RASI 700 combined emissions combustion and BIOGAS analyser
Portable combustion and emissions analysersA full range of accurate, robust and versatile portable analysers for industrial measurements
RASI 800 MCERTS certified, suitable forEA compliance emissions reporting
Emissions & calibration instruments
RASI 900 semi-continuous monitoring meets EPA protocol for emissions reporting
Maximum Gas Sensors at the same time 8 8 9
Gas measurements
O2 sensor ( 0-25 % ) standard standard standard
CO H2 compensated sensor ( 0-10.000 ppm) optional optional standard
Low CO H2 compensated sensor (0-500 ppm, 0.1 ppm resolution) optional optional optional
High CO sensor (0-20.000 ppm) optional optional optional
CO% sensor (0-10 %) optional optional optional
NO sensor (0-5000 ppm) optional optional optional
LOw NO sensor (0-500 ppm, 0.1 ppm resolution) optional optional optional
NO2 sensor (0-1000 ppm) optional optional optional
Low NO2 sensor (0-500 ppm, 0.1 ppm resolution) n/a n/a optional
SO2 sensor (0-1000 ppm) optional optional optional
H2S sensor (0-2500 ppm) optional optional optional
H2 sensor (0-1 %) n/a n/a optional
CO % (0-10 %NDIR) n/a optional optional
CO2% NDIR optional optional optional
HC(CH4) % (0 to 5 % NDIR) n/a optional optional
HC (40000 ppm NDIR) optional optional n/a
HC ppm Low range (0-1000 ppm NDIR) n/a n/a optional
HC ppm C3H8 (0 to 5000 ppm NDIR) n/a optional optional
CH4 % (0-100 % Biogas NDIR) optional n/a optional
CO2% (0-100 % Biogas NDIR) optional n/a optional
H2% ( 0-100 % TDC) n/a n/a optional
Other measurements
Velocity optional optional optional
Flow/Flow Mass optional optional optional
Temperature standard standard standard
Draught, Pressure and differential standard standard standard
Gas Sample Conditioning
Manual Water trap standard n/a n/a
Gas Cooler and condensate pump n/a standard standard
Line Filter standard standard standard
NOx filter for CO standard standard standard
Fresh-air in valve for “auto set to zero” and long term measurement n/a standard standard
CO sensor protection protection Optional standard standard
Communications/storage
Bluetooth standard standard optional
SD card standard standard optional
USB standard standard n/a
RS232 n/a n/a standard
Internal Memory standard standard standard
Data logging ( auto) optional standard standard
Emissions Calculations standard standard standard
Combustion Calculation standard standard standard
Fuel list standard standard standard
Printer optional standard standard
Sampling probes
Standard modular sampling probe with Viton Line optional optional optional
Industrial Probe with heated head and glass wool filter with Viton Line n/a optional optional
Heated Line n/a n/a optional
Probe Max temperature 1200 °C 1200 °C 1700 °C
Emissions Analyser Selection Guide
RASI 800 Portable Emissions & Combustion Analyser
Superior Peltier Gas Sample ConditioningThe Peltier gas cooler and the condensate pump automatically removes moisture from the gas stream and provides a dry sample for accurate compliance testing as indicated by the regulatory Agency. It also protects the measurement cells from moisture which is the main cause of sensor failure.
CO sensor protectionTo protect the CO cell from unexpected excessive levels of CO ( threshold user selectable), the analyser automatically switches to the higher range CO sensor ( if a 2nd sensor is installed). The Low CO is automatically purged with a dedicated pump which supplies ambient air to protect the sensor.
NDIR sensor for HC and CO2%New developed dual NDIR bench for direct CO2% measurement ( instead of calculated) and HC in ppm value.NDIR technology for HC offers a much wider scope of application compared to the traditional Pellistor type sensor as it does not require minimum O2 level to function.
