  • TOP OF HARDSTANDTOP OF EXISTING SURFACE

    TOP OF KERB FACE.

    NOMINAL SHORELINE, REFER NOTES.

    530 790 600

    210

    2070 PREFERRED

    1540 MINIMUM

    300

    600 BUS STOP SIGNAGE, REFER NOTES.

    1200

    MIN

    .FU

    TURE

    OR

    EXIS

    TING

    ACCE

    SS P

    ATH

    (WID

    TH V

    ARIE

    S)

    2070

    MIN

    IMUM

    REQ

    UIRE

    DHA

    RDST

    AND

    SIZE

    MAY

    VAR

    Y DE

    PEND

    ING

    ON E

    XIST

    ING

    SITE

    CON

    DITI

    ONS

    150

    WARNING TGSI'S TO BE INSTALLED ATALL STOPS, REFER NOTES.

    DIRECTIONAL TGSI'S TO BE INSTALLEDAND TO EXTEND TO SHORELINE, REFERNOTES.

    MANDATORY MINIMUM CONCRETEHARDSTAND BOARDING POINT AREASHOWN CROSS HATCHED, REFERNOTES.

    600

    125 M

    IN.

    TOP OF HARDSTAND TO BE FLUSH WITHTOP OF ADJACENT SURFACE.

    MESH PLACED CENTRALLY.

    125 M

    IN.

    TOP OF HARDSTANDTOP OF EXISTING SURFACE

    TOP OF HARDSTAND TO BE FLUSH WITHTOP OF EXISTING SURFACE/ KERB.

    ISOLATION JOINT.

    ROADWAY

    150

    A

    2070 MINIMUM

    B

    BARRIER KERB.

    EXISTING OR FUTURE ACCESSPATHWAY LOCATION, CONFIRMON SITE.

    CL

    300TO SIGN FACE

    150

    TGSI

    50mm SAND BUNDING LAYER.

    50mm SAND BUNDING LAYER.

    MESH PLACED CENTRALLY.

    ISOLATION JOINT.

    BACK OF KERB.

    A

    ISOLATION JOINT TO LOCALGOVERNMENT REQUIREMENTS.

    B

    TOP OF KERB FACE.

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - MINIMUM BOARDING POINT - WITH EXISTING KERB

    ADRG 5-0011

    1-

    SITE LAYOUT PLAN1:50@A3

    A-

    SECTION A1:50@A3

    B-

    SECTION B1:50@A3

    - JULY 2013

    TOP OF HARDSTANDTOP OF EXISTING SURFACE

    TOP OF KERB FACE.

    NOMINAL SHORELINE, REFER NOTES.

    530 790 600

    210

    2070 PREFERRED

    1540 MINIMUM

    300

    600 BUS STOP SIGNAGE, REFER NOTES.

    1200

    MIN

    .FU

    TURE

    OR

    EXIS

    TING

    ACCE

    SS P

    ATH

    (WID

    TH V

    ARIE

    S)

    2070

    MIN

    IMUM

    REQ

    UIRE

    DHA

    RDST

    AND

    SIZE

    MAY

    VAR

    Y DE

    PEND

    ING

    ON E

    XIST

    ING

    SITE

    CON

    DITI

    ONS

    150

    WARNING TGSI'S TO BE INSTALLED ATALL STOPS, REFER NOTES.

    DIRECTIONAL TGSI'S TO BE INSTALLEDAND TO EXTEND TO SHORELINE, REFERNOTES.

    MANDATORY MINIMUM CONCRETEHARDSTAND BOARDING POINT AREASHOWN CROSS HATCHED, REFERNOTES.

    600

    125 M

    IN.

    TOP OF HARDSTAND TO BE FLUSH WITHTOP OF ADJACENT SURFACE.

    MESH PLACED CENTRALLY.

    125 M

    IN.

    TOP OF HARDSTANDTOP OF EXISTING SURFACE

    TOP OF HARDSTAND TO BE FLUSH WITHTOP OF EXISTING SURFACE/ KERB.

    ISOLATION JOINT.

    ROADWAY

    150

    A

    2070 MINIMUM

    B

    BARRIER KERB.

    EXISTING OR FUTURE ACCESSPATHWAY LOCATION, CONFIRMON SITE.

    CL

    300TO SIGN FACE

    150

    TGSI

    50mm SAND BUNDING LAYER.

    50mm SAND BUNDING LAYER.

    MESH PLACED CENTRALLY.

    ISOLATION JOINT.

    BACK OF KERB.

    A

    ISOLATION JOINT TO LOCALGOVERNMENT REQUIREMENTS.

