APPROVED MAKE LIST OF EQUIPMENT AND ACCESSORIES
1PVC rigid conduits & Accessories:
1.5 mm thick ( MMS ) ISI and FIA approved - Precision / Vraj / Nihir / BLP / PFI / Anchor / Polycab make. ( Only white coloured pipes FRLS type to be used. ).
2 L.T. Cables: Havells / KEI / Polycab / R. R. Kable.
3 Wires (FRLS): R. R. Kable / Havells / KEI / Polycab.
4 Main Distribution Boards:MDS Legrand (Lexic ) / Hager / Crabtree XPOA / Schneider ( Eazy 9 ) / L & T EXORA / C & S Wintrip / Siemens Bitaguard.
5ELCB / RCCB / Miniature Circuit Breaker:
MDS Legrand (Lexic ) / Hager / Crabtree XPOA / Schneider ( Eazy 9 ) / L & T EXORA / C & S Wintrip / Siemens Bitaguard.
6 Switch gears:
MDS Legrand (Lexic ) / Hager / Crabtree XPOA / Schneider ( Eazy 9 ) / L & T EXORA / C & S Wintrip / Siemens Bitaguard.
7 Change Over Switch: HPL Socomac/ Havells / L & T / Hager.
8 Domestic fittings:
a) All Switching Modular Accessories.
Schneider Livia / L & T oris / Crabtree Verona / Salzer S90 (Elite Plate) / Legrand Myris.
b) Holders / ceiling roses Anchor or equivalent approved make.
c) Adhesive Tape Bhor (Steel Grip) or approved .
910 - 30 A Polycarbonate Socket & Top:
MDS Legrand (Lexic ) / Hager / Crabtree XPOA / Schneider ( Eazy 9 ) / L & T EXORA / C & S Wintrip / Siemens Bitaguard.
10 Telephone Wires / Cable: Finolex / R. R. Kable / Havells / L & T / Polycab.
11 Telephone tag block: Krone make.
12 Cable Lugs: Dowell / Lotus / Jainson / 3 D.
13Cable gland Single / Double Compression:
HMI / Comet / 3D.
14 Ammeter / Voltmeter: AE / HPL /MECO/ Enercon make.
15 Selector switches: L & T salzer / Kaycee make.
16 Indicator lamps: LED type Teknic / Precifine/ Binay.
17 Connector strips: Wago / Elmex make.
18 Lighting Fixtures : Wipro / Philips / GE / Crompton / C&S. / Orient
19 Exhaust fan (Light duty): Khaitan / Crompton / Havells.
20 Ceiling Fan ( 5 star rated ): Crompton ( High Breeze Plus ) / Havells.
21Wall mounted Fan ( 5 star rated ):
Crompton ( High Flow Wave) / Havells.
22 Data Cable - I / O Unit: D - Link / Digi Link.
LIGHTING / FAN FIXTURES - SEE CAT NO. & SPECIFIED MAKE IN THE PRICE BID.CONTRACTOR SHOULD USE ONLY ONE COMPANY FOR ALL SWITCHBOARDS / DBS.
CONTRACTOR SHOULD SUBMIT SIGNED COPY OF MAKE LIST BEFORE WORK STARTED.
KAMLESH CHOKSHI
BOQ NO.
BO
Q
A
1.1
BO
Q
A
1.9
BO
Q
A
1.2
BO
Q
A
1.2
BO
Q
A
1.3
BO
Q
A
1 .4
BO
Q
A
1.9
BO
Q
A
2 .1
BO
Q
A
2 .2
BO
Q
A
3
BO
Q
B
4.1
BO
Q
B
4.1
BO
Q
B
4.2
BO
Q
B
4.2
BO
Q
B
4.3
BO
Q
B
4.5
BO
Q
B
4.6
BO
Q
B
4.7
BO
Q
B
4.7
BO
Q
B
4.8
BO
Q
B
4.8
sb 1 nr. Ele. Panel wallLDB - R 1 + inverter
DP8 M - 1 no + 2 M - 2 no 2 1 2 1 1 2 1 4 1
sb 2 bm cabin LDB - Y 1 + inverter
DP PDB - R 1 for AC 6 M - 1 no + 2 M - 2 no 1 2 1 1 1 1 4 1
sb 3on centre column nr. Ser. Mgr. table
LDB - B 1 8 M - 1 no 3 2 1 2 4sb 4 b/h. ser. Mgr. table inverter DP PDB - Y 1 for AC 4 M - 1 no + 2 M - 2 no 2 2 1 2 1
note counting machine nr. Swo 1 table
