PR
E S
CH
OO
L #
3
110
PR
E S
CH
OO
L #
2
112
TO
ILE
T
111
TO
ILE
T
115
TO
ILE
T
113
PR
E S
CH
OO
L #
1
114
TO
DD
LE
RS
A
116
TO
ILE
T
117
TO
ILE
T
119
TO
DD
LE
RS
B
118
LO
UN
GE
122
LA
UN
DR
Y
121
PA
NT
RY
120
ELE
C
125
TO
ILE
T
124
INF
AN
TS
A
123
INF
AN
TS
B
126
ME
CH
128
TO
ILE
T
127
TW
AD
DLE
RS
129
TO
ILE
T
131
TO
ILE
T
130
PR
E-K
-K
132
OF
FIC
E
102
VE
ST
IBU
LE
100
RE
CE
PT
ION
101
CL.
103
ISO
104
CO
RR
IDO
R
133
PR
EP
PE
RS
A / M
BB
105
PR
EP
PE
RS
B
109
TO
ILE
T
106
TO
ILE
T
108
TO
ILE
T
107
PROPOSED TRASH ENCLOSURE(REFER TO DETAILS 1,2,3/SP-102)
NEW 1 STORY BUILDING
10,000 S.F. DAYCARE FACILITY
40 PARKING SPACES
Academy of Early Education
PROPERTY LINE(TYP.)
6' WHITE PVC FENCE &GATES (REFER TO SHEETA-151)
MONUMENT SIGN SEESHEET A-161
PLAYGROUND(REFER TO SHEETSA-151 & A-152)
5,076 S.F.
PLAYGROUND
4' WHITE PVC FENCE &GATES (REFER TO SHEETA-151)
ROAD D- PRIVATE ROAD
ROAD APRIVATE ROAD
COVERED ENTRANCEWAY
5' CONCRETE SIDWALK
ARCHITECTURAL SITE PLAN GENERAL NOTES:
1. THIS ARCHITECTURAL SITE PLAN IS NOT INTENDED FOR
PLANNING OR ZONING REVIEW, AND IS PROVIDED FOR
COORDINATION PURPOSES ONLY. ALL SITE DESIGN SHALL BE
CONFIRMED WITH AND COMPLETED PER THE APPROVED CIVIL
SITE DRAWINGS AS PREPARED BY:
To Be Determined
2. THE G.C. SHALL BE SOLELY RESPONSIBLE FOR AND HAVE
CONTROL OVER CONSTRUCTION MEANS, METHODS,
TECHNIQUES, PROCEDURES, COMPLIANCE WITH APPLICABLE
ORDINANCES AND JURISDICTIONAL JOB SITE REQUIREMENTS,
AND FOR COORDINATING ALL PORTIONS OF THE PHASED WORK
UNDER THE CONTRACT UNLESS OTHER SPECIFIC INSTRUCTIONS
CONCERNING THESE MATTERS HAVE BEEN PROVIDED THROUGH
THE DEVELOPER.
3. REFER TO THE CIVIL DRAWINGS FOR ALL SITE DIMENSIONS,
GRADING AND EROSION CONTROL, UTILITY INFORMATION,
LANDSCAPE AND IRRIGATION DESIGN AND ALL OTHER REQUIRED
SITE RELATED IMPROVEMENTS.
4. PRIOR TO PROCEEDING WITH ROUGH GRADING, THE G.C. SHALL
COORDINATE CIVIL GRADES WITH ELEVATIONS SPECIFIED AS
PART OF THE ARCHITECTURAL SCOPE OF WORK (INCLUDING,
BUT NOT LIMITED TO COMPARISON OF TOP OF FINISH GRADES
AT PERIMETER OF BUILDING, FLAT WORK AND ADJOINING SITE
AREAS). ALL QUESTIONS SHALL BE SUBMITTED IN WRITING TO
THE CIVIL ENGINEER AND ARCHITECT PRIOR TO START OF WORK.
5. THE G.C. SHALL ROUGH GRADE AND RE-COMPACT BUILDING
PADS PER THE SOILS REPORT AS PART OF THE SITE SCOPE OF
WORK.
6. ALL GRADING AND CONCRETE PAVING SHALL SLOPE AWAY FROM
THE BUILDING. CONTACT THE DEVELOPER, ARCHITECT AND CIVIL
ENGINEER IN WRITING REGARDING ANY AREAS THAT CANNOT
SLOPE AWAY DUE TO EXISTING CONDITIONS.
7. THE G.C. SHALL VERIFY ALL SITE DIMENSIONS TO APPLICABLE
BOUNDARIES AND SETBACK INFORMATION WITH PARCEL MAP
ALTA SURVEY OF RECORD AND NOTIFY OWNER, ARCHITECT, AND
CIVIL ENGINEER IN WRITING OF ANY QUESTIONS IN THIS REGARD.
8. THE G.C. SHALL COORDINATE ALL SITE UTILITY RUNS WITH THE
APPROPRIATE UTILITY COMPANIES AND PER THE APPROVED
SITE PLANS. UTILITY RUNS SHALL BE STUBBED 5'-0" FROM THE
BUILDING PERIMETER AT THE LOCATION INDICATED IN THE
APPROVED M.E.P. DRAWINGS.
9. THE G.C. SHALL PROTECT EXISTING CONDITIONS TO REMAIN
FROM DAMAGE. DAMAGED ITEMS SHALL BE REPLACED,
REPAIRED, OR RESTORED BY THE G.C. IF, IN THE OPINION OF
THE G.C., EXISTING CONDITIONS TO REMAIN WILL BE DAMAGED
OR REQUIRE REMOVAL, THE GENERAL CONTRACTOR SHALL
IDENTIFY THESE TO THE DEVELOPER PRIOR TO PROCEEDING
WITH REMOVAL.
KEY PLANscale: 1"=20'-0"1FOR ANY SITE DATAPURPOSES ONLY. REFER TO CIVIL DRAWINGSTHIS SITE KEY PLAN IS FOR COORDINATION
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\S
P-1
01
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
NORTH
ARCHITECTURAL
SITE PLAN
SP-101
SV
PRE SCHOOL #3
110
PRE SCHOOL #2
112
TOILET
111
TOILET
115
TOILET
113
PRE SCHOOL #1
114
TODDLERS A
116
TOILET
117
TOILET
119
TODDLERS B
118
LOUNGE
122
LAUNDRY
121
PANTRY
120
ELEC
125
TOILET
124
INFANTS A
123
INFANTS B
126
MECH
128
TOILET
127
TWADDLERS
129
TOILET
131
TOILET
130
PRE-K-K
132
OFFICE
102
VESTIBULE
100
RECEPTION
101
CL.
103
ISO
104
CORRIDOR
133
PREPPERS A / MBB
105
PREPPERS B
109
TOILET
106
TOILET
108
TOILET
107
REC-1
FE-1
5432
B
1 6
A
C
ISO-1
CL-1
PKK-1 PKK-2
3 3 3 3
33333
OF-1
3
VES-1
A A
C C C C CC C C C C C
C
B B
PS-3-2
CO-1-1
FE-1
3
A051
3
A051
4
A051
2
A051
1
PS-3-1TO-A-1 TO-B-1
IN-A-1
IN-A-2
IN-B-2
IN-B-1
MEC-1
TW-1
TW-2
PEPB-1PEPB-2
TO-B-2TO-A-2
PS-2-1 PS-2-2 PS-1-1 PS-1-2
VES-2
ELC-1
PAN-1
SL-1
LAN-1
PS-3-3
PS-2-3
PS-1-3
TO-A-3
TO-B-3
ST-1
TW-3
PEPB-3
IN-A-3
IN-B-3
CO-2
ST-2
FE-1
FE-2
3
3
3
M
PKK-3
A061
1
A061
2
B B
B B
B B
PEPA-1PEPA-2
PEPA-3
FE-2
8
13B
15
8
7
5
8
10
6
8
4
11
18
17
1
16
4
16
12
4
9
14
88
8
12
8
12
3
1
8
13A
2
1
M
M
M
MM
M
M
M
M
M
M
2
TYP.
A-081
7
GROSS AREA 10,000 S.F.
* CALCULATED LESS BUILT-IN ITEMS
18-24 MO.1/62121/35458TODDLERS B
1/4
PRE-SCHOOL #1 3-4 YRS.
PRE-SCHOOL #2 1/35
4-5 YRS.
1/35540
525
525 15 1
S.F.
NET*
6125 6651 -- 175 18 --
2
--TOTALS
24-30 MO.1/111/35TWADDLERS
5-6 YRS.PRE K-K 1/25
GROUPRATIOTEACHERSCHILDRENPER S.F.S.F.
AGETEACHER# OFRATIO CHILDACTUALROOM
LICENSING CALCULATIONS
420
15 1
1/35875 25 1
The Learning Experience, Pasco County, Florida
375INFANT A 1/46 WK-12 MO.
280 8 2
1/15
1/15
813
911
6362
STATE
REQUIRED
S.F.( 35 S.F.
PER CHILD)
527
775
420
880
337
# OF
PLAY AREA 5,076 S.F.
1201/35PRE-SCHOOL #3
3-5 YRS.
700 711700 1/20
1/4INFANT B 1/412 MO.-18 MO.
8 2
18-24 MO.1/62121/35458TODDLERS A 420 420
1/35
1/35
375280 337
220700 30-36 MO.1/111/35PREPPERS B 712701
540527
2 30-36 MO.1/111/35PREPPERS A / MBB 758738700
700
20
20
#
FE-X
FE-X
101
KEYNOTE NUMBER;
ROOM NUMBER
DOOR NUMBER;
REFER TO DRAWINGS A-121 AND A-122 FOR DOOR SCHEDULE,
DOOR HARDWARE SCHEDULE, AND DETAILS
WINDOW STYLE;
REFER TO DRAWING A-123 FOR WINDOW SCHEDULE,
ELEVATIONS AND DETAILS
NUMBER OF BIN CUBBIES (BC) OR BATH SHELVES (BS); REFER
TO DRAWINGS A-131; BIN CUBBIES SHOWN FOR AREA
CALCULATIONS ONLY, AND TO BE PROVIDED BY GC. EXACT
LOCATIONS TO BE COORDINATED WITH TLE.
DRINKING FOUNTAIN;
REFER TO DRAWING A-111 FOR INSTALLATION DETAILS AND
P-100 FOR SPECIFICATIONS
BLIND SPOT MIRROR, KLEAR-VU BY BROSSARD #P-180;
18" DOME STYLE CONVEX MIRRORS FOR BLIND SPOTS IN
ROOMS TO BE MOUNTED @ 6" BELOW FINISH CEILING. EXACT
NUMBER AND LOCATIONS TO BE COORDINATED WITH TLE.