    B

    TOP OF KERB FACE.

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - MINIMUM BOARDING POINT - WITH EXISTING KERB

    ADRG 5-0011

    1-

    SITE LAYOUT PLAN1:50@A3

    A-

    SECTION A1:50@A3

    B-

    SECTION B1:50@A3

    - JULY 2013

  • TOP OF KERB FACE FOR NEW150MMHIGH KERB ALIGNED TO EDGE OFEXISTING TRAFFIC LANE.

    NOMINAL SHORELINE.

    530 790 600

    2500 PREFERRED

    1540 MINIMUM

    300

    600 BUS STOP SIGNAGE, REFER NOTES.

    2070

    MIN

    IMUM

    150

    WARNING TGSI'S TO BE INSTALLED ATALL STOPS, REFER NOTES.

    DIRECTIONAL TGSI'S TO BE INSTALLEDAND EXTEND TO SHORELINE, REFERNOTES.

    MANDATORY MINIMUM CONCRETEHARDSTAND BOARDING POINT AREASHOWN CROSS HATCHED, REFERNOTES.

    600

    1200

    MIN

    .

    1200 1200

    FALL 1:8FALL 1:8

    FALL 1:8

    NOMINAL EDGE OF EXISTING TRAFFICLANE.

    TOP OF EXISTING SURFACETOP OF HARDSTAND

    TOP OF EXISTING SURFACETOP OF HARDSTAND

    TOP OF RAISED HARDSTAND/KERB.MESH PLACED CENTRALLY.

    ROADWAY

    150

    2070 MINIMUM

    1200

    1200

    125 M

    IN.

    TOP OF RAISED HARDSTAND.MESH PLACED CENTRALLY.

    125 M

    IN.

    150

    FALL 1:8 FALL 1:8

    FALL 1:8

    ROAD EDGE GUIDE POST TORELEVANT AUTHORITYREQUIREMENTS (AS REQUIRED) 2000

    C

    D

    4900

    3270

    CL

    300TO SIGN FACE

    1170

    150

    ISOLATION JOINT TO LOCALGOVERNMENT REQUIREMENTS.

    1200

    MIN

    .FU

    TURE

    OR

    EXIS

    TING

    ACCE

    SS P

    ATH

    (WID

    TH V

    ARIE

    S)

    EXISTING OR FUTURE ACCESSPATHWAY LOCATION, CONFIRMON SITE.

    * *

    *

    *

    * *

    *

    C

    DTGSI

    (1520 MAX.)

    (MAX. 1520) (MAX. 1520)

    (MAX. 1520)

    TOP OF KERB FACE.

    1200

    210

    *

    430

    EXTENSION TO HARDSTAND FORSIGNAGE.

    KERB EDGE DOWNTURNTO FORM BARRIER KERB.

    (1520 MAX.) (1520 MAX.)

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - MINIMUM BOARDING POINT - WITHOUT EXISTING KERB

    ADRG 5-0012

    1-

    SITE LAYOUT PLAN1:50@A3

    C-

    SECTION C1:50@A3

    D-

    SECTION D1:50@A3

    - JULY 2013

    TOP OF KERB FACE FOR NEW150MMHIGH KERB ALIGNED TO EDGE OFEXISTING TRAFFIC LANE.

    NOMINAL SHORELINE.

    530 790 600

    2500 PREFERRED

    1540 MINIMUM

    300

    600 BUS STOP SIGNAGE, REFER NOTES.

    2070

    MIN

    IMUM

    150

    WARNING TGSI'S TO BE INSTALLED ATALL STOPS, REFER NOTES.

    DIRECTIONAL TGSI'S TO BE INSTALLEDAND EXTEND TO SHORELINE, REFERNOTES.

    MANDATORY MINIMUM CONCRETEHARDSTAND BOARDING POINT AREASHOWN CROSS HATCHED, REFERNOTES.

    600

    1200

    MIN

    .

    1200 1200

    FALL 1:8FALL 1:8

    FALL 1:8

    NOMINAL EDGE OF EXISTING TRAFFICLANE.

    TOP OF EXISTING SURFACETOP OF HARDSTAND

    TOP OF EXISTING SURFACETOP OF HARDSTAND

    TOP OF RAISED HARDSTAND/KERB.MESH PLACED CENTRALLY.

    ROADWAY

    150

    2070 MINIMUM

    1200

    1200

    125 M

    IN.

    TOP OF RAISED HARDSTAND.MESH PLACED CENTRALLY.

    125 M

    IN.

