Transcript

Variable area flowmeters

Vortex flowmeters

Flow controllers

Electromagnetic flowmeters

Ultrasonic flowmeters

Mass flowmeters

Level measuring instruments

Communications engineering

Engineering systems & solutions

GR/PRINTO

7.02324.21.00© KROHNE 04/2001 C 31 0000 02 E

Electromagnetic Flowmeters

Electromagneticflowmeters

2

Electromagnetic flowmeters from KROHNEare designed to measure the volumetric flowrate of liquids (with and without solids contents),pulps, pastes and slurries in practically allindustrial sectors.The only requirement is that the processproduct should have a defined minimumelectrical conductivity.

KROHNE is of course your competent partner in other sectors of instrumentationand control.

Ultra-modern electronic equipment andstate-of-the-art production processes,combined with an efficient quality management system,ensure consistently high precision and quality in variable-area flowmeters,CORIMASS mass flow meters,level measuring devices, as well as engineering solutions & systems and communications engineering.

The principle of electromagnetic flowmetering has various specialadvantages over other methods of measurement:

� Measurement largely independent of pressure,density,temperature,viscosity and flow profile

� Short inlet and outlet runs

� Unimpeded tube cross-section

� No additional pressure drop

� No moving parts

� Any installation position

� Turn-down ratio 100:1

Backgro

und

Wate

r

Wastew

ater

Abrasive

,co

rrosive

andho

t produ

cts

Non-contact

measurem

entκ

≥0.05

µS/cm

Food,

Beve

rage,

Pharm

aceutical

High

Pre

ssure

and special

conne

ctions

Integral

and Rem

ote

Rem

ote

Calibration

/M

easuringP

rinciple

Sizing /

instal-latio

n guide

sO

rderingguide

Signal co

nverte

r

3Background 3.1

Application

KROHNE electromagnetic flowmeters are to be found in many industrial sectors and applications.Just a small selection:

� Chemical industry

� Water and wastewater

� Hydraulic transport,liquid products with up to 50% solids content

� Paper and woodpulp production

� Pharmaceutical

� Food and beverages

� Filling and dispensing processes

� Highly abrasive slurries

� High-pressure industrial processes

� Partially filled pipelines

and many, many other applications in other industries

FIT and FORGET !

All electromagnetic flowmeters are delivered ready for operation.Install the flowmeter in the pipeline,make the electrical connection, that's it.

Always one step ahead with KROHNE

This highly accurate measurement technology is available with integrallyor remote mounted converter, some with measuring errors of less than0.2% of the measured value.The primary head is installed in the pipeline, while the signal converterfor signal processing is remote mounted in a field housing or 19" plug-in unit.In the integral system, the signal converter is mounted in a housingwith high protection category directly on the primary head.

With meter sizes of DN2.5 - 3000 / 1/10" - 120",measurements can be carried out from 2 l/h to 300 000m3/h and more.Most of the devices are approved for use in hazardous locations.Various materials are available for the measuring tube,liner and electrodes of the flowmeters for most applications.

4 Background 3.1

Backgro

und

Wate

r

Wastew

ater

Abrasive

,co

rrosive

andho

t produ

cts

Non-contact

measurem

entκ

≥0.05

µS/cm

Food,

Beve

rage,

Pharm

aceutical

High

Pre

ssure

and special

conne

ctions

Integral

and Rem

ote

Rem

ote

Calibration

/M

easuringP

rinciple

Sizing /

instal-latio

n guide

sO

rderingguide

Signal co

nverte

r

Production and calibration

All electromagnetic flowmeters from KROHNE meet the requirements of CE directives and EMC guidelines.Fabrication and production shops are certified to ISO 9001.

At KROHNE, all electromagnetic flowmeters are calibrated by direct comparison of volumes,the most accurate calibration method of all.The KROHNE calibration rigs are the world's biggest and most accurate, and are certified to EN 45 001.Measurement uncertainty is less than 0.03% of the measured value for meter sizes up to DN 3000 / 120" and above.

5Background 3.1

Device selection

The following tables will help you to find the right device for your partic-ular application.

Pages 6 and 7 comprise the various flowmeters (primary heads) andpages 8 and 9 the associated signal converters.

The easiest way is to note down the operating data relevant to yourapplication. Each additional feature will narrow down the number ofsuitable devices. For example:

Feature Choice of device (see table for No.)