CEILING MOUNTED CAMERA;
MOUNTED CAMERAS TO BE INSTALLED TO ENSURE ADEQUATE
COVERAGE THROUGHOUT, INCLUDING AT THE EXTERIOR FOR
THE PLAYGROUND. EXACT QUANTITY AND LOCATIONS TO BE
COORDINATED WITH TLE. REFER TO SPECIFICATIONS FOR
FURTHER INFORMATION.
FIRE EXTINGUISHER; WALL HUNG, BRACKET
FE-1 = 5lb B:C, FE-2 = 10lb A:B:C (1 PER 3,000 SQ.FT.)
MANUFACTURER: JL COSMIC
BRACKET COLOR: WHITE
INSPECTION TAGS REQUIRED FOR ALL FIRE EXTINGUISHERS
FIRE EXTINGUISHER; WALL HUNG, SEMI-RECESSED CABINET
FE-1 = 5lb B:C, FE-2 = 10lb A:B:C (1 PER 3,000 SQ.FT.)
MANUFACTURER: JL COSMIC
MODEL: 1017F10 WITH ROUNDED CORNERS
CABINET COLOR: WHITE
INSPECTION TAGS REQUIRED FOR ALL FIRE EXTINGUISHERS
LAUNDRY APPLIANCES (SIDE-BY-SIDE; TYPICAL)
WASHER MODEL: G.E. GTW485ASJWS (ENERGY STAR)
DRYER MODEL: WHIRLPOOL WED95HEDW (ENERGY STAR)
LAUNDRY APPLIANCES (STACKABLE; ONLY IF SHOWN ON PLAN)
WASHER MODEL: G.E. GFWN1600J (ENERGY STAR)
DRYER MODEL: G.E. GFDN160EJ (ENERGY STAR)
M
D
W
D
W
CONSTRUCTION PLAN LEGEND:
A
X
BC#
BS#
1. REFER TO STRUCTURAL DRAWINGS FOR ALL STRUCTURAL
INFORMATION.
2. ALL ANGLED WALLS, IF SHOWN ON FLOOR PLAN, SHALL BE
45° UNLESS NOTED OTHERWISE.
3. ALL OUTSIDE CORNERS WITHIN ALL ROOMS SHALL HAVE
3
4
"
RADIUS PVC CORNER BEADS AT ALL CORNERS AND
GYPSUM BOARD WINDOW RETURNS - SEE DETAILS 2 & 3
/A-091
4. FOR PARTITION DESIGNATIONS REFER TO DRAWING A-012
AND DRAWING A-091 FOR PARTITION TYPE DETAILS.
5. PREPPERS A (MBB) ENLARGED PLANS - SEE SHEET A-101
6. REFER TO DRAWING A-111 FOR ENLARGED TOILET ROOM
PLANS AND DRINKING FOUNTAIN DETAILS. REFER TO P-100
FOR SPECIFICATIONS.
7. REFER TO DRAWING A-043 FOR FURNITURE AND
MILLWORK PLANS.
8. ALL MILLWORK ELEVATIONS & DETAILS - SEE SHEET A-131
& A-132. BOOKSHELVES ARE NOT SHOWN IN THE
CONSTRUCTION PLANS. COORDINATE WITH TLE FOR
EXACT LOCATION(S).
9. FOR PANTRY SEE SHEET A-133
10. FOR RECEPTION AREA ENLARGED PLANS - SEE SHEET
A-134
11. OUTSIDE PLAYGROUND ENLARGED PLANS - SEE SHEETS
A-151, A-152 AND A-153
12. REFER TO DRAWING T-200 FOR LIST OF REQUIRED AND
APPROVED VENDORS.
13. REFER TO SPECIFICATIONS DRAWINGS FOR INSTALLATION
INFORMATION.
14. REFER TO SPECIFICATIONS DRAWINGS FOR ALL
APPLIANCE, LOW VOLTAGE COMPONENT, AND
PLAYGROUND EQUIPMENT SPECIFICATIONS. LOW
VOLTAGE COMPONENT LOCATIONS AND QUANTITIES
SHALL BE COORDINATED WITH "THE LEARNING
EXPERIENCE."
15. THE ENTIRE BUILDING SHALL BE THOROUGHLY CLEANED,
INCLUDING WAXING & POLISHING, AT THE COMPLETION OF
CONSTRUCTION.
16. DRYWALL CONTROL JOINTS TO BE FAS-093X BY CLARK
DIETRICH (OR APPROVED EQUAL) AND SHALL BE ALIGNED
WITH DOOR OR WINDOW JAMB (LEFT OR RIGHT) AT
MAXIMUM INTERVALS OF 30'-0". ALSO REFER TO DETAIL 2
ON A-042.
CONSTRUCTION PLAN GENERAL NOTES:
CONSTRUCTION PLAN KEYNOTES:
CONCRETE SIDEWALK. REFER TO APPROVED SITE PLANS FOR FINISHES AND DETAILS. ENSURE SIDEWALKS ARE CLEAR OF OBSTRUCTIONS.
PROVIDE FENCING AROUND ANY POTENTIAL SAFETY HAZARDS TO PREVENT ACCESS BY CHILDREN
PROVIDE CONCRETE PAD AND CANVAS AWNING. PROVIDE PICNIC TABLES AS SHOWN. REFER TO DRAWINGS A-151 & A-152 FOR ADDITIONAL
INFORMATION
4 FT. TALL LATTICE STYLE FENCE AND GATE. SEE A-151 FOR MORE INFORMATION
PITTCON 6" RADIUS SO-LRT OUTSIDE CORNER WITH TANGENT FINS BY SOFTFORMS. REFER TO DETAIL 4 ON DRAWING A-091
BENCH SEAT - SEE DETAIL 3/A-134
LCD TV/DVD TO BE MOUNTED at 7'-8" A.F.F. WITH EASYMOUNT FULLY ADJUSTABLE, SWING-OUT BRACKET FASTENED TO STUDS. PROVIDE 2x10
BLOCKING (32" WIDE) BEHIND TV.- FLUSH WITH BOTTOM OF OUTLET & CENTERED ON OUTLET. LOCATION TO BE COORDINATED WITH "THE LEARNING
EXPERIENCE." REFER TO DRAWING T-300 FOR SPECIFICATIONS
PROVIDE MONITOR TO BE MOUNTED ON (2) WALL-MOUNTED BRACKETS WITH 2X10" BLOCKING (32" WIDE)- FLUSH WITH BOTTOM OF OUTLET AND
CENTERED ON OUTLET. REFER TO DETAIL 2 ON DRAWING A-134
SMART BOARD TO BE INSTALLED BY TENANT- REFER TO DETAILS ON DRAWING A-091
INSTALL (1) WIRE SHELF 16" DEEP MOUNTED AT 6'-0" A.F.F.; FASTENED DIRECTLY TO STUDS. PROVIDE 2x10 BLOCKING AS REQUIRED. LAUNDRY:
WALL TO WALL SHELF
PROVIDE (5) 16" DEEP WIRE SHELVES IN THE CLOSET, WALL TO WALL. FIRST SHELF AT 20" A.F.F., THEN 34", 48", 62", & 76" A.F.F. (5 SHELVES TOTAL).
PROVIDE 2x10" BLOCKING AS REQUIRED.
ROOF ACCESS LADDER - SEE ELEVATIONS AND ROOF PLAN.
DOWNSPOUT - CONNECT TO STORM SEWER
DRINKING FOUNTAIN - A = HIGH, B = LOW
WATER HEATER SUSPENDED FROM STRUCTURE ABOVE; REF PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION
BATH SHELVES; REFER TO DETAIL 1/A-131
INSTALL INFANT CHAIR RAIL AT 36" AFF OVER CARPETED SECTION OF ROOM IN INFANT ROOM ONLY. PAINTED "W" PER DRAWINGS A-042.
FIRE RISER
ELECTRICAL METER AND DISCONNECT
CONSTRUCTION
PLAN
A-011
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
11
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
NORTH SCALE:
1
CONSTRUCTION PLAN
1/8"=1'-0"
SV | KT
PRE SCHOOL #3
110
PRE SCHOOL #2
112
TOILET
111
TOILET
115
TOILET
113
PRE SCHOOL #1
114
TODDLERS A
116
TOILET
117
TOILET
119
TODDLERS B
118
LOUNGE
122
LAUNDRY
121
PANTRY
120
ELEC
125
TOILET
124
INFANTS A
123
INFANTS B
126
MECH
128
TOILET
127
TWADDLERS
129
TOILET
131
TOILET
130
PRE-K-K
132
OFFICE
102
VESTIBULE
100
RECEPTION
101
CL.
103
ISO
104
CORRIDOR
133
PREPPERS A / MBB
105
PREPPERS B
109
TOILET
106
TOILET
108
TOILET
107
5432
26'-8"31'-0"29'-3"26'-0"31'-9"
B
144'-8"
38
'-9
"3
0'-3
"
1 6
A
C
69
'-0
"
35
'-0
"3
4'-0
"
69
'-0
"
8"
2'-8
"
8"
6'-8"6'-0"16'-4"10'-4"12'-0"5'-8"11'-4"5'-8"11'-4"6'-0"16'-8"6'-0"15'-4"6'-0"9'-4"
14
'-2
"7
'-0
"7
'-6
"1
0'-2
"1
0'-0
"2
0'-2
"
2'-8
"
9'-4"
7'-4"23'-4"7'-4"16'-4"8'-8"8'-8"16'-4"7'-4"23'-4"7'-4"9'-4"
6'-0
"
16'-3"
19'-4
1
2
"
2'-11"
24'-10
1
2
"
30'-7" 4'-6"
3'-9
"5
'-0
"
8'-2
1 2
"
10
'-7
1 2
"
14
'-1
"
13
'-1
0"
8'-8
1 2
"
10'-3"
6'-11"
25'-11"
8'-0
"
8'-8
1 2
"
15
'-5
"
6'-5
"
2'-9"
4'-1
"
14'-10
1
2
"
11'-6"
8"
2'-8"
8"
20'-8"3'-4"2'-8" 20'-8" 3'-4"
72'-4" 72'-4"
6'-6" 3'-3" 3'-3" 16'-3" 3'-3"13'-8" 3'-3" 13'-8"
11'-6"
1'-8"
6'-5" 7'-9"
4'-4"
2'-2"
7'-1
1"
7'-1
0"
30
'-5
1 2
"
6'-0"
15'-8
1
2
"
5'-5
"5
'-0
"
8'-0
"
8'-8
1 2
"
6'-1
1"
10
'-0
"
4'-1
0"
8'-8
"
6'-5
"
4'-0
"
6'-1
1"
4'-0
"
6'-1
1"
4'-0
"
10
'-1
1"
4'-0
"
7'-5
"
10
'-1
1"
4'-0
"
4'-0
"
10
'-0
"4
'-0
"
10
'-0
"4
'-0
"
A-061
2
A-061
1
17
'-8
"
16
'-1
0
1 2
"
7'-1
1"
7'-1
1"
6'-9
1 2
"
1
2'-4"
3'-4"
2'-4"
3'-4"
3'-4
"
16
'-8
"
44
4
4
4
4
4
4
4
4
44
4
4
4
2
2
1
1
2
2
12
2
222
2
2
3
3
3
3
3
3
3
3
1
1
1
1
3
22
2
2
2
2
2
2
2
2
2
2
2
2
1
2
2
1
2
2
2
2
1
2
2
2
2
2
3
2
3
2
3
2
1
2
1
1
1
1
11
1
20
'-3
"4
'-0
"
1
8'-8
1 2
"
3'-8
"3
'-8
"
1
1
1
1
1
1
1'-2"
TOTAL GROSS SQUARE FOOT =
10,000 SQUARE FEET
2'-3
"
9'-9" 3'-5"
TYP.
