Transcript
Page 1: Field To Finish Using FME

CONNECT. TRANSFORM. AUTOMATE.

Field To Finish Chad Kimble, Senior GIS Analyst Jean-Paul Stafford, Solutions Architect Eric Deroche, Director of Office And Field Technology

Page 2: Field To Finish Using FME

Field To Finish

!  FME process to convert the exported .CSV file to a .DWG file with all point data mapped to attributed blocks and line features.

!  Data QA/QC and manipulation into centralized data store.

!  Data extraction from centralized data store.

CONNECT. TRANSFORM. AUTOMATE.

Page 3: Field To Finish Using FME

Past Field To Finish Process

Field Data Collected

Data Imported Into AutoCAD using various

tools

Data QA\QC in AutoCAD and drawing stored in a

project folder

Page 4: Field To Finish Using FME

Problems

!  No company wide standard schema for data collected

!  No auto generation of drawings to speed up data collected in the field to client(s)

!  No centralized data store for current and archive retrieval

!  No data transformations for reoccurring processes.

Page 5: Field To Finish Using FME

Solution

Page 6: Field To Finish Using FME

Data Standards

!  Centralized data standards for data collected in the field

!  Schema standardization of spatial data store !  QA\QC process for all data collected !  Standard symbology for all data types !  Standard templates for all drawings generated

Page 7: Field To Finish Using FME

CSV(PNEZD) TO DWG

Page 8: Field To Finish Using FME

CSV(PNEZD) TO DWG

!  Iterates through each individual feature code and routes accordingly to the correct feature type.

!  Data QA\QC is automated and validation log files generated.

!  DWG output with standardized template which includes populated point attributes and object data

Page 9: Field To Finish Using FME

CSV(PNEZD) TO DWG OUTPUT

Page 10: Field To Finish Using FME

DWG To Spatial Data Store

!  Iterates through each individual feature extracting object data then stored in spatial data store according to defined schema

!  Data QA\QC is automated and validation log files generated

!  Data is centralized to be viewed or edited by internal users for final adjustments

Page 11: Field To Finish Using FME

Data Extraction Process

Page 12: Field To Finish Using FME

Data Extraction Process

Page 13: Field To Finish Using FME

Data Extraction Process

!  Users can extract data via a viewer or from FME Server

!  Users can specify output data format from multiple listings (currently DWG,SHP,SDF,KML).

!  Users can specify output data projection !  Users can select whether polylines or polygons

should be clipped to a certain Area Of Extent

Page 14: Field To Finish Using FME

Thank You!

!  Questions?

!  For more information: !  Chad Kimble, [email protected] !  Jean-Paul Stafford, [email protected] !  Eric Deroche, [email protected]

CONNECT. TRANSFORM. AUTOMATE.


Top Related