� Meter size DN150 or 6" 1, 2, 3, 4, 10, 11, 12

� Operating temperature = 60°C/140°F 1, 2, 3, 4, 10, 11, 12

� Operating pressure = 40 bar/psig 1, 4, 11, 12

� Process product = a chemical 4, 12

� Measuring error ≤ 0.3% of measured value 4, 12

� Version = K (compact system) 4

Primary head = No. 4 ALTOFLUX IFS 4000 K

Signal converter IFC 020 K or IFC 090 K

Signal converter selected from pages 8 and 9 by the same method.

Sizes from _ to _ / connections

DN 2.5 1/10"DN 10 3/8"DN 25 1"DN 40 11/2"DN 50 2"DN 80 3"DN 100 4"DN 125 5"DN 150 6"DN 200 8"DN 250 10"DN 300 12"DN 1800 72"DN 3000 120"

flange connectionsflangeless designsanitary connections

Full-scale range from _ to _

6 l/h 0.02USGal/min85l/h 0.30USGal/min

530l/h 2.30USGal/min19m3/h 90 USGal/min35m3/h 150 USGal/min50m3/h 220 USGal/min

220m3/h 950 USGal/min340m3/h 1500 USGal/min760m3/h 3360 USGal/min

1350m3/h 9000 USGal/min2100m3/h 10000 USGal/min3050m3/h 14100 USGal/min

109000m3/h 507000 USGal/min305000m3/h 1400000 USGal/min

Application fields (e.g.)

chemicalswater and sewagepartially filled pipespharmaceutical, sanitarybatching (1-10 s)very abrasive slurrieshigh pressuregeneral purpose

Background 3.16

Aquaflux K, F, EEcoflux IFS 1000 K, F, E

Altoflux IFS 2000 F, EAltoflux IFS 4000 K, F, E

Profiflux IFS 5000 K, F, EVariflux IFS 6000 K, F, E

Capaflux IFM 5080 K-CAPBatchflux - Batchcontrol

Tidalflux IFM 4110 PFAltoflux IFS 2005 F

Altoflux IFS 4005 FAltoflux M 900 F

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” 3) see Data sheet “TIDAFLUX IFM4110PF” 4) see Data sheet “ALTOFLUX IFS 2000 or 4000”

Electromagnetic flowmeters

Selection guide

1 2 3 4 5 6 7 8 9 10 11 12

4) 4)

4)

4)

Backgro

und

Wate

r

Wastew

ater

Abrasive

,co

rrosive

andho

t produ

cts

Non-contact

measurem

entκ

≥0.05

µS/cm

Food,

Beve

rage,

Pharm

aceutical

High

Pre

ssure

and special

conne

ctions

Integral

and Rem

ote

Rem

ote

Calibration

/M

easuringP

rinciple

Sizing /

instal-latio

n guide

sO

rderingguide

Signal co

nverte

r

Background 3.1 7

Product temperature range

>+180°C >+356°F on request+180°C +356°F max. remote+140°C +284°F max. compact+120°C +248°F+100°C +212°F+ 90°C +194°F+ 60°C +140°F

0°C + 32°F- 5°C + 23°F- 20°C - 4°F- 25°C - 13°F- 60°C - 75°F min.

Operation pressure

≤ 1500bar ≤20000psig on request≤ 40bar ≤ 580psig≤ 16bar ≤ 230psig≤ 10bar ≤ 150psig

Elecrical conductivity

≥ 0.05µS/cm capacitive signal pickup≥ 5.00µS/cm≥ 20.00µS/cm water≥ 50.00µS/cm

Approvals

EEx versionsFM Factory Mutual3AFML Weihenstephan

Combined with _ _ _ _

Signal converter ErrorIFC 010 K, F ≤ ± 0.5 % of MVIFC 020 K ≤ ± 0.3 % of MVIFC 020 F, E ≤ ± 0.3 % of MVIFC 090 K ≤ ± 0.3 % of MVIFC 090 F ≤ ± 0.3 % of MVIFC 110 F ≤ ± 0.3 (0.2) % of MVIFC 210 E ≤ ± 0.3 (0.2) % of MVSC 150 F ≤ ± 0.4 % of MVIFC 012 K / 014 K ≤ ± 0.4/0.2/0.1% of MV 1)

IFC 090 K-CAP ≤ ± 0.5 % of MV 2)

IFC 110 PF ≤ ± 1.0 % of MV 3)

(MV=Measured Volume)

