![Page 1: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/1.jpg)
Dark Matter
![Page 2: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/2.jpg)
Dark Matter
Cryogenic Detectors Direct Dark Matter Search
![Page 3: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/3.jpg)
Dark Matter
Matter in the Universe - Composition
‘ν too light‘ =>most of the
Dark Matter is cold
of so far unknown weakly interacting,
massive particlesWIMPs
(50GeV~1000GeVNeutralino?)
⇒
physics beyond standard model
supersymmetry? cold Dark Matter (CDM)0.23
‘normal‘ baryonic matter
0.04
0.001 < ν < 0.02(HDM)
u
d
e
?νe
from ν−oscillations=> Σmν > 0.05eV
Ωmat = 0.27 0.04
![Page 4: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/4.jpg)
Dark Matter
- gravitation Ωmatter
- coupling to radiation Ωbaryon
Cosmic Microwave Background – Matter-Density Ωmatter
Ωmatter = 0.27
Ωbaryon = 0.044 ude
=> Ωmatter Ωlum 0.01
mostly Dark Matter
Anisotropy:
Angular scale => geometry, Ωtot
Intensities => gravitational potentials, matter densities
=> Ωmatter >> Ωbaryon
Wilkinson
Microwave Anisotropy
Probe
Ωtot=1
![Page 5: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/5.jpg)
Dark Matter
Structure in the Universe and Neutrinos
Ωmatter ~ 0.30
< 0.02Ων Σmνi < 1.2eV
Ων < 0.02
![Page 6: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/6.jpg)
Dark Matter
Matter in the Universe - Composition
‘ν too light‘ =>most of the
Dark Matter is cold
of so far unknown weakly interacting,
massive particlesWIMPs
(50GeV~1000GeVNeutralino?)
⇒
physics beyond standard model
supersymmetry? cold Dark Matter (CDM)0.23
‘normal‘ baryonic matter
0.04
0.001 < ν < 0.02(HDM)
u
d
e
?νe
from ν−oscillations=> Σmν > 0.05eV
Ωmat = 0.27 ± 0.04
![Page 7: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/7.jpg)
Dark Matter
- mass 50 GeV - ~ 1000 TeV- relative speed 270 km/s
• nuclear recoils: reduced efficiency of charge or light production
⇒ only a few keV of energy
- cross section- local WIMP-density
⇒ very very rare scattering events (< 1 / week / kg)
χ
WIMP - Direct Detection Weakly Interacting Massive Particles = WIMPs
σχ < 10-36cm2
ρχ 0.3 GeV / cm3
elastic scattering on nuclei
- corresp. 3 WIMPs(100GeV) / liter- 75000 /s /cm2
![Page 8: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/8.jpg)
Dark Matter
WIMP Direct Detection - Signal and Background
Detectorrate,
spectrum
required sensitivity ~ 1 event / kg / week (future experiments even 100 x less)
radioactivity: > 1Hz/kg ~ 106 events /kg /week => ‘clean‘ shielding: (old) Pb, Cumuons ~ 0.1Hz/kg: ~ 105 events /kg /week, => needs ~ 1.5 km Rock
=> Underground-Laboratory
![Page 9: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/9.jpg)
Dark Matter
WIMP Direct Detection - Underground Laboratory
Gran Sasso Lab
shieldingfrom
cosmic rays
Soudan Mine USA
Modane
![Page 10: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/10.jpg)
Dark Matter
WIMP Direct Detection - Experiments
DAMA-LIBRA NaI-Scintillation
ββ Experiments Ge-Ionisation
….
CDMS Ge-Ionisation-Phonons USA Soudan Mine
EDELWEISS Ge-Ionisation-Phonons France, Germany Fréjus-Tunnel
CRESST CaWO4-Scintillation-Phonons Germany, UK, Italy Gran Sasso
…
Conventional Detectors:
Cryogenic Detectors:
Liquid NobleGas Detectors: ZEPLIN Xe-Scint., Scint.-Ionisation UK Boulby Mine
XENON Xe-Scintillation-Ionisation US, Italy, Germany, Portugal Gran Sasso
WARP Ar-Scintillation-Ionisation Italy, US, Poland Gran Sasso
ArDM Ar-Scintillation-Ionisation Switzerland, Spain, UK, Poland CERN, Canfranc?
