ENGINEERED FILTRATION ULTIDRI® OIL CONDITIONING SYSTEMS
ULTIDRI® OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION FOR LUBRICATION AND HYDRAULIC SYSTEMS
1
THE IMPORTANCE OF OIL CONDITIONING“Over 70% of equipment failures can be attributed to contamination*.” Oil conditioning is vital for achieving cleanliness goals. The ULTIDRI® System improves the oil condition, minimizing equipment wear, maintenance expenses, and costly downtime.
Lubrication systems rely on a layer of oil to separate moving surfaces. Water contamination reduces lubricity and causes the formation of solids within this layer due to the formation of rust, corrosion, varnish deposits, or the breakdown of oils due to oxidation, additive depletion, and changes in viscosity. These particles act as an abrasive and, as a result, there is a high probability for the life of the bearings and components to be shortened.
High levels of moisture in oil can also lead to oxidation and hydrolysis. This degradation can cause changes in oil viscosity, varnish and sediment, additive depletion, and rust. The ULTIDRI® technology makes extremely low moisture levels attainable – well below the oil saturation limit in most cases. And, because the system runs continuously, oil is constantly maintained at low moisture levels.
EASY TO INSTALL, OPERATE, AND MAINTAINConveniently sized and easy to maintain, the ULTIDRI® System is well suited for applications where conventional vacuum purifiers may be too labor intensive or where the use of highly skilled operators is not desired. These self-contained units are easy to install, simple to operate, and require only minimal, periodic operator intervention.
MODULAR, SCALABLE, AND PORTABLE OPTIONSProviding robust protection in a compact, self-contained package, the Portable ULTIDRI® Models are popular in the field. This is attributed to their small footprint and versatility. A unit may be dedicated to a single reservoir for continuous conditioning or utilized across multiple reservoirs - for the ultimate in usage flexibility.
When volume, design, and flexibility are essential, this technology brings a whole new concept to the industry - called scalable modularity. This means that while ULTIDRI® System technology can be used for large and expensive equipment, it can also be scaled down in size for virtually any flow rate at a cost-effective price. Scalable modularity makes ULTIDRI® System a practical and effective solution for virtually any application or reservoir size.
The ULTIDRI® Oil Conditioning System combines filtration and membrane technologies to thoroughly remove solid contaminants, as well as, free, emulsified, and dissolved water from a wide variety of industrial and portable lubrication and hydraulic systems.
*Thibault, Ray. “Part I - Oil Cleanliness: The Key To Equipment Reliability.” Maintenance Technology. Sept 2007.
ENGINEERED FILTRATION ULTIDRI® OIL CONDITIONING SYSTEMS
ULTIDRI® OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION FOR LUBRICATION AND HYDRAULIC SYSTEMS
2
PRODUCT FEATURES ‡
1
2
3
5
8
7
BACK VIEW1. QUICK CONNECT COUPLING+ for isolation of individual
contactors for easy change out2. OUTLET COALESCER+ to prevents oil bypass3. Positive Displacement PUMP for a consistent flow rate
MOISTURE SENSOR (OPTIONAL, NOT SHOWN)+ for real-time indication of moisture level in oil
461
‡ Onboard compressor on portable model only¥ In the portable version of the ULTIDRI® System, the control panel has on/off functionality only+Features available on modular configurations only
3
FRONT VIEW1. CONTROL PANEL¥ with protective auto-shutdown2. BEACON LIGHT+
with system run status and fault indicator
3. PREFILTER+ for particulate removal4. DP SWITCH+ signals filter change-out conditions5. DURIONTM MEMBRANE CONTACTOR for oil dehydration
down to <50ppm6. INLET AIR COALESCER with visual indicator and auto-
float drain7. MEMBRANE AIR DRYER for oil dehydration8. Adjustable PRESSURE REGULATOR to conserve air 9. FORKLIFT AND PALLET-JACK ACCESSIBLE
MOUNTING FRAME for easy transport
9
2
ENGINEERED FILTRATION ULTIDRI® OIL CONDITIONING SYSTEMS
ULTIDRI® OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION FOR LUBRICATION AND HYDRAULIC SYSTEMS
3
HOW IT WORKS
The ULTIDRI® System utilizes the mass transfer capacity of completely dry air (<1% humidity) to effectively remove free, emulsified, and dissolved water – in most cases below the moisture saturation limit.
