4P 39380 2200 82 12,000 Yes
42 2700K F42TBX/827/A/4P/EOL 46312 3200 82 12,000 Yes3000K F42TBX/830/A/4P/EOL 46313 3200 82 12,000 Yes3500K F42TBX/835/A/4P/EOL 46314 3200 82 12,000 Yes4100K F42TBX/841/A/4P/EOL 46315 3200 82 12,000 Yes
Nominal Lamp Dimension - Inches (mm)
Lamp Type
F13TBX/08F18TBX/23F26TBX/33F32TBX/48F42TBX/54
A
4.25 (108)4.84 (123)5.24 (133)5.83 (148)6.06 (154)
B
2.60 (66)3.19 (81)3.58 (91)4.17 (106)4.37 (111)
C
.80 (19)
.80 (19)
.80 (19)
.80 (19)
.79 (20)
D
1.93 (49)1.93 (49)1.93 (49)1.93 (49)2.28 (58)
E
.59 (15)
.59 (15)
.59 (15)
.59 (15)
.59 (15)
For additional product and application information, please consult GE’s Website:
www.gelighting.com
49713 – 3/2005 Printed in USA
SL
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
® SL-50
ETL and CETL listed for wet location. Also meets IP55 standard.
Die-cast aluminum with die cast aluminum swivel that allows a 75˚ vertical tilt adjustment on the Up/Down, wall mount and Spike mount housings and 165˚ vertical tilt adjustment on Curved pole and Straight pole housings.
Die cast aluminum mounted to lamp housing with three stainless steel cap screws. Clear flat tempered glass is standard.
Porcelain 2-pin GX5.3.
Transformer is integral with all versions when 120 or 277 is specified. Standard transformer is electronic with 120 or 277 volt primary and 12 volt secondary.
The following options are available: Wall mount curved arm (CA); Wall mount up/down dual head (UD), ground mount mini straight post (SP) and (SM) Spike mount.
BK-BZ-WH-GR-GY-NA baked enamel standard, other colors available.
Caution: Care should be taken when specifying fixtures for use in pedestrian areas to avoid problems that may be caused by high lens temperatures. Consult factory for more information.
Certifications
Lamp Housing
Lens Ring
Lampholder
Transformer Housing
Options
Finish
Safety
Landscape Areas
Building Accent
Pedestrian Areas
Tree Lighting
Low Voltage
CIE
LLO
CA - Curved Arm UD - Up/Down SP - Straight Post
Specifications
© Architectural Landscape Lighting 2004 Due to a program of continuous improvement, Architectural Landscape Lighting reserves the right to make any variation in design or construction to the equipment described.
SL
PROJECTFIXTURE TYPECATALOG#
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
ALLSCAPE is a registered trademark of Architectural Landscape Lighting
®
SL-50
Max LampSeries Watts Type Voltage Finish OptionsSL-50 50LV MR-16 12 BK Black UD2 Up/Down Mount 1201 BZ Bronze SP Straight Post 2771 WH White CA6 Curved Arm GR Green SA6 Straight Arm NA Natural Alum. CP Curved Post GY Gray SP2 Straight Post CC Custom Color JBRS3 Surface Mount Junction Box JBRC Conduit Mount Junction Box JBRTM Tree Mount Junction Box STNM Stanchion Mount LP Low Post (Plastic)1 Note 120/277 uses transformer PTB5 Portable 120/12v2 The U/D option requires a single gang 2” x 4” junction box. SM4 Spike Mount 3 The JBRS option requires a 4” octagonal junction box. HSL Horizontal Spread Lens4. The SM option is available for LV (12V) and PTB applications only. VSL Vertical Spread Lens5 The PTB option is available for 120V portable applications only and must be connected to a GFI outlet.6 Specify Junction Box Mounting or Surface Conduit Connection
Example: SL-50-120-BK-UD
Luminaire A B C D E Weight Inch mm Inch mm Inch mm Inch mm Inch mm lbs kgSL-50-SP 3.5” 89 29.5” 750 4”SQ 102 0.5”OD 13 2”OD 51 2.5 1.1SL-50-SA 20” 508 5.125” 130 4.750” 120 2.250“ 57 n/a n/a 2.5 1.1SL-50-CA 22” 559 13” 330 4.750” 120 2.250” 57 n/a n/a 2.5 1.1SL-50-SM 3.875” 98 4.875” 124 12.875” 327 n/a n/a n/a n/a 1.25 .5SL-50-PTB 5.125” 130 5.875” 149 13.875” 352 n/a n/a n/a n/a 1.75 .8SL-50-JBRS 5.125” 130 5.875” 149 3.250” 82 4.750” 120 n/a n/a 1.5 .7SL-50-UD 5.250” 133 3.250” 82 7” 178 1.625” 41 8” 203 3.0 1.4
Luminaire Dimensions
SL-50-PTB
SL-50-SP
SL-50-12-SM
Consult Ciello Application Brochure For More Options
A
E
D
C
B
AA
A
A
A A
BBB
B
B
C
CC
C
C
C
D
D
D
D
E
B
SL-50-JBRS
SL-50-UDSL-50-CA-JBRS
SL-50-SA-JBRS
Product Order Guide
SITE SEARCH HOME PRODUCTS EDUCATION / RESOURCES LIGHTING APPLICATIONS
Where to Buy | FAQs | Contact Us | EliteNet
16720 – Q50MR16/HIR/CG40 GE MR16
CAUTIONS & WARNINGS
See list of cautions & warnings.
Energy Savings
GENERAL CHARACTERISTICSLamp type Halogen - MRBulb MR16Base 2-Pin (GU5.3) Filament C-8Wattage 50Voltage 12Voltage (MIN) 50Rated Life 4000 hrsRated Life (Vert) 4000 hrs
PHOTOMETRIC CHARACTERISTICSInitial Lumens 2600Initial Lumens (Hor) 2600Initial Lumens (Vert) 2600Center Beam Candlepower (CBCP)
2600
Color Temperature 3000 KNominal Initial Lumens per Watt 52
DIMENSIONSMaximum Overall Length (MOL) 1.8000 in (45.7 mm)
PRODUCT INFORMATIONProduct Code 16720Description Q50MR16/HIR/CG40Standard Package CaseStandard Package GTIN 10043168167205Standard Package Quantity 20Sales Unit UnitNo Of Items Per Sales Unit 1No Of Items Per Standard Package
20
UPC 043168167208
View Larger
ADDITIONAL RESOURCES Catalogs Testimonials Sell Sheets
Precise™ IR Energy Saving MR16 Halogen Lamp MSDS (Material Safety Data Sheets) Disposal Policies & Recycling Information
Bulb Base
Page 1 of 216720 - Specifications - GE Commercial Lighting Products
4/6/2007http://genet.gelighting.com/LightProducts/Dispatcher?REQUEST=COMMERCIALSPECPAGE&PRODU...
Return To Top
Home | Products | EliteNet | Education/Resources | Lighting Applications | Where to Buy | FAQs | Contact Us | Site Map Products for Your Home | Press Room | Corporate | Investor Information | Privacy Policy | Accessibility Statement | Terms of Use
Copyright General Electric Company 1997-2007
Page 2 of 216720 - Specifications - GE Commercial Lighting Products
4/6/2007http://genet.gelighting.com/LightProducts/Dispatcher?REQUEST=COMMERCIALSPECPAGE&PRODU...
BL
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
® BL-44/45/4748/49
BL
Building Mount
Corridor
Walkways
Accent
Building Entrances
The fixture shall be ETL and CETL listed for wet location. Also meets IP65 standard.
Cast aluminum with a minimum thickness of 1/8”. Mounting plate welded to ballast housing for J-box mounting. Conduit mounting available, consult factory. Housing is fully gasketed with 3/16” extruded EDPM cord gasket.
Cast aluminum mounted to ballast housing with 1/4-20 stainless steel allen cap screws.
Opal UV-stabilized polycarbonate (OP) is standard. Lens supplied with one-piece extruded silicone gasket.
Maximum HID-70 watts with polycarbonate lens. Fluorescent ballast for 42CFT lamp is electronic (minus 20° C). Other fluorescent 13- through 26-watt quad tube is core & coil (0° C).
BK-BZ-WH-GR-GY-NA baked enamel standard, other colors available.
Certifications
Ballast Housing
Lens Frame
Lens
Ballast
Finish
BL-44 BL-45
BL-48 BL-49BL-47
Specifications
BL
PROJECTFIXTURE TYPECATALOG#
2930 South Fairview StreetSanta Ana, CA 92704Phone: 714 668 3660 Fax: 714 668 [email protected]://www.alllighting.com
© Architectural Landscape Lighting 2004 Due to a program of continuous improvement, Architectural Landscape Lighting reserves the right to make any variation in design or construction to the equipment described.
ALLSCAPE is a registered trademark of Architectural Landscape Lighting
Max LampSeries Watts Type Voltage1 Lens Finish1 OptionsBL-44 (2)26 CFQ CFQ2 120 OP Opal Polycarbonate BK Black EMG Emergency Battery BackupBL-45 26 CFQ CFQ2 208 BZ BronzeBL-47 42 CFT CFT2 240 WH WhiteBL-48 70 MH E-17 277 GR GreenBL-49 70 HPS E-17 NA Natural Aluminum GY Gray CC Custom Color
1 Consult factory for other colors and voltages
2 CF = single biax, CFQ = double biax, CFT = triple biax
Example: BL-48-70MH-E17-277-OP-WH
Luminaire A B CBL-44 14” 8” 7-1/2”BL-45 14” 8” 7-1/2”BL-47 14” 8” 7-1/2”BL-48 14” 8” 7-1/2”BL-49 14” 8” 7-1/2”
A C
B
BL-44/45/4748/49
Luminaire Dimensions
Product Order Guide
TM
e-Vision® Electronic Ballast for Metal Halide Lamps
Catalog Number IMH-70-A-BLS-ID For 70W Metal Halide Lamps ANSI M98, M143 or M139 120-277V 50/60Hz Electronic Status: Released
DIMENSIONS AND DATA Lamp Data
Number Watts Input Volts
Catalog Number*
Line Current (Amps)
Input Power
(W)
Ballast Factor
Max THD (%)
Min Power Factor
Wiring Dia Figure Weight
(lb)
Max Distance to Lamp
(ft)
70W Watt Lamp, ANSI Code M98, M143 or M139 Minimum Starting Temp -30°C/-20°F
120 0.72 86
1 70
277
IMH-70-A-xxx-ID
0.31 84
1.0 18% 0.9 8 A 1.5 5
*Ordering Information Order Suffix Description
-BLS Ballast with bottom exit leads and mounting studs
INSTALLATION & APPLICATION NOTES: 1. Use with any Thermal Protector having equivalent resistive value 5k
to 25k ohm (4 wire versions only) 2. Open Circuit voltage across ID output approx 270VDC 3. Maximum allowable case temperature is 90°C. See figure above
for measurement location 4. Ignition pulse is 4 kV max 5. All leads are 12 inches long 6. Ballast output will shutdown after 20 minutes if lamp fails to ignite 7. Power must be cycled off – then on, after replacing lamp
Data is based on tests performed by Advance transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
Advance • 10275 West Higgins Road • Rosemont, Illinois 60018-5603 • (847) 390-5000 • fax: 847-390-5109 • www.advancetransformer.com
A DIVISION OF PHILIPS ELECTRONICS NORTH AMERICA CORPORATION
9/29/06
Figure A
CASE LENGTH = 4.72” [120mm] MOUNTING LENGTH = 5.20” [132mm] MOUNTING WIDTH = 2.87” [73mm] OVERALL LENGTH = 5.51” [140mm] CASE WIDTH = 3.62” [92mm] HEIGHT = 1.50” [38mm] Ballast will not operate if Insulation
Detector is Absent, Shorted or Failed Open
GE Consumer & IndustrialLighting
ConstantColor® CMH®
70 Watt Open-RatedElliptical Lamps
Uniform,Consistent ColorGE ConstantColor® CMH® ceramic metal halide
lamps provide lamp-to-lamp color uniformity, consistent excellent color over life… plus high operating efficiencies.
GE - Innovative, Energy-Saving Lighting
Color uniformity lamp-to-lampCeilings will look clean and bright, with minimal color variation lamp-to-lamp. ConstantColor® CMH® provides a consistent “white look”, critical for interior applications.
Consistent color over lifeGE ConstantColor® CMH® lamps provide stable color over life. So walls, ceilings, displays and furnishings look their natural best always.
Excellent color renderingWarm white light (3000K) and exceptional color rendering (>80 CRI) make ConstantColor® CMH® an ideal source for indoor applications.
Ease of UseProtective shroud allows for use of product in open-fixtures.
Highly efficientUp to 75 lumens per watt- 10-20% more efficient than standard metal halide.
Up to 16,000 hour life
Fits standard metal halide socketsNo new wiring or fixtures need.
GE imagination at work
ConstantColor® CMH® 70 Watt Open-Rated Elliptical Lamps Coated 70-Watt 3K
M98CMH70/C/U/MED/830/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.853003900
16000>80 3000K
3 Max15 Max
.438
.397
31070Clear 70-Watt 4K
M98CMH70/U/MED/942/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.852003700
16000>90 4200K
3 Max15 Max
.372
.372
31073Coated 70-Watt 4K
M98CMH70/C/U/MED/942/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.846003600
16000>90 4200K
3 Max15 Max
.372
.372
31074Clear 70-Watt 3K
M98CMH70/U/MED/830/O
UniversalED17
Heat Resistant Glass54 (2 1/8")
Medium Screw86 (3 3/8")
138 (5 7/16")7 (9/32")
4001903°3°
Open or Enclosed Fixture
70901.2.9
1.858004000
16000>80 3000K
3 Max15 Max
.438
.397
31069Product Information*
Product CodeRefer to ANSI CodeDescriptionPhysical CharacteristicsBurn PositionBulb DesignationBulb MaterialBulb Nominal Diameter, mm (inches)Base TypeLight Center Length, mm (inches)Max. Overall Length, mm (inches)Effective Arc Length, mm (inches)Max. Bulb Temp ° CMax Base Temp ° CEccentricity: Base-to-BulbEccentricity: Base-to-Arc AxisLuminaire CharacteristicsElectrical/Photometric CharacteristicsNominal Lamp WattsNominal Lamp VoltsNominal Lamp Amps-StartingNominal Lamp Amps-OperatingMax. Current Crest FactorInitial LumensMean Lumens (40% Rated Life)Average Rated Life (Hrs.) 10 Hrs./StartColor Rendering Index (Ra) CRI@KWarm-up time (Minutes) to 90%Hot Restart Time (Minutes) to 90%Chromaticity Coordinates: XChromaticity Coordinates: Y*All data are engineering estimates
WARNING - These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured and the arc tube continues to operate. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain types of lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available from the General Electric Company. If the outer envelope breaks or is punctured and the lamp continues to operate, immediately turn power off and remove lamp after it has cooled. These lamps are certified to comply with FDA radiation performance standards, 21 CFR Subchapter J.
Spectral Power Distribution - 3000K Lamp
Wavelength ( nm )
0
20
40
60
80
100
Rela
tive
Inte
nsity
400 500 600 700 800450 550 650 750
Spectral Power Distribution - 4200K Lamp
Wavelength ( nm )
0
20
40
60
80
100
Rela
tive
Inte
nsity
400 500 600 700 800450 550 650 750
Lamp Mortality Lumen Maintenance100 100
90 90
% L
umen
s
% S
urvi
ving 80 80
70 70
60 60
50 50
Operating Hours (Percent of Rated Life)0 20 40 60 80 100
Operating Hours (Percent of Rated Life)0 20 40 60 80 100
For additional product and application information, please consult GE’s Website: www.gelighting.com28328-2004 Printed in USA
Louis Poulsen Lighting, Inc., 3260 Meridian Parkway, Fort Lauderdale, FL 33331 Telephone: (954) 349-2525 Fax: (954) 349-2550
Ty p e :
P r o j e c t :
C a t a l o g N u m b e r :
CampbellD e s i g n : L o u i s e C a m p b e l l
incandescent
www.louispoulsen.com
STAINLESS STEEL AIRCRAFT SUSPENSION CABLE;
12' LG.
STAGGERED STRIPES AID IN EMANATING
DIFFUSE LIGHT
14.6"
10.8"
INNER SHADE IN HANDBLOWN CLEAR GLASS
WITH SANDBLASTED STRIPES
OUTER SHADE IN HANDBLOWN CLEAR GLASS
WTIH SANDBLASTED STRIPES
MEDIUM BASE SOCKET
5.3" DIA.
1.0"
4" OCTAGONAL JUNCTION BOX
(BY OTHERS)
WHITE CEILING CANOPY
CEILING LINE
WHITE PVC COVERED POWER CORD
3-CONDUCTOR; 18 AWG; 12' LG.
MAXIMUM LAMP:
1/75W/R20
(BY OTHERS)
Campbellpendants
Louis Poulsen Lighting, Inc., 3260 Meridian Parkway, Fort Lauderdale, FL 33331 Telephone: (954) 349-2525 Fax: (954) 349-2550
incandescent
www.louispoulsen.com
Design
Louise Campbell
Concept
Campbell pendant creates direct and diffuse illumination. The design is inspired by light refraction in nature.
The pendant consists of two separate layers of glass. Light passes through two separate glass shades, and
glare. The staggered sandblasted stripes aid in emanating diffuse light.
Finish
Clear glass with sandblasted stripes.
Material
Inner shade: Handblown clear glass with sandblasted stripes. Outer shade: Handblown clear glass with
sandblasted stripes.
Mounting
Suspension type: 1x stainless steel aircraft cable. Suspension length: Canopy: White. Cord type: 3-con-
ductor, 18 AWG white PVC power cord. Cor
Weight
Max. 17 lbs.
Label
cUL, Dry location. IBEW.
Product code Light source Voltage Finish
CAM 1/75W/R20 medium 120V STRIPED GLASS
Info notes:
313.34
311.34304.88
243.57
102.64
61.1543.4
27.53
24.06
23.69
13.144.58
220.94
307.26431.32
553.11
64
86.77109.66
123.72
676.82
30.3
42.159.1
75.8
8.8
11.915
16.9
92.7
32.6
45.463.7
81.7
9.5
12.812.8
18.3
100
10697
89
81
7570
65
61
57
5350
10692
81
72
6559
54
49
45
4239
10688
75
65
5751
46
42
38
3532
10684
70
60
5246
41
37
33
3028
10292
85
78
7267
62
58
55
5148
10288
78
70
6357
52
48
44
4138
10285
73
63
5650
45
41
37
3432
10282
68
58
5044
40
36
33
3027
9481
72
64
5853
49
45
41
3936
9478
68
59
5247
43
39
36
3330
9476
64
55
4843
38
34
31
2927
8675
67
60
5449
45
42
39
3634
8673
63
55
4944
40
37
34
3129
8671
60
52
4641
36
33
30
2826
7969
61
55
5046
43
40
37
34
32
7967
59
52
4642
38
35
32
30
28
7966
56
49
4339
35
32
29
2725
7663
53
46
4136
33
30
27
2523
78
157
235
313
1
2
92.7 %730
1/75W/R20 medium
1/75W/R20 medium
CAM 1/75W/R20 MEDIUM. IES
CAM 1/75W/R20 MEDIUM. IESL5634
DuraMax 75W Med120V R20 FR TP 1CTProduct family descriptionDuraMax reflector incandescent flood lightbulbs.
