Download - DrugWipe Saliva Test
Remove the blue sample collector from the white test cassette.
Replace sample collector onto test cassette. The sample collector must lock in place with an audible double click.
Applying slight pressure, wipe surface (e.g. forehead, steering wheel)
Remove protection cap and fill to mark with water.
Dip detection zone gently into filled protection cap for 15 seconds, then remove. CAUTION: Do not immerse the white plastic body!
DrugWipe® Test for Sweat and Surfaces
Place test on a horizontal surface for 10 minutes. Then evaluate test. Ignore results that show be-fore the 10 minutes are complete, or after more than 10 minutes.
Wet sampling pads on collector Shake off any excess water. Do not touch sampling pad.
1
3
4
5
6
7
Sampling Sweat (forehead and neck at the hair line)
Advise the test person to move his tongue around the bottom of the cheek 3 times. With the sample collector saliva is wiped from the tongue or interior cheeck.
Remove the blue sample collector from the white test cassette.
Place the blue sample collector back onto the white test cassette. Both sampling pads must connect with an audible double click.
Hold the test cassette vertically, ampoule at the bottom. Squeeze your thumb thoroughly on the word PRESS in order to break the ampoule. Hold the test cassette with the broken ampule vertically for 10 to 15 seconds.
DrugWipe® Saliva Test
PRESS
Click!Click!
13
4
5 Move the cap back into starting position. Lay the test on a horizontal surface and commence timing. Read the test result after 8 minutes. Ignore test results before and after. Do not move the test during that time.
2
Check sampling pads for colour change from red to yellow. This indicates sufficient saliva collection.Sample collector
Sampling pads
Test cassette
Read-out window
Ampoule
Sampling in Saliva (tongue, oral cavity – shake off any excess saliva)
2
Sampling pads
Sample Collector
Portection cap
Read-out window
Test cassette
15 seconds
3–8 minutes
no consumption of drugs (only red control lines
are visible)
cause: wrong handling or malfunction of test repeat
with new test
Tests successful
Cannabis
XTC/ Amphetamines
Cannabis, Cocaine, XTC/Amphetamines, Heroine/Opiates
Test failed
Cocaine
Heroine/Opiates
Test successful: positive on drug consumption
For detailed information please ask for manual.
Read out at 10 minutes (5 parameters test)
Test result Detection window for Cannabis ( THC) Reaction of pupils after consumption
Sampling Saliva (Mouth)
Sampling Sweat (forehead)
Sampling Urine
If onsite testing is positive: take a bloodtest ASAP!
If onsite testing is positive: take a bloodtest ASAP!
4-6 hrs.
Concentration
6-10 hrs.
Blood
Saliva
4-6 hrs.
Concentration
10-12 hrs.
Blood
Sweat
1 2
4-6 hrs.
Concentration
5-8 Days
Blood
Urine
Test results:
Saliva Blood
Saliva Blood
Saliva Blood
Lower detection limit Salivatimeframe
Test results:
Sweat Blood
Sweat Blood
Sweat Blood
Lower detection limit Sweattimeframe
Test results:
Urine Blood
Urine Blood
Urine Blood
Lower detection limit Sweat Urinetimeframe
Securetec Detektions-Systeme AGEugen-Sänger-Ring 1 • 85649 Brunnthal • GermanyT +49 89 203080-1651 • F +49 89 [email protected] • www.securetec.net© 2012 Securetec Detektions-Systeme AG • 70512-v02-EN-120425
Drug
Cannabis
Heroine/Opiates
Cocaine
XTC/Amphetamines
Size of pupils Reaction to light
normal to dilated normal to decelerated (reddened, glossy eyes)
narrowed hardly noticeable
dilated decelerated
dilated decelerated
5,5 mm 5,0 mm
4,5 mm
4,0 mm
3,5 mm
3,0 mm
2,5 mm
2,0 mm
1,5 mm
1,0 mm
6,0 mm
6,5 mm
7,0 mm
7,5 mm
8,0 mm
8,5 mm
9,0 mm
Her
oine
/Opi
ates
Ligh
t re
flex
is n
on e
xist
ent
Can
nabi
s
Coc
aine
/XTC
/Am
phet
amin
es
1 2
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL
CO
OP
CA AM/MET
CL CL CL