Fluke Clamp MetersSolutions for every need
Job functions Applications Key features Recommended Clamp
Electrical Contractor Working on panels and branch circuits•Measureloadsonabranchcircuitatapanel(includingfeedercables,
branch circuits, and neutrals) and the continuity of switches, fuses, and contacts
•Measureloadsidevoltageofabreakerorfuse•Checkifacircuitislivebeforebeginningwork
•OpenJawaccurrentmeasurementto100A•ACandDCvoltage•T5-600:CATIII600Vac/dc•T5-1000:CATIII1000Vac/dc,CATIV600Vac/dc•Continuity,resistance•Ruggedandeasytouse
T5-1000CAT III 1000 VOthers in the family: T5-600Facility Maintenance
Commercial Electrician
Commercial Electrical Contractor Verify circuit integrity and operation•Measureloadcurrent,acvoltageandcontinuityofswitches,fuses,and
contacts
Feeder Cables•Checkbalanceandloadingoffeedercables
•Measureupto400Aac•0.01Aresolutioninthe40Arangeformore
precise measurments•Compactformfactortomakemeasurmentseasily
in tight cable compartments•Measureacanddcvoltageto600V•Resistance,continuity,anddisplayholdfunctions
322CAT III 600 VOthers in the family: 321Industrial Electrical Contractor
Plant Maintenance
Electrical Contractor Working with motors and drives•Measuremotorstart-upandruncurrent•Measuretheoutputofvariablespeedmotorsanddrives
In and around the service panel•Clamparoundbusbarorconductorstomeasureloadsandlinefrequencyin
circuits and feeders
Measure ac or dc current•Measureacordcforuseinbattery-operatedsystemslikeUPSorotherdc
systems
• Inrushcurrentmodeforrepeatablemeasurement ofmotororequipmentstart-upcurrent
•Narrow,elongatedjawwithlargeopeningeasilysingles out the conductor of interest
•True-rmstomoreaccuratelymeasuretheactual current, even with distorted wave-forms caused by noisy loads
• Includeslargebacklitdisplay,frequency,acanddcvoltage, resistance, continuity, and min/max
337CAT III 600 VOthers in the family: 333, 334, 335 and 336
Commercal Electrician
Plant Maintenance
Industrial Electrician
Industrial Service Electrician Service panel, service entrance, and low voltage vaults• Intheservicepanel,clamparoundeachindividualphase.(Goodforlarge
single or parallel conductors)• Intheserviceentrance,clamparoundbusbars,upto2.5in,toverify
expected current usage•Measurecurrentinconductorsoflow-voltagevaults(1000Vorless)
Working with large loads•Verifyoperationoflargeloadservicepanels,switchgears,largecurrent
DC systems, and motors
•Upto2000Adc,1400Aaccurrentmeasurement• Largejawsuitableforsingleormultiplelarge
conductors•CatIV600Vratedformaximumapplication
versatility• Inputsfor600Vac,1000Vdc,400KΩ resistance,
and continuity• Lowpassfilter,min/max/avg,andinrushcurrent•Accuratelymeasurefrequencyofcurrentand
voltage up to 1 kHz
355CAT IV 600 V, CAT III 1000 VOthers in the family: 353
Electrical Contractor
Electric Utility Technician
Marine or Welding Electrician
Facility Maintenance Electrician
HVAC/R Service Technician Checking boilers and furnaces•Capturefluegastemperaturesandperformflamerodtesting
HVAC Motors and drives•Measurestartandrunmotorcapacitors•Troubleshootcompressorelectricalmotorfaults•Measureperformanceofvariablefrequencydrives
Testing electrical performance•Measureload-sideandsupply-sidecurrentandvoltage•Measurecurrentandvoltagephasebalanceon3phasesystems
•Measurecurrentupto600Aacandupto 200 µA dc
•Measuretrue-rmsvoltage,capacitance,resistance,and continuity