PDB - R 3 6 M - 1 no 1 1sb 5 cash room LDB - R 2 8 M - 1 no + 3 M - 1 no 1 1 1 1 1 2sb 6
nr. Locker room wall sb - backside entrance
LOOP from SB 1 - R 1
PDB - B 1 for AC 8 M - 1 no + 2 M - 2 no 2 1 1 2 1 2 2 1sb 7
b/h. sale table - on record room wall
LOOP from SB 2 - Y 1 + inverter DP
PDB - R 2 for AC 8 M - 1 no + 2 M - 3 no 2 1 1 1 1 1 1 2 1 2 1sb 8 record / stationary room LDB - Y 2 12 M - 1 no + 3 M - 1 no 2 2 1 1 2 4sb 9 locker room LDB - B 2
8 M - 1 no + 3 M - 1 no + 2 M - 1 no 1 1 1 1 1 1 2
sb 10 backside passage areaLOOP from SB 6 - R
1 + inverter DP4 M - 1 no + 2 M - 1 no 1 1 1 2 1
sb 11 o/s. ups room LOOP from SB 3 - B 1 12 M - 1 no + 2 M - 1 no 3 1 1 1 1 1 1 1 2server room
PDB - Y 3 + Panel Y phase for AC
3 M - 1 no 1 2sb 12 Pantry area
LOOP from SB 7 -Y 1
8 M - 1 no
WATER COOLER PDB - B 3 6 M - 1 no 1 1sb 13 o/s. toilet area
LOOP from SB 11 - B 1
8 M - 1 no + 2 M - 2 no 2 1 2 2 2
TOTAL 18 6 14 0 13 7 5 3 3 6 9 6 18 1 2 3 5 10 0 1 4
2 3 5
Wal
l Fan
1x20
W
led
wal
l
FIXTURES TOTAL ---------------- 10
1x36
W
led
fi
ttin
g
1x20
W
led
wal
l
1 s/
w 1
L
1 s/
w 2
L
Wal
l Fan
A.C
.
S.S.
modular box size on b
oard
pl
ug
519
Ex. F
an
15
1 s/
w 1
L
1 s/
w 3
L
S.S.
ELE. POINTS FOR STATE BANK OF INDIA , VADAVALI BRANCH, VADAVALI, GAO.
Fan
1x36
W
led
fitt
ing
1x11
W
Led
dow
n
1x10
W
MCB PHASE - LOOP FROM SB - CKT.
DAETAILS
MCB PHASE - LOOP FROM SB - CKT.
DAETAILS
S. P
lug
S.B. No. Location of S.B.
1x11
W
Led
dow
n
S. P
lug
RED COLOURED COLUMN IS CONSIDERED FOR INVERTER POINTS. CONTRACTOR SHOULD FOLLOW THE LAYOUT AS PER THIS SCHEDULE. ON SAME LOCATION, TWO SB MUST HAVE DIFF. CIRCUIT MAINS.
KAMLESH CHOKSHI
BOQ ITEM NO. BOQ
A - 1.4BOQ C - 5
BOQ C - 6
BOQ C - 8
BOQ C - 9
BOQ C - 15
BOQ C - 15
BOQ C - 15
BOQ C - 8
BOQ C - 12
BOQ C - 13
BOQ C - 14
1 BM CABIN 1 1 1 1 1 1 1 2 1 D 1 , D 2 T 1 , T 2 , T 3
2 BM CABIN CC TV 13 SER. MGR. 1 1 1 1 1 1 D 3 T 4
4 SWO 1 2 1 2 1 2 1 D 4 , D 5 T 5
5 SWO 2 2 1 2 1 2 1 D 6 , D 7 T 6
6 SWO 3 2 1 2 1 2 1 D 8 , D 9 T 7
7 SERVER ROOM 3 1 3 1 3 1 D 10 , D 11 , D 12 T 8
8 SALES TABLE 1 1 1 1 1 1 D 13 T 9
9 GRAHAK MITRA 1 1 1 1 1 1 D 14 T 10
10 LCD 1 1 1 1 D 15
11TOKEN M/C DISPLAY 1 1 1 D 16
12 QMS SYSTEM 1 1 1 D 17
13 FIRE ALARM PANEL 1 1 T 11
14 ATM 2 2 1 D 18 , D 19
15 CDM 2 2 1 D 20 , D 21
16 ECD 2 2 1 D 22 , D 23
17 SWAYAM 2 2 1 D 24 , D 25
TOTAL 2 16 8 24 1 8 1 2 0 0 25 13
UPS UPS RPP RJ-451 MTR. PATCH CORD
INTERCOM TELE.
IP TELE. FAX TELE.INTERCOM TELE.
Ferruls
DATA TELE. POINTS FOR STATE BANK OF INDIA, VADAVALI BRANCH, VADAVALI, GAO.
I/O NO. ferruls
S.B. No.
Location of S.B.2 MTR. PATCH CORD
RJ 45 CONNECT
OR
LEASE & ISDN
LINES I/O
DIRECT TELE.
CONTRACTOR SHOULD FOLLOW THE LAYOUT AS PER THIS SCHEDULE. Dual I/O plate should not be allowed.
KAMLESH CHOKSHI
MTRS. MTRS. MTRS. MTRS. MTRS. MTRS. MTRS. MTRS. MTRS. NOS NOS MTRS. MTRS. MTRS. NOS NOS NOS NOS MTRS. MTRS. MTRS. MTRS.