    150

    FALL 1:8 FALL 1:8

    FALL 1:8

    ROAD EDGE GUIDE POST TORELEVANT AUTHORITYREQUIREMENTS (AS REQUIRED) 2000

    C

    D

    4900

    3270

    CL

    300TO SIGN FACE

    1170

    150

    ISOLATION JOINT TO LOCALGOVERNMENT REQUIREMENTS.

    1200

    MIN

    .FU

    TURE

    OR

    EXIS

    TING

    ACCE

    SS P

    ATH

    (WID

    TH V

    ARIE

    S)

    EXISTING OR FUTURE ACCESSPATHWAY LOCATION, CONFIRMON SITE.

    * *

    *

    *

    * *

    *

    C

    DTGSI

    (1520 MAX.)

    (MAX. 1520) (MAX. 1520)

    (MAX. 1520)

    TOP OF KERB FACE.

    1200

    210

    *

    430

    EXTENSION TO HARDSTAND FORSIGNAGE.

    KERB EDGE DOWNTURNTO FORM BARRIER KERB.

    (1520 MAX.) (1520 MAX.)

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - MINIMUM BOARDING POINT - WITHOUT EXISTING KERB

    ADRG 5-0012

    1-

    SITE LAYOUT PLAN1:50@A3

    C-

    SECTION C1:50@A3

    D-

    SECTION D1:50@A3

    - JULY 2013

  • TOP OF KERB FACE.

    NOMINAL SHORELINE.

    2760 790

    1540 MIN.

    300

    600 WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    600

    BIN, REFER NOTES.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    4300

    SEAT, REFER NOTES.

    25m PREFERRED 10m MINIMUM

    210

    4200

    HARDSTAND SIZE MAY VARY DEPENDINGON EXISTING SITE CONDITIONS.

    CL

    CL

    600

    350

    300TO SIGN FACE

    DIRECTIONAL TGSI'S TO BE INSTALLED AND TO EXTEND SHORELINE,REFER NOTES.

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.LIGHT POLE (SITE SPECIFIC).

    2500 MIN.

    350

    ACCESS PATHWAY MINIMUM 1200MM(WIDTH VARIES).

    150

    HARDSTAND AREA CAN BE INCREASED TO MEETSITE SPECIFIC REQUIREMENTS.

    2500 CL

    *

    *

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE. 50

    0 MIN

    .

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    2070

    MIN

    IMUM

    500 M

    IN.

    2NO. 800x1300 PWD WAITING ZONES.

    *

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    1500

    BUS ZONE SIGNREFER MUTCDPART 11

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    25m PREFERRED 10m MINIMUM

    CL BUS STOP SIGN

    HARDSTAND

    DIRECTION OF TRAFFIC FLOW

    BUS ZONE

    LENGTH VARIES TO SUIT QUANTITY ANDTYPE OF BUSES USING STOP AND TYPE

    OF OPERATION

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - WITHOUT INDENTED BUS BAY

    ADRG 5-0013

    1-

    KEY PLAN1:500@A3

    2-

    SITE LAYOUT PLAN1:100@A3

    - JULY 2013

    TOP OF KERB FACE.

    NOMINAL SHORELINE.

    2760 790

    1540 MIN.

    300

    600 WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    600

    BIN, REFER NOTES.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    4300

    SEAT, REFER NOTES.

    25m PREFERRED 10m MINIMUM

    210

    4200

    HARDSTAND SIZE MAY VARY DEPENDINGON EXISTING SITE CONDITIONS.

    CL

    CL

    600

    350

    300TO SIGN FACE

    DIRECTIONAL TGSI'S TO BE INSTALLED AND TO EXTEND SHORELINE,REFER NOTES.

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.LIGHT POLE (SITE SPECIFIC).

    2500 MIN.

    350

    ACCESS PATHWAY MINIMUM 1200MM(WIDTH VARIES).

    150

    HARDSTAND AREA CAN BE INCREASED TO MEETSITE SPECIFIC REQUIREMENTS.

    2500 CL

    *

    *

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE. 50

    0 MIN

    .

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    2070

    MIN

    IMUM

    500 M

    IN.

    2NO. 800x1300 PWD WAITING ZONES.

    *

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    1500

    BUS ZONE SIGNREFER MUTCDPART 11

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    25m PREFERRED 10m MINIMUM

    CL BUS STOP SIGN

    HARDSTAND

    DIRECTION OF TRAFFIC FLOW

    BUS ZONE

    LENGTH VARIES TO SUIT QUANTITY ANDTYPE OF BUSES USING STOP AND TYPE

    OF OPERATION

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - WITHOUT INDENTED BUS BAY

    ADRG 5-0013

    1-

    KEY PLAN1:500@A3

    2-

    SITE LAYOUT PLAN1:100@A3

    - JULY 2013

    TOP OF KERB FACE.

