Electromagnetic Flowmeters
Electromagneticflowmeters
2
Electromagnetic flowmeters from KROHNEare designed to measure the volumetric flowrate of liquids (with and without solids contents),pulps, pastes and slurries in practically allindustrial sectors.The only requirement is that the processproduct should have a defined minimumelectrical conductivity.
KROHNE is of course your competent partner in other sectors of instrumentationand control.
Ultra-modern electronic equipment andstate-of-the-art production processes,combined with an efficient quality management system,ensure consistently high precision and quality in variable-area flowmeters,CORIMASS mass flow meters,level measuring devices, as well as engineering solutions & systems and communications engineering.
The principle of electromagnetic flowmetering has various specialadvantages over other methods of measurement:
� Measurement largely independent of pressure,density,temperature,viscosity and flow profile
� Short inlet and outlet runs
� Unimpeded tube cross-section
� No additional pressure drop
� No moving parts
� Any installation position
� Turn-down ratio 100:1
Backgro
und
Wate
r
Wastew
ater
Abrasive
,co
rrosive
andho
t produ
cts
Non-contact
measurem
entκ
≥0.05
µS/cm
Food,
Beve
rage,
Pharm
aceutical
High
Pre
ssure
and special
conne
ctions
Integral
and Rem
ote
Rem
ote
Calibration
/M
easuringP
rinciple
Sizing /
instal-latio
n guide
sO
rderingguide
Signal co
nverte
r
3Background 3.1
Application
KROHNE electromagnetic flowmeters are to be found in many industrial sectors and applications.Just a small selection:
� Chemical industry
� Water and wastewater
� Hydraulic transport,liquid products with up to 50% solids content
� Paper and woodpulp production
� Pharmaceutical
� Food and beverages
� Filling and dispensing processes
� Highly abrasive slurries
� High-pressure industrial processes
� Partially filled pipelines
and many, many other applications in other industries
FIT and FORGET !
All electromagnetic flowmeters are delivered ready for operation.Install the flowmeter in the pipeline,make the electrical connection, that's it.
Always one step ahead with KROHNE
This highly accurate measurement technology is available with integrallyor remote mounted converter, some with measuring errors of less than0.2% of the measured value.The primary head is installed in the pipeline, while the signal converterfor signal processing is remote mounted in a field housing or 19" plug-in unit.In the integral system, the signal converter is mounted in a housingwith high protection category directly on the primary head.
With meter sizes of DN2.5 - 3000 / 1/10" - 120",measurements can be carried out from 2 l/h to 300 000m3/h and more.Most of the devices are approved for use in hazardous locations.Various materials are available for the measuring tube,liner and electrodes of the flowmeters for most applications.
4 Background 3.1
Backgro
und
Wate
r
Wastew
ater
Abrasive
,co
rrosive
andho
t produ
cts
Non-contact
measurem
entκ
≥0.05
µS/cm
Food,
Beve
rage,
Pharm
aceutical
High
Pre
ssure
and special
conne
ctions
Integral
and Rem
ote
Rem
ote
Calibration
/M
easuringP
rinciple
Sizing /
instal-latio
n guide
sO
rderingguide
Signal co
nverte
r
Production and calibration
All electromagnetic flowmeters from KROHNE meet the requirements of CE directives and EMC guidelines.Fabrication and production shops are certified to ISO 9001.
At KROHNE, all electromagnetic flowmeters are calibrated by direct comparison of volumes,the most accurate calibration method of all.The KROHNE calibration rigs are the world's biggest and most accurate, and are certified to EN 45 001.Measurement uncertainty is less than 0.03% of the measured value for meter sizes up to DN 3000 / 120" and above.
5Background 3.1
Device selection
The following tables will help you to find the right device for your partic-ular application.
Pages 6 and 7 comprise the various flowmeters (primary heads) andpages 8 and 9 the associated signal converters.
The easiest way is to note down the operating data relevant to yourapplication. Each additional feature will narrow down the number ofsuitable devices. For example:
Feature Choice of device (see table for No.)
� Meter size DN150 or 6" 1, 2, 3, 4, 10, 11, 12
� Operating temperature = 60°C/140°F 1, 2, 3, 4, 10, 11, 12
� Operating pressure = 40 bar/psig 1, 4, 11, 12
� Process product = a chemical 4, 12
� Measuring error ≤ 0.3% of measured value 4, 12
� Version = K (compact system) 4
Primary head = No. 4 ALTOFLUX IFS 4000 K
Signal converter IFC 020 K or IFC 090 K
Signal converter selected from pages 8 and 9 by the same method.
