UPS (Uninterruptible Power Supply) Digital Signal Processor
CM COMANDOS LINEARESCM COMANDOS LINEARES
M ult i Ac t iveThree PhaseC O N C E P T I O N
-
A B O U T T H EC O M PA N Y
With over 32 years in operation, CM Comandos is one of the
largest UPS manufacturers in Latin America.
Moreover, it is the sole leader in solutions for the corporate market. Certified by
ISO-9001:2015 standards, CM Comandos stresses its commitment to excellence of
its products and full clients satisfaction
Innovation, quality, technology and reliability. Trademarks ofCM Comandos Lineares solutions
U S A G E UPS of CM Comandos Lineares are suitable for critical-mission usage in all types of corporations,
providing protection against power disturbances, such as cuts, micro cuts, noise, harmonic distortion,
spikes, transients, under and over voltage and frequency variations.
TECHNICAL SUPPORT
B E N E F I T S CM Comandos equipment operates with greater precision, adds more features and are safer.
CM COMANDOS LINEARES
O SD LN IA NM EAO
RC EM SC
ISO9001
2015
Features that create high reliability and productivity in many types of applications, diminish flaws and
hence maintenance costs. In short, being a CM Comandos client means having the return on capital
invested and guarantees that only a company with wide technical support can offer.
By choosing the brand CM Comandos Lineares you can count on the best
technical support prior and post-sales from a company that has established
itself over these 30 years as the market leader.
State-of-the-art instrumentation, highly skilled workers, with national coverage and 24-hour service,
seven days a week, call center and certified processes ensure the excellence of our support services.
Q YUALIT
-
High Technology in Digital Signal Processing - DSP
T H E M O S T M O D E R NC O R P O R AT E U P S
We are living in an increasingly fast and practical world. A world connected by processors, chips, software and
peripherals. But this is still not enough. That is why the world is moving forward to immediately processing data
technologies. CM Comandos Lineares is one step ahead and offers its clients products with a revolutionary
technology, called Digital Signal Processing - DSP.
All the line of Multi Active UPS Conception has DSP
technology. Feature that provides high performance and
reliability
for critical-mission applications, i.e. it protects the applications where continuous operation is of critical
importance.
can be upgraded adding new features
in already installed units.
Today, this technology is present in the most sophisticated electronic systems due to its high speed and reliability.
Digital Signal Processors can process tens of millions of samples per second. This means real-time processing - the
signal is processed at the same time it is received, without delays or slowdowns.
Designed with heavy use of DSP technology resources, Multi Active UPS Conception adds new and advanced
features that create a new development concept, in which equipment firmware
If you are thinking about purchasing an
UPS, count on CM Comandos solutions ,
which ensures state-of-the-art
technology, maximum protection,
digital precision and real-time
processing.
200kVA Model
-
O N L I N E T E C H N O LO G Y W I T HS TAT I C M A I N T E N A N C E B Y PA S S
M A I N F E AT U R E S
Advanced TechnologyDSP (Digital Signal Processor)
Internal Memory for 5 Thousand Records
True RMS Measurements with Multimeters Accuracy
Static Maintenance Bypass
Real-Time Remote Management Software
Multi Active Parallel System (Exclusive CM)
Allows advanced and exclusive features in real time.
They are ideal for non-linear load measurement.
Add protection and increase of sensitive load reliability.
Via TCP / IP with password protection for remote access, shutdown.
t can be parallel as many units as needed, allowing system expansion, according to consumer demand.
Allows tracking for analysis.
I
Display TFT 4,3" Touch Screen(Standard Item)
Possibility of DSP Firmware Upgrade
DSP-Monitored Actions
Smart Control of the Cooler Speed
Modern screen with touch commands, which allows UPS access via the Internet
Ensures the use and preservation of investment.
The actions are registered and recorded in the event log.
They extend the life of equipment.
OutputMains Input
Input Alternating Current
Direct Current
Output Alternating Current
Alternating Current Static Bypass
Maintenance Alternating Current Static Bypass
Static Maintenance Bypass
It allows transfer and return of the UPS load to an alternate
circuit of power supply for maintenance purposes. In any
case, the power supply is continuous with no interruption.
Rectifier Converts the energy
from the mains of the utility provider or the generator into direct current, correcting or
eliminating system input disturbances.
InverterIt converts the direct current from the rectifier or battery into alternating current output, shaped like a pure sine wave, disturbance-free.
Battery bankStores backup power to power the UPS over a predetermined period, known as UPS runtime.
