4
Ducted Air ConditioningThe ultimate in air conditioning
Ducted air conditioning is surely the ultimate in comfort. The Fujitsu ducted models offer quiet,
efficient operation, are easy to maintain, and operated via a wall mounted LCD control that controls
all functions of the system.
Invisible comfort
Whatever shape of the room, ducted units create
uniform temperatures throughout. The unit is
totally concealed, usually within a ceiling void.
Cool or warm air is then ducted into each room
through outlets positioned in the walls, floor or
ceiling. Easily controlled, Fujitsu’s ducted systems
provide comfort throughout your house without
leaving cool or hot spots.
The ducted air conditioning system
• Perfect comfort throughout each room
• Visually appealing
• Concealed installation
• Reverse cycle heating and cooling
• Quiet operation
• Easy-to-use LCD controller
Tem
p.
Set Temp.
Time
Temp.
Power
Tem
p.
Set Temp.
Time
Temp.
Power
On
OnOn
OffOff
CONVENTIONAL MODEL
RoomTemp.
Time
Set Temp.
Conventional
Inverter
T/2T
Room Warming Speed
DC twinrotarycompressor
Compressor COP100
90
80(%)
2 4 6 8
Cooling Capacity(kW)
COP
10 12
Comparison of cooling efficiency of DC compressor(against AC compressor)
AC Twin RotalyDC Twin Rotary
Power and Speed
INVERTER MODEL
The highly efficient DC Inverter twin rotary compressor can reach the room temperature you set up to
15% quicker than conventional models and precisely maintain temperature. The DC Inverter twin rotary
compressor makes operation at high power & high efficiency a reality. *(AOT30/36 models only)
The Inverter component allows
the outdoor unit to vary its speed
and output to match the required
capacity of the indoor unit.
Thus, the Inverter model can achieve
30% more operating efficiency than
conventional models and therefore,
is much cheaper to run.
5
Inverter Ducted TechnologyAs a world leader in energy efficient air conditioning systems, Fujitsu is committed to delivering highly
engineered inverter ducted systems. The new inverter ducted units feature an advanced scroll compressor
(AOT45/54L models only) to deliver optimum power without compromising on efficiency. Equipped with
sophisticated inverter technology, the Fujitsu inverter ducted systems are more economical to operate
and quieter to run than conventional units. The inverter component allows the outdoor unit to vary
its speed and output to match the required capacity of the indoor unit, making it up to 30% cheaper
to run than a conventional ducted system.
Fujitsu's inverter ducted air conditioning systems have been designed for easy installation in the
ceiling and roof space.
What's an inverter?
Through new, advanced technology, Inverter air conditioners are
more economical to operate and quieter to run than conventional
units. They can handle greater extremes in temperature, are
smoother and more stable in operation and reach the desired
temperature more quickly than conventional air conditioners.
Comparison of colloing efficiency of DC compressor(against AC compressor)
DC Inverter
Constant-Speed
50%Off
Approx.
Energy savings over one year
DC Inverter
Constant-Speed
Highly efficient R410A refrigerant
The R410A refrigerant, which is used in Fujitsu's Inverter ducted
systems, has zero ozone depletion potential as it contains no
chlorine. R410A also provides excellent stability and low toxity,
as well as offering superior energy saving.
Inverter control
DC twin rotary compressor*
Wired remote controller with cover
Compact high static ducted features(LUAK/UUAK)
Temperature set back timer
Group control
One remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same settings.
Dual remote controllers (optional)
An additional controller can be added up to the maximum of two remote
controllers. Either remote controller can control the air conditioner.
However, the timer functions cannot be used at the slave unit.
Connectable quantity: Maximum 16 indoor units for 1 remote controller
Wired remote controller Example of ducted system configuration
Indoor Outdoor
Fresh air
Heater
Indoor
SET BACK temperatureON 28°c
24°c 24°c
OFF
NORMAL temperature
40cm
125cm80cm
40cm
105cm50cm
CURRENT MODEL: 75kg NEW MODEL: 50kg
Cobalt blue heat exchanger
The outdoor unit fins are coated with a blue corrosion
resistant material to enhance durability and extend
performance life of your air conditioner.
Use this timer function to change the set temperature
in the operation times set for each day of the week.
This can be used together with other timer settings.
Commercial mode
By enabling the indoor
unit’s internal controls,
you can achieve a
continual fan operation
in the heating mode, as
required for commercial
installations.
Child lock function
Simply pressing a combination of buttons
on the standard wired remote controller,
locks and unlocks the keypad, stopping
accidental and unauthorised use.
Simplified wired remote controller (optional)
This controller can be used as an optional slave
controller for dual comfort. It offers easier operation
and backlit display.
1. Fresh air output port. External fresh air fans can be
connected to run in conjunction with the fan motor of
the indoor unit.
2. Electrical heater output port. An External Electrical
heater can be set to operate in conjunction with the
heating cycle.
3. External input port. Start/stop of the air conditioner
can be controlled from external equipment.
Advanced features (UTD-ECS5A Required)
Hydrophillic coatingCobalt Blue protectionStandard cromate protectionAluminium base material
Detecting point can be changed easily
DAY NIGHT
Remote Sensor Opt
Wired Remote Controller
6
Room temperature sensor selection
• Remote controller has remote
sensor included.
• User can select between remote
controller sensor and/or
return air sensor or
remote sensor.
Remote Sensor in the bedroom
(effective at night)
Remote Controller in the living room
(effective during the day)
Example of ducted system configuration
Easy installation (compact size & light weight).
Size & weight have been reduced making installation considerably easier.
Operation sound (low noise)
The new ducted models have increased airflow volume
& decreased noise levels to 49dBA by adopting a
plastic case, plastic fan and three airflow volume
switch positions.
7
INVERTER Ducted
ART30L
8.80kW / 30,000BTU/h
9.20kW / 31,400BTU/h
C
H
ART36L
10.00kW / 34,100BTU/h
10.00kW / 34,100BTU/h
C
H
ART45L
12.50kW / 42,700BTU/h
14.00kW / 47,800BTU/h
C
H
ART54L
14.50kW / 49,500BTU/h
16.00kW / 54,600BTU/h
C
H
ARY36L*
10.00kW / 34,100BTU/h
11.20kW / 38,250BTU/h
C
H
Wired type (with weekly/setback timer) For ARY36L
Wired type (with weekly/setback timer)
For ART45L/54L
For ART30L/36L
* Project order only. Minimum Delivery time 16 weeks
Control Features
Turbulent air flow is reduced by cutting off the corners of the conventional
indoor unit front panel and fan case. Uniform internal air pressure
decreases the noise level down to 41dBA (ART45L) and 42dBA (ART54L).
• Large air flow volume of 972 Litres/second (ART45/54L) is achieved
by adopting a larger fan. (Figures given at 100Pa).
• Low noise is achieved by use of a plastic case, plastic fan and
3-step airflow volume switch.
• Sirocco fan for airflow and indoor unit fan casing are also made
from plastic.
Operation sound (Low noise)
Current model NEW MODEL
Current model : Metal fan [53.1dB(A)]
* Model : Material (At 100Pa : Actual noise measurement value)
NEW MODEL : Plastic fan [41dB(A)]
800mm
Metal fan (ø240mm)
Casing (Metal Sheet)
40
0m
m
Heat exchangerPlastic fan
Casing (Plastic)
500mm
40
0m
m
ø225mmHeat exchanger
1 2 3
Various remote controllers and sensors can be
selected.
1. Wired Remote Controller with Thermo Sensor
• Room temperature sensor selection
• WEEKLY timer
• Temperature SET BACK timer
• Group control system
• Child lock
• Dual remote controllers (optional parts)
• AUTO restart
• Energy saving
• Auto changeover (for heating)
• Hot start (for heating)
2. Simple Remote Controller (optional parts)
3. Remote Sensor (optional parts)
- (01 - 05) -
DU
CT
TYPE
AR
TC36
-60L
DU
CT
TYPE
AR
TC36
-60LSPECIFICATIONS3.