Features/Benefits• Lasts 1.5 years.• Wide beam of light is perfect for kitchens and family rooms.
Applications• Ideal for recessed, track and downlights.
Notes• Rated average life is the length of operation (in hours) at which point an average of 50% of the lamps will still be
operational and 50% will not.
Product dataProduct Number 167635Full product name DuraMax 75W Med 120V R20 FR TP 1CTOrdering Code 75R20/LL 120V TPPack type 1 Lamp in a Folding CartonPieces per Sku 1Skus/Case 12Pack UPC 046677167639EAN2USCase Bar Code 50046677167634Successor Product numberBase Medium [Single Contact Medium Screw]Base Information Aluminum [Aluminum Base]Bulb R-20Bulb Finish FrostedFilament Shape CC6 [Straight]Operating Position Universal [Any or Universal (U)]Packing Type 1CT [1 Lamp in a Folding Carton]Packing Configuration 12
1
9/4/2007
Product dataAtmosphere GasRated Avg. Life 2500 hrOrdering Code 75R20/LL 120V TPPack UPC 046677167639Case Bar Code 50046677167634Watts 75WVoltage 120VInitial Lumens 570 LmMax Overall Length (MOL) - C 3.94 inSpecial packing TP [Tray Pack]Product Number 167635
DuraMax R20 FR
Base Medium
2
9/4/2007
DuraMax R20 Operating Position Universal
3
9/4/2007
FeaturesTriples-H 226/7 is an efficient 7” aperture low brightness downlight, for
use with two 26-watt, 4-pin, triple tube compact fluorescent lamps by GE,
Sylvania or Philips. Triples-H 226/7 provides shielding angles of 40° parallel
to and 40° perpendicular to the lamps. Recess depth is only 7 ¼”.
One housing allows interchangeable use of downlight and wallwash reflec-
tors, permitting housings to be installed first and reflectors to be installed
or changed at any time.
Triples-H 226/7 uses two 26-watt, 4-pin, triple tube lamps providing 3600
lumens (more than a 150-watt incandescent), a 10,000-hour life, a color
rendering index (CRI) of 82, and color temperatures as warm as 2700°K
(nearly duplicating the color qualities of incandescent).
Reflectors are available in clear, natural aluminum in three finishes: Even-
Tone, our standard clear finish, partially diffuse, anti-iridescent and gently
luminous in appearance; OptiTone, specular and anti-iridescent, with
minimum brightness and maximum efficiency; and EasyTone, diffuse and
luminous. Additionally, reflectors are available in champagne gold, wheat,
pewter, and bronze. Wallwash (120°) and double wallwash (2x120°)
reflectors are also available.
Triples-H 226/7 includes a pair of mounting bars (¾” x 27” C channel).
Specialty bars for wood joist and T-bar installations are available as
accessories.
aPPLICatIONsFixture is recommended for downlighting or wallwashing in offices, stores,
banks, schools, auditoriums, hospitals and airports, as well as lobbies and
public areas. The shallow recess depth allows mounting in constricted
plenum situations.
Fixture is listed for Damp Location (may
not be suitable for some outdoor environments).
Fixture is in compliance with the
component based effi-
ciency standards of the
1995 New York State
Energy Conservation
Code. Fixture is prewired
with high power factor Class P
electronic ballast, suitable for use in a fire rated ceiling and approved for
eight #12 wire 75°C branch circuit pull-through wiring. Removal of the
reflector allows access to the ballast and junction box.
TRIPLES-H 226/7r e c e s s e d c o m p a c t f l u o r e s c e n t d o w n l i g h t / w a l l w a s h e r
Requires ceiling opening of 7 15/16” (202mm)
COMPACT FLUORESCENT
1-378
©Copyright, Edison Price Lighting 2006 11-0641-50 22ND STREET, L IC NY 11101 tel 718.685.0700 fax 718.786.8530 www.epl.com
PrODuCt CODeFor complete product code, list basic unit and select one item from each following box.
Basic Unit ................................................................ TRPH 226/7
Reflector Type Downlight ....................................................................no suffix Wallwash ......................................................................... WW Double Wallwash ............................................................ DWW
Voltage 120 volt service ............. 120 277 volt service ................ 277
Reflector and Flange Color Overlap FlushEvenTone Clear ........................... VOL ..................................VFLOptiTone Clear ...........................COL ................................. CFLEasyTone Clear .......................... ECOL ...............................ECFLChampagne Gold .......................GOL .................................GFLWheat ..................................... WHOL ............................WHFLPewter ....................................... POL .................................. PFLBronze ....................................... ZOL ..................................ZFLOther reflector finishes are available on special order.
Standard reflector flange continues reflector finish. White painted flanges and custom painted flanges are available on special order. Add WF (white flange) or CCF (custom color flange).
OPtIONsSpecify by adding to the basic unit.Dimmable 3-wire ballast; not for outdoor application ...............– DMEmergency battery pack operates one lamp in eventof power outage. Fixture footprint increases to 10 x 17 ¾” (254 x 451mm). Additional 1” (25mm) is required to remove EM pack through aperture. Not for outdoor application or double wallwasher (DWW) ....... – EM1/8” (3mm) thick clear acrylic shield, spring-mountedwithin reflector ..................................................................... – PS
For combinations of the Options above, contact factory or Edison Price Lighting representative. A modified fixture suitable for 2” maximum ceiling thickness is available on special order. Contact factory. A modified fixture suitable for 347-volt service is available on special order. Contact factory. An install-from-below version of this fixture, suitable for installation outside North America, is also available. Contact factory. Decorative reflector rings are available on special order. Contact factory.
TRIPLes-h 226/7
COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHODEffective Floor Cavity Reflectance 20%
Ceiling Reflectance (%) 80 70 50 30 10 0
Wall Reflectance (%) 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio
0 60 60 60 60 59 59 59 59 56 56 56 54 54 54 51 51 51 50 1 57 55 54 53 56 54 53 52 52 51 50 50 49 49 48 48 47 46 2 53 51 48 46 52 50 48 46 48 46 45 46 45 44 45 44 43 42 3 50 46 43 41 49 46 43 41 44 42 40 43 41 39 42 40 39 38 4 47 42 39 37 46 42 39 36 41 38 36 40 37 36 39 37 35 34 5 44 39 35 33 43 38 35 33 37 35 32 37 34 32 36 34 32 31 6 41 36 32 30 40 35 32 30 35 32 29 34 31 29 33 31 29 28 7 38 33 29 27 38 33 29 27 32 29 27 31 29 27 31 28 26 26 8 36 30 27 25 35 30 27 24 30 27 24 29 26 24 28 26 24 23 9 34 28 25 22 33 28 25 22 27 24 22 27 24 22 26 24 22 21 10 32 26 23 21 31 26 23 21 26 23 20 25 22 20 25 22 20 20
TRIPLes-h 226/7 WW
Vertical Average Average Average Angle 0° Longitude 90° Longitude 180° Longitude
45 20880 31650 35057 55 406 542 542 65 184 184 184 75 0 0 0 85 0 0 0
LUMINANCE DATA (Candela/m2)
To convert cd/m2 to footlamberts, multiply by 0.2919.
WALLWASH INFORMATION 3’ From Wall; 3’ O.C. 3’6” From Wall; 3’6” O.C.
Below Between Below Between Fixture Fixtures Fixture Fixtures
1 8 6 4 4 2 14 12 9 8 3 21 18 13 10 4 24 23 17 16 5 22 22 18 17 6 19 18 16 16 7 15 15 14 14 8 13 12 12 11 9 10 10 10 10 10 8 8 8 8 11 7 7 7 7 12 5 5 6 6
All vertical footcandles are initial values with no contribution from ceiling or floor reflectances. Computation performed with at least five wallwashers.
ZONAL LUMEN SUMMARY
Zone Lumens % Lamp % Fixture 0 - 30° 847 23.5 46.7 0 - 40° 1384 38.5 76.3 0 - 60° 1813 50.4 99.9 0 - 90° 1815 50.4 100.0 90 - 180° 0 0.0 0.0 0 - 180° 1815 50.4 100.0
DistanceFrom
Ceiling(Feet)
CANDLEPOWER DISTRIBUTION (Candela) 0.0 45.0 90.0 135.0 180.0
0 957 957 957 957 957 5 914 947 1006 1016 998 15 780 928 1130 1150 1048 25 768 868 1053 1143 1112 35 570 771 925 1005 936 45 380 477 576 641 638 55 6 7 8 9 8 65 2 2 2 2 2 75 0 0 0 0 0 85 0 0 0 0 0 90 0 0 0 0 0
Vertical Angle
Horizontal Angle
PHOTOMETRIC REPORT
Luminaire ............ recessed compact fluorescent downlight with spun aluminum reflectorLamp .................. two Philips 26-watt triple-tube compact fluorescent, 4-pin, GX24q-3 base, 1800 lumens each Efficiency ............ 50.4%Spacing Criteria .... 0°- 1.1, 90°-1.5, 180°-1.5Axis orientation.... 0° plane is parallel to lamps, opposite sockets
ReportNo.50243.OriginalIndependentTestingLaboratories,Inc.(ITL)testreportfurnisheduponrequest.
BALLAST INFORMATION Voltage 120 277 Input Watts 56 56 Line Current (A) .49 .21 Power Factor (%) >98 >98 THD (%) <10 <10 Min. Starting Temp* (°F) 0 0
*Consult lamp manufacturers for specific temperatures.
Revised 09/02/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
ICF-2S26-H1-LD@277Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamps
Rated
Lamp Watts
Min. Start
Temp (°F/C)
Input
Current
(Amps)
Input
Power
(ANSI Watts)
Ballast
Factor
MAX
THD
%
Power
Factor
MAX Lamp
Current
Crest Factor
B.E.F.
CFM26W/GX24Q 1 26 0/-18 0.11 29 1.10 10 0.98 1.5 3.79
* CFM26W/GX24q 2 26 0/-18 0.20 54 1.00 10 0.99 1.5 1.85
CFM32W/GX24q 1 32 0/-18 0.13 36 0.98 10 0.98 1.5 2.72
CFM42W/GX24q 1 42 0/-18 0.17 46 0.98 10 0.98 1.5 2.13
CFQ26W/G24q 1 26 0/-18 0.10 27 1.00 10 0.98 1.5 3.70
CFQ26W/G24q 2 26 0/-18 0.19 51 1.00 10 0.99 1.5 1.96
CFS21W/GR10q 2 21 0/-18 0.18 51 1.12 10 0.99 1.5 2.20
FT24W/2G11 2 24 0/-18 0.18 48 0.93 10 0.99 1.5 1.94
Wiring Diagram
WIRING: (2) LAMPS (1) LAMP
Green Terminal must be Grounded
GREEN
BLACK
WHITE BALLASTLINE
BLUE
RED
YELLOW
RED
BLUE
The wiring diagram that appears above is for
the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 0.0
White 0.0
Blue 0.0
Red 0.0
Yellow 0
Gray
Violet
in. cm.
Yellow/Blue
Blue/White
Brown
Orange
Orange/Black
Black/White
Red/White
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
4.98 " 2.4 " 1.0 " 4.6 "
4 49/50 2 2/5 1 4 3/5
12.6 cm 6.1 cm 2.5 cm 11.7 cm
ICF-2S26-H1-LD@277Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Notes:
Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements.
1.3 Ballast shall be provided with poke-in wire trap connectors color coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Programmed Start except for ballasts with -QS suffix, which shall be Rapid Start.
2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with
no damage to the IntelliVolt ballast. RCF models shall operate from 60 Hz input source of 120V with sustained variations of +/- 10% (voltage
and frequency) with no damage to the ballast.
2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared
devices and eliminate visible flicker.
2.5 Ballast shall have a Power Factor greater than 0.98 for primary lamp.
2.6 Ballast shall have a minimum ballast factor of 1.00 for primary lamp application.
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations.
2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.9 Ballast shall have a Class A sound rating.
2.10 Ballast shall have a minimum starting temperature of -18C (0F) for primary lamp. Ballasts for PL-H lamps shall have a minimum starting
temperature of -30C (-20F) for primary lamp.
2.11 Ballast shall provide Lamp EOL Protection Circuit.
2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall be Underwriters Laboratories (UL) rated for use in air-handling spaces.
3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.5 Ballast shall comply with ANSI C82.11 where applicable.
3.6 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated) except for RCF models which shall be Consumer (Class B).
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 75C and three-years for a maximum case temperature of 85C (90C 3year warranty for ICF1H120-M4-XX, ICF2S42-90C-M2-XX and ICF2S70-M4-XX modesls).
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
4.4 Ballast shall be Advance part # _____________ or approved equal.
Revised 09/02/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018TELEPHONE: (847) 390-5000 FAX: (847) 390-5109
PL-T 26W/830GX24q-3 /4P ALTO1CTProduct family descriptionPL-T Triple 4pin Fluorescent Lamp withAmalgam.
Features/Benefits• ALTO® Lamp Technology - Passes EPA's TCLP test for non-hazardous waste.• Utilizes amalgam technology to provide > 90% of rated lumens in ambient temperatures from 23F to 130F.• Triple tube design available in 18, 26, 32, and 42W.• Excellent Color Rendering - 82 Color Rendering Index (CRI).• Broad Range of Color Temperature - Available in 2700, 3000, 3500 and 4100K.• Dimmable - PL-T 4-pin lamps may be used with electronic dimming ballasts.• Long Life - 12,000 hours.• Energy Saving - Designed for use with electronic ballasts for lower operating costs and flicker-free starting.
Applications• Ideal for downlights and medium bay multi-lamp fixtures for general lighting.
Notes• Rated average life under specified test conditions with lamps turned off and restarted no more frequently than
once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. (202)• Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating
life, when the output is measured during operation on a reference ballast under standard laboratory conditions.(203)
• Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output isbased upon measurements obtained during lamp operation on a reference ballast under standard laboratoryconditions. (208)
Product dataProduct Number 268235Full product name PL-T 26W/830 GX24q-3 /4P ALTO 1CTOrdering Code PL-T 26W/830/4P/ALTOPack type 1 Lamp in a Folding CartonPieces per Sku 1Skus/Case 12Pack UPC 046677268237
1
9/4/2007
Product dataEAN2USCase Bar Code 50046677268232Successor Product numberBase GX24q-3Base Information 4PExecution /4P [4 Pins]Packing Type 1CT [1 Lamp in a Folding Carton]Packing Configuration 12Avg. Hrs. Life 12000 hrOrdering Code PL-T 26W/830/4P/ALTOPack UPC 046677268237Case Bar Code 50046677268232Watts 26WLamp Voltage 105 VDimmable YesColor Code 830 [CCT of 3000K]Color Rendering Index 82 Ra8Color Designation Warm WhiteColor Description 830 Warm WhiteColor Temperature 3000 KInitial Lumens 1800 LmInitial Lumens 1800 LmOverall Length C 126.4 mmDiameter D 39.85 mmDiameter D1 39.65 mmSpecial packing ALTOProduct Number 268235
PL-T 26WPL-T/830
PL-T/830
2
9/4/2007
PL-T
A B C D D1
Fullproduct name
Max Max Max Max Max
PL-T26W/830
GX24q-3 /4PALTO1CT
87 111.5 126.4 39.85 39.65
3
9/4/2007
(2) DIE FORMED ALUMINUM ANTI-GLARE RING WHITE OR NATURAL PAINTED ALUMINUM POWDER COATED FINISH
DIE CAST ALUMINUM SOCKETHOUSING AND BACK PLATEWITH WHITE OR NATURAL PAINTED ALUMINUM POWDERCOATED FINISH
DIE CAST ALUMINUM WIRING COMPARTMENT
(3) ALUMINUM CONNECTINGSTRUTS WITH WHITE OR NATURAL PAINTED ALUMINUM POWDER COATED FINISH
DIE CUT ALUMINUM REFLECTOR RINGWITH WHITE OR NATURAL PAINTED ALUMINUM POWDER COATED FINISH
ELECTRONIC BALLAST FOR120-277V OPERATION
LAMPHOLDER: (2) GX24q-3/4
(2) DIE CUT RUBBER GASKETS
MAXIMUM LAMP:2/26W/CF COMPACT FLUORESCENT(BY OTHERS)
(2) WHITE OPAL GLASS ENCLOSURES
4" OCTAGONAL JUNCTION BOX(BY OTHERS)
WALL SURFACE
WALLPROJECTION
12.7"
17.3"
22.1"
7.4"
17.2" DIA.
9.9"
7.1"
www.louispoulsen.com
Louis Poulsen Lighting, Inc., 3260 Meridian Parkway, Fort Lauderdale, FL 33331 Telephone: (954) 349-2525 Fax: (954) 349-255003-05
Ty p e :
P r o j e c t :
C a t a l o g N u m b e r :
Saturn Maxi WallD e s i g n : J o a c h i m L e p p e r
compact f luorescent
Saturn Maxi WallPhotometric Report: SAW-MAX-2-26W-GX24q-3/4.IES Report No.: L5518 Poulsen Report No.: SAW-MAX-2-26W-G X24q-3/4.IES Luminaire: Saturn Maxi Wall, White Lamp: 2/26W/GX24q-3/4 Efficiency: 51.2%
Description: All data shown are per 1800 lumens. This report can be used for calculation on all versions listed below. Use only actual lumen data when calculating.
Candlepower Distribution Zonal Lumen Summary
Vertical Angle Candela Zone Lumens % Lamp % Fixture 0 98.4 0-30 121.07 3.4 6.6 5 116.4 0-40 214.83 6 11.7 10 138.6 0-60 439.53 12.2 23.9 25 201.2 0-90 888.9 24.7 48.2 40 196.2 90-120 488.11 13.6 26.5 55 188.4 90-130 638.38 13.6 26.5 70 225.5 90-150 850.08 23.6 46.1 85 241.7 90-180 953.72 26.5 51.8 90 239 0-180 1842.63 51.2 100.0 120 268.3 150 178.2 180 28.3
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20%
Ceiling Reflectance (%) 80 70 50 30 10 0 Wall Reflectance (%) 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio
0 55 55 55 55 50 50 50 50 42 42 42 35 35 35 28 28 28 25 1 48 45 42 39 44 41 38 36 34 32 30 27 26 25 21 20 19 16 2 48 38 34 30 39 35 31 28 28 26 23 23 21 19 18 16 15 12 3 38 33 28 25 35 30 26 23 25 21 19 20 17 15 15 13 12 10 4 35 29 24 20 32 26 22 19 21 18 16 17 15 13 13 11 10 8 5 32 35 20 17 29 23 19 16 19 16 13 15 13 11 12 10 8 6 6 29 22 18 15 27 21 16 13 17 14 11 14 11 9 10 9 7 5 7 27 20 16 13 25 18 14 12 15 12 10 12 10 8 9 8 6 5 8 25 18 14 11 23 17 13 10 14 11 9 11 9 7 9 7 5 4 9 23 17 12 10 21 15 11 9 13 10 8 10 8 6 8 6 5 4 10 22 15 11 9 20 14 10 8 12 9 7 9 7 5 7 6 4 3
compact f luorescent
www.louispoulsen.com
Louis Poulsen Lighting, Inc., 3260 Meridian Parkway, Fort Lauderdale, FL 33331 Telephone: (954) 349-2525 Fax: (954) 349-2550
Saturn Maxi Wall provides general aswell as accent illumination. Bothanti-glare rings shield the lampsfrom view and the Saturn ringreflects the light into the space.Depending on the glass enclosure,the illumination is either soft or dis-tinct.
