Download - An introduction on design patterns about BIPV for architects 建筑师视角下的 光伏建筑设计模式 Xu Shen/ 徐 燊
An introduction on design patterns about BIPV for architects
建筑师视角下的
光伏建筑设计模式
Xu Shen/ 徐 燊
An introduction on design patterns about BIPV for architects
建筑师视角下的
光伏建筑设计模式
Xu Shen/ 徐 燊
Multiple discipline impact on the development of BIPVMultiple discipline impact on the development of BIPV
PV is a design element of a building and thus, should be considered in the very early stages of building concept design planning.
PV is a design element of a building and thus, should be considered in the very early stages of building concept design planning.
PV typologies and their characterPV typologies and their character
Cells material
Module efficiency
Area need for 1KWp
Costs
Efficiency impacted
by temperatur
e
Sensitivity with solar
direct radiation
Mono-crystalline
silicon12%~15% 7 m2~9m2
High Great HighPoly-
crystalline silicon
11%~14% 7.5 m2~10 m2
Amorphous silicon
6%~8% 14 m2~20 m2
Low Small LowCIS
material8%~12% 9 m2~11 m2
CdTe material 7%~10% 12 m2~17 m2
PV color
The PV color are originally grey, blue-black or black. Nowadays, the colors green, gold, brown and violet can be produces by anti-reflective coating. The various colors is desirable to architects to create novel appearance and architectural expression.
PV color
The PV color are originally grey, blue-black or black. Nowadays, the colors green, gold, brown and violet can be produces by anti-reflective coating. The various colors is desirable to architects to create novel appearance and architectural expression.
Shadow impacts Shadowing of the modules is an
important consideration, especially when they are connected together in a string. If a module lies in the shadow of an object, no more current is generated in this module. Instead, it uses the current from other modules. In general, shading should be avoided as much as possible.
Shadow impacts Shadowing of the modules is an
important consideration, especially when they are connected together in a string. If a module lies in the shadow of an object, no more current is generated in this module. Instead, it uses the current from other modules. In general, shading should be avoided as much as possible.
Holistic form patterns of BIPV
Vertical façade
Sloping surface
Stepped mode
Holistic form patterns of BIPV
Vertical façade
Sloping surface
Stepped mode
Detailed design patterns of BIPV
Sloping roof
Flat roof
Curved roof
Atrium
Vertical façade
Vertical saw-toothed façade
Horizontal saw-toothed façade
Sunshade
Detailed design patterns of BIPV
Sloping roof
Flat roof
Curved roof
Atrium
Vertical façade
Vertical saw-toothed façade
Horizontal saw-toothed façade
Sunshade
Thank youThank you