DuMaster D-480Unattended and flexible protein determination
The DuMaster D-480 enables unattended and flexible determination of nitrogen or protein according to the Dumas combustion method. The short analysis time of approximately 4 minutes per sample, coupled with the built-in autosampler accommodating up to 120 sam-ples, makes this analyzer perfectly suitable for high throughput without supervision.
Safe and convenient Exchange catalysts safely and add or remove samples at any time
Unattended and fastRun up to 120 samples without interaction or supervision
Cost effective Reduce your costs per analysis
Safe and convenient Exchange catalysts safely and add or remove samples at any time
DuMaster D-480Key features and advantages
«The DuMaster D-480 delivers the accuracy required whilst being easy to use. This combined with the low unit cost per sample fulfills our commercial needs.»Jon Griffin, Public Analyst, Kent Scientific Services, UK
Random access
Choose between 60 and 120 positions autosampler plate with random access at any time
Availability of carrier gas
No CO2 trap needed thanks to the use of lower priced carbon dioxide as carrier gas instead of helium
Precise detection
Use of reliable and stable thermal conductivity detector integrated in a space-saving instrument
Minimized maintenance
Convenient slide out furnace for an easy exchange of all tubes
Sample preparation tools
Specific equipment for a tight packaging of solid and liquid samples
Easy to use software
Create a complete sample sequence and test the system using the integrated leak test
Thanks to the new Regainer-Reductor technology, the absorption capacity of an excess of oxygen, dosed during the combustion process, is radically increased.
The regainer 1 in the post combustion tube binds the oxygen and can be refilled easily without changing the complete tube filling.
In the pre-filled reductor tube 2 the nitric oxides are reduced to nitrogen and the reduction agent is automatically regenerated. Use this tube for up to 2’000 determinations.
1 2
1159
2814
E e
n 16
03 /
Tec
hnic
al d
ata
are
sub
ject
to c
hang
e w
ithou
t not
ice
/ Q
ualit
y S
yste
ms
ISO
90
01 T
he E
nglis
h ve
rsio
n is
the
orig
inal
lang
uage
ve
rsio
n an
d se
rves
as
bas
is fo
r al
l tra
nsla
tions
into
oth
er la
ngua
ges.
www.buchi.com/dumaster Quality in your hands
D-480:
Unattended and fast
∙ Rapid analysis times of approximately 4 minutes per sample ∙ High sample throughput due to fast and automatic autosampler ∙ Unattended overnight operation of up to 300 samples per day ∙ Continuous operation thanks to stable calibration over months
Cost effective
∙ Low costs per sample thanks to: ∙ high degree of automation ∙ low-priced carbon dioxide as carrier gas as opposed to helium ∙ up to 95% savings of oxygen due to automated oxygen control
∙ Maximized up times as result of innovative post combustion and Regainer-Reductor technology ∙ Highest productivity with 2,000 analyses per one pre-filled reduction tube
Safe and convenient
∙ Maximum safety: no contact with harmful chemicals or risk of burns ∙ Large sample volume (up to 1 g or 1 mL) analysis thanks to efficient multi-step gas drying ∙ Random access of samples at any time (no batch processing required) ∙ Remote assistance and troubleshooting over the internet
Complete your portfolio
Your most important benefits
Mixer B-400Grinding and homogenization
Analytical balancesML54, MS105-DUWeighing
KjelMaster SystemK-375 / K-376 / K-377Steam distillation, titration and auto sampling
NIRMaster™IP54FT-NIR spectroscopy with ingress protection