CatalogueUV Sensor and Monitor
Tel: +86-138 1039 5896 email: [email protected] web: www.haisenuv.com
Pro
vid
e a
be
tte
r li
fe
Haisen Technik Co., Ltd
Provide a better life
Overview01 70001001 HS1-U Sensor with 0~5VDC output, G1/4”
02 70001002 HS1-I Sensor with 4~20mA output, G1/4”
03 70002001 HS2-U Sensor with 0~5VDC output, G1/2”
04 70002001 HS2-I Sensor with 4~20mA output, G1/2”
05 70003001 HS3-U Sensor with 0~5VDC output, G3/4”
06 70003002 HS3-I Sensor with 4~20mA output, G3/4”
07 70004001 HS4-U Sensor with 0~5VDC output
08 70004002 HS4-I Sensor with 4~20mA output
09 70005001 HS5-I Sensor with 4~20mA output for Medium Pressure Lamp
10 70005001 HS5-IZY Sensor with 4~20mA output for Medium Pressure Lamp
11 71001001 HM-1 UV monitor
12 71003001 HM-3 UV monitor
52
Dimensions
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
0~5V 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS1-U voltage output >1KΩ
www.haisenuv.com
Suitable Monitor Types
HM-1, HM-2, HM-3, HM-4, HM-5
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20mW/cm2
Resolution 0.01mW/cm2
Weight: 150g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)
Wiring Diagram
65.049.0
14.0
SW
19
G1/
4"
UV SensorBrownBlueBlack
+5V DC+5V DCVoutGND
53
Dimensions
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
4~20mA 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS1-I current output >1KΩ
www.haisenuv.com
Suitable Monitor Types
PLC or Other equipment
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the PLC or other equipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20mW/cm2
Resolution 0.01mW/cm2
Weight: 150g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)
Wiring Diagram
65.049.0
14.0
SW
19
G1/
4"
-
+
Blue(Signal)
Brown
UV Sensor
PLC
+24VDC
GND
4~20mA -
4~20mA +R1
250~680Ω
54
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
0~5V 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS2-U voltage output >1KΩ
www.haisenuv.com
Suitable Monitor Types
HM-1, HM-2, HM-3, HM-4, HM-5
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20mW/cm2
Resolution 0.01mW/cm2
Weight: 180g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)
Wiring Diagram
UV SensorBrownBlueBlack
+5V DC+5V DCVoutGND
Dimensions
59.042.0
13.0
Φ24
.0
G1/
2"
55
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
4~20mA 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS2-I current output >1KΩ
www.haisenuv.com
Suitable Monitor Types
PLC or Other equipment
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the PLC or other equipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20mW/cm2
Resolution 0.01mW/cm2
Weight: 180g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)
Wiring Diagram
-
+
Blue(Signal)
Brown
UV Sensor
Dimensions
59.042.0
13.0
Φ24
.0
G1/
2"
PLC
+24VDC
GND
4~20mA -
4~20mA +R1
250~680Ω
56
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
0~5V 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS3-U voltage output >1KΩ
www.haisenuv.com
Suitable Monitor Types
HM-1, HM-2, HM-3, HM-4, HM-5
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20mW/cm2
Resolution 0.01mW/cm2
Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)
Wiring Diagram
UV SensorBrownBlueBlack
+5V DC+5V DCVoutGND
Dimensions
58.0
41.5
15.0 11.5
SW
30
G3/
4"
Φ23
.0
57
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