TypeDUCTED MODEL
INVERTER HEATPUMPModel name ARTC36LCTU ARTC45LCTU ARTC60LCTUPower source 240V~ 50HzAvailable voltage range 198-264V~ 50Hz
Energy label (Number of star mark)Cooling - - -Heating - - -
Capacity
CoolingRated
kW 10.0 12.5 15.0BTU/h 34100 42700 51200
Min-MaxkW 4.7-11.4 5.4 - 14.0 6.0 - 17.5
BTU/h 16000 - 38900 18400 - 47800 20500 - 60000
HeatingRated
kW 11.2 14.0 18.0 BTU/h 38200 47800 61500
Min-MaxkW 5.0-14.0 5.8 - 16.2 6.4 - 20.0
BTU/h 17100 - 47800 19800 - 55300 21800 - 68300
Input powerCooling
Rated
kW
3.09 4.06 5.32Max 5.63 6.37 7.40
HeatingRated 2.94 3.67 5.28Max 5.63 6.37 7.40
CurrentCooling
Rated
A
4.4 5.8 7.5 Max 9.0 11.0 12.5
HeatingRated 4.2 5.2 7.5 Max 9.0 11.0 12.5
EER CoolingkW/kW
3.24 3.08 2.82 COP Heating 3.81 3.81 3.41 Moisture removal l/h (pints/h) 1.5 (3.2) 1.5 (3.2) 3.0 (6.3)
Fan
Air� owrate
Cooling
High
m3/h
2500 3450 3450Med 1950 2980 2980Low 1450 2560 2560Quiet - - -
Heating
High 2500 3350 3350Med 1950 2850 2850Low 1450 2430 2430Quiet - - -
Type × Q'ty Sirocco × 2Motor output W 240 490
Recommended static pressure Pa 100 to 200 100 to 250 100 to 250
Sound pressure level
Cooling
High
dB(A)
43 47 47Med 38 43 43Low 33 40 40Quiet - - -
Heating
High 43 47 47Med 38 43 43Low 33 40 40Quiet - - -
Heat exchanger type
Dimensions (H × W × D)mm
336 × 890 × 53.2Fin pich 1.30 Rows x Stages 4 × 16Pipe type CopperFin type Aluminium
Enclosure Material SteelColour -
Dimensions( H×W ×D )
Netmm
400 × 1050 × 500Gross 460 × 1230 × 640
WeightNet
kg(lb.)42 (92) 46 ( 101 )
Gross 47 (103) 51 ( 112 )
Connection pipeSize
Liquidmm
Ø 9.52 (Ø 3 / 8 in.)Gas Ø15.88 (Ø 5 / 8 in.)
Method Flare
Operation rangeCooling
°C 18 to 32%RH 80 or less
Heating °C 16 to 30Remote controller type Wired
Drain pipeMaterial SteelSize mm Outer diameter: 25.4 / Inner diameter: 23.4
Note : Speci� cations are based on the following conditions.Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24 °CWB.Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB.Standard static pressure : 100 Pa.Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)Sound pressure level : Install a 2m duct to the outlet port and a 1m duct to the suction poit and measure.The maximum current is the maximum value when operated within the operation range(temperature
16
Type INVERTER
Model No.Indoor Unit ART30LUAK ART36LUAK ART45LUAK ART54LUAK ARY36LUANOutdoor Unit AOT30LMBDL AOT36LMADL AOT45LJBYL AOT54LJBYL AOY36LMBWL
Reverse Cycle System Yes Yes Yes Yes YesOptional Simple Wired RC UTB-TPB UTB-TPB UTB-TPB UTB-TPB UTB-TPBOptional Remote Sensor UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100 UTD-RS100
Cooling CapacityWatts 8800 10000 12500 14500 10000BTU/h 30000 34100 42700 49500 34100
RangeWatts 2700-9800 2700-10500 3600-14000 6400-15300 Max 11200BTU/h 9200-33500 9200-36000 12300-47800 21900-52200 Max 38200
Heating CapacityWatts 9200 10000 14000 16000 11200
BTU/h 31400 34100 47800 54600 38250
RangeWatts 3000-11000 3000-12100 4700-18000 6800-20000 Max 12770BTU/h 10200-37600 10200-41300 47800-61500 23200-68300 Max 43600
Power Supply Volts 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor Outdoor
Running Current Cooling Amps 13.8 (4.6-17.3) 16.7(4.6-17.6) 18.1(7.1-21.7) 23.5 (7.1-25.3) 17.9 (Max 18.4)Heating Amps 10.7 (4.3-17.3) 11.7 (4.3-17.6) 16.0 (6.3-20.1) 19.8 (6.3-25.3) 13.9 (Max 18.4)
InputCooling Watts 3300 (1080-4150) 4000 (1080-4200) 4300 (1700-5200) 5570 (1700-6060) 4080 (Max 4200)Heating Watts 2550 (1000-4150) 2800 (1000-4200) 3800 (1500-4800) 4700 (1500-6060) 3180 (Max 4150)
Moisture Removal l/hr 3 3 3 4 3E.E.R. Cooling 2.67 2.5 2.91 2.6 2.45C.O.P. Heating 3.61 3.57 3.68 3.40 3.52
Star RatingCooling ★★★ ★★★■ ★★★★ ★★★ -Heating ★★★★★ ★★★★★ ★★★★★★■ ★★★★★■ -
Fan Speeds 3 3 3 3 3Ex Static Pressure Range Pa 100 to 200 100 to 200 100 to 250 100 to 250 30 to 150Air Circulation High l/s 694@100Pa 694@100Pa 972@100Pa 972@100Pa 486Compressor Type DC Twin Rotary DC Twin Rotary DC Scroll DC Scroll DC Twin Rotary
Height mm 400 400 400 400 270I.U. Width mm 1050 1050 1050 1050 1135
Depth mm 500 500 500 500 700Dimensions Net Weight kg 45 45 50 50 43and Weights Height mm 900 900 1290 1290 830
O.U. Width mm 900 900 900 900 900Depth mm 350 350 330 330 330Net Weight kg 70 70 105 105 64
Duct Work Plenum SizeSupply mm 850 x 295 850 x 295 850 x 295 850 x 295 1065 x 202Return mm 865 x 325 865 x 325 865 x 325 865 x 325 1015 x 240
Optional Supply SpigotsSquare Qty 1 - - - - UTD-SFO45TRound Qty 4 - - - - UTD-RF204
I.U. Sound Pressure Level dBA@1mtr 45 45 49 49 43O.U. Sound Pressure Level dBA@1mtr 53 53 54 54 54O.U. Sound Power Level dBA 65 65 65 69 66Refrigerant Type R410A R410A R410A R410A R410A
Connection Pipe SizesGas mm 15.88 15.88 15.88 15.88 15.88Liquid mm 9.52 9.52 9.52 9.52 9.52
Refrigerant Pre Charged Length Metre 10 10 20 20 15Minimum Pipe Length Metre 5 5 5 5 5Maximum Pipe Length Metre 30 30 70 70 50Maximum Pipe Height Metre 20 20 30 30 30Pipe Connection Methods Flare Flare Flare Flare Flare
Outdoor Operating Temp.Cooling Degrees C 0 to 43 0 to 43 -15 to 43 -15 to 43 -10 to 43Heating Degrees C -10 to 21 -10 to 21 -15 to 24 -15 to 24 -10 to 24
DUCTEDINVERTER
Type WALL MOUNTED FLOOR/CEILING
Model No.Indoor Unit AST7LMACW AST9LMACW AST12LMACW AST18LBAJ AST24LBAJ ABT14LBAJ ABT18LBAJ ABT24LBAJOutdoor Unit - - - - - - - -
Reverse Cycle System Yes Yes Yes Yes Yes Yes Yes Yes
Cooling CapacityWatts 2300 2700 3500 5200 6800 4200 5200 6800
BTU/h 7900 9200 11900 17800 23200 14300 17800 23200
Maximum Watts 2700 3400 3700 6000 7400 5000 6000 7400
BTU/h 9200 11600 12600 20500 25300 17200 20500 25300
Heating CapacityWatts 2700 3300 3800 6000 8200 4800 6000 8200
BTU/h 9200 11300 13000 20500 28000 16400 20500 28000
Maximum Watts 3300 3700 4500 7100 9000 5700 7100 9000
BTU/h 11300 12600 15400 24200 30700 19500 24200 30700Power Supply Volts 240 240 240 240 240 240 240 240Phase-Frequency Ph- Hz 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50Power Supply Attachment Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor OutdoorPlug Size (If Applicable) - - - - - - - -
Cooling Amps - - - - - - - -
Running Current Range Amps - - - - - - - -Heating Amps - - - - - - - -Range Amps - - - - - - - -Cooling Watts - - - - - - - -