Static BypassProtection system that,
in case of problems,
automatically transfers
the load to an alternate
circuit without breaking
the power supply.
Present Mains
Mains Failure
Static Bypass
Maintenance Static Bypass
Multi Active UPS ConceptionThree Phase
REMOTE MANAGEMENTINTERFACE
DISPL AY TFT 4 ,3” TOUCHSCREENTOUCH COMMAND
They are made up of several tools. The
NetMate SNMP Adapter allows you to
remotely manage the UPS via the
Internet through a web browser,
monitor status and send alerts via
email.IP Power software is a Windows
Application management tool and the
Client version is specific to automate
the shutdown of servers, being able to
automatically and simultaneously
disconnect multiple servers and
stations.The ArmModbus Adapter allows
integration of the UPS via aRS485, to Building Automation
Systems.
-
M U LT I A C T I V E PA R A L L E L S Y S T E M ( E X C L U S I V E O F C M C O M A N D O S )
CM Comandos Lineares has developed an innovative and pioneering system in the world of parallelism between UPSs. Multi
Active Parallel System allows system expansion, according to your consumption demand and may parallel as many units needed
to meet your demand, increasing system capacity and its application reliability.
P O S S I B I L I T Y O F P O W E R S U M M A T I O N
It allows connection to power summation, using two or more UPSs to meet the demand of full load. When used for power summation, it allows the connection of UPSs with different powers. When the connection is made with UPS of different powers, the load will be distributed proportionately.
It allows parallel redundant connection N + 1, N + 2, N + 3 ... N + X, allowing the disengagement of one or more units, keeping the active load.
R E D U N D A N T P A R A L L E L C O N N E C T I O N
Communication between UPS is the common communication bus, where information goes by, including charge level, timing and status of the bypass.
C O M M U N I C A T I O N B E T W E E N U P S
All UPSs are autonomous, operate independently in the system
and have individual control.
N O M A S T E R O R S L A V E U P S
As many units can be parallel as needed, allowing system expansion, according to consumption demand.
U N L I M I T E D P A R A L L E L I S M
B AT T E R Y B A N K PA R A L L E L I S MAllows battery bank paralleling (when they are of the same nominal voltage).
U P S M A I N T E N A N C E
It allows insertion and removal of UPS from the system without the need to stop.
S H U T D O W N I N T E R FA C E A N D R E M O T E M A N A G E M E N T
Input Mains
Output
UPS 1 Power of 50 kVA
UPS 2 Power of 100 kVA
UPS 3Power of 20 kVA
Load Provided by the System = 400 kVA
UPS 4Power of
30 kVA
UPS 5Power of 80 kVA
UPS 6 Power of 120 kVA
Multi-Servers Multiplatform Multi-O.S.
D UPSMON Remote Management Interface
F
Interface Shutdown
H Software UPSMON Remote Station with internet connection
Ethernet Local Network
A UPSMON Management Interface
PC withInternet
C Interface Shutdown Client LAN
DB9 Microprocessor PortRJ45 Ethernet Network
B Interface Shutdown
E SNMP Web Monitoring
G
Software integrating all UPS monitoring
-
CM
.MKT
103
.1 R
EV.1
0 - S
peci
ficat
ions
are
sub
ject
to c
hang
e w
ithou
t pre
viou
s no
tice.