•Measurecontacttemperaturewithincluded Type-K temperature probe. (Or measure the outside temperature of a pipe with the 80PK-8 Pipe Clamp Temperature Probe (sold separately))
902 600 V CAT III
Clamp Meter selection chart
Job functions Applications Key features Recommended Clamp
Electrical Contractor Working on panels and branch circuits•Measureloadsonabranchcircuitatapanel(includingfeedercables,
branch circuits, and neutrals) and the continuity of switches, fuses, and contacts
•Measureloadsidevoltageofabreakerorfuse•Checkifacircuitislivebeforebeginningwork
•OpenJawaccurrentmeasurementto100A•ACandDCvoltage•T5-600:CATIII600Vac/dc•T5-1000:CATIII1000Vac/dc,CATIV600Vac/dc•Continuity,resistance•Ruggedandeasytouse
T5-1000CAT III 1000 VOthers in the family: T5-600Facility Maintenance
Commercial Electrician
Commercial Electrical Contractor Verify circuit integrity and operation•Measureloadcurrent,acvoltageandcontinuityofswitches,fuses,and
contacts
Feeder Cables•Checkbalanceandloadingoffeedercables
•Measureupto400Aac•0.01Aresolutioninthe40Arangeformore
precise measurments•Compactformfactortomakemeasurmentseasily
in tight cable compartments•Measureacanddcvoltageto600V•Resistance,continuity,anddisplayholdfunctions
322CAT III 600 VOthers in the family: 321Industrial Electrical Contractor
Plant Maintenance
Electrical Contractor Working with motors and drives•Measuremotorstart-upandruncurrent•Measuretheoutputofvariablespeedmotorsanddrives
In and around the service panel•Clamparoundbusbarorconductorstomeasureloadsandlinefrequencyin
circuits and feeders
Measure ac or dc current•Measureacordcforuseinbattery-operatedsystemslikeUPSorotherdc
systems
• Inrushcurrentmodeforrepeatablemeasurement ofmotororequipmentstart-upcurrent
•Narrow,elongatedjawwithlargeopeningeasilysingles out the conductor of interest
•True-rmstomoreaccuratelymeasuretheactual current, even with distorted wave-forms caused by noisy loads
• Includeslargebacklitdisplay,frequency,acanddcvoltage, resistance, continuity, and min/max
337CAT III 600 VOthers in the family: 333, 334, 335 and 336
Commercal Electrician
Plant Maintenance
Industrial Electrician
Industrial Service Electrician Service panel, service entrance, and low voltage vaults• Intheservicepanel,clamparoundeachindividualphase.(Goodforlarge
single or parallel conductors)• Intheserviceentrance,clamparoundbusbars,upto2.5in,toverify
expected current usage•Measurecurrentinconductorsoflow-voltagevaults(1000Vorless)
Working with large loads•Verifyoperationoflargeloadservicepanels,switchgears,largecurrent
DC systems, and motors
•Upto2000Adc,1400Aaccurrentmeasurement• Largejawsuitableforsingleormultiplelarge
conductors•CatIV600Vratedformaximumapplication
versatility• Inputsfor600Vac,1000Vdc,400KΩ resistance,
and continuity• Lowpassfilter,min/max/avg,andinrushcurrent•Accuratelymeasurefrequencyofcurrentand
voltage up to 1 kHz
355CAT IV 600 V, CAT III 1000 VOthers in the family: 353
Electrical Contractor
Electric Utility Technician
Marine or Welding Electrician
Facility Maintenance Electrician
HVAC/R Service Technician Checking boilers and furnaces•Capturefluegastemperaturesandperformflamerodtesting
HVAC Motors and drives•Measurestartandrunmotorcapacitors•Troubleshootcompressorelectricalmotorfaults•Measureperformanceofvariablefrequencydrives
Testing electrical performance•Measureload-sideandsupply-sidecurrentandvoltage•Measurecurrentandvoltagephasebalanceon3phasesystems
•Measurecurrentupto600Aacandupto 200 µA dc