Aquaflux K, F, EEcoflux IFS 1000 K, F, E

Altoflux IFS 2000 F, EAltoflux IFS 4000 K, F, E

Profiflux IFS 5000 K, F, EVariflux IFS 6000 K, F, E

Capaflux IFM 5080 K-CAPBatchflux - Batchcontrol

Tidalflux IFM 4110 PFAltoflux IFS 2005 F

Altoflux IFS 4005 FAltoflux M 900 F

1 2 3 4 5 6 7 8 9 10 11 12

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” 3) see Data sheet “TIDAFLUX IFM4110PF” 4) see Data sheet “ALTOFLUX IFS 2000 or 4000”

4) 4)

Electromagnetic flowmeters

Selection guide

Standard equipment and approvals

outputs- / inputsforward / reverse flowlow-flow cutofflimit contactloop test fiunctiongalvanic isolationovervoltage protectionautomatic range changeexternal totalizer resetexternal range selectormagnetic sensors (option)empty pipe detection

EEx versionsEEx, intrinsically safeFM Factory MutualCustody transfer (in preparation)

Flow measurement, e.g.

liquids, pastessludges and slurries, contents ≤ 3%

contents ≤ 5%contents ≤ 30%

pulsating flow, 200 pulses/minbatching processpaper and pulp industriesdredging industryhydraulic transport (ore dressing)partially filled pipes, only IFC 110 PFcapacitive signal pickup, only IFC 090 K-CAP

Background 3.18

IFC 010 K, FIFC 020 K, F, E

IFC 090 K, F + IFC 090 K–CAPIFC 110 F + IFC 110 PF

IFC 210 EIFC 012 K / 014 K

SC 150 F

1 2 3 4 5 6 7

Signal converters for electromagnetic flowmeters

Selection guide

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” for IFC 090 K-CAP 3) see Data sheet “TIDAFLUX IFM4110PF” for IFC 110 PF

Backgro

und

Wate

r

Wastew

ater

Abrasive

,co

rrosive

andho

t produ

cts

Non-contact

measurem

entκ

≥0.05

µS/cm

Food,

Beve

rage,

Pharm

aceutical

High

Pre

ssure

and special

conne

ctions

Integral

and Rem

ote

Rem

ote

Calibration

/M

easuringP

rinciple

Sizing /

instal-latio

n guide

sO

rderingguide

Signal co

nverte

r

Background 3.1 9

Current output

0 / 4 - 20 mA0 / 4 - 20 mA and others

Pulse output

0-10 pulses/s (scalable)0-100 Hz, 0-1 000 Hz for full-scale0-1 000 Hz for full-scale, scalable0-10 000 Hz for full-scale, scalable

Status (binary) output

1 for e.g. flow direction, indicationsmax. 2 e.g. for flow direction, limits4 for e.g. flow direction, automatic range change

Control input

max. 2 for e.g. totalizer reset, hold outputs

Interface

HART®, RS 485 (standard)HART®, smart, RS 485 (option)HART® (option)ProfibusFieldbusothers on request

Power consumption

≤ 3 W≤ 5 W≤ 5 VA / 4 W≤ 10 VA / 8 W≤ 11 VA / 14 W≤ 15 VA / 15 W≤ 50 VA

Power supply

24, 48, 100-240 V AC, 48-63 Hz24 V DC85-264 V AC, 48-63 Hz24 V AC / DC100-240 V AC, 48-63 Hz

IFC 010 K, FIFC 020 K, F, E

IFC 090 K, F + IFC 090 K–CAPIFC 110 F + IFC 110 PF

IFC 210 EIFC 012 K / 014 K

SC 150 F

1 2 3 4 5 6 7

Signal converters for electromagnetic flowmeters

Selection guide

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” for IFC 090 K-CAP 3) see Data sheet “TIDAFLUX IFM4110PF” for IFC 110 PF

2) 3) 1)

Characterization

Signal converter, see page 8Electrical conductivity Full scale range(0.3 - 12m/s) / (1 - 40ft/s)Meter size Pressure ratingProduct temperatureProtection category (IEC 529/EN 60 529)Materials measuring section/liner

electrodes

Hazardous European Standardduty versions* FM-Factory Mutual

Fields of applicationIndustry

Abrasion resistance

Chemical resistance of liner... with alkalis, e. g. NaOH

... with acids, e. g. HNO3

ECOFLUXIFM 1010 KIFM 1020 KIFM 1080 K

� Flangeless version� Rugged measuring tube with

stainless steel reinforcedTeflon® PFA liner

� Particularly economical� Wide field of application

IFC 010 K, IFC 020 K or IFC 090 K≥ 5µS/cm (water ≥ 20µS/cm)85liter/h - 760m3/h0.3 - 3 360US Gal/minDN10 - 150 and 3/8” - 6”up to 16bar/230psig,– 25 to + 120°C/– 13 to + 248°FIP 67, equivalent to NEMA 6Teflon® PFA