BOQ ITEM NO. BOQ F 25.1
BOQ F 25.2
BOQ F 25.3
BOQ F 25.4
BOQ F 25.5
BOQ F 25.6
BOQ F 25.7
BOQ F 25.8
BOQ F 25.10
BOQ F 26.1
BOQ F 26.2
BOQ F 26.3
BOQ F 26.4
BOQ F 26.5
BOQ F 26.6
BOQ F 26.7
BOQ F 26.8
BOQ F 26.10
BOQ E 24.3
BOQ E 24.4
BOQ E 24.1
BOQ E 24.2
1 EARTH PIT
2 MCCB 10 8 20
3 MAIN PANEL 30 2 30 30
4 SIGN BOARD 15 1
5 LDB 5 2 5
6 UPS I/P DB 30 2 50 50
7 ACDB PDB 5 2 5
8 ATMDB 10 2
9 DG SET
10 UPS TO UPS I/P DB 4 2
11 UPS TO UPS O/P DB 4 2
TOTAL 15 0 30 0 20 30 0 10 8 1 0 2 0 6 2 0 8 4 60 50 80 0
12 80
4 C
X 4
.0 s
q.
mm
. Cu
. CA
BL
E
MEASUREMENT SHEET FOR STATE BANK OF INDIA, MITHAPUR BRANCH, OKHA, RAO.
CABLE MEASUREMENT CABLE TERMINATIONS
4 C
X 2
.5 s
q.
mm
. Cu
. CA
BL
E
3.5
X 5
0 sq
. mm
. A
l. C
AB
LE
MA
IN P
AN
EL
4 C
X 2
.5 s
q.
mm
. Cu
. CA
BL
E
8 G
AU
GE
G. I
. W
IRE
S
4 C
X 1
0.0
sq.
mm
. Cu
. CA
BL
E
4 X
25
sq. m
m.
Al.
CA
BL
E
25 s
q. m
m.
LO
AD
WIR
ES
25 X
3
G. I
. S
TR
IP
3 C
X 6
sq
. mm
. C
u. C
AB
LE
8 G
AU
GE
Cu
. W
IRE
S
3 C
X 6
sq
. mm
. C
u. C
AB
LE
4 C
X 1
0.0
sq.
mm
. Cu
. CA
BL
E
4 C
X 4
.0 s
q.
mm
. Cu
. CA
BL
E
4 X
16
sq. m
m.
Al.
CA
BL
E
25 s
q. m
m.
LO
AD
WIR
ES
4 X
25
sq. m
m.
Al.
CA
BL
E
3.5
X 5
0 sq
. mm
. A
l. C
AB
LE
EARTHING DETAILS
4 C
X 6
.0 s
q.
mm
. Cu
. CA
BL
E
SR
. No.
MTRS.DATA CAT - 2 WIRES FROM SERVER KRONE BOX TO BSNL KRONE BOX - BOQ NO . C - 8
25 X
3 C
u.
ST
RIP
4 X
16
sq. m
m.
Al.
CA
BL
E
4 C
X 6
.0 s
q.
mm
. Cu
. CA
BL
E
2 WIRE OF 40 MTRS.
CLIENT : DATE :
PROJECT : ITEM :
a).
b).
c).
d).
e).
f).
g).
a). INSULATION WITH 1 KV MEGGER BETWEENR & Y R & NY & B Y & NB & R B & N
RYBN - Eb).
c). OPERATIONAL VOLTAGE ( 415 / 230 / 110 ) VPOWER CIRCUITCONTROL CIRCUIT
DRAWINGDRAWING
TEST
R & YY & BB & R
HIGH VOLTAGE ( 2.5 KV FOR 1 MIN. ) WITHSTAND
IDENTIFIERS / NAME PLATECOMPONENTS MAKE / RANGE
P. O. DUST & VERMIN PROOFDRAWINGSTANDARD / DRAWINGDRAWINGDRAWINGDRAWING
PANEL TEST CERTIFICATE FOR STATE BANK OF INDIA, VADAVALI, GAO.
LIGHTING PANEL
DISCRIPTION OBSERVATIONREQUIREMENTS
MIN. 50 MEGA OHMS
RYBN & EARTH
HOUSINGSEALING ARRANGEMENTFEEDER ARRANGEMENTINSIDE WIRINGBUSBAR SIZE / CLEARANCE
KAMLESH CHOKSHI
ITEM NO.
1].
2]. 5 AMP. 1000 W POWER POINT15 AMP. 3000 W POWER POINT
3].
4].
R - N Y - N B - N E - N RY YB BR
a). MAIN PANEL
b). UPS DB
5].
R - Y Y - B B - R R - E Y - E B - E N - E
a).
b).
MINUTES.MINUTES.
ohm
100 FP AMP. MCCB
TEST SHEET FOR STATE BANK OF INDIA, VADAVALI, GAO.