•Measuretrue-rmsvoltage,capacitance,resistance,and continuity
•Measurecontacttemperaturewithincluded Type-K temperature probe. (Or measure the outside temperature of a pipe with the 80PK-8 Pipe Clamp Temperature Probe (sold separately))
902 600 V CAT III
Speciality clamp meters
Job functions Applications Key features Recommended Clamp
Facility Maintenance Electrician
Measuring leakage current•Checkinsulationconditionandleakageofcircuitsand
systems•Checkforleakageincircuitsandsystemsutilizingfilters
Testing insulation on live circuits•Evaluateinsulationconditiononlivecircuitsvialeakage
current measurements where disconnection is highly inconvenient
•Measurementofleakagecurrentwith3mArangeand1 µA of resolution, for accurate monitoring of insulation erosion
•Broadrangeofmeasurement,from1µAupto60A,forall installation needs
•Advancedshieldingtoensureaccurateresultswhen measuring near other conductors
•Easy-to-carry,pocket-sizedleakagecurrenttesterwithwide 40 mm (1.5 in) jaw size
360*CAT III 300 V
Hospital Electrician
Electrical Contractor
Industrial/Commercial Maintenance Electrician
Grounding and bonding resistance testing•Performgroundlooptestsinareaswhereotherground
resistancetesttechniquesarenotavailable•Testpartsofamulti-groundedsystem•Periodicallyperformquicktestsonsystemgroundsas
part of a regular preventative maintenance program
•Measurefrom0.025Ω to 1500 Ω ground loop resistance.• Largejawforclampingaroundthewidestrangeof
ground conductors or grounding bars•Measuregroundleakageandacloadcurrentsfrom
0.2 mA all the way up to 30 A•Userdefinedalarmlimitsforrapidpass/failtype
measurments
1630CAT III 300 V
Utility Technician
Electrical Contractor/ Consultant
Process Technician/ Electrician
Measuring process control signals•Measures4-20mAsignalswithoutbreakingtheloop•CheckcorrectoperationofPLCsandcontrolsystems
analog I/O
•Savestimeandmoneybyeasilymeasuring4-20mA signals
•Detatchableminiatureclampfortightlocations•Alsomeasureolder10to50mAsignalsystemswiththe
100 mA range•Backlitdisplay,spotlight,displayhold,andzeroreading
buttons
771CAT II 300 V
Automation Specialist/ Commercial Electrician
Electrical and Field Service Technician
Measuring non-linear loads•Setupandtroubleshootvariablefrequencydrivesand
UPS systems—Verify correct operation by measuring key powerqualityparameters
Harmonic measurements•Uncoverharmonicissuesthatcandamageordisrupt
criticalequipment
Troubleshooting start-up current issues •Checkstart-upcurrentwherespuriousresetsor
nuisance circuit breaker tripping occurs
Load studies•Verifyelectricalsystemcapacitybeforeaddingloads
•AC/DCcurrent:Clamp-onmeasurementofcurrentupto1400 A ac rms and 2000 A dc
•Highestsafetyrating:CATIV600Vratedforuseattheservice entrance
•Accurateinnoisyenvironments:Usinglow-passfilter,theclamp meter performs even with distorted waveforms
•Datalogging:Identifyintermittentfaultsbylogginganypowerqualityparameterforminutes,oroveramonth
•Troubleshootharmonics:Analyzeandlogharmonics digitally or graphically
• Inrushcurrent:Captureandanalyzenuisancetripping, from 3 seconds to 300 seconds
345CAT IV 600 V, CAT III 1000 V
HVAC/R Technician
Electrical Engineer
Commercial Electrician
Facility Maintenance Electrician
Electric Utility Engineer
Speciality clamp meters
Need more help choosing a clamp meter to fit your needs? Go interactive! Visit www.fluke.com/clamps and use our on-line selection guide to find the right clamp solution for you!
