NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G This report contains data that are not covered by the NVLAP accreditation.

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 1 of 13

Report Number: PL10604-001A

Model: CPY250-B-xx-F-A-UL-xx-30K

Date: 04/25/2017

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

Report

Prepared For:

Jonathan Vollers

Cree, Inc.

9201 Washington Avenue

Racine, WI 53406

Prepared By: Approved By:

Rob Wieland, Test technician Becky Kuebler, Manager Test Engineering

Page 2: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 2 of 13

Product Information

Manufacturer Cree Inc. Model Number (SKU) CPY250-B-xx-F-A-UL-xx-30K Serial Number PL10604-001 LED Type 36 Cree XPG3 LEDs on LE167x96R0-C LED board

Product Description

White metal housing with integrated heat sink and glass prismatic flat lens

Driver Information (Where Applicable)

Philips 929000708003

Length Width Height

15” 15” 3.5”

Sample

The following sample was submitted for evaluation

Page 3: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 3 of 13

Key Photometric Data Sphere Output Goniophotometer

Luminous Flux 7295 7223.6 lm

Efficacy 119.92 118.67 lm/W

Correlated Color Temperature (CCT) 2977 K

Color Rendering Index (CRI) 72

R9 -29

Duv 0.000879

S/P Ratio* 1.17 Sphere Goniophotometer

Electrical Measurements 120V 277V 120V 277V

Input Wattage 60.83 60.42 60.87 60.36 W

Input Current 0.51 0.23 0.52 0.24 A

Input Voltage 120.02 277.09 120.08 277.02 V

Power Factor 0.995 0.943 0.991 0.905

Off-State Power 0 0 0 0 W

Total Harmonic Distortion (Voltage) 0.04 0.05 0.10 0.09 %

Total Harmonic Distortion (Amperage) 5.59 7.54 19.2 8.58 %

Note: All photometric measurements taken at 120VAC.

Luminous Intensity Distribution Goniophotometer

Max Candela 2789.6 Cd

Angle of Max Candela (Horizontal) 45 ˚

Angle of Max Candela (Vertical) 5 ˚

Key Test Parameters Sphere Output Goniophotometer

Stabilization Time 94 87 min

Total Operating Time (Stabilization + Test) 99 107 min

Ambient Temperature 25.3 24.6 ˚C

Page 4: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 4 of 13

Chromaticity Coordinates

x y u v u’ v’ Duv

0.4398 0.4072 0.2510 0.3487 0.2510 0.5230 0.000879

Color Rendering Index Details

Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

72 68 80 91 70 67 73 79 46 -29 55 65 48 70 95

Chromaticity Diagram

Page 5: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 5 of 13

Spectral Distribution

λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

360 0.000009 530 0.076268 700 0.018055 370 0.000001 540 0.085854 710 0.013340 380 0.000003 550 0.096493 720 0.009876 390 0.000004 560 0.109524 730 0.007253 400 0.000003 570 0.125107 740 0.005242 410 0.001476 580 0.139318 750 0.003850 420 0.010307 590 0.148783 760 0.002782 430 0.034161 600 0.149464 770 0.002016 440 0.071239 610 0.141933 780 0.001472 450 0.067139 620 0.127428 790 0.001057 460 0.026676 630 0.109610 800 0.000717 470 0.012781 640 0.090610 810 0.000489 480 0.009893 650 0.072815 820 0.000295 490 0.013914 660 0.056878 830 0.000169 500 0.027594 670 0.043371 510 0.046628 680 0.032609 520 0.063636 690 0.024369

Dominant Wavelength 582 nm Peak Wavelength 596 nm

Spectral Power Distribution (W/nm)

Page 6: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 6 of 13

Zonal Lumen Summary

Zone Lumens % of Total Zone Lumens % of Total 0-5 66.2 0.90% 90-95 0 0%

5-10 197.1 2.70% 95-100 0 0% 10-15 322.2 4.50% 100-105 0 0% 15-20 440.5 6.10% 105-110 0 0% 20-25 549.3 7.60% 110-115 0 0% 25-30 643.4 8.90% 115-120 0 0% 30-35 713.7 9.90% 120-125 0 0% 35-40 746.4 10.30% 125-130 0 0% 40-45 741.7 10.30% 130-135 0 0% 45-50 705.5 9.80% 135-140 0 0% 50-55 630 8.70% 140-145 0 0% 55-60 516.1 7.10% 145-150 0 0% 60-65 380.8 5.30% 150-155 0 0% 65-70 258 3.60% 155-160 0 0% 70-75 162.1 2.20% 160-165 0 0% 75-80 92.5 1.30% 165-170 0 0% 80-85 45.2 0.60% 170-175 0 0% 85-90 13 0.20% 175-180 0 0%

