HIGHLIGHTING FEATURES:�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Self-contained microprocessor based multi channelalarm annunciator unit
16 contact operated on/off alarmMultiple LEDs for visual alarm indication for eachwindow provide redundancyAlarm channels activated by normally open ornormally closed contact
Compact Design, highly reliable, allowsincorporation of custom changes with ease
Meets IEC 60255-5 RatingsAlarm Display windows selection availableVoltage type selection option available (AC or DC)Long life super bright multiple LEDs installed ineach window to ensure long maintenance free periodInput voltage selection range availableLamp test input availableAn output to actuate audible alarm (buzzer / Hooter)Alarm acknowledge input
Highly reliable switch mode power supply to
accommodate wide range ofAC or DC voltage.
Composed of three modules (Annunciation, I/O
module, power module) mounted on a single PCB
�
�
Protection:
Accessories:
�
�
�
Over voltage
Mounting screwsFloor Stand
INTRODUCTION:EL AM-101 is highly reliable microprocessor basedannunciator unit that is used in Power Plants, Grid Station,Substations & industrial Panels for providing supervisorycontrolThe general purpose is to provide supervision in theprocess occurring in IPPs, Grid Stations, industries & togenerate an alarm for any abnormal condition byilluminating respecting LED based window, commonaudible alarm by using any audible device (bell, hooter,siren)
OPERATION CRITERIA:The annunciation event is indicated by the input signalchanging from low to high voltage level. Each event has adedicated display Window with user Defined text messagewritten on it. AM-101can be modified to handle differentinput signal voltage levels.Contrary to conventionalannunciator AM-101 is equipped in For illuminating thedisplay windows the light bulbs have been replaced bylonger life super bright LEDs, thus practically eliminatingthe need of frequent bulb replacement.
In order to distinguish between noise signals &fault signals, it takes 200m sec to annunciate fault window& actuate the audible alarm.
NOTE:
��������������� �������
��������������� �������
�������������������
����������������
������������
��������
����������������������
��������
����������������������
��������
����������������������
����������������������
���������������������
������������
������������
���!������
TS101TS101EL AM-101EL AM-101
�
�
�
�
�
�
�
�
Number of fault windows selectionOperating Voltage selectionCasing SelectionLEDs color selectionFault window initiation on pickup or dropoutFault window flash rate selectionFault window input voltage selectionHooter silence independent input selection
For all available optional features please seethe “Specifications” section on next page.
OPTIONAL PARAMETERS
Utility & Communications
Manufacturing:
�
�
�
�
�
�
�
Power HousesPower SubstationsProtection and Control SystemsMicrowave Relay SitesSwitchgears control
Control signaling of the processAlarm Systems
Commercial:
�
�
�
�
Alarm SystemsSolar Systems control signalingUninterruptible power SystemsDC Control Systems
APPLICATIONS
A Product of ELABSEP SOL (Pvt) Ltd
ELECTRICAL POWER ENGINEERING SOLUTIONS
����������������
������������
��������
����������������������
��������������� �������
���!������
����������������������
����������������������
������������
��������
����������������������
���������������������
������������
��������
����������������������
����
MOUNTING & DIMENSIONS
��������������� �������
��������������� �������
�������������������
����������������
������������
��������
��������
��������
����������������������
������������
������������
���!������
150
110
10 155
130
FRONT VEIW SIDE VEIW TOP VIEW
EL AM-101EL AM-101
A Product of ELABS
SPECIFICATIONS
Power Supply:
Input Voltage/ Frequency:
Display Windows:
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Single Phase:
Output Power:
Numbers:
Lighting devices:
Flash Rate:
100 Vac to 275 Vac @ 50Hz / 60Hz (STM)100 Vdc to 375 Vdc (STM)Customized (SPMs)
25 Watts (STM)
8 or 12 (STM)4 or 6 (SPMs)
LEDs of amber color (STM)LEDs of red, yellow, green, blue and white
(SPMs)3 different color LEDs in a single window, thecolor selection can be done through field (SPMs)
40 flashes per minute (STM)Variable flash rate where flash frequency changesin case of fault persistence and fast events.(SPMs)
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Pickup:
Temperature:
Relative Humidity:
Power Consumption:
Input Voltage:
Input Voltage:
Inputs change from Low to high (STM)
Inputs change from High to low (SPMs)
-100C to 550C (STM)
100% (STM)
10 Watts approx (STM)
Universal type input AC or DC (STM)
100 Vac to 275 Vac or 100 Vdc to 375 Vdc (SPMs)
137mm x 97 mm independent of no. of windows
Environmental:
Fault Signals:
Panel Cutout:
�
�
�
STM Standard ModelSPMs Special Models
THEORY OF OPERATION:
Due to the flexible architecture, all the standard sequencescan be incorporated. The basic function of anAM-101 is todetect faults or events at its inputs, (terminated outside thecase) and indicate that, by flashing pertinent windows,followed byACKNOWLEDGE, and RESET etc
Once an input is energized, the lights on the relevantwindow start flashing and the hooter comes on. Theduration of flash rate is sufficient for the inscription ofthe function to be read easilyOn pressing the ACKNOWLEDGE button, theindication flashing will be stopped, and light on thefault window will be kept ON continuously. If faultsignal is removed before the RESET push button ispressed, the window starts flashing again.But in a special model under above scenario the flashrate will be half of the initial flash rate, to indicate theremoval of fault
�
�
�
�
�
�
The RESET is then pressed to extinguish the windowLEDsIn case of persistence of fault, the window shallcontinue to stay lit even when the reset button ispressed.If another fault is energized before having the previousevent cleared the scheme re-functions the same way asdescribed above.The LAMP TEST push button is pressed (whenrequired) to test all window LEDs by lighting themsimultaneously
�Others:�
�
�
Independent hooter reset input available other thanavailable in STMACKNOWLEDGE, RESET and LAMP TEST inputsavailable in STM, a separate independent input forhooter silence operation is available in SPMs.Built-in memory to display the order of occurrence ofevents (SPMs).
EP SOL (Pvt) Ltd
ELECTRICAL POWER ENGINEERING SOLUTIONS
EL AM-101EL AM-101
�� For other NON - LISTED/Optional requirement, please contact factory.
8-Windows 12-Windows 16-Windows Size
Single Window
Overall size
Dimensions:
71-B Garden Block New Garden Town Lahore
TEL:+92 42 588 4232 FAX-+92 42 586 8145Email: URL: [email protected]
EP SOL (Pvt) Ltd
ELECTRICAL POWER ENGINEERING SOLUTIONS
MODEL DEFINITION (ORDERING) :
AM 101 - - - -- - -* * ** ** ** * **
Base Unit / Model
A
D
1
2
3
N
L
H
0
1
2
Input Volt Level to power up fault windows A
B
C
1
2
Input Frequency
Input Volts
No. of Annunciation windows
Input Volt Level to power up annunciator
Control Arrangement
Special Model00
01(Consult factory for listed special
models / options)
DC Operated
50Hz
60Hz
AC Voltage
DC Voltage
8- Windows
12- Windows16- WindowsUser Defined
24V DC
48V DC
Universal (AC / DC )
24V DC
48V DC
Control Facility on TB
Control Facility on Front
Standard model
Customized order
Universal (AC / DC)
E - LABS