I. R. TEST :
LOAD TEST :
R PHASE TO EARTHY PHASE TO EARTH
EARTH RESISTANCE FOR EARTHING ELECTRODE :
VOLTAGE TEST :
INSULATION RESISTANCE TEST :
INSULATION RESISTANCE ( IN MEGA OHMS ) MEASURED BETWEEN
3.5 C X 50 sq. mm. Al. CABLE
VOLTS IN VOLTS
TEST PARTICULARS :
MEGA OHMSMEGA OHMSMEGA OHMSB PHASE TO EARTH
KAMLESH CHOKSHI
ITEM NO.
TEST SHEET FOR STATE BANK OF INDIA, VADAVALI, GAO.
TEST PARTICULARS :
6].
NOS.
a). W CONCELLED POINT WIRING
b). W CONCELLED POINT WIRING
c). W CONCELLED POINT WIRING
d). W CONCELLED POINT WIRING
e). W CONCELLED POINT WIRING
7].
a).
b).
c).
d).
Resistance of earthing electrode or earthing system mega ohms
Resistance maximum of installation mega ohms
INSULATION RESISTANCE FOR THE WHOLE INSTALLATION :
TOTAL
Between each conductors mega ohms
Between each conductors & earth mega ohms
LIGHT POINT WIRING
5 AMP. PLUG POINT
COMPUTER PLUG POINT
15 AMP. PLUG POINT
AC POINT WIRING
TOTAL LOAD CONNECTED :
PARTICULARS OF WORK TYPE OF SYSTEM WIRINGTOTAL LOAD
KAMLESH CHOKSHI
KAMLESH CHOKSHI – DISHITA ELECTRICALS
IMPORTANT POINTS TO BE NOTED
1) Rates for LIGHT, FAN, EX. FAN, CALL BELL, RAW POWER ETC. POINTS includes the cost
of main wires and PVC pipes from LDB-ROW POWER DB to DIFFERENT
SWITCHBOARDS WITH REQUIRE CIRCUITS .
2) Rates for COMPUTER POWER POINTS include the cost of wires and PVC pipes from UPS
DB to COMPUTER POWER POINTS.
3) Rates for COMPUTER I/O include the cost of DATA cables and PVC pipes from SERVER
SWITCH to COMPUTER NODES.
4) Rates for TELE POINTS include the cost of TELEPHONE Wires and PVC pipes from
EPABX/CRONE BOX to TELE. POINTS.
5) Rates for A.C. / POWER POINTS include the cost of wires and PVC pipes from A.C. DB to
DIFFERENT A.C. AND POWER POINTS WITH REQUIRE CIRCUITS.
6) THE CONTRACTOR SHOULD SUBMIT THE BUILTUP SLD OF PANEL, SLD OF
DIFFERENT DBS TO DIFFERENT SWITCHBOARDS WITH NUMBERING, SLD OF
DATARACK TO DIFFERENT I/O POINTS WITH NUMBERING, TELE. KRONE BOX TO
DIFFERENT TELE. POINTS WITH NUMBERING, ETC. AFTER EXECUTION OF THE
BRANCH. – 2 SETS OF COPIES – 1 WITH LAMINATION.
7) THE CONTRACTOR SHOULD USE MAX. 3 CIRCUITS IN ONE CONDUIT FOR UPS &
RAW POWER POINTS.
8) THE CONTRACTOR SHOULD USE MAX. 3 WIRES OF DATA & TELE. IN ONE
CONDUIT.
9) EVERY CONDUIT FOR UPS , RAW POWER , DATA & TELE., POWER POINTS, AC
POINTS , LIGHTING POINTS SB SHOULD BE SEPARATE.
10) FOR DATA & TELE. POINTS, BIG JUNCTION BOX MUST BE REQUIRED.
11) FOR UPS & RAW POWER POINTS, BIG/ SMALL JUNCTION BOX MUST BE REQUIRED.
12) EMPTY CONDUIT MUST BE LAID FOR SECURITY SYSTEM.
13) PVC CONDUITS MUST BE CLAMPED WITH SADDLES IN CEILING ONLY.
14) ELE. CONTRACTOR MUST SUBMIT CERTIFIED LOAD LIST WITH ELE. LICENSE NO. /
SUPERVISOR CERTIFICATE NO.
15) CONTRACTOR SHOULD SUBMIT TEST REPORT.
16) CONTRACTOR SHOULD PRESENT EARTHING PLATES BEFORE EXECUTION.
