Transcript
Page 1: Design of Columns to Eurocode

What is columnThe columns in a structure carry the loads from the beams and slabs down to the foundations and therefore they are primarily compression members , although they may also have to resist bending forces and to the continuity structure.

What is columnThe columns in a structure carry the loads from the beams and slabs down to the foundations and therefore they are primarily compression members , although they may also have to resist bending forces and to the continuity structure.

h – larger of the two cross-section dimension

b – Smaller of the two cross-section dimension

Lex - Effective height w.r.t major axis of bending

Ley –Effective height w.r.t minor axis of bending

Lox- Clear height between restrains w.r.t major axis

Loy –Clear height between restrains w.r.t minor axis

Page 2: Design of Columns to Eurocode

Main classification of columns

Page 3: Design of Columns to Eurocode

Effective height of a column

beam

End 1

End 2

non-failing column

failing column

non-failing column

For braced members

π“΅πŸŽ = 𝟎.πŸ“π“΅ΰΆ¨ΰ΅¬πŸ + π’ŒπŸπŸŽ.πŸ’πŸ“+ π’ŒπŸΰ΅°ΰ΅¬πŸ + π’ŒπŸπŸŽ.πŸ’πŸ“+ π’ŒπŸΰ΅°

For unbraced members

π“΅πŸŽ = π“΅ΰΆ§α‰€πŸ + πŸπŸŽπ’ŒπŸΓ— π’ŒπŸπ’ŒπŸ+ π’ŒπŸα‰ and π“΅πŸŽ = π“΅α‰€πŸ + π’ŒπŸπŸ+π’ŒπŸα‰α‰€πŸ + π’ŒπŸπŸ+π’ŒπŸα‰

For braced membersFor braced members

For un-braced membersFor un-braced members

Effective length for isolated membersEffective length for isolated members

Page 4: Design of Columns to Eurocode

Column effective lengths

Effective length factor ,F , for braced columns

Page 5: Design of Columns to Eurocode

300 mm

500 mm

Page 6: Design of Columns to Eurocode
Page 7: Design of Columns to Eurocode
Page 8: Design of Columns to Eurocode

Slenderness ratio of a column

Effective lengths for isolated membersEffective lengths for isolated members

Euercode 2 states that second order effects may be ignored if they are less that 10% of the first order effects. As an alternative, if the slenderness is less than the slenderness limit , then second order effects may be ignored.

Euercode 2 states that second order effects may be ignored if they are less that 10% of the first order effects. As an alternative, if the slenderness is less than the slenderness limit , then second order effects may be ignored.

Page 9: Design of Columns to Eurocode

Limiting slenderness ratio- short or slender columns

βˆ…π‘’π‘“ = effective creep ratio( if not known A can be taken as 0.7)

𝑀= 𝐴𝑠𝑓𝑐𝑑 𝐴𝑐𝑓𝑐𝑑ࡗ� ( if not known B can be taken as 1.1 )

fyd = the design yield strength of the reinforcement

𝑓𝑐𝑑 = design compressive strength of the reinforcement 𝐴𝑠 = the total area of longitudinal reinforcement

Calculating factor β€˜C’ Calculating factor β€˜C’

Page 10: Design of Columns to Eurocode

𝑁𝐸𝑑 = the design ultimate axial load in the column

π‘Ÿπ‘š = 𝑀01 𝑀02ΰ΅—οΏ½ ( if π‘Ÿπ‘š not known then C can be taken as 0.7 )

𝑀01, 𝑀02 are the first order moments at the end of the column

with ȁ!𝑀01ȁ!β‰₯ ȁ!𝑀02ȁ! Design bending momentsDesign bending moments

Page 11: Design of Columns to Eurocode

Short columns resisting moments and axial forces

β€’ The area of longitudinal steel for these columns is determined by,

1. using design charts or constructing M-N interaction diagrams2. a solution of the basic design equations3. an approximate method

β€’ The area of longitudinal steel for these columns is determined by,

1. using design charts or constructing M-N interaction diagrams2. a solution of the basic design equations3. an approximate method

Moment M

Moment M

Load N

Load N

Page 12: Design of Columns to Eurocode

β€’ The basic equations derived for a rectangular section as shown in figure and with a rectangular stress block are,

1. For the depth to the neutral axis x determine the strain Ξ΅sc in the compression steel and the strain Ξ΅st in the tension steel.

2. Determine the steel stresses fsc in compression and fst in tension from the stress-strain diagram .The forces in the steel are Cs= fscAs β€² in compression and T=fstAs in tension.

Page 13: Design of Columns to Eurocode

𝑁𝐸𝑑 βˆ’ design ultimate axial load 𝑀𝐸𝑑 βˆ’ design ultimate moment π‘ βˆ’ the depth of the stress block = 0.8x 𝐴′𝑠 βˆ’ the area of longitudinal reinforcement in the more highly compressed face 𝐴𝑠 = the area of reinforcement in the other face 𝑓𝑠𝑐 βˆ’ the stress in reinforcement 𝐴′𝑠 𝑓𝑠 βˆ’ the stress in reinforcement 𝐴𝑠 ,negative when tesile.

Page 14: Design of Columns to Eurocode
Page 15: Design of Columns to Eurocode

β€’ For most column,biaxial bending will not govern the design.

β€’ Building’s internal and edge columns will not usually cause large moments in both directions.

β€’ Corner columns may have to resist significant bending about both axes,but the axial loads are usually small and a design similar to the adjacent edge columns is generally adequate.

β€’ For members with a rectangular cross section,separate checks in the two principal planes are permissible if the ratio of the corresponding eccentricities satisfies one of the following conditions.

Page 16: Design of Columns to Eurocode

Subject to the following conditions;

a) if π‘€π‘§β„Žβ€² β‰₯ 𝑀𝑦𝑏′

then the increased single axis design moment is

𝑀𝑧′ = 𝑀𝑧 + π›½β„Žβ€²π‘β€² Γ— 𝑀𝑦

b) if π‘€π‘§β„Žβ€² < 𝑀𝑦𝑏′

then the increased single axis design moment is

𝑀𝑦′ = 𝑀𝑦 + π›½β„Žβ€²π‘β€² Γ— 𝑀𝑧

𝛽 = 1βˆ’ π‘πΈπ‘‘π‘β„Žπ‘“π‘π‘˜

Values of coefficient

Page 17: Design of Columns to Eurocode

Design of slender columns

1. A general method based on a non-linear analysis of the structure and allowing for second-order effects that necessitates the use of computer analysis.

2. A second-order analysis based on nominal stiffness values of the beams and column that,again,requires computer analysis using a process of iterative analysis.

3. The β€˜moment magnification’ method where the design moment are obtained by factoring the first-order moment.

4. The β€˜norminal curvature’ method where second-order moments are determined from an estimation of the column curvature.These secon-order moments are added to the first-order moments to give the total column design moment

1. A general method based on a non-linear analysis of the structure and allowing for second-order effects that necessitates the use of computer analysis.

2. A second-order analysis based on nominal stiffness values of the beams and column that,again,requires computer analysis using a process of iterative analysis.

3. The β€˜moment magnification’ method where the design moment are obtained by factoring the first-order moment.

4. The β€˜norminal curvature’ method where second-order moments are determined from an estimation of the column curvature.These secon-order moments are added to the first-order moments to give the total column design moment

Page 18: Design of Columns to Eurocode
Page 19: Design of Columns to Eurocode