4~20mA 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS3-I current output >1KΩ
www.haisenuv.com
Suitable Monitor Types
PLC or Other equipment
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the PLC or other quipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20mW/cm2
Resolution 0.01mW/cm2
Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)
Wiring Diagram
Dimensions
58.0
41.5
15.0 11.5
SW
30
G3/
4"
Φ23
.0
-
+
Blue(Signal)
Brown
UV Sensor
PLC
+24VDC
GND
4~20mA -
4~20mA +R1
250~680Ω
58
Haisen Technik Co., Ltd
Normal UVC Sensor
Monitoring of relative/absolute UV-intensity
0~5V 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS4-U voltage output >1KΩ
www.haisenuv.com
Suitable Monitor Types
HM-1, HM-2, HM-3, HM-4, HM-5
The UVC sensor serves as robust, long-time
stable measuring head for the precise
measurement of UVC irradiances in UV water
disinfection systems and UV Air purification
systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20W/cm2
Resolution 0.01mW/cm2
Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LCable: Length 2.5m(longer on request)
Wiring Diagram
Dimensions
?16
.5
214.0
175.0
18.6
12.6
GNDVout
+5V DC+5V DC
WhiteBlackRed
UV Sensor
59
Haisen Technik Co., Ltd
Normal UVC Sensor
Monitoring of relative/absolute UV-intensity
4~20mA 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS4-I Current output >1KΩ
www.haisenuv.com
Suitable Monitor Types
PLC or other equipment
The UVC sensor serves as robust, long-time
stable measuring head for the precise
measurement of UVC irradiances in UV water
disinfection systems and UV Air purification
systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the UV-Monitor PLC or other equipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 20mW/cm2
Resolution 0.01mW/cm2
Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LCable: Length 2.5m(longer on request)
Wiring Diagram
Dimensions
?16
.5
214.0
175.0
18.6
12.6
Red
Black(signal)
+
-UV Sensor
PLC
+24VDC
GND
4~20mA -
4~20mA +R1
250~680Ω
60
Haisen Technik Co., Ltd
UV Monitor for UVC Sensor with Relay Contacts
and Status Indication by Digital Tube
UV Monitor HM-1
www.haisenuv.com
Monitoring of relative UV-intensity (depending
on sensor type) (%).
The mains-driven panel meter HM-1 serves with
the respective sensors for a continuous
radio-metric control of lamps, especially UV
radiators. Different UV and visible spectral
ranges can be controlled with the corresponding
sensors.
Technical Data
Measuring range: 0~19999μW/cm2
Resolution +/- 0.2% Weight: 320g Operating temp.: 0~50oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 85~265VAC 50/60Hz Dimensions: 48X48X84mmOpen Dimensions: 45X45mmSensor signal input: 0~5V DCRelay contact for alarm: 1 X time-over
and 1 X UV low contact
Wiring Diagram
Dimensions
SET
48
48
84
76
HM-1
Time-over contact
8
6
7 UV Low contact
9
10
3
1
2
4
5
Power supply 85~265V AC
Sensor signal input
+5V DC
GND
62
Haisen Technik Co., Ltd
UV Monitor for UVC Sensor with Relay Contacts
and Status Indication by 16X2 LCD
UV Monitor HM-3
www.haisenuv.com
Monitoring of relative and absolute UV-intensity
(depending on sensor type) .
The mains-driven panel meter HM-3 serves with
the respective sensors for a continuous
radio-metric control of lamps, especially UV
radiators. Different UV and visible spectral
ranges can be controlled with the corresponding
sensors.