Hastelloy C4

noClass I, II, III, Div 2**

environmental engineering, water and sewage, agriculture,batching of fertilizers and liquids feeds

very good

NaOH up to 70% at 20°C/68°F

HNO3 up to 65% at 20°C/68°F

(limited by electrode material)

AQUAFLUX010 K020 K080 K

� Flanged connections� Steel housing� µP-signal converter in plastics

housing� Available with or without

indicator� Particularly economical

IFC 010 K, IFC 020 K or IFC 090 K ≥ 20µS/cm85liter/h - 33 000m3/h0.3 - 156 000US Gal/minDN10 - 1000 and 3/8” - 40”up to 40bar/580psig– 5 to + 90°C/+ 23 to + 194°FIP 67, equivalent to NEMA 6≥ DN25 / ≥ 1” hard rubber≤ DN20 / ≤ 3/4” Teflon® PTFEHastelloy C4

nono

environmental engineering,water and sewage

higher than required for the applications in question

NaOH up to 50% at 20°C/68°F

HNO3 up to 5% at 20°C/68°F

ALTOFLUXIFM 4010 KIFM 4020 KIFM 4080 K

� Flanged connections� Steel housing� Teflon® PFA liner, reinforced with

stainless steel mesh, for highchemical, vacuum and abrasionresistance

IFC 010 K, IFC 020 K or IFC 090 K≥ 5µS/cm (water ≥ 20µS/cm)85liter/h - 33 000m3/h0.3 - 156 000US Gal/minDN10 - 1000 and 3/8” - 40”up to 40bar/580psig– 60 to + 140°C/– 75 to + 284°FIP 67, equivalent to NEMA 6Teflon® PFA, Teflon® PTFE,ETFE (Tefzel), (others on request)Hastelloy C4, platinum, titanium,stainless steel 1.4571/316 Ti.EEx dqe or dq ib IIC T3 . . . T6 Class I, II, III, Div 1, 2

the ”workhorse” for water, sewage and waste water, chemicals,paper, cellulose, ore dressing

dependent on liner material, very highwith Teflon® PFA

all concentrations with Teflon® PFA orPTFE linersall concentrations with Teflon® PFA or PTFE liners

(select materials for grounding ringsand gaskets for process compatibility)

Background 3.110

Integral systems of electromagnetic flowmeters

Backgro

und

Wate

r

Wastew

ater

Abrasive

,co

rrosive

andho

t produ

cts

Non-contact

measurem

entκ

≥0.05

µS/cm

Food,

Beve

rage,

Pharm

aceutical

High

Pre

ssure

and special

conne

ctions

Integral

and Rem

ote

Rem

ote

Calibration

/M

easuringP

rinciple

Sizing /

instal-latio

n guide

sO

rderingguide

Signal co

nverte

r

PROFIFLUXIFM 5010 KIFM 5020 KIFM 5080 K

� Flangeless version� Stainless steel housing� The only precision flowmeter

with flow profile-optimizing measuring tube

� Influence on measuring accuracy from temperature,viscosity, pressure and flow profile is extremely slight

IFC 010 K, IFC 020 K or IFC 090 K≥ 5µS/cm (water ≥ 20µS/cm)6liter/h - 340m3/h0.02 - 1 500US Gal/min 0.75 – 54ft/sDN 2.5 - 100 and 1/10” - 4”up to 40bar/580psig– 60 to + 140°C/– 75 to + 284°FIP 67, equivalent to NEMA 6fused aluminium oxide, 99.7% Al2O3

Cermet, platinum

EEx dme ib IIC T3 . . . T6Class I, II, III, Div 2**

all applications requiring extremely high measuring stability under arduous operating conditions.

extremely high

NaOH up to 50% at 50°C/122°F

HNO3 up to 99% at 90°C/194°F, HF(hydrofluoric acid), all concentr. up to50°C/122°F (select materials for grounding ringsand gaskets for process compatibility)

