Alfa Laval TK20Gasketed plate-and-frame heat exchanger
.
ApplicationThe Alfa Laval industrial semi welded line of plate heatexchangers is used for efficient heating and cooling ofaggressive media, including heat recovery, condensation andevaporation in refrigeration installations.
Benefits• Alfa Laval has global presence• Alfa Laval has global service organization• Part of a large portofolio of heat transfer products• High serviceability - Possible to open the PHE for
inspection and cleaning• Compact design• Flexible configuration - Heat transfer area can be modified• Leakage-proof design of the welded channels with
minimum gasket contact
DesignThe semi-welded plate heat exchanger consists of a packageof cassettes, each cassette consists of two welded corrugatedmetal plates with portholes for the passage of the two fluidsbetween which heat transfer will take place. Every cassetteis fitted with gaskets, which seal the channels and direct thefluids.
The number of plates is determined by the flow rates, physicalproperties of the fluids, pressure drops and temperatureprogram. The plate corrugations promote fluid turbulence andsupport the plates against differential pressure.
The materials of gaskets are selected for safe use dependingon media type and temperature. The attachment of thegaskets is glue-free, which makes them easy to replace evenwith the plates still hanging in the frame.
The carrying bar and guiding bar are fixed to the stationaryframe plate and the supporting column. The pressure plateand plate package is movable along the upper carrying barand located by the lower guiding bar. Connections are locatedin the frame plate. Depending on the application, connectionscan also be located in the pressure plate.
Working principleChannels are formed between the plates and the corner portsare arranged so that the two media flow through alternatechannels. The heat is transferred through the plates betweenthe channels. Complete counter-current or co-current flow,depending on the application, is created for highest possibleefficiency. The corrugation of the plates provides the passagebetween the plates, supports each plate against the adjacentone and enhances the turbulence, resulting in efficient heattransfer.
Flow principle of a plate heat exchanger.
STANDARD MATERIALSFrame plateMild steel, epoxy painted
ConnectionsMetal lined: Stainless steel, Titanium, and Alloy 254 (SMO)
PlatesStainless steel, Titanium, and Alloy 254 (SMO)
GasketsField gaskets: Nitrile, EPDMRing gaskets: Nitrile, EPDM, Chloroprene, FEPMAL
For refrigeration: Gasket design temperature range-45ºC to +160ºC (-50°F to +320°F)
Other grades and materials available upon request.
TECHNICAL DATAStandard design pressure (g)
Frame type Pressure vessel code Design pressureFG pvcALS™ 1.6 MPa at 50°CFG PED 1.6 MPa at 50°CFD pvcALS™ 2.5 MPa at 150°CFD PED 2.5 MPa at 150°CFD ASME 300 psi at 302°FFX PED 6.3 MPa at 150°CFX ASME 900 psi at 302°F
Design temperatureDetermined by gasket material.
Plate typesTK20-BW
.
Cross section of a semi-welded plate heat exchanger
Maximum standard heat transfer surface260 m2 (2790 sq.ft)Extended non-standard design available on request.
Maximum standard liquid flow rates0.2 m3/s
Connection sizeDN200 / DN150 / NPS 8 / NPS 6 / 200A
Connection standard
FG pvcALS™ EN 1092-1 PN161), ASME B16.5 Class 150, JIS B2220 16KFG PED EN 1092-1 PN161), ASME B16.5 Class 150FD pvcALS™ EN 1092-1 PN252), ASME B16.5 Class 3003), JIS B2220 20KFD PED EN 1092-1 PN252), ASME B16.5 Class 3003)
FD ASME ASME B16.5 Class 3003)
FX PED EN 1092-1 PN16 DN2004), EN 1092-1 PN25 DN2004),ASME B16.5 Class 150 NPS 84),EN 1092-1 PN63 DN1505), ASME B16.5 Class 300 NPS 65)
FX ASME ASME B16.5 Class 150 NPS 84),ASME B16.5 Class 300 NPS 65)
Notes
Standard EN 1092-1 corresponds to GOST 12815-80 and GB/T 9115.1) EN 1092-1 PN10 alternative standard gasketed channel only.2) EN 1092-1 PN16 alternative standard gasketed channel only.3) ASME B16.5 Class 150 alternative standard gasketed channel only.4) To be used for the gasketed channel only.5) To be used for the welded channel only.