InputRange Watts - - - - - - - -Heating Watts - - - - - - - -Range Watts - - - - - - - -
Moisture Removal l/hr 1 1.2 1.6 3 3 1.5 1.7 2.5E.E.R. Cooling - - - - - - - -C.O.P. Heating - - - - - - - -
Star RatingCooling - - - - - - - -Heating - - - - - - - -
Fan Speeds 4 4 4 4 4 3 3 3Air Circulation High l/s 119 130 144 263 283 177 216 244Compressor Type - - - - - - - -
Height mm 257 257 257 320 320 199 199 199
I.U.Width mm 808 808 808 1120 1120 990 990 990Depth mm 187 187 187 220 220 655 655 655
Dimensions Net Weight kg 8 8 8 16 16 28 28 28and Weights Height mm - - - - - - - -
O.U. Width mm - - - - - - - -Depth mm - - - - - - - -Net Weight kg - - - - - - - -
I.U. Sound Pressure Level dBA@1mtr 34 36 38 43 47 36 43 48O.U. Sound Pressure Level dBA@1mtr - - - - - - - -O.U. Sound Power Level dBA - - - - - - - -Refrigerant Type R410A R410A R410A R410A R410A R410A R410A R410A
Connection Pipe SizesGas mm 9.52 9.52 9.52 12.7 15.88 12.7 12.7 15.88Liquid mm 6.35 6.35 6.35 6.35 9.52 6.35 6.35 9.52
Pre Charged Length Metre - - - - - - - -Minimum Pipe Length (per unit) Metre - - - - - - - -Maximum Pipe Length (per unit) Metre - - - - - - - -Maximum Pipe Length Metre 25 25 25 25 25 25 25 25Maximum Pipe Height Metre 10 10 10 10 10 10 10 10Pipe Connection Methods Flare Flare Flare Flare Flare Flare Flare Flare
Outdoor Operating Temp.Cooling Degrees C - - - - - - - -Heating Degrees C - - - - - - - -
MULTI SYSTEM INVERTERINVERTER
4
Inverter technology
What's an inverter?
Through new, advanced technology, Inverter air conditioners are more
economical to operate and quieter to run than conventional units.
They can handle greater extremes in temperature, are smoother and
more stable in operation and reach the desired temperature more
quickly than conventional air conditioners.
DC twin rotary compressor
The Fujitsu Inverter System is equipped with a state of
the art DC twin rotary compressor. It can reach the room
temperature you set 15%* quicker than conventional
models and precisely maintain it at a difference of just
0.5°C. Advanced DC twin rotary compressor makes
operation at high power and high efficiency a reality.
RoomTemp.
Time
Set Temp.
Conventional
Inverter
T/2T
Maximum Power
Conventional Inverter
Room Warming Speed
Inverter control
The Inverter component allows the outdoor unit to vary its
speed and output to match the required capacity of the indoor
unit. Thus, the Inverter model can achieve 30% more operating
efficiency than conventional models and therefore, is much
cheaper to run.
Power and Speed
INVERTER MODEL CONVENTIONAL MODEL
Compressor COP100
90
80(%)
2 4 6 8
Cooling Capacity(kW)
COP
10 12
Comparison of cooling efficiency of DC compressor(against AC compressor)
AC Twin RotalyDC Twin Rotary
DC twin rotary compressor
High Energy Efficiency
The high efficiency DC Inverter Multi System offers energy
saving operation and 50% higher efficiency than a constant-
speed multi system. Improved Inverter cooling ratio prevents
a drop in capacity when operating under load conditions.
Stable & Comfort
The air conditioner's output is stabilised at the optimum setting
within the range from maximum to minimum to match the load, which
is affected by factors such as the room temperature and the number
of people present.
DC Inverter Multi System
Constant-Speed Multi System
50%Off
Approx.
Energy savings over 1 year
*Depends on room size and heat load.(Selected models only)
Tem
p.
Set Temp.
Time
Temp.
Power Tem
p.
Set Temp.
Time
Temp.
Power
On
OnOn
OffOff
FG0050_RETAIL08.qxd 27/8/08 1:10 PM Page 4
5
I-PAM
Conventional PAM
Control range between energy saving and high power is
small because vertical interval of voltage and motor
revolution is narrow.
V-PAM
V-PAM achieves high power by increasing the voltage up to
380V and making the motor rotate faster and also saves
energy in the stable state by making the motor rotate slower
than that of conventional models by lowering the voltage.
V-PAM
V-PAM technology makes the
compressor more powerful.
More compact than
conventional models.
380V
Voltage control of V-PAM
Voltage control of conventional PAM
Motor revolution
Vertical interval of motor revolutionis wide
Vertical intervalof voltage is wide
Vertical intervalof voltage
Vertical interval of motor revolution is narrow
High
Low SaveenergyPower
240V
Voltage
Output increased to greater than that of conventional model
PowerHigh
Low
New model
Conventional model
Saving electricity cost.
Electricity chargeHigh
LowNew model
Conventional model
Comparison between V-PAM &conventional PAM.
V-PAM
V-PAM inverter increases the maximum output of the compressor
significantly and enables high power and high efficiency.
G
H
G
H
Energy saving and speedy heating only possible by I-PAM
I-PAM
1. Heats in approximately 1/3 of the time of our previous inverter models
2. Rises rapidly
3. Pleasant temperature in 10 minutes
4. High power operation
5. Energy saving operation
PREVIOUS INVERTER
6. Incomplete energy saving
7. Still cold
8. Temperature rise is slow
9. Pleasant temperature in approximately30 minutesCompressor motor voltage and speed Heating 10cm from the floor
Through advances in our inverter
technology, Fujitsu has now introduced
I-PAM (Intelligent Power Module-Pulse
Amplitude Modulation) technology.
I-PAM is able to extract superior
performance capabilities by adding
an IPM board to conventional inverter
PAM control.
3.01
3.61
PAM board
IPM board
30
20
10
Temp.(0C)
Start10 20 30 40
Time
Our conventional type inverter model
30
20
10
10 20 30 40
Temp.(0C)
TimeStart
I-PAM control model
6 9
67
852
1 3
4
COP
(Coefficient of
Performance)
I-PAM control model Our previous inverter model
I-PAM control panel
This year
5 years ago
FG0050_RETAIL08.qxd 27/8/08 1:10 PM Page 5
Energy saving by automatic filter cleaning function.
This function allows an energy saving of more than 25% a year
and maintains a smooth air flow by preventing the filters from
being clogged with dust.
Computer-designed fan provides a larger air flow than conventional models.
New air trunk, which provides a smooth air flow & gap fan motor
increase the maximum air flow by10% over that of conventional
models. CAE: Computer Aided Engineering
Axial gap fan motor enables non-conventional high power and high efficiency.