A-081
7
23'-6" 21'-0" 21'-0" 22'-9"56'-5"
9'-6
"
9'-6
"
NOTE: INSTALL DOOR FRAME SO
THAT HINGE SIDE OF DOOR OPENING
IS 4" FROM ADJACENT WALL, UNLESS
NOTED OTHERWISE.
NOTE: INSTALL DOOR FRAME SO
THAT HINGE SIDE OF DOOR
OPENING IS 6" FROM ADJACENT
WALL, UNLESS NOTED OTHERWISE.
NOTE: INTERIOR WINDOWS ADJACENT
TO DOORS SHALL BE INSTALLED SUCH
THAT A MINIMUM OF 1'-6" WALL SPACE
IS MAINTAINED BETWEEN THE DOOR
FRAME AND THE WINDOW FRAME,
UNLESS OTHERWISE NOTED ON THE
PLAN. INSTALLATION OF LIGHT SWITCH
BOX & TELEPHONE BOX REQUIRED.
LOCATIONS:
· ALL TOILET ROOMS
· RECEPTION
· OFFICE
· LAUNDRY
· JANITOR'S CLOSET
4"
6"
6"
1'-6"
U.N.O.
INTERIOR PARTITION
3
PLUMBING WALL
2
EXTERIOR WALL ASSEMBLY
(REF. WALL SECTIONS)
REFER TO A-091 FOR PARTITION DETAILS
4
PARTITION LEGEND:
FULL HEIGHT INTERIOR PARTITION
1
1. ALL DIMENSIONS SHOWN ARE MEASURED TO THE
CENTER LINE OF INTERIOR FRAMING OR EXTERIOR
FACE OF THE FOUNDATION WALL UNLESS NOTED
OTHERWISE.
2. ALL INTERIOR WALLS ARE 4.75" THICK UNLESS
OTHERWISE NOTED.
3. REFER TO DRAWING A-091 FOR ADDITIONAL PARTITION
TYPE INFORMATION.
4. REFER TO DRAWING A-011 FOR ADDITIONAL GENERAL
NOTES, KEY NOTES, AND SYMBOL LEGEND.
GENERAL NOTES:
1
DIMENSION OF BLOCKING AT SMART
BOARD. REFER TO DETAILS 1/A-082.
KEY NOTES:
NORTH
DIMENSION
PLAN
A-012
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
12
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
SCALE:
1
DIMENSION PLAN
1/8"=1'-0"
SCALE:
2
TYP. HINGE SIDE DOOR TO WALL
NTS
SCALE:
3
ALT. HINGE SIDE DOOR TO WALL
NTS
SCALE:
4
CONSTRUCTION BETWEEN DOOR
& INTERIOR WINDOW
NTS
SV | KT
2'X4' ARMSTRONG 1729 FINE FISSURED, WHITE LAY IN ACOUSTIC
TILE WITH SQUARE LAY-IN JOINTS. PRELUDE 15/16" EXPOSED TEE
GRID OR EQUAL
2'X4' ARMSTRONG 2910 RANDOM FISSURED, WHITE LAY-IN
ACOUSTIC TILE WITH MYLAR FINISH AND SQUARE LAY-IN JOINTS.
PRELUDE 15/16" EXPOSED TEE GRID OR EQUAL
2'X2' ARMSTRONG 584, WHITE LAY-IN ACOUSTIC TILE WITH REVEAL
EDGE JOINTS. PRELUDE 15/16" EXPOSED TEE GRID OR EQUAL
GYPSUM BD. SOFFIT
2X4 LIGHT - 2'X4' RECESSED LED LIGHT FIXTURE. 'A3' TAG
INDICATES ALTERNATE LAMPING ONLY WHERE INDICATED. REFER
TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE.
2X4 LIGHT - 2'X4' RECESSED LED EMERGENCY NIGHT LIGHT
FIXTURE WITH BATTERY BACK-UP. 'A3' TAG INDICATES ALTERNATE
LAMPING ONLY WHERE INDICATED. REFER TO ELECTRICAL
DRAWINGS FOR LIGHT FIXTURE SCHEDULE.
2X2 LIGHT - 2'X2' RECESSED LED LIGHT FIXTURE (REFER TO
ELECTRICAL DRAWINGS - LIGHT FIXTURE SCHEDULE).
2X2 LIGHT - 2'X2' RECESSED LED EMERGENCY NIGHT LIGHT
FIXTURE WITH BATTERY BACK-UP (REFER TO ELECTRICAL
DRAWINGS - LIGHT FIXTURE SCHEDULE).
LOGO SIGN - "THE LEARNING EXPERIENCE" ILLUMINATED SIGNAGE
MOUNTED ON CANOPY - SEE DRAWING A-161.
WB - WALL BRACKET - LED LIGHT FIXTURE (REFER TO ELECTRICAL
DRAWINGS - LIGHT FIXTURE SCHEDULE) MOUNTED @ +8'-6" AFF.
PROVIDE FIXTURE WITH PROTECTIVE WIRE CAGE.
RECESSED LED DOWN LIGHT AT UPPER LEVEL MAKE BELIEVE
BLVD. (REFER TO ELECTRICAL DRAWINGS - LIGHT FIXTURE
SCHEDULE)
RECESSED LED DOWN EMERGENCY NIGHT LIGHT FIXTURE WITH
BATTERY BACK-UP AT UPPER LEVEL MAKE BELIEVE BLVD. (REFER
TO ELECTRICAL DRAWINGS - LIGHT FIXTURE SCHEDULE)
RECESSED LED DOWN LIGHT. (REFER TO ELEC. DRAWINGS - LIGHT
FIXTURE SCHEDULE).
RECESSED LED DOWN EMERGENCY NIGHT LIGHT FIXTURE WITH
BATTERY BACK-UP. (REFER TO ELEC. DRAWINGS - LIGHT FIXTURE
SCHEDULE).
WALL MOUNTED SCONCE. MOUNT @42" A.F.F. SEE M.B.B. LOWER
LEVEL LIGHTING PLAN THIS PAGE.
RECESSED LED DOWN LIGHT (REFER TO ELECTRICAL DRAWINGS -
LIGHT FIXTURE SCHEDULE)
RECESSED EXTERIOR DOWN LIGHT (REFER TO ELECTRICAL
DRAWINGS - LIGHT FIXTURE SCHEDULE)
EXTERIOR WALL MOUNTED LED EXIT LIGHT FIXTURE WITH DUAL
EMERGENCY LAMPS. TO BE MOUNTED OVER THE MAIN ENTRANCE
@ 9'-6" A.F.F. AND ALL OTHER EXTERIOR DOORS @ 9'-0" A.F.F.
(REFER TO ELECTRICAL DRAWINGS - LIGHT FIXTURE SCHEDULE)
FIXTURE FINISH TO BE WHITE.
CEILING MOUNTED ILLUMINATED EXIT SIGN WITH BATTERY
BACK-UP. SHADING INDICATES ILLUMINATED FACE AND ARROW
INDICATES DIRECTION OF EGRESS. MOUNT ON UNDERSIDE OF
SOFFIT AS REQUIRED FOR INTENDED VISIBILITY
WB
#
#
REFLECTED CEILING - LEGEND:
PRE SCHOOL #3
110
PRE SCHOOL #2
112
TOILET
111
TOILET
115
TOILET
113
PRE SCHOOL #1
114
TODDLERS A
116
TOILET
117
TOILET
119
TODDLERS B
118
LOUNGE
122
LAUNDRY
121
PANTRY
120
ELEC
125
TOILET
124
INFANTS A
123
INFANTS B
126
MECH
128
TOILET
127
TWADDLERS
129
TOILET
131
TOILET
130
PRE-K-K
132
OFFICE
102
VESTIBULE
100
RECEPTION
101
CL.
103
ISO
104
CORRIDOR
133
PREPPERS A / MBB
105
PREPPERS B
109
TOILET
106
TOILET
108
TOILET
107
NL/
EM
NL/EM NL/EMNL/EM
NL/EM
NL/EM NL/EM
NL/EM
NL/
EM
NL/
EM
NL/
EM
NL/EM
NL/EM
NL/EM
NL/EM NL/EM NL/EM NL/EM
NL/EM
NL/EM
NL/EM
NL/EM
NL/EM
NL/EM
NL/EM
NL/EM
NL/EMNL/EM
2
5
9'-0"
1
A-021
3
NL/EM
NL/EM
NL/
EM
NL/EM
NL/EM
NL/EM
NL
/EM
3
4
NL/
EM
NL/
EM
NL/EM
9'-10"
WB
A-061
2
A-061
1
A-081
5
A-081
6
7 7 7 7
6
NL/EM
WB
NL/EM
1. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL WORK
ABOVE CEILING AND SHALL NOTIFY ARCHITECT OF ANY CONFLICTS
PRIOR TO INSTALLATION OF CEILING GRID, GYPSUM BOARD CEILINGS
AND SOFFITS.
2. REFER TO SHEET A-042 - FINISH PLAN FOR GYPSUM BOARD CEILINGS
AND SOFFITS
3. ALL CEILING HEIGHTS SHALL BE +9'-0" AFF UNLESS NOTED OTHERWISE
4. ALL SUSPENDED CEILING GRIDS SHALL BE DESIGNED TO RESIST
SEISMIC FORCE (FP) AS PER INTERNATIONAL BUILDING CODE, LATEST
EDITION. REFER TO DETAIL 2/A-021 FOR CEILING GRID HANGER DETAIL.