*Not available for sale in Canada
Job functions Applications Key features Recommended Clamp
Facility Maintenance Electrician
Measuring leakage current•Checkinsulationconditionandleakageofcircuitsand
systems•Checkforleakageincircuitsandsystemsutilizingfilters
Testing insulation on live circuits•Evaluateinsulationconditiononlivecircuitsvialeakage
current measurements where disconnection is highly inconvenient
•Measurementofleakagecurrentwith3mArangeand1 µA of resolution, for accurate monitoring of insulation erosion
•Broadrangeofmeasurement,from1µAupto60A,forall installation needs
•Advancedshieldingtoensureaccurateresultswhen measuring near other conductors
•Easy-to-carry,pocket-sizedleakagecurrenttesterwithwide 40 mm (1.5 in) jaw size
360*CAT III 300 V
Hospital Electrician
Electrical Contractor
Industrial/Commercial Maintenance Electrician
Grounding and bonding resistance testing•Performgroundlooptestsinareaswhereotherground
resistancetesttechniquesarenotavailable•Testpartsofamulti-groundedsystem•Periodicallyperformquicktestsonsystemgroundsas
part of a regular preventative maintenance program
•Measurefrom0.025Ω to 1500 Ω ground loop resistance.• Largejawforclampingaroundthewidestrangeof
ground conductors or grounding bars•Measuregroundleakageandacloadcurrentsfrom
0.2 mA all the way up to 30 A•Userdefinedalarmlimitsforrapidpass/failtype
measurments
1630CAT III 300 V
Utility Technician
Electrical Contractor/ Consultant
Process Technician/ Electrician
Measuring process control signals•Measures4-20mAsignalswithoutbreakingtheloop•CheckcorrectoperationofPLCsandcontrolsystems
analog I/O
•Savestimeandmoneybyeasilymeasuring4-20mA signals
•Detatchableminiatureclampfortightlocations•Alsomeasureolder10to50mAsignalsystemswiththe
100 mA range•Backlitdisplay,spotlight,displayhold,andzeroreading
buttons
771CAT II 300 V
Automation Specialist/ Commercial Electrician
Electrical and Field Service Technician
Measuring non-linear loads•Setupandtroubleshootvariablefrequencydrivesand
UPS systems—Verify correct operation by measuring key powerqualityparameters
Harmonic measurements•Uncoverharmonicissuesthatcandamageordisrupt
criticalequipment
Troubleshooting start-up current issues •Checkstart-upcurrentwherespuriousresetsor
nuisance circuit breaker tripping occurs
Load studies•Verifyelectricalsystemcapacitybeforeaddingloads
•AC/DCcurrent:Clamp-onmeasurementofcurrentupto1400 A ac rms and 2000 A dc
•Highestsafetyrating:CATIV600Vratedforuseattheservice entrance
•Accurateinnoisyenvironments:Usinglow-passfilter,theclamp meter performs even with distorted waveforms
•Datalogging:Identifyintermittentfaultsbylogginganypowerqualityparameterforminutes,oroveramonth
•Troubleshootharmonics:Analyzeandlogharmonics digitally or graphically
• Inrushcurrent:Captureandanalyzenuisancetripping, from 3 seconds to 300 seconds
345CAT IV 600 V, CAT III 1000 V
HVAC/R Technician
Electrical Engineer
Commercial Electrician
Facility Maintenance Electrician
Electric Utility Engineer
Clamp meters designed for the way you work.
