Odyssey Thin Plate Technology – The Advantages
Highest volumetric and gravimetric energy density
Increased shelf life (up to 2 years @ 20°C)
Extremely high energy and power density
Superb engine start performance
Rapid recharge capability
Very low internal resistance
Optimised for deep discharge cyclic applications
Resistant to abusive over discharge
ODYSSEY THIN PLATE TECHNOLOGY = MORE PLATES IN EACH 2 VOLT CELLRESULT = MORE CRANKING AMPS & SUPERIOR POWER & ENERGY DENSITY
ODYSSEY THIN PLATE THE ADVANTAGE
ODYSSEYTRADITIONAL LEAD CALCIUM
ENERSYS MANUFACTURINGPROCESS ALLOWS PROCESSING OF PURE LEAD GRID RESULT : 1mm THIN
CONVENTIONAL BATTERY BOOKMOLD CASTING REQUIRES ARTIFICIAL HARDENERS TO PROCESS GRID
RESULT : 2 - 4 mm THICK
SPACE SAVING
• On average:-
• Odyssey occupies 30% less space
• More Power Less Space
BatteryCabinet
BatteryCabinet
Conventional Lead acid
TPPL
Odyssey
STORAGE
AVAILABLE CAPACITY AS A FUNCTION OF OPEN CIRCUIT VOLTAGEDURING STORAGE @ 20 DEGREES CELSIUS
2.100
2.105
2.110
2.115
2.120
2.125
2.130
2.135
2.140
2.145
2.150
2.155
2.160
2.165
2.170
0 3 6 9 12 15 18 21 24 27
Months
VO
LT
S/C
EL
L
70
72
74
76
79
81
83
85
87
89
91
94
96
98
% S
TA
TE
OF
CH
AR
GE
ENGINE START COLD CRANK ENGINE START ODYSSEY PC2250.
850 AMPS FOR 30 SECONDS @ -18°C
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
-0.5 1.5 3.5 5.5 7.5 9.5 11.5 13.5 15.5 17.5 19.5 21.5 23.5 25.5 27.5 29.5 31.5
TIME (SECONDS)
ON
LO
AD
VO
LT
S
EFFECT OF CHARGE VOLTAGE ON RECHARGE TIME TO 100% OF DISCHARGED Ah. 2.27 VOLTS/CELL vs 2.4 VOLTS/CELL FOLLOWING 100% DOD AT VARIOUS RATES.
CURRENT LIMIT 1.5 * C3A AT 20 DEGREES CELSIUS
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
6.5
7
7.5
8
8.5
9
C1 C3 C10
DISCHARGE RATE
TIM
E T
O 1
00%
OF
DC
H A
h R
ET
UR
NE
D .
2.27VPC 2.4VPC
RECHARGE
RECHARGE
CHARGE PROFILE 24V * PC1700 FOLLOWING 80% DOD C5 CAPACITY DISCHARGE
0
5
10
15
20
25
30
35
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
Time (Minutes)
Vo
ltta
ge
(V)
0
5
10
15
20
25
30
35
Cu
rre
nt
(Am
ps
)
Voltage Current
RECHARGE
PC1700, RECHARGE PROFILE (Ah in) FOLLOWING 80% DOD C5 DISCHARGE.
0
10
20
30
40
50
60
70
80
90
100
110
120
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
TIME (MINS)
% O
F D
ISC
HA
RG
E A
h R
ET
UR
NE
D
RECHARGETIME TO 80% STATE OF CHARGE VS DEPTH OF DISCHARGE AS A FUNCTION OF CURRENT LIMIT
(2.40 VOLTS/CELL)
0
0.5
1
1.5
2
2.5
3
3.5
0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00%
DEPTH OF DISCHARGE
TIM
E T
O 8
0%
ST
AT
E O
F C
HA
RG
E (
HR
S)
.
0.2C5 AMPS 0.3C5 AMPS 0.4C5 AMPS 0.5C5 AMPS 0.8C5 AMPS
RECHARGE
TIME TO 100% STATE OF CHARGE VS DEPTH OF DISCHARGE AS A FUNCTION OF CURRENT LIMIT (2.40 VOLTS/CELL)
0
1
2
3
4
5
6
7
0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00%
DEPTH OF DISCHARGE
TIM
E (
HR
S)
0.2C5 AMPS 0.3C5 AMPS 0.4C5 AMPS 0.5C5 AMPS 0.8C5 AMPS
CYCLING PERFORMANCE
PC2250 CYCLE LIFE PERFORMANCE. DCH 50A FOR 1 HOUR, CHARGE FOR 2 HOURS AT 2.4VOLTS/CELL
FULL C5 CAPACITY EVERY 50 CYCLES
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
6.5
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700
CYCLE NUMBER
DC
H T
IME
(H
RS
)
.
CYCLING PERFORMANCE
PC2250 FAST CHARGE CYCLIC EVALAUATION. CHARGE 2.4VOLTS/CELL TO OVERCHARGE FACTOR OF 1.03 FOLLOWING 60% & 80% C5 DOD
8
8.5
9
9.5
10
10.5
11
11.5
12
12.5
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
CYCLE NUMBER
EN
D O
F D
CH
VO
LT
S
.
60% dod 103% charge (50A LIMIT) 80% dod 103% charge (50A LIMIT)
CYCLING PERFORMANCE
Odyssey PC1700, 80% DEPTH OF DISCHARGE C5 CYCLING, CHARGE 2.4Vpc: 45A : 4 hours
8
8.5
9
9.5
10
10.5
11
11.5
12
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750
CYCLE NUMBER
EN
D O
F D
CH
VO
LTS
CYCLING CHARACTERISTICSODYSSEY CYCLE LIFE AS A FUNCTION OF DEPTH OF DISCHARGE (C5 RATE)
(charge 2.40 Volts/cell)
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105
DEPTH OF DISCHARGE
NU
MB
ER
OF
CY
CL
ES
.
CYCLING CHARACTERISTICSCYCLE LIFE AS A FUNCTION OF DEPTH OF DISCHARGE
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105
DEPTH OF DISCHARGE
AP
PR
OX
IMA
TE
NU
MB
ER
OF
CY
CL
ES
. Leading Gel battery Odyssey