Ultrasonic meter : 12 ”Operating flow rate : 90 % QmaxBais Error : 0.5 %$2500/day or $1000000/annumLoss can be avoided by calibration
Cost due to Error of 0.25% is about Rs120 Crore/annum
![Page 3: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/3.jpg)
Initial calibration by manufacturersFor checking of accuracy by the user.After major repairs.Under Statutory ObligationsLegal DisputesTo improve accuracy
![Page 4: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/4.jpg)
Orifice meters Large volumeTurbine meters Large volumeUltrasonic gas meter Large volumeCritical flow Venturi Large volumeCoriolis mass meters CNG
![Page 5: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/5.jpg)
Cheap, commonly used metersReasonable performance, good reliabilityModerate costPressure difference proportional to flow rateSharp square edged cylindrical throat
![Page 6: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/6.jpg)
![Page 7: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/7.jpg)
![Page 8: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/8.jpg)
Flange, corner, D and D/2, pipe tapsFlange tap for Natural gasDiameter ratios ,0.1 – 0.75Orifice diameters > 0.45”Cd depends on , ReD and tap
![Page 9: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/9.jpg)
![Page 10: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/10.jpg)
Depends on Reynolds Number, diameter ratioFor Cd, 0.4 – 1%Expansibility factorGeometrical measurementsFlow parametersOverall uncertainty 1 – 2%
![Page 11: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/11.jpg)
Cheap, good performance and reliabilityModerate cost with Simple metrology Conform to AGA-3 standard No need for wet plate calibrationLow flow range (1:3 Typical)Susceptible to erosion, damage Cost effective metering solutionOverall uncertainty 1 – 2% (0.4-0.6% in Cd)
![Page 12: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/12.jpg)
Flowing gas imparts force on rotorActual rotational speed depend
passage way size shape/ rotor designload due to internal mechanical friction fluid drag external loading gas density
maximum velocity 50 m/s
![Page 13: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/13.jpg)
PassageAnnularInlet
BodyElectrical Readout
Outlet
Houseing andTail Cone
Mechanism
421 3 5
Mechanical or
6connectionEnd
Electronic Pickup
Nose cone
Rotor
![Page 14: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/14.jpg)
1.0% (Qi > Qt)
Maximum peak-to-peak error
1.251.50
0.500.751.00
0.000.25
0.500.25
1.251.00
1.751.50
Percent error
0.75
tmin Q < 0 .2 QQ iFlow rate (Q )
Repeatability +/-0.2%
1.751% for 0.2 Qmax - Qmax1.5% for Qmin - 0.2 Qmax 0.35% for 0.2 Qmax - QmaxRepeatability : 0.2%Effect of swirl should be less than 1/3 of normal specifications
![Page 15: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/15.jpg)
Frequency counters - for instantaneous flow rate Integrator - for totalized flow Transmitters - for control applications Flow computers - for billing purposes
![Page 16: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/16.jpg)
The ability of the meter to duplicate a given output or performance for test runs with an identical set of flowing conditions. Under normal conditions +/-0.1% on successive short duration and +/-0.15-0.2% on day to day basis.
![Page 17: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/17.jpg)
Designed for a maximum flow rate Fixed by rotor speed Normal pressure loss.Same irrespective of operating pressure.
Lowest flow rate at which the meter will operate within specified accuracy limits (+/-1%).Depends on magnitude of non-fluid drag and the density Qmin -0.5
![Page 18: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/18.jpg)
![Page 19: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/19.jpg)
SWIRL EFFECT Rotor designed for axial flow at rotor inlet Swirl affects the rotor speed swirl increases or decreases the speed depending on
the direction of swirl. Tests at 0.25, 0.4, Qmax with atmospheric air. Error shifts 1/3 of maximum permissible error.
![Page 20: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/20.jpg)
![Page 21: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/21.jpg)
Low level perturbation tests Perturbation unit with double elbow out of plane. Resembles perturbations by bends, tees,
convergent and divergent sections.High level perturbation tests
Perturbation unit with double elbow out of plane with half area plate in between
Resembles perturbations by regulators or throttling devices.