VARIFLUXIFM 6010 KIFM 6020 KIFM 6080 K

� Various sanitary/flangedconnections

� Stainless steel housing� FDA approved Teflon® PFA liner,

vacuum resistant, CIP and SIPcleaning facilitated by uniquemetal reinforcement of the PFA

� Largest assortment of sanitaryconnections

IFC 010 K, IFC 020 K or IFC 090 K ≥ 5µS/cm (water ≥ 20µS/cm)6 liter/h - 220m3/h0.3 - 950US Gal/minDN2.5 - 80 and 1/10” - 3”up to 40bar/580psig– 60 to + 140°C/– 75 to + 284°FIP 67, equivalent to NEMA 6Teflon® PFA

Hastelloy C4, platinum, titaniumstainless steel 1.4571/316 TiEEx dme ib IIC T3 . . . T6Class I, II, III, Div 1, 2**

food and beverage, pharmaceutical,cosmetics, chemical

high

all concentrations

all concentrations

(select materials for grounding ringsand gaskets for process compatibility)

CAPAFLUXIFM 5080 K-CAP

� Precision flowmeter� With capacitive signal pickup

(electrodes not in contact withthe product)

� Minimum required electricalconductivity only 0.05µS/cm(water: 1µS/cm)

� No need for selection of electrode material, liner hashigh chemical resistance

� No electrochemical effects atthe electrodes, also suitable 7for the most difficult chemicalprocesses

� Not affected by electricallyinsulating deposits

� Abrasion resistant, suitable forproducts with high solids contents

� No crevices, no blind spots:sanitary

� With flow profile-optimizing measuring tube

IFC 090 K-CAP (similar to IFC 090 K)≥ 0,05µS/cm (water ≥ 1µS/cm)530liter/h - 340m3/h2.3 - 1 500US Gal/minDN25 - 100 and 1” - 4”up to 40bar/580psig– 20 to + 100°C/– 4 to + 212°F 5IP 67, equivalent to NEMA 6fused aluminium oxide, 99.7% Al2O3

capacitive electrodes,not wettedyes,yes, in preparation

all sectors where what counts are leak-tightand crevice-free tubes for flow-metering themost difficult products, including low-conductivity and deposit-forming productsextremely high

NaOH up to 50% at 50°C/122°F

HNO3 up to 99% at 90°C/194°F, HF(hydro-fluoric acid), all concentr. up to50°C/122°F

BATCHFLUXBATCHCONTROL

� Excellent measuring accuracyand repeatability

� Dimensionally stable Al2O3 measuring tube, suitable for SIPand CIP cleaning

� Crevice-free CERMET electrodes� Specially developed for use on

filling machines � Fast and accurate volumetric

filling processes for even thesmallest amounts

� Batching times > 1s� Low power consumption, < 3W� Also available with integrated

batch controllerIFC 011 K (similar to IFC 010 K)≥ 5µS/cm (water ≥ 20µS/cm)6 liter/h - 50m3/h0.02 - 220US Gal/minDN2.5 - 40 and 1/10” - 11/2”up to 10bar/150psig– 25 to + 140°C/– 13 to + 284°FIP 67, equivalent to NEMA 6fused aluminium oxide, 99.7% Al2O3

Cermet, platinum

nono

batching of fertilizers and liquid feeds

extremely high

NaOH up to 50% at 50°C/122°F

HNO3 up to 99% at 90°C/194°F

(select materials for grounding rings andelectrodes for process compatibility)

11Background 3.1

Characterization

Magnetic systemElectrical conductivity Full scale range(0.3 - 12m/s) / (1 - 40ft/s)Meter size Pressure ratingProduct temperatureProtection category (IEC 529/EN 60 529)

Materialsmeasuring section/liner

electrodes

Approvals/TestsHazardous duty version: European-Standard(* in preparation) FM-Factory MutualFood and beverage

Combined with signal converter

(see Pages 8 and 9)Fields of applicationIndustry

Abrasion resistance

Chemical resistance of liner... with alkalis, e. g. NaOH, KOH

... with acids, e. g. HNO3

ECOFLUXIFS 1000 F

� Flangeless version� Rugged measuring tube with

stainless steel reinforcedTeflon® PFA liner

� Particularly economical� Wide field of application

pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)85liter/h - 760m3/h0.3 - 3 360US Gal/minDN10 - 150 and 3/8” - 6”up to 16bar/230psig– 25 to + 120°C/– 13 to + 248°FIP 67, equivalent to NEMA 4/4X