Sizes from _ to _ / connections
DN 2.5 1/10"DN 10 3/8"DN 25 1"DN 40 11/2"DN 50 2"DN 80 3"DN 100 4"DN 125 5"DN 150 6"DN 200 8"DN 250 10"DN 300 12"DN 1800 72"DN 3000 120"
flange connectionsflangeless designsanitary connections
Full-scale range from _ to _
6 l/h 0.02USGal/min85l/h 0.30USGal/min
530l/h 2.30USGal/min19m3/h 90 USGal/min35m3/h 150 USGal/min50m3/h 220 USGal/min
220m3/h 950 USGal/min340m3/h 1500 USGal/min760m3/h 3360 USGal/min
1350m3/h 9000 USGal/min2100m3/h 10000 USGal/min3050m3/h 14100 USGal/min
109000m3/h 507000 USGal/min305000m3/h 1400000 USGal/min
Application fields (e.g.)
chemicalswater and sewagepartially filled pipespharmaceutical, sanitarybatching (1-10 s)very abrasive slurrieshigh pressuregeneral purpose
Background 3.16
Aquaflux K, F, EEcoflux IFS 1000 K, F, E
Altoflux IFS 2000 F, EAltoflux IFS 4000 K, F, E
Profiflux IFS 5000 K, F, EVariflux IFS 6000 K, F, E
Capaflux IFM 5080 K-CAPBatchflux - Batchcontrol
Tidalflux IFM 4110 PFAltoflux IFS 2005 F
Altoflux IFS 4005 FAltoflux M 900 F
K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” 3) see Data sheet “TIDAFLUX IFM4110PF” 4) see Data sheet “ALTOFLUX IFS 2000 or 4000”
Electromagnetic flowmeters
Selection guide
1 2 3 4 5 6 7 8 9 10 11 12
4) 4)
4)
4)
Backgro
und
Wate
r
Wastew
ater
Abrasive
,co
rrosive
andho
t produ
cts
Non-contact
measurem
entκ
≥0.05
µS/cm
Food,
Beve
rage,
Pharm
aceutical
High
Pre
ssure
and special
conne
ctions
Integral
and Rem
ote
Rem
ote
Calibration
/M
easuringP
rinciple
Sizing /
instal-latio
n guide
sO
rderingguide
Signal co
nverte
r
Background 3.1 7
Product temperature range
>+180°C >+356°F on request+180°C +356°F max. remote+140°C +284°F max. compact+120°C +248°F+100°C +212°F+ 90°C +194°F+ 60°C +140°F
0°C + 32°F- 5°C + 23°F- 20°C - 4°F- 25°C - 13°F- 60°C - 75°F min.
Operation pressure
≤ 1500bar ≤20000psig on request≤ 40bar ≤ 580psig≤ 16bar ≤ 230psig≤ 10bar ≤ 150psig
Elecrical conductivity
≥ 0.05µS/cm capacitive signal pickup≥ 5.00µS/cm≥ 20.00µS/cm water≥ 50.00µS/cm
Approvals
EEx versionsFM Factory Mutual3AFML Weihenstephan
Combined with _ _ _ _
Signal converter ErrorIFC 010 K, F ≤ ± 0.5 % of MVIFC 020 K ≤ ± 0.3 % of MVIFC 020 F, E ≤ ± 0.3 % of MVIFC 090 K ≤ ± 0.3 % of MVIFC 090 F ≤ ± 0.3 % of MVIFC 110 F ≤ ± 0.3 (0.2) % of MVIFC 210 E ≤ ± 0.3 (0.2) % of MVSC 150 F ≤ ± 0.4 % of MVIFC 012 K / 014 K ≤ ± 0.4/0.2/0.1% of MV 1)
IFC 090 K-CAP ≤ ± 0.5 % of MV 2)
IFC 110 PF ≤ ± 1.0 % of MV 3)
(MV=Measured Volume)
Aquaflux K, F, EEcoflux IFS 1000 K, F, E
Altoflux IFS 2000 F, EAltoflux IFS 4000 K, F, E
Profiflux IFS 5000 K, F, EVariflux IFS 6000 K, F, E
Capaflux IFM 5080 K-CAPBatchflux - Batchcontrol
Tidalflux IFM 4110 PFAltoflux IFS 2005 F
Altoflux IFS 4005 FAltoflux M 900 F
1 2 3 4 5 6 7 8 9 10 11 12
K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” 3) see Data sheet “TIDAFLUX IFM4110PF” 4) see Data sheet “ALTOFLUX IFS 2000 or 4000”
4) 4)
Electromagnetic flowmeters
Selection guide
Standard equipment and approvals
outputs- / inputsforward / reverse flowlow-flow cutofflimit contactloop test fiunctiongalvanic isolationovervoltage protectionautomatic range changeexternal totalizer resetexternal range selectormagnetic sensors (option)empty pipe detection
EEx versionsEEx, intrinsically safeFM Factory MutualCustody transfer (in preparation)
Flow measurement, e.g.
