Page 1: INS735 Attic Card1 - CADdetails · 2016. 1. 21. · Application Coverage Chart 30 lbs (13.6 kg) INS735 THIS IS GREENFIBER® ALL BORATE LOOSE FILL FORMULA INSULATION ATTIC CARD GreenFiber

INS735 30 lbs (13.6 kg) Application Coverage Chart

THIS IS GREENFIBER® ALL BORATE LOOSE FILL FORMULA INSULATION

ATTIC CARD

GreenFiber provides outstanding thermal performance, fire-resistance and sound control. Consisting of up to 85% recycled content, GreenFiber Insulation is specially treated for flame resistance. R-value means resistance to heat flow - the higher the R-value, the greater the insulation power.

CERTIFICATION: This insulation has been installed in conformance with the above recommendations, to provide a value of R-_______ using ______ bags of this insulation to cover ______ square feet of area.

Builder’s Signature: __________________________________________

Company Name: ____________________________________________

Date: ____________

Applicator’s Signature: _______________________________________

Company Name: ____________________________________________

Date: _____________

FOR MORE INFORMATION CONTACT: GreenFiber Corporate Office 2500 Distribution Street, Suite 200 Charlotte NC 28203 (p) 800.228.0024 (f) [email protected]

MANUFACTURING LOCATIONS:

PM-6.3-56 Rev I 03/15

THIS COVERAGE CHART IS FOR DRY APPLICATIONS ONLY AND IS BASED ON THE KRENDL KS200, WITH MATERIAL APPLIED DRY. FOR MAXIMUM COVERAGE PER BAG (ADJUSTED FOR FRAMING), THE FRAMING FACTOR FOR 16" OC STUD SPACING IS 9.375%; FOR 24" OC STUD SPACING THE FRAMING FACTOR IS 6.25%.

1321

2x42x6

3.55.5

0.791.24

42.026.8

40.625.9

Spray Applied Sidewall Applications (2.7 pcf minimum installed density) 30 lbs. (13.6 kg) INS735

Estructura

Framing Installed Thickness(inches)

(pulgadas)Espesor instalado

2/BagMaximum Coverage Per Bag

(Adjusted for Framing) ft Cobertura máxima por bolsa

(con compensación para la estructura)ft2/Bag

2

Minimum Wt.Per Square Foot

lb/ftPeso mínimo por

pie cuadrado lb/ft2 (16” oc) (24” oc)

3.243.855.656.547.728.899.4711.2011.7712.9114.0514.3314.6217.44

3.013.585.256.087.188.278.81

10.4210.9512.0113.0713.3313.6016.22

89.073.748.040.533.428.226.121.320.017.916.015.615.212.0

11.213.620.824.729.935.438.346.950.055.962.564.165.883.3

0.3370.4070.6250.7400.8981.0621.151.411.501.681.881.921.982.49

98.281.352.844.035.830.027.622.320.918.616.616.215.712.4

10.212.318.922.727.933.336.244.847.853.860.261.763.780.6

1113192226303238404448495060

R-Value at 75° F Mean

Temp.Valor de

resistencia termica

(valor R) a 75 F de

temperatura media

Minimum Thickness (inches)

Expesor minimo (en pulgadas)

Initial Installed

Thickness

Espesor inicial

instalado

Settled Thickness

Espesor asentado

Maximum Sq. Ft. per Bag

Pies cuadrados máximos por bolsa

Net Coverage (no adjustment for framing)

Cubertura neta (sin compensación para el estructura)

Mimimum Bags per

1,000 Sq. Ft.

Cantidad minima de bolsas por 1,000

pies cuadrados

Minimum Weight per

Sq. Ft.

Peso minimo por pie cuadrado

Maximum Sq. Ft. per Bag

Pies cuadrados máximos por bolsa

Mimimum Bags per

1,000 Sq. Ft.

Cantidad minima de bolsas por 1,000

pies cuadrados

Net Coverage (adjusted for 2” x 6“ framing on 16” centers)

Cobertura neta (con compensación para una estructura de 2" x 6" en

centros de 16")

Thermal Resistance(R value)

Resistencia térmic a(R)

THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 30 LBS USING A VOLUMATIC III, 3rd GEAR AND 8" GATE. THE CHART IS BASED ON SETTLED THICKNESS AND IS FOR ESTIMATING PURPOSES ONLY. DO NOT EXCEED MAXIMUM SQUARE FEET COVERAGE PER BAG. THE APPLICATOR MUST INSTALL BOTH THE MINIMUM NUMBER OF BAGS PER 1000 SQ. FT. AND THE MINIMUM INSTALLED THICKNESS TO INSURE THE STATED R-VALUE HAS BEEN REACHED. FAILURE TO MEET BOTH THESE REQUIREMENTS MAY PREVENT THE APPLICATION OF SPECIFIED R-VALUE. THE INSTALLED MOISTURE CONTENT MUST BE BETWEEN 16% AND 25% IN ATTIC APPLICATIONS. THIS COVERAGE CHART DOES NOT APPLY TO DRY LOOSE-FILL ATTIC/FLOOR APPLICATIONS. JOB CONDITIONS, APPLICATION TECHNIQUES, EQUIPMENT, AND SETTINGS CAN INFLUENCE ACTUAL COVERAGE. MINIMUM NET WEIGHT IS 28.5 LBS.

THIS COVERAGE CHART IS FOR DRY APPLICATIONS ONLY AND IS BASED ON THE KRENDL KS200, WITH MATERIAL APPLIED DRY.

1321

2x42x6

3.55.5

1.021.60

32.420.6

31.319.9

Dry Dense Sidewall Applications (3.5 pcf minimum installed density) 30 lbs. (13.6 kg) INS735

Estructura

Framing Installed Thickness(inches)

(pulgadas)Espesor instalado

2/BagMaximum Coverage Per Bag

(Adjusted for Framing) ft Cobertura máxima por bolsa

(con compensación para la estructura)ft2/Bag

2

Minimum Wt.Per Square Foot

lb/ftPeso mínimo por

pie cuadrado lb/ft2 (16” oc) (24” oc)

Thermal Resistance(R value)

Resistencia térmic a(R)

Albany, NY Belchertown, MA Delphos, OH Norfolk, NE Chandler, AZ Salt Lake City, UT Tampa, FL Waco, TX Wilkes-Barre, PA