    NOMINAL SHORELINE.

    2760 790

    1540 MIN.

    300

    600 WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    600

    BIN, REFER NOTES.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    4300

    SEAT, REFER NOTES.

    25m PREFERRED 10m MINIMUM

    210

    4200

    HARDSTAND SIZE MAY VARY DEPENDINGON EXISTING SITE CONDITIONS.

    CL

    CL

    600

    350

    300TO SIGN FACE

    DIRECTIONAL TGSI'S TO BE INSTALLED AND TO EXTEND SHORELINE,REFER NOTES.

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.LIGHT POLE (SITE SPECIFIC).

    2500 MIN.

    350

    ACCESS PATHWAY MINIMUM 1200MM(WIDTH VARIES).

    150

    HARDSTAND AREA CAN BE INCREASED TO MEETSITE SPECIFIC REQUIREMENTS.

    2500 CL

    *

    *

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE. 500 M

    IN.

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    2070

    MIN

    IMUM

    500 M

    IN.

    2NO. 800x1300 PWD WAITING ZONES.

    *

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    1500

    BUS ZONE SIGNREFER MUTCDPART 11

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    25m PREFERRED 10m MINIMUM

    CL BUS STOP SIGN

    HARDSTAND

    DIRECTION OF TRAFFIC FLOW

    BUS ZONE

    LENGTH VARIES TO SUIT QUANTITY ANDTYPE OF BUSES USING STOP AND TYPE

    OF OPERATION

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - WITHOUT INDENTED BUS BAY

    ADRG 5-0013

    1-

    KEY PLAN1:500@A3

    2-

    SITE LAYOUT PLAN1:100@A3

    - JULY 2013

  • TOP OF KERB FACE

    NOMINAL SHORELINE.

    300

    2070

    MIN

    IMUM

    WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    600

    BIN, REFER NOTES.

    210

    4200

    CL

    350

    TO SIGN FACE

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.LIGHT POLE (SITE SPECIFIC).

    350

    3000

    150

    HARDSTAND AREA CAN BE INCREASED TO MEETSITE SPECIFIC REQUIREMENTS.

    BUS BAY INDENT SETOUT REFER INSERTKEY DRAWING.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    DIRECTIONAL TGSI'S TO BE INSTALLED AND TO EXTEND SHORELINE,REFER NOTES.ACCESS PATHWAY MINIMUM 1200MM

    (WIDTH VARIES).*

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE.

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    300

    500 M

    IN.

    500 M

    IN.

    2760 790

    1540 MIN.

    4300

    600

    2500 MIN.

    *

    SEAT, REFER NOTES.

    HARDSTAND SIZE MAY VARY DEPENDINGON EXISTING SITE CONDITIONS.2NO. 800x1300 PWD WAITING ZONES.

    600

    *

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    1500

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    21m MINIMUM 15m MINIMUM

    CL BUS STOP SIGN

    HARDSTAND

    LENGTH VARIES TO SUIT QUANTITY AND TYPE OFBUSES USING STOP AND TYPE OF OPERATION

    1:5 KERB1:7 KERB

    DIRECTION OF TRAFFIC FLOW

    3m

    BUS ZONE

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - WITH INDENTED BUS BAY

    ADRG 5-0014

    1-

    KEY PLAN1:500@A3

    2-

    SITE LAYOUT PLAN1:100@A3

    - JULY 2013

    TOP OF KERB FACE

    NOMINAL SHORELINE.

    300

    2070

    MIN

    IMUM

    WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    600

    BIN, REFER NOTES.

    210

    4200

    CL

    350

    TO SIGN FACE

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.LIGHT POLE (SITE SPECIFIC).

    350

    3000

    150

    HARDSTAND AREA CAN BE INCREASED TO MEETSITE SPECIFIC REQUIREMENTS.

    BUS BAY INDENT SETOUT REFER INSERTKEY DRAWING.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    DIRECTIONAL TGSI'S TO BE INSTALLED AND TO EXTEND SHORELINE,REFER NOTES.ACCESS PATHWAY MINIMUM 1200MM

    (WIDTH VARIES).*

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE.

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    300

    500 M

    IN.

    500 M

    IN.

    2760 790

    1540 MIN.

    4300

    600

    2500 MIN.

    *

    SEAT, REFER NOTES.