KEY BENEFITS
• Helps to minimize equipment wear and improve system reliability
• Helps to prolong the time between oil changes• Easy to install, simple to operate• Removes free, emulsified, and dissolved water, as well
as particulates, from petroleum-based and synthetic oils (down to 50 ppm or less)
• Water exhausts in vapor form; no liquid waste steam to dispose of
• Operates at normal oil temperature; no heat or post process cooling required
DURIONTM MEMBRANE
DURIONTM Membrane Technology is the future of moisture transfer. Strong and effective, this technologically advanced materialis ideal for lubrication and hydraulic fluid treatment. The durability of the DURIONTM membrane is attributed to its high chemical resistance and mechanical strength.
1
2
3Oil flows through the ULTIDRI® System where the patented hollow fiber contactor distributes the oil into relatively thin films to encourage dehydration
Water diffuses from the oil through the DURIONTM membrane into the dry air and is exhausted into the atmosphere in vapor form
Clean dry oil exits the ULTIDRI® contactor
10000
100000
1000000
10000000
10
100
1000
10000
June 2 June 9 June 16
Parti
cles
/100
ml
Wat
er (p
pm)
Date
Main Hydraulic Reservoir
Water Content by Karl Fischer Titration MethodStable Water/Oil Emulsion
Water SaturationParticles (4-6 micron)
System Install
ENGINEERED FILTRATION ULTIDRI® OIL CONDITIONING SYSTEMS
ULTIDRI® OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION FOR LUBRICATION AND HYDRAULIC SYSTEMS
4
PORTABLE ULTIDRI® OIL CONDITIONING SYSTEMS
LPS 11060 CNR
ULTIDRI SUPPLY POWER COMPRESSED AIR SOURCE11060 - 115 VAC / 60 Hz / 1 PH23050 - 230 VAC / 50 Hz / 1 PH
CNR - On-board Oil-less CompressorNNR - Supplied by Customer
To create your ordering part number, use the part number configurator below.
EXAMPLE: LPS11060CNRPortable ULTIDRI (LPS), 115 VAC / 60 Hz / 1 PH (11060), On-board Oil-less Compressor (CNR).
Portable
21.2”(539 mm)
9.6”(244 mm)
49.5”(1257 mm)
TOP VIEW
FRONT VIEW BACK VIEW
ENGINEERED FILTRATION ULTIDRI® OIL CONDITIONING SYSTEMS
ULTIDRI® OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION FOR LUBRICATION AND HYDRAULIC SYSTEMS
5
To create your ordering part number, use the part number configurator below.
EXAMPLE: LDSU401N06A040PUltiDri (LDSU4), 01 Single Contactor (1), NPT (N), 06 - 3/4” Pipe (06), 115VAC/60Hz/1PH Supply Power (A), 040- 4.0 GPM / 15.1 LPM (040), Moisture Probe and Meter Kit (P).
MODULAR ULTIDRI® OIL CONDITIONING SYSTEMS
LDSU4 01 N 06 A 040 P
ULTIDRI NUMBER OF MODULES
INLET /OUTLET PORT STYLE
PORT SIZE SUPPLY POWER PUMP FLOW RATE
SPECIAL OPTIONS
01 - Single Contactor02 - Dual Contactor03 - Triple Contactor07 - Seven Contactor
N - NPT 06 - 3/4” Pipe08 - 1”
60 Hz SystemsA - 115VAC / 60Hz / 1PHB - 230VAC / 60Hz / 1PHC - 230VAC / 60Hz / 3PHD - 380VAC / 60Hz / 3PHE - 460VAC / 60Hz / 3PHF - 575VAC / 60Hz / 3PH
60 Hz Systems 1750 RPM
020 - 2.0 GPM / 7.6 LPM040 - 4.0 GPM / 15.1 LPM056 - 5.6 GPM / 21.2 LPM076 - 7.6 GPM / 28.8 LPM112 - 11.2 GPM / 42.4 LPM160 - 16.0 GPM / 61.0 LPM
Moisture Probe and Meter Kit
50 Hz SystemsM -115VAC / 50Hz / 1PHN - 230VAC / 50Hz / 1PHP - 230VAC / 50Hz / 3PHQ - 380VAC / 50Hz / 3PHR - 415VAC / 50Hz / 3PHS - 460VAC / 50Hz / 3PH
50 Hz Systems 1450 RPM1.7 GPM / 6.3 LPM3.3 GPM / 12.5 LPM4.6 GPM / 17.6 LPM6.3 GPM / 23.8 LPM9.3 GPM / 35.1 LPM13.0 GPM / 50.0 LPM
Custom configurations available. Please contact your sales representative for assistance.