Semi Continuos monitoringThe wake and sleep mode takes gas measurements at user defined intervals. During the sleep mode the analyser is purged with ambient air.Measurement data are automatically saved in the internal memory of the RCU and ready to be exported to the SD card in CSV format.
RCU Wireless remote control unitUse the wireless RCU to remotely control all the functions of the analyser and display the measurement value from a comfortable location.
•�Remotely�control�all�the�functions�of�the analyser including launching an auto-zero•�Display�measurement�value�on�large�3.5”�TFT graphic colour display•�The�long�range�Bluetooth®����������������������eliminate the needs of long sampling probes•�Automatic�or�manual�data�logging�with�data export to integrated SD card•�Intuitive�tasks�oriented�application�menu�for easy operation•�Use�as�separate�manometer,�flow�meter�or�thermometer with-out carrying the base unit
The dedicated task menu gives direct access to your application. Simply select your�“Task”,�i.e�flue�gas�measurement,�your�measurement�programme,�for�example�“Engine Emissions “ and analyser is ready to operate.Up to 4 measurements programme can be configured with the desire settings such as O2% reference, fuel, practical order of the display measurements.
Select a Task Select an Application Log your data Start Measuring
Simplified operation with the Intuitive Task
The RASI 800 MCERTS certified emissions analyser is suitable for compliance emissions reporting
Key Features
Sensors conditioning technology deliver best accuracyBoth the electrochemical and NDIR are continuously temperature monitored and compensated. A sophisticated software matrix compensate for sensors cross-interference to deliver best accuracy.
Features
Max Sensors 8 Standard Option
Built-in gas cooler and condensate pump •
O2 oxygen cell ( all other cells are optional) •
CO sensor protection •
Automatic set to zero valve for long term measurement •
Condensate monitor and alarm •
Flow measurement •
RCU remote control unit •
Sampling probes •
Measurements Capabilities
•O2�LL •CO •Low�CO
•NO •NO2 •NOx
•Low�NO •CO% •SO2
•H2S •CO2%�NDIR •HC�NDIR
•Smoke •Flow •Pressure
•Temperature •Draught
RASI 800 Base UnitThe hart of the analyser, built in a robust protective transport case•Contains�up�to�8�measurement�cells•�Gas�sampling�pump,�Peltier�gas�cooler,�condensate pump and filters•Set�to�zero�valve•CO�sensor�protection•Gas�Sampling�Probe�connection•Integrated�fast�printer
RASI 800 Portable Emissions & Combustion Analyser
Specifications
Range Accuracy Resolution Sensor Type
02 0-25 % ± 0.2% Vol abs 0.01% Vol EC
CO(H2 compensated) 0-10000 ppm ± 10 ppm or ± 5% rdg up to 4,000 ppm ± 10 % rdg from 4,000 to 10,000 ppm 1 ppm EC
CO 0-20000 ppm ± 100 ppm or ± 5% rdg up to 4,000 ppm ± 5 % rdg from 4,000 to 20,000 ppm 1 ppm EC
CO % 0-10% ± 0.02% of rdg up to 4 % ± 10% of rdg up to 4 % to 10 % 0.01% EC
Low CO(H2 compensated) 0-300 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC
NO 0-5000 ppm ± 5 ppm or ± 5% rdg up to 1,000 ppm ± 10 % rdg from 1,000 to 5,000 ppm 1 ppm EC
Low NO 0-500 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC
NO2 0-1000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 1,000 ppm 1 ppm EC
SO2 0-5000 ppm ± 10 ppm or 5% rdg up to 2,000 ppm ± 10 % rdg from 2,000 to 5,000 ppm 1 ppm EC
H2S 0-2000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 2,000 ppm 1 ppm EC
1 or 2 gas NDIR Bench
CO2 % 0-40 % ± 0.3% vol or ± 5% rdg 0.01% Vol NDIR
HC ppm/HC % 0-40000 ppm/0-4% ± 100 ppm./0.01% 100 ppm/0.01% NDIR