Teflon® PFA

Hastelloy C4

nopending Div 2**no

IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F

environmental engineering water andsewage, agriculture, batching of fertilizers and liquids feeds

very good

NaOH up to 70% at 20°C/68°F

HNO3 up to 65% at 20°C/68°F

(limited by electrode material)

(limited by electrode material)

AQUAFLUXF

� Flanged connections� Steel housing� Liner of Polypropylene, NSF-

approved Polyurethane liner and KTW approved hard rubber quality

� Particularly economical

pulsed DC field≥ 20µS/cm85liter/h - 305 000m3/h0.3 - 1 400 000US Gal/minDN10 - 3000 and 3/8” - 120”up to 40bar/580psig– 5 to + 90°C/+ 23 to + 194°FIP 67, equivalent to NEMA 6

≥ DN25 / ≥ 1” hard rubber≤ DN20 / ≤ 3/4” Teflon® PTFEHastelloy C4

nonono

IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F

environmental engineering,water and sewage

higher than required for the applications in question

NaOH up to 50% at 20°C/68°F

HNO3 up to 5% at 20°C/68°F

ALTOFLUXIFS 4000 FIFS 4005 F

� Flanged connections� Steel housing� Teflon® PFA liner, reinforced with

stainless steel mesh, for highchemical, vacuum and abrasionresistance

� IFS4000F for largelyhomogeneous liquids,slurries, pastes

� IFS 4005 F for liquids with highsolids content

pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)85 liter/h - 305 000 m3/h0.3 - 1 400 000 US Gal/minDN 10 - 3000 and 3/8” - 120”up to 40bar/580psig– 60 to + 180°C/– 76 to + 356°FIP 67, equivalent to NEMA 6

Teflon® PFA, Teflon® PTFE,ETFE (Tefzel)Hastelloy C4, platinum, titanium,stainless steel 1.4571/316 Ti.

EEx eq ib IIC T3 . . . T6Class I, II, III, Div 1, 2no

IFS 4000 F: IFC 010 F / IFC 020 F, EIFC 090 F IFC 110 FIFS 4005 F: SC 150 F

the ”workhorse” for water, sewage andwaste water, chemicals, paper,cellulose, ore dressing

dependent on liner material, very highwith Teflon® PFA

all concentrations with Teflon® PFA orPTFE linersall concentrations with Teflon® PFA or PTFE liners

(select materials for grounding ringsand gaskets for process compatibility)

12 Background 3.1

Primary heads of electromagnetic flowmeters

Backgro

und

Wate

r

Wastew

ater

Abrasive

,co

rrosive

andho

t produ

cts

Non-contact

measurem

entκ

≥0.05

µS/cm

Food,

Beve

rage,

Pharm

aceutical

High

Pre

ssure

and special

conne

ctions

Integral

and Rem

ote

Rem

ote

Calibration

/M

easuringP

rinciple

Sizing /

instal-latio

n guide

sO

rderingguide

Signal co

nverte

r

PROFIFLUXIFS 5000 K

� Flangeless (sandwich) design� Stainless steel housing� The only precision flowmeter

with flow profile-optimizingmeasuring tube

� Influence on measuring accuracy from temperature,viscosity, pressure and flow profile is extremely slight

pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)6liter/h - 340m3/h0.02 - 1 500US Gal/minDN 2.5 - 100 and 1/10” - 4”up to 40bar/580psig– 60 to + 180°C/– 76 to + 356°FIP 67, equivalent to NEMA 6

fused aluminium oxide, 99.7% Al2O3

Cermet, platinum

EEx me ib IIC T3 . . . T6Class I, II, III, Div 2**yes

IFS 5000 F: IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F

all applications requiringextremely high measuring stability under arduous operating conditions.

extremely high

NaOH up to 50% at 50°C/122°F

HNO3 up to 99% at 90°C/194°F, HF(hydrofluoric acid), all concentr. up to50°C/122°F

(select materials for grounding ringsand gaskets for process compatibility)