ENGINEERED FILTRATION ULTIDRI® OIL CONDITIONING SYSTEMS
ULTIDRI® OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION FOR LUBRICATION AND HYDRAULIC SYSTEMS
6
41.0”(1041 mm)
53.7”(1364 mm)
MODULAR ULTIDRI® OIL CONDITIONING SYSTEMSLDSU401 - SINGLE CONTACTOR
MODULAR ULTIDRI® OIL CONDITIONING SYSTEMSLDSU402 - DUAL CONTACTOR
TOP VIEW FRONT VIEW BACK VIEW
TOP VIEW FRONT VIEW BACK VIEW
ENGINEERED FILTRATION ULTIDRI® OIL CONDITIONING SYSTEMS
ULTIDRI® OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION FOR LUBRICATION AND HYDRAULIC SYSTEMS
7
53.7”(1364 mm)
44.0”(1118 mm)
72.0”(1829 mm)
34.0”(864 mm)
53.7”(1364 mm)
TOP VIEW FRONT VIEW BACK VIEW
TOP VIEW FRONT VIEW
MODULAR ULTIDRI® OIL CONDITIONING SYSTEMSLDSU403 - TRIPLE CONTACTOR
MODULAR ULTIDRI® OIL CONDITIONING SYSTEMSLDSU407 - SEVEN CONTACTOR
1 Application Specific Customization - ASC is an interactive process where a team of our research and development specialists work with key customer personnel to develop a customized filtration or separation solution specifically designed to meet their device requirements.Application Specific Customization - ASC is an interactive process where a team of our research and development specialists work with key customer personnel to develop a customized filtration or Application Specific Customization - ASC is an interactive process where a team of our research and development specialists work with key customer personnel to develop a customized filtration or Application Specific Customization - ASC is an interactive process where a team of our research and development specialists work with key customer personnel to develop a customized filtration or Application Specific Customization - ASC is an interactive process where a team of our research and development specialists work with key customer personnel to develop a customized filtration or
ULTIDRI®OIL CONDITIONING SYSTEMSMODULAR • SCALABLE • PORTABLEOIL DEHYDRATION AND FILTRATION
For more information on Pentair Engineered Filtration, please contact us at [email protected].
ENGINEERED FILTRATION1350 HAMMOND RD., ST. PAUL, MN 55110, USA. +651.653.2000 MAIN, +651.653.2230 FAX, [email protected].
All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners.Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
© 2014 Pentair, Inc. All Rights Reserved. TBU01_LTRE2014
FOR LUBRICATION AND HYDRAULIC SYSTEMS
SPECIFICATIONS*
PORTABLE SERIES MODULAR SERIESCONFIGURATIONS Single Contactor Single, Dual, Triple, or Seven Contactors
Contactor Description Series 34 14” Contactor (356 mm) Series 408 18” Contactor (457 mm)
MATERIALS OF CONSTRUCTIONPre-filter Housing Anodized Aluminum Epoxy Painted SteelDehydration Contactors Aluminum Anodized AluminumPump Cast Iron & Steel Cast Iron & SteelSeals Buna-N Buna-NHoses - Tube, Cover, Couplings Buna-N, Neoprene, Plated Steel Buna-N, Neoprene, Plated Steel
Plumbing Fittings Brass & Plated Steel Brass & Plated SteelCONNECTIONSOil Inlet /Outlet 1/2” NPT / 1/2" NPT 3/4” to 1” NPT / 3/4” to 1” NPTAir Inlet/Outlet 1/4" NPT / 1/4” NPT 3/8” NPT / 1/2” to 3/4” NPT DESIGN RATINGSMaximum Operating Pressure 150 psig (10.3 barg) 150 psig (10.3 barg)Recommended Operating Pressure <75 psig (5.2 barg) <75 psig (5.2 barg)Maximum Operating Temperature 150 ºF (66 ºC) 140 °F (60 ºC)Minimum Operating Temperature 32 °F (0 ºC) 32 °F (0 ºC) System Flow Rate 0.5 gpm @ 60 Hz (1.9 lpm @ 60 Hz) 2 to 16 gpm @ 60 Hz (7.6 to 61 lpm @ 60 Hz)Air Required Approx. 0.7 scfm @ 50 psig (19.8 slpm @ 3.4 barg) for
unit without on-board compressorApprox. 4.5 to 32 scfm @ 100 psig (127.4 to 906.1 slpm @ 6.9 barg) minimum supply pressure of 80 psig (5.5 barg)
Sweep Air Dew Point -20 ºF (-29 ºC), based on 50 psig (3.4 barg) supply pressure and 100 ºF (37.8 ºC) inlet pressure dew point.
-40 ºF (-40 ºC), based on 80 psig (5.5barg) supply pressure and 100 ºF (37.8 ºC) inlet pressure dew point
System Prefiltration Rating 3µm 3µm
*Please contact Pentair to verify your configuration or to help define an ASC1 that meets your specific needs.