3 GAS NDIR Bench
CO2% 0-30 % ± 0.5% vol or ± 3% rdg 0.01% Vol NDIR
CO% 0-10 % ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR
HC (CH4) or 0-3% ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR
HC (C3H8) 0-5000 ppm ± 30 ppm or ± 3% rdg 1 ppm NDIR
Temperature and Pressure/Smoke
Gas Temperature -50-1200 °C ± 2 °C 0.1 °C TC type K
Air Temperature -50 °C to 100 °C ± 1 °C 0.1 °C TC Type K
Draught/Diff Pressure ( Base) -100 to 100 hPa ± 0,02 hPa 0.01 hPa Piezoresistive
Draught/Diff Pressure ( RCU) -200 to 200 hPa ± 0,02 hPa 0.01 hPa Piezoresistive
Flow Velocity 3 to 100 m/sec ± 1 m/sec or ± 3 % of rdg 0.1 m/sec Pitot Tube
Smoke ( soot) manual by smoke pump or automatic using heated probe with filter
Calculations
Efficiency 0 to 120 % 0.1 % Calculated
Air Ratio 1 to 9.99 0.01 Calculated
Excess Air 0 to 99,9% 0.1% Calculated
Heat losses 0 to 99.9 % 0.1% Calculated
CO2% ( when CO2% NDIR not installed 0 to CO2% max ± 0.3% vol 0.1%
Flue Gas Dew Point 0 to 99.9 C 0.1 C Calculated
Fuel Selection most common fuels plus user definable
Emissions Calculations Oxygen normalization, automatic conversion ppm, mg/m3 for all toxic gas
Memory, data capture and communication
Storage medium 16000 logs on internal memory, 2GB on standard SD card, Data export to CSV file, download via SD card included as standard
Digital communications mini USB, Bluetooth
General
Gas Sample Preparation Integral Peltier Cooler with constant 5 °C dew Point, perilstatic pump for condensate removal
RCU BASE UNIT
Display 3.5” TFT colour display, 6 lines, full graphic no display
Weight, Dimension ( W x L x H) 6 Kg, 470x314x 235 with case and RCU
IP protection IP20 IP 20
AC/DC Power Inductive trough base unit 100-240 VAC, 50-60 Hz, 12 VDC
Battery, Battery life Li/ION, 30 hours Li/ION 20 hours, 10 hours with cooler on
Operating/Storage Temperature 5 to 45 °C / -20 to 50 °C 5 to 45 °C / -20 to 50 °C
Warranty 2 years instruments 1 year CO, NO,NO2,SO2,H2S cells, 2 years O2 cell, 2 years NDIR
RASI 800 Portable Emissions & Combustion Analyser
Online View Software
Supplied as standard with the analyser, this powerful software allows you to view data in real time on a laptop or PC.Data are displayed in TEXT, GRAPHICAL or BAR format. The software automatically saves and creates an excel file of the measurements taken. Communication is established via bluetooth or USB port.
Data Management
Save time and ensure traceability. Simply upload your sites and log measurement values under each site:Our new concept include:•Site�Administration•Data�administration•Data�Export�on�SD�card•Automatic�data�logging
How to order
to make your selection please state the following:•�Gas�to�be�measured�(�the�analyser�comes standard with O2 cell only) •�Maximum�6�electrochemical�cells�and�one NDIR bench can be installed at the same time•Probe�length�•Temperature�of�the�stack
When selecting your analyser, please consider a few important factors:
•�True�NOx�require�both�NO�and�NO2�����������������������measurement cells installed. Most industrial applications will require NO2 cell installed to provide correct NOx reading.•�CO2�%�calculated�values�which�are�fuel dependant can be very erratic. Your application might require an NDIR infrared sensor ( ie stack emissions, CHP engines, Cement plants).
EiUK offer a large selection of gas sampling probes to match your application. All our probes are supplied with a special Viton line to eliminate sample absorption and to increase the analyser response time. A choice of standard or industrial probes is outlined below.