liquids, pastessludges and slurries, contents ≤ 3%
contents ≤ 5%contents ≤ 30%
pulsating flow, 200 pulses/minbatching processpaper and pulp industriesdredging industryhydraulic transport (ore dressing)partially filled pipes, only IFC 110 PFcapacitive signal pickup, only IFC 090 K-CAP
Background 3.18
IFC 010 K, FIFC 020 K, F, E
IFC 090 K, F + IFC 090 K–CAPIFC 110 F + IFC 110 PF
IFC 210 EIFC 012 K / 014 K
SC 150 F
1 2 3 4 5 6 7
Signal converters for electromagnetic flowmeters
Selection guide
K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” for IFC 090 K-CAP 3) see Data sheet “TIDAFLUX IFM4110PF” for IFC 110 PF
Backgro
und
Wate
r
Wastew
ater
Abrasive
,co
rrosive
andho
t produ
cts
Non-contact
measurem
entκ
≥0.05
µS/cm
Food,
Beve
rage,
Pharm
aceutical
High
Pre
ssure
and special
conne
ctions
Integral
and Rem
ote
Rem
ote
Calibration
/M
easuringP
rinciple
Sizing /
instal-latio
n guide
sO
rderingguide
Signal co
nverte
r
Background 3.1 9
Current output
0 / 4 - 20 mA0 / 4 - 20 mA and others
Pulse output
0-10 pulses/s (scalable)0-100 Hz, 0-1 000 Hz for full-scale0-1 000 Hz for full-scale, scalable0-10 000 Hz for full-scale, scalable
Status (binary) output
1 for e.g. flow direction, indicationsmax. 2 e.g. for flow direction, limits4 for e.g. flow direction, automatic range change
Control input
max. 2 for e.g. totalizer reset, hold outputs
Interface
HART®, RS 485 (standard)HART®, smart, RS 485 (option)HART® (option)ProfibusFieldbusothers on request
Power consumption
≤ 3 W≤ 5 W≤ 5 VA / 4 W≤ 10 VA / 8 W≤ 11 VA / 14 W≤ 15 VA / 15 W≤ 50 VA
Power supply
24, 48, 100-240 V AC, 48-63 Hz24 V DC85-264 V AC, 48-63 Hz24 V AC / DC100-240 V AC, 48-63 Hz
IFC 010 K, FIFC 020 K, F, E
IFC 090 K, F + IFC 090 K–CAPIFC 110 F + IFC 110 PF
IFC 210 EIFC 012 K / 014 K
SC 150 F
1 2 3 4 5 6 7
Signal converters for electromagnetic flowmeters
Selection guide
K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” for IFC 090 K-CAP 3) see Data sheet “TIDAFLUX IFM4110PF” for IFC 110 PF
2) 3) 1)
Characterization
Signal converter, see page 8Electrical conductivity Full scale range(0.3 - 12m/s) / (1 - 40ft/s)Meter size Pressure ratingProduct temperatureProtection category (IEC 529/EN 60 529)Materials measuring section/liner
electrodes
Hazardous European Standardduty versions* FM-Factory Mutual
Fields of applicationIndustry
Abrasion resistance
Chemical resistance of liner... with alkalis, e. g. NaOH
... with acids, e. g. HNO3
ECOFLUXIFM 1010 KIFM 1020 KIFM 1080 K
� Flangeless version� Rugged measuring tube with
stainless steel reinforcedTeflon® PFA liner
� Particularly economical� Wide field of application
IFC 010 K, IFC 020 K or IFC 090 K≥ 5µS/cm (water ≥ 20µS/cm)85liter/h - 760m3/h0.3 - 3 360US Gal/minDN10 - 150 and 3/8” - 6”up to 16bar/230psig,– 25 to + 120°C/– 13 to + 248°FIP 67, equivalent to NEMA 6Teflon® PFA