5. REFER TO ENGINEERING DRAWINGS FOR MECHANICAL, ELECTRICAL,
PLUMBING AND FIRE ALARM/SPRINKLER LAYOUTS, DETAILS AND
SCHEDULES
6. REFER TO SPECIFICATIONS FOR ALL SWITCHES, LIGHTING FIXTURES
AND EXIT SIGNS - REVISIT THIS COMMENT AFTER REVIEWING T-200
TO T-400 SPEC PAGES
7. CONTRACTOR SHALL VERIFY AND CONFIRM ALL LIGHT FIXTURES ARE IN
WORKING CONDITION WITH OPERABLE LAMPS
REFLECTED CEILING - GENERAL NOTES:
CEILING TILES TO BE INSTALLED W/ RETAINING CLIPS AT VESTIBULE
BUILDING SIGNAGE. REFER TO DETAILS ON DRAWING A-161.
36"x36" ROOF ACCESS HATCH AND LADDER SHALL BE KEPT CLEAR OF
ALL DUCTS, WIRE, CONDUITS, OR OTHER FIXED ITEMS. SEE DETAILS
ON SHEET A-032
MECHANICAL ROOM TO RECEIVE (1) LAYER OF GYP FASTENED TO
UNDERSIDE OF TRUSSES AND (1) LAYER OF GYP FASTENED TO
VERTICAL FACES OF ROOF ACCESS SHAFT. SEE DETAILS ON SHEET
A-032
5" SOFFIT @ 7'-0 1/2" A.F.F. ABOVE REFRIGERATOR & FREEZER. REFER
TO DETAIL 3/A-021.
ENTRY CANOPY
TYPICAL CANOPY
1
2
3
4
5
REFLECTED CEILING - KEY NOTES:
6
7
CEILING GRID AND TILE TO BE
INSTALLED PER ASTM C 636.
PERIMETER HANGER WIRES
TO BE PLUMB WITH 1
IN 6 UNLESS COUNTER
SLOPING WIRES ARE
PROVIDED
SUPPORT AT WALL
PER ASTM C 636
HANGER WIRES TO BE
12 GA. GALVANIZED
SOFT-ANNEALED, MILD
STEEL WIRE PER ASTM
C 636 SECTION 2.1.6.
WIRE TO BE SPACED AT
4' O.C. MAX. OR 10 GA.
AT 5' O.C. MAX (TYP.)
CONNECT TO
STRUCTURE ABOVE
USING 'HILTI X-CC' OR
APPROVED EQUAL. ALL
WIRE TIES TO BE
THREE TIGHT TURNS
AROUND ITSELF
WITHIN 3" (TYP.)
CEILING GRID AND
TILE AS SPECIFIED
STRUCTURE ABOVE
CORNER BEAD
1 LAYER OF
5
8
" GYP. BD.
ON EACH SIDE
B.O. SOFFIT
7'-0 1/2" A.F.F.
SUSPENDED CEILING
9'-0" A.F.F.
6"
MIN
MTL STUDS @ 16" O.C.
REFLECTED
CEILING PLAN
A-021
NORTH
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
21
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
SCALE:
1
REFLECTED CEILING PLAN
1/8"=1'-0"
SCALE:
2
CEILING GRID HANGERS DETAIL
NOT TO SCALE
SCALE:
3
SOFFIT DETAIL @ PANTRY
1"= 1'-0"
SV | KT
EF-2
EF-1
RTU-1RTU-2RTU-3RTU-4RTU-5
66'-0"
22'-10"
22'-4" 22'-1"22'-4"
SL
OP
E 1/4
":12
"
SL
OP
E 1/4
":1
2"
20 GA. GALV. MTL.
DOWNSPOUT W/GALV.
MTL. SLEEVE (TYP.)
A051
3
A051
4
A051
2
A051
1
ROOF LADDER ACCESS
SEE 8/A-032 FOR DETAIL
26'-3"
19'-3"40'-1"19'-9"19'-11"33'-4"
42'-10"22'-2"
A061
1
A061
2
AWNING AT
PLAY AREA
BELOW
A-071
2
A-071
1
MANUFACTURER'S
PROTECTIVE WALKWAY
PADS
24'-5"23'-2"20'-3"44'-11"
15'-5"
A-032
4
A-032
1
AWNING AT
PLAY AREA
BELOW
4'-0" 4'-0"4'-0"
60 MIL TPO ROOF SYSTEM BY GAF (OR
APPROVED EQUAL) ON RIGID INSULATION
(R-20 MIN.). TAPER INSULATION AT
CRICKETS TO ROOF DOWNSPOUT
LOCATIONS PER THIS DRAWING.- SEE
SPECIFICATIONS.
BILCO ROOF HATCH
36"X 36" W/CURB &FLASHING.
PROVIDE LADDER UP SAFETY
POST; SLOPE ROOF AWAY
FROM HATCH- SEE SHELL
DRAWINGS
5'-0
"
11'-6"
EF-3EF-4
20 GA. GALV. MTL.
OVERFLOW SCUPPER
(TYP.)
DRYER EXHAUST DUCT;
REF MECHANICAL
GENERAL NOTES: LEGEND:
1. GENERAL CONTRACTOR SHALL FIELD VERIFY CONDITIONS AND NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
2. REFER TO SPECIFICATIONS DRAWINGS FOR ADDITIONAL INFORMATION FOR ROOFING,
FLASHING REQUIREMENTS, AND MATERIALS.
3. PRIMARY ROOF SCUPPERS MUST CONNECT TO UNDERGROUND STORM SYSTEM.
DOWNSPOUTS MUST DROP THRU SIDEWALK TO CONNECT TO UNDERGROUND STORM
SYSTEM. SEE CIVIL.
4. VERIFY AND COORDINATE DUCT CURB AND ROOF PENETRATION LOCATIONS; REFER TO THE
MECHANICAL/ ELECTRICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS AND COORDINATION.
5. PLUMBING VENTS OR EXHAUST VENTS ARE NOT ALLOWED WITHIN 10'-0" OF AIR INTAKES OR
5'-0" OF EXTERIOR WALLS- REFER TO MECH. DRAWINGS.
6. ALL SHEET METAL FLASHING TO COMPLY WITH THE "ARCHITECTURAL SHEET METAL MANUAL",
2012 EDITION AS PUBLISHED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTIONS
NATIONAL ASSOCIATION (SMACNA).
7. ALL SHEET METAL FLASHING EXPOSED TO THE PUBLIC SHALL BE PAINTED OR PREFINISHED.
SEE BUILDING ELEVATIONS FOR COLOR SPECIFICATIONS. ALL OTHER NON EXPOSED
FLASHING TO BE GALVANIZED.
8. ALL EXHAUST FANS AND VTR'S SHALL EXTEND ABOVE ROOF PARAPET TO ENSURE EXHAUST
FUMES NOT BE CONTAINED AND TO PREVENT FROM ENTERING THE HAVC FRESH AIR INTAKES.
9. UPON COMPLETION OF CONSTRUCTION AND PRIOR TO TENANT OCCUPANCY, G.C. SHALL
ENSURE THAT THE ENTIRE ROOF, ALL GUTTERS, ROOF SCUPPERS/ DOWNSPOUTS, AND
OVERFLOW SCUPPERS ARE COMPLETELY CLEAR OF ANY AND ALL DEBRIS (CONSTRUCTION,
NATURAL, OR OTHERWISE).
10.ROOFING SUBMITTAL TO INCLUDE PRODUCT APPROVALS WITH ALL SPECIFIC PROJECT
DETAILS AND INSTALLATION INDICATED CLEARLY FOR A/E REVIEW. INDICATE WIND LOAD/
UPLIFT MEETING PROJECT DESIGN LOADS.
10.1. APPROVED ROOF MANUFACTURERS INCLUDE: GAF, FIRESTONE, AND CARLISLE
AREA TO RECEIVE- WALKWAY PADS
BASE BID FOR WALKWAY PADS TO BE ON ALL FOUR
SIDES OF HVAC EQUIPMENT
BID ADD ALTERNATE TO INCLUDE
INTERCONNECTING PADS
BETWEEN UNITS AND FOR ACCESS TO ROOF
LADDER
AREA TO RECEIVE SINGLE PLY ROOFING
MEMEBRANE
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
31
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
NORTH
ROOF PLAN
A-031
SCALE:
1
ROOF PLAN
1/8"=1'-0"
SV | KT
1
K
K
K
K
K K
K
K K
K
K
K
K
K K
K
K
K
K
K
K
K K
K
K
K K
K
1'-9
"3
'-6
"1
'-9
"
1'-9"8'-0" 1'-9"1'-9"
3
2
SP
K
SP
K
SP
K
SP
KL L
V V
V V
V
V
V
V
V
V
V V
V
V
V
V
V
V
V V
V
V
V
V
V
V
V
VV
V
V V
V V
V
V
V V
V
V
V
V
V
V
V V
V
V
V
V
V
V
V
VV
V
VV
VV
VV
V
V
V
V
VV
V
V
VV
V
V
VV
V
V
V
V
V
V
V
V V
V
VV
VV
VV
VV
V
V
VV
V
V
VV
V
V
V
V
V
V
V
V V
V
OFFICE
102
VESTIBULE
100
RECEPTION
101
ISO
104
V
VV
VV
VV
V
L
L
1'-9"
B
B B B
VV
VV
VV
VV
K
K
K
K
K
K
K
K
K
K
K
K
K K
K
K
K K
K
K
K
K K
K
K
K
K
K
K
K K
K
K K
K
K
K
K
K K
K
K
K
K
K K
K
K
K K
K
K
K
K
K
K
K
K K
K
K K
K
K
K
K
K K
K
K
K
K
K K
K
K
K K
K
K
K
K
K
K
K
K
K
K
K
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
V V
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
VV
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SPSP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SPSP
KKKKKK
K
K
K
K
KKKKKK
K
K
K
K B
B
B
BBBB
B
B
B B B
S
SS
S
L
SP
V
L
L
L
L
LLLLLL
L
L
L
L
L L L L L
SPSPSP
SP
SP
SP SP SP SP
SP
SPV
V V
S
S
S
S
S
SSSSSS
S
S
S
S
S S S S S
K
K
K
KKKK
K
K
K K K
B B
BB
SP
SP
SP
SP
SP
SPSPSPSPSPSP
SP
SP
SP
SP
SP SP SP SP SP
V
V
V
VVVV
V
V
V V V
L L
LL
BBBBBB
B
B
B
B
B
B
B
B
BBBBBB
SSSS
S
S
S S S S
S
SK K
KK
V
V
VVVVV
V
V
V
V
V V V V V V
V
V
V
L L L L
L
L
LLLL
L
L SP SP
SPSP
KKKKKK
K
K
K
K
KKKKKK
K
K
K
K B
B
B
BBBB
B
B
B B B
S
SS
S
V
V
VVVVV
V
V
V
V
V V V V V V
V
V
V
L L L L
L
L
LLLL
L
L SP SP
SPSP
BBBBBB
B
B
B
B
B
B
B
B
BBBBBB
SSSS
S
S
S S S S
S
SK K
KK
B
B B
B
B B
BB
B
B B
B
V V
VV
V V
VV
V V
VV
V
V V
V
V
V V
V
B
B B
B
B B
BB
B
B B
B
B B
BBV
V V
V
V
V V
V
V
V V
V
V
V V
V
V
V V
V
V
V V
VB B
BB
B B
BB
B B
BB
B B
BB
BB
B
B B
B
B
B B
B
B BV V
V
V V
V
VB B V
V VB B VB B V
V VBB BB
V
V V
VB B
BB
B B
BBV
V V
V
B B
BBV
V V
V
B B
BB
B B
BBV
V V
V V
V V
V
B B
BB
B
B B
B
V
V V
V
B
B B
B B
B B
B
V
V V
V V
V V
V
B
B B
B
V V
VV
V V
VV
V V
VVB
B B
B
B
B B
B
B BV V
L L L L
L
L
LLLL
L
L
V V
VV
V
V
V
V V V V
V
V
VVV
L
L L
L
L L L L
L
L
LLLL
L
L
V V
VV
V
V
V
V V V V
V
V
VVV
L
L L
L
L L L L
L
L
LLLL
L
L
V V
VV
B B
B B
B
B
BB
B B
B
B
B B
BB
B
B
B
BB
B
B
B
B
BB
B
B
B
B
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
BB
B B
B
B
B
B
B
B
B B
BB
B
B
B
B B
B
B
B
B
B
B
B B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B B
B B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
K K K K K K K K K K K K K K K K K K K K K K
KKKKKKKKKKKKKKKKKKKKKK
K
K
K
K
K
K
K
K
K
K
K
K
K
KK
K
K
K
K
K
K
K
K
K
K
K
K
K
K K K K K K K K K K K K K K K K K K
K K K K K K K K K K K K K K K K K K
K
K
K
K
K
K
K
K
K
K
K
K
B
B
B
B
B B B B B B B
B
B
B
BB
B
B
B B B B B B B B
B
B
L L L L L L
L
L
L
L
LLLLLL
L
L
L
L
PRE SCHOOL #3
110
PRE SCHOOL #2
112
TOILET
111
TOILET
115
TOILET
113
PRE SCHOOL #1
114
TODDLERS A
116
TOILET
117
TOILET
119
TODDLERS B
118
LOUNGE
122
LAUNDRY
121
PANTRY
120
ELEC
125
TOILET
124
INFANTS A
123
INFANTS B
126
MECH
128
TOILET
127
TWADDLERS
129
TOILET
131
TOILET
130
PRE-K-K
132
OFFICE
102
CL.