F i n i s hWhite or natural painted aluminum,powder coated.
M a t e r i a l Enclosure: Clear or white opal glass.Saturn ring: Die cut aluminum. Anti-glare ring: Die formed aluminum.Back plate: Die cast aluminum.
M o u n t i n gSurface: Mounted directly to finishedsurface over a recessed 4” octagonaljunction box.
W e i g h tMax. 20 lbs.
L a b e l cUL, Damp location. IBEW.
P r o d u c t c o d eSAW-MAX
L i g h t s o u r c e2/26W/CF Gx24q-3/4a,c
2/150W/A-21/CL mediumb,d
V o l t a g e120-277V120V
F i n i s hNAT. PAINT ALU.WHT
Specification notes: a. CF variant is provided with white opalglass enclosure.b. Incandescent variant is provided withclear glass enclosure.c. CF variant is provided with one 120-277V integral electronic ballast.d. Incandescent variant is only availablein 120V.
Info notes: I. The comparable EU version has the following classification: IngressProtection Code: IP44.
Spare parts:Orbiter/Saturn clear glassOrbiter/Saturn white opal glass
O r d e r i n g e x a m p l e :
1 2 3 4
Prod.code Light source Volt. Finish
SAW-MAX 2/26W/CF Gx24q-3/4 120-277V NAT. PAINT. ALU.
1
2
3
4
s p e c i f i c a t i o n
Revised 09/02/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
ICF-2S26-H1-LD@277Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamps
Rated
Lamp Watts
Min. Start
Temp (°F/C)
Input
Current
(Amps)
Input
Power
(ANSI Watts)
Ballast
Factor
MAX
THD
%
Power
Factor
MAX Lamp
Current
Crest Factor
B.E.F.
CFM26W/GX24Q 1 26 0/-18 0.11 29 1.10 10 0.98 1.5 3.79
* CFM26W/GX24q 2 26 0/-18 0.20 54 1.00 10 0.99 1.5 1.85
CFM32W/GX24q 1 32 0/-18 0.13 36 0.98 10 0.98 1.5 2.72
CFM42W/GX24q 1 42 0/-18 0.17 46 0.98 10 0.98 1.5 2.13
CFQ26W/G24q 1 26 0/-18 0.10 27 1.00 10 0.98 1.5 3.70
CFQ26W/G24q 2 26 0/-18 0.19 51 1.00 10 0.99 1.5 1.96
CFS21W/GR10q 2 21 0/-18 0.18 51 1.12 10 0.99 1.5 2.20
FT24W/2G11 2 24 0/-18 0.18 48 0.93 10 0.99 1.5 1.94
Wiring Diagram
WIRING: (2) LAMPS (1) LAMP
Green Terminal must be Grounded
GREEN
BLACK
WHITE BALLASTLINE
BLUE
RED
YELLOW
RED
BLUE
The wiring diagram that appears above is for
the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 0.0
White 0.0
Blue 0.0
Red 0.0
Yellow 0
Gray
Violet
in. cm.
Yellow/Blue
Blue/White
Brown
Orange
Orange/Black
Black/White
Red/White
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
4.98 " 2.4 " 1.0 " 4.6 "
4 49/50 2 2/5 1 4 3/5
12.6 cm 6.1 cm 2.5 cm 11.7 cm
ICF-2S26-H1-LD@277Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Notes:
Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements.
1.3 Ballast shall be provided with poke-in wire trap connectors color coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Programmed Start except for ballasts with -QS suffix, which shall be Rapid Start.
2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with
no damage to the IntelliVolt ballast. RCF models shall operate from 60 Hz input source of 120V with sustained variations of +/- 10% (voltage
and frequency) with no damage to the ballast.
2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared
devices and eliminate visible flicker.
2.5 Ballast shall have a Power Factor greater than 0.98 for primary lamp.
2.6 Ballast shall have a minimum ballast factor of 1.00 for primary lamp application.
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations.
2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.9 Ballast shall have a Class A sound rating.
2.10 Ballast shall have a minimum starting temperature of -18C (0F) for primary lamp. Ballasts for PL-H lamps shall have a minimum starting
temperature of -30C (-20F) for primary lamp.
2.11 Ballast shall provide Lamp EOL Protection Circuit.
2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall be Underwriters Laboratories (UL) rated for use in air-handling spaces.
3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.5 Ballast shall comply with ANSI C82.11 where applicable.
3.6 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated) except for RCF models which shall be Consumer (Class B).
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 75C and three-years for a maximum case temperature of 85C (90C 3year warranty for ICF1H120-M4-XX, ICF2S42-90C-M2-XX and ICF2S70-M4-XX modesls).
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
4.4 Ballast shall be Advance part # _____________ or approved equal.
Revised 09/02/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018TELEPHONE: (847) 390-5000 FAX: (847) 390-5109
PL-T 26W/830GX24q-3 /4P ALTO1CTProduct family descriptionPL-T Triple 4pin Fluorescent Lamp withAmalgam.
Features/Benefits• ALTO® Lamp Technology - Passes EPA's TCLP test for non-hazardous waste.• Utilizes amalgam technology to provide > 90% of rated lumens in ambient temperatures from 23F to 130F.• Triple tube design available in 18, 26, 32, and 42W.• Excellent Color Rendering - 82 Color Rendering Index (CRI).• Broad Range of Color Temperature - Available in 2700, 3000, 3500 and 4100K.• Dimmable - PL-T 4-pin lamps may be used with electronic dimming ballasts.• Long Life - 12,000 hours.• Energy Saving - Designed for use with electronic ballasts for lower operating costs and flicker-free starting.
Applications• Ideal for downlights and medium bay multi-lamp fixtures for general lighting.
Notes• Rated average life under specified test conditions with lamps turned off and restarted no more frequently than
once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. (202)• Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating
life, when the output is measured during operation on a reference ballast under standard laboratory conditions.(203)
• Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output isbased upon measurements obtained during lamp operation on a reference ballast under standard laboratoryconditions. (208)
Product dataProduct Number 268235Full product name PL-T 26W/830 GX24q-3 /4P ALTO 1CTOrdering Code PL-T 26W/830/4P/ALTOPack type 1 Lamp in a Folding CartonPieces per Sku 1Skus/Case 12Pack UPC 046677268237
1
9/4/2007
Product dataEAN2USCase Bar Code 50046677268232Successor Product numberBase GX24q-3Base Information 4PExecution /4P [4 Pins]Packing Type 1CT [1 Lamp in a Folding Carton]Packing Configuration 12Avg. Hrs. Life 12000 hrOrdering Code PL-T 26W/830/4P/ALTOPack UPC 046677268237Case Bar Code 50046677268232Watts 26WLamp Voltage 105 VDimmable YesColor Code 830 [CCT of 3000K]Color Rendering Index 82 Ra8Color Designation Warm WhiteColor Description 830 Warm WhiteColor Temperature 3000 KInitial Lumens 1800 LmInitial Lumens 1800 LmOverall Length C 126.4 mmDiameter D 39.85 mmDiameter D1 39.65 mmSpecial packing ALTOProduct Number 268235
PL-T 26WPL-T/830
PL-T/830
2
9/4/2007
PL-T
A B C D D1
Fullproduct name
Max Max Max Max Max
PL-T26W/830
GX24q-3 /4PALTO1CT
87 111.5 126.4 39.85 39.65
3
9/4/2007
hr20
hr29
hr35
hr41
lamps upsuspension length voltage options
4/26cFl2/27BX4/42cFl3/39BX
4/42cFl4/39BX6/39BX4/42cFl4/40BX6/40BX4/50BX6/50BX4/55BX6/55BX
Ceiling to top of fi xture in inches
Sgw-semi-gloss white(refer to color chart in Product Selection Guide for other standard colors) Sch-satin chromech-polished chromeBr-polished brassAB-antique brassSBn-satin brushed nickelPn-polished nickelcc-custom color
(trim fi nish includes trim, fi nial and straps)
120277347(40W only)
EXAMPlE
project name: ___________________________________ type: ____________________________________ quantity: ______________________
ordEr
hr35 6/39 So XX” Sgw 120 AlB/3–
trim: Trim ring is 20-gauge spun steel and attaches to luminous bowl with no visible hardware. luminous Bowl: Bowl is formed white opal acrylic standard with the option of three faux alabaster choices. Lamp housing has no open holes to minimize the collection of dust and debris in bowl. Dust cover is optional. New England style features a bell shaped bowl.refl ector: Biaxial fl uorescent refl ector is a combination of high refl ectance specular aluminum and high refl ectance white powder coat paint. CFL refl ector is high refl ectance white powder coat paint.optics: Maximum candlepower at 135 degrees or below to minimize brightness on ceiling above fi xture and maximize fi xture spacing. Recommended suspension is 24” or more.Suspension: 5/8” OD stem with 30 degree swivel at canopy for single pendant units and 1” stem for chandelier units. Stem and canopy fi nish to be specifi ed. Minimum suspension length for RDS option is 18”. Consult factory for non-swivel fl at ceiling applications. Electrical: Fluorescent ballasts are instant start, normal light output, high power factor, and sound rated A. Ballast factor varies between 0.86 and 0.90 depending on lamp wattage, number of lamps, and voltage. Consult factory for specifi c ballast factor. Finish: Standard colors are available from color chart. Plated fi nishes and custom colors are available. Specify fi nish of trim ring, and suspension with canopy. certifi cation: UL and CUL listed and IBEW labeled.
SPEciFicAtionS
lamps down
n/A
1/282d2/39BX3/39BX1/382d4/39BX
1/382d2/40BX4/40BX2/50BX4/50BX2/55BX4/55BX
1/382d A– – – – – – – –
diameter A B20” 20 3/4” 8 5/8” 527 21929” 28 5/8” 11” 727 27935” 34 5/8” 12 1/4” 879 31141” 40 5/8” 13 1/4” 1031 337note: consult factory for larger diameters.
diMEnSionAl dAtA tABlE
ht-Traditionalhc-Colonialhn-New England
So-stem onlyrdS-stem with fl uted rodscn-stem with chainsdBSo-double chandelier, stem onlytrSo-triple chandelier, stem onlyqdSo-quad chandelier, stem onlydBrdS-double chandelier, stem with fl uted rodstrrdS-triple chandelier, stem with fl uted rodsqdrdS-quad chandelier, stem with fl uted rodsdBcn-double chandelier, stem with chainstrcn-triple chandelier, stem with chainsqdcn-triple chandelier, stem with chainsdBSh-double hook chandeliertrSh-triple hook chandelierqdSh-quad hook chandelier
glr-GLR fuse and HLR holdergMF-GMF slow blow fuse and holderdc-Dust coverAlB/#-Faux alabaster bowl(see color chart for #)EM1-B70A or equalEM2-B50 or equalEM3-B100 or equalEM4-B60 or equaldiM1-Advance Mark VII dimmingdiM2-Advance Mark X dimmingdiM3-Lutron ECO-10 dimming ballastdiM4-Lutron Hi-Lume dimming ballastdiM5-Lutron ECO-10 TVE dimming ballast
B
A
fi xture series bowl style suspension style trim fi nish
Sgw-semi-gloss white(refer to color chart in Product Selection Guide for other standard colors) Sch-satin chromech-polished chromeBr-polished brassAB-antique brassSBn-satin brushed nickelPn-polished nickelcc-custom color
Sgwsuspension fi nish
– – – – – – – – –
heritage pendanth
erit
age
8 LaM Lighting • 2930 South Fairview Street • Santa ana • Ca 92704-6598 • phone: 714-549-9765 • Fax: 714-662-4515 • www.LaMLighting.CoM
Due to a program of continuous improvement, LAM Lighting reserves the right to make any variation in design or construction to the equipment described.
lAMP conFigUrAtionS
hr20-2 hr29-3 hr35-4 hr35-6 hr41-4 hr41-6 hr-CFL
chAndEliErS
C
B
A
B
A
B
A
specify
DE
ArM chAndEliEr diMEnSion dAtA
diameter A B c d E20” 20 3/4” 54” 49 1/2” 14 1/8” 15 5/8” 527 1372 1257 359 39729” 28 5/8” 75 1/2” 69 1/4” 16” 17 1/2” 727 1918 1759 406 44535” 34 5/8” 91 3/8” 83 13/16” 17 3/8” 18 7/8” 879 2321 2129 441 47941” 40 5/8” 107 1/4” 98 5/8” 18 3/4” 20 1/4” 1032 2724 2505 476 514
F
D
specify
StylES
traditional Colonial new england
heritage pendanth
eritage
LaM Lighting • 2930 South Fairview Street • Santa ana • Ca 92704-6598 • phone: 714-549-9765 • Fax: 714-662-4515 • www.LaMLighting.CoM 9
EMErgEncy PowEr diMMing Fixture Uplight Battery diameter lamps location limitations 20 4/26 Remote 3-feet maximum remote distance 20 2/27 Remote 3-feet maximum remote distance 29 4/42 Integral 2 circuit (2 ballasts) uplight maximum 29 3/39 Integral 1 circuit (1 ballast) uplight 35 4/42 Integral 2 circuit (2 ballasts) uplight maximum 35 6/39 Integral 2 circuit (2 ballasts) uplight maximum 35 4/40 Integral 2 circuit (2 ballasts) uplight maximum 41 4/42 Integral 2 circuit (2 ballasts) uplight maximum 41 4/40 Integral 2 circuit (2 ballasts) uplight maximum 41 4/50 Integral 2 circuit (2 ballasts) uplight maximum 41 4/55 Integral 2 circuit (2 ballasts) uplight maximum 41 6/40 Integral 2 circuit (2 ballasts) uplight maximum 41 6/50 NA Not Available 41 6/55 NA Not Available
Fixture Uplight diameter lamps diM1 diM2 diM3 diM4 diM5 20 4/26 Yes Yes No Yes No 20 2/27 No No No No No 29 4/42 Yes Yes No Yes No 29 3/39 Yes Yes Yes Yes No 35 4/42 Yes Yes No Yes No 35 6/39 Yes Yes Yes Yes No 35 4/40 No No Yes Yes No 41 4/42 Yes Yes No Yes No 41 4/40 Yes Yes Yes Yes Yes 41 4/50 No No Yes Yes No 41 4/55 Yes Yes No No No 41 6/40 Yes Yes Yes Yes Yes 41 6/50 No No Yes Yes No 41 6/55 Yes Yes No No No
hook chAndEliEr diMEnSion dAtAdiameter A B c d F20” 20 3/4” 50 13/16” 46 13/16” 8 9/16” 18 5/8” 527 1291 1189 217 47329” 28 5/8” 78 7/8” 72 1/8” 11” 22” 727 2003 1832 278 55935” 34 5/8” 84 7/8” 78 1/8” 12 1/4” 22” 879 2156 1984 311 55941” 40 5/8” 90 7/8” 84 1/8” 13 1/4” 22” 1032 2308 2139 337 559
Revised 09/02/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
ICF-2S42-M2-BS@277Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamps
Rated
Lamp Watts
Min. Start
Temp (°F/C)
Input
Current
(Amps)
Input
Power
(ANSI Watts)
Ballast
Factor
MAX
THD
%
Power
Factor
MAX Lamp
Current
Crest Factor
B.E.F.
* CFM42W/GX24q 2 42 0/-18 0.33 93 0.97 10 0.99 1.5 1.04
Wiring Diagram
WIRING: (2) LAMPS (1) LAMP
Green Terminal must be Grounded
GREEN
BLACK
WHITEBALLASTLINE
BLUE
RED
YELLOW
RED
BLUE
The wiring diagram that appears above is for
the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 0.0
White 0.0
Blue 0.0
Red 0.0
Yellow 0
Gray
Violet
in. cm.
Yellow/Blue
Blue/White
Brown
Orange
Orange/Black
Black/White
Red/White
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
4.98 " 3.00 " 1.29 " 2.00 "
4 49/50 3 1 29/100 2
12.6 cm 7.6 cm 3.3 cm 5.1 cm
ICF-2S42-M2-BS@277Brand Name SMARTMATE
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Notes:
Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements.
1.3 Ballast shall be provided with poke-in wire trap connectors color coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Programmed Start except for ballasts with -QS suffix, which shall be Rapid Start.
2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with
no damage to the IntelliVolt ballast. RCF models shall operate from 60 Hz input source of 120V with sustained variations of +/- 10% (voltage
and frequency) with no damage to the ballast.
2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared
devices and eliminate visible flicker.
2.5 Ballast shall have a Power Factor greater than 0.98 for primary lamp.
2.6 Ballast shall have a minimum ballast factor of 1.00 for primary lamp application.
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations.
2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.9 Ballast shall have a Class A sound rating.
2.10 Ballast shall have a minimum starting temperature of -18C (0F) for primary lamp. Ballasts for PL-H lamps shall have a minimum starting
temperature of -30C (-20F) for primary lamp.
2.11 Ballast shall provide Lamp EOL Protection Circuit.
2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall be Underwriters Laboratories (UL) rated for use in air-handling spaces.
3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.5 Ballast shall comply with ANSI C82.11 where applicable.
3.6 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated) except for RCF models which shall be Consumer (Class B).
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 75C and three-years for a maximum case temperature of 85C (90C 3year warranty for ICF1H120-M4-XX, ICF2S42-90C-M2-XX and ICF2S70-M4-XX modesls).
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
4.4 Ballast shall be Advance part # _____________ or approved equal.
Revised 09/02/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018TELEPHONE: (847) 390-5000 FAX: (847) 390-5109
PL-T 42W/830GX24q-4 /4P ALTO1CTProduct family descriptionPL-T Triple 4pin Fluorescent Lamp withAmalgam.
Features/Benefits• ALTO® Lamp Technology - Passes EPA's TCLP test for non-hazardous waste.• Utilizes amalgam technology to provide > 90% of rated lumens in ambient temperatures from 23F to 130F.• Triple tube design available in 18, 26, 32, and 42W.• Excellent Color Rendering - 82 Color Rendering Index (CRI).• Broad Range of Color Temperature - Available in 2700, 3000, 3500 and 4100K.• Dimmable - PL-T 4-pin lamps may be used with electronic dimming ballasts.• Long Life - 12,000 hours.• Energy Saving - Designed for use with electronic ballasts for lower operating costs and flicker-free starting.