Technical Data
Measuring range: 0~20000μW/cm2
Resolution +/- 0.2% Weight: 420g Operating temp.: 0~50oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 85~265VAC 50/60Hz Dimensions: 96X48X74mmOpen Dimensions: 92X45mmSensor signal input: 0~5V DCSignal Output: 1X4~20mA and 1X1~5V DCRelay contact for alarm: time-over and UV
low contact
Wiring Diagram
Dimensions
HM-3
13
11
12
14
15
3
1
2
4
5
Power supply 85~265V AC
Sensor signal input
+5V DC
GND
8
6
7
9
10
18
16
17
19
20
1~5V DC_
+
4~20mA
96 74
66
_
+
48
63
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
4~20mA 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS5-I current output >1KΩ
www.haisenuv.com
Suitable Monitor Types
PLC or Other equipment
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the PLC or other quipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 250mW/cm2
Options measuring range:500 or 1000mW/cm2
Resolution 1mW/cm2
Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)
Wiring Diagram
Dimensions
-
+
Blue(Signal)
Brown
UV Sensor
PLC
+24VDC
GND
4~20mA -
4~20mA +R1
250~680Ω
92.0
50.0 17.0
G3/
4"
64
Haisen Technik Co., Ltd
Waterproof UVC Sensor
Monitoring of relative/absolute UV-intensity
4~20mA 210~280nm
Sensor Type Signal Output Value
Spectral Range
Load Impedance
HS5-IZY current output >1KΩ
www.haisenuv.com
Suitable Monitor Types
PLC or Other equipment
The waterproof UVC sensor serves as robust,
long-time stable measuring head for the
precise measurement of UVC irradiances in
UV water disinfection systems and UV Air
purification systems.
A superior long-time stability and corrosion
resistance is achieved by the selection of
suitable materials.
The sensor can be directly connected to the PLC or other quipment via the connector. Thus integration into UV-lamp monitoring, adjustment and control is possible.
Spectral Sensitivity
Wavelength(nm)
Technical Data
Measuring range: 500mW/cm2
Options measuring range:250 or 1000mW/cm2
Resolution 1mW/cm2
Weight: 420g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10bar
Wiring Diagram
Dimensions
UV Sensor
PLC
+24VDC
GND
4~20mA -
4~20mA +R1
250~680Ω
1 2
3
+ -
4~20mA 12/24VDC
12
3
+
-
12
Haisen Technik Co., Ltd
UV Monitor for UVC Sensor with Relay Contacts
and Status Indication by Digital Tube
Manual of HM-1 and HS1,2,3-U
www.haisenuv.com
C-01: setting the low limit relative value for 50% or other value
0~99%C-02: setting the operate time of alarm
0~9999 hoursE-01: low limit relative valueE-02: more than the operate
Wiring Diagram
+5V DC Brown
UV SensorVout Blue
GND Black
Parameter Specification
1. Press + into the setting interface.
Parameter Setting
2. Press , you can choose the parameter which you want to setting(C-01 and C-02).
3. Press , you can choose the digit of C-01 and C-02. Then press and confirm the value you need.
4. Press button, until stop flashing.
6. Press + button and back to the operate interface.
5. Press button and rerurn to the 2 step.
HM-1
Time-over contact
8
6
7 UV Low contact
9
10
3
1
2
4
5
Power supply 85~265V AC
Sensor signal input
+5V DC
GND
Press more than 5 seconds for the default value Setting:
C-01: 50%C-02: 8000 hours
13
Haisen Technik Co., Ltd
UV Monitor for UVC Sensor with Relay Contacts
and Status Indication by 16X2 LCD
Manual of HM-3 and HS1,2,3-U
www.haisenuv.com
AV: absolute value of uv instensityRV: relative value of uv instensity AT: timerC-00: setting the relative value 100%C-01: setting the low limit relative
value for 50% or other valueC-02: setting the operate time of alarm
Monitor HM-3
13
11
12
14
15
3
1
2
4
5
Power supply 85~265V AC
Sensor signal input
+5V DC
GND
8
6
7
9
10
18
16
17
19
20
1~5V DC_
+
4~20mA_
+
Wiring Diagram
+5V DC Brown UV SensorVout Blue
GND Black
Parameter Specification
1. Press + into the setting interface.
Parameter Setting
2. Press , you can choose the parameter which you want to setting(C-00, C-01 and C-02).
3. Press , you can choose the digit of C-00, C-01 and C-02. Then press and confirm the value you need.
4. Press for 3 seconds and comfirm and finish the setting.
6. Press + and back to the operate interface.
5. Press for less than 1 second and rerurn to the 2 step