103
CORRIDOR
133
PREPPERS A / MBB
105
PREPPERS B
109
TOILET
106
TOILET
108
TOILET
107
FD-1
GT-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
EQ EQ
4'-3
"
FLOOR FINISH LEGEND
INDICATE CHANGE IN FLOOR FINISH
VINYL COMPOSITION TILE (VCT) -
12x12" VINYL COMPOSITION FLOOR TILE (VCT)
REFER TO FLOOR FINISH SCHEDULE AND SPECIFICATIONS
BLANK TILES REPRESENT STANDARD COLOR THROUGHOUT
THE BUILDING. LETTERED TILES REPRESENT VARIOUS
COLORS USED FOR PATTERNS
QUARRY TILE: 6"X6" PATTERNED FACE
REFER TO FLOOR FINISH SCHEDULE AND SPECIFICATIONS
VINYL FLOORING
SOLID SHEET WITH NO SEAMS, 6" COVE BASE
REFER TO FLOOR FINISH SCHEDULE AND SPECIFICATIONS
CONCRETE FLOOR -
CONCRETE FLOOR PAINTED GRAY WITH VINYL BASE
CARPET
FLOOR DRAIN -
SEE PLUMBING DRAWINGS
GREASE TRAP -
SEE PLUMBING DRAWINGS
NOTE - SEE FLOOR FINISH SCHEDULE ON THIS PAGE FOR
CARPET AND TILE SPECIFICATIONS, INCLUDING LIST OF
COLORS.
FD-1
GT-1
FLOOR FINISH SCHEDULE
VINYL COMPOSITION FLOOR TILE (VCT):
MANUFACTURER: ARMSTRONG
TYPE: STANDARD EXCELON RAVE
SIZE: 12 IN. WIDE X 12 IN. LENGTH X
1
8
IN. THICKNESS
COLOR AND PATTERN: PROVIDE THE FOLLOWING IN LOCATIONS AS
DEPICTED ON THE DRAWINGS:
1. (W) WHITE OUT - 57518
2. (SP) SCREAMING PUMPKIN - 57516
3. (S) SHOCKING - 57514
4. (B) BIKINI BLUE - 57512
5. (L) LEMON LICK - 57509
6. (V) VICIOUS VIOLET - 57513
7. (K) KICKIN KIWI - 57510
8. BLACK #1 - 56790 (PREPPERS A / MBB)
9. (G) GRABBIN GREEN - 57511 (PREPPERS A / MBB)
ADHESIVE: S-725, WATER-RESISTANT TYPE PER MANUF.
RECOMMENDATION FOR PRODUCTS AND
SUBSTRATE
FIRE DEST DATA: ASTM E 662 SMOKE DEVELOPMENT 450 OR LESS
REFERENCE SPEC: ASTM 1066 CLASS 2 - THROUGH-PATTERN
CLEANING: VCT - IMMEDIATELY AFTER INSTALLATION, VCT SHALL BE
PROPERLY CLEANED WITH A NEUTRAL DETERGENT SOLUTION SUCH AS
ARMSTRONG S-485 COMMERCIAL FLOOR CLEANER AS PER
MANUFACTURER'S RECOMMENDATIONS/INSTRUCTIONS. VCT TO
RECEIVE HIGH QUALITY STAIN RESISTANT SEALER SUCH AS
ARMSTRONG S-495 COMMERCIAL FLOOR POLISH. AT FINAL CLEAN
PROPERLY CLEAN VCT AS PER MANUFACTURERS
RECOMMENDATIONS/INSTRUCTIONS INCLUDING THE USE OF STRIPPING
SOLUTION SUCH AS ARMSTRONG S-490 COMMERCIAL FLOOR STRIPPER.
APPLY SPECIFIED FLOOR SEALER AND (5) TO (7) COATS OF SPECIFIED
FLOOR POLISH. POLISH TO HIGH GLOSS SHINE.
SHEET VINYL FLOOR COVERING:
MANUFACTURER: SHAW
COLLECTION: VITALITY SHEET
COLOR: BENEFIT 73415
PRODUCT #: 0873V
SHEET WIDTH: AS STANDARD WITH MANUFACTURER; 12 FT.
WALL BASE: TURN UP SHEET VINYL 6" AT ALL WALLS TO
CREATE INTEGRAL COVE BASE
ACCESSORIES: CONTINUOUS BONDED PUNCTURE-PROOF
ALUMINUM REINFORCEMENT STRIP (FULL
ROOM PERIMETER)
NOTES:
1. HOMOGENOUS SHEET
2. TO BE COMMERCIAL-GRADE. INSTALL WITH NO SEAMS
3. INTEGRAL COVE BASE RADIUS SHALL NOT EXCEED 1/2" WHERE
THE WALL MEETS THE FLOOR
TO BE INSTALLED: TOILETS AND LAUNDRY ROOM
QUARRY FLOOR TILE:
MANUFACTURER: DALTILE
TYPE: INTERIOR TYPE BODY, FLAT TILE
BASE: COVED, COLOR TO MATCH FLOOR TILE
COLOR: ARID GREY
GROUT: LATICRETE
GROUT COLOR: #57 HOT COCOA
CATALOG #: 0Q42
FACE: 6"x6" PATTERNED FACE WITH STANDARD EDGE
THICKNESS: 5/16"
TO BE INSTALLED: PANTRY
RESILIENT WALL BASE AND ACCESSORIES:
MANUFACTURER: JOHNSONITE
TYPE: 4" TRADITIONAL VINYL (WITH TOE)
COLORS: 18, NAVY BLUE
162, SOVEREIGN
MIN. THICKNESS: 0.080" (2.0 mm), 0.125" (3.2 mm)
LENGTHS: MANUFACTURER'S STANDARD COILS
FIRE RATING: CLASS B
TO BE INSTALLED:
NAVY BLUE - ALL WALLS UNLESS OTHERWISE NOTED
SOVEREIGN - INDOOR PLAY AREA (IF APPLICABLE) FULL
PERIMETER AND FREESTANDING COLUMNS
CONCRETE FLOOR:
MANUFACTURER: COROTECH (BENJAMIN MOORE)
TYPE: WATERBORNE AMINE EPOXY V440
COLORS: BATTLESHIP GRAY (75)
PINK RASPBERRY (2075-40)
INSTALLATION: FULL COVERAGE; APPLY MIN. TWO (2) COATS
TO BE INSTALLED:
BATTLESHIP GRAY (75) - ELECTRICAL CLOSET, JANITOR'S
CLOSET, AND MECHANICAL ROOM
PINK RASPBERRY (2075-40) - INDOOR PLAY AREA (IF
APPLICABLE) FULL EXTENTS OF UNITY
SURFACING
CARPET: (REQUIRED)
MANUFACTURER: INTERFACE
CONTACT: GLENDA KISNER
PHONE: 305.710.5105
EMAIL: [email protected]
STOCK HOLD: #3141
IDENTIFICATION #: CONTACT REQUIRED VENDOR
FIRE RATING: CLASS A
FIRE TESTING: FLOORING RADIANT PANEL (ASTM E-648) PASSES
SMOKE DENSITY (ASTM E-662) ≤ 450
FLAMMABILITY / PILL TEST (DOC-FF1-70) PASSES
OFFICE & CLASSROOM CARPET (REQUIRED):
CARPET TYPE: CARPET TILES, GLASBAC
PRODUCT NAME & #: GATHER 19DR402500
COLOR: 180784 MARINE ACCENT
TO BE INSTALLED: IN OFFICE AND ALL CLASSROOMS (NOT
INFANT) PER PLAN
TO BE INSTALLED: QUARTER TURN
TO BE INSTALLED: xL2000 DIRECT GLUE DOWN METHOD
K
S
V
B
L
G
BK
SP
1. GENERAL CONTRACTOR SHALL FIELD VERIFY CONDITIONS
AND NOTIFY ARCHITECT OF ANY DISCREPANCIES.
2. ALL FLOORS SHALL BE PROPERLY PREPARED AND SKIM
COATED AS NECESSARY TO ACHIEVE CLEAN SURFACES SO
THAT BLEMISHES DO NOT TELEGRAPH THROUGH FINISH
MATERIAL.