Hastelloy C4
noClass I, II, III, Div 2**
environmental engineering, water and sewage, agriculture,batching of fertilizers and liquids feeds
very good
NaOH up to 70% at 20°C/68°F
HNO3 up to 65% at 20°C/68°F
(limited by electrode material)
AQUAFLUX010 K020 K080 K
� Flanged connections� Steel housing� µP-signal converter in plastics
housing� Available with or without
indicator� Particularly economical
IFC 010 K, IFC 020 K or IFC 090 K ≥ 20µS/cm85liter/h - 33 000m3/h0.3 - 156 000US Gal/minDN10 - 1000 and 3/8” - 40”up to 40bar/580psig– 5 to + 90°C/+ 23 to + 194°FIP 67, equivalent to NEMA 6≥ DN25 / ≥ 1” hard rubber≤ DN20 / ≤ 3/4” Teflon® PTFEHastelloy C4
nono
environmental engineering,water and sewage
higher than required for the applications in question
NaOH up to 50% at 20°C/68°F
HNO3 up to 5% at 20°C/68°F
ALTOFLUXIFM 4010 KIFM 4020 KIFM 4080 K
� Flanged connections� Steel housing� Teflon® PFA liner, reinforced with
stainless steel mesh, for highchemical, vacuum and abrasionresistance
IFC 010 K, IFC 020 K or IFC 090 K≥ 5µS/cm (water ≥ 20µS/cm)85liter/h - 33 000m3/h0.3 - 156 000US Gal/minDN10 - 1000 and 3/8” - 40”up to 40bar/580psig– 60 to + 140°C/– 75 to + 284°FIP 67, equivalent to NEMA 6Teflon® PFA, Teflon® PTFE,ETFE (Tefzel), (others on request)Hastelloy C4, platinum, titanium,stainless steel 1.4571/316 Ti.EEx dqe or dq ib IIC T3 . . . T6 Class I, II, III, Div 1, 2
the ”workhorse” for water, sewage and waste water, chemicals,paper, cellulose, ore dressing
dependent on liner material, very highwith Teflon® PFA
all concentrations with Teflon® PFA orPTFE linersall concentrations with Teflon® PFA or PTFE liners
(select materials for grounding ringsand gaskets for process compatibility)
Background 3.110
Integral systems of electromagnetic flowmeters
Backgro
und
Wate
r
Wastew
ater
Abrasive
,co
rrosive
andho
t produ
cts
Non-contact
measurem
entκ
≥0.05
µS/cm
Food,
Beve
rage,
Pharm
aceutical
High
Pre
ssure
and special
conne
ctions
Integral
and Rem
ote
Rem
ote
Calibration
/M
easuringP
rinciple
Sizing /
instal-latio
n guide
sO
rderingguide
Signal co
nverte
r
PROFIFLUXIFM 5010 KIFM 5020 KIFM 5080 K
� Flangeless version� Stainless steel housing� The only precision flowmeter
with flow profile-optimizing measuring tube
� Influence on measuring accuracy from temperature,viscosity, pressure and flow profile is extremely slight
IFC 010 K, IFC 020 K or IFC 090 K≥ 5µS/cm (water ≥ 20µS/cm)6liter/h - 340m3/h0.02 - 1 500US Gal/min 0.75 – 54ft/sDN 2.5 - 100 and 1/10” - 4”up to 40bar/580psig– 60 to + 140°C/– 75 to + 284°FIP 67, equivalent to NEMA 6fused aluminium oxide, 99.7% Al2O3
Cermet, platinum
EEx dme ib IIC T3 . . . T6Class I, II, III, Div 2**
all applications requiring extremely high measuring stability under arduous operating conditions.