Axial gap method
Rotor plates are installed above & below electromagnets.
Features (Compared to conventional models)
• Compact size with 1.5 times more power output.
• Self-driven method increases rotating efficiency by10%.
• Our electromagnetic field simulation technology
enables low vibration and low noise.
AWTZ14LB
Hi-EER: 4.12 (W/W)
Hi-COP: 4.44 (W/W)
4.20kW/14,300BTU/h
6.00kW/20,500BTU/h
Automatic filter cleaning air conditioner.
The revolutionary NOCRIA ceiling wall models have vastly
improved heating and cooling efficiency and energy saving.
These elegant units are designed to sit very high on the
wall, just 40mm below the ceiling and remain very
unobtrusive. The automatic self cleaning filter system
ensures highly efficient operation and the UV filter
disinfects and deodorises the air.
Available only from selected outlets.
CONVENTIONAL MOTOR
Rotor is bounded by electromagnet.
CAE Analysis
NEW MODEL
INVERTER
C
H
AWTZ18LB
Hi-EER: 3.289 (W/W)
Hi-COP:4.108(W/W)
5.20kW/17,700BTU/h
6.70kW/22,900BTU/h
C
H
AWTZ24LB
Hi-EER: 3.02 (W/W)
Hi-COP: 3.62 (W/W)
7.40kW/25,300BTU/h
8.50kW/29,000BTU/h
C
H
A
B
C
Our unique technology achieved top energy efficiency in the industry.
Rotor plate
Rotor plateElectromagnet
Thin copper wireThin copper wire reduced electric
resistance.
Electromagnet
WORLD FIRST!
6
Nocria®
Ceiling Wall
WORLD FIRST!
B C
A
Area, which confronts magnetic attraction, is very narrow
Area which confronts magnetic attraction is very wide and generates high power.
Rotor plate
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 6
7
Strong vertical air flow provides powerful floor level heating.
Healthy horizontal air flow does not blow cool air directly at the occupants in the room.
*Compared to Inverter Model AST13PSACW. *Compared to Inverter Model AST13PSACW.
Increased heat exchange efficiency
Air is blowndirectly downward
Power diffuser (full open)
Big flap
Increased heat exchange efficiency
Blown out horizontallyPower diffuser
Big flap
Comfortable heating areaApproximately 2.5 times*(Our company comparison) Cooling range
Approximately 1.7 times*(Our company comparison)
No.1Heatingcapacity
Automatic filter clean
Entire filter is cleaned automatically in approximately 2 minutes.
Since the filter is cleaned automatically, energy saving capability
is displayed without regard to the load on the air conditioner.
Energy saving.
If the energy saving effect is maintained, filter cleaning once every
two weeks is effective.
Three exhaustive sterilising and deodorising countermeasures keep the air in the room clean. Antibacterial dust box
Removes dirt and dust by double brushes.Dust collection is approximately twice that
in the past. (Our Company Comparison).Dust box only needs to be emptied
every two years.
STERILISING COUNTER MEASURE
Dirt and dust are thoroughly sterilised by titan apatite filter*
* Displays double the effect of a conventional optical medium
and retains its property for a long time to suck in and remove
approximately 99.99% of cigarette odours and bacteria, etc.
World First! Drives away bacteria and refreshes the air by UV (ultraviolet rays) illumination.
The heat exchanger also uses titan apatite.
Titan apatite attracts bacteria and mould spores that pass
through the filter and suppresses the growth of bacteria.
WORLD FIRST!
D E
F
D
E
F
Remote controller
Frequently used parts are clearly
visible at the centre. The operation
mode can be directly selected.
Inner drying operation prevents growth of mould, fungus and bad odour.
This model is equipped with an inner drying function. After the power
is turned off, the drying operation starts inside the air conditioner.
Covered in Beading
Bacteria grows in beading and causes bad odour.
After operation ends, by pressing the COIL DRY button a 30 minute
speed cleaning operation will commence.
Removes Moisture
Drying operation takes approx. 15 minutes.
Sterilisation
Ozone sterilisation operation takes approx. 15 minutes.
“Inner drying operation” and “ozone sterilising operation” keep the
inside of the air conditioner clean at all times. That’s why air from
the air conditioner is always clean and high efficiency is achieved.
03
03
03
03
WORLD FIRST!
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 7
8
Minute dust particles are thoroughly collected by
electrostatic filter and odours are suppressed
through decomposition by using negatively
charged ions. This filter design allows for high dust
collection whilst maintaining clean odourless air.
INVERTER
PlasmaWall Mounted
Highefficiency
layout
Washable filter
Each time the filter is washed,
it is restored to the same
performance levels as when new.
Plasma air filter mechanism
Original plasma air cleaning unit effectively cleans the air in the room.
Clean Air
Dirty Air
Available only from selected outlets.
ASTB09LD
Hi-EER: 4.252 (W/W
Hi-COP: 4.44 (W/W)
2.60kW/8,900BTU/h
3.60kW/12,300BTU/h
ASTB12LD
Hi-EER: 3.843 (W/W)
Hi-COP: 3.934 (W/W)
3.50kW/11,900BTU/h
4.80kW/16,400BTU/h
ASTB18LD
Hi-EER: 3.022 (W/W)
Hi-COP: 3.609 (W/W)
5.20kW/17,700BTU/h
6.25kW/21,300BTU/h
C
H
C
H
ASTB24LD
Hi-EER: 3.01 (W/W)
Hi-COP: 3.51 (W/W)
7.40kW/25,300BTU/h
8.50kW/29,000BTU/h
C
H
ASTB30LD
Hi-EER: 3.05 (W/W)
Hi-COP: 3.41 (W/W)
8.10kW/27,663BTU/h
9.20kW/31,419BTU/h
C
H
C
H
For ASTB18/24LD
For ASTB09/12LD
For ASTB30LD
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 8
Clean Air
Activated charcoal
disinfecting & deodorising filter
Polyphenol filter
(Grapefruit seed ectract)
Earth conductor
Plasma filter generates ions and ozone.
Electric pole
Electrostatic filter
Dirty Air
Negatively-charged dust, etc. are attracted to the earth
section and are collected by a disinfecting &
deodorising filter.Pet odour and the smell of cigarette smoke are
removed by decomposition
by weak ozone O3.
9
Plasma air cleaner quickly removes small dust particles and odours.
Collects dirt such as...
House dust/Pet fur/Cigarette smoke/Dust
mites/Mould spores and Pollen.
Absorbs odours such as...
Cigarette smoke/Pet odour/Perspiration and Body odour.
Dust collection performance
100
90
80
70
60
50
400 5 10 15 20 10 20 10 2025 30
Time (mins) Time (mins) Time (mins)
Resi
dual
rat
io %
Dust collection efficiency
54.3%
Dust collection efficiency
54.3%
Deodorizing performance
100
80
60
40
20
00 30
Acetic acid
Resi
dual
rat
io %
Removal ratio
82.4%
100
80
60
40
20
00 30
Ammonia
Resi
dual
rat
io %
Removal ratio
92.7%
Sterilisation effect by Polyphenol ceraglaze
Tested by KITAZATO environment science centre Experiment bacteria:Staphylococcus Aures/Escherichia coli Test No. :15-0253. Test condition: at 20 degrees C/24 hour action
Test method: JEM1467 Test room : 1m3, acryl sealed box
Test method: JEM 1417 Test room: 30m3, sealed room
Deodorising performanceDust collection performance
AmmoniaAcetic Acid
The following diagrams illustrate the effect of a 0.1ml
specimen containing bacteria (approx. 107CFU/ml)
being sterilised by polyphenol ceraglaze.