    HARDSTAND SIZE MAY VARY DEPENDINGON EXISTING SITE CONDITIONS.2NO. 800x1300 PWD WAITING ZONES.

    600

    *

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    1500

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    21m MINIMUM 15m MINIMUM

    CL BUS STOP SIGN

    HARDSTAND

    LENGTH VARIES TO SUIT QUANTITY AND TYPE OFBUSES USING STOP AND TYPE OF OPERATION

    1:5 KERB1:7 KERB

    DIRECTION OF TRAFFIC FLOW

    3m

    BUS ZONE

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - WITH INDENTED BUS BAY

    ADRG 5-0014

    1-

    KEY PLAN1:500@A3

    2-

    SITE LAYOUT PLAN1:100@A3

    - JULY 2013

    TOP OF KERB FACE

    NOMINAL SHORELINE.

    300

    2070

    MIN

    IMUM

    WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    600

    BIN, REFER NOTES.

    210

    4200

    CL

    350

    TO SIGN FACE

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.LIGHT POLE (SITE SPECIFIC).

    350

    3000

    150

    HARDSTAND AREA CAN BE INCREASED TO MEETSITE SPECIFIC REQUIREMENTS.

    BUS BAY INDENT SETOUT REFER INSERTKEY DRAWING.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    DIRECTIONAL TGSI'S TO BE INSTALLED AND TO EXTEND SHORELINE,REFER NOTES.ACCESS PATHWAY MINIMUM 1200MM

    (WIDTH VARIES).*

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE.

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    300

    500 M

    IN.

    500 M

    IN.

    2760 790

    1540 MIN.

    4300

    600

    2500 MIN.

    *

    SEAT, REFER NOTES.

    HARDSTAND SIZE MAY VARY DEPENDINGON EXISTING SITE CONDITIONS.2NO. 800x1300 PWD WAITING ZONES.

    600

    *

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    1500

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    21m MINIMUM 15m MINIMUM

    CL BUS STOP SIGN

    HARDSTAND

    LENGTH VARIES TO SUIT QUANTITY AND TYPE OFBUSES USING STOP AND TYPE OF OPERATION

    1:5 KERB1:7 KERB

    DIRECTION OF TRAFFIC FLOW

    3m

    BUS ZONE

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - WITH INDENTED BUS BAY

    ADRG 5-0014

    1-

    KEY PLAN1:500@A3

    2-

    SITE LAYOUT PLAN1:100@A3

    - JULY 2013

  • NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    4200

    4300

    930

    4300

    900

    VARI

    ES

    4300

    1500

    1500

    1200

    MIN

    . (W

    IDTH

    VAR

    IES)

    1200

    MIN

    .

    2070

    1200

    MIN

    .

    1200

    MIN

    .

    SHORELINE

    TOP OF KERB FACE TOP OF KERB FACE

    TOP OF KERB FACE TOP OF KERB FACE

    3000

    SHORELINE

    SHORELINE

    3500

    4200

    2070

    2070

    4750

    1200 MIN.20

    70

    SHORELINE

    5500

    1200

    MIN

    .

    2070

    SHORELINE

    TOP OF KERB FACE

    2500

    1300

    500 M

    IN.

    500 M

    IN.

    500 M

    IN.

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - ACCESS EXAMPLES

    ADRG 5-0015

    1-

    CONSTRAINED SITE 1:100@A3

    2-

    HARDSTAND - MID/ FRONT FOOTPATH1:100@A3

    3-

    HARDSTAND - MID/BACK FOOTPATH1:100@A3

    4-

    HARDSTAND - SHARED ACCESS PATH BEHIND1:100@A3

    5-

    CONSTRAINED SITE 1:100@A3

    - JULY 2013

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    4200

    4300

    930

    4300

    900

    VARI

    ES

    4300

    1500

    1500

    1200

    MIN

    . (W

    IDTH

    VAR

    IES)

    1200

    MIN

    .

    2070

    1200

    MIN

    .

    1200

    MIN

    .

    SHORELINE

    TOP OF KERB FACE TOP OF KERB FACE

    TOP OF KERB FACE TOP OF KERB FACE

    3000

    SHORELINE

    SHORELINE

    3500

    4200

    2070

    2070

    4750

    1200 MIN.

    2070

    SHORELINE

    5500

    1200

    MIN

    .

    2070

    SHORELINE

    TOP OF KERB FACE

    2500

    1300

    500 M

    IN.

    500 M

    IN.

    500 M

    IN.