extremely high
NaOH up to 50% at 50°C/122°F
HNO3 up to 99% at 90°C/194°F, HF(hydrofluoric acid), all concentr. up to50°C/122°F (select materials for grounding ringsand gaskets for process compatibility)
VARIFLUXIFM 6010 KIFM 6020 KIFM 6080 K
� Various sanitary/flangedconnections
� Stainless steel housing� FDA approved Teflon® PFA liner,
vacuum resistant, CIP and SIPcleaning facilitated by uniquemetal reinforcement of the PFA
� Largest assortment of sanitaryconnections
IFC 010 K, IFC 020 K or IFC 090 K ≥ 5µS/cm (water ≥ 20µS/cm)6 liter/h - 220m3/h0.3 - 950US Gal/minDN2.5 - 80 and 1/10” - 3”up to 40bar/580psig– 60 to + 140°C/– 75 to + 284°FIP 67, equivalent to NEMA 6Teflon® PFA
Hastelloy C4, platinum, titaniumstainless steel 1.4571/316 TiEEx dme ib IIC T3 . . . T6Class I, II, III, Div 1, 2**
food and beverage, pharmaceutical,cosmetics, chemical
high
all concentrations
all concentrations
(select materials for grounding ringsand gaskets for process compatibility)
CAPAFLUXIFM 5080 K-CAP
� Precision flowmeter� With capacitive signal pickup
(electrodes not in contact withthe product)
� Minimum required electricalconductivity only 0.05µS/cm(water: 1µS/cm)
� No need for selection of electrode material, liner hashigh chemical resistance
� No electrochemical effects atthe electrodes, also suitable 7for the most difficult chemicalprocesses
� Not affected by electricallyinsulating deposits
� Abrasion resistant, suitable forproducts with high solids contents
� No crevices, no blind spots:sanitary
� With flow profile-optimizing measuring tube
IFC 090 K-CAP (similar to IFC 090 K)≥ 0,05µS/cm (water ≥ 1µS/cm)530liter/h - 340m3/h2.3 - 1 500US Gal/minDN25 - 100 and 1” - 4”up to 40bar/580psig– 20 to + 100°C/– 4 to + 212°F 5IP 67, equivalent to NEMA 6fused aluminium oxide, 99.7% Al2O3
capacitive electrodes,not wettedyes,yes, in preparation
all sectors where what counts are leak-tightand crevice-free tubes for flow-metering themost difficult products, including low-conductivity and deposit-forming productsextremely high
NaOH up to 50% at 50°C/122°F
HNO3 up to 99% at 90°C/194°F, HF(hydro-fluoric acid), all concentr. up to50°C/122°F
BATCHFLUXBATCHCONTROL
� Excellent measuring accuracyand repeatability
� Dimensionally stable Al2O3 measuring tube, suitable for SIPand CIP cleaning
� Crevice-free CERMET electrodes� Specially developed for use on
filling machines � Fast and accurate volumetric
filling processes for even thesmallest amounts
� Batching times > 1s� Low power consumption, < 3W� Also available with integrated
batch controllerIFC 011 K (similar to IFC 010 K)≥ 5µS/cm (water ≥ 20µS/cm)6 liter/h - 50m3/h0.02 - 220US Gal/minDN2.5 - 40 and 1/10” - 11/2”up to 10bar/150psig– 25 to + 140°C/– 13 to + 284°FIP 67, equivalent to NEMA 6fused aluminium oxide, 99.7% Al2O3
Cermet, platinum
nono
batching of fertilizers and liquid feeds
extremely high
NaOH up to 50% at 50°C/122°F
HNO3 up to 99% at 90°C/194°F
(select materials for grounding rings andelectrodes for process compatibility)
11Background 3.1
Characterization
Magnetic systemElectrical conductivity Full scale range(0.3 - 12m/s) / (1 - 40ft/s)Meter size Pressure ratingProduct temperatureProtection category (IEC 529/EN 60 529)
Materialsmeasuring section/liner
electrodes
Approvals/TestsHazardous duty version: European-Standard(* in preparation) FM-Factory MutualFood and beverage
Combined with signal converter
(see Pages 8 and 9)Fields of applicationIndustry
Abrasion resistance
Chemical resistance of liner... with alkalis, e. g. NaOH, KOH