Applications• Ideal for downlights and medium bay multi-lamp fixtures for general lighting.
Notes• Rated average life under specified test conditions with lamps turned off and restarted no more frequently than
once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. (202)• Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating
life, when the output is measured during operation on a reference ballast under standard laboratory conditions.(203)
• Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output isbased upon measurements obtained during lamp operation on a reference ballast under standard laboratoryconditions. (208)
Product dataProduct Number 268730Full product name PL-T 42W/830 GX24q-4 /4P ALTO 1CTOrdering Code PL-T 42W/830/4P/ALTOPack type 1 Lamp in a Folding CartonPieces per Sku 1Skus/Case 12Pack UPC 046677268732
1
10/4/2007
Product dataEAN2USCase Bar Code 50046677268737Successor Product numberBase GX24q-4Base Information 4PExecution /4P [4 Pins]Packing Type 1CT [1 Lamp in a Folding Carton]Packing Configuration 12Avg. Hrs. Life 12000 hrOrdering Code PL-T 42W/830/4P/ALTOPack UPC 046677268732Case Bar Code 50046677268737Watts 42WLamp Voltage - VDimmable YesColor Code 830 [CCT of 3000K]Color Rendering Index 82 Ra8Color Designation Warm WhiteColor Description 830 Warm WhiteColor Temperature 3000 KInitial Lumens - LmInitial Lumens 3200 LmOverall Length C 158.4 mmDiameter D 39.85 mmDiameter D1 39.65 mmSpecial packing ALTOProduct Number 268730
PL-T 42WPL-T/830
PL-T/830
2
10/4/2007
PL-T
A B C D D1
Fullproduct name
Max Max Max Max Max
PL-T42W/830
GX24q-4 /4PALTO1CT
119 143.5 158.4 39.85 39.65
3
10/4/2007
Questions to Ask
litecontrol.com
Type:Project:
litecontrol.com
Cove-30™
CC-AI-3000Concealed Cove System
CC-AI-3024T8-CWM-TW-ELB-2CWQ-EF-120 is a typical catalog number for a 2-lamp (2 lamps in cross-section), 4-foot long T8 fixture, Matte White finish, tandem-wired electronic ballast, pre-wired with two-circuit branch wiring, emergency fluorescent ballast, 120 volts.
Specifications
Ordering guide
Cross-section lamping
HOUSING. Die-formed steel. Paint finish is baked white enamel. Ends provided with a 7/8" hole to accommodate pre-wiring.REFLECTORS. Die-formed steel, finished in high-reflectance white, precisely shaped for maximum horizontal light projection. Configuration with four reflector surfaces includes a high-reflectance specular aluminum insert. Luminance Control Deflector™ (LCD), finished in high-reflectance white, reduces wall brightness directly above fixture and minimizes socket shadows between fixtures.LAMPING. Available in one- and two-lamp T5, T5HO or T8; one-lamp 39-, 40-, or 50-watt twin-tube compact fluorescent cross-sections . BALLAST. Electronic Ballast (ELB - for T8 lamping) or Low-profile Electronic Ballast (LP/ELB - for T5 or T5HO lamping), high power factor, thermally protected Class P, Sound Rated A, manufactured by a UL Listed manufacturer, as available, determined by Litecontrol. Ballasts with a voltage range of 120 to 277 will be used when fixture configuration and ballast availability allow. The minimum number of ballasts will be used.TANDEM WIRING. When selected from Ordering guide below, fixtures wired to switch in-line lamps separately, providing two (two-lamp cross-section fixtures only) levels of light.PRE-WIRING. Fixtures are supplied with #12 AWG type THHN wire for branch circuits. One end will have factory-installed push-in quick-connects. The other end will be stripped back 1/2" for quick connection in field. For fixtures to accommodate special circuits such as night light and emergency, etc., in-field wiring will be required. See Pre-wiring Information for details.MOUNTING. Fixtures are installed in cove provided by others. See Planning for installation for detailed information.CERTIFICATION. Fixture and electrical components shall be UL and/or CUL Listed and shall bear the I.B.E.W., A.F. of L. label. Note: Litecontrol reserves the right to change specifications without notice for product development and improvement.
1-T8 1-BX39, 40 or 50
2-T5 or T5HO
2-T8
1. 120 or 277 volt? 2. Row information, including desired fixture lengths?
3. Other options?
A Luminance Control Deflector™ minimizes socket shadows.
B High-reflectance aluminum for maximum horizontal light projection.
C High-reflectance white reflector for efficient indirect distribution.
3 1/8"(79)
8"(203)
Product, lamping, & length
CC - AI - 30 2 4 T8 -
Mounting
CC ConcealedCove
Distribution
AI Asymmetricindirect
Series
30
Lamp Count
1,* 2 1,* 2 1,* 2 2, 4 2, 4 1 2 4 2 4
seenotes
Nominal Length(ft)
2 3 4 6 8 2 4 8 3 6
Lamp Type
T8T5HOT5
BX40BX50
BX39
Options
CWM - TW - ELB - 2CWQ - LP/EF - 120
Finish
CWM(Matte White) is standard
TandemWiring
-- TW
see notes
Ballast options
ELB is std. for T8 or BXLP/ELB is std. for T5 or T5HO
DA/ELBHEL/ELBECO/ELB
see Ballast options
Pre-wiring
1CWQ2CWQ
Other options
LP/EFFWKC/WPWKC/NPAMA5AMA10
see Other options
Volts
120 277
notes: Lamp Count = total number of lamps in the fixture* For applications using 1-lamp T5 or T5HO see Cove-25.Tandem Wiring not available for one-lamp cross-section fixturesFor Ordering guide information in shaded areas, choose selection by reading ACROSS the shaded areas for correct specifications.
litecontrol.com
Click on Quick Find
litecontrol.com
litecontrol.com
. . . an employee owned company100 Hawks Avenue Hanson MA 02341 781 294 0100 FAX 781 293 2849 [email protected] litecontrol.com
90˚
120˚
150˚180˚
0˚60˚
30˚
Across45Along
For maximum illumination level flexibility, five lamp combinations are available. For a one-lamp T5 or T5HO fixture in a 2 1/16" deep x 6" wide housing refer to Cove-25 (CC-AI-2500).
As the distance from fixture to ceiling is increased, light distribution becomes more uniform. To avoid excessive brightness on ceiling, maximize the distance from the fixture to the ceiling. A fixture with less output ( i.e., one-lamp T8) may be tolerated closer to ceiling than one with higher output. To best evaluate an acceptable mounting position, a mock-up is recommended.
Position fixtures along walls as desired to satisfy visual design goals. To avoid excess corner brightness,stop fixtures 9-15" short of end walls; 0-6" from outside corner.
If using high-output T5 lamps, be advised that lamp lumens per foot for each of the lamp lengths are different. Caution is advised when mixing fixture lengths in rows.
For even lower beam throw and better distribution, consider the Adjustable Mounting Angle (AMA) option. This lowers the beam throw by 5° or 10°. Size the cove to hide lamps and fixture. This should only be considered if viewing angles prevent a direct view of the raised portion of the fixture, or if a cut-off angle below horizontal is deemed acceptable.
If the zonal cavity method is used to calculate an average illumination, it is advised in a perimeter layout to derate the illuminance by 10%.
If uniformity of light levels is desired,room width should not exceed the following:Fixtures along one wall: 6xDFixtures on opposite walls: 12xD
* Recommended minimum interior cove height
Planning for installation
Photometric data
Design guidelines
Ballast options
Specify in place of ELB or LP/ELB, contact factory for availability/compatibility with lamping:DA/ELB Advance Mark VII Dimming Ballast.HEL/ELB Osram Sylvania Helios Dimming Ballast.ECO/ELB Lutron ECO-10 Dimming Ballast.
LP/EF Low-profile Emergency Fluorescent Ballast. Battery-powered ballast from a UL Listed manufacturer will operate one T5 or T5HO lamp for 1 1/2 hours.F Fuse. Slow or fast blow, determined by Litecontrol.WKC/WP Corner Wiring Kit. With quick-connects.WKC/NP Corner Wiring Kit. Without quick-connects.AMA Adjustable Mounting Angle. Quick attach component to tilt housing either 5° or 10°.
Other options
8 1/4" *(210)
8"(203)
3 1/8"(79)
3 1/4" *(83)
CW
FW
FD CD
5° or 10°
����������
�������
�����
�
Cove provided by others. Interior cove dimensions should allow for 3 1/8" x 8" fixture cross-section to fit within cove, taking into consideration as-built tolerances. For maximum efficiency, wall and ceiling above cove should have matte surfaces with high reflectances. See design guidelines below. Maximum fixture weight per foot is four pounds.Corner Wiring KitProvides the advantages of pre-wiring around corners. Make connections at each end of the flexible whip, push wires into fixtures, then snap onto headers. Specify WKC/WP (with push-in quick-connects).Adjustable Mounting Angle (AMA) OptionWhen room geometry allows, fixture may be tilted, thereby lowering the beam and resulting in a more effective distribution of light into the room. AMA (Adjustable Mounting Angle) quick attach component snaps onto housing to raise back of fixture 5° or 10°. Recommended cove sizes are shown.
Angle of Tilt
Ordering Option
Fixture Depth (FD)
Fixture Width (FW)
Recommended Cove Depth (CD)
Recommended Cove Width (CW)
0 (standard) 3 1/8" 8" 3 1/4" 8 1/4"
5° AMA 3 3/4" 8 1/4" 3 1/4" 8 5/8"
10° AMA 4 1/4" 8 3/8" 3 1/4" 8 5/8"
90˚
120˚
150˚180˚
0˚60˚
30˚
Across45Along
A. CC-AI-3014T8-LP/ELB 79.5% Efficiency Litecontrol Certified Test Report #29611000
B. CC-AI-3024T8-LP/ELB 63.2% Efficiency Litecontrol Certified Test Report #29521000
For complete photometric information, see website.
A. B.
30
Single row end clearance
Inside corner positioning
Outside corner positioning
9-15" 0-6"9-15"
9-15" 0-6"9-15"
9-15" 0-6"9-15"
600
1200
1000
2000
. . . an employee owned company100 HAWKS AVENUE HANSON MA 02341 781 294 0100 FAX 781 293 2849 [email protected] www.litecontrol.com
90˚
120˚
150˚180˚
0˚60˚
30˚
Across45Along
PHOTOMETRIC DATA
CC-AI-3024T5HO-LP/ELB 81.0 % EfficiencyLitecontrol Certified Test Report #29626000
RCC 80 70 50 30 10 0
RCR
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Floor Cavity Reflectance .20
0 .77 .77 .77 .77 .66 .66 .66 .66 .45 .45 .45 .26 .26 .26 .08 .08 .08 .001 .70 .67 .64 .61 .60 .57 .55 .52 .39 .38 .37 .23 .22 .21 .07 .07 .07 .002 .64 .58 .54 .50 .54 .50 .46 .43 .34 .32 .30 .20 .19 .18 .06 .06 .06 .003 .58 .51 .46 .42 .49 .44 .40 .36 .30 .27 .25 .17 .16 .15 .06 .05 .05 .004 .53 .45 .39 .35 .45 .39 .34 .30 .27 .24 .21 .15 .14 .13 .05 .05 .04 .005 .48 .39 .34 .29 .41 .34 .29 .26 .24 .20 .18 .14 .12 .11 .04 .04 .04 .006 .44 .35 .29 .25 .38 .30 .26 .22 .21 .18 .16 .12 .11 .09 .04 .03 .03 .007 .41 .32 .26 .22 .35 .27 .22 .19 .19 .16 .13 .11 .09 .08 .04 .03 .03 .008 .38 .29 .23 .19 .32 .24 .20 .16 .17 .14 .12 .10 .08 .07 .03 .03 .02 .009 .35 .26 .20 .16 .30 .22 .17 .14 .15 .12 .10 .09 .07 .06 .03 .02 .02 .00
10 .32 .23 .18 .14 .28 .20 .16 .13 .14 .11 .09 .08 .06 .05 .03 .02 .02 .00
ZONAL LUMEN SUMMARY% %
ZONE LUMENS LAMP LUMINAIRE
180-90° 8099 81.00 100.0090-0° 0 .00 .00180-0° 8099 81.00 100.00
0° PLANE PERPENDICULAR TO LAMPSCANDLEPOWER SUMMARY
180 1682 1682 1682 1682 1682175 1610 1616 1684 1781 1872 163170 1485 1545 1669 1909 2080165 1345 1435 1646 2048 2306 494160 1214 1315 1601 2185 2439155 1086 1210 1556 2247 2537 793150 954 1090 1496 2266 2770145 846 966 1422 2324 3055 1062140 733 847 1339 2454 3345135 624 744 1223 2623 3604 1302130 532 626 1135 2760 3762125 433 520 1025 2892 3636 1449120 365 425 907 2933 3671115 297 338 773 2818 3416 1422110 248 263 625 2559 2834105 192 190 465 2006 1886 998100 154 141 295 1195 129795 64 98 120 910 1013 42190 8 2 9 186 265
ANGLE 0 45 90 135 180 OUTPUTLUMENS
90˚
120˚
150˚180˚
0˚60˚
30˚
Across45Along
RCC 80 70 50 30 10 0
RCR
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Floor Cavity Reflectance .20
CC-AI-3014T5HO-LP/ELB 83.0 % EfficiencyLitecontrol Certified Test Report #29616000
0 .79 .79 .79 .79 .68 .68 .68 .68 .46 .46 .46 .26 .26 .26 .08 .08 .08 .001 .72 .69 .66 .63 .61 .59 .56 .53 .40 .39 .37 .23 .22 .22 .07 .07 .07 .00 2 .65 .60 .55 .51 .56 .51 .47 .44 .35 .33 .31 .20 .19 .18 .06 .06 .06 .003 .60 .52 .47 .43 .51 .45 .41 .37 .31 .28 .26 .18 .17 .15 .06 .05 .05 .004 .54 .46 .40 .36 .46 .40 .35 .31 .27 .24 .22 .16 .14 .13 .05 .05 .04 .005 .50 .40 .35 .30 .42 .35 .30 .26 .24 .21 .19 .14 .12 .11 .04 .04 .04 .006 .46 .36 .30 .26 .39 .31 .26 .23 .22 .18 .16 .13 .11 .09 .04 .03 .03 .007 .42 .32 .26 .22 .36 .28 .23 .19 .19 .16 .14 .11 .09 .08 .04 .03 .03 .008 .39 .29 .23 .19 .33 .25 .20 .17 .17 .14 .12 .10 .08 .07 .03 .03 .02 .009 .36 .26 .21 .17 .30 .23 .18 .15 .16 .13 .10 .09 .07 .06 .03 .02 .02 .00
10 .33 .24 .18 .15 .28 .21 .16 .13 .14 .11 .09 .08 .07 .05 .03 .02 .02 .00
ZONAL LUMEN SUMMARY% %
ZONE LUMENS LAMP LUMINAIRE
180-90° 4151 83.03 100.0090-0° 0 .00 .00180-0° 4151 83.03 100.00
CANDLEPOWER SUMMARY0° PLANE PERPENDICULAR TO LAMPS
180 950 950 950 950 950175 977 964 957 928 923 91170 991 976 949 903 890165 949 976 932 873 854 260160 851 933 910 830 820155 758 854 881 802 816 387150 671 768 847 751 898145 591 687 803 758 1001 485140 510 602 756 805 1164135 439 517 698 864 1365 579130 370 441 639 957 1563125 304 366 576 1091 1657 675120 256 301 506 1217 1922115 209 237 431 1308 2006 750110 169 183 350 1365 1913105 135 135 260 1246 1313 614100 105 97 164 815 102095 51 66 68 707 908 31590 3 3 10 149 212
ANGLE 0 45 90 135 180 OUTPUTLUMENS
1-T5HO
2-T5HO
. . . an employee owned company100 HAWKS AVENUE HANSON MA 02341 781 294 0100 FAX 781 293 2849 [email protected] www.litecontrol.com
PRE-WIRING INFORMATIONFixtures are supplied with #12 AWG type THHN wire for branch circuits. One end will have factory-installed push-in quick-connects. The other end will be stripped bacck 1/2’’ forquick connection in field. Each quick-connect joins two leads with each lead pushed into the device for a secure, positive connection.
Single-circuit option (1CWQ) will contain:(1) black lead wired to ballast(s) black lead for
connection to "HOT" feed.(1) white lead wired to ballast(s) white lead for
connection to "COMMON" feed.(1) green lead bonded to fixture for connection to "GROUND" feed.
Two-circuit option (2CWQ) will contain:(1) black lead wired to ballast(s) black lead for connection
to "HOT" feed of one switch leg of circuit.(1) red lead wired to ballast(s) black lead for connection
to "HOT" feed of other switch leg of circuit.(1) white lead wired to ballast(s) white lead for connection
to "COMMON" feed.(1) green lead bonded to fixture for connection to "GROUND" feed.
Pigtails for feed points or ends of rows are not furnished by Litecontrol. NOTE: All unused leads must be capped off.Rated ampacity of feed cords provided by Litecontrol (if applicable) shall be the limiting factor in the number of fixtures that can be fed from a single cord.These standard options do not provide for those installations where special circuits within the fixtures are involved, such as night/emergency, dimming controls, light level sensors, orMaster/Slave fixtures. The installing electrical contractor will furnish and install the branch circuit wiring for those fixtures required by the specific situation.
