DOMEKT

Domekt R 400 F (DomektREGO400P)

460

25

62

1~ 230

HE 7,3 / HW 3,3

83

0,09

50

0,45

278×258×46-M5

58

164

1,0 / 6

KOMFOVENT C4 / C4.1

62

71

62

71

44

32

1,4 1,4 1,4 1,4

60 60 59 59

1 1 1 1

12,5/22

4,0 3,3 2,5 1,8

½

315×315×220

DH-200

C4

C4.1

A

460 m³/h44

0 0,02 0,04 0,06 0,08 0,1 0,12 0,14

0 100 200 300 400 500 600

300

250

200

150

100

50

0

SFP 1,25

SFP 0,75

SFP 0,5

SFP 1

100 200 300 400 500 600

92

88

84

80

76

72

12,5 14,2 15,3 16,3 17,4 23,7

B D

AC

BD

A C

E

D

A C

BD

C A

B

20 125425

20100

155 1551120

310 3101160

200

310

310

200

650

200 (4×)

KK2-16-03UAB AMALVA reserves the right to introduce the changes of parameters and sizes in the process of improvement of the air handling units.

All data can be calculated in DOMEKT selection software. If data of performance do not correspond to data in the selection software, please refer to data shown in software.

The

phot

o is

inte

nded

for i

nfor

mat

iona

l pur

pose

s on

ly, e

xact

det

ails

may

var

y.

Stat

ic p

ress

ure

(Pa)

Performance Air flow rate (m3/s)

Air flow rate (m3/h)

Air flow rate (m3/h)

Tem

p. e

ffici

ency

(%)

Temperature efficiency

Indoor and outdoor ∆T=13°C re: Ecodesign 1254/2014.

Acoustic DataA-weighted sound power level LwA, dB(A)at reference flow rate

Supply Inlet

Supply Outlet

Exhaust Inlet

Exhaust Outlet

Casing

A-weighted sound pressure level LPA, dB(A) 10 m² normally isolated room, distance from casing – 3 m.

Surroundings

Nominal air flow, m³/h

Panel thickness, mm

Unit weight, kg

Supply voltage, V

Maximal operating current, A

Thermal efficiency of heat recovery, %

Reference flow rate, m³/s

Reference pressure difference, Pa

SPI, W/(m³/h)

Filters dimensions B×H×L, mm

Electric power input of the fan drive at reference flow rate, W

Electric power input of the fan drive at maximum flow rate, W

Electric air heater capacity, kW / ∆t, °C

Control panel

Hot water duct air heater (DH)**Winter

Water temperature in/out, °C 90/70 80/60 70/50 60/40

Capacity, kW

Flow rate, dm³/h

Pressure drop, kPa

Temperature in/out, °C

Maximal capacity, kW

Connection, ”

Dimensions, mm

Hot water duct heater type

** option

Temperature efficiencyWinter Summer

Outside temperature, °C -23 -15 -10 -5 0 30

After heat exchanger*, °C

* indoor +22°C, 20 % RH

A outdoor intakeB supply airC extract indoorD exhaust airE additional extraction connection (by-pass –

extraction without heat recovery)

Shown as right (R1)

Shown as left (L1)