... with acids, e. g. HNO3
ECOFLUXIFS 1000 F
� Flangeless version� Rugged measuring tube with
stainless steel reinforcedTeflon® PFA liner
� Particularly economical� Wide field of application
pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)85liter/h - 760m3/h0.3 - 3 360US Gal/minDN10 - 150 and 3/8” - 6”up to 16bar/230psig– 25 to + 120°C/– 13 to + 248°FIP 67, equivalent to NEMA 4/4X
Teflon® PFA
Hastelloy C4
nopending Div 2**no
IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F
environmental engineering water andsewage, agriculture, batching of fertilizers and liquids feeds
very good
NaOH up to 70% at 20°C/68°F
HNO3 up to 65% at 20°C/68°F
(limited by electrode material)
(limited by electrode material)
AQUAFLUXF
� Flanged connections� Steel housing� Liner of Polypropylene, NSF-
approved Polyurethane liner and KTW approved hard rubber quality
� Particularly economical
pulsed DC field≥ 20µS/cm85liter/h - 305 000m3/h0.3 - 1 400 000US Gal/minDN10 - 3000 and 3/8” - 120”up to 40bar/580psig– 5 to + 90°C/+ 23 to + 194°FIP 67, equivalent to NEMA 6
≥ DN25 / ≥ 1” hard rubber≤ DN20 / ≤ 3/4” Teflon® PTFEHastelloy C4
nonono
IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F
environmental engineering,water and sewage
higher than required for the applications in question
NaOH up to 50% at 20°C/68°F
HNO3 up to 5% at 20°C/68°F
ALTOFLUXIFS 4000 FIFS 4005 F
� Flanged connections� Steel housing� Teflon® PFA liner, reinforced with
stainless steel mesh, for highchemical, vacuum and abrasionresistance
� IFS4000F for largelyhomogeneous liquids,slurries, pastes
� IFS 4005 F for liquids with highsolids content
pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)85 liter/h - 305 000 m3/h0.3 - 1 400 000 US Gal/minDN 10 - 3000 and 3/8” - 120”up to 40bar/580psig– 60 to + 180°C/– 76 to + 356°FIP 67, equivalent to NEMA 6
Teflon® PFA, Teflon® PTFE,ETFE (Tefzel)Hastelloy C4, platinum, titanium,stainless steel 1.4571/316 Ti.
EEx eq ib IIC T3 . . . T6Class I, II, III, Div 1, 2no
IFS 4000 F: IFC 010 F / IFC 020 F, EIFC 090 F IFC 110 FIFS 4005 F: SC 150 F
the ”workhorse” for water, sewage andwaste water, chemicals, paper,cellulose, ore dressing
dependent on liner material, very highwith Teflon® PFA
all concentrations with Teflon® PFA orPTFE linersall concentrations with Teflon® PFA or PTFE liners
(select materials for grounding ringsand gaskets for process compatibility)
12 Background 3.1
Primary heads of electromagnetic flowmeters
Backgro
und
Wate
r
Wastew
ater
Abrasive
,co
rrosive
andho
t produ
cts
Non-contact
measurem
entκ
≥0.05
µS/cm
Food,
Beve
rage,
Pharm
aceutical
High
Pre
ssure
and special
conne
ctions
Integral
and Rem
ote
Rem
ote
Calibration
/M
easuringP
rinciple
Sizing /
instal-latio
n guide
sO
rderingguide
Signal co
nverte
r
PROFIFLUXIFS 5000 K
� Flangeless (sandwich) design� Stainless steel housing� The only precision flowmeter
with flow profile-optimizingmeasuring tube
� Influence on measuring accuracy from temperature,viscosity, pressure and flow profile is extremely slight
pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)6liter/h - 340m3/h0.02 - 1 500US Gal/minDN 2.5 - 100 and 1/10” - 4”up to 40bar/580psig– 60 to + 180°C/– 76 to + 356°FIP 67, equivalent to NEMA 6
fused aluminium oxide, 99.7% Al2O3
Cermet, platinum
EEx me ib IIC T3 . . . T6Class I, II, III, Div 2**yes
IFS 5000 F: IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F
all applications requiringextremely high measuring stability under arduous operating conditions.