3. CONTRACTOR SHALL SUBMIT SAMPLES OF ANY ALTERNATE
FINISHES TO ARCHITECT FOR APPROVAL PRIOR TO
ORDERING MATERIALS. SEE SPECIFICATIONS DRAWINGS
FOR SUBMITTAL PROCEDURE.
4. PROVIDE RUBBER TRANSITION STRIP AT JUNCTION OF
CARPET AND VCT. REFER TO DOOR AND HARDWARE
SCHEDULE FOR FURTHER INFORMATION.
5. ALL FLOOR FINISH CHANGES AT DOORWAYS SHALL BE
CENTERED UNDER DOOR. PATTERN TO BE CENTERED
UNDER DOOR.
6. CARPET TO BE INSTALLED AT END OF CONSTRUCTION AND
PROTECTED FROM ANY DEBRIS. CARPETS TO BE
THOROUGHLY VACUUMED AT THE COMPLETION OF
CONSTRUCTION.
7. ALL UNLABELED FLOOR FINISHES TO BE ARMSTRONG,
STANDARD EXCELON RAVE, (W) WHITE OUT - 57518, UNLESS
OTHERWISE NOTED.
8. ALL VCT FLOORS TO BE WAXED MIN. 5 COATS WITH
ARMSTRONG S-495 COMMERCIAL FLOOR POLISH.
9. REFER TO A-121 FOR TRANSITION DETAILS
FLOOR FINISH GENERAL NOTES:FLOOR FINISH KEY NOTES
PROVIDE WALK-OFF MAT - SEE FLOOR FINISH SCHEDULE
FOR SPECIFICATIONS
RECEPTION AREA CUSTOM VCT LOGO SHALL BE
PURCHASED FROM REQUIRED CARPET VENDOR. REFER
TO CONTACT INFORMATION.
PREPPERS A / MBB RACETRACK:
· CENTER OVAL: VCT COLOR "G" (PER FINISH SCHED.)
· ROADWAY: VCT COLOR "BLACK #1" (PER FINISH
SCHED.)
· LANE STRIPING: VCT COLOR "L" (PER FINISH SCHED),
APPROX. 1" WIDE BY 6" LONG WITH A 3" SPACE
BETWEEN EACH STRIPE
1
2
3
INTERIOR FINISH TESTING REQUIREMENTS:
1. CARPET, PADDING, WALK-OFF MAT, AND ANY OTHER
FIBER-BASED FLOOR FINISHES SHALL BE CLASS 1 OR CLASS
II AS TESTED PER NFPA 253.
2. WALL BASE FINISHES (6"H OR LESS) SHALL BE CLASS I OR
CLASS II AS TESTED PER NFPA 253.
3. FLAME SPREAD INDEX AND SMOKE DEVELOPED RATING:
· WALL AND CEILING FINISH MATERIALS SHALL BE MINIMUM
CLASS B:
FLAME SPREAD: < 75
SMOKE DEVELOPED INDEX: < 450
· INTERIOR TRIM MATERIALS SHALL BE MINIMUM CLASS C:
FLAME SPREAD: < 200
SMOKE DEVELOPED INDEX: < 450
INFANT ROOMS ONLY CARPET(REQUIRED):
CARPET TYPE: CARPET TILES, CUSHION BAC RENEW
PRODUCT NAME & #: GATHER 19DR402500
COLOR: 180784 MARINE ACCENT
TO BE INSTALLED: IN ALL INFANT CLASSROOMS PER PLAN
TO BE INSTALLED: QUARTER TURN
TO BE INSTALLED: xL2000 DIRECT GLUE DOWN METHOD
WALK-OFF MAT:
MANUFACTURER: AMARCO
STYLE: INDIVIDUAL 24" TILES, 1/4 TURN
COLOR: STEEL BLUE #64
FIRE TEST DATA: ASTM D2859- PILL TEST (SURFACE
FLAMMABILITY)
TO BE INSTALLED: VESTIBULE
TRANSITION STRIPS:
DESCRIPTION: REFER TO SHEET A-121 FOR MORE
INFORMATION.
COLOR: TO MATCH VINYL COVE BASE.
NOTE:
TLE VCT LOGO & MBB RACETRACK CARPET MUST BE PURCHASED FROM
REQUIRED VENDOR. NO SUBSTITUTIONS ALLOWED.
SHEHADI COMMERCIAL CARPET & FLOORING
ATTN: GEORGE SKURCHAK
23 JUST ROAD PH. 973-808-4443 EXT. 13
FAIRFIELD, NJ 07004 FAX. 973-808-4493
FLOOR FINISH
PLAN
A-041
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
41
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
NORTH SCALE:
1
FLOOR FINISH PLAN
1/8"=1'-0"
KT
456
MA
KE
BE
LIE
VE
BLV
D.
GA
RA
GE
DIN
ER
GE
NE
RA
L
ST
OR
E
FIRE
STATION
BC-12 BC-12
BC
-8
BC-8
BC
-8
BC-8BC-10BC-10
BC-10BC-10 BC-8BC-8BC-10
BS
-1
0
BC-8
BC
-8
BC
-8
BC-10BC-10
BC-10
BS
-1
0
BC-8
PRE SCHOOL #3
110
PRE SCHOOL #2
112
TOILET
111
TOILET
115
TOILET
113
PRE SCHOOL #1
114
TODDLERS A
116
TOILET
117
TOILET
119
TODDLERS B
118
LOUNGE
122
LAUNDRY
121
PANTRY
120
ELEC
125
TOILET
124
INFANTS A
123
INFANTS B
126
MECH
128
TOILET
127
TWADDLERS
129
TOILET
131
TOILET
130
PRE-K-K
132
OFFICE
102
VESTIBULE
100
RECEPTION
101
CL.
103
ISO
104
CORRIDOR
133
PREPPERS A / MBB
105
PREPPERS B
109
TOILET
106
TOILET
108
TOILET
107
BS
-1
0
BC-10
4 4
4
4
4
C
A
AH
M
H
M
A
M D
C
D
H
AH
C
C
M
HAM
D
MA
C
A
H
DA
M
C
D
2
3
D
D
M
H
M
C
A
D
1
1
D
A
M
M
A
M
H
M
A
C
AH
CM
AH
H
MAC
A
M
A
H
D
M
C
D
4
4
4
4
4
4
4
PAINT FINISH SCHEDULE
FINISH
CODE
COLOR
BENJAMIN MOORE SHERWIN WILLIAMS PPG PAINTS
COLOR NAME STOCK NO. COLOR NAME STOCK NO. COLOR NAME STOCK NO.
W WHITE WHITE DOVE OC 17 GREEK VILLA 7551 WHITE DOVE CM BM
M ORANGE MANGO PUNCH 154 OSAGE ORANGE 6890 OSAGE ORANGE CM SW
H PURPLE HYDRANGEA 1390 BERRY FRAPPE 9068 BERRY FRAPPE CM SW
D YELLOW VIKING YELLOW 321 CHEERFUL 6903 FLIRTATIOUS 1212-7
C GREEN CANDY GREEN 403 PRIMAVERA 9031 GOODY GUMDROP 1219-4
A BLUE ATLANTIS BLUE 768 FOUNTAIN 6787 FOUNTAIN CM SW
PAINT FINISH SCHEDULE NOTES:
1. PAINT FINISH:
a. H.M. DOOR AND WINDOW FRAMES SHALL BE SEMI-GLOSS FINISH.
b. ALL OTHER PAINT SHALL BE EGGSHELL FINISH.
c. ALL STOREFRONT (ALUMINUM/GLASS) DOORS SHALL BE FINISHED PER DOOR SCHEDULE (SHEET A-121)
2. ALL PAINTED SURFACES SHALL RECEIVE MINIMUM ONE COAT OF PRIMER AND TWO COATS OF PAINT
(UNLESS FACTORY PRIMED BY THE MANUFACTURER). REFER TO SPECIFICATIONS DRAWINGS FOR
ADDITIONAL INFORMATION.
3. SELECTED COLOR PALETTE SHALL BE FROM ONE OF THE ABOVE MANUFACTURERS.
4. NO SUBSTITUTIONS WILL BE ALLOWED.
"CM BM" = COLOR MATCH BENJAMIN MOORE
"CM SW" = COLOR MATCH SHERWIN WILLIAMS
*
W
SUSPENDED
CEILING
*
W
3'-1
0"
REFER TO A-012 FOR WIDTH
VARIES
W = PER PAINT FINISH SCHEDULE
* = COLOR DESIGNATED ON PAINT FINISH PLAN
ALSO REFER TO GENERAL NOTE #5
30'-0" MAX. BETWEEN DRYWALL CONTROL JOINTS
DRYWALL CONTROL
JOINT ALIGNED WITH
DOOR JAMB (REF. A-011)
DRYWALL CONTROL JOINT
ALIGNED WITH WINDOW
JAMB (REF. A-011)
PAINT FINISH LEGEND:
W
W
W
DOOR AND FRAME - BOTH SIDES
INTERIOR WINDOW AND FRAME- BOTH SIDES
WALL AND GYPSUM BOARD SOFFIT
WALL FINISH GENERAL NOTES:
1. PRIOR TO COMMENCEMENT OF PAINTING, THE GC. SHALL BE RESPONSIBLE FOR THE
FOLLOWING:
a. FIELD VERIFY THAT ALL SURFACES ARE READY TO ACCEPT PAINTS- NOTIFY
ARCHITECT OF ANY DISCREPANCIES
b. REMOVE OR PROTECT ALL ELECTRIC SWITCHES, OUTLETS, PLATES, SURFACE
HARDWARE, ETC.
c. GC. TO PROTECT ALL ADJACENT SURFACES AS REQUIRED DURING PAINTING.
2. CONTRACTOR SHALL SUPPLY ALL PAINT AND MATERIALS AS PER PAINT FINISH SCHEDULE
AND PAINT FINISH LEGEND. ALL PAINT AND MATERIAL MUST BE DELIVERED TO THE JOB
SITE IN THE MANUFACTURER'S ORIGINAL PACKAGING- NO SUBSTITUTIONS ALLOWED.
3. ALL HOLLOW METAL DOORS, DOOR FRAMES, AND INTERIOR WINDOW FRAMES ARE TO BE
FACTORY PRIMED AND FIELD PAINTED ON BOTH SIDES.
a. INTERIOR DOORS, DOOR FRAMES, AND INTERIOR WINDOW FRAMES SHALL BE
PAINTED THE SAME COLOR ON BOTH SIDES UNLESS OTHERWISE INDICATED ON
FINISH PLAN.
