HC6 RANGEVoltages 120V - 690V
Outputs from 800 - 1438 kVA (4 pole)
F E A T U R E S :
• Permanent Magnet Generator (PMG) provides an isolated power supply to the
excitation control system
• MX321 (PMG) as standard with 0.5% Regulation and 3 phase sensing
• 2/3 pitch winding as standard, to avoid excessive neutral currents
• Single or two bearing construction with dynamically balanced rotor and
sealed-for-life bearings
• Easy access for installation and maintenance
• Built to conform with all leading industrial and marine standards
• IP23 as standard
product prof i le
O P T I O N S & A C C E S S O R I E S :• Temperature Indication RTD’s
• Winding Protection Thermistors
• Air Condensation Heaters
• Air Filters
• Quadrature Droop kit for Parallel Operation
• Power factor Controller
• Diode Failure Unit
• Excitation Loss Module
• Manual Voltage Regulator
HC-6 7/11/02 12:23 pm Page 1
HC 6 RANGEproduct prof i le
T Y P I C A L A P P L I C AT I O N S :Combined Heat & PowerParallel OperationPeak ShavingBase Load PrimeStandbyRentalTelecommunicationMarine/Offshore
3 Phase Ratings for STAMFORD HC6 Generators
50Hz (1500 rpm)4 Pole
Rating/AmbientApplication/Temp
RiseVoltage
HCI 6G kVAkW
HCI 6H kVAkW
HCI 6J kVAkW
HCI 6K kVAkW
Base 40ºCContinuous
125ºC
Peak 40ºC
Standby 150ºC
Peak 27ºC
Standby 163ºC
Base 40ºCContinuous
125ºC
Peak 40ºC
Standby 150ºC
Peak 27ºC
Standby 163ºC
60Hz (1800 rpm)
800
640
910
728
1000
800
1110
888
810
648
940
752
1030
824
1130
904
800
640
910
728
1000
800
1110
888
820
656
960
768
1060
848
1180
944
830
664
980
784
1070
856
1190
952
820
656
960
768
1060
848
1180
944
850
680
1000
800
1100
880
1220
976
860
688
1010
808
1100
888
1230
984
850
680
1000
800
1100
880
1220
976
875
700
1025
820
1150
920
1275
1020
925
740
1063
850
1200
960
1338
1070
1000
800
1125
900
1300
1040
1438
1150
913
730
1088
870
1206
965
1350
1080
969
775
1125
900
1250
1000
1413
1130
1046
837
1188
950
1350
1080
1525
1220
950
760
1125
900
1250
1000
1400
1120
1000
800
1163
930
1300
1040
1463
1170
1088
870
1219
975
1400
1120
1575
1260
380 400 415 380 400 415 380 400 415 416 440 480 416 440 480 416 440 480
3 Phase Ratings for STAMFORD HC6 Generators
50Hz (1000 rpm)6 Pole
Rating/AmbientApplication/Temp
RiseVoltage
HCI 6G kVAkW
HCI 6H kVAkW
HCI 6J kVAkW
HCI 6K kVAkW
Base 40ºCContinuous
125ºC
Peak 40ºC
Standby 150ºC
Peak 27ºC
Standby 163ºC
Base 40ºCContinuous
125ºC
Peak 40ºC
Standby 150ºC
Peak 27ºC
Standby 163ºC
60Hz (1200 rpm)
280
224
380
304
450
360
570
456
280
224
380
304
450
360
570
456
280
224
380
304
450
360
570
456
291
233
395
316
468
374
593
474
291
233
395
316
468
374
593
474
291
233
395
316
468
374
593
474
300
240
407
326
482
386
610
488
300
240
407
326
482
386
610
488
300
240
407
326
482
386
610
488
331
265
450
360
531
425
675
540
350
280
475
380
563
450
713
570
350
280
475
380
563
450
713
570
344
275
468
374
552
442
702
562
364
291
494
395
586
469
742
594
364
291
494
395
586
469
742
594
354
283
482
386
586
454
722
578
375
300
508
406
602
482
763
610
375
300
508
406
602
482
763
610
380 400 415 380 400 415 380 400 415 416 440 480 416 440 480 416 440 480
NEWAGE International Limited PO Box 17 · Barnack Road · Stamford Lincolnshire · PE9 2NB · EnglandTel.: +44 (0) 17 80 48 40 00 · Fax: + 44 (0) 17 80 48 41 00 e-mail: [email protected] · internet: www.newage-avkseg.com
©Newage International 2002
Due t
o ou
r poli
cy o
f con
tinuo
us im
prov
emen
t, de
tails
in th
is lea
flet w
hich
were
corre
ct at
time
of p
rintin
g ma
yno
w be
due
for a
mend
ment
. Inf
orma
tion
includ
ed m
ust t
here
fore
not
be r
egar
ded
as b
inding
PM_H
C6 P
P GB
_11.
02_0
2_GB
Standard Winding (311)
HC-6 7/11/02 12:23 pm Page 2