Performance
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 9
10
Energy efficient Fujitsu Comfort. The Fujitsu smart
Inverter range reaches the desired room temperature
faster and then constantly adjusts to maintain perfect
Fujitsu Comfort. With its energy efficiency, it is up to
30% cheaper to run than conventional air conditioners.
INVERTER
ASTA07JC*
Hi-EER: 3.68(W/W)
2.10kW/7,200BTU/h
ASTA09JC*
Hi-EER: 3.518(W/W)
2.60kW/8,900BTU/h
ASTA12JC*
Hi-EER: 3.150(W/W)
3.50kW/11,900BTU/h
ASTA09LC
Hi-EER: 3.963(W/W)
Hi-COP: 4.261(W/W)
2.60kW/8,900BTU/h
3.60kW/12,300BTU/h
ASTA12LC
Hi-EER: 3.801(W/W)
Hi-COP: 3.869(W/W)
3.50kW/11,900BTU/h
4.80kW/16,400BTU/h
ASTA18LC
Hi-EER: 3.022(W/W)
Hi-COP: 3.61(W/W)
5.20kW/17,700BTU/h
6.25kW/21,300BTU/h
C
C
H
C
H
C
C
C
H
For ASTA07/09
For ASTA12
For ASTA18LC
ASTA24LC
Hi-EER: 3.01 (W/W)
Hi-COP: 3.516 (W/W)
7.40kW/25,300BTU/h
8.50kW/29,000BTU/h
ASTA30LC
Hi-EER: 2.989 (W/W)
Hi-COP: 3.385(W/W)
8.00kW/27,300BTU/h
9.00kW/30,700BTU/h
C
H
C
H
Wall Mounted
* Cooling only models not shown. Design differs.
ASTA24JC†
Hi-EER: 3.21 (W/W)
7.10kW/24,200BTU/h
ASTA30JC†
Hi-EER: 3.01 (W/W)
8.00kW/27,300BTU/h
ASTA34JC†
9.70kW/33,100BTU/h
†Cooling only
C
C
C
ASTA18JC†
Hi-EER: 3.69 (W/W)
5.20kW/17,700BTU/hC
For ASTA30/34
For ASTA18/24
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 10
11
Air conditioner filter features
Easy maintenance Inner drying operation
Apple-catechin filter
Fine dust, invisible mould spores and harmful micro organisms are
absorbed onto the filter by static electricity and further growth is inhibited
and deactivated by the polyphenol ingredient extracted from apples.
Long-life* Ion deodorisation filter
The filter deodorises by powerfully decomposing absorbed
odours using the oxidising filter and reducing effects of ions
generated by the ultra-fine-particle ceramic. (*The filter
can be used for approximately 3 years if it is washed
under water to restore its surface action when it is dirty.)
00
4080
120160
30 60 120
(ppm)
(min)
Ammonia
With no filter
New filter
00
4080
120160
30 60 120
(ppm)
(min)
Trimethylamine
With no filter
New filter
00
4080
120160
30 60 120
(ppm)
(min)
Hydrogen sulfate
With no filter
New filter
Testing organization : Environmental Sanitary Inspection Center Test method : Deodorization Test
Deodorizing effect (Odour reduction rate)
Since the front panel is easy to remove, maintenance is
also easy.
This model is equipped with an inner drying function. After the power is
turned off, the drying operation starts inside the air conditioner. This
helps prevent the growth of mould and bacteria inside the indoor unit.
During dew condensation Approx. 20 mins Drying
ASTA07/09/12/18LC ASTA24/30LC
All DC
DC Fan Motor
V-PAM control
V-PAM technology makes a compressor more powerful.
DC scroll compressor
More compact compared with conventional model
A
B
C
A
B
C
High efficiencylayout
Large air flow and
quiet operation by
new air flow path
New 3-row heatexchange system
3
1
2
Back viewFront view
Conventional model New modelCompact design
Unit: mm H320 x W1,120 x D220 H900 x W900 x D350 H320 x W998 x D228 H578 x W790 x D315
70kg 44kg
Clean Air
Dirty Air Ion deodorisation filter Apple-catechin filter
Deodorising effect (odour reduction rate)
Testing organisation : Environmental Sanitary Inspection Center Test method : Deodorisation Test
Heat exchange capacities 20% upcompared to conventional models
The following features apply to ASTA24LC model
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 11
INVERTER Cassette
AUTA18LAL
5.20kW/17,700BTU/h
6.00kW/20,500BTU/h
C
H
AUTA24LAL
7.10kW/24,200BTU/h
8.00kW/27,300BTU/h
AUT30L
8.50kW/29,000BTU/h
10.0kW/34,100BTU/h
C
H
C
H
Condensate pump lift to 400mm (AUTA18L/24L), 800mm (AUT30L)
Compact size (AUTA18L/24L)
AUT30L
Duct connection (For AUT30L only)
Easy maintenance (AUT30L)
AUTA18L/24L
AUT30L
Wired type (with weekly/setback timer)
For AUTA18/24L
For AUT30L
Compact grille fits common ceiling
panel (590 x 590mm).
Long-life filter
Wired Remote Controller with
Thermo Sensor
• Room temperature sensor selection
• Temperature SET BACK timer
• Group control system
• Child-proof lock
• Dual remote controllers <optional>
• Hot start <for heating>
The control box is easily accessible for maintenance work.
Wide opening for easy access. Detachable, washable filter
and intake grille. Wide opening and long-life filter. High
efficiency, long-life filter extends the cleaning cycle.
ABTA18LAT
5.20kW/17,700BTU/h
6.00kW/20,500BTU/h
C
H
ABTA30LBT*
8.5kW/29000BTU/h
10.0kW/34100BTU/h
C
H
ABTA24LAT
7.10kW/24,200BTU/h
8.00kW/27,300BTU/h
C
H
For ABTA18L
For ABTA24L
Long life filter
Conditioned air
can be distributed
by means of a
distribution duct.
Distribution duct
Distribution duct
Fresh air
Fresh air can be introduced through this opening.
Fresh air can be introduced
through thisopening
Distribution duct Fresh air
Distributionduct
INVERTER Universal Floor/CeilingThe Inverter Universal Floor/Ceiling single room split system units are highly efficient.
Two-way
Two-way AUT30L
One-way
One-wayAUT30L
Condensate pump
12
For ABTA30LBT
590
590
(Unit: mm)
*Ceiling type only
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 12
13
The New Fujitsu Inverter Multi System is ideal where an
individual indoor unit is required in each room, i.e., a living
room and 3 bedrooms. The Multi Systems allow one
outdoor unit to be connected up to a wide variety of 2,
3 or 4 indoor units including Wall Mounted, Floor/Ceiling
Console and Cassette, depending on the model.
INVERTER Multi System 2 Room/4 Room
Easy installation and easy maintenanceCompact Design
Outdoor unit: AOT30LMAW4
Current model New model Existing model New model
H835 x W900 x D330mm
Outdoor unit: AOT24LMAM2. Maintenance has been improved
by making attachment and detachment of the top panel easy.
d l N M d l
DC Inverter Multi Type System
(The illustration below is an example of the AOT30LMAW4)
This inverter system is equipped with a state of the art DC twin rotary compressor.
It can reach the room temperature you set 15% quicker than conventional models and precisely maintain it at a difference of just 0.5°C.
Advanced DC twin rotary compressor makes operation at high power and high efficiency a reality.
