Transcript
Page 1: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Application of Oscilloscopes to Metrology at NPL

Matthew HarperNational Physical Laboratory,

Teddington, Middlesex TW11 0LW, UK

27th ANAMET Meeting 10th April 2007

Page 2: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Ultrafast work at NPL

• Calibration of sampling and real-time oscilloscopes– Rise-time and frequency domain– Non-linearity and timebase issues

• Calibration of pulse generators and oscilloscope calibrators– Rise-time and aberrations

• Calibration of photodiodes and photoreceivers• Power meter rise-time measurements• Jitter measurement and correction• Modulated signal measurements• Connection and delay characterisation

Page 3: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Main focus: scope-based techniques

• Oscilloscope & pulse generator calibration – EOS calibration system

• Timebase corrections – IQ technique

Page 4: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

• Oscilloscope & pulse generator calibration – EOS calibration system

••• Timebase corrections Timebase corrections Timebase corrections ––– IQ techniqueIQ techniqueIQ technique

Page 5: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Oscilloscope Calibration

Oscilloscope calibrates pulse generator

Pulse Generator calibrates oscilloscope

Page 6: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Electro-Optic Effect

E∝∆θ

EOS bandwidth is > 600 GHz

Page 7: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Photoconductive Pulse Generator

GaAs substrate

Lt-GaAs epilayer

Bias Voltage

Au metallisation

Pulses generated are < 1ps

Page 8: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Electro-Optic Sampling System

Ti:Sapphire

OscilloscopeFliter & AmplifierSi photodectors

Function generator

AOM

Lock-in Amplifier

Page 9: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Optoelectronic Calibration of Oscilloscope

EOS calibrates optically-generated

pulse

Optically-generated pulse calibrates

oscilloscope

Oscilloscope calibrates pulse generator

Page 10: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Optoelectronic Calibration of Pulse Generator

Pulse Generator calibrates oscilloscope

EOS calibrates generator

Page 11: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Traceability chain

NPL calibrated devices

EOS

Customer calibrated

devices (e.g. standards

labs)

End users

Page 12: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Main focus of talk

••• Oscilloscope & pulse generator calibration Oscilloscope & pulse generator calibration Oscilloscope & pulse generator calibration ––– EOS EOS EOS calibration systemcalibration systemcalibration system

• Timebase corrections – IQ technique

Page 13: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Principle of technique

Optical Sampling gate 1

Sampling gate 2

Sampling gate 3

Sampling gate 4

Trigger input

Sampling oscilloscope

Sampling gate 1

Sampling gate 2

Sampling gate 3

Sampling gate 4

Trigger inputTrigger

Signal A

Signal B

Signal C

Signal D

Jitter gate << Jitter trigger

Page 14: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Principle of the technique

Obtain the phase information

⎟⎟⎠

⎞⎜⎜⎝

⎛=

2

1argref

ref

AmpAmp

Phase Corrected timing of another waveform

0 1 2 3 4 5 61

0.5

0

0.5

1

Points

corr

ecte

d IQ

Sig

nals

Page 15: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Correction of waveform

• Two sinusoidal signals in quadrature allow sample time to be determined

• Determines timing of waveform measured in other channel

Page 16: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Experimental layout

Optical Sampling gate 1

Sampling gate 2

Sampling gate 3

Sampling gate 4

Trigger input

Sampling oscilloscope

Sampling gate 1

Sampling gate 2

Sampling gate 3

Sampling gate 4

Trigger input

90° Hybrid splitter

90° Hybrid splitter

I signal

Q signalReference signal

Trigger signal

Measured signal

Page 17: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

IQ errors

Two identical signals, one in phase (I) the other in

quadrature (Q)

Plotted parametrically, a circle is produced

Page 18: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

IQ errors

Errors in offset, phase and amplitude will be present

These distort, translate and rotate the circle

Page 19: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

IQ errors

In real systems there will also be noise present

Noise ‘thickens’ the parametric plot

Page 20: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Error correction

A

A

Page 21: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Pulse application

Without timebase jitter compensation

79 mUI p-p

With timebase jitter compensation

38 mUI p-p

Page 22: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

RF application

10 MHz Reference

Sampling gate 1

Sampling gate 2

Sampling gate 3

Sampling gate 4

Trigger input

Synthesizer 1

90° Hybrid splitter

Synthesizer 2

Sampling gate 1

Sampling gate 2

Sampling gate 3

Sampling gate 4

Trigger input

Synthesizer 160 GHz

90° Hybrid splitter

Synthesizer 2

Sampling oscilloscope

10 GHz

Page 23: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

RF application

RF waveform correction

Page 24: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Datacomms application

Eye diagram correction

Page 25: Application of Oscilloscopes to Metrology at NPLresource.npl.co.uk/docs/networks/anamet/members_only/meetings/27/harper.pdfMain focus: scope-based techniques ... Amp Amp Phase Corrected

Ultrafast work at NPL

• Calibration of sampling and real-time oscilloscopes– Rise-time and frequency domain– Non-linearity and timebase issues

• Calibration of pulse generators and oscilloscope calibrators– Rise-time and aberrations

• Calibration of photodiodes and photoreceivers• Power meter rise-time measurements• Jitter measurement and correction• Modulated signal measurements• Connection and delay characterisation