90˚
120
150˚180˚
0˚60
30˚
Across45Along
90˚
120˚
150˚180˚
0˚60˚
30˚
Across45Along
RCC 80 70 50 30 10 0
RCR
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Floor Cavity Reflectance .20
CC-AI-3024T8-LP/ELB 63.2 % EfficiencyLitecontrol Certified Test Report #29521000
0 .60 .60 .60 .60 .51 .51 .51 .51 .35 .35 .35 .20 .20 .20 .06 .06 .06 .00 1 .55 .52 .50 .48 .47 .45 .43 .41 .31 .30 .28 .18 .17 .17 .06 .05 .05 .00 2 .50 .45 .42 .39 .42 .39 .36 .33 .27 .25 .23 .15 .14 .14 .05 .05 .04 .00 3 .45 .40 .36 .32 .39 .34 .31 .28 .24 .21 .20 .14 .13 .12 .04 .04 .04 .00 4 .41 .35 .31 .27 .35 .30 .26 .24 .21 .18 .17 .12 .11 .10 .04 .04 .03 .00 5 .38 .30 .26 .23 .32 .27 .23 .20 .18 .16 .14 .11 .09 .08 .03 .03 .03 .00 6 .35 .28 .23 .20 .29 .24 .20 .17 .16 .14 .12 .10 .08 .07 .03 .03 .02 .00 7 .32 .25 .20 .17 .27 .21 .17 .15 .15 .12 .10 .09 .07 .06 .03 .02 .02 .00 8 .29 .22 .18 .15 .25 .19 .15 .13 .13 .11 .09 .08 .06 .05 .02 .02 .02 .00 9 .27 .20 .16 .13 .23 .17 .14 .11 .12 .10 .08 .07 .06 .05 .02 .02 .02 .00
10 .25 .18 .14 .11 .21 .16 .12 .10 .11 .09 .07 .06 .05 .04 .02 .02 .01 .00
ZONAL LUMEN SUMMARY% %
ZONE LUMENS LAMP LUMINAIRE
180-90° 3664 63.18 100.0090-0° 0 .00 .00180-0° 3664 63.18 100.00
CANDLEPOWER SUMMARY0° PLANE PERPENDICULAR TO LAMPS
180 776 776 776 776 776175 685 711 770 837 879 74170 599 648 766 896 970165 546 588 749 958 1068 220160 493 539 732 1009 1168155 445 491 709 1058 1252 360150 400 446 678 1099 1348145 353 403 642 1146 1424 483140 307 356 601 1182 1501135 270 310 554 1211 1549 579130 231 265 503 1226 1600125 191 224 451 1243 1577 633120 164 185 392 1245 1611115 136 148 330 1215 1549 629110 113 118 265 1142 1347105 92 88 194 958 1044 485100 75 67 122 674 74795 38 48 51 366 430 20690 3 1 5 97 139
ANGLE 0 45 90 135 180 OUTPUTLUMENS
RCC 80 70 50 30 10 0
RCR
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Floor Cavity Reflectance .20
CC-AI-3014T8-LP/ELB 79.5 % EfficiencyLitecontrol Certified Test Report #29611000
0 .76 .76 .76 .76 .65 .65 .65 .65 .44 .44 .44 .25 .25 .25 .08 .08 .08 .001 .69 .66 .63 .60 .59 .56 .54 .51 .38 .37 .36 .22 .21 .21 .07 .07 .07 .002 .62 .57 .53 .49 .53 .49 .45 .42 .34 .31 .29 .19 .18 .17 .06 .06 .06 .003 .57 .50 .45 .41 .49 .43 .39 .35 .30 .27 .25 .17 .16 .15 .05 .05 .05 .004 .52 .44 .38 .34 .44 .38 .33 .30 .26 .23 .21 .15 .14 .12 .05 .04 .04 .005 .48 .38 .33 .29 .40 .34 .29 .25 .23 .20 .18 .13 .12 .11 .04 .04 .03 .006 .44 .35 .29 .25 .37 .30 .25 .22 .21 .18 .15 .12 .10 .09 .04 .03 .03 .007 .40 .31 .25 .21 .34 .27 .22 .19 .18 .15 .13 .11 .09 .08 .03 .03 .03 .008 .37 .28 .22 .18 .31 .24 .19 .16 .17 .14 .11 .10 .08 .07 .03 .03 .02 .009 .34 .25 .20 .16 .29 .22 .17 .14 .15 .12 .10 .09 .07 .06 .03 .02 .02 .00
10 .32 .23 .18 .14 .27 .20 .15 .12 .14 .11 .09 .08 .06 .05 .03 .02 .02 .00
ZONAL LUMEN SUMMARY% %
ZONE LUMENS LAMP LUMINAIRE
180-90° 2305 79.51 100.0090-0° 0 .00 .00180-0° 2305 79.51 100.00
CANDLEPOWER SUMMARY0° PLANE PERPENDICULAR TO LAMPS
180 467 467 467 467 467175 470 469 467 469 475 45170 474 473 463 481 494165 464 474 454 489 510 135160 419 456 442 494 529155 378 419 430 500 559 212150 336 378 408 504 595145 297 338 392 509 690 276140 258 299 367 533 795135 224 257 339 589 885 340130 189 221 309 659 955125 156 186 278 709 954 386120 134 153 243 741 1048115 108 120 205 753 1056 408110 89 88 165 744 1016105 69 69 125 674 775 337100 56 48 80 489 62795 31 34 36 360 439 17190 1 3 4 98 128
ANGLE 0 45 90 135 180 OUTPUTLUMENS
PHOTOMETRIC DATA
90˚
120˚
150˚180˚
0˚60˚
30˚
Across45Along
RCC 80 70 50 30 10 0
RCR
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Floor Cavity Reflectance .20
CC-AI-3024BX-ELB 74.5 % EfficiencyLitecontrol Certified Test Report #29620000
0 .71 .71 .71 .71 .61 .61 .61 .61 .41 .41 .41 .24 .24 .24 .08 .08 .08 .001 .65 .62 .59 .57 .55 .53 .51 .48 .36 .35 .34 .21 .20 .20 .07 .06 .06 .002 .59 .54 .49 .46 .50 .46 .42 .40 .31 .29 .28 .18 .17 .16 .06 .06 .05 .003 .54 .47 .42 .38 .46 .40 .36 .33 .28 .25 .23 .16 .15 .14 .05 .05 .04 .004 .49 .41 .36 .32 .41 .36 .31 .28 .24 .22 .20 .14 .13 .12 .05 .04 .04 .005 .45 .36 .31 .27 .38 .32 .27 .24 .22 .19 .17 .13 .11 .10 .04 .04 .03 .006 .41 .33 .27 .23 .35 .28 .23 .20 .19 .16 .14 .11 .10 .08 .04 .03 .03 .007 .38 .29 .24 .20 .32 .25 .21 .17 .17 .14 .12 .10 .08 .07 .03 .03 .02 .008 .35 .26 .21 .17 .29 .23 .18 .15 .16 .13 .11 .09 .08 .06 .03 .02 .02 .009 .32 .24 .18 .15 .27 .20 .16 .13 .14 .11 .09 .08 .07 .06 .03 .02 .02 .00
10 .30 .21 .17 .13 .25 .18 .14 .12 .13 .10 .08 .08 .06 .05 .02 .02 .02 .00
ZONAL LUMEN SUMMARY% %
ZONE LUMENS LAMP LUMINAIRE
180-90° 4696 74.54 100.0090-0° 0 .00 .00180-0° 4696 74.54 100.00
CANDLEPOWER SUMMARY0° PLANE PERPENDICULAR TO LAMPS
180 963 963 963 963 963175 898 916 961 1006 1046 93170 827 862 954 1061 1127165 776 811 935 1117 1219 274160 701 766 907 1156 1309155 631 705 882 1204 1394 440150 565 638 843 1253 1477145 500 572 802 1289 1604 585140 440 506 754 1331 1745135 383 440 694 1382 1879 711130 326 376 633 1469 2015125 267 321 567 1540 2044 807120 229 264 497 1617 2194115 188 209 416 1649 2168 843110 154 164 339 1598 1956105 116 121 247 1395 1377 660100 100 91 153 929 109295 45 63 62 587 635 28990 1 1 5 118 158
ANGLE 0 45 90 135 180 OUTPUTLUMENS
1-T8
2-BX
2-T8
Revised 01/16/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
IDA-2S54@120Brand Name ROVR
Ballast Type Electronic Dimming
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamps
Rated
Lamp
Watts
Min.
Start
Temp
(°F/C)
Input
Current
(Amps)
Input Power
(Watts)
(min/max)
Ballast Factor
(min/max)
MAX
THD
%
Power
Factor
Lamp
Current
Crest Factor
B.E.F.
* F54T5/HO 2 54 50/10 1.05 24/125 0.03/1.00 10 0.98 1.7 0.80
FC12T5/HO 2 55 50/10 0.96 24/114 0.03/1.00 10 0.98 1.7 0.88
FT55W/2G11 2 55 50/10 0.96 24/114 0.03/1.00 10 0.98 0.0 0.88
Wiring Diagram
BALLAST
LAMP
RED
LAMP
YELLOW
BLUEBLACKWHITE
LINE
PURPLEPURPLE{
DALIClass 1 or
Class 2 Circuitoo
The wiring diagram that appears above is for
the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 0 0
White 0 0
Blue 0 0
Red 0 0
Yellow 0 0
Gray 0
Violet 0
in. cm.
Yellow/Blue 0
Blue/White 0
Brown 0
Orange 0
Orange/Black 0
Black/White 0
Red/White 0
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
16.70 " 1.18 " 1.00 " 16.34 "
16 7/10 1 9/50 1 16 17/50
42.4 cm 3 cm 2.5 cm 41.5 cm
IDA-2S54@120Brand Name ROVR
Ballast Type Electronic Dimming
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Notes:
Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements.
1.3 Ballast shall be provided with poke-in wire trap connectors or integral leads color coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Programmed Start.
2.2 Ballast shall be provided with integral protection circuitry to withstand connection of low voltage control leads to mains power supply. In
this event, ballast shall default to maximum light output.
2.3 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.4 Ballast shall operate from 50/60 Hz input source of 120V or 277V with sustained variations of +/- 10% (voltage and frequency) with no
damage to the ballast. IntelliVolt models shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10%
(voltage and frequency) with no damage to the ballast.
2.5 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared
devices and eliminate visible flicker.
2.6 Ballast shall have a Power Factor greater than 0.98 at full light output and greater than 0.90 throughout the dimming range for primary lamp.
2.7 Ballast shall have a minimum ballast factor of 1.00 at maximum light output and 0.03 at minimum light output for primary lamp application.
2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less throughout the dimming range in accordance with lamp manufacturer
recommendations.
2.9 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.10 Ballast shall have a Class A sound rating.
2.11 Ballast shall have a minimum starting temperature of 10C (50F) for primary lamp.
2.12 Ballast shall provide Lamp EOL Protection Circuit for all T5, T5/HO, CFL lamps, and T8 lamps operating on 4-lamp ballast.
2.13 Ballast shall control lamp light output from 100% - 3% relative light output for T8 and CFL lamps and 100% - 1% relative light output for
T5/HO lamps.
2.14 Ballast shall ignite the lamps at any light output setting without first going to another output setting.
2.15 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.4 Ballast shall comply with ANSI C82.11 where applicable.
3.5 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated).
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 70C.
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
4.4 Ballast shall be controlled by a Class 1 or Class 2 low voltage DALI controller.
4.5 Ballast shall be Advance part # _____________ or approved equal.
Revised 01/16/2004
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018TELEPHONE: (847) 390-5000 FAX: (847) 390-5109
F54T5/830 HOALTO TGProduct family description
Product dataProduct Number 168617Full product name F54T5/830 HO ALTO TGOrdering Code F54T5/830/HO/ALTO TGPack type 1 LampPieces per Sku 1Skus/Case 40Pack UPC 046677168612EAN2USCase Bar Code 50046677168617Successor Product numberSystem Description High OutputBase Miniature BipinBase Information Green [Green Base]Bulb T5 [16mm]Packing Type 1LP [1 Lamp]Packing Configuration 40Rated Avg. Life 24000 hrName Type F54T5Feature ALTO®Ordering Code F54T5/830/HO/ALTO TGPack UPC 046677168612Case Bar Code 50046677168617Watts 54WDimmable YesMercury (Hg) Content 1.4 mgColor Code 830 [CCT of 3000K]Color Rendering Index 85 Ra8
1
11/4/2007
Product dataColor Designation 830Color Description na [-]Color Temperature 3000 KInitial Lumens - LmOverall Length C 1163.2 mmDiameter D 17 mmProduct Number 168617
TL5
Base Miniature Bipin
Life Expectancy 3h cycleTL5
Life Expectancy 12h cycleTL5
Service Life 3h cycleTL5
Service Life 12h cycleTL5
2
11/4/2007
TL5/830 TL5/830
TL5
TL5
A B B C D
Fullproduct name
Max Min Max Max Max
F54T5/830 HOALTO
TG1149.0 1153.7 1156.1 1163.2 17
3
11/4/2007
FeaturesTriples-H 232/7 is an efficient 7” aperture low brightness downlight, for
use with two 32-watt, 4-pin, triple tube compact fluorescent lamps by GE,
Sylvania or Philips. Triples-H 232/7 provides shielding angles of 40° parallel
to and 40° perpendicular to the lamps. Recess depth is only 7 ¼”.
One housing allows interchangeable use of downlight and wallwash reflec-
tors, permitting housings to be installed first and reflectors to be installed
or changed at any time.
Triples-H 232/7 uses two 32-watt, 4-pin, triple tube lamps providing 4800
lumens (more than a 250-watt incandescent), a 10,000-hour life, a color
rendering index (CRI) of 82, and color temperatures as warm as 2700°K
(nearly duplicating the color qualities of incandescent).
Reflectors are available in clear, natural aluminum in three finishes: Even-
Tone, our standard clear finish, partially diffuse, anti-iridescent and gently
luminous in appearance; OptiTone, specular and anti-iridescent, with
minimum brightness and maximum efficiency; and EasyTone, diffuse and
luminous. Additionally, reflectors are available in champagne gold, wheat,
pewter, and bronze. Wallwash (120°) and double wallwash (2x120°)
reflectors are also available.
Triples-H 232/7 includes a pair of mounting bars (¾” x 27” C channel).
Specialty bars for wood joist and T-bar installations are available as
accessories.
aPPLICatIONsFixture is recommended for downlighting or wallwashing in offices, stores,
banks, schools, auditoriums, hospitals and airports, as well as lobbies
and public areas.
Fixture is listed for Damp Location (may not be suitable for some
outdoor environments). Fixture is in compliance with the component based
efficiency standards of the 1995 New York State
Energy Conservation Code. Fixture is prewired
with high power factor Class P
electronic ballast, suit-
able for use in a fire
rated ceiling and ap-
proved for eight #12
wire 75°C branch circuit
pull-through wiring. Removal of
the reflector allows access to the ballast and junction box.
TRIPLES-H 232/7r e c e s s e d c o m p a c t f l u o r e s c e n t d o w n l i g h t / w a l l w a s h e r
Requires ceiling opening of 7 15/16” (202mm)
©Copyright, Edison Price Lighting 2006 10-0641-50 22ND STREET, L IC NY 11101 tel 718.685.0700 fax 718.786.8530 www.epl.com
For combinations of the Options above, contact factory or Edison Price Lighting representative. A modified fixture suitable for 2” maximum ceiling thickness is available on special order. Contact factory. A modified fixture suitable for 347-volt service is available on special order. Contact factory. An install-from-below version of this fixture, suitable for installation outside North America, is also available. Contact factory. Decorative reflector rings are available on special order. Contact factory.
PrODuCt CODeFor complete product code, list basic unit and select one item from each following box.
Basic Unit ................................................................ TRPH 232/7
Reflector Type Downlight ....................................................................no suffix Wallwash ......................................................................... WW Double Wallwash ............................................................ DWW
Voltage 120 volt service ............. 120 277 volt service ................ 277
Reflector and Flange Color Overlap FlushEvenTone Clear ........................... VOL ..................................VFLOptiTone Clear ...........................COL ................................. CFLEasyTone Clear .......................... ECOL ...............................ECFLChampagne Gold .......................GOL .................................GFLWheat ..................................... WHOL ............................WHFLPewter ....................................... POL .................................. PFLBronze ....................................... ZOL ..................................ZFLOther reflector finishes are available on special order.
Standard reflector flange continues reflector finish. White painted flanges and custom painted flanges are available on special order. Add WF (white flange) or CCF (custom color flange).
OPtIONsSpecify by adding to the basic unit.Dimmable 3-wire ballast; not for outdoor application ...............– DMEmergency battery pack operates one lamp in event of power outage. Fixture footprint increases to 10 x 17 ¾” (254 x 451mm). Additional 1 ” (25mm) is required to remove EM pack through aperture. Not for outdoor application or double wallwasher (DWW) ............................. – EM1/8” (3mm) thick clear acrylic shield, spring-mountedwithin reflector ..................................................................... – PS
COMPACT FLUORESCENT
1-382
TRIPLes-h 232/7
Vertical Average Average Average Angle 0° Longitude 90° Longitude 180° Longitude
45 34788 42262 43032 55 542 1355 1558 65 368 368 368 75 150 150 300 85 0 0 0
LUMINANCE DATA (Candela/m2)
COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHODEffective Floor Cavity Reflectance 20%
Ceiling Reflectance (%) 80 70 50 30 10 0
Wall Reflectance (%) 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio
0 61 61 61 61 60 60 60 60 57 57 57 55 55 55 53 53 53 52 1 58 56 55 54 57 55 54 53 53 52 51 51 50 50 48 48 48 47 2 55 52 49 47 53 51 49 47 49 47 46 48 46 45 43 43 43 43 3 51 47 44 42 50 47 44 42 45 43 41 44 42 40 39 39 39 39 4 48 43 40 37 47 43 40 37 42 39 37 41 38 36 35 35 35 35 5 45 40 36 34 44 39 36 33 38 35 33 37 35 33 32 32 32 32 6 42 37 33 30 41 36 33 30 35 32 30 35 32 30 29 29 29 29 7 39 34 30 27 39 33 30 27 33 29 27 32 29 27 26 26 26 26 8 37 31 27 25 36 31 27 25 30 27 25 30 27 25 24 24 24 24 9 35 29 25 23 34 29 25 23 28 25 23 28 25 23 22 22 22 22 10 33 27 23 21 32 27 23 21 26 23 21 26 23 21 20 20 20 20
To convert cd/m2 to footlamberts, multiply by 0.2919.
ZONAL LUMEN SUMMARY
Zone Lumens % Lamp % Fixture 0 - 30° 1143 23.8 45.7 0 - 40° 1860 38.7 74.4 0 - 60° 2496 52.9 99.8 0 - 90° 2500 52.1 100.0 90 - 180° 0 0.0 0.0 0 - 180° 2500 52.1 100.0
PHOTOMETRIC REPORT
Luminaire .......... recessed compact fluorescent downlight with spun aluminum reflectorLamp ................ two Philips 32-watt triple-tube compact fluorescent, 4-pin, GX24q-3 base, 2400 lumens eachEfficiency ..........52.1%Spacing Criteria ...0°- 1.3, 90°-1.4, 180°-1.4Axis orientation ...0° plane is parallel to lamps, opposite sockets
ReportNo.50244.OriginalIndependentTestingLaboratories,Inc.(ITL)testreportfurnisheduponrequest.
TRIPLes-h 232/7 WW
3’ From Wall; 3’ O.C. 3’6” From Wall; 3’6” O.C. 4’ From Wall; 4’ O.C.
Below Between Below Between Below Between Fixture Fixtures Fixture Fixtures Fixture Fixtures
1 10 9 6 5 4 3 2 18 17 12 11 8 8 3 25 24 16 15 11 10 4 30 30 21 21 14 14 5 28 28 22 22 17 17 6 24 24 20 21 17 17 7 20 20 18 18 16 16 8 17 16 15 15 14 14 9 13 13 13 13 12 12 10 11 11 11 11 10 10 11 9 9 9 9 9 9 12 7 7 8 7 8 8
DistanceFrom
Ceiling(Feet)
All vertical footcandles are initial values with no contribution from ceiling or floor reflectances. Computation performed with at least five wallwashers.