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - ACCESS EXAMPLES

    ADRG 5-0015

    1-

    CONSTRAINED SITE 1:100@A3

    2-

    HARDSTAND - MID/ FRONT FOOTPATH1:100@A3

    3-

    HARDSTAND - MID/BACK FOOTPATH1:100@A3

    4-

    HARDSTAND - SHARED ACCESS PATH BEHIND1:100@A3

    5-

    CONSTRAINED SITE 1:100@A3

    - JULY 2013

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    4200

    4300

    930

    4300

    900

    VARI

    ES

    4300

    1500

    1500

    1200

    MIN

    . (W

    IDTH

    VAR

    IES)

    1200

    MIN

    .

    2070

    1200

    MIN

    .

    1200

    MIN

    .

    SHORELINE

    TOP OF KERB FACE TOP OF KERB FACE

    TOP OF KERB FACE TOP OF KERB FACE

    3000

    SHORELINE

    SHORELINE

    3500

    4200

    2070

    2070

    4750

    1200 MIN.

    2070

    SHORELINE

    5500

    1200

    MIN

    .

    2070

    SHORELINE

    TOP OF KERB FACE

    2500

    1300

    500 M

    IN.

    500 M

    IN.

    500 M

    IN.

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERREGULAR STOP - SITE LAYOUT - ACCESS EXAMPLES

    ADRG 5-0015

    1-

    CONSTRAINED SITE 1:100@A3

    2-

    HARDSTAND - MID/ FRONT FOOTPATH1:100@A3

    3-

    HARDSTAND - MID/BACK FOOTPATH1:100@A3

    4-

    HARDSTAND - SHARED ACCESS PATH BEHIND1:100@A3

    5-

    CONSTRAINED SITE 1:100@A3

    - JULY 2013

  • TOP OF KERB FACE.

    NOMINAL SHORELINE.

    300

    600

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.207

    0 MIN

    IMUM

    WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    HARDSTAND AREA - LENGTH MAY VARY

    600

    BIN, REFER NOTES.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    8000

    INTERMEDIATE SHELTER.

    25m PREFFERED 10m MINIMUM

    210

    DIRECTIONAL TGSI'S TO BE INSTALLED AND EXTEND TO SHORELINE,REFER NOTES.

    MIN.

    HARDSTAND SIZE MAY VARY DEPENDING ON EXISTING SITECONDITIONS.

    CL

    CL

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    300TO SIGN FACE

    LIGHT POLE (SITE SPECIFIC).

    1200 MIN.12

    00 M

    IN.

    2070 MINIMUM

    EDGE OF SHELTER TO EDGE OF HARDSTAND.

    350

    350

    2NO. 800x1300 PWD WAITING ZONES.

    APPROX. 2m AREA TO BE KEPT CLEAR OF ALL INFRASTRUCTURE FORMAINTENANCE ACCESS TO LIGHTBOX/ ADVERTISING CABINET .

    2500

    150CL

    500

    ACCESS PATHWAY MINIMUM 1200MM(WIDTH VARIES).

    *

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE.

    4200

    6460 790 600

    1500

    1540 MIN. 2500 MIN.

    *

    *

    BUS ZONE SIGNREFER MUTCDPART 11

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON THETRANSLINK DRAWINGS. A LARGER HARDSTAND AREA IS PREFERRED AND ISDEPENDENT ON SITE SPECIFIC CONDITIONS.

    2 THE MANDATORY LONGITUDINAL AND CROSS FALL GRADIENT AT BOARDINGPOINT IS MAXIMUM 1:40 FALL ACROSS THE BOARDING POINT AREA (SHOWNHATCHED). ALL OTHER HARDSTAND AND ADJACENT AREAS TO THE BUS STOPSHALL MEET APPLICABLE STANDARDS IN RELATION TO THE ADJACENT SITECONDITIONS, AND TO PREFERABLY ACHIEVE A LONGITUDINAL AND CROSSFALL GRADIENT OF MAXIMUM 1:40 FALL.

    3 HARDSTANDS SHALL BE MINIMUM 125MM THICK BROOM FINISHED (FOR SLIPRESISTANCE) GRADE N25 CONCRETE SL72 MESH PLACED CENTRALLY, OR, ASREQUIRED BY THE RELEVANT STATUTORY AUTHORITY. FOR SLAB THICKENINGAT FURNITURE LOCATIONS, AND JOINT LAYOUT AND SPECIFICATIONS REFERTO LOCAL GOVERNMENT SPECIFIC REQUIREMENTS.

    4 A CLEAR HARDSTAND ACCESS SPACE OF 1200MM MINIMUM IS REQUIREDBETWEEN AND AROUND ALL BUS STOP INFRASTRUCTURE (1500MMDESIRABLE).

