Download - point of level
Product ComparisonLevelPoint Level / Liquids16.01.2013 03:54 PM
1 / 3
Liquipoint T FTW32 Liquipoint T FTW31 One rod probe 11961Z
Measuring principle Conductive Conductive ConductiveCharacteristic / Application Compact rope probe with multi
point detection possible up to5 switch points. Simple ropeshortening possible
Compact rod probe withmultipoint detection, possible upto 5 switch points. Simple rodshortening.
One rod probe for high andextremely low temperature andhigh pressure. Corrosion resistant
Supply / Communication DC PNP 10,8V ... 45VRelay 20V ... 230V ACRelay 20V ... 55V DC
DC PNP 10,8V ... 45VRelay 20V ... 230V ACRelay 20V ... 55V DC
RelayPFM
Ambient temperature -40 °C ... 70 °C(-40 °F ... 158 °F)
-40 °C ... 70 °C(-40 °F ... 158 °F)
-200 °C ... 250 °C(-328 °F ... 482 °F)
Process temperature -40 °C ... 70 °C(-40 °F ... 158 °F)
-40 °C ... 100 °C(-40 °F ... 212 °F)
-200 °C ... 250 °C(-328 °F ... 482 °F)
Process pressure absolute / max.overpressure limit
Vacuum ... 10 bar(Vacuum ... 145 psi)
Vacuum ... 10 bar(Vacuum ... 145 psi)
Vacuum ... 160 bar(Vacuum ... 2320 psi)
Min. conductivity of medium 10 µS/cm 10 µS/cm 20 µS/cmMain wetted parts 316L, FEP, PPS 316L, PP, PPS Ceramic, 316TI
Max. tensile strength 500 N 1000 NProcess connection G 1 1/2
NPT1 1/2"G 1 1/2NPT1 1/2"
G 1/2
Process connection hygienicSensor length 0.25m ... 15m
(10" ... 590")0.1m ... 4m(3.9" ... 157")
0.1m ... 2m(3.9" ... 79")
Output DC PNPRelay
DC PNPRelay
Relay
Certificates / Approvals ATEXWHG/ Overfill preventionLeakage Detection Certificate
ATEXWHG/ Overfill preventionLeakage Detection Certificate
ATEXWHG/ Overfill prevention
SpecialitiesApplication limits Observe min. medium
conductivityObserve min. mediumconductivity
Observe min. mediumconductivity
Instrumentation CompactSeparate
CompactSeparate
Separate
Electronic insert PFM: EC17Z, EC27ZComponents Transmitter: FTW325 Transmitter: FTW325 Transmitter: FTW325
Product ComparisonLevelPoint Level / Liquids16.01.2013 03:54 PM
2 / 3
One rod probe 11375Z Triple rod probe 11363Z Double rod probe 11362Z
Measuring principle Conductive Conductive ConductiveCharacteristic / Application One rod probe for high
temperature and high pressure.corrosion resistant
Triple rod probe with high-classmedia contacting wetted parts
Double rod probe with high-classmedia contacting wetted parts
Supply / Communication Relay Relay RelayAmbient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)-20 °C ... 80 °C(-4 °F ... 176 °F)
-20 °C ... 80 °C(-4 °F ... 176 °F)
Process temperature -40 °C ... 135 °C(-40 °F ... 275 °F)
-40 °C ... 150 °C(-40 °F ... 302 °F)
-40 °C ... 150 °C(-40 °F ... 302 °F)
Process pressure absolute / max.overpressure limit
Vacuum ... 50 bar(Vacuum ... 725 psi)
Vacuum ... 30 bar(Vacuum ... 435 psi)
Vacuum ... 30 bar(Vacuum ... 435 psi)
Min. conductivity of medium 20 µS/cm 20 µS/cm 20 µS/cmMain wetted parts PTFE, 316TI PTFE, PFA, 316 TI, Alloy B/C4,
Titan, Tantal, MonelPTFE, PFA, 316 TI, Alloy B/C4,Titan, Tantal, Monel
Max. tensile strengthProcess connection G 1 1/2 G 1 1/2A
NPT1 1/2"Flange DIN /ANSI
G 1 1/2ANPT1 1/2"Flange DIN /ANSI
Process connection hygienicSensor length 0.05m ... 2m
(2" ... 79")0.1m ... 4m(4" ... 157")
0.1m ... 4m(4ft ... 157ft)
Output Relay Relay RelayCertificates / Approvals ATEX
WHG/ Overfill preventionATEXWHG/ Overfill prevention
ATEXWHG/ Overfill prevention
SpecialitiesApplication limits observe min. medium conductivity Observe min. medium
conductivityObserve min medium conductivity
Instrumentation seperate Seperate SeparateElectronic insert
Components Transmitter: FTW325 Transmitter: FTW325 Transmitter: FTW325
Product ComparisonLevelPoint Level / Liquids16.01.2013 03:54 PM
3 / 3
One rod probe 11371 Pump Protection FTW360 Liquipoint FTW33
Measuring principle Conductive Conductive ConductiveCharacteristic / Application One rod probe. Simple rod
shortening or rod change onlocation
Compact limit switch for pumpprotection,Active build up compensation,Flush mounting
Compact point level switch forusing in pipes and in storage,mixing and process vessels withor without an agitator,Active build up compensation,Flush mounting
Supply / Communication Relay 21V ... 253V AC20V ... 200V DC
10…30 V DC
Ambient temperature -20 °C ... 120 °C(-4 °F ... 248 °F)
-20 °C ... 60 °C(-4 °F ... 140 °F)
-40 ... 70°C-40 ... 158°F
Process temperature -20 °C ... 120 °C(-4 °F ... 248 °F)
-20 °C ... 100 °C(-4 °F ... 212 °F)
Standard: -20 ... 100°CCleaning:-20 ... 150°C for 1h-4 ... 302°F for 1h
Process pressure absolute / max.overpressure limit
Vacuum ... 10 bar(Vacuum ... 145 psi)
Vacuum ... 10 bar(Vacuum ... 145 psi)
0 ... 25 bar abs0 ....362,5 psi abs
Min. conductivity of medium 20 µS/cm 10 µS/cm 1µS/cmMain wetted parts PFA, 316TI 1.4571, PTFE Sensor: 316L
Sensor isolation: PEEKMax. tensile strengthProcess connection G 1 1/2A
EinschweißstutzenG3/4 Thread G1, G1/2, G3/4, M24
Process connection hygienic Clamp ISO 2852 1 to 1 1/2", 2",DIN11851 Pipe union
Sensor length 0.05m ... 2m(2" ... 79")
Output Relay Relay DC PNPCertificates / Approvals EHEDG
3ASpecialities CIP suiteable CIP and SIP suiteable
Application limits Observe min. mediumconductivity
Observe minimum mediumconductivity
Conductive foam is recognizes asa liquid
Instrumentation Seperate CompactElectronic insert DC PNP
Components Transmitter: FTW325