( I )R - N M. OHMS :
Y - N M. OHMS :
B - N M. OHMS :
( ii ):
:
( iii )
1 OHM :2 OHM :3 OHM :
4 - N - E Volts :
( iv )
( v )
( vi )
( vii )
DATE :
PLACE :
SIGNATURE OF ELECTRICAL SUPERVISOR -
PERMIT NO. :
SIGNATURE OF ELECTRICAL
CONTRACTOR - LICENSE NO. :
15 A - 1000W Power Point - 15 Minutes
EARTH RESISTANCE FOR EACH ELECTRODE IS
CERTIFICATE OF MAKES OF MATERIALS USED IN THE WORK :
CERTIFIED THAT THE EARTHING PALTE / PIPE HAS BEEN VERIFIED AND PLACED AT CORRECT
DEPTH CONFIRMING TO IE RULES.:
CERTIFIED THAT THE ELECTRIFICATION WORK HAS BEEN CARRIED OUT UNDER THE SUPERVISION OF LICENSED ELECTRICAL SUPERVISIOR :
CIRCUIT DIAGRAM:
INSULATION TEST CERTIFICATE BY ELECTRICAL CONTRACTOR
THIS CONTRACTOR IS TO CERTIFY THAT THE WORK IS CARRIED OUT CONFIRMING TO IE RULES & CODE OF PRACTICE. HE HAS TO GIVE THE TEST REPORT IS UNDER :
5 A - 1000W Power Point - 15 MinutesLOAD TEST IS
INSULATION RESISTANCE TEST IS
KAMLESH CHOKSHIDISHITA ELECTRICALS
ELE. CONSULTANT:KAMLESH CHOKSHIDISHITA ELECTRICALSVADODARA
LOAD CALCULATION 09426032096 (M) 08128874936 (M)
No. Load items Qty Kw. Total Kw.NO.
A] A.C.1 1.0 TR HW 2 1.20 2.402 1.5 TR HW 1.80 0.003 2.0 TR HW 3 2.40 7.204 3.0 TR CASSETTE 3.60 0.005 4.0 TR CASSETTE 4.80 0.006 7.5 TR DUCTABLE 9.00 0.007 8.5 TR DUCTABLE 10.20 0.008 17.0 TR VRF 20.40 0.00
B] LIGHTING FIXTURES1 1 X 40 W LED SQUARE 15 0.04 0.602 12 W LED FIXTURE 19 0.015 0.293 1 X 10 W MINOLTA 2 0.01 0.024 1 X 18 W DOWN LIGHTER 0.04 0.005 1 X 20 W T/L 10 0.02 0.206 CEILING FAN 5 0.06 0.307 WALL FAN / PEDSTRAL FAN 6 0.06 0.368 EX. FAN 3 0.07 0.219 LCD 2 0.25 0.50
10 WATER COOLER / FREEZE 1 0.3 0.3011 SIGN BOARD 1 1.00 1.0012 1 X 36 W STREETLIGHT 0.04 0.0013 BORE MOTOR 0.75 0.00
C] COMPUTER SYSTEM1 UPSS - 10 KVA 8.00 0.002 UPSS - 5 KVA 1 4.00 4.003 UPSS - 3 KVA 2.40 0.004 UPSS - 2 KVA 1 1.60 1.605 UPSS - 1 KVA 0.80 0.006 COMPUTERS 10 0.25 2.507 PRINTERS - BIG 1 0.30 0.308 PRINTERS - DRAFT / PASSBOOK 4 0.30 1.209 NOTE COUNTING M/C 1 0.50 0.50
10 ATM 1 5.00 5.00TOTAL LOAD REQUIRED KW 28.48
TOTAL LOAD SANCTIONED
EXTRA LOAD DEMANDED KW 28.48
31.64
KW = 1.71 *V*I*0.85PER PHASE AMP. 44.52
BRANCH: SBI VADAVALI BRANCH, GAO.
DEMAND LOAD IN KVA
[email protected]@gmail.com
Ramp Ramp
RECORD ROOM
3700 X 4250
LOCKER ROOM
3650 X 2450
CASH ROOM
2300 X 3070
L.TOILET
1220 X 2000
G.TOILET
1530 X 2000
PANTRY
2480 X 2000
UPS
2150 X 2000
SERVER
1840 X 3180
2.0
TR
2
2.0 TR
32.0 TR
4
1
1.0
TR
8
1.0
TR7
5
1.0
TR
6
1.0
TR
1.0
TR
low
height storage
ATMCDM
SWA
YAM
ECD
ELE. PANELLDB, ACDB - PDB,EMERGENCY DB
BRANCH HEAD
3350 X 2800
SER.MANAGER
ENTRY
E lobby
3700 X 2900
T R A N
S A C T I O
N
SALES
GRAHAK MITRA
SW
O 1
SW
O 2
SW
O 3
FAN POINT (1200 MM SWEEP)
20 A / 25 A. DP MCB WITH METAL ENCLOSURE FOR A.C.
5/15 A SOCKET WITH SWITCH
SWITCH BOARD WITH 5 A PLUG POINT
L E G E N D
DBS. & ELE. PANEL,
1X40 W LED RECESS MOUNTED TUBE LIGHT (2' X 2')
area 84.27 sq. mtrs. : 595 W LED fixutres ::: 7.06 W / sq. mtr.area 165.45 sq. mtrs. : 28.48 KW load :::: 0.172 KW / sq. mtr. :::: 172 W / sq. mtr.
