AIRFIXFILTRATION, PURIFICATION, SANITIZATION
CERTIFICATED HEPA FILTERS
GERMICIDAL ACTION LABORATORY TESTED
ACTIVE SANIFICATION FOR AIR AND SURFACES
Thanks to a modern and essential designed vertical frame, you can position this product in every civil and industrial location, of medium and big surface. In spite of the airflow of 1600 mc/h, the unit is not very noisy, because of its internal insulation and the dimensioning of the fan section.
We guarantee the maximum duration of HEPA-13 filters, thanks to three filtration degrees.
AIRFIX unit includes:
A reusable and double containment mesh COARSE pre-filter on air suction side, at the bottom of the unit, so to hold dirt and dust
An ePM1 filter having low pressure drops and a wide filtering surface, used as cleanroom air pre-filtration
A HEPA 13 (or HEPA 14, as an option) positioned before the fan section. Its filtration degree ≥99,97%, combined to the UV lamps (as an option) grants an air optimal purification.
CERTIFIED UV-C LAMPS
CERTIFIED ACTIVE MODULE
3 CERTIFIED FILTERS
UP TO 1.600 m3/h
230V / 50Hz
LOW SOUND EMISSION
SUITABLE TO ALL ENVIRORMENT
250 - 350 WATT
INTENDED FOR ALL INDOOR ENVIRONMENTS WITH MEDIUM CROWDING, TO CONTRAST CONTAMINATION AND SPREAD OF BACTERIA AND VIRUSES, AIRFIX PROVIDES COMPLETE AIR FILTRATION AND EFFECTIVE PURIFICATION UP TO 99.97%.BASING ON ABSOLUTELY NON-TOXIC TREATMENTS, IT CAN BE USED WITHOUT TIME LIMITS AND WITH THE PRESENCE OF PEOPLE IN THE PREMISES.
WHERE
EC FAN
UV-C LAMPS
HEPA 13 FILTER
PURIFIED AIR FLOW
ePM1 60% FILTER
COARSE 70% FILTER
HIGH EFFICENCY
FILTER STATUS LED
CONTEMPORARY DESIGN
OFFICESCLASSROOMSMARKETSCLINICSBOUTIQUESEVENTS HALLTHEATERSCINEMASRESTAURANTSKITCHENSEXPOMUSEUMS
SIZES 700x500x1900 mm
AIRFLOW H13 from 800 to 1600 m3/hH14 from 800 to 1400 m3/h
POWER SUPPLY 230V/50Hz
ENERGY CONSUMPTION 250 - 350 W
TECHNICAL DATA
(En1822)
(ISO 16890)
(ISO 16890)
Electronic Brushless commutatedmotor fan
A POWERFULL UNIT DESIGNED FOR ENERGY SAVING
UP TO 1600 m3/h
Home purifiersn°1 Unit AIRFIX
EFFICIENCY AND QUALITY CERTIFICATED
HEPA 13 FILTER CERTIFICATEDISO 29463-3:2019
UV-C LAMPS CERTIFICATED ISO 15714:2019
FILTER ePM1 60%(ISO 16890)
EC BRUSHLESS FAN
AIRFIX is designed to stop impurities in the air such as VIRUSES, BACTERIA, and ALLERGENS alike, however there are precautions that can be taken to optimi-ze the reduction percentage and the time required to make each environment healthy.
VIRUSES: to effectively eliminate viruses, the fan potentiometer must be positioned at minimum power, thus allowing UV-C lamps to neutralize pathogens of this type with less air changes.
The data indicated refer to laboratory tests carried out in an environment of 250 m³.
BACTERIA: bacterial loads are effectively eliminated by UV-C lamps and partially retained in the fil-ters present in the unit. To optimize times and effectiveness it is recommended to placethe fan potentiometer halfway.
POLLEN AND ALLERGENS: These organisms with a larger volume than the previous categories of pathogens are effectively trapped in the unit’s certified filters. The power of the fan doesn’t compro-mise effectiveness, therefore to optimize the cleaning time of the environment it is possible to use the fan at maximum power, thus favoring more air changes in a shorter time.
VIRUSes
UV-C
FILTERS
bacteria pollen / allergens
1h
1h
1h
20%
40%
60%80%
100%
20%
40%
60%80%
100%
20%
40%
60%80%
100%
effectiveness
% killing
CONFIGURATED WITH ACTIVE MODULE
HEPA 13 CERTIFICATED FILTER
(ISO 29463-3:2019)
ePM1 60% CERTIFICATED FILTER
(ISO 16890)
EC BRUSHLESS FAN
ACTIVE MODULE
55%
63%
70%
72%99%
UV-C LAMPS Catalyst alloy Oxidrile Radicals decomposition of bacteria and pollutants
decomposition result:carbon dioxideHydrogen peroxide
The technology knowed as photocatalytic oxidation was developed and used in the aero-space field for sanitation for space exploration envirorment, where the first prerogative is quality and healthiness of the air. This oxidizing action reproduces a natural process called photocatalysis, which thanks to the combined action UV rays from the sun, humidity in the air and some noble metals present in nature, destroys most of the toxic and polluting sub-stances.
The active sanitation module exploits the combined action of the rays of a special UV lamp with a metal alloy catalyst structure, mainly composed of TiO (titanium dioxide) and other noble metals in smaller quantities. Metals in contact with UV rays set off to the photocatalytic reaction, producing hydroxyl radicals and minimal quantities of hydrogen peroxide.The flow of air that invests the active element ensures the diffusion into the environment of the radicals produced, which attack and eliminate pathogens and impurities in the air.
This photochemical reaction therefore allows to eliminate pollutants with a natural active components, so viruses and molds, thanks to the hydrogen peroxide (hydrogen peroxide), generated by the photocatalytic reaction in minimal quantities (max. 0.02 PPM) has a very high efficacy in the destruction of the microbial charge, in the air and on surfaces both.
ACTIVE SANITATION SKILLS- CONTINUOUS SANITIZATION able to reduce the risk of contamination and exposure 24 / 24h- KILLING OF GERMS, BACTERIA AND VIRUSES, which proliferate, causing the spread of diseases and allergies-SENSITIVELY REDUCED ODORS-REDUCTION OF HARMFUL MICROPARTICLES present in the air, including ultra thin particles.-REDUCTION OF DUST CLUSTERS-BETTER AIR QUALITY IN GENERAL-
REDUCTION OF BACTERIA, MOLD AND VIRUSES
ODORS REDUCTION
REACTION MODULE
HIGH INTENSITY UV LAMP
METAL ALLOY
CATALYTIC STRUCTURE
smoke
kitchen
Animals
Chemical Agents
Effectiveness proved by laboratory testsat the surgical department
and morphological sciencesUNIMORE University
of Modena and Reggio Emiliaand by the analysis laboratory TECNAL S.r.l.
Plenum (Don’t cover)
Active Module (in Active version unit)
EC Fan
Fan Power knob
UVC LAMPS OR ACTIVE MODULE ON/OFF
On/Off UV-C lamps
HEPA13/14 Filterextractable
ePM1 Filterextractable
Remove the front panel to filter maintenance
Coarse Pre-filter
Suction inlet (Don’t cover)
The Filters working fine
The FilterePM1 need
maintenance
The Filter HEPA 13/14
need maintenance
Filters Status Led