4. AREAS LISTED BELOW TO BE PAINTED WITH ONE PRIMER COAT AND TWO FINISH COATS
OF "W" ON PAINT FINISH LEGEND AND SCHEDULE
a. CLOSET INTERIOR WALLS
b. TOILET INTERIOR WALLS
c. MECHANICAL ROOM INTERIOR WALLS
d. ALL SURFACES, UNLESS NOTED OTHERWISE.
e. GYPSUM SOFFIT (ALL SIDES) UNLESS NOTED OTHERWISE
5. ALL WALLS TO BE PAINTED AS PER PAINT FINISH SCHEDULE UNLESS NOTED OTHERWISE.
6. CORRIDOR WALLS: REFER TO CORRIDOR FINISH DETAIL 2/A-042.
7. PREPPERS A / MBB: ALL WALLS ARE TO BE PAINTED "W" AS PER PAINT FINISH SCHEDULE.
PREPPERS A / MBB FACADE MANUFACTURER SHALL PROVIDE FACADE AND A TOUCH-UP
KIT WITH ALL NECESSARY COLORS IN SEMI GLOSS FINISH.
8. ALL FINISH WORK SHALL BE APPLIED FREE OF SAGS, RUNS, STREAKS, BRUSH OR ROLLER
MARKS ETC.
9. UPON COMPLETION, THE GENERAL CONTRACTOR SHALL
a. REMOVE ALL PAINT FROM WHERE IT HAS SPILLED, SPLASHED, OR SPLATTERED ON
SURFACES, INCLUDING LIGHT FIXTURES, DIFFUSERS, SLAB FITTINGS, ETC.,
b. REINSTALL AND/OR REPLACE ANY DAMAGED ELECTRIC SWITCHES, OUTLETS,
PLATES, SURFACE HARDWARE, ETC. AFTER PAINT COMPLETION.
CHAIR RAIL TO BE PAINTED "W" PER PAINT FINISH SCHEDULE.
WALL FINISH KEY NOTES
1
2
3
4
IN PANTRY, ALL WALLS INCLUDING SPLASH AREAS ABOVE COUNTER, TO
RECEIVE F.R.P. TO 7'-6" A.F.F., REFER TO WALL FINISH SCHEDULE (THIS PAGE)
AND PANTRY DETAILS A-133 FOR ADDITIONAL INFORMATION.
FRP TO BE INSTALLED IN LAUNDRY ROOM AND JANITOR'S CLOSET ON WALL
BEHIND SINK AND 3' EACH SIDE OF SINK TO 7'-6" A.F.F. REFER TO WALL FINISH
SCHEDULE (THIS PAGE).
FRP TO BE INSTALLED IN TOILET ROOMS ON WET WALL(S) AND ADJACENT
WALL(S) TO A MINIMUM HEIGHT OF 4'-4" A.F.F. REFER TO WALL FINISH
SCHEDULE (THIS PAGE).
FIBERGLASS REINFORCED PLASTIC PANELS (FRP):
MANUFACTURER: CRANE COMPOSITES
PRODUCT: KEMPLY FIBERGLASS LAMINATED WALL PANEL
PRODUCT CODE: KEM
FINISH: WHITE, STIPPLE
FIRE RATING: CLASS A
INTERIOR PAINT: (NO SUBSTITUTIONS ALLOWED)
MANUFACTURER: BENJAMIN MOORE
PRODUCTS:
· TYPICAL PRIMER: ULTRA SPEC INTERIOR PRIMER 534
· TYPICAL PAINT: ULTRA SPEC INTERIOR EGGSHELL 538
· WOOD: N319 REGAL SATIN/ EGGSHELL
· H.M. DOORS/FRAMES: SUPER SPEC HP P29 DTM ACRYLIC (SEMI-GLOSS)
OR
MANUFACTURER: SHERWIN WILLIAMS
PRODUCTS:
· TYPICAL PRIMER: PROMAR 200 ZERO V.O.C. PRIMER
· TYPICAL PAINT: PROMAR 200 ZERO V.O.C. INTERIOR LOW GLOSS EG-SHEL
· WOOD: PROMAR 200 ZERO V.O.C. INTERIOR LOW GLOSS EG-SHEL
· H.M. DOORS/FRAMES: PRO INDUSTRIAL DTM ACRYLIC (SEMI-GLOSS)
CARPET:
REFER TO FLOOR FINISH SCHEDULE FOR PRODUCT SPECIFICATION.
CARPET REQUIRED AT ALL FREESTANDING COLUMNS
· TO A HEIGHT OF 3'-6"
· ONLY APPLIES IF FREESTANDING COLUMNS SHOWN ON PLAN
· EXCLUDES PREPPERS B AND INDOOR PLAY AREAS
WALL FINISH SCHEDULE:
NORTH
WALL FINISH
PLAN
A-042
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
42
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
6/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
190--
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
SCALE:
1
WALL FINISH PLAN
1/8"=1'-0"
SCALE:
2
CORRIDOR FINISH DETAIL
1/8"=1'-0"
KT
LINE OF FINISH
FLOOR- 0'-0"
T.O. SILL 3'-4"
DOORS & WINDOWS
HEADERS 8'-0"
3335
OVERALL HEIGHT 20'-2"
T.O. LOWER PARAPET
OVERALL HEIGHT 23'-6"
T.O. UPPER PARAPET
B.O. TYP CANOPY 9'-4"
B.O. MAIN ENTRY
CANOPY 10'-8"
3
1
2
4
C
A
B
D
EIFS-1
CANOPY BRICKBRICKEIFS 2 EIFS 2 KNOX-1ADDRESS
STUCCO CANOPY EIFS-1
CANOPY EIFS 2
STUCCOCANOPY
HOSE BIBB
WEATHERPROOF RECEPTACLE
(TYP; REF. ELEC. DWGS.)
INTERNALLY LIT LED SIGN
35 SF - REF. 3/A-161
FIXED WINDOW
(TYP.)
KEYCODE
LOCKBOX
EIFS 2 EIFS 2 EIFS 2
BRICK
Academy of Early Education
3'-7
"
10'-0"
LINE OF FINISH
FLOOR- 0'-0"
B.O. SILL 3'-4"
DOORS & WINDOWS
HEADERS 7'-4"
OVERALL HEIGHT 20'-2"
T.O. UPPER PARAPET
HOSE BIBB
REVEALBRICK
STUCCO EIFS-1SCONCE
DRINKING FOUNTAIN
AWNING AT PLAY AREA (2 TYP.)
REFER TO A-152 FOR ADDITIONAL
INFORMATION AND DETAILS
WEATHERPROOF
RECEPTACLE (2 TYP;
REF. ELEC. DWGS.)
HOSE BIBB
4'-4
"
CALL BOX- REFER TO ELEC. DWG
FOR ADDITIONAL INFORMATION
KEY FOB- REFER TO ELEC. DWG
FOR ADDITIONAL INFORMATION
FIXED
WINDOW
(TYP.)
MTL DOWNSPOUT (TYP.)
COLOR: WHITE
±4
'-4
"
WATER PLAY CONTROL BOX;
COORDINATE WITH VENDOR
FOR EXACT LOCATION
DRINKING FOUNTAIN
WEATHERPROOF
RECEPTACLE (2 TYP;
REF. ELEC. DWGS.)
HOSE BIBB
SCJ
3'-0" 3'-0"
12
'-5
"
OVERALL HEIGHT 20'-2"
B.O. SILL 3'-4"
T.O. UPPER PARAPET
OVERALL HEIGHT 23'-6"
T.O. UPPER PARAPET
OVERALL HEIGHT 25'-6"
T.O. UPPER PARAPET
LINE OF FINISH
FLOOR- 0'-0"
DOORS & WINDOWS
HEADERS 7'-4"
B.O. TYP CANOPY 9'-4"
B.O. MAIN ENTRY
CANOPY 10'-8"
SCONCE EIFS-1
BRICK
STUCCO
STUCCO
EIFS 2REVEAL
35'-0"35'-0"
LINE OF FINISH FLOOR- 0'-0"
T.O. SILL 3'-4"
OVERALL HEIGHT 23'-6"
T.O. UPPER PARAPET
OVERALL HEIGHT 25'-6"
T.O. UPPER PARAPET
DOORS & WINDOWS HEADERS 7'-4"
OVERALL HEIGHT 20'-2"
T.O. UPPER PARAPET
B.O. TYP CANOPY 9'-4"
B.O. MAIN ENTRY
CANOPY 10'-8"
DISCONNECT.
METER
EIFS 2
STUCCO
EIFS-1
REVEALBRICK
BRICK
KNOX-2
FIXED
WINDOW
(TYP.)
5'-0
"
41'-8"41'-8"
EXTERIOR MATERIAL SCHEDULE
LABEL MANUFACTURER SIZE/TYPE FINISH COLOR
STOREFRONT KAWNEER IMPACT RESISTANT ANODIZED ALUMINUM
DOOR - PER DOOR SCHEDULE FACTORY PRIMED
FIXED WINDOW KAWNEER PER WINDOW SCHEDULE ANODIZED ALUMINUM
STUCCO SMOOTH FINISH SW 7504 KEYSTONE GRAY
BRICK VENEER THIN BRICK BY WATSONTOWN MANHATTAN SERIES "WHITE"
EIFS CORNICE & TRIM SMOOTH FINISH SW 7570 EGRET WHITE
EIFS WATER TABLE ROUGH FINISH SW 7504 KEYSTONE GRAY
COVERED ENTRY CANOPY ALUMINUM POWDER COATED ALUMINUM
BAHAMA CANOPY ALUMINUM POWDER COATED ALUMINUM
SERGE FERRARI FABRIC SOLTIS PROOF 502 BLACK
1" PVC REVEAL --- WHITE
PVC STUCCO CONTROL --- WHITE
KNOX BOX 3200 SERIES W/ RECESSED COLOR: DARK BRONZE
(MAIN ENTRY) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)
& TAMPER SWITCH
KNOX BOX 1650 SERIES W/ RECESSED COLOR: DARK BRONZE
(MECHANICAL ROOM) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)
& TAMPER SWITCH
ADDRESS 6" NUMBERS ON 1" STANDOFFS BLACK
FINISH SCHEDULE NOTES:
1. G.C. SHALL VERIFY KNOX BOX MODEL(S) AND LOCATION(S) WITH AUTHORITY HAVING JURISDICTION PRIOR TO
ORDERING/INSTALLATION.
2. G.C. SHALL ENSURE ALL EXTERIOR FINISHES ARE INSTALLED AND FINISHED IN COMPLIANCE WITH
MANUFACTURERS' WARRANTY REQUIREMENTS.
STUCCO
ENTRY
REVEAL
SCJ
KNOX-1
KNOX-2
EIFS 1
EIFS 2
AWNING
BRICK
CANOPY
ADDRESS
CYPRESS RANCH DEVELOPMENT STANDARDS
ARCHITECTURAL STANDARDS (SECTION 4.3): BUILDING MATERIALS
1/A-051 FRONT FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 3,062 S.F.
50% OF TOTAL AREA = 1,531 S.F.
BRICK AREA = 1,904 S.F.