![Page 11: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/11.jpg)
Dark Matter
Sensitivity WIMP Dark Matter Searches
CRESST 10,5 kg-days CaWO4
30 kgd Ge
SuperK – upward µindirect searches:
conventional:
liquid Xenon:
cryogenic:
![Page 12: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/12.jpg)
Dark Matter
WIMP Direct Detection - Low Temperature – Calorimeter
thermometer types:
superconducting phase transition thermometers (SPT)
NTD - Ge thermistors (highly doped semiconductors)
particle absorption => phonons (~heat)
phonon-absorptionin thermometer=> temperature rise
low temperatures (~20mK)=> high sensitivity, small C
high sensitivity to nuclear recoilsno quenching
low energy threshold
wide choice of absorber materials
thermometer
absorber-crystal
detectedparticle(WIMP)
coupling to heat sink
![Page 13: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/13.jpg)
Dark Mattersuperconducting phase transition thermometerTungsten Tc 15mK
Sapphire- or CaWO4 -absorber250gr, 4cm x 4cm x 4cm
CRESST-Collaboration Cryogenic Rare Event Search with Superconducting Thermometers
Max-Planck-Institut München, TU München Universität Tübingen, Oxford University, Gran Sasso Lab
Superconducting Phase Transition Thermometer
heat capacity– Sapphire 250gr 2 MeV / mK @ 25mK130 GeV / mK @ 1K
![Page 14: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/14.jpg)
Dark Matter
χ
e-
e-
nuclear recoils
phononsonly little ionisation
electromagneticγ, β
ionisation(charge, scintillation light)
![Page 15: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/15.jpg)
Dark Matter
Phonon + Charge / Light Measurement => recognize Background
CRESST II - detectors
thermometer
thermometer
absorber CaWO4
phonon-detector reflecting foil
light detector(low T calorimeter)
χsimultaneous light and phonon measurement
EDELWEISS-France and KarlsruheCDMS - US
simultaneous charge and phonons (semiconductors Ge, Si)
![Page 16: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/16.jpg)
Dark Matter
Ionisation
Thermometer
Ge 300gr oder Si 300gr
Ioniosation-Phonon320g Ge-Detector
EDELWEISS (France) und CDMS (USA) Dark Matter Projects
Testmessung mit Neutronen (=> Kernrückstöße)
‘Low Background Data‘
WIMP Direct Detection – Event by Event Discrimination
![Page 17: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/17.jpg)
Dark Matter
EDELWEISS - Cryogenic Ge-Detectors – Heat / Charge
![Page 18: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/18.jpg)
Dark Matter
EDELWEISS at Frejus tunnel - Results 2003
![Page 19: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/19.jpg)
Dark Matter
EDELWEISS - Results 2003 – 60kg d
EDELWEISS 2002
upgrade – donejust started 7kg run
![Page 20: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/20.jpg)
Dark Matter
Heat / Charge - reduced charge collection from surface
![Page 21: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/21.jpg)
Dark Matter
![Page 22: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/22.jpg)
Dark Matter
EDELWEISS Upgrade – Start 2007
able to run up to 100 detectors
~30kg
started in 2007 with 30 detectors
=> expect new results
![Page 23: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/23.jpg)
Stanford University
University of California, Berkeley
University of California, Santa Barbara
University of Florida
University of Minnesota
Brown University
Case Western Reserve University
University of Colorado at Denver
Fermi National Accelerator Laboratory
Lawrence Berkeley National Laboratory
Santa Clara University
CDMS at Soudan Mine
![Page 24: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/24.jpg)
1 µ tungsten
380µ x 60µ aluminum fins
Q inner
Q outer
A
B
D
C
Rbias
I bias
SQUID array Phonon D