Select any type of indoor unit you like to suit the conditionsof your room
Example illustration of system configuration
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 13
Wall Mountedtype (Small Size)
Wall Mountedtype (Large Size)
Cassette type(Compact)
Floor/CeilingUniversal type
ASTA07LACM
ASTA09LACM
AST24LB
AUTA18LAL
ABTA24LAT
ABTA18LAT
ABT14LBAUT14LB
AUT12LB
AO
T3
0L
M4
AO
T2
4L
M2
AOT30LM4
AOT24LM21 outdoor unit to 2 indoor unitsThe total capacity of the indoor units that can be connected is 4.4 - 8.7kW(15,000 - 30,000BTU)
1 outdoor unit to 3–4 indoor unitsThe total capacity of the indoor units that can be connected is 7.9 - 14.3kW(27,000 - 49,000BTU)
2.3kW
2.7kW
3.5kW
4.2kW
5.2kW
6.3kW
6.8kW
(7,900BTU)
(9,200BTU)
(11,900BTU)
(14,300BTU)
(17,800BTU)
(21,500BTU)
(23,200BTU)
ASTA12LACM
ASTA18LACM
14
AUT12L/14L/18LABT14L/18L/24LASTA07L/09L/12L/18LAST24LBAJ
AOT24LMAM2
5.80kW/19,800BTU/h
6.40kW/21,900BTU/h
AUT12/14/18LB
Cassette (Compact) Type
C
H
ABT14/18/24LB
Universal Type
ASTA07/09/12/18LACM
Wall Mounted Type
AST24LB
Wall Mounted Type
Refer to dealer for selection chart.
AOT30LMAW4
8.00kW/27,300BTU/h
9.60kW/32,800BTU/h
C
H
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 14
15
AOT19F (AST9FMBD x2)
2.90kW/9,900BTU/h
AOT19U (AST9UMBD x2)
2.85kW/9,700BTU/h
3.25kW/11,100BTU/h
C
H
C
AOT19FAOT19U
CONVENTIONAL 2 Room Multi System
The Fujitsu Inverter System is equipped with
a state of the art DC twin rotary compressor.
It can reach the room temperature you set
15%* quicker than conventional models and
precisely maintain it at a difference of just
0.5°C. Advanced DC twin rotary compressor
makes operation at high power and high
efficiency a reality.
Energy savings over 1 year
The high efficiency DC Inverter Multi System offers
energy saving operation and approximately 50%
higher efficiency than a constant-speed multi system.
Improved Inverter cooling ratio prevents a drop in
capacity when operating under load conditions.
The air conditioner's output is stabilised at the optimum
setting within the range from maximum to minimum to
match the load, which is affected by factors such as the
room temperature and the number of people present.
Each indoor unit can be operated independently. That is,
on/off, temperature, air movement and time clock operation
can all be controlled from their own wireless remote.
DC Twin Rotary Compressor Independent Control
Stable and Comfort
High Energy Efficiency
DC Inverter Multi System
Constant-Speed Multi System
DC Inver
Constant
50%Off
Approx.
Compressor COP100
90
80(%)
2 4 6 8
Cooling Capacity(kW)
COP
10 12
Comparison of cooling efficiency of DC compressor(against AC compressor)
AC Twin RotalyDC Twin Rotary
Comparison of cooling efficiency of DC compressor (against AC compressor)
DC twin rotarycompressor
*Depends on roomsize and heat load.
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 15
SPECIFICATIONS
16
Type INVERTER
Model No.Indoor Unit AWTZ14LBC AWTZ18LBC AWTZ24LBC
Outdoor Unit AOTZ14LBC AOTZ18LBC AOTZ24LBT
Reverse Cycle System Yes Yes Yes
Cooling CapacityWatts 4200 5200 7400
BTU/h 14300 17700 25300
Range Watts 900-5300 900-5900 900-8000
BTU/h 3100-18100 3100-20100 3100-27300
Heating CapacityWatts 6000 6700 8500
BTU/h 20500 22900 29000
Range Watts 900-9100 900-9700 900-10600
BTU/h 3100-31000 3100-33100 3100-36200
Power Supply Volts 240 240 240
Phase-Frequency Ph - Hz 1-50 1-50 1-50
Power Supply Attachment Indoor Indoor Outdoor
Plug Size (If Applicable) Amps 15 amp plug 15 amp plug NA
Cooling Amps 4.3 6.6 10.4
Running CurrentRange Amps Max 8.5 Max 8.5 Max 12.5
Heating Amps 5.7 6.9 9.9
Range Amps Max 14 Max 14 Max 17.5
Cooling Watts 1020 1580 2460
InputRange Watts 90-1750 90-2000 110-2620
Heating Watts 1350 1630 2350
Range Watts 90-2950 90-3200 110-3680
Moisture Removal l/hr 2.1 2.8 3
E.E.R. Cooling 4.12 3.289 3.02
C.O.P. Heating 4.44 4.108 3.62
Star RatingCooling ������ ����� ����Heating ������ ������ �����
Fan Speeds 5 5 5
Air Circulation High l/s 261 261 261
Compressor Type Rotary Rotary Scroll
Height mm 250 250 250
I.U. Width mm 899 899 899
Depth mm 298 298 298
Dimensions Net Weight kg 13.5 13.5 14
and Weights Height mm 578 578 830
O.U. Width mm 790 790 900
Depth mm 300 300 330
Net Weight kg 39 39 62
I.U. Sound Pressure Level dBA@1mtr 46 46 47
O.U. Sound Pressure Level dBA@1mtr 47 48 53
O.U. Sound Power Level dBA 65 65 68
Refrigerant R410A R410A R410A
Connection Pipe SizesGas mm 12.7 12.7 15.88
Liquid mm 6.35 6.35 6.35
Pre Charged Length Metre 15 15 15
Minimum Pipe Length Metre 3 3 3
Maximum Pipe Length Metre 20 20 30
Maximum Pipe Height Metre 15 15 20
Pipe Connection Methods Flare Flare Flare
Outdoor operating Temp.Cooling Degrees C -10 to 43 -10 to 43 -10 to 43
Heating Degrees C -15 to 24 -15 to 24 -15 to 24
NOCRIAINVERTER PLASMAINVERTER
ASTB09LDC ASTB12LDC ASTB18LDC ASTB24LDC ASTB30LDC
AOTS09LDC AOTS12LDC AOTS18LDC AOTS24LDC AOTS30LDT
Yes Yes Yes Yes Yes
2600 3500 5200 7400 8100
8900 11900 17700 25300 27663
500-3700 900-4300 900-5700 900-8000 2900-9000
1700-12600 3100-14700 3100-19400 3100-27300 9900-30700
3600 4800 6250 8500 9200
12300 16400 21300 29000 31419
500-6100 900-6700 900-9100 900-10600 2200-11000
1700-20800 3100-22900 3100-31000 3100-36200 7500-37500
240 240 240 240 240
1-50 1-50 1-50 1-50 1-50