![Page 22: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/22.jpg)
![Page 23: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/23.jpg)
![Page 24: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/24.jpg)
Recommended Installation
![Page 25: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/25.jpg)
Less sensitive to upstream disturbances Output digital, linear, electronics Compact with moderate head lossMore expensive (larger sizes)Gradual wear and fouling of surfacesPeriodical recalibrationPerformance of smaller turbine meters
![Page 26: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/26.jpg)
AGA Report No.9 Multipath ultrasonic meters for custody transfer of natural gasDutch Ministry of Economic Affairs PTB, Germany Uncertainty in line with Turbine meterProduction facilities, transmission pipelinesStorage facilities, distribution systems
![Page 27: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/27.jpg)
![Page 28: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/28.jpg)
![Page 29: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/29.jpg)
![Page 30: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/30.jpg)
![Page 31: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/31.jpg)
![Page 32: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/32.jpg)
Bi directional capabilityNo additional pressure dropMeasurement of pulsating flowsWide rangeabilityNo moving partsLess weight and spaceNo drift due to no wear offInsensitive to asymmetrical , pulsating, rotating flows and wet/untreated gas
![Page 33: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/33.jpg)
18 Path USFM for liquids : 0.15 %
![Page 34: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/34.jpg)
Measurement of spool diameterAcoustic path L and XDry calibration accuracy 1% or better Performance depends on signal processing / path configurations Measurement of delays for electronics / transducersMeasurement of sound velocity in pressurized test all.
![Page 35: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/35.jpg)
L2x(tu - tD) Flow Velocity, v = ------------ 2 x tu x tD Lx(tu + tD) Sound Velocity, v = ------------ 2 x tu x tD L : Straight length of acoustic path X : Axial distance tu, tD : Transit times
![Page 36: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/36.jpg)
Precise Geometry of body and transducer locationInherent integration techniquesQuality of profile, pulsation, gas uniformityElectronic clock stabilityConsistent detection of pulseCompensation for signal delaysParallel paths Direct or reflected paths along 2 or more tilted chordsWeighting factors for each path
ACCURACY
![Page 37: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/37.jpg)
ACCURACY
Average ID, Acoustic Path Length, Axial distance between transducer pairAverage ID from 12 measurementsVertical(1), Horizontal(1) and 45o from vertical (2)Near upstream, near downstream and half way between transducerCalculation by trigonometryBody temperature at the time of measurementCorrection to 20oC and to 0.01 mm
![Page 38: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/38.jpg)
Zero Test Meter purged of air with pure test gas or gas mixture Properties of test gas must be knownSound velocities for each acoustic path recorded for 30sMean and standard deviationAdjustments for compliance to performanceTheoretical speed of sound from composition, pressure and temperatureDocument all relevant parametersZero flow offset factor in +/- m/s
![Page 39: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/39.jpg)
Zero Test
![Page 40: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/40.jpg)
Flow Test
qmin, 0.1 qmax, 0.25 qmax, 0.4qmax, 0.7 qmax and qmaxAt expected average operating conditionsSpecific piping configuration and / or flow conditionerDiameters of flanges /connecting pipes to match (±1%)Traceable flow calibration facilityProperties AGA Report No.8 “Detail Characterization Method”
![Page 41: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/41.jpg)
![Page 42: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/42.jpg)
![Page 43: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/43.jpg)
Size : 1/16" up to 10"Flow Range : g/h - 10 t/mRange : 25 : 1 (Typical) and 100 : 1 in some application.Accuracy : ±0.15% - ± 0.25% R+ Zero shift error. ±0.5% R for gasesUncertainty of measurement facilities ±0.3% - ± 0.6% R
![Page 44: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/44.jpg)
![Page 45: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/45.jpg)
Repeatability : +/-0.5% (qt<qi <qmax)Max Peak to peak error : +/-1%(qt<qi <qmax)Max mean error : +/-1% (qt < qi < qmax)
1.75
1.25
0.75
0.250.00
-0.75
-0.25
-1.75
-1.25
Perc
ent
erro
r
Qmin Qt Flow Rate (Qi)
Repeatability ±1.0%
Repeatability ±0.5%
(Qi < Qt)
(Qi > Qt)
(Qi > Qt)Max Peak to Peak spread 1.0%
Qmax
![Page 46: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/46.jpg)
![Page 47: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/47.jpg)
![Page 48: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/48.jpg)
Critical velocity at the throat Mass flow rate maximum for the existing upstream conditions ISO 9300 Throat Reynolds Number 2.1 x 104 - 3.2 x 107 Relative uncertainty in Cd 0.3% - 0.2% Gas pressure and the gas temperature at upstream Pressure ratios of 0.75 - 0.95
![Page 49: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/49.jpg)
c
0.9D to 1.1D
r = 1.8d to 2.2d
Ød_ØD>4d
2.5d ±0.1d
>d _
![Page 50: Flow meters for gas measurement](https://reader036.vdocuments.net/reader036/viewer/2022081505/58719ab01a28ab044e8b599d/html5/thumbnails/50.jpg)