We
enco
urag
e re
cycl
ing
T E C H N I C A L D ATA
Input
Voltage: • Three Phase: 208 / 220 / 380 / 400 / 440V
Allowance variance: • ± 15% of nominal voltage
Frequency: 50 or 60 Hz
Variation of Allowable Frequency: ± 8%Settingon:
• Three Phase: 3F + N + TPower Factor:
• 0,8 • 0,99*
Output
Voltage: • 208 / 220 / 380 / 400 / 440V
Available Power: • 5/10/15/20/30/40/60/80/100/120/160/200 kVA
Static Regulation: ± 1% nominal
Frequency: 50 or 60 Hz Frequency Variance:
• ± 0,05% in battery modeSetting:
• Three Phase: 3F +N + T
Power Factor: 0,8
Waveform: sine
Harmonic Distortion THD: less than 1%, total
Peak Factor: 3:1
Overload Capacity: 125% for 25s
Efficiency: 90%
Batteries
Line Voltage: • 288VDC (5 to 30 kVA • 384VDC (40 to 80 kVA) • 480 VDC (100 to 200 kVA)
Recharge System: controlled, automaticRecharge Time:
• 8 to 10 hours for 90% of load
Type: sealed, maintenance-free
Static Bypass
Action: automatic, DSP controlled
Transfer Time: 0ms (null)
Retransfer to Normal Mode: automatic
Maintenance Static Bypass
Allows UPS Maintenance without disconnecting the load
Action: manual, through Circuit Breaker
Change to Normal Mode: without interruption
Electrical Protections
Input and Output Undervoltage and Overvoltage
DC Undervoltage and Overvoltage and Battery
Overload and Short Circuit
Minimum Battery Discharge
Over temperature
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Physical and Mechanical Features
Compact dimensions TFT 4.3" Touch Screen Cabinet structure:
• Rack: metal • Removable side and top covers • Finish: epoxy powder painting in graphite color
with thermal and anticorrosive treatment Ventilation: forced, with digital speed control by
DSPIsolation Transformer: electrostatics ShieldedCommunication port:
• Serial RS232C Isolated Full Duplex -DB9 Female* • Dry Contact DB9 Female
Management Interfaces
Single and multi-user, client-server, multi-serverMultiple servers on a single UPSShutdown and Management ToolsProtocols:
• Serial Rs232 • Serial Rs485* • SNMP / Telnet / http / TCP/IP*
Management software * • UPSMAN / UPSMON / RCCMD • ASNMP CS121BL Adapter •
Environments and operating systems • Windows 8 / 10 / 2010 • Linux
(Brands of reuse manufacturers) * Optional
n
n
n
n
n
n
n
n
n
n
n
n
UNMS II
*
MeasurementTrue RMSOutput power in kVAOutput power in kWOutput Power FactorOutput VoltageOutput CurrentOutput FrequencyBattery voltageBattery current *Input Power Factor*Input voltageInput Current *Input Frequency
n
n
n
n
n
n
n
n
n
n
n
n
n
AlarmsControlled by the DSP processorTypes of Alarms:
• Sound: » Network Missing: 1 ring each 4 sec » Pre-alarm of Batteries: 1 ring per second » Internal UPS Failure: continuous alarm
• Alert Messages: » LCD » Software UPSMON, local or remote » Message by e-mail, cell phone or pop-up: - Normal Operation - Network Failure - Pre-alarm of Batteries - Active Static Bypass - Active Manual Bypass - Output Overload - Fail
n
n
Event LogStored Records:
• Memory with 25,500 records (15 configuration logs and 495 event logs)
• Indications of Date, time and occurrence • Measurements • Operation Status and Panel Alarms • Status of Internal Switches
Autonomy of NVRAM: • 5 years (with UPS off )
n
n
Operating FeaturesAudible Noise: 55 dBA to 60 dBA at 1 meterMTBF (Mean Time Between Failures): 200,000 hoursMTTR (Mean Time To Repair): 30 minutesAmbient Temperature:
• UPS: 20ºC to 40ºC • Batteries: 0ºC to 30ºC • Recommended: 20ºC and 25ºC
Relative Humidity: • 0% to 95% non-condensing • Recommended: 45% to 55%
Altitude: up to 1,000mRecommended Environment Type:
• Intern, indoor installation • Atmosphere: clean, free from conductive particles, toxic, flammable liquids and gases.
Degree of Protection: IP-20
n
n
n
n
n
n
n
n
5000 5,0 900 X 480 X 980 295
10000 10,0 900 X 480 X 980 305
15000 15,0 900 X 480 X 980 409
20000 20,0 1180 X 550 X 980 560
30000 30,0 1180 X 550 X 980 640
4
60000 60,0 1355 X 720 X 940 560
80000 80,0 1900 X 780 X 920 730
100000 100,0 1900 X 785 X 925 870
120000 120,0 1900 X 785 X 925 1000
160000 160,0 1900 X 1265 X 1000 1200
200000 200,0 1900 X 1265 X 1000 1300
300000 300,0 2010 X 2050 X 1000 2280
0000 40,0 1355 X 720 X 940 490
Model Power kVA
Physical Dimensionh x w x d
mm
Weight (with
batteries)
Models with internal batteries
Physical Dimensionh x w x d
mm
Power kVA
Weight (with
batteries)
Model
Models with no battery
Sistema de Sustentabilidade Auditada
CM COMANDOS LINEARES
O SD N L IA NM EO A
C R EM SC
ISO9001
2008
O SD N L IA NM EO A
C R EM SC
ISO9001
2015Q YUALIT
Av. Eng. Alberto de Zagottis, 760 - 04675-085 - São Paulo - SP - BrazilPhone.: (+55 - 11) 5696-5000 www.cmcomandos.com.br
Página 1Página 2Página 3Página 4Página 5Página 6