SPEAKER POINT
L E G E N D
EXHAUST FAN
1 X 20 W LED SURFACE MOUNTED TUBE LIGHT - 4' FEET
1 x 7 W LED SURFACE MOUNTED (U.T) FIXTURE
WALL FAN
1 X 36 W STREET LIGHT FIXTURE ( CFL)
DECORATIVE HANGING LIGHT - LED
3 W LED LIGHT
DECORATIVE EYE BALL 6 W LED LIGHT
L E G E N D
5 A SOCKET ONLY
5 A SWITCH + 5 A SOCKET
PICTURE LIGHT POINT
1X11W LED DOWNLIGHTER LIGHT POINT
* DWGS. ARE PROPERTY OF "STUDIO 919 "& SHALL NOT BE COPY WITHOUT PERMISSION
50
010
25
100
50
100
25
100NOTE :
* ALL DIMENSIONS ARE TO BE READ, NOT TO BE MEASURED.
*ALL DIMENSIONS ARE IN FEET - INCHES
* BEFORE STARTING CONSTRUCTION, THE CONTRACTOR/SUB CONTRACTOR SHALL REVIEW AND VERIFY. ALL
DRGS,DIMENSION AND CONDITIONS, DISCREPANCIES. IN THE DRGS, OR IN BETWEEN THE DRGS AND ACTUAL. FIELD
CONDITIONS SHALL BE REPORTED TO THE ARCHITECTS BEFORE STARING CONSTRUCTION.
* THE ARCHITECTS SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR/ SUB CONTRACTOR
COMPLIANCE WITH SAFETY AND REGULATION.
*ANY AMBIGUITY FOUND, CONTACT ARCHITECT / INTERIOR DESIGNER BEFORE EXECUTION.
* DWGS. ARE PROPERTY OF "STUDIO 919 ARCHITECTS"& SHALL NOT BE COPY WITHOUT PERMISSION
STUDIO 919SBI-VADAVALI
NTS
SHAILESH
DEVDATT
06.08.18
DEVDATT PANDYA+91 9879 234 919
Architect
"VADAVALI" BRANCH AT, GUJARAT.STATE BANK OF INDIA
2nd Flr. - 8, AJITNATH SOC., Nr. PALDI P.O.,AHMEDABAD - 380007, INDIA.
TELEFAX: 079 - 26630154, EMAIL: [email protected]
01
ELECTICAL LAYOUTdate: 06.08.2018
low
height storage
low
height storage
low
height storage
Ramp Ramp
ATMCDM
SWA
YAM
ECD
electrical panel
BRANCH HEAD
3350 X 2800
SER.MANAGER
ENTRY
RECORD ROOM
3700 X 4250
E lobby
3700 X 2900
LOCKER ROOM
3650 X 2450
T R A N
S A C T I O
N
CASH ROOM
2300 X 3070
L.TOILET
1220 X 2000
G.TOILET
1530 X 2000
PANTRY
2480 X 2000
UPS
2150 X 2000
SERVER
1840 X 3180
1075mm WIDE PASSAGE
low
height storage
DA
TA R
AC
KTE
LE. K
RO
NE
BOX
UPS I/P DBUPS O/P DB
QMSMACHINE FIRE
ALARMPANEL
TOK
ENM
AC
HIN
ED
ISPL
AY
LCD
TV
CCTV
1]. For data rack - two ups points should be laid from diff. ups units for continuous power supply of data rack.2]. In E Lobby - two ups points should be laid from diff. ups units for continuous power supply of ATM.3]. ONE SEPARATE UPS CIRCUIT SHOULD BE LAID IN BM CABIN FOR CCTV & COMPUTER SUPPLY.4]. 6 A. S. PLUG UPS SUPPLY FOR FIRE ALARM SYSTE & ONE TELE. POINT .5]. 6 A. S. PLUG UPS SUPPLY & DATA I/O FOR QM SYSTEM .
SALES
GRAHAK MITRA
SW
O 1
SW
O 2
SW
O 3
F
D 1 , D 2T 1 , T 2 , T 3
D 3T 4
D 4 , D 5T 5
D 6 , D 7T 6
D 8 , D 9T 7
D 10 , D 11 , D 12T 8
D 13T 9
D 14T 10
D 15
D 16
T 11
D 1
8 , D
19
D 2
0 , D
21
D 2
2 , D
23
D 2
4 , D
25
D 17
L E G E N D2 NOS. 6 A. SOCKET WITH ONE NO.
6 A. SWITCH.
2 NOS. 6 A. SOCKET + ONE NO. 16 A.
SOCKET WITH ONE NO. 16 AMP.
SWITCH WITH INDICATOR.
COMPUTER DATA I/O NODE.
L E G E N D
F
INTERCOM TELE. RJ 11 JACK POINT.
DIRECT TELE. RJ 11 JACK POINT.
IP TELE. RJ 45 JACK POINT.
FAX TELE. RJ 11 JACK POINT.
UPS DB - I/P DB & O/P DB.