WALLWASH INFORMATION
CANDLEPOWER DISTRIBUTION (Candela) 0.0 45.0 90.0 135.0 180.0
0 1263 1263 1263 1263 1263 5 1274 1304 1326 1307 1263 15 1280 1403 1536 1434 1272 25 1292 1348 1379 1372 1282 35 1007 1167 1171 1180 1130 45 633 726 769 812 783 55 8 14 20 21 23 65 4 4 4 4 4 75 1 1 1 1 2 85 0 0 0 0 0 90 0 0 0 0 0
Vertical Angle
Horizontal Angle
BALLAST INFORMATION Voltage 120 277 Input Watts 69 67 Line Current (A) .58 .26 Power Factor (%) >98 >98 THD (%) <10 <10 Min. Starting Temp* (°F) 0 0
*Consult lamp manufacturers for specific temperatures.
Revised 08/27/2003
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
IZT-2T42-M3-BS@277Brand Name MARK 7 0-10V
Ballast Type Electronic Dimming
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamps
Rated
Lamp
Watts
Min.
Start
Temp
(°F/C)
Input
Current
(Amps)
Input Power
(Watts)
(min/max)
Ballast Factor
(min/max)
MAX
THD
%
Power
Factor
Lamp
Current
Crest Factor
B.E.F.
* CFM32W/GX24Q 2 32 50/10 0.27 19/75 0.05/1.00 10 0.98 1.4 1.33
CFM42W/GX24Q 2 42 50/10 0.35 18/96 0.05/1.00 10 0.99 1.4 1.04
CFTR57W/GX24Q 1 57 50/10 0.24 18/66 0.05/1.00 10 0.99 1.6 1.52
CFTR70W/GX24Q 1 70 50/10 0.29 18/80 0.05/1.00 10 0.99 1.6 1.25
Wiring Diagram
WIRING: (2) TRIPLE LAMPS
Green Terminal must be Grounded
GREENGREY (-)
BLACK
WHITEVIOLET(+)
BALLAST
LINE BLUE
RED
YELLOWCLASS 1&2CIRCUIT
10V, 0.5mA
The wiring diagram that appears above is for
the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 0 0
White 0 0
Blue 0 0
Red 0 0
Yellow 0 0
Gray 0 0
Violet 0 0
in. cm.
Yellow/Blue 0
Blue/White 0
Brown 0
Orange 0
Orange/Black 0
Black/White 0
Red/White 0
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
6.28 " 3.00 " 1.29 " 2.00 "
6 7/25 3 1 29/100 2
16 cm 7.6 cm 3.3 cm 5.1 cm
PL-T 32W/830GX24q-3 /4P 1CTProduct family descriptionPL-T Triple 4pin Fluorescent Lamp withAmalgam.
Features/Benefits• ALTO® Lamp Technology - Passes EPA's TCLP test for non-hazardous waste.• Utilizes amalgam technology to provide > 90% of rated lumens in ambient temperatures from 23F to 130F.• Triple tube design available in 18, 26, 32, and 42W.• Excellent Color Rendering - 82 Color Rendering Index (CRI).• Broad Range of Color Temperature - Available in 2700, 3000, 3500 and 4100K.• Dimmable - PL-T 4-pin lamps may be used with electronic dimming ballasts.• Long Life - 12,000 hours.• Energy Saving - Designed for use with electronic ballasts for lower operating costs and flicker-free starting.
Applications• Ideal for downlights and medium bay multi-lamp fixtures for general lighting.
Notes• Rated average life under specified test conditions with lamps turned off and restarted no more frequently than
once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. (202)• Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating
life, when the output is measured during operation on a reference ballast under standard laboratory conditions.(203)
• Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output isbased upon measurements obtained during lamp operation on a reference ballast under standard laboratoryconditions. (208)
Product dataProduct Number 268326Full product name PL-T 32W/830 GX24q-3 /4P 1CTOrdering Code PL-T 32W/830/4P/ALTOPack type 1 Lamp in a Folding CartonPieces per Sku 1Skus/Case 12Pack UPC 046677268329
1
11/4/2007
Product dataEAN2USCase Bar Code 50046677268324Successor Product numberBase GX24q-3Base Information 4PExecution /4P [4 Pins]Packing Type 1CT [1 Lamp in a Folding Carton]Packing Configuration 12Avg. Hrs. Life 12000 hrOrdering Code PL-T 32W/830/4P/ALTOPack UPC 046677268329Case Bar Code 50046677268324Watts 32WLamp Voltage - VDimmable YesColor Code 830 [CCT of 3000K]Color Rendering Index 82 Ra8Color Designation Warm WhiteColor Description 830 Warm WhiteColor Temperature 3000 KInitial Lumens - LmInitial Lumens 2400 LmOverall Length C 141.4 mmDiameter D 39.85 mmDiameter D1 39.65 mmProduct Number 268326
PL-T 32W
PL-T
2
11/4/2007
PL-T/830 PL-T/830
3
11/4/2007
iW Profile g2
The iW Profile g2 fixture is a low-profile, linear 12” (30.2 cm) system that features higher light output and enhanced light quality with new optics and advanced LEDs (as compared to the previous generation). The linear design and fixture-to-fixture color consistency of this high-quality white light is well suited for display, museum, exhibit, retail, hospitality and architectural applications. iW Profile g2 provides flexible color temperature and brightness control through Chromacore®
technology, the proven approach that underlies Color Kinetics' existing intelligent solid-state lighting systems. When applied to IntelliWhite™ products, Chromacore controls channels of warm white and cool white LEDs to produce color temperatures within the range of 3000–6500 Kelvin from within a single fixture. iW Profile g2 allows the adjustment of light intensity while providing the option to either maintain or vary the color temperature.
iW Profile g2 is available with three different beam angles to meet diverse application demands: narrow, medium, and forward-throw asymmetric. iW Profile g2 is rated for indoor and damp location installations. The end-to-end locking connectors, capable of making 180º turns, make iW Profile g2 extremely versatile and easily adaptable to even the most challenging mounting environments.
iW Profile g2 is track mounted using the provided eight inch long 0º/60º track or 45º track for forward-throw asymmetric fixtures. This track allows for a light aim perpendicular to the mounting surface, angled at 60º from center, or angled at 45º from center. Optional 5 1/2 foot tracks are available for long, linear runs of 0º/45º/60º mounting angles.
iw profile g2 specif icationscolor temp range 3000K to 6500Ksource High intensity LEDsbeam angle Narrow, Medium, Forward-Throw Asymmetric housing Aluminum with enamel finishlens Clear tempered UV resistant lensconnectors Unified power and data cablelistings UL/cUL, CE communications specif ications data interface Color Kinetics iW PDS-150 or iW PDS-60 control Color Kinetics Line of Controllers, including iW Scene Controller, or LSM*
electrical specif icationspower requirement 24VDCpower consumption 15Wenvironmental specif icationstemperature range -4°F to 122°F (-20°C to 50°C) based on testing of specific product protection rating IP60 (top of housing); IP50 (bottom of housing)
* For large or complex installations, consider controlling iW Profile g2 with Light System Manager (LSM). Refer to the LSM data sheets or contact [email protected] for more information.
leD source life In traditional lamp sources, lifetime is defined as the point at which 50% of the lamps fail. This is also termed Mean Time Between Failure [MTBF]. LEDs are semiconductor devices and have a much longer MTBF than conventional sources. However, MTBF is not the only consideration in determining useful life. Color Kinetics uses the concept of useful light output for rating source lifetimes. Like traditional sources, LED output degrades over time (lumen depreciation) and this is the metric for SSL lifetime.
LED lumen depreciation is affected by numerous environmental conditions such as ambient temperature, humidity, and ventilation. Lumen depreciation is also affected by means of control, thermal management, current levels, and a host of other electrical design considerations. Color Kinetics systems are expertly engineered to optimize LED life when used under normal operating conditions. Lumen depreciation information is based on LED manufacturers’ source life data as well as other third party testing. Low temperatures and controlled effects have a beneficial effect on lumen depreciation. Overall system lifetime could vary substantially based on usage and the environment in which the system is installed.
Temperature and effects will affect lifetime. Color Kinetics rates product lifetime using lumen depreciation to 70% of original light output. When the fixture is running on warm or cool, at room temperature, the LED lifetime is in the range of 50,000 – 70,000 hours. This is based on LED manufacturers’ test data. High output is defined as any LED device that is 1/2 watt or above. For more detailed information on source life, please see www.colorkinetics.com/lifetime.
item# 501-000010-00 (medium) 501-000010-01 (narrow) 501-000010-02 (forward-throw asymmetric)
This product is protected by one or more of the following patents: U.S. Patent Nos. 6,016,038, 6,150,774 and other patents listed at
http://colorkinetics.com/patents/. Other patents pending.
©2006 Color Kinetics Incorporated. All rights reserved. Chromacore, Chromasic, Color Kinetics, the Color Kinetics
logo, ColorBlast, ColorBlaze, ColorBurst, ColorCast, ColorPlay, ColorScape, Direct Light, iColor, iColor Cove, iPlayer, Optibin, Powercore, QuickPlay, Sauce, the Sauce logo, and Smartjuice
are registered trademarks and DIMand, EssentialWhite, eW, IntelliWhite, iW, and Light Without Limits are trademarks of Color
Kinetics Incorporated. All other brand or product names are trademarks or registered trademarks of their respective owners.
BRO185 Rev 04
Specifications subject to change without notice. Refer to www.colorkinetics.com for the most recent data sheet versions.
Color Kinetics Incorporated • 10 Milk Street, Suite 1100 • Boston, MA 02108 • USA
Tel 888 FULL RGB • Tel 617 423 9999 • Fax 617 423 9998 • [email protected] • www.colorkinetics.com
DRY
DAMP
WET
An INTELLIWHITE™ Product
®
iW Profile g2 - narrowphotometric performance
Color Kinetics Incorporated • 10 Milk Street, Suite 1100 • Boston, MA 02108 • USA
Tel 888 FULL RGB • Tel 617 423 9999 • Fax 617 423 9998 • [email protected] • www.colorkinetics.com
light output
total output power efficacy
(lumems) (watts) (lm/w)
all 118 12.0 9.8
warm 107 11.8 9.1
cool 118 11.8 10.0
source specifications
Lens: UV-resistant soft-focus polycarbonate lens
Source: 10 LEDs (5 warm white, 5 cool white)
Beam Angle: 10° X 110º (at 50% of peak illuminance)
Distribution: Symmetric direct illumination
CRI: 79 All, 73 Warm, 83 Cool
canDle power Distribution
-90 90
0
41 82 122 163
Measured on: AllBeam peak: 163 cdThin dashed line: Indicates 50% of peak
illuminance
Measured in Footcandles (top)/Lux (bottom).Measured on all, reflectance 0.
3’ 6’ 9’ 15’
1m 2m 3m 5m
19.7 4.3 1.8 0.6
212.1 46.3 19.4 6.5all
Note: Efficacy figures are for a complete tested fixture not simply a lamp source.
illuminance Distribution
Units: Footcandles (top)/Lux (bottom) 10.8 lux = 1 fcLocation: Centered 1’/0.3m from, and perpendicular to, surface Measured on: All, Reflectance 50%
3.0’/1.0m 3.0’/1.0m0’/0m
0.2 0.2 0.2 0.2 0.2 0.2
2.2 2.2 2.2 2.2 2.2 2.2
0.5 3.9 6.9 3.9 0.6 0.2
5.4 42.0 74.3 42.0 6.5 2.2
0.9 7.7 17.1 14.0 4.5 0.6
9.7 82.9 184.1 150.7 48.4 6.5
0.6 4.5 14.0 17.1 7.7 0.9
6.5 48.4 150.7 184.1 82.9 9.7
0.2 0.6 3.9 6.9 3.9 0.5
2.2 6.5 42.0 74.3 42.0 5.4
0.2 0.2 0.2 0.2 0.2 0.2
2.2 2.2 2.2 2.2 2.2 2.2
criIt is common practice in the lighting industry to use color rendering index (CRI) to compare the properties of various light sources. There are known deficiencies and limitations associated with CRI and as a result, it is not always an accurate indicator of good object color appearance. This is especially true for LED-based sources. Until a better method for measuring color rendering in LEDs is accepted, Color Kinetics measures CRI in accordance with the current CIE 13.3-1995 standard using the Ra calculation. The reference illuminants employed are the Planckian locus below 5000K and CIE Daylight reference above 5000K. All measurements for Color Kinetics products are performed by third party laboratories using NIST-traceable instruments.
1.0’/0.3m
6.0’/2.0m
3.0’/1.0m
2.0’/0.6m
4.0’/1.2m
5.0’/1.5m
iW Profile g2 - mediumphotometric performance
Color Kinetics Incorporated • 10 Milk Street, Suite 1100 • Boston, MA 02108 • USA
Tel 888 FULL RGB • Tel 617 423 9999 • Fax 617 423 9998 • [email protected] • www.colorkinetics.com
light output
total output power efficacy
(lumems) (watts) (lm/w)
all 120 12.0 10.0
warm 102 11.8 8.6
cool 127 11.8 10.8
source specifications
Lens: UV-resistant soft-focus polycarbonate lens
Source: 10 LEDs (5 warm white, 5 cool white)
Beam Angle: 50° X 50º
Distribution: Symmetric direct illumination
CRI: 79 All, 73 Warm, 83 Cool
canDle power Distribution
-90 90
0
32 63 95 126
Measured on: AllBeam peak: 126 cdThin dashed line: Indicates 50% of peak
illuminance
Measured in Footcandles (top)/Lux (bottom).Measured on all, reflectance 0.
3’ 6’ 9’ 15’
1m 2m 3m 5m
18.3 4.0 1.7 0.6
197.0 43.1 18.3 6.5all
Note: Efficacy figures are for a complete tested fixture not simply a lamp source.
illuminance Distribution
criIt is common practice in the lighting industry to use color rendering index (CRI) to compare the properties of various light sources. There are known deficiencies and limitations associated with CRI and as a result, it is not always an accurate indicator of good object color appearance. This is especially true for LED-based sources. Until a better method for measuring color rendering in LEDs is accepted, Color Kinetics measures CRI in accordance with the current CIE 13.3-1995 standard using the Ra calculation. The reference illuminants employed are the Planckian locus below 5000K and CIE Daylight reference above 5000K. All measurements for Color Kinetics products are performed by third party laboratories using NIST-traceable instruments.
illuminance Distribution
Units: Footcandles (top)/Lux (bottom) 10.8 lux = 1 fcLocation: Centered 1’/0.3m from, and perpendicular to, surface Measured on: All, Reflectance 50%
3.0’/1.0m 3.0’/1.0m0’/0m
0.2 0.3 0.3 0.3 0.3 0.2
2.2 3.2 3.2 3.2 3.2 2.2
0.3 3.9 7.4 4.0 0.4 0.2
3.2 42.0 79.7 43.1 4.3 2.2
0.3 7.4 17.9 14.5 4.0 0.3
3.2 79.7 192.7 156.1 43.1 3.2
0.3 4.0 14.5 17.9 7.4 0.3
3.2 43.1 156.1 192.7 79.7 3.2
0.2 0.4 4.0 7.4 3.9 0.3
2.2 4.3 43.1 79.7 42.0 3.2
0.2 0.2 0.3 0.3 0.3 0.2
2.2 2.2 3.2 3.2 3.2 2.2
1.0’/0.3m
6.0’/2.0m
3.0’/1.0m
2.0’/0.6m
4.0’/1.2m
5.0’/1.5m
iW Profile g2 - ASYMMETRICphotometric performance
Color Kinetics Incorporated • 10 Milk Street, Suite 1100 • Boston, MA 02108 • USA
Tel 888 FULL RGB • Tel 617 423 9999 • Fax 617 423 9998 • [email protected] • www.colorkinetics.com
source specifications
Lens: UV-resistant soft-focus polycarbonate lens
Source: 10 LEDs (5 warm white, 5 cool white)
Beam Angle: 20° X 40° X 100º
Distribution: Asymmetric direct illumination
CRI: 79 All, 73 Warm, 84 Cool
criIt is common practice in the lighting industry to use color rendering index (CRI) to compare the properties of various light sources. There are known deficiencies and limitations associated with CRI and as a result, it is not always an accurate indicator of good object color appearance. This is especially true for LED-based sources. Until a better method for measuring color rendering in LEDs is accepted, Color Kinetics measures CRI in accordance with the current CIE 13.3-1995 standard using the Ra calculation. The reference illuminants employed are the Planckian locus below 5000K and CIE Daylight reference above 5000K. All measurements for Color Kinetics products are performed by third party laboratories using NIST-traceable instruments.
0.2 0.3 0.4 0.3 0.2 0.2
2.2 3.2 4.3 3.2 2.2 2.2
0.3 2.4 4.4 2.6 0.5 0.2
3.2 25.8 47.4 28.0 5.4 2.2
0.5 6.2 13.4 10.1 2.7 0.4
5.4 66.7 144.2 108.7 29.1 4.3
0.4 4.3 13.2 15.0 6.2 0.5
4.3 46.3 142.1 161.5 66.7 5.4
0.2 0.5 4.0 7.4 4.0 0.4
2.2 5.4 43.1 79.7 43.1 4.3
0.2 0.2 0.2 0.2 0.2 0.2
2.2 2.2 2.2 2.2 2.2 2.2
light output
total output power efficacy
(lumens) (watts) (lm/w)
all 100 12.0 8.3
warm 90 11.8 7.6
cool 101 11.8 8.6
canDle power Distribution
-90 90
0
20 40 59 79
Measured on: AllBeam center: 79 cdThin dashed line: Indicates 50% of peak
illuminance
Measured in Footcandles (top)/Lux (bottom).Measured on all, reflectance 0.
3’ 6’ 9’ 15’
1m 2m 3m 5m
7.1 1.5 0.7 0.2
76.4 16.1 7.5 2.2
illuminance Distribution
Units: Footcandles (top)/Lux (bottom) 10.8 lux = 1 fcLocation: Centered 1’/0.3m from, and perpendicular to, surfaceMeasured on: All, reflectance model 50/%
3.0’/1.0m 3.0’/1.0m
1.0’/0.3m
6.0’/2.0m
0’/0m
3.0’/1.0m
2.0’/0.6m
4.0’/1.2m
5.0’/1.5m
all
Note: Efficacy figures are for a complete tested fixture not simply a lamp source.