STUCCO/EIFS AREA = 1,158 S.F.
2/A-051 REAR FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 2,670 S.F.
50% OF TOTAL AREA = 1,335 S.F.
BRICK AREA = 1,492 S.F.
STUCCO/EIFS AREA = 1,178 S.F.
3/A-051 SIDE FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 1,396 S.F.
50% OF TOTAL AREA = 698 S.F.
BRICK AREA = 715 S.F.
STUCCO/EIFS AREA = 581 S.F.
4/A-051 SIDE FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 1,307 S.F.
50% OF TOTAL AREA = 654 S.F.
BRICK AREA = 767 S.F.
STUCCO/EIFS AREA = 540 S.F.
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
51
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
EXTERIOR
ELEVATIONS
A-051
SCALE:
1
FRONT ELEVATION
1/8"=1'-0"
SCALE:
2
REAR ELEVATION
1/8"=1'-0"
SCALE:
3
SIDE ELEVATION
1/8"=1'-0"
SCALE:
4
SIDE ELEVATION
1/8"=1'-0"
KT | SV
3335
3
1
2
4
C
A
B
D
LINE OF FINISH
FLOOR- 0'-0"
T.O. SILL 3'-4"
DOORS & WINDOWS
HEADERS 8'-0"
3'-7
"
10'-0"
OVERALL HEIGHT 20'-2"
T.O. LOWER PARAPET
OVERALL HEIGHT 23'-6"
T.O. UPPER PARAPET
EIFS-1
CANOPY
B.O. TYP CANOPY 9'-4"
B.O. MAIN ENTRY
CANOPY 10'-8"
BRICKBRICKEIFS 2 EIFS 2 KNOX-1ADDRESS
STUCCO CANOPY EIFS-1
CANOPY EIFS 2
STUCCOCANOPY
5'-0
"
HOSE BIBB
WEATHERPROOF RECEPTACLE
(TYP; REF. ELEC. DWGS.)
INTERNALLY LIT LED SIGN
35 SF - REF. 3/A-161
FIXED WINDOW
(TYP.)
KEYCODE
LOCKBOX
EIFS 2 EIFS 2 EIFS 2
BRICK
LINE OF FINISH
FLOOR- 0'-0"
B.O. SILL 3'-4"
DOORS & WINDOWS
HEADERS 7'-4"
OVERALL HEIGHT 20'-2"
T.O. UPPER PARAPET
REVEALBRICK
STUCCO EIFS-1SCONCE
DRINKING FOUNTAIN
AWNING AT PLAY AREA (2 TYP.)
REFER TO A-152 FOR ADDITIONAL
INFORMATION AND DETAILS
WEATHERPROOF
RECEPTACLE (2 TYP;
REF. ELEC. DWGS.)
HOSE BIBB
4'-4
"
CALL BOX- REFER TO ELEC. DWG
FOR ADDITIONAL INFORMATION
KEY FOB- REFER TO ELEC. DWG
FOR ADDITIONAL INFORMATION
FIXED
WINDOW
(TYP.)
MTL DOWNSPOUT (TYP.)
COLOR: WHITE
±4
'-4
"
WATER PLAY CONTROL BOX;
COORDINATE WITH VENDOR
FOR EXACT LOCATION
DRINKING FOUNTAIN
WEATHERPROOF
RECEPTACLE (2 TYP;
REF. ELEC. DWGS.)
HOSE BIBB
3'-0"
3'-0"
SCJ
12
'-5
"
OVERALL HEIGHT 20'-2"
B.O. SILL 3'-4"
T.O. UPPER PARAPET
OVERALL HEIGHT 23'-6"
T.O. UPPER PARAPET
OVERALL HEIGHT 25'-6"
T.O. UPPER PARAPET
LINE OF FINISH
FLOOR- 0'-0"
DOORS & WINDOWS
HEADERS 7'-4"
SCONCE EIFS-1
BRICK
STUCCO
STUCCO
B.O. TYP CANOPY 9'-4"
B.O. MAIN ENTRY
CANOPY 10'-8"
EIFS 2REVEAL
35'-0"
LINE OF FINISH FLOOR- 0'-0"
DISCONNECT.
METER
T.O. SILL 3'-4"
OVERALL HEIGHT 23'-6"
T.O. UPPER PARAPET
OVERALL HEIGHT 25'-6"
T.O. UPPER PARAPET
DOORS & WINDOWS HEADERS 7'-4"
OVERALL HEIGHT 20'-2"
T.O. UPPER PARAPET
EIFS 2
STUCCO
EIFS-1
REVEALBRICK
BRICK
KNOX-2
FIXED
WINDOW
(TYP.)
5'-0
"
B.O. TYP CANOPY 9'-4"
B.O. MAIN ENTRY
CANOPY 10'-8"
41'-8"
EXTERIOR MATERIAL SCHEDULE
LABEL MANUFACTURER SIZE/TYPE FINISH COLOR
STOREFRONT KAWNEER IMPACT RESISTANT ANODIZED ALUMINUM
DOOR - PER DOOR SCHEDULE FACTORY PRIMED
FIXED WINDOW KAWNEER PER WINDOW SCHEDULE ANODIZED ALUMINUM
STUCCO SMOOTH FINISH SW 7504 KEYSTONE GRAY
BRICK VENEER THIN BRICK BY WATSONTOWN MANHATTAN SERIES "WHITE"
EIFS CORNICE & TRIM SMOOTH FINISH SW 7570 EGRET WHITE
EIFS WATER TABLE ROUGH FINISH SW 7504 KEYSTONE GRAY
COVERED ENTRY CANOPY ALUMINUM POWDER COATED ALUMINUM
BAHAMA CANOPY ALUMINUM POWDER COATED ALUMINUM
SERGE FERRARI FABRIC SOLTIS PROOF 502 BLACK
1" PVC REVEAL --- WHITE
PVC STUCCO CONTROL --- WHITE
KNOX BOX 3200 SERIES W/ RECESSED COLOR: DARK BRONZE
(MAIN ENTRY) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)
& TAMPER SWITCH
KNOX BOX 1650 SERIES W/ RECESSED COLOR: DARK BRONZE
(MECHANICAL ROOM) MOUNT FLANGE, HINGE DOOR, (REF. NOTE 2 BELOW)
& TAMPER SWITCH
ADDRESS 6" NUMBERS ON 1" STANDOFFS BLACK
FINISH SCHEDULE NOTES:
1. G.C. SHALL VERIFY KNOX BOX MODEL(S) AND LOCATION(S) WITH AUTHORITY HAVING JURISDICTION PRIOR TO
ORDERING/INSTALLATION.
2. G.C. SHALL ENSURE ALL EXTERIOR FINISHES ARE INSTALLED AND FINISHED IN COMPLIANCE WITH
MANUFACTURERS' WARRANTY REQUIREMENTS.
STUCCO
ENTRY
REVEAL
SCJ
KNOX-1
KNOX-2
EIFS 1
EIFS 2
AWNING
BRICK
CANOPY
ADDRESS
CYPRESS RANCH DEVELOPMENT STANDARDS
ARCHITECTURAL STANDARDS (SECTION 4.3): BUILDING MATERIALS
1/A-051 FRONT FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 3,062 S.F.
50% OF TOTAL AREA = 1,531 S.F.
BRICK AREA = 1,904 S.F.
STUCCO/EIFS AREA = 1,158 S.F.
2/A-051 REAR FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 2,670 S.F.
50% OF TOTAL AREA = 1,335 S.F.
BRICK AREA = 1,492 S.F.
STUCCO/EIFS AREA = 1,178 S.F.
3/A-051 SIDE FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 1,396 S.F.
50% OF TOTAL AREA = 698 S.F.
BRICK AREA = 715 S.F.
STUCCO/EIFS AREA = 581 S.F.
4/A-051 SIDE FACADE (EXCLUDING OPENINGS):
TOTAL AREA = 1,307 S.F.
50% OF TOTAL AREA = 654 S.F.
BRICK AREA = 767 S.F.
STUCCO/EIFS AREA = 540 S.F.
P:\1
90
47
_T
LE
L
AN
D O
L
AK
ES
\D
RA
WIN
GS
\9
9_
TL
E_
LA
ND
OL
AK
ES
_A
RC
H\2
01
9.Q
1.0
1 G
EN
P
RO
TO
TY
PE
-A
-0
51
- C
OL
OR
.D
WG
K
EL
SI P
LO
TT
ED
: 1
2/2
7/2
01
9
1. CONTRACTOR SHALL SUPERVISE AND DIRECT
THE WORK USING THE CONTRACTOR'S BEST
SKILL AND ATTENTION. THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE AND HAVE CONTROL
OVER CONSTRUCTION MEANS, METHODS
TECHNIQUES, SEQUENCE, AND JOB SITE SAFETY
2. GC MUST PROVIDE & INSTALL ALL PRODUCTS
PER PLANS. ONLY SUBSTITUTED PRODUCTS
NEED TO BE SUBMITTED TO THE ARCHITECT FOR
APPROVAL. UNAPPROVED SUBSTITUTIONS WILL
BE REPLACED AT THE EXPENSE OF THE GC.
3. VERBAL REPRESENTATION HAS NO VALUE AND
ALL REQUESTS TO CHANGE ANY PRODUCTS OR
SPECIFICATIONS PER PLANS, MUST BE
SUBMITTED IN WRITING TO THE ARCHITECT & TLE
FOR APPROVAL.
2019.Q1.01 GEN PROTOTYPE
NO. DATE DESCRIPTION INT.
REVISION
NO. DATE DESCRIPTION INT.
ISSUE
Drawing Number:
Drawing Name:
Scale:
AS NOTED
Project Number:
19047
Drawn By:
Approved By:
---
AC
AD
EM
Y O
F E
AR
LY
E
DU
CA
TIO
N
PROFESSIONAL CERTIFICATION
NAME OF LICENSEE: STEVEN VINCI
LICENSE NUMBER: AR0017036
EXPIRATION DATE: 2/28/21
FL
-564 &
B
AL
LE
NT
RA
E B
LV
D. A
T
LA
ND
O
' L
AK
ES
PA
SC
O C
OU
NT
Y, F
LO
RID
A
6699
13t
h A
venu
e N
orth
, Sui
te 4
AS
t. P
eter
sbur
g, F
L 33
710
(727
) 38
1-52
20(7
27)
381-
0052
fax
Conceptual Site Plan1 10/28/19
Schematic Design2 12/26/19
EXTERIOR
ELEVATIONS
A-051
SCALE:
1
FRONT ELEVATION
1/8"=1'-0"
SCALE:
2
REAR ELEVATION
1/8"=1'-0"
SCALE:
3
SIDE ELEVATION
1/8"=1'-0"
SCALE:
4
SIDE ELEVATION
1/8"=1'-0"
KT | SV