    ACCESS5 WHERE BUS STOPS ARE LOCATED ALONG BICYCLE ROUTES, SHARED ACCESS

    PATHS SHOULD BE APPLIED AS PER LOCAL GOVERNMENT REQUIREMENTS ORWITH REFERENCE TO RELEVANT GUIDELINE DIMENSIONS GIVEN IN THEAPPLICABLE STANDARDS, TMR GUIDELINES, AND AUSTROADS.

    6 CIRCULATION OF WHEELCHAIRS SHOULD BE CONSIDERED AT EACH BUS STOPBASED ON SITE SPECIFIC CONDITIONS AND TO ADDRESS COMPLIANCE WITHDSAPT. LINE-MARKING OF THE 2No. ALLOCATED SPACES (PWD WAITINGZONES) IS NOT REQUIRED.

    7 TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD PREFERABLY BEINSTALLED AS SHOWN ON THE TRANSLINK DRAWINGS. WHERE THERE IS APATHWAY ACCESSING A BUS STOP, DIRECTIONAL TGSI SHALL BE INSTALLEDFOR THE FULL WIDTH OF THE PATH OF TRAVEL OVER A MINIMUM 600MMDEPTH AND PERPENDICULAR TO THE DIRECTION OF TRAVEL WHENAPPROACHING. DIRECTIONAL TGSI SHALL BE USED ACROSS THE OPEN SPACEFROM THE ACCESS PATHWAY DIRECTIONAL TGSI TO THE BOARDING POINTWARNING TGSI. TGSI TO EXTEND TO THE SHORELINE - I.E. BUILDING LINE,WALL, A FENCE, A KERB, OR A GRASS VERGE WHERE APPLICABLE.

    8 THE COLOUR OF TGSI SHALL BE SELECTED BASED ON SITE SPECIFICREQUIREMENTS. INTEGRATED TGSI SHALL HAVE A MINIMUM COLOURCONTRAST OF 30% COMPARED TO THE AMOUNT OF LIGHT REFLECTED FROMTHE SURFACE OF THE ADJACENT PATH OF TRAVEL. FOR EXAMPLE; FOR ALIGHT CONCRETE COLOURED PATH OF TRAVEL, DARK COLOURED (E.G.BLACK) TGSI MAY BE APPROPRIATE. FOR A BLACK BITUMEN PATH OF TRAVELLIGHT COLOURED (E.G. WHITE OR YELLOW) TGSI MAY BE APPROPRIATE. THISCONTRAST MUST BE MAINTAINED IN BOTH WET AND DRY CONDITIONS.

    SHELTER9 FOR OPTIONS OF SHELTER TYPES FOR INTERMEDIATE AND PREMIUM STOPS

    REFER TO TRANSLINK DRAWINGS. WHERE A SHELTER ABUTS A CONTINUOUSACCESSIBLE PATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRASTAGAINST BACKGROUND (E.G. FLOORING).

    FURNITURE & SIGNAGE10 FOR DETAILS OF BUS STOP SIGNAGE (J-POLE/BLADE) AND FOOTING DETAILS

    REFER TO TRANSLINK SIGNAGE MANUAL.11 SETOUT OF BLADE SIGN (REFER TO THE PREMIUM STOP TRANSLINK

    DRAWING) IS POSITIONED AS SHOWN DUE TO BUS STOP OPERATIONS, ANDROAD SAFETY REQUIREMENTS AND IS NON-COMPLIANT WITH DSAPT. PLEASELIAISE WITH TRANSLINK FOR DETAILS ON THIS REQUIREMENT.

    12 BUS STOP SEAT SHOULD INCLUDE ANODISED ALUMINIUM BATTENS WITHARMRESTS ALONG THE SEAT. SEATS SHOULD BE BOLTED TO HARDSTANDAREA, AND MADE FROM EASILY MAINTAINED MATERIALS. SEATS TO BECOMPLIANT WITH DSAPT. WHERE A SEAT ABUTS A CONTINUOUS ACCESSIBLEPATH OF TRAVEL, ENSURE MINIMUM 30% LUMINANCE CONTRAST AGAINSTBACKGROUND (E.G. FLOORING).