L E G E N D300 X 300 X 40 mm FLOOR JUNCTION BOX.
150 X 150 X 40 mm FLOOR JUNCTION BOX.
UPS / RAW POWER - PIPE LINE.
DATA / TELE. - PIPE LINE.
20 / 25 mm DIA. PIPE BEND.
* DWGS. ARE PROPERTY OF "STUDIO 919 "& SHALL NOT BE COPY WITHOUT PERMISSION
50
010
25
100
50
100
25
100NOTE :
* ALL DIMENSIONS ARE TO BE READ, NOT TO BE MEASURED.
*ALL DIMENSIONS ARE IN FEET - INCHES
* BEFORE STARTING CONSTRUCTION, THE CONTRACTOR/SUB CONTRACTOR SHALL REVIEW AND VERIFY. ALL
DRGS,DIMENSION AND CONDITIONS, DISCREPANCIES. IN THE DRGS, OR IN BETWEEN THE DRGS AND ACTUAL. FIELD
CONDITIONS SHALL BE REPORTED TO THE ARCHITECTS BEFORE STARING CONSTRUCTION.
* THE ARCHITECTS SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR/ SUB CONTRACTOR
COMPLIANCE WITH SAFETY AND REGULATION.
*ANY AMBIGUITY FOUND, CONTACT ARCHITECT / INTERIOR DESIGNER BEFORE EXECUTION.
* DWGS. ARE PROPERTY OF "STUDIO 919 ARCHITECTS"& SHALL NOT BE COPY WITHOUT PERMISSION
STUDIO 919SBI-VADAVALI
NTS
SHAILESH
DEVDATT
06.08.18
DEVDATT PANDYA+91 9879 234 919
Architect
"VADAVALI" BRANCH AT GUJARAT.STATE BANK OF INDIA
2nd Flr. - 8, AJITNATH SOC., Nr. PALDI P.O.,AHMEDABAD - 380007, INDIA.
TELEFAX: 079 - 26630154, EMAIL: [email protected]
01
NETWORK LAYOUTdate: 06.08.2018
MAIN MCCB FPBOX 100 A.
3.5 C X 50 sq.mm.AL Cable
MAIN PANEL FP MCCB100 A.
CHANGE OVER
125 A. Al. BUS BAR
25 sq.mm.singlewire (4 wires)
40A DP+Timer for signboard(1 nos)
4 C x 2.5 sq.mm.Cu Cable
FOR signboard
MAIN PANEL
UPS I/P DBDP
UPS 1
UPS O/P DB
BANKINGHALL UPSPOINTS
SERVERUPSPOINTS
S. L. D. FOR PANEL & DBS WIRING + CABLING
DISHITA ELECTRICALSELECTRICAL CONSULTANT
GF, 30/B, UMA COLONY, WAGHODIA ROAD,VADODARA - 390019.094260 32096(M) , 081288 74936 (M)[email protected], [email protected],[email protected]
RINA CHOKSHI
KAMLESH CHOKSHI(B.E. ELECTRICAL)
01-08-2018.
ELE. CONTROL DIAGRAM.
LOCATION : - VADAVALI BRANCH, VADAVALI.
CLIENTS : - VADAVALI BRANCH, STATE BANK OFINDIA , GAO.
DATE DRAWNBY:SCALE
PROJECTTYPE: CHECKEDBY
REV.DATE
REV.NO.
6 sq.mm.singlewire (2 wires)
25A DP+Timer for SERVER AC(1 nos)
2x4.0 sq.mm. + 1x2.5 sq. mm. wires
FOR SERVER AC
125 A. Al. BUS BAR
4 sq.mm.single wire (1 wires) USED FOREARTH WIRE
25 sq.mm.singlewire (4 wires)
DG SET
10 sq.mm.X 4Ccable
UPSCIRCUITS
40 Amp.FPLDB MCB
FORLDB
6 sq.mm.singlewire (4 wires)
63 Amp.SPAREMCB
6 sq.mm.singlewire (4 wires)
THE CONTRACTOR SHOULD FOLLOW THIS PANEL SLD & GA DRAWING & MAKE THE PANEL WITH CPRI / ERDA GUIDELINES , TERMS & CONDITIONS. ALSO SUBMIT THE TEST CERTIFICATE AS PER PERFOMA GIVEN IN TENDER.