ALTOFLUXIFS 2000 FIFS 2005 F

� Flanged connections� Steel housing � Measuring tube made of Al2O3

almost as hard as diamonds� High measurement and long-term

stability, even with highly abrasiveproducts

� IFS 2000 F: for largely homogeneousliquids, slurries, pastes

� IFS 2005 F: for liquids with high(and coarse-grained) solids content

pulsed DC field≥ 5µS/cm (water ≥ 20µS/cm)19liter/h - 2100m3/h84 - 930US Gal/minDN 150 - 250 and 6” - 10”up to 16bar/230 psig– 60 to + 120°C/– 76 to + 248°FIP 65, equivalent to NEMA 4/4X

fused aluminium oxide, 99.7 % Al2O3

Hastelloy C4, platinumstainless steel 1.4571/316 Ti

noClass I, II, III, Div. 2no

IFS 2000 F: IFC 020 F, EIFC 090 FIFC 110 FIFS 2005 F: SC 150 F

aluminium, ore mining,heat measurement

extremely high

NaOH up to 50% at 50°C/122°F

HNO3 up to 99 % at 90°C/194°F

(select materials for grounding rings,electrodes and gaskets for processcompatibility)

VARIFLUXIFS 6000 F

� Various sanitary/flanged connec-tions, stainless steel housing

� FDA approved Teflon® PFA liner, vac-uum resistant, CIP and SIP cleaning facilitated by uniquemetal reinforcement of the PFA

� Largest selection of sanitary con-nections

pulsed DC field ≥ 5µS/cm (water ≥ 20µS/cm)6 liter/h - 220m3/h0.02 - 950US Gal/minDN 2.5 - 80 and 1/10” - 3”up to 40bar/580psig – 60 to + 180°C/– 76 to + 356°FIP 67, equivalent to NEMA 6

Teflon®-PFAFDA approvedHastelloy C4, platinum, titanium,stainless steel 1.4571/316 Ti

EEx me ib IIC T3 . . . T6*Class I, II, III, Div. 1, 2*Dairy and Research CenterWeihenstephan, A3

IFC 010 F / IFC 020 F, EIFC 090 FIFC 110 F

food and beverage, pharmaceutical,cosmetics, chemical

high

all concentrations

all concentrations

(select materials for connections andelectrodes for process compatibility)

TIDAFLUXIFS 4000 PF

� Designed for partially filled pipelines� Excellent measuring accuracy, also

for low levels, through the integratedcapacitive level measuring system

� Saves installation and maintenanceof sluice underpasses

pulsed DC field≥ 50µS/cm35liter/h - 100 000m3/h0.2 - 500 000US Gal/minDN200 - 1800 and 8” - 24”up to 10bar/150psig– 5 to + 60°C/+ 23 to + 140°FIP 67, equivalent to NEMA 6

Irathan, 12mm/0.47”

Hastelloy C4

Ex N, Zone 2 (option) in preparationno

IFC 110 PF

sewage in partially filled

pipelines

very high

NaOH up to 10% at 30°C/86°F

HNO3 up to 5% at 20°C/68°F

13Background 3.1

14 Background 3.1

Characterization

Application

Special features

Magnetic field excitation

Full-scale range

Outputs CurrentPulse

Status

Control input

Interfaces (option)

Power supply

Power consumption

Error limits overall system

Standard equipment

Other versionsHazardous-duty versionEuropean StandardFM (Factory Mutual)

For custody transfer

IFC 010 K IFC 020 KIFC 010 F IFC 020 F

IFC 020 E

� IFC 010 K/IFC 020 K of integral design� IFC 010 F/IFC 020 F in field housing� Signal processing by microprocessor,

good dynamic response. Basic version with dis-play/totalizing and control unit with plain-textoperator prompting,all functions/data can be set.IFC 020: display/totalizing, HART®/RS 485 interface, higher field current,IFC 020 E 19” plug-in version.

For liquids, pastes, sludges and slurries with up to 3%solids content, IFC 020 for pulsating flows with up toapprox. 200 pump lifts/min, and batching processes.

Identical electronic module for remote-system andcompact flowmeters = simplified stocking of spares.Modular electronic unit easily upgradable, easilyadaptable to meet additional requirementsBidirectional pulsed DC field.

0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20 mA0 – 10 pulses/s (scalable), 0 – 100 Hz0 – 1000 Hz for full-scale rangeBinary output, e.g. for flow direction error indication

HART®, smart, RS 485; Profibus in preparation

24, 48, 100 – 240V AC, 48 – 63Hz and 24 V DC

5VA / 4W

± 0.5% of measured value

Low-flow cutoffForward/reverse flow measurementLimit contactTest function for converter and receiverinstrumentsGalvanic isolationOvervoltage protector (supply powerand all outputs)

––

IFC 090 KIFC 090 F

� IFC 090 K of integral design� IFC 090 F in field housing� Signal processing by microprocessor,

very good dynamic response.Basic version with display/totalizing and controlunit with clear-text operator prompting, all func-tions/data can be set (also with magnetic sen-sors without opening the housing)

Liquids, pastes, sludges and slurries with solids content up to 5%, also for pulsating flows up toapprox. 200 pump lifts/min, and batching processes

Outstanding repeatability and dynamic responsethrough higher field frequency and field current.Modular electronic unit, easily upgradable, easilyadaptable to meet additional requirements.Bidirectional pulsed DC field.

