FRANKONIA
Electrics Military Innovations Automation Test SystemsAutomotive
Frankonia Total Solutions | Anechoic Chambers & Test Systems
Frankonia Excellent Performance ChambersAnechoic Chamber Solution with Frankosorb® AbsorbersA state-of-the-art SAC-10 chamber with a Quiet Zone of ø3.0m and double test axis2015 | Project located in Germany
Project Data & Features:• Chamber size approx. 21.6 x 13.7 x 8.5 m (SAC)• 10m double test axis chamber • Full lining with Frankosorb® P2400• Non-combustible absorbers according to
DIN EN 13501-1 (DIN 4102) Class A2 - s1 d0; (NRL 8093 class 1,2,3,4 and 5)
• H600 hybrid floor absorber for FU• P450 floor absorber for SVSWR• Floor absorbers storable in the chamber• ø2.0 m quiet zone at 3 m test distance (H 2.0 m)• ø3.0 m quiet zone at 10 m test distance (H 2.0 m)• ø4.0 m quiet zone at 10 m test distance (H 2.0 m)• Incl. turntable ø4.0 m with 5 tons, antenna mast
and test system• Flexible and high-performance chamber• Proven long-term stability with more than 25 years• Project located in Germany finished in June 2015
--a double axis
high-performancechamber with Frankosorb® P2400 (A2)
--
The leading technology in EMC solutions from Germany
Frankonia GmbHIndustriestr. 16 | 91180 Heideck | GermanyPhone: +49 9177 98-500Fax: +49 9177 98-520
FRANKONIA
MADE
IN
GERMANY
Performance at 3 m test distance and QZ ø2.0m
Field Uniformity (horizontal)• Frequency 80 MHz - 1 GHz
100% at max. 5.17 dB; 75% at max. 3.43 dB• Frequency 1 GHz - 18 GHz
75% at max. 3.86dB
Field Uniformity (vertical)• Frequency 80 MHz - 1 GHz
75% at max. 5.21 dB• Frequency 1 GHz - 18 GHz
75% at max. 4.33 dB
Performance at 10 m test distance and QZ ø3.0m
Frankosorb®
= + +
Efficient & StableQuality
Cost-savingSolution
High-end Performance
Frankosorb® Absorbers
The Frankonia Frankosorb® absorber technology combines a variety of high-performance standards in a single solution.
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_BK_H_3m_2m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
NSA
dev
iatio
n in
dB
Frequency in MHz
HLF
HUF
HLR
HUR
HLB
HUB
HLL
HUL
HLC
HUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_BK_V_3m_2m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
NSA
dev
iatio
n in
dB
Frequency in MHz
VLF
VUF
VLR
VUR
VLB
VUB
VLL
VUL
VLC
VUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_LP_H_3m_2m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
200 300 400 500 600 700 800 900 1000
NSA
dev
iatio
n in
dB
Frequency in MHz
HLF
HUF
HLR
HUR
HLB
HUB
HLL
HUL
HLC
HUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_LP_V_3m_2m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
200 300 400 500 600 700 800 900 1000
NSA
dev
iatio
n in
dB
Frequency in MHz
VLF
VUF
VLR
VUR
VLB
VUB
VLL
VUL
VLC
VUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_BK_H_10m_3m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
NSA
dev
iatio
n in
dB
Frequency in MHz
HLF
HUF
HLR
HUR
HLB
HUB
HLL
HUL
HLC
HUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_BK_V_10m_3m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
NSA
dev
iatio
n in
dB
Frequency in MHz
VLF
VUF
VLR
VUR
VLB
VUB
VLL
VUL
VLC
VUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_LP_H_10m_3m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
200 300 400 500 600 700 800 900 1000
NSA
dev
iatio
n in
dB
Frequency in MHz
HLF
HUF
HLR
HUR
HLB
HUB
HLL
HUL
HLC
HUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_NSA_Eurofins_2015.xlsx / Dia_LP_V_10m_3m_A1
-5
-4
-3
-2
-1
0
1
2
3
4
5
200 300 400 500 600 700 800 900 1000
NSA
dev
iatio
n in
dB
Frequency in MHz
VLF
VUF
VLR
VUR
VLB
VUB
VLL
VUL
VLC
VUC
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_SVSWR_Eurofins_2015.xlsx / Dia_H_3m_3m
0
1
2
3
4
5
6
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Svsw
r in
dB
Frequency in GHz
HC
HF
HR
HL
HT
FRANKONIA GmbH Uwe Panten, 14.03.16 Auswertung_SVSWR_Eurofins_2015.xlsx / Dia_V_3m_3m
0
1
2
3
4
5
6
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Svsw
r in
dB
Frequency in GHz
VC
VF
VR
VL
VT