Download - Contact Point Corrosion - ASNT
![Page 1: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/1.jpg)
Contact Point Corrosioninspection on uninsulated & Insulated piping
Presented by: Brian K. Beresford
Author: Brian K. BeresfordPresident VIR Inspection
Co- Author: Quinn HansonChief Executive Officer
VIRAMID-CPC-CS®Contact Point Corrosion on
Carbon Steel Material
VIRAMID-CPC-SS®Contact Point Corrosion on Stainless
Steel Martial looking for SCC
VIR Inspection LLC320 Dayton Street Suite 260
Edmonds, WA. 98020
Carbon Steel Piping: Inspecting for Corrosion & Pitting. Stainless Steel Piping: inspecting for stress corrosion cracking (SCC)
![Page 2: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/2.jpg)
• A non-destructive technique that utilizes the basic laws of electricity to inundate the conductive material being inspected with AC or DC current
• Results are repeatable and consistent to provide trending inspections and life assessments
• Two Position Test Method
• Current electrodes connect to the voltage source or current source
• Potential electrodes measure a voltage drop along the area of concern of the test specimen in the direction of charge flow (current)
What is Contact Point Corrosion
![Page 3: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/3.jpg)
INDUSTRY WIDE ISSUES
• Process, transfer lines and structural piping hangers and supports create potential corrosion sites. "Touch Point Corrosion“
• Insulated Support, Hangers and Pads require significant amount of time and resources to remove and inspect
• Difficult to find reliable on-line inspection techniques
![Page 4: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/4.jpg)
ADVANTAGES OF USING
• Quick inspection
• User friendly
• Conventional training
• Cost effective
• Repeatable results
• Process does not need to be shutdown in order to perform inspection
• Needs to be bare metal contact so surface must be clear of dust, debris, paint, rust, etc.
![Page 5: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/5.jpg)
APPLICATIONS
•Pads/Clamps•Beam Locations•Saddle Supports•T-connector Supports•Hangers
• Water lines • Water Mains• Flair Stacks• Off Shore• CUI
![Page 6: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/6.jpg)
CALIBRATION CORRECTION FACTORS
• Temperature reading is needed before each set of data• Temperature correction factor Rs=Rm/e(Ts-TM) *In K
where:• RM is the measured resistance• RS is the resistance at the desired temperature• TM is the measured temperature• TS is the desired temperature• K is the coefficient of the given material
![Page 7: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/7.jpg)
INSPECTION VARIABLES
• OD and Nominal Wall of the Test Specimen• Conductivity of the Material• Temperature• Volume(Distance between Electrodes)• Vibration• Test Specimen Condition of Testing Area (Clear of
Debris, Rust, Water, Etc.)• Surface Resistance• Distance of Contacts to measure Potential Drop
![Page 8: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/8.jpg)
T-PIPE AREA
• Inspect T-pipe on different levels of a deck
• Pulled T-Pipe results plus or minus 10%
• Radiography, Digital Radiography and GUL was performed and was unsuccessful
![Page 9: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/9.jpg)
HIGH PRESSURE PIPING “INSPECTION DONE WHILE UNIT IS RUNNING”
![Page 10: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/10.jpg)
HIGH PRESSURE PIPING
Pulled Tube Results
![Page 11: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/11.jpg)
I-BEAMS AND Y-PIPEPipes in Racks
![Page 12: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/12.jpg)
Piping at Supports
Corrosion at I-Beams
![Page 13: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/13.jpg)
Reporting
![Page 14: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/14.jpg)
INSPECTION INTERVALS
• A routine inspection should take place every year or two in order to replicate a trending inspection compared to the original baseline inspection
• This inspection will give us a time frame of degradation decay and thus we will be able to extrapolate to present the predicted life cycle of the test specimen
• CPC testing is recommended after installation of a new test specimen after process is started
• This will accurately determine a baseline inspection in order to provide a precise trending inspection and life expectancy
![Page 15: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/15.jpg)
COST SAVINGS
• Quick inspection• User friendly• Conventional training• Cost effective• Repeatable results• Process does not need to be
shutdown in order to perform inspection
![Page 16: Contact Point Corrosion - ASNT](https://reader031.vdocuments.net/reader031/viewer/2022012518/6192b3f350024729265c5af0/html5/thumbnails/16.jpg)
THANK YOU