![Page 1: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/1.jpg)
Field Sampling and Your Bottom Line
![Page 2: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/2.jpg)
Operating Cost Reductions
Increase in operations moving to self sampling Things to be aware of:
•Sample containers •Field H2S determination •Impact of sampling procedures
![Page 3: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/3.jpg)
The “Creative” Sample Container
![Page 4: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/4.jpg)
Field H2S Determination
• H2S will degrade in metal cylinders • Stain tubes and Iodine have expiry dates • Have seen wells turn sour from 0 to >1000
ppm in a matter of months
![Page 5: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/5.jpg)
Sampling Case Study
•Same sample point •Same day •Same field staff •Two different sampling techniques
•Two cylinders taken properly (P1, P2) •Two cylinders taken improperly by purging through the cylinder (I3, I4)
![Page 6: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/6.jpg)
Proper Sampling Results
![Page 7: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/7.jpg)
Improper Sampling Results
![Page 8: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/8.jpg)
Compositional Summary
0.0000
0.1000
0.2000
0.3000
0.4000
0.5000
0.6000
0.7000
H2 He N2 CO2 H2S C1 C2 C3 iC4 nC4 iC5 nC5 C6 C7+
Correct 1
Incorrect 1
Correct 2
Incorrect 2
![Page 9: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/9.jpg)
Gas Properties
P1 P2 I3 I4 Heating Value 52.40 52.55 55.62 53.75 Gas Compressibility 0.9925 0.9925 0.9900 0.9916 Relative Density 0.882 0.883 0.934 0.900
1% RD exemption is affected by sampling in this case study
![Page 10: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/10.jpg)
Historical Data
![Page 11: Field Sampling and Your Bottom Line · 2018-02-28 · Analysis and associated calcinations are based on GPA 2261. GPA 2286, GPA 2145. AGA and TP-17. PROPER SAMPLING PROCEDURE; FIELD](https://reader034.vdocuments.net/reader034/viewer/2022042203/5ea44534272432627b4cc4e7/html5/thumbnails/11.jpg)
Thank You