extremely high
NaOH up to 50% at 50°C/122°F
HNO3 up to 99% at 90°C/194°F, HF(hydrofluoric acid), all concentr. up to50°C/122°F
(select materials for grounding ringsand gaskets for process compatibility)
ALTOFLUXIFS 2000 FIFS 2005 F
� Flanged connections� Steel housing � Measuring tube made of Al2O3
almost as hard as diamonds� High measurement and long-term
stability, even with highly abrasiveproducts
� IFS 2000 F: for largely homogeneousliquids, slurries, pastes
� IFS 2005 F: for liquids with high(and coarse-grained) solids content
pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)19liter/h - 2100m3/h84 - 930US Gal/minDN 150 - 250 and 6” - 10”up to 16bar/230 psig– 60 to + 120°C/– 76 to + 248°FIP 65, equivalent to NEMA 4/4X
fused aluminium oxide, 99.7 % Al2O3
Hastelloy C4, platinumstainless steel 1.4571/316 Ti
noClass I, II, III, Div. 2no
IFS 2000 F: IFC 020 F, EIFC 090 FIFC 110 FIFS 2005 F: SC 150 F
aluminium, ore mining,heat measurement
extremely high
NaOH up to 50% at 50°C/122°F
HNO3 up to 99 % at 90°C/194°F
(select materials for grounding rings,electrodes and gaskets for processcompatibility)
VARIFLUXIFS 6000 F
� Various sanitary/flanged connec-tions, stainless steel housing
� FDA approved Teflon® PFA liner, vac-uum resistant, CIP and SIP cleaning facilitated by uniquemetal reinforcement of the PFA
� Largest selection of sanitary con-nections
pulsed DC field ≥ 5µS/cm (water ≥ 20µS/cm)6 liter/h - 220m3/h0.02 - 950US Gal/minDN 2.5 - 80 and 1/10” - 3”up to 40bar/580psig – 60 to + 180°C/– 76 to + 356°FIP 67, equivalent to NEMA 6
Teflon®-PFAFDA approvedHastelloy C4, platinum, titanium,stainless steel 1.4571/316 Ti
EEx me ib IIC T3 . . . T6*Class I, II, III, Div. 1, 2*Dairy and Research CenterWeihenstephan, A3
IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F
food and beverage, pharmaceutical,cosmetics, chemical
high
all concentrations
all concentrations
(select materials for connections andelectrodes for process compatibility)
TIDAFLUXIFS 4000 PF
� Designed for partially filled pipelines� Excellent measuring accuracy, also
for low levels, through the integratedcapacitive level measuring system
� Saves installation and maintenanceof sluice underpasses
pulsed DC field≥ 50µS/cm35liter/h - 100 000m3/h0.2 - 500 000US Gal/minDN200 - 1800 and 8” - 24”up to 10bar/150psig– 5 to + 60°C/+ 23 to + 140°FIP 67, equivalent to NEMA 6
Irathan, 12mm/0.47”
Hastelloy C4
Ex N, Zone 2 (option) in preparationno
IFC 110 PF
sewage in partially filled
pipelines
very high
NaOH up to 10% at 30°C/86°F
HNO3 up to 5% at 20°C/68°F
13Background 3.1
14 Background 3.1
Characterization
Application
Special features
Magnetic field excitation
Full-scale range
Outputs CurrentPulse
Status
Control input
Interfaces (option)
Power supply
Power consumption
Error limits overall system
Standard equipment
Other versionsHazardous-duty versionEuropean StandardFM (Factory Mutual)
For custody transfer
IFC 010 K IFC 020 KIFC 010 F IFC 020 F
IFC 020 E
� IFC 010 K/IFC 020 K of integral design� IFC 010 F/IFC 020 F in field housing� Signal processing by microprocessor,
good dynamic response. Basic version with dis-play/totalizing and control unit with plain-textoperator prompting,all functions/data can be set.IFC 020: display/totalizing, HART®/RS 485 interface, higher field current,IFC 020 E 19” plug-in version.
For liquids, pastes, sludges and slurries with up to 3%solids content, IFC 020 for pulsating flows with up toapprox. 200 pump lifts/min, and batching processes.
Identical electronic module for remote-system andcompact flowmeters = simplified stocking of spares.Modular electronic unit easily upgradable, easilyadaptable to meet additional requirementsBidirectional pulsed DC field.
0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20 mA0 – 10 pulses/s (scalable), 0 – 100 Hz0 – 1000 Hz for full-scale rangeBinary output, e.g. for flow direction error indication
–
HART®, smart, RS 485; Profibus in preparation
24, 48, 100 – 240V AC, 48 – 63Hz and 24 V DC
5VA / 4W
± 0.5% of measured value
Low-flow cutoffForward/reverse flow measurementLimit contactTest function for converter and receiverinstrumentsGalvanic isolationOvervoltage protector (supply powerand all outputs)
––
–
IFC 090 KIFC 090 F
� IFC 090 K of integral design� IFC 090 F in field housing� Signal processing by microprocessor,
very good dynamic response.Basic version with display/totalizing and controlunit with clear-text operator prompting, all func-tions/data can be set (also with magnetic sen-sors without opening the housing)
Liquids, pastes, sludges and slurries with solids content up to 5%, also for pulsating flows up toapprox. 200 pump lifts/min, and batching processes
Outstanding repeatability and dynamic responsethrough higher field frequency and field current.Modular electronic unit, easily upgradable, easilyadaptable to meet additional requirements.Bidirectional pulsed DC field.
