LS1 GE1/1 Super Chamber – Powering and Signals
2 x HV Lines (8mm-diam) to USC
4 x LV Lines (10mm-diam)
4 x Fiber lines to USC
GE1/1 PP
To UXC YE-1 Tower
4 x Fiber lines to PP CSC TMB YE-1 X1• 2 HV Lines to USC• 4 LV Lines to UXC YE-1 Towers• 8 Fibers (cable with 12 fibers)• 4 lines to USC• 4 lines to CSC TMB
Via trigger tunnel
18/02/2013
![Page 3: GE1/1 Services and Strips PCB Andrey Marinov On behalf of CMS GEMs collaboration](https://reader036.vdocuments.net/reader036/viewer/2022062802/56649ea95503460f94bae0fa/html5/thumbnails/3.jpg)
Services for GE1/1 Project
• During LS1 I have to install and commission all the services needed for the CY2016 slice test
• Gas and Cooling are defined.• Cables and connections are still under
discussions.– HV lines – Defined OK– Fiber cables – Not defined yet.– LV lines – Not defined yet.– Cu Lines for control and signals – Not defined yet.
![Page 4: GE1/1 Services and Strips PCB Andrey Marinov On behalf of CMS GEMs collaboration](https://reader036.vdocuments.net/reader036/viewer/2022062802/56649ea95503460f94bae0fa/html5/thumbnails/4.jpg)
To Summaries
• In order to have the cable services installed in time we should freeze the floating points above very soon.
• Routing of spare lines can be an option.• Once we declare our cable schema in front of
the CMS coordinators there will be no change after.
![Page 5: GE1/1 Services and Strips PCB Andrey Marinov On behalf of CMS GEMs collaboration](https://reader036.vdocuments.net/reader036/viewer/2022062802/56649ea95503460f94bae0fa/html5/thumbnails/5.jpg)
Development of the Multilayer GEM PCB
• A small 30x30 cm^2 strips board was fabricated• The design of a trial 30x30 cm^2 multilayer PCB is
under way. A electrical diagram for the connections needs to be made ASAP.
• If the noise tests are showing no perturbation of the signal due to the VFAT digital activity we can launch the design of the full-size Multilayer GEM PCB for connections and Power.
![Page 6: GE1/1 Services and Strips PCB Andrey Marinov On behalf of CMS GEMs collaboration](https://reader036.vdocuments.net/reader036/viewer/2022062802/56649ea95503460f94bae0fa/html5/thumbnails/6.jpg)
30x30 cm^2 Test Board
![Page 7: GE1/1 Services and Strips PCB Andrey Marinov On behalf of CMS GEMs collaboration](https://reader036.vdocuments.net/reader036/viewer/2022062802/56649ea95503460f94bae0fa/html5/thumbnails/7.jpg)
30x30 cm^2 Test Board
![Page 8: GE1/1 Services and Strips PCB Andrey Marinov On behalf of CMS GEMs collaboration](https://reader036.vdocuments.net/reader036/viewer/2022062802/56649ea95503460f94bae0fa/html5/thumbnails/8.jpg)
Thank you