0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20 mA, etc.0 – 1000 pulses/s (scalable) for full-scale range

Binary output, e.g. for direction of flow error indication, range selection

Binary outputs switch-selectable to the control input, e.g.set outputs and totalizer to zero, external range change, etc.HART®, smart, RS 485; Profibus; Fieldbus

24, 48, 100 – 240V AC, 48 – 63Hz and 24V DC

10VA / 8W

± 0.3% of measured value

Low-flow cutoff, Forward/reverse flow measurement,Automatic range change Limit contacts, External rangeselector, External totalizer resetTest function for converter and receiver instruments,Galvanic isolationOvervoltage protector (supply power and all inputsand outputs)

in preparationin preparation

in preparation

Signal converters for electromagnetic flowmeters

Backgro

und

Wate

r

Wastew

ater

Abrasive

,co

rrosive

andho

t produ

cts

Non-contact

measurem

entκ

≥0.05

µS/cm

Food,

Beve

rage,

Pharm

aceutical

High

Pre

ssure

and special

conne

ctions

Integral

and Rem

ote

Rem

ote

Calibration

/M

easuringP

rinciple

Sizing /

instal-latio

n guide

sO

rderingguide

Signal co

nverte

r

15Background 3.1

IFC 110 F IFC 110 PF

� Signal converter in field housing� Signal processing by microprocessor,

outstanding interference rejection,very good dynamic response

� Basic version without display orcontrol unit

� Option: display/totalizing and controlunit with plain-text operator prompting,all functions/data can be set.

� IFC 110 PF for TIDALFLUX IFS 4000 PF

Liquids, pastes, sludges and slurries with solids con-tents up to 5%, also for pulsating flows up to approx.200 pump lifts/min, and batching processes

3 status indication outputs and 2 control inputs alloweasy, flexible system integration. Modular electronicunit, easily upgradable, with unassigned slots for add-on boardBidirectional pulsed DC field, field.

0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20mA, etc.0 – 10 000 pulses/s (scalable)

4 binary outputs, e.g. for flow direction,error indication, automatic range change

2, e.g. totalizer reset, hold outputs, set outputs tozero, testHART®, smart, RS 485; Profibus in preparation

85 – 264V AC, 48 – 63 Hz and 24V DC/AC

15VA / 15W

± 0.3% of measured value (option: 0.2%)

Low-flow cutoff, Forward/reverse flow measurement,Automatic range change, Limit contacts, Externalrange selection, External totalizer reset, Function testof converter and receiver instruments,Galvanic isolation Overvoltage protector (supply powerand all inputs and outputs)

in preparationin preparation

in preparation

SC 150 F

� Signal converter in field housing for wall mounting� Signal processing by microprocessor,

outstanding interference rejection, through highfield frequency and field current, very good measuring stability despite high frequency.

� Option: magnetic sensors for setting all data without opening the housing

Liquids, pastes, slurries, sludges with solids contentsin excess of 30%, e.g. paper and pulp industry,hydraulic conveyance (ore dressing), dredging industry

Heavy-duty electronic module, Excellent measuringsignals, Outstanding repeatability through high fieldcurrent,Designed for toughest process conditionsBidirectional, pulsed high-power DC field.

0.3 – 12m/s, 1 – 40ft/s configurable in user-definable flow units0/4 – 20mA, etc.0 – 10 000 pulses/s (scalable)

Binary output, e.g. for direction of flow,error indication

RS 485

100 – 240V AC, 48 – 63Hz

approx. 50VA

± 0.4% of measured value

Low-flow cutoff, Forward/reverse flow measurementAutomatic range change, Limit contacts,Galvanic isolation

––

Characterization

Application

Special features

Magnetic field excitation

Full-scale range

Outputs CurrentPulse

Status

Control input

Interfaces (option)

Power supply

Power consumption

Error limits overall system

Standard equipment

Other versionsHazardous-duty versionEuropean StandardFM (Factory Mutual)

For custody transfer


Top Related