    13 BUS STOP BIN SHOULD BE AN 80 LITRE CIRCULAR CONSTRUCTION (SMALLSLOT PERFORATIONS) WHICH CAN BE EASILY MAINTAINED. BIN SHOULDINCLUDE A GALVANISED STEEL LINER AND A BIRD-PROOF LID. WHERE BINABUTS A CONTINUOUS ACCESSIBLE PATH OF TRAVEL ENSURE MINIMUM 30%LUMINANCE CONTRAST AGAINST BACKGROUND (E.G. FLOORING). BIN TO BEMINIMUM 500MM SETBACK FROM ACCESS PATHWAY.

    ADDITIONAL REQUIREMENTS14 ALL BUS STOPS TO BE DSAPT COMPLIANT. FOR FURTHER GUIDANCE REFER

    TO THE RELEVANT STANDARDS, TRANSLINK GUIDANCE AND RELEVANT LOCALGOVERNMENT REQUIREMENTS.

    15 ALL BUS STOP COMPONENTS SHOULD BE POSITIONED IN CONSIDERATION OFRELEVANT ONSITE CONDITIONS WITH REFERENCE TO THE GUIDANCECONTAINED WITHIN THE PTIM, AND FOR ADDITIONAL REQUIREMENTS ANDDESIGN ALTERNATIVES REFER TO THE COMPONENTS TABLE CONTAINED INTHE PTIM.

    16 REFER TO PTIM GLOSSARY FOR DEFINITIONS OF TERMS AND PTIMABBREVIATIONS FOR DEFINITIONS OF ACRONYMS.

    17 ALL DRAWING DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.

    * DIMENSION TO BE CONFIRMED ON SITE IN RELATION TO SITE CONDITIONS.

    25m PREFERRED 10m MINIMUM

    CL BUS STOP SIGN

    DIRECTION OF TRAFFIC FLOW

    HARDSTAND& EXTENSION

    BUS ZONE

    LENGTH VARIES TO SUIT QUANTITY ANDTYPE OF BUSES USING STOP AND TYPE

    OF OPERATION

    PTIM, BUS STOP INFRASTRUCTURE CHAPTERINTERMEDIATE STOP - SITE LAYOUT - WITHOUT INDENTED BUS BAY

    ADRG 5-0021

    1-

    KEY PLAN1:500@A3

    2-

    SITE LAYOUT PLAN1:100@A3

    - JULY 2013

    TOP OF KERB FACE.

    NOMINAL SHORELINE.

    300

    600

    SETOUT OF BUS STOP SIGNAGE, REFER NOTES.207

    0 MIN

    IMUM

    WARNING TGSI'S TO BE INSTALLED AT ALL STOPS, REFER NOTES.

    MANDATORY MINIMUM CONCRETE HARDSTAND BOARDING POINTAREA SHOWN DIAGONAL HATCHED, REFER NOTES.

    HARDSTAND AREA - LENGTH MAY VARY

    600

    BIN, REFER NOTES.

    YELLOW BUS STOP MARKINGS IF REQUIRED, AS PER REGULATIONS

    8000

    INTERMEDIATE SHELTER.

    25m PREFFERED 10m MINIMUM

    210

    DIRECTIONAL TGSI'S TO BE INSTALLED AND EXTEND TO SHORELINE,REFER NOTES.

    MIN.

    HARDSTAND SIZE MAY VARY DEPENDING ON EXISTING SITECONDITIONS.

    CL

    CL

    EXTENSION TO HARDSTAND AREA TO INCORPORATE BIN ANDFACILITATE ACCESS TO BACK FACE OF BUS STOP SIGNAGE.

    300TO SIGN FACE

    LIGHT POLE (SITE SPECIFIC).

    1200 MIN.

    1200

    MIN

    .

    2070 MINIMUM

    EDGE OF SHELTER TO EDGE OF HARDSTAND.

    350

    350

    2NO. 800x1300 PWD WAITING ZONES.

    APPROX. 2m AREA TO BE KEPT CLEAR OF ALL INFRASTRUCTURE FORMAINTENANCE ACCESS TO LIGHTBOX/ ADVERTISING CABINET .

    2500

    150CL

    500

    ACCESS PATHWAY MINIMUM 1200MM(WIDTH VARIES).

    *

    EXISTING OR FUTURE ACCESS PATHWAYLOCATION, CONFIRM ON SITE.

    4200

    6460 790 600

    1500

    1540 MIN. 2500 MIN.

    *

    *

    BUS ZONE SIGNREFER MUTCDPART 11

    BUS ZONE SIGNREFER MUTCDPART 11

    NOTES:HARDSTAND1 THE MANDATORY (COMPLIANT TO DSAPT) MINIMUM BOARDING POINT

    HARDSTAND AREA IS 1540MM X 2070MM, POSITIONED AS SHOWN ON T


Top Related