0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20 mA, etc.0 – 1000 pulses/s (scalable) for full-scale range
Binary output, e.g. for direction of flow error indication, range selection
Binary outputs switch-selectable to the control input, e.g.set outputs and totalizer to zero, external range change, etc.HART®, smart, RS 485; Profibus; Fieldbus
24, 48, 100 – 240V AC, 48 – 63Hz and 24V DC
10VA / 8W
± 0.3% of measured value
Low-flow cutoff, Forward/reverse flow measurement,Automatic range change Limit contacts, External rangeselector, External totalizer resetTest function for converter and receiver instruments,Galvanic isolationOvervoltage protector (supply power and all inputsand outputs)
in preparationin preparation
in preparation
Signal converters for electromagnetic flowmeters
Backgro
und
Wate
r
Wastew
ater
Abrasive
,co
rrosive
andho
t produ
cts
Non-contact
measurem
entκ
≥0.05
µS/cm
Food,
Beve
rage,
Pharm
aceutical
High
Pre
ssure
and special
conne
ctions
Integral
and Rem
ote
Rem
ote
Calibration
/M
easuringP
rinciple
Sizing /
instal-latio
n guide
sO
rderingguide
Signal co
nverte
r
15Background 3.1
IFC 110 F IFC 110 PF
� Signal converter in field housing� Signal processing by microprocessor,
outstanding interference rejection,very good dynamic response
� Basic version without display orcontrol unit
� Option: display/totalizing and controlunit with plain-text operator prompting,all functions/data can be set.
� IFC 110 PF for TIDALFLUX IFS 4000 PF
Liquids, pastes, sludges and slurries with solids con-tents up to 5%, also for pulsating flows up to approx.200 pump lifts/min, and batching processes
3 status indication outputs and 2 control inputs alloweasy, flexible system integration. Modular electronicunit, easily upgradable, with unassigned slots for add-on boardBidirectional pulsed DC field, field.
0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20mA, etc.0 – 10 000 pulses/s (scalable)
4 binary outputs, e.g. for flow direction,error indication, automatic range change
2, e.g. totalizer reset, hold outputs, set outputs tozero, testHART®, smart, RS 485; Profibus in preparation
85 – 264V AC, 48 – 63 Hz and 24V DC/AC
15VA / 15W
± 0.3% of measured value (option: 0.2%)
Low-flow cutoff, Forward/reverse flow measurement,Automatic range change, Limit contacts, Externalrange selection, External totalizer reset, Function testof converter and receiver instruments,Galvanic isolation Overvoltage protector (supply powerand all inputs and outputs)
in preparationin preparation
in preparation
SC 150 F
� Signal converter in field housing for wall mounting� Signal processing by microprocessor,
outstanding interference rejection, through highfield frequency and field current, very good measuring stability despite high frequency.
� Option: magnetic sensors for setting all data without opening the housing
Liquids, pastes, slurries, sludges with solids contentsin excess of 30%, e.g. paper and pulp industry,hydraulic conveyance (ore dressing), dredging industry
Heavy-duty electronic module, Excellent measuringsignals, Outstanding repeatability through high fieldcurrent,Designed for toughest process conditionsBidirectional, pulsed high-power DC field.
0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20mA, etc.0 – 10 000 pulses/s (scalable)
Binary output, e.g. for direction of flow,error indication
–
RS 485
100 – 240V AC, 48 – 63Hz
approx. 50VA
± 0.4% of measured value
Low-flow cutoff, Forward/reverse flow measurementAutomatic range change, Limit contacts,Galvanic isolation
––
–
Characterization
Application
Special features
Magnetic field excitation
Full-scale range
Outputs CurrentPulse
Status
Control input
Interfaces (option)
Power supply
Power consumption
Error limits overall system
Standard equipment
Other versionsHazardous-duty versionEuropean StandardFM (Factory Mutual)
For custody transfer