1.13”
12.00”(30.48 cm)
1.41”(3.67 cm)
1.09”(2.77 cm)
TOP
SIDE
BOTTOM
0º/60º Track - 8” (20 cm) and 5.5’ (1.7m )
45º Track - 5.5’ (1.7m )
0.72”(1.84 cm)
1.49”(3.79 cm)
1.81”(4.60 cm)
1.13”(2.88 cm)
18º
45º
IN
OUT
’
’
0.66”
Unified power and data cable
24VDC (15W)
11 oz (0.3 kg)
power connector
power requirement
weight
iw profile g2item# 501-000010-00/01/02
iW Profile g2physical dimensions
Color Kinetics Incorporated • 10 Milk Street, Suite 1100 • Boston, MA 02108 • USA
Tel 888 FULL RGB • Tel 617 423 9999 • Fax 617 423 9998 • [email protected] • www.colorkinetics.com
100-240VAC
Power/Data Cable(18AWG/.82mm2 CSA, 3-conductor)
Maximum cable run from PDS-150to fixtures: 50 feet (15.2 m)
iW PDS-150
100-240VAC
Loop out connection for multiple power/data supplies
TERMINATOR DATA
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
FUSE
BLO
CK
FUSE
BLO
CK
FUSE
BLO
CK
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
BLK
WH
T
RED
FUSE
BLO
CK
FUSE
BLO
CK
FUSE
BLO
CK
iW PDS-150
iW Scene Controller
CO
NTR
OLL
ER
ZON
E N
ET
IN
ZON
E N
ET
OU
T ZO
NE
N
UM
BER
Out
put
Faul
t
Zone
Net
Hea
rt Be
at
Pow
er
CO
NTR
OLL
ER
ZON
E N
ET
IN
ZON
E N
ET
OU
T ZO
NE
N
UM
BER
Out
put
Faul
t
Zone
Net
Hea
rt Be
at
Pow
er
Maximum per iW PDS-150: 10 Maximum per run: 5 Maximum output used: 2
Maximum per iW PDS-150: 10 Maximum per run: 5 Maximum output used: 2
iW Profile g2functional flow diagram (iW PDS-150)
Color Kinetics Incorporated • 10 Milk Street, Suite 1100 • Boston, MA 02108 • USA
Tel 888 FULL RGB • Tel 617 423 9999 • Fax 617 423 9998 • [email protected] • www.colorkinetics.com
additional items
iW PDS-150 (ITEM# 509-000001-00)power/Data supply
controller Any Color Kinetics iW Controller
For complete installation instructions and safety precautions, refer to the iW Profile g2 User Guide and wiring diagrams located at www.colorkinetics.com/support.
N
I T E N
E
N
O
Z T
U
O
T E N
E
N
O
Z
OUT 1 OUT 2
iW PDS-60
T o fixtures
OUT 1 OUT 2 iW PDS-60
iW Scene Controller
N
I T E N
E
N
O
Z T
U
O
T E N
E
N
O
Z
CONTROLLER
CONTROLLER
Loop out connection for multiple power/data
supplies
Power/Data Cable (18 A WG/.82mm CSA) ,
3-conducto r , Maximum cable run
from iW PDS-60 to fixtures: 50 feet (15.2m)
2
iW Profile g2 fixturesMaximum: 4 per iW PDS-60
T o fixtures
iW Profile g2functional flow diagram (iW PDS-60)
optibin®
There are inherent variations in the fabrication processes of all semiconductor materials. For LEDs, this variance results in differences in the color and intensity of light out-put as well as electrical characteristics. Due to these differences, LED manufacturers sort production into “bins,” but insuring the availability of a single bin is very difficult. To minimize this issue and achieve optimal color consistency in its products, Color Kinetics has developed and uses a proprietary technology called Optibin. Optibin is an advanced production binning optimization process that minimizes the effects of LED variance for the best possible output uniformity in the final product. Color Kinetics Optibin technology gives you the most consistent control of color and intensity from product to product.
Color Kinetics Incorporated • 10 Milk Street, Suite 1100 • Boston, MA 02108 • USA
Tel 888 FULL RGB • Tel 617 423 9999 • Fax 617 423 9998 • [email protected] • www.colorkinetics.com
additional items
iW PDS-60 (ITEM# 509-000002-00)power/Data supply
controller Any Color Kinetics iW Controller
For complete installation instructions and safety precautions, refer to the iW Profile g2 User Guide and wiring diagrams located at www.colorkinetics.com/support.
10 LAM LIGHTING • 2930 SOUTH FAIRVIEW STREET • SANTA ANA • CA 92704-6598 • PHONE: 714-549-9765 • FAX: 714-662-4515 • WWW.LAMLIGHTING.COM
OB70(100% direct)OB72(direct/indirect)
series shielding up shielding down mounting length fi nish voltage options
1/T82/T8
L-lensWB-whitebaffl ePB-parabolicbaffl e
WM-wall mount 4’8’
SGW-semi-gloss white (refer to color chart in Product Selection Guide for other standard colors)CC-custom color
120277Dual347
EXAMPLE
project name: ___________________________________ type: ___________________________________ quantity: ____________________
ORDER
OB70 2/T8 O L WM 4 SGW 120 GLR– – – – – – –
SPECIFICATIONS
– – – – – – – –
Obround Wall Mount A B C
4’ 1/4” 49 3/32” 48 19/32” 6 1246 1233
8’ 1/4” 97 3/4” 97 3/16” 6 2481 2467
DIMENSIONS
GLR-GLR fuse and HLR holderGMF-GMF slow blow fuse and holderEM1-B70A or equalEM2-B50 or equalEM3-B100 or equalEM4-B60 or equalDIM1-Advance Mark VII dimmingDIM2-Advance Mark X dimmingDIM3-Lutron ECO-10 dimming ballastDIM4-Lutron Hi-Lume dimming ballast DIM5-Lutron ECO-10 TVE dimming ballastDIM6-Lutron Tu-Wire dimming ballast (for T8, 32W, 120-volt only)
O-openL-clear acrylic lens
lampconfi guration
Due to a program of continuous improvement, LAM Lighting reserves the right to make any variation in design or construction to the equipment described.
OBROUND WALL MOUNTW
ALL
MO
UN
T
Housing: Extruded aluminum in lengths up to 8 feet. Rows of more than 8 feet are joined internally with no visible fasteners. OB70 series is 100% direct and OB72 series is direct/indirect.Refl ector: Specular aluminum. Shielding: Choice of acrylic prismatic lens, white blade baffl e, or semi-specular parabolic baffl e for all series. For OB72 series, uplight can be open or shielded by clear acrylic lens.Mounting: Wall mount onlyElectrical: Instant start, normal light output, high power factor, sound rated A electronic ballast is standard. One-lamp ballast is 0.90 ballast factor, two, three and four-lamp ballasts are 0.88 ballast factor for 120 and 277 volt. One-lamp ballast is 1.17 ballast factor, two-lamp is 0.92, three-lamp is 0.97, and four-lamp is 0.85 for 347 volt.Finish: Semi-gloss white powder coat paint is standard. Choose from a variety of standard colors on our color chart. Custom colors are available.Certifi cation: UL and CUL listed. IBEW labeled.
BC
A
C C
AA
3 1/4” (83)
7 1/2” (190)OB701-T8 OB702-T8
OB721-T8 OB722-T8
LAMP CONFIGURATIONS
–
LAM LIGHTING • 2930 SOUTH FAIRVIEW STREET • SANTA ANA • CA 92704-6598 • PHONE: 714-549-9765 • FAX: 714-662-4515 • WWW.LAMLIGHTING.COM 11
PHOTOMETRICS
OBROUND WALL MOUNTW
ALL M
OU
NT
% Fixture % LampZone Lumens Output Output0-90° 2210 44.8 35.1
90-180° 2720 55.2 43.20-180° 4930 100.0 78.3
OB72-2-WB175
165155
145
135
125
115
105
95
90
85
75
65
55
45
35
1500
1250
1000
1000
1250
750
500
250
0
250
500
750 90
0
0 22 45 67 90180° 907 907 907 907 907175° 908 904 907 901 902165° 895 888 880 870 860155° 832 820 813 815 816145° 745 734 744 765 773135° 597 594 622 677 685125° 479 484 546 581 584115° 306 338 370 362 357105° 152 190 187 179 172
95° 30 36 19 15 1490° 0 0 0 0 085° 21 26 29 34 4275° 80 90 97 108 8465° 144 156 177 232 26755° 236 245 300 467 54845° 321 358 474 672 76735° 515 577 688 850 92525° 683 729 834 939 98015° 829 846 908 973 987
5° 907 905 913 911 9100° 910 910 910 910 910
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY % Fixture % Lamp
Zone Lumens Output Output0-90° 3010 100.0 47.8
90-180° 0 0.0 0.00-180° 3010 100.0 47.8
OB70-2-L
0 22 45 67 9090° 0 0 0 0 085° 39 38 40 33 3175° 111 109 88 99 10665° 224 168 122 149 19855° 443 395 332 343 36045° 754 713 656 611 57035° 1117 1118 1088 1049 102525° 1336 1341 1346 1343 133715° 1463 1463 1472 1470 1454
5° 1490 1485 1491 1484 14870° 1489 1489 1489 1489 148
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY % Fixture % Lamp
Zone Lumens Output Output0-90° 2548 100.0 40.4
90-180° 0 0.0 0.00-180° 2548 100.0 40.4
OB70-2-WB
90
85
75
55
45
35
25
1550
65
0
250
500
750
1000
1250
1500
0 90
0 22 45 67 9090° 0 0 0 0 085° 17 19 24 28 3675° 89 93 102 113 8165° 166 172 194 246 27355° 269 275 325 487 56245° 379 418 533 715 80935° 637 701 808 957 103425° 867 920 1015 1119 116215° 1113 1140 1155 1218 1226
5° 1172 1173 1183 1183 11880° 1181 1181 1181 1181 1181
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY % Fixture % Lamp
Zone Lumens Output Output0-90° 2910 100.0 46.2
90-180° 0 0.0 0.00-180° 2910 100.0 46.2
OB70-2-PB
0 22 45 67 9090° 0 0 0 0 085° 0 0 0 1 175° 8 8 10 12 1465° 32 38 75 121 12655° 330 391 497 546 56845° 730 757 798 894 94135° 1018 1044 1056 1089 111525° 1194 1219 1224 1246 125615° 1323 1336 1361 1371 1356
5° 1377 1374 1384 1381 13840° 1378 1378 1378 1378 1378
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY
90
85
75
55
45
35
25
1550
65
0
250
500
750
1000
1250
1500
090
90
85
75
55
45
35
25
1550
65
0
250
500
750
1000
1250
1500
0
90
12’
CeilingHeight
2' 4' 6' 8' 10'
MountingHeight
OB721-T8-O-PB-4, 1-Lamp, F32T8, 2950 lumens per lamp, 0.77 LLF, 0.90 Ballast FactorPOWER DENSITY IS 0.4 WATTS PER SQUARE FOOT Fixture Spacing: 6’Ceiling Mounting D i s t a n c e f r o m W a l l Floor Adjacent WallHeight Height 2’ 4’ 6’ 8’ 10’ Average Average9’ 8’ 9 8 6 4 2 6 510’ 8’ 8 7 5 3 2 6 510’ 9’ 8 7 6 4 3 6 4Reflectance: 80/50/20Light Loss Factor - 0.95 room depreciation, 0.95 fixture depreciation, 0.95 lamp depreciation, 0.90 ballast factor =.77 total LLF
APPLICATION DATA
Revised 04/28/2005
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
VOP-4P32-SCBrand Name OPTANIUM
Ballast Type Electronic
Starting Method Instant Start
Lamp Connection Parallel
Input Voltage 277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamp
s
Rated
Lamp
Watts
Min. Start
Temp
(°F/C)
Input
Current
(Amps)
Input
Power
(ANSI
Watts)
Ballast
Factor
MAX
THD
%
Power
Factor
MAX Lamp
Current
Crest Factor
B.E.F.
* F40T8 2 40 32/00 0.30 81 1.03 10 0.98 1.7 1.27
F40T8 3 40 32/00 0.38 108 0.93 10 0.98 1.7 0.86
Wiring Diagram
BALLAST
Diag. 71A
LAMP
WHITEBLACK BLUE
LINE
BLUE
LAMP
YELLOWYELLOW
REDRED
Insulate unused lead for 1000V
The wiring diagram that appears above is
for the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 25L 63.5
White 25L 63.5
Blue 31R 78.7
Red 31R 78.7
Yellow 39L 99.1
Gray 0
Violet 0
in. cm.
Yellow/Blue 0
Blue/White 0
Brown 0
Orange 0
Orange/Black 0
Black/White 0
Red/White 0
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
9.50 " 1.7 " 1.18 " 8.90 "
9 1/2 1 7/10 1 9/50 8 9/10
24.1 cm 4.3 cm 3 cm 22.6 cm
VOP-4P32-SCBrand Name OPTANIUM
Ballast Type Electronic
Starting Method Instant Start
Lamp Connection Parallel
Input Voltage 277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Notes:
Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be provided with integral leads color-coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Instant Start.
2.2 Ballast shall provide Independent Lamp Operation (ILO) for Instant Start ballasts allowing remaining lamp(s) to maintain full light output when
one or more lamps fail.
2.3 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.4 Ballast shall operate from 60 Hz input source of 120V, 277V or 347V as applicable with sustained variations of +/- 10% (voltage and
frequency) with no damage to the ballast.
2.5 Ballast shall be high frequency electronic type and operate lamps at a frequency between 42 kHz and 52 kHz to avoid interference with
infrared devices, eliminate visible flicker and avoid Article Surveillance System, such as anti-theft devices.
2.6 Ballast shall have a Power Factor greater than 0.98 for primary lamp.
2.7 Ballast shall have a minimum ballast factor for primary lamp application as follows: 0.75 for Low Watt, 0.85 for Normal Light Output, and
1.20 for High Light.
2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations.
2.9 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.10 Ballast shall have a Class A sound rating for all 4-foot lamps and smaller.
2.11 Ballast shall have a minimum starting temperature of 0F (-18C) and 60F (16C) for energy-saving T8 lamps.
2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.4 Ballast shall comply with ANSI C82.11 where applicable.
3.5 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated).
3.6 Ballast shall meet NEMA/CEE High Performance T8 Lighting System Specifications.
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 70C. Ballasts with a "90C" designation in their catalog number shall also carry a three-year
warranty at maximum case temperature of 90C.
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
4.4 Ballast shall be Advance part # _____________ or approved equal.
NOTE: The use of Optanium 2.0 (IOP) models is recommended to reduce striation in energy-saving T8 lamps (25W, 28W or 30W). Remote or
tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.
Revised 04/28/2005
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018TELEPHONE: (847) 390-5000 FAX: (847) 390-5109
F40T8 TL841 ALTOTGProduct family description
Product dataProduct Number 164392Full product name F40T8 TL841 ALTO TGOrdering Code F40T8/TL841/ALTO TGPack type 1 LampPieces per Sku 1Skus/Case 25Pack UPC 046677164393EAN2USCase Bar Code 50046677164398Successor Product numberBase Medium Bi-Pin [Medium Bi-Pin Fluorescent]Base Information Green BaseBulb T8Packing Type 1LP [1 Lamp]Packing Configuration 25Name Type F40T8Feature ALTO®Rated Avg. Life [3 hr Start] 20000 hrOrdering Code F40T8/TL841/ALTO TGPack UPC 046677164393Case Bar Code 50046677164398Energy Saving Product Energy SavingWatts 40WMercury (Hg) Content 3.5 mgColor Code TL841 [CCT of 4100K]Color Rendering Index 86 Ra8Color Designation TL841
1
24/3/2007
Product dataColor Temperature 4100 KInitial Lumens 3775 LmDesign Mean Lumens 3500 LmNominal Length [inch] 60Special Note TuffGuard™ [TuffGuard Coated]Product Number 164392
F-T8-RS Med Bipin/GB
Base Medium Bi-Pin
F-T8-RS Med Bipin
Energy Saving Product Energy Saving
2
24/3/2007
HP
APPLICATIONS
FEATURES
Designed to provide high efficiency general lighting for low-glare environments, the HPparabolic, grid troffer is typically used in offices, classrooms, and auditoriums.
12/02
PHOTOMETRY
This efficient, parabolic, grid troffer is available with static and air-handling options.The HP fixture series comes in 2x2 and 2x4 nominal sizes with a 5.2” fixture depth.
Deep cell, premium-grade aluminum louvers in choice of low-iridescent diffuse or specular louver finishes.
Black reveal provides floating louver appearance, conceals optional air-supply slots.
Integral T-bar safety clips are standard.
Flange option available.
SPECIFICATIONSHOUSING: Cold rolled, pre-painted steel housing is rigid and fully assembled with rivets.
REFLECTOR: Material is Miro® enhanced specular aluminum with a total reflectivity of 95%.
DIFFUSER: Louvers formed from premium-grade aluminum lighting sheet.
MOUNTING: The HP series fixture is suitable for mounting in NEMA type G ceiling systems. Flange option available for non-gridceiling types.
LAMPHOLDERS: T8 lamps are secured with locking lampholders.
©2002 Acuity Lighting Group, Inc. Visit our website at www.holophane.com Printed in USAHL-5096
2x2 Parabolic Grid Troffer
HPGS22XBD33O22Test #200180
Fixture Efficiency: 71.4%SC Across: 2.0, SC Along: 1.2
90°
60°
30°
300
600
MODELS AVAILABLE
CROSS SECTIONS
Holophane. Acuity Lighting Group, Inc. 214 Oakwood Ave., Newark, OH 43055 / Holophane Canada, Inc. 9040 Leslie Street,Units 8 and 9, Richmond Hill, ON L4B 3M4 / Holophane Europe Limited, Bond Ave., Milton Keynes MK1 1JG, England / Holophane,S.A. de C.V., Apartado Postal No. 986, Naucalpan de Juarez, 53000 Edo. de MexicoContact your local Holophane sales representative for application assistance, computer-aided design and cost studies. Forinformation on other Holophane products and systems, call the Inside Sales Service Department at 740-345-9631. In Canada, call905-707-5830 or fax 905-707-5695. HL-5096
23.8�
20.8�
5.2�
2.8�
5.2�
2.8�
23.8�
20.8�
2 Lamp
3 Lamp
Fixture Schedule Fixture ID#
Ballast TypeEP - Standard electronic
LP - Low-power electronicMP - Medium-power electronic
YP - High-power electronic
BallastVoltage1 - 120V2 - 277V3 - 347V
U - 120V/277VTandem Option2 - Tandem of 2
FixtureSeries
ReflectorMaterial
W - White ballastcover
X - Miro® enhancedaluminum
DiffuserD23 - Semi-specular 6 cell louverD33 - Semi-specular 9 cell louver
HP
PhotometryB - Broad
N - NormalS - Spread
HousingA - Air-handling
N - Static
Lamp ConfigurationO22 - 2 F17T8O23 - 3 F17T8O24 - 4 F17T8
BallastQuantity
123
G
Not all photometry and diffuser options available with every lamp configuration.Not all ballast types and quantities available with every lamp configuration.For additional ballast options please contact your local Holophane sales representative.
22
Drawings for dimensional detail only. Subject to change without notice.
Revised 10/28/2005
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
VEZ-3S32-SCBrand Name MARK 10 POWERLINE
Ballast Type Electronic Dimming
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamps
Rated
Lamp
Watts
Min.