Total 7223.6 lm 100%

Page 7: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 7 of 13

Candela Plot Illuminance Plot

Roadway Utilization Roadway Summary Lumens % Lamp

Distribution TYPE VS Downward Street Side 3604.2 49.9% Downward House Side 3620.0 50.1% Downward Total 7224.2 100% Upward Street Side 0 0.0% Upward House Side 0 0.0% Upward Total 0 0.0% Total Lumens 7224.2 100.0%

Page 8: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 8 of 13

Luminaire Classification System

Candela Tabulations

Page 9: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 9 of 13

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

0 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761 2761

2.5 2775 2775 2774 2774 2773 2785 2770 2777 2776 2776 2771 2767 2769 2771 2768 2766 2765 2763 2762 2761 2762 2765 2768 2760 2771 2755 2752 2749 2745 2748

5 2778 2782 2778 2777 2780 2790 2772 2775 2774 2772 2767 2761 2763 2764 2762 2760 2760 2760 2761 2761 2766 2774 2786 2782 2789 2766 2760 2755 2747 2754

7.5 2760 2762 2755 2762 2768 2778 2757 2757 2754 2750 2745 2739 2741 2743 2742 2741 2743 2745 2747 2748 2753 2757 2764 2763 2775 2758 2753 2753 2746 2754

10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730 2728 2728 2730 2740 2733 2749 2737 2739 2739 2735 2746

12.5 2705 2715 2710 2716 2718 2724 2703 2708 2707 2707 2706 2705 2711 2717 2716 2716 2714 2712 2710 2708 2708 2711 2728 2723 2735 2722 2720 2714 2716 2729

15 2690 2703 2694 2696 2700 2717 2696 2705 2706 2708 2702 2698 2701 2704 2701 2698 2694 2691 2686 2682 2686 2685 2698 2696 2709 2701 2699 2691 2683 2692

17.5 2675 2692 2672 2676 2683 2691 2677 2688 2688 2687 2681 2675 2678 2680 2678 2676 2669 2663 2660 2657 2669 2671 2671 2667 2687 2667 2663 2665 2657 2670

20 2647 2661 2653 2647 2662 2670 2659 2665 2660 2656 2650 2645 2646 2647 2646 2646 2647 2647 2645 2643 2649 2653 2653 2642 2664 2636 2644 2642 2623 2646

22.5 2630 2640 2634 2626 2633 2640 2628 2638 2632 2626 2624 2621 2621 2620 2615 2609 2605 2602 2604 2607 2622 2621 2615 2609 2628 2602 2613 2611 2604 2627

25 2597 2605 2601 2601 2603 2601 2586 2597 2596 2595 2593 2591 2592 2593 2583 2573 2571 2569 2571 2574 2568 2585 2590 2584 2590 2575 2581 2563 2575 2601

27.5 2544 2558 2560 2556 2570 2565 2562 2556 2554 2553 2546 2540 2540 2541 2540 2539 2541 2543 2537 2531 2517 2535 2543 2540 2547 2531 2534 2526 2523 2544

30 2476 2495 2513 2513 2529 2532 2518 2512 2510 2508 2499 2489 2486 2483 2482 2481 2481 2480 2475 2470 2471 2482 2497 2490 2507 2486 2488 2483 2477 2496

32.5 2370 2391 2414 2438 2469 2480 2460 2452 2446 2439 2431 2424 2420 2417 2412 2406 2400 2394 2395 2396 2395 2403 2430 2429 2456 2433 2437 2417 2421 2446

35 2260 2276 2298 2335 2394 2421 2395 2370 2361 2351 2345 2339 2335 2331 2322 2312 2310 2307 2304 2301 2296 2322 2348 2362 2394 2376 2366 2334 2328 2337

37.5 2132 2155 2169 2219 2284 2341 2308 2283 2268 2254 2237 2220 2212 2204 2196 2189 2181 2172 2169 2166 2173 2205 2253 2280 2329 2316 2270 2218 2212 2219

40 2028 2049 2062 2101 2173 2218 2200 2173 2150 2127 2113 2099 2091 2083 2074 2065 2059 2052 2053 2055 2060 2076 2126 2187 2233 2210 2153 2098 2077 2086

42.5 1914 1927 1948 1980 2038 2084 2066 2047 2027 2007 1995 1982 1979 1977 1971 1964 1957 1950 1948 1946 1950 1960 1995 2057 2118 2081 2029 1975 1959 1951

45 1796 1808 1834 1867 1904 1933 1920 1917 1909 1901 1891 1880 1877 1873 1865 1856 1853 1851 1845 1839 1837 1851 1883 1921 1972 1949 1896 1856 1828 1834

47.5 1654 1668 1702 1739 1764 1773 1785 1789 1789 1789 1781 1773 1761 1750 1741 1731 1730 1729 1721 1714 1721 1737 1775 1793 1805 1806 1767 1728 1697 1713