R feedback
Vqbias
CDMS Charge & Phonon Detectors
Qouter
Qinner
zy
x
Measure ionization in low-field (~volts/cm) with segmented contacts to allow rejection of events near outer edge
250 g Ge or 100 g Si crystal 1 cm thick x 7.5 cm diameter Photolithographic patterning Phonon sensors:
• 4 quadrants with each 888 sensors (TES) operated in parallel• TES: 1-µm-thick strip of W connected to 8 superconducting Al collection fins
2 charge electrodes: • “Inner” fiducial electrode• “Outer” guard ring
![Page 25: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/25.jpg)
Dark Matter
CDMS Timing Cut – remove near surface eventsch
arge
/ he
at
~ rise time
![Page 26: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/26.jpg)
CDMS data 2004/2005
Cha
rge
Yiel
d
Prior to timing cuts After timing cuts
Cha
rge
Yiel
d
![Page 27: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/27.jpg)
Dark Matter
CDMS - Results 2005 - 50 kg d
CDMS 2005
continues to runwith ~ 5kg detectors
=> expect more data
![Page 28: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/28.jpg)
Dark Matter
CRESST at Gran Sasso Underground LaboratoryMax-Planck-Institut MünchenTU München Universität TübingenOxford UniversityGran Sasso Lab
![Page 29: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/29.jpg)
Dark Matter
CRESST light - heat - particle identification
γα
n
CaWO4
![Page 30: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/30.jpg)
Dark Matter
CRESST at Gran Sasso Underground Laboratory
![Page 31: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/31.jpg)
Dark Matter
CRESST at Gran Sasso Underground Laboratory
![Page 32: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/32.jpg)
Dark Matter
CRESST at Gran Sasso Underground Laboratory
![Page 33: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/33.jpg)
CRESST 2004 no neutron shield
heat / keV
ligh
t /
hea
t
0 50 100 150-0.5
0.0
0.5
1.0
1.5
Run28, 2004, 10.5 kg d
90% O-recoils
90% W-recoils
CaWO4
crystalsas target
![Page 34: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/34.jpg)
Dark Matter
Sensitivity WIMP Dark Matter Searches
CRESST 2004
now started to run in upgraded and shieldedset up
expect more data
![Page 35: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/35.jpg)
Dark Matter
CRESST upgrade – more channels – neutron shield
66 SQUIDs on He-flange
Shielded cryostat
PE neutron moderator
Plastic scintill. µ-veto
2007: start to install10kg of target mass(33 modules)
2004/05: upgrade to 66 channel SQUID array
2004: installationof PE neutron moderator shield
2005/06: add muon veto(against muon induced neutrons in the Pb/Cu shield)
![Page 36: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/36.jpg)
Dark Matter
CRESST – neutron shield
![Page 37: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/37.jpg)
Dark Matter
CRESST – SQUID system and detectors
![Page 38: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/38.jpg)
CRESST 2007 preliminary (only 3kg d)
Energie im Phononendetektor / keV0 50 100 150
-0.5
0.0
0.5
1.0
1.5
vorläufig, Januar 2007, 3 kg d (Zora)Li
cht-
/Ph
onon
ener
gie
with neutron shield andalpha recoil rejection
![Page 39: Dark Matter - Max-Planck-Institut für Kernphysik · Phonon + Charge / Light Measurement => recognize Background CRESST II - detectors thermometer thermometer absorber CaWO4 phonon-detector](https://reader036.vdocuments.net/reader036/viewer/2022081523/5feb646631004746f0111919/html5/thumbnails/39.jpg)
Dark Matter
Future
EURECA
so far : ~ 1kg targetsin preparation: ~ 10kg targets
=> expect new results soon
long term:
increase sensitivity 1/week/kg toa few/year/100kg
- very very good background control- some 100kg of cryogenic detectors
=> EURECA Collaboration