Start
Temp
(°F/C)
Input
Current
(Amps)
Input Power
(Watts)
(min/max)
Ballast Factor
(min/max)
MAX
THD
%
Power
Factor
Lamp
Current
Crest Factor
B.E.F.
* F17T8 3 17 50/10 0.21 18/56 0.05/1.05 10 0.99 1.6 1.88
F25T8 3 25 50/10 0.29 19/79 0.05/1.05 10 0.99 1.6 1.33
F32T8 3 32 50/10 0.37 20/102 0.05/1.00 10 0.99 1.6 0.98
Wiring Diagram
BLUE
The wiring diagram that appears above is for
the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
9.50 " 1.7 " 1.18 " 8.90 "
9 1/2 1 7/10 1 9/50 8 9/10
24.1 cm 4.3 cm 3 cm 22.6 cm
F17T8 TL841 ALTOTGProduct family description
Product dataProduct Number 168989Full product name F17T8 TL841 ALTO TGOrdering Code F17T8/TL841/ALTO TGPack type 1 LampPieces per Sku 1Skus/Case 25Pack UPC 046677168988EAN2USCase Bar Code 50046677168983Successor Product numberBase Medium Bi-Pin [Medium Bi-Pin Fluorescent]Base Information Green BaseBulb T8Packing Type 1LP [1 Lamp]Packing Configuration 25Name Type F17T8Feature ALTO®Ordering Code F17T8/TL841/ALTO TGPack UPC 046677168988Case Bar Code 50046677168983Energy Saving Product Energy SavingWatts 17WMercury (Hg) Content 3.5 mgColor Code TL841 [CCT of 4100K]Color Rendering Index 85 Ra8Color Designation TL841Color Temperature 4100 K
1
24/3/2007
Product dataInitial Lumens 1400 LmDesign Mean Lumens 1330 LmNominal Length [inch] 24Special Note TuffGuard™ [TuffGuard Coated]Product Number 168989
F-T8-Unv Med Bipin/GB
Base Medium Bi-Pin
F-T8-Unv Med Bipin
Energy Saving Product Energy Saving
2
24/3/2007
10 LAM LIGHTING • 2930 SOUTH FAIRVIEW STREET • SANTA ANA • CA 92704-6598 • PHONE: 714-549-9765 • FAX: 714-662-4515 • WWW.LAMLIGHTING.COM
OB70(100% direct)OB72(direct/indirect)
series shielding up shielding down mounting length fi nish voltage options
1/T82/T8
L-lensWB-whitebaffl ePB-parabolicbaffl e
WM-wall mount 4’8’
SGW-semi-gloss white (refer to color chart in Product Selection Guide for other standard colors)CC-custom color
120277Dual347
EXAMPLE
project name: ___________________________________ type: ___________________________________ quantity: ____________________
ORDER
OB70 2/T8 O L WM 4 SGW 120 GLR– – – – – – –
SPECIFICATIONS
– – – – – – – –
Obround Wall Mount A B C
4’ 1/4” 49 3/32” 48 19/32” 6 1246 1233
8’ 1/4” 97 3/4” 97 3/16” 6 2481 2467
DIMENSIONS
GLR-GLR fuse and HLR holderGMF-GMF slow blow fuse and holderEM1-B70A or equalEM2-B50 or equalEM3-B100 or equalEM4-B60 or equalDIM1-Advance Mark VII dimmingDIM2-Advance Mark X dimmingDIM3-Lutron ECO-10 dimming ballastDIM4-Lutron Hi-Lume dimming ballast DIM5-Lutron ECO-10 TVE dimming ballastDIM6-Lutron Tu-Wire dimming ballast (for T8, 32W, 120-volt only)
O-openL-clear acrylic lens
lampconfi guration
Due to a program of continuous improvement, LAM Lighting reserves the right to make any variation in design or construction to the equipment described.
OBROUND WALL MOUNTW
ALL
MO
UN
T
Housing: Extruded aluminum in lengths up to 8 feet. Rows of more than 8 feet are joined internally with no visible fasteners. OB70 series is 100% direct and OB72 series is direct/indirect.Refl ector: Specular aluminum. Shielding: Choice of acrylic prismatic lens, white blade baffl e, or semi-specular parabolic baffl e for all series. For OB72 series, uplight can be open or shielded by clear acrylic lens.Mounting: Wall mount onlyElectrical: Instant start, normal light output, high power factor, sound rated A electronic ballast is standard. One-lamp ballast is 0.90 ballast factor, two, three and four-lamp ballasts are 0.88 ballast factor for 120 and 277 volt. One-lamp ballast is 1.17 ballast factor, two-lamp is 0.92, three-lamp is 0.97, and four-lamp is 0.85 for 347 volt.Finish: Semi-gloss white powder coat paint is standard. Choose from a variety of standard colors on our color chart. Custom colors are available.Certifi cation: UL and CUL listed. IBEW labeled.
BC
A
C C
AA
3 1/4” (83)
7 1/2” (190)OB701-T8 OB702-T8
OB721-T8 OB722-T8
LAMP CONFIGURATIONS
–
LAM LIGHTING • 2930 SOUTH FAIRVIEW STREET • SANTA ANA • CA 92704-6598 • PHONE: 714-549-9765 • FAX: 714-662-4515 • WWW.LAMLIGHTING.COM 11
PHOTOMETRICS
OBROUND WALL MOUNTW
ALL M
OU
NT
% Fixture % LampZone Lumens Output Output0-90° 2210 44.8 35.1
90-180° 2720 55.2 43.20-180° 4930 100.0 78.3
OB72-2-WB175
165155
145
135
125
115
105
95
90
85
75
65
55
45
35
1500
1250
1000
1000
1250
750
500
250
0
250
500
750 90
0
0 22 45 67 90180° 907 907 907 907 907175° 908 904 907 901 902165° 895 888 880 870 860155° 832 820 813 815 816145° 745 734 744 765 773135° 597 594 622 677 685125° 479 484 546 581 584115° 306 338 370 362 357105° 152 190 187 179 172
95° 30 36 19 15 1490° 0 0 0 0 085° 21 26 29 34 4275° 80 90 97 108 8465° 144 156 177 232 26755° 236 245 300 467 54845° 321 358 474 672 76735° 515 577 688 850 92525° 683 729 834 939 98015° 829 846 908 973 987
5° 907 905 913 911 9100° 910 910 910 910 910
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY % Fixture % Lamp
Zone Lumens Output Output0-90° 3010 100.0 47.8
90-180° 0 0.0 0.00-180° 3010 100.0 47.8
OB70-2-L
0 22 45 67 9090° 0 0 0 0 085° 39 38 40 33 3175° 111 109 88 99 10665° 224 168 122 149 19855° 443 395 332 343 36045° 754 713 656 611 57035° 1117 1118 1088 1049 102525° 1336 1341 1346 1343 133715° 1463 1463 1472 1470 1454
5° 1490 1485 1491 1484 14870° 1489 1489 1489 1489 148
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY % Fixture % Lamp
Zone Lumens Output Output0-90° 2548 100.0 40.4
90-180° 0 0.0 0.00-180° 2548 100.0 40.4
OB70-2-WB
90
85
75
55
45
35
25
1550
65
0
250
500
750
1000
1250
1500
0 90
0 22 45 67 9090° 0 0 0 0 085° 17 19 24 28 3675° 89 93 102 113 8165° 166 172 194 246 27355° 269 275 325 487 56245° 379 418 533 715 80935° 637 701 808 957 103425° 867 920 1015 1119 116215° 1113 1140 1155 1218 1226
5° 1172 1173 1183 1183 11880° 1181 1181 1181 1181 1181
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY % Fixture % Lamp
Zone Lumens Output Output0-90° 2910 100.0 46.2
90-180° 0 0.0 0.00-180° 2910 100.0 46.2
OB70-2-PB
0 22 45 67 9090° 0 0 0 0 085° 0 0 0 1 175° 8 8 10 12 1465° 32 38 75 121 12655° 330 391 497 546 56845° 730 757 798 894 94135° 1018 1044 1056 1089 111525° 1194 1219 1224 1246 125615° 1323 1336 1361 1371 1356
5° 1377 1374 1384 1381 13840° 1378 1378 1378 1378 1378
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY
90
85
75
55
45
35
25
1550
65
0
250
500
750
1000
1250
1500
090
90
85
75
55
45
35
25
1550
65
0
250
500
750
1000
1250
1500
0
90
12’
CeilingHeight
2' 4' 6' 8' 10'
MountingHeight
OB721-T8-O-PB-4, 1-Lamp, F32T8, 2950 lumens per lamp, 0.77 LLF, 0.90 Ballast FactorPOWER DENSITY IS 0.4 WATTS PER SQUARE FOOT Fixture Spacing: 6’Ceiling Mounting D i s t a n c e f r o m W a l l Floor Adjacent WallHeight Height 2’ 4’ 6’ 8’ 10’ Average Average9’ 8’ 9 8 6 4 2 6 510’ 8’ 8 7 5 3 2 6 510’ 9’ 8 7 6 4 3 6 4Reflectance: 80/50/20Light Loss Factor - 0.95 room depreciation, 0.95 fixture depreciation, 0.95 lamp depreciation, 0.90 ballast factor =.77 total LLF
APPLICATION DATA
Revised 04/28/2005
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCEO'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071Corporate Offices: Phone: 800-322-2086
VOP-4P32-SCBrand Name OPTANIUM
Ballast Type Electronic
Starting Method Instant Start
Lamp Connection Parallel
Input Voltage 277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Lamp Type Num.
of
Lamp
s
Rated
Lamp
Watts
Min. Start
Temp
(°F/C)
Input
Current
(Amps)
Input
Power
(ANSI
Watts)
Ballast
Factor
MAX
THD
%
Power
Factor
MAX Lamp
Current
Crest Factor
B.E.F.
* F40T8 2 40 32/00 0.30 81 1.03 10 0.98 1.7 1.27
F40T8 3 40 32/00 0.38 108 0.93 10 0.98 1.7 0.86
Wiring Diagram
BALLAST
Diag. 71A
LAMP
WHITEBLACK BLUE
LINE
BLUE
LAMP
YELLOWYELLOW
REDRED
Insulate unused lead for 1000V
The wiring diagram that appears above is
for the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
in. cm.
Black 25L 63.5
White 25L 63.5
Blue 31R 78.7
Red 31R 78.7
Yellow 39L 99.1
Gray 0
Violet 0
in. cm.
Yellow/Blue 0
Blue/White 0
Brown 0
Orange 0
Orange/Black 0
Black/White 0
Red/White 0
Enclosure
Enclosure Dimensions
OverAll (L) Width (W) Height (H) Mounting (M)
9.50 " 1.7 " 1.18 " 8.90 "
9 1/2 1 7/10 1 9/50 8 9/10
24.1 cm 4.3 cm 3 cm 22.6 cm
VOP-4P32-SCBrand Name OPTANIUM
Ballast Type Electronic
Starting Method Instant Start
Lamp Connection Parallel
Input Voltage 277
Input Frequency 50/60 HZ
Status Active
Electrical Specifications
Notes:
Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be provided with integral leads color-coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Instant Start.
2.2 Ballast shall provide Independent Lamp Operation (ILO) for Instant Start ballasts allowing remaining lamp(s) to maintain full light output when
one or more lamps fail.
2.3 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.4 Ballast shall operate from 60 Hz input source of 120V, 277V or 347V as applicable with sustained variations of +/- 10% (voltage and
frequency) with no damage to the ballast.
2.5 Ballast shall be high frequency electronic type and operate lamps at a frequency between 42 kHz and 52 kHz to avoid interference with
infrared devices, eliminate visible flicker and avoid Article Surveillance System, such as anti-theft devices.
2.6 Ballast shall have a Power Factor greater than 0.98 for primary lamp.
2.7 Ballast shall have a minimum ballast factor for primary lamp application as follows: 0.75 for Low Watt, 0.85 for Normal Light Output, and
1.20 for High Light.
2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations.
2.9 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.10 Ballast shall have a Class A sound rating for all 4-foot lamps and smaller.
2.11 Ballast shall have a minimum starting temperature of 0F (-18C) and 60F (16C) for energy-saving T8 lamps.
2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.4 Ballast shall comply with ANSI C82.11 where applicable.
3.5 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated).
3.6 Ballast shall meet NEMA/CEE High Performance T8 Lighting System Specifications.
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 70C. Ballasts with a "90C" designation in their catalog number shall also carry a three-year
warranty at maximum case temperature of 90C.
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
4.4 Ballast shall be Advance part # _____________ or approved equal.
NOTE: The use of Optanium 2.0 (IOP) models is recommended to reduce striation in energy-saving T8 lamps (25W, 28W or 30W). Remote or
tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.
Revised 04/28/2005
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018TELEPHONE: (847) 390-5000 FAX: (847) 390-5109
F40T8 TL841 ALTOTGProduct family description
Product dataProduct Number 164392Full product name F40T8 TL841 ALTO TGOrdering Code F40T8/TL841/ALTO TGPack type 1 LampPieces per Sku 1Skus/Case 25Pack UPC 046677164393EAN2USCase Bar Code 50046677164398Successor Product numberBase Medium Bi-Pin [Medium Bi-Pin Fluorescent]Base Information Green BaseBulb T8Packing Type 1LP [1 Lamp]Packing Configuration 25Name Type F40T8Feature ALTO®Rated Avg. Life [3 hr Start] 20000 hrOrdering Code F40T8/TL841/ALTO TGPack UPC 046677164393Case Bar Code 50046677164398Energy Saving Product Energy SavingWatts 40WMercury (Hg) Content 3.5 mgColor Code TL841 [CCT of 4100K]Color Rendering Index 86 Ra8Color Designation TL841
1
24/3/2007
Product dataColor Temperature 4100 KInitial Lumens 3775 LmDesign Mean Lumens 3500 LmNominal Length [inch] 60Special Note TuffGuard™ [TuffGuard Coated]Product Number 164392
F-T8-RS Med Bipin/GB
Base Medium Bi-Pin
F-T8-RS Med Bipin
Energy Saving Product Energy Saving
2
24/3/2007
DT-200 Dual Technology Sensor
• Advanced control logic based on RISC micro-
controller provides:
• Detection Signature Processing eliminates
false triggers and provides immunity to RFI
and EMI
• SmartSet automatically adjusts sensitivity and
time delay settings to fit occupant patterns
• Walk-through mode turns lights off 3 minutes
after the area is initially occupied – ideal for
brief visits such as mail delivery
• Available with built-in light level sensor
featuring simple, one-step setup
Watt Stopper/Legrand’s DT-200 Dual Technology
occupancy sensors combine passive infrared (PIR)
and ultrasonic technologies into one unit to
achieve precise coverage.
SmartSet
Operation
The DT-200 turns lighting on when both PIR and
ultrasonic technologies detect occupancy. It can
also work with a low voltage switch for manual-
ON operation. PIR technology senses the
difference between infrared energy from a
human body in motion and the background
space. Ultrasonic technology uses the Doppler
Principle and high frequency (40 kHz) ultrasound
to sense motion within the space. Once lighting
is on, detection by either technology holds light-
ing on. When no occupancy is detected for the
length of the time delay, lighting turns off. The
DT can also be set so that only one technology is
needed to trigger lighting on or both technologies
are needed to hold lighting on. The sensors are
low voltage and utilize a Watt Stopper power pack.
DescriptionProduct
Overview
Features • Sensors work with low voltage momentary
switches to provide manual control
• LEDs indicate occupancy detection
• 8 occupancy logic options give users the ability
to customize control to meet application needs
• Available with isolated relay for integration with
BAS or HVAC
• Swivel mounting bracket for convenient corner
mounting to wall or ceiling
Using SmartSet™ technology, the DT-200 sensors
require no adjustment at installation. SmartSet
monitors the controlled space to identify usage
patterns. Using this information, it automatically
adjusts the time delay and sensitivity for optimal
performance and energy efficiency. The sensor
assigns short delays (as low as 5 minutes) for
times when the space is usually vacant, and longer
delays (up to 30 minutes) for busier times.
Application
Watt Stopper/Legrand dual technology sensors
have the flexibility to work in a variety of applica-
tions. Mounted at 10 feet, the sensors can cover up
to 2000 square feet of walking motion and 1000
square feet of desktop motion. The sensors are
designed to control lighting in difficult applications,
such as classrooms, where one technology alone
could encounter false triggers. In addition to class-
rooms, the DT-200 works well in warehouses, large
offices, open office spaces, and computer rooms.
O c c u p a n c y S e n s o r s
www.wattstopper.com
8 0 0 . 8 7 9 . 8 5 8 5
PROJECT
LOCATION/TYPE
Accepts low voltage
switch input for
manual-on operation
Combines passive
infrared and ultrasonic
technologies
Built-in light level sensor
Walk-through mode
increases savings potential
SmartSet™ automatically
selects optimal settings
for each space
Wiring &
Mounting
Controls &
Settings
Coverage
Watt Stopper/Legrand®
Pub. No. 6204
Ordering
Information
Specifications • 24 VDC/VAC and halfwave rectified AC
• 40 kHz frequency ultrasonic transmission
• Time delays: SmartSet (automatic), fixed (5, 10,
15, 20, or 30 minutes), walk-through, test-mode
• Sensitivity adjustment: SmartSet (automatic) or
reduced sensitivity (for PIR sensitivity); ultra-
sonic sensitivity is variable with trimpot
• Built-in light level sensor (DT-200) – works from
2 to 200 footcandles (21 to 2,152 lux)
• Low voltage, momentary switch input for manual
operation
• DT-200 contains an isolated relay with N/O and
N/C outputs; rated for 1 Amp at 24 VDC/VAC
• 2000 ft2 of walking motion mounted at 10 ft; 1000
ft2 of desktop motion
• Units per power pack: DT-200: up to 2 (B), up to
3 (BZ); DT-205: up to 3 (B), up to 4 (BZ)
• Dimensions: 4.4" x 3.4" x 2"
(110.3mm x 85.9mm x 49.6mm) LxWxD
• UL and CUL listed; Five year warranty
DT-200 Technical Information
O c c u p a n c y S e n s o r s
DT-200
DT-205
24 VDC
24 VDC
Catalog No. Voltage Current Coverage Features
Sensors are white and use Watt Stopper power packs. Current consumption can be slightly higher when only one sensor per power pack is used.
43 mA
35 mA
2000 ft2 (185.8 m2)
2000 ft2 (185.8 m2)
light level, isolated relay
Wiring Diagram
DIP Switch Settings
Mounting
Product Controls
A swivel mounting
bracket, attached to
the sensor, allows
the sensor to be
angled for wall or
ceiling mounting.
Grooves on the
bracket help to
achieve desired
angle for coverage.
Wiring diagram includes bi-level control andmanual-on option with momentary switch
Coverages shown are maximum and represent half-step
walking motion. Under ideal conditions, with no barriers
or obstacles, coverage for half-step walking motion can
reach up to 2000 ft2 while coverage for typical desktop
activity can reach up to 1000 ft2.