50 1516 1524 1551 1586 1608 1615 1638 1644 1648 1652 1642 1632 1622 1611 1601 1590 1587 1583 1578 1572 1582 1609 1645 1657 1648 1648 1626 1585 1554 1564

52.5 1366 1381 1406 1431 1437 1454 1473 1486 1489 1491 1486 1482 1475 1469 1460 1452 1446 1440 1436 1433 1438 1467 1494 1500 1486 1482 1471 1440 1410 1412

55 1210 1219 1248 1262 1267 1284 1301 1312 1316 1319 1320 1322 1318 1315 1306 1297 1290 1283 1280 1278 1288 1309 1334 1325 1318 1306 1303 1282 1253 1258

57.5 1067 1070 1089 1094 1095 1109 1125 1133 1137 1141 1143 1145 1141 1138 1132 1126 1120 1113 1110 1108 1114 1136 1162 1146 1140 1123 1127 1114 1093 1095

60 914 914 923 929 926 932 946 951 956 960 962 963 963 963 959 955 950 945 944 942 948 963 976 969 960 946 953 944 932 933

62.5 754 757 763 766 766 766 777 783 785 787 790 793 796 798 792 787 784 781 781 780 783 800 802 796 787 780 782 776 769 765

65 618 621 626 626 622 621 628 634 635 636 640 644 644 644 642 640 637 634 633 633 634 651 651 643 634 631 632 628 623 620

67.5 505 501 509 502 497 496 499 504 506 507 509 511 512 512 512 513 511 508 506 504 507 518 520 510 503 501 503 504 498 503

70 404 400 404 396 392 391 390 393 396 398 398 398 399 400 400 401 400 398 397 395 400 404 405 398 394 394 394 399 393 398

72.5 313 313 313 308 305 302 301 302 304 305 305 306 306 307 306 305 305 304 304 303 306 309 309 306 304 305 307 309 307 308

75 236 239 237 235 232 228 228 227 227 227 228 229 229 228 228 227 226 226 226 225 226 230 230 230 230 231 234 234 234 231

77.5 175 177 177 176 173 170 168 167 167 166 167 167 167 166 166 166 165 165 164 163 164 167 168 168 170 171 174 173 173 171

80 124 126 126 127 124 122 120 118 118 118 118 117 117 117 116 116 116 115 114 114 115 117 119 119 120 122 124 123 122 122

82.5 84 84 85 86 85 84 82 81 80 80 80 79 79 78 78 77 77 76 76 76 77 78 80 81 81 82 83 82 81 81

85 52 51 51 52 52 52 50 50 50 49 49 49 49 48 48 47 47 46 46 46 46 47 49 50 50 50 50 50 49 49

87.5 24 24 24 24 24 23 23 23 22 22 22 23 22 22 22 22 22 21 21 21 21 22 22 22 22 23 22 22 22 22

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Candela Tabulations (Continued)

Page 10: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 10 of 13

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 11: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 11 of 13

Integrating Sphere Equipment List

Description Manufacturer Model Serial Number

2M Sphere Everfine 2M 1004156T

CCD Array Spectrometer Otsuka MC-9801 98010360

Programmable AC Source Adaptive FC200 2280220

Power Analyzer Chroma 66202 66202 0005018

Goniophotometer Equipment List

Description Manufacturer Model Serial Number

AC Power Source Chroma 61602 616020002300

Type C Goniophotometer LSI / UL 6440T 6440PN2028

Spectroradiometer Gooch & Housego 770VIS/NIR 12415189

Power Meter Yokogawa WT210 91M945458

Test Methods Used:

Title Description

ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

CIE Pub. 15:2004 Colorimetry

IES LM-58:1994 Spectroradiometric Measurements

IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

Reference Standard Used:

Equipment Description

2m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119

Type C Goniophotometer and Spectrometer

Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.

Disclaimers:

Page 12: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 12 of 13

This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of the RESTL.

*Items marked with a single asterisk are not covered by the NVLAP accreditation.

In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.

** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as “Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are performed using a Type C goniophotometer.

The integrating sphere information in the equipment list, report items marked with **, or results specifically identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the subcontracted laboratory when subcontracting is indicated on the cover page.

Additional Comments:

The photos below are intended to show the orientation and fixturing/set-up of the units under test. These are critical to understanding the results of the test given the sensitivity of many products and measurement systems to orientation and set-up considerations, and also for reproducing the conditions of the test.

Goniophotometer Integrating Sphere

Page 13: Cree Racine Engineering Services Testing Laboratory (RESTL) … · 2019-05-23 · 10 2721 2730 2730 2743 2753 2759 2735 2739 2739 2739 2736 2734 2737 2740 2737 2734 2733 2732 2730

NVLAP Lab Code 500089-0

Test Report Number: PL10604-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 13 of 13

Document Revision History:

Each subsequent revision of this report replaces the preceding report.

Date Rev DCN # Change Details By Approval

04/25/17 A DMS Origination R. Wieland B. Kuebler