Indoor Indoor Indoor Outdoor Outdoor
10 amp plug 15 amp plug 15 amp plug NA NA
2.8 4.1 7.3 10.4 11.2
Max 6 Max 7 Max 9 Max 12 Max 18.5
3.7 5.3 7.4 10.2 11.4
Max 8.5 Max 10 Max 13.5 Max 17.5 Max 18.5
610 910 1720 2460 2660
250-1380 250-1610 90-2000 110-2620 580-4300
810 1220 1730 2420 2700
250-1960 250-2300 90-2660 110-3680 500-4300
1.3 1.8 2.8 3 3
4.252 3.843 3.022 3.01 3.05
4.44 3.934 3.61 3.51 3.41
������ ������ ���� ���� ���������� ������ ����� ����� ������
4 4 4 4 4
165 176 194 325 325
Rotary Rotary Rotary Scroll Rotary
283 283 283 320 320
790 790 790 998 998
230 230 230 228 228
9.5 9.5 9.5 14 14
540 540 578 578 830
790 790 790 790 900
290 290 300 315 330
34 36 40 44 62
40 41 42 47 49
48 49 50 53 55
65 67 68 69 69
R410A R410A R410A R410A R410A
9.52 9.52 12.7 15.88 15.88
6.35 6.35 6.35 6.35 9.52
15 15 15 15 20
3 3 3 3 5
20 20 20 30 50
15 15 15 20 30
Flare Flare Flare Flare Flare
-10 to 43 -10 to 43 -10 to 43 -10 to 43 -10 to 43
-15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 16
INVERTER
ASTA07JCC ASTA09JCC ASTA12JCC ASTA18JCC ASTA24JCC ASTA30JCC ASTA34JCC ASTA09LCC ASTA12LCC ASTA18LCC ASTA24LCC ASTA30LCC
AOTR07JCC AOTR09JCC AOTR12JCC AOTR18JCC AOTR24JCC AOTR30JCT AOTR34JCT AOTR09LCC AOTR12LCC AOTR18LCC AOTR24LCC AOTR30LCT
No No No No No No No Yes Yes Yes Yes Yes
2100 2600 3500 5200 7100 8000 9700 2600 3500 5200 7400 8000
7200 8900 11900 17700 24200 27300 33100 8900 11900 17700 25300 27300
500-2800 500-3300 900-4000 900-6000 900-8000 2900-9000 2900-10000 500-3600 900-4300 900-5700 900-8000 2900-9000
1700-9600 1700-11300 3100-13700 3100-20500 3100-27300 9900-30700 9900-34100 1700-12300 3100-14700 3100-19400 3100-27300 9900-30700
- - - - - - - 3600 4800 6250 8500 9000
- - - - - - - 12300 16400 21300 29000 30700
- - - - - - - 500-5300 900-6700 900-9100 900-10600 2200-11000
- - - - - - - 1700-18100 3100-22900 3100-31000 3100-36200 7500-37500
240 240 240 240 240 240 240 240 240 240 240 240
1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50
Indoor Indoor Indoor Outdoor Outdoor Outdoor Outdoor Indoor Indoor Indoor Outdoor Outdoor
10 amp plug 10 amp plug 10 amp plug NA NA NA NA 10 amp plug 15 amp plug 15 amp plug NA NA
2.7 3.4 4.9 6.1 9.4 11.2 16.4 3 4.1 7.3 10.4 11.7
Max 6 Max 6 Max 7 Max 9 Max 11.5 Max 16.5 Max 18.5 Max 6 Max 7 Max 9 Max 12 Max 17
- - - - - - - 3.9 5.4 7.4 10.2 11.6
- - - - - - - Max 8.5 Max 10 Max 13.5 Max 17.5 Max 19
570 740 1110 1410 2210 2660 3900 655 920 1720 2460 2660
250-1140 250-1310 250-1410 900-2000 110-2550 580-3920 580-4400 250-1380 250-1610 90-2000 110-2620 580-3600
- - - - - - - 845 1240 1730 2420 2640
- - - - - - - 250-1960 250-2300 90-2660 110-3680 500-4300
1.0 1.3 1.8 2.8 3 3 4.5 1.3 1.8 2.8 3 3.4
3.68 3.51 3.15 3.69 3.21 3.01 2.49 3.963 3.801 3.022 3.011 2.989
- - - - - - - 4.261 3.869 3.61 3.516 3.385
������ ������ ������ ������ ����� ���� ���� ������ ������ ���� ���� ����- - - - - - - ������ ������ ����� ����� ������4 4 4 4 4 4 4 4 4 4 4 4
149 149 150 250 306 306 314 165 176 194 305 305
Rotary Rotary Rotary Scroll Scroll Rotary Rotary Rotary Rotary Rotary Scroll Rotary
257 257 275 320 320 320 320 275 275 275 320 320
808 808 790 998 998 998 998 790 790 790 998 998
187 187 215 228 228 228 228 215 215 215 228 228
8 8 8.5 14 14 14 14 9 9 9 14 14
540 540 540 620 620 830 830 540 540 578 578 830
660 660 790 790 790 900 900 660 790 790 790 900
290 290 290 298 298 330 330 290 290 300 315 330
30 30 36 40 40 58 58 32 37 40 44 62
38 38 38 43 47 49 50 41 42 42 47 47
48 48 49 50 56 53 54 48 49 50 52 53
65 65 67 65 72 69 70 65 67 68 68 69
R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
9.52 9.52 9.52 12.7 15.88 15.88 15.88 9.52 9.52 12.7 15.88 15.88
6.35 6.35 6.35 6.35 6.35 9.52 9.52 6.35 6.35 6.35 6.35 9.52
7.5 7.5 7.5 15 15 20 20 15 15 15 15 20
3 3 3 3 3 3 3 3 3 3 3 5
15 15 15 30 30 30 30 20 20 20 30 50
10 10 10 20 20 20 20 15 15 15 20 30
Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare
18 to 43 18 to 43 18 to 43 18 to 43 18 to 43 18 to 43 18 to 43 10 to 43 10 to 43 -10 to 43 -10 to 43 -10 to 43
- - - - - - - -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
WALL MOUNTED
S ll Wi d M iS ll Wi d Mi i
1000
2000
Wat
ts (
W)
Square Metres (M2)0 10 15 20 25 30 35 40 45 50 55 60 65 70
3000
4000
5000
6000
7000
8000
Small Window Minimum
Large Window Minimum
1000
2000
Wat
ts (
W)
Square Metres (M2)0 10 15 20 25 30 35 40 45 50 55 60 65 70
3000
4000
5000
6000
7000
8000
1000
2000
Wat
ts (
W)
Square Metres (M2)0 10 15 20 25 30 35 40 45 50 55 60 65 70
3000
4000
5000
6000
7000
8000
S ll Wi d M iS ll Wi d Mi i
1000
2000
Wat
ts (
W)
Square Metres (M2)0 10 15 20 25 30 35 40 45 50 55 60 65 70
3000
4000
5000
6000
7000
8000
CEILING INSULATED WINDOW NOT FACING WEST
CEILING INSULATED WINDOW FACING WEST
CEILING UNINSULATED WINDOW NOT FACING WEST
CEILING UNINSULATED WINDOW FACING WEST
Room SizeChartCheck yourrequirements
Small Window Maximum
Large Window Maximum
b k
Please refer to disclaimers on back cover
For future improvement, specifications& designs of product are subject tochange without notice. Heating andcooling capacities are based on AS/NZS 3823.
CoolingIndoor Temp: 27°C DB/19°C WB Outdoor Temp: 35°C DB
HeatingIndoor Temp: 20°C DBOutdoor Temp: 7°C DB /6°C WB
Note: The appropriate load will vary according to the region. Use only as a guide.