See our full line of Fluke Accessories at www.fluke.com/accy-catalog
Commercial/industrial electrician
Residential/commercial electrician
General purpose Industrial electrician HVAC/R High end industrial, utility Leakage Process Earth ground Power quality
T5-600 T5-1000 321 322 333 334 335 336 337 902 353 355 360* 771 1630 345
MeasurementsAC current • • • • • • • • • • • • • • •AC volts • • • • • • • • • • • •Resistance • • • • • • • • • • •Continuity • • • • • • • • • • • •DC Volts • • • • • • • • • • •DC current • • • • • •True-rms • • • • • • • •Frequency • • • •Min/Max/Avg • • • • •4-20 mA (0.01 mA resolution) •Temperature •Capacitance •Earth ground loop resistance •Special featuresInrush current mode • • • • • • •Low Pass filter • • •Harmonics, power, and data logging
•
DisplayDisplay hold • • • • • • • • • • • • • • • •Backlight • • • • • • • • •Graphing display •Specifications
Jaw opening 12.9 mm (0.5 in) 12.9 mm (0.5 in) 25.4 mm (1.0 in) 25.4 mm (1.0 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 58 mm (2.3 in) 58 mm (2.3 in) 40 mm (1.5 in) 4.5mm (0.177 in) 35 mm (1.38 in) 58 mm (2.3 in)Max wire size 1/0 THHN Cable 1/0 THHN Cable 500 MCM 500 MCM 750 MCM 750 MCM 750 MCM 750 MCM or two
500 MCM750 MCM or two
500 MCM750 MCM 750 MCM or three
500 MCM750 MCM or three
500 MCM1250 MCM 6 AWG 1000 MCM 750 MCM or three
500 MCMCurrent range ac rms 0 to 100 A 0 to 100 A 0 to 400 A 0 to 400 A 0 to 400 A 0 to 600 A 0 to 600 A 0 to 600 A 0 to 999.9 A 0 to 600 A 0 to 1400 A 0 to 1400 A 0 to 60 A 0 to 35 A 0 to 1400 AAccuracy ac current (50/60 Hz) 3 %
± 3 counts3 %
± 3 counts1.8 %
± 5 counts1.8 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts1.5 %
+ 5 counts1.5 %
+ 5 counts1 %
+ 5 counts2 %
∓ 3 counts± 3 %
± 5 countsAC Response Averaging Averaging Averaging Averaging Averaging Averaging True-rms True-rms True-rms True-rms True-rms True-rms Averaging True-rms True-rmsCurrent range dc 0 to 600 A 0 to 999.9 A 0 to 200 µA 0 to 2000 A 0 to 2000 A 0 to 99.9 mA 0 to 2000 AAccuracy dc current 2 %
+ 3 counts2 %
+ 3 counts1 %
± 5 counts1.5 %
+ 5 counts1.5 %
+ 5 counts4-20 mA is 0.2 %
+ 5 counts± 1.5 %
± 5 countsVoltage range ac 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 600 V 0 to 600 V 0 to 825 V
Accuracy ac voltage 1.5 % ± 2 counts
1.5 % ± 2 counts
1.2 % + 5 counts
1.2 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % ± 5 counts
1 % + 5 counts
± 1 % ± 5 counts
Voltage range dc 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 1000 V 0 to 825 VAccuracy dc voltage 1 %
± 1 count1 %
± 1 count1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
± 5 counts1 %
+ 5 counts± 1 %
± 5 countsResistance range 0 to 1000 Ω 0 to 1000 Ω 0 to 400 Ω 0 to 400 Ω 0 to 600 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 9999 Ω 0 to 400 KΩ 0 to 1500 ΩFrequency measurement range 5 to 400 Hz 5 to 1000 Hz 5 to 1000 Hz 15 to 1000 HzUnit powerAuto off • • • • • • • • • • • • • • • •Warranty and safetyWarranty (years) 2 2 2 2 3 3 3 3 3 3 3 3 1 3 1 2
Category ratings (EN61010-1) CAT III 600 V CAT IV 600 V, CAT III 1000 V
CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V, CAT III 1000 V
CAT IV 600 V, CAT III 1000 V
CAT III 300 V Cat II 300 V CAT III 300 V CAT IV 600 V, CAT III 1000 V
*Not available for sale in Canada
Clamp meters designed for the way you work.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
Fluke. Keeping your world up and running.®
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2008 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 8/2008 3363537 B-EN-N Rev A
Modification of this document is not permitted without written permission from Fluke Corporation.