63 Amp.ACDBPDBMCB
FORACDBPDB
4 C x 16 sq.mm.Al. Cable
10 sq.mm.singlewire (4 wires)
4 C x 16 sq.mm.Al. Cable
10 sq.mm.X 3Ccable
UPS I/P DBDP
UPS 2
UPS O/P DB
6 sq.mm.X 4Ccable
UPSCIRCUITS
6 sq.mm.X 3Ccable
4 sq.mm.singlewire (2 wires)
06A DP+Timer for digital clock(1 nos)
2x2.5 sq.mm. + 1x1.0 sq. mm. wires
FOR digitalclock
10 sq.mm.singlewire (4 wires)
10 sq.mm.singlewire (4 wires)
63 Amp.FPATMDB MCB
FORATMDB
4 C x 16 sq.mm.Al. Cable
10 sq.mm.singlewire (4 wires)
63 Amp. FPUPS DBMCB
FORUPSDB
4 C x 6 sq.mm.Cu Cable
G. A. DRAWING FOR MAIN PANEL - SBI VADAVALI BRANCH, GAO.
cablealley
busbarchamber
changeoverswitch
FP MCCBwithbusbar
busbarchamberA - V metersselector switchescontrol fuses
Indicator lampscontrol fuses
leftsideview
1 nos DPMCB
signboard+ Timer
+ Contactor
rightsideviewcable
alley
1 nos FPMCBs
forUPS
DB
1 nosDP
MCBserver
AC
1 nosDP
MCBdigital
clock
1 nos FPMCBs
forACDB
PDB
1 nosFP
MCBsfor
SPARE
1 nos FPMCBs
forATM
DB
1 nosFP
MCBsfor
LDB
Ramp Ramp
ATMCDM
SWA
YAM
ECD
electrical panel
BRANCH HEAD
12'-0"X9'-0"
low
height storage
SER.MANAGER
low
height storage
ENTRY
low
height storage
RECORD ROOM
12'-0" X 13'-10"
E lobby
12'-0" X 10'-0"
LOCKER ROOM
11'-11" X 8'-0"
BANKING HALL
27'-1" X 33'-1"
S A L E S
T R A N
S A C T I O
N
CASH ROOM
7'-6" X 10'-0"
L.TOILET
4'-0" X 6'-6"
G.TOILET
5'-0" X 6'-6"
PANTRY
8'-1" X 6'-6"
UPS
7'-0" X 6'-6"
SERVER
6'-0" X 10'-4½"
3'-6" WIDE PASSAGE
5'3"
5'3"
5'3"
7'-1
0"3"
9'
300 X 300 X 40 mm FLOOR JUNCTION BOX.
150 X 150 X 40 mm FLOOR JUNCTION BOX.
UPS / RAW POWER - PIPE LINE.
DATA / TELE. - PIPE LINE.
1 # 25 MM PIPE
fix 1" PVC bends of 10 nos.
here from this j. box
1 # 25 MM PIPE
8'-2"
5"
1'9'
-6"
1'10
'-9"
2"
5'-2" 1'8'
-3"
1'
5'-2"
8'-2"
2'
10'-5
"
3'-8"
1'-3"
6'5'
-3"
3 # 25 MM PIPE
2 # 25 MM PIPE
4 # 25 MM PIPE
2 # 25 MM PIPE
3 # 25 MM PIPE
1 # 25 MM PIPE
3 # 25 MM PIPE
3 # 25 MM PIPE
2 # 25 MM PIPE
2 # 25 MM PIPE2 # 25 MM PIPE
3 # 25 MM PIPE
1 # 25 MM PIPE
5 # 25 MM PIPE
1 # 25 MM PIPE
9 # 25 MM PIPE
4 # 25 MM PIPE
2 # 25 MM PIPE
3 # 25 MM PIPE
fix 1" PVC bends of 10 nos.
here from this j. box
fix 1" PVC bends of 10 nos.
here from this j. box
* DWGS. ARE PROPERTY OF "STUDIO 919 "& SHALL NOT BE COPY WITHOUT PERMISSION
50
010
25
100
50
100
25
100NOTE :
* ALL DIMENSIONS ARE TO BE READ, NOT TO BE MEASURED.
*ALL DIMENSIONS ARE IN FEET - INCHES
* BEFORE STARTING CONSTRUCTION, THE CONTRACTOR/SUB CONTRACTOR SHALL REVIEW AND VERIFY. ALL
DRGS,DIMENSION AND CONDITIONS, DISCREPANCIES. IN THE DRGS, OR IN BETWEEN THE DRGS AND ACTUAL. FIELD
CONDITIONS SHALL BE REPORTED TO THE ARCHITECTS BEFORE STARING CONSTRUCTION.
* THE ARCHITECTS SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR/ SUB CONTRACTOR
COMPLIANCE WITH SAFETY AND REGULATION.
*ANY AMBIGUITY FOUND, CONTACT ARCHITECT / INTERIOR DESIGNER BEFORE EXECUTION.
* DWGS. ARE PROPERTY OF "STUDIO 919 ARCHITECTS"& SHALL NOT BE COPY WITHOUT PERMISSION
STUDIO 919SBI-VADAVALI
NTS
SHAILESH
DEVDATT
06.08.18
DEVDATT PANDYA+91 9879 234 919
Architect
"VADAVALI" BRANCH AT GUJARAT.STATE BANK OF INDIA
2nd Flr. - 8, AJITNATH SOC., Nr. PALDI P.O.,AHMEDABAD - 380007, INDIA.
TELEFAX: 079 - 26630154, EMAIL: [email protected]
01
FLOOR CONDUIT LAYOUTdate: 06.08.2018