Particulars required for quotationTo receive a quotation for plate heat exchangers that meetyour requirements, please provide Alfa Laval representativeswith:
• Flow rates or heat load• Temperature program• Physical properties of liquids in question (if not water)• Design pressure and design temperature• Maximum permitted pressure drop
S4 S1
S2S3
H 1179
(46.
42)
h
363 (14.29) 905 - 3355 (35.63 - 132.09)
W
Measurements mm (inch)
Type H W hTK20-FG 1525 (60.04) 740(29.13) 301 (11.85)TK20-FD 1525 (60.04) 785 (30.91) 301 (11.85)TK20-FX 1545 (60.04) 790 (31.10) 301 (11.85)The number of tightening bolts may vary depending on type.
.
PCT00204EN 1502 Alfa Laval reserves the right to change specifications without prior notification.
How to contact Alfa LavalUp-to-date AlfaLaval contact details forall countries are always available on ourwebsite on www.alfalaval.com
Benefits• Heavy duty design with high corrosion
resistance• Easily cleanable industrial power fins• Reliable performance• Easy installation & maintenance. • Reduced transport cost• Energy efficient - low total cost of
ownership.• Two-year product guarantee.
BDP 6 B C 8-185 X 6 7.5 D – options
Options
Fan speed connection (D=delta, Y=star)
Nominal installed fan motor power (kW)
Number of fan motor poles (6-8)
Fan diameter (X=1250 mm)
Model size
HT coil dimension (B, C)
LT coil dimension (B, C)
Number of fans (2-8)
AlfaBlue Power radiator
Code description
L W H weight Model fans mm mm mm kg
BDP 2*/8-159 2 3555 2330 1060 1100
BDP 3*/8-159 3 5145 2330 1060 1500
BDP 4*/8-159 4 6735 2330 1060 2100
BDP 5*/8-159 5 8325 2330 1060 2600
BDP 6*/8-159 6 9915 2330 1060 3200
BDP 7*/8-159 7 11505 2330 1060 3700
BDP 8*/8-159 8 13095 2330 1060 4200
BDP 2*/8-185 2 4075 2330 1060 1300
BDP 3*/8-185 3 5925 2330 1060 1900
BDP 4*/8-185 4 7775 2330 1060 2400
BDP 5*/8-185 5 9625 2330 1060 3000
BDP 6*/8-185 6 11475 2330 1060 3600
BDP 7*/8-185 7 13325 2330 1060 4300
BDP 2*/8-200 2 4375 2330 1060 1300
BDP 3*/8-200 3 6375 2330 1060 1900
BDP 4*/8-200 4 8375 2330 1060 2600
BDP 5*/8-200 5 10375 2330 1060 3200
BDP 6*/8-200 6 12375 2330 1060 4000
BDP 2*/8-222 2 4815 2330 1060 1450
BDP 3*/8-222 3 7035 2330 1060 2100
BDP 4*/8-222 4 9255 2330 1060 2900
BDP 5*/8-222 5 11475 2330 1060 3500
BDP 6*/8-222 6 13695 2330 1060 4400
Options • Larger fin spacings for dirty/dusty operating conditions• Stainless steel tubes (Aisi 304 or 316L)• Multi-Circuiting• Sandwiched coils (HT + LT)• Coil corrosion protection – Coil coating (Al-precoated or painted after production) – Cu fins – Fins seawater resistent aluminium alloy 57S/5052• Fan plate hot dip galvanized• Fan blade materials – Aluminium – Galvanized steel – Fiber glass• Coil protection grid• Handrail kit, ladder & steel support structure (H = 2 to 6 m)• Vibration dampers• Electrical options – Isolating switch – Motors wired to a common terminal box – Switchboard (IP55) – EMC approval – Fan step control – Fan speed control – Frequency control – Special fan motors (on request)
All models: connections on the same side
To reduce transport cost, AlfaBlue Power units are usually shipped in vertical position. An additional 50% reduction may be achieved by combining two units during transportation.
Visit www.alfalaval.com for more information or contact
(IPC) Industrial Power Cooling LtdOrchard Cottage, Barston Lane, Barston, Solihull, B92 0JP, England www.ipcuk.com, [email protected] Telephone: 00 44 (0) 845 873 9916, fax: 00 44 (0) 845 873 9924
ERC00272EN 1112 Alfa Laval reserves the right to change specification without prior notification.