Commercial/industrial electrician
Residential/commercial electrician
General purpose Industrial electrician HVAC/R High end industrial, utility Leakage Process Earth ground Power quality
T5-600 T5-1000 321 322 333 334 335 336 337 902 353 355 360* 771 1630 345
MeasurementsAC current • • • • • • • • • • • • • • •AC volts • • • • • • • • • • • •Resistance • • • • • • • • • • •Continuity • • • • • • • • • • • •DC Volts • • • • • • • • • • •DC current • • • • • •True-rms • • • • • • • •Frequency • • • •Min/Max/Avg • • • • •4-20 mA (0.01 mA resolution) •Temperature •Capacitance •Earth ground loop resistance •Special featuresInrush current mode • • • • • • •Low Pass filter • • •Harmonics, power, and data logging
•
DisplayDisplay hold • • • • • • • • • • • • • • • •Backlight • • • • • • • • •Graphing display •Specifications
Jaw opening 12.9 mm (0.5 in) 12.9 mm (0.5 in) 25.4 mm (1.0 in) 25.4 mm (1.0 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 58 mm (2.3 in) 58 mm (2.3 in) 40 mm (1.5 in) 4.5mm (0.177 in) 35 mm (1.38 in) 58 mm (2.3 in)Max wire size 1/0 THHN Cable 1/0 THHN Cable 500 MCM 500 MCM 750 MCM 750 MCM 750 MCM 750 MCM or two
500 MCM750 MCM or two
500 MCM750 MCM 750 MCM or three
500 MCM750 MCM or three
500 MCM1250 MCM 6 AWG 1000 MCM 750 MCM or three
500 MCMCurrent range ac rms 0 to 100 A 0 to 100 A 0 to 400 A 0 to 400 A 0 to 400 A 0 to 600 A 0 to 600 A 0 to 600 A 0 to 999.9 A 0 to 600 A 0 to 1400 A 0 to 1400 A 0 to 60 A 0 to 35 A 0 to 1400 AAccuracy ac current (50/60 Hz) 3 %
± 3 counts3 %
± 3 counts1.8 %
± 5 counts1.8 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts2 %
± 5 counts1.5 %
+ 5 counts1.5 %
+ 5 counts1 %
+ 5 counts2 %
∓ 3 counts± 3 %
± 5 countsAC Response Averaging Averaging Averaging Averaging Averaging Averaging True-rms True-rms True-rms True-rms True-rms True-rms Averaging True-rms True-rmsCurrent range dc 0 to 600 A 0 to 999.9 A 0 to 200 µA 0 to 2000 A 0 to 2000 A 0 to 99.9 mA 0 to 2000 AAccuracy dc current 2 %
+ 3 counts2 %
+ 3 counts1 %
± 5 counts1.5 %
+ 5 counts1.5 %
+ 5 counts4-20 mA is 0.2 %
+ 5 counts± 1.5 %
± 5 countsVoltage range ac 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 600 V 0 to 600 V 0 to 825 V
Accuracy ac voltage 1.5 % ± 2 counts
1.5 % ± 2 counts
1.2 % + 5 counts
1.2 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % + 5 counts
1 % ± 5 counts
1 % + 5 counts
± 1 % ± 5 counts
Voltage range dc 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 1000 V 0 to 825 VAccuracy dc voltage 1 %
± 1 count1 %
± 1 count1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
+ 5 counts1 %
± 5 counts1 %
+ 5 counts± 1 %
± 5 countsResistance range 0 to 1000 Ω 0 to 1000 Ω 0 to 400 Ω 0 to 400 Ω 0 to 600 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 9999 Ω 0 to 400 KΩ 0 to 1500 ΩFrequency measurement range 5 to 400 Hz 5 to 1000 Hz 5 to 1000 Hz 15 to 1000 HzUnit powerAuto off • • • • • • • • • • • • • • • •Warranty and safetyWarranty (years) 2 2 2 2 3 3 3 3 3 3 3 3 1 3 1 2
Category ratings (EN61010-1) CAT III 600 V CAT IV 600 V, CAT III 1000 V
CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V, CAT III 1000 V
CAT IV 600 V, CAT III 1000 V
CAT III 300 V Cat II 300 V CAT III 300 V CAT IV 600 V, CAT III 1000 V