17
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 17
18
-- WALL MOUNTED FLOOR/CEILING CASSETT
ASTA07LACM ASTA09LACM ASTA12LACM ASTA18LACM AST24LBAJ ABT14LBAJ ABT18LBAJ ABT24LBAJ AUT12LBAB AUT14LBA
- - - - - - - - - -
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
2300 2700 3500 5000 6800 4200 5200 6800 3500 4000
7900 9200 11900 17100 23200 14300 17800 23200 11900 13700
1500-2700 1500-3200 1500-3700 1800-5600 7400 5000 6000 7400 3800 4500
5100-9200 5100-10900 5100-12600 6100-19100 25300 17200 20500 25300 13000 15400
2700 3300 4000 6000 8200 4800 6000 8200 3800 4300
9200 11300 13700 20500 28000 16400 20500 28000 13000 14700
1500-3300 1500-4200 1500-4800 1600-7100 9000 5700 7100 9000 4500 5200
5100-11300 5100-14300 5100-16400 5500-24200 30700 19500 24200 30700 15400 17800
240 240 240 240 240 240 240 240 240 240
1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50
Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoo
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
0.8 1 1.2 2 3 1.5 1.7 2.5 1.3 1.5
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
4 4 4 4 4 3 3 3 3 3
139 153 161 183 283 177 216 244 152 152
- - - - - - - - - -
275 275 275 275 320 199 199 199 235 235
790 790 790 790 1120 990 990 990 580 580
215 215 215 215 220 655 655 655 580 580
9 9 9 9 16 28 28 28 18 18
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
35 38 39 45 47 36 43 48 42 42
- - - - - - - - - -
- - - - - - - - - -
R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
9.52 9.52 9.52 12.7 15.88 12.7 12.7 15.88 9.52 12.7
6.35 6.35 6.35 6.35 9.52 6.35 6.35 9.52 6.35 6.35
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
25 25 25 25 25 25 25 25 25 25
10 10 10 10 10 10 10 10 10 10
Flare Flare Flare Flare Flare Flare Flare Flare Flare Flare
- - - - - - - - - -
- - - - - - - - - -
Type
Model No.Indoor Unit
Outdoor Unit
Reverse Cycle System
Cooling CapacityWatts
BTU/h
MaximumWatts
BTU/h
Heating CapacityWatts
BTU/h
MaximumWatts
BTU/h
Power Supply Volts
Phase-Frequency Ph - Hz
Power Supply Attachment
Plug Size (If Applicable)
Cooling Amps
Running Current Range Amps
Heating Amps
Range Amps
Cooling Watts
InputRange Watts
Heating Watts
Range Watts
Moisture Removal l/hr
E.E.R. Cooling
C.O.P. Heating
Star RatingCooling
Heating
Fan Speeds
Air Circulation High l/s
Compressor Type
Height mm
I.U. Width mm
Depth mm
Dimensions Net Weight kg
and Weights Height mm
O.U. Width mm
Depth mm
Net Weight kg
I.U. Sound Pressure Level dBA@1mtr
O.U. Sound Pressure Level dBA@1mtr
O.U. Sound Power Level dBA
Refrigerant Type
Connection Pipe SizesGas mm
Liquid mm
Pre Charged Length Metre
Minimum Pipe Length Metre
Max. Pipe Length (per unit) Metre
Maximum Pipe Length Metre
Maximum Pipe Height Metre
Pipe Connection Methods
Outdoor operating Temp.Cooling Degrees C
Heating Degrees C
MULTI SYSTEM 2/4 ROOMINVERTER
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 18
CONVENTIONAL
AST9FMBDx2 AST9UMBDx2
AOT19FSCV2 AOT19USCV2
No Yes
2900 2850
9900 9700
- -
- -
- 3250
- 11100
- -
- -
240 240
1-50 1-50
Outdoor Outdoor
NA NA
4.7 4.6
NA NA
- 4.6
NA NA
1080 990
NA NA
- 1030
NA NA
1 1
2.69 2.83
- 3.16
- -
- -
4 4
144 130
Rotary Rotary
257 257
808 808
187 187
8 8
700 700
900 900
330 330
61 63
40 36
53 52
65 65
R410A R410A
9.52 9.52
6.35 6.35
7.5 7.5
5 5
NA NA
15 15
8 8
Flare Flare
18 to 43 10 to 43
- -5 to 24
INVERTER
AUTA18LAL AUTA24LAL AUT30LUAS
AOTA18LACL AOTA24LACL AOT30LNAWL
Yes Yes Yes
5200 7100 8500
17700 24200 29000
900-5900 900-8000 3000-10000
3100-20100 3100-27300 10200-34100
6000 8000 10000
20500 27300 34100
900-7500 900-9100 3000-11200
3100-25600 3100-31000 10200-38200
240 240 240
1-50 1-50 1-50
Outdoor Outdoor Outdoor
NA NA NA
6.8 9.3 12
Max 9.0 Max 9.0 4.6-14.6
7 9.3 11.9
Max 12.5 Max 13.5 4.3-14.6
1620 2280 2860
90-2070 90-2610 1080-3500
1660 2210 2840
90-2520 90-2800 1000-3500
2.2 2.7 3
3.21 3.11 2.906
3.61 3.61 3.505
����� ������ ��������� ����� �����
4 4 3
188 258 444
Twin Rotary Twin Rotary Twin Rotary
245 (49) 245 (49) 296
570 (70) 570 (70) 830
570 (70) 570 (70) 830
15 (2.6) 17 (2.6) 37
578 578 830
790 790 900
300 315 330
40 44 64
38 49 48
50 52 55
65 68 68
R410A R410A R410A
12.7 15.88 15.88
6.35 6.35 9.52
15 15 15
3 3 5
NA NA NA
25 30 50
15 20 30
Flare Flare Flare
-10 to 46 -10 to 46 -10 to 43
-15 to 24 -15 to 24 -10 to 24
INVERTER
ABTA18LAT ABTA24LAT ABTA30LBT
AOTA18LACL AOTA24LACL AOTA30LBTL
Yes Yes Yes
5200 7100 8500
17700 24200 29000
900-5900 900-8000 2800-10000
3100-20100 3100-27300 9500-34100
6000 8000 10000
20500 27300 34100
900-7500 900-9100 2700-11200
3100-25600 3100-31000 9200-38200
240 240 240
1-50 1-50 1-50
Outdoor Outdoor Outdoor
NA NA NA
6.8 9.3 11.6
Max 8.6 Max 11.3 Max 17.0
7 9.3 12.2
Max 10.3 Max 11.6 Max 17.0
1620 2280 2650
Max 2040 Max 2690 Max 3880
1660 2210 2710
Max 2450 Max 2760 Max 3880
2 2.7 2.5
3.21 3.11 3.21
3.61 3.61 3.69
����� ������ ���������� ����� �������
4 4 4
216 277 461
Twin Rotary Twin Rotary Twin Rotary
199 199 240
990 990 1660
655 655 700
27 27 46
578 578 830
790 790 900
300 315 330
40 44 62
44 49 45
50 52 55
65 68 69
R410A R410A R410A
12.7 15.88 15.88
6.35 6.35 9.52
15 15 20
3 3 5
NA NA NA
25 30 50
15 20 30
Flare Flare Flare
-10 to 46 -10 to 46 -15 to 46
-15 to 24 -15 to 24 -15 to 24
WALL MOUNTED MULTI
19
CASSETTE OUTDOOR
T12LBAB AUT14LBAB AUT18LBAB - -
- - - AOT30LMAW4 AOT24LMAM2
Yes Yes Yes Yes Yes
3500 4000 4300 8000 5800
11900 13700 14700 27300 19800
3800 4500 5200 10100 7800
3000 15400 17800 34500 26600
3800 4300 5000 9600 6400
3000 14700 17100 32800 21900
4500 5200 6300 12000 9000
15400 17800 21150 41000 30700
240 240 240 240 240
1-50 1-50 1-50 1-50 1-50
utdoor Outdoor Outdoor Outdoor Outdoor
- - - NA NA
- - - 9.3 7.3
- - - Max 15.7 Max 12.2
- - - 10.1 6.9
- - - Max 15.7 Max 12.2
- - - 2220 1730
- - - Max 3580 Max 2920
- - - 2400 1640
- - - Max 3580 Max 2920
1.3 1.5 2 - -
- - - 3.6 3.35
- - - 4 3.9
- - - - -
- - - - -
3 3 3 - -
152 152 172 916 805
- - - Twin Rotary Twin Rotary
235 235 235 - -
580 580 580 - -
580 580 580 - -
18 18 18 - -
- - - 835 650
- - - 900 830
- - - 330 320
- - - 68 56
42 42 44 - -
- - - 51 49
- - - 64 62
R410A R410A R410A R410A R410A
9.52 12.7 12.7 2 x 9.52, 2 x 12.7 1 x 12.7, 1 x 9.52
6.35 6.35 6.35 4 x 6.35 2 x 6.35
- - - 50 30
- - - 5 5
- - - 25 20
25 25 25 Max Total 70 Max Total 30
10 10 10 10 10
Flare Flare Flare Flare Flare
- - - 0 to 43 0 to 43
- - - -10 to 24 -10 to 24
OM FLOOR/CEILINGCASSETTE
FG0050_RETAIL08.qxd 27/8/08 1:11 PM Page 19