Standard Gas Sampling Probe
The standard sampling probe is available in different lengths and different materials. It comes complete with integrated thermocouple for temperature reading and positioning cone. More than one probe shaft can be ordered.
Probe Shaft Stainless Steel: Tmax 850 °Clengths: 360, 500, 750 mm, 1m,1.5m, 2 m
Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5 and 2m
Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7 or 5 m
Industrial Gas Sampling Probe with heated and unheated line
The industrial gas sampling probes come with heated glass wool replaceable filter. and choice of heated or unheated line with integrated type K or S thermocouple.
Probe Shaft Stainless Steel: Tmax 850 °Clengths: 380, 500, 750 mm, 1m, 1.5m, 2m
Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5m and 2m
Probe Shaft Ceramic: T Max 1700 CAvailable Length: 1m.
Heated lineSelf regulated heated line (Tmax 160C)Length available 3 or 5 mInternal material: Special Viton Unheated lineLength available 3 or 5 m. Internal material: Special Viton
Gas Sampling Probes
Engine Probe
The engine probe is specifically designed for sampling on gas or diesel CHP engines: It features
•�Special�Viton�hose�for�maximum�NO2�accuracy•Temperature�measurement•Back�Pressure�measurements•Special�positioning�cone�spring�loaded
Probe Shaft Stainless Steel: Tmax 1200 °Clengths: 360, 500,
Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7
RASI 901 Portable Emissions Analyser
The toughest and rugged Portable Emissions Analyser ever built, suitable for long term measurements.
Superior Peltier Gas Sample ConditioningThe Peltier gas cooler and the condensate pump automatically removes moisture from the gas stream and provides a dry sample for accurate compliance testing as indicated by the regulatory Agency. It also protects the measurement cells from moisture which is the main cause of sensor failure.
The RASI 901 it is with-out doubt the most complete Portable Emissions Analyser available on the market today. The rugged construction, the easy to use task menu and the and superior sensors technology, delivers high accurate and repeatable readings overtime.
The advanced sample conditioner which includes an active Peltier cooler, moisture removal pump and self-regulated heated line, sets new standards in portable emissions monitoring.
Key Features
Heated Line A heated sample line is used to keep the gas sample above the dew point to prevent the absorption of gases into the water phase. This provides conditions for more accurate measurements as gases are not lost into the condensate. Given the solubility of NO2 , the heated line is recommended for maximising NOx accuracy readings.
A TRUE 9 gases analyser designed to cover all your applicationsUp to 6 electrochemical cells and one NDIR infrared bench can be installed at the same time to deliver the most comprehensive emissions analyser in the market
NDIR technology to detect HC ppm valuesA new developed infrared bench delivers extremely accurate readings down to ppm values for detecting low level of hydrocarbons in term on CH4 of C3H8.
Ideal for long term measurement cyclesIf your application requires long term measurements, then don’t look any further. The RASI 901 features the necessary hardware to be left in the stack for days, weeks or even months with-out compromising in accuracy or damaging the measurement cells. •�Heated�line•�Peltier�Cooler•Condensate�pump�for�water�removal•Automatic�set�to�zero�functionThe wake and sleep automatic programme allows you to measure and log data at defined intervals.
Large 10 lines back light display icon based displays all the parameters that you need for your application
Automatic data logging function
Measurements Capabilities
•O2�LL •CO •Low�CO
•NO •NO2 •NOx
•Low�NO/NO2 •CO% •SO2
•H2S •CO2%�NDIR •HC�NDIR
•H2 •Flow •Pressure
•Temperature •Draught •Smoke
Features
Standard Option
Maximum 9 gases
Built-in gas cooler and condensate pump •
O2 long life, CO (H2 compensated) •
Other measurements cells •
CO sensor protection
Automatic set to zero valve for long term measurement •
Pressure, draught, temperature •
Flow,�and�mass�flow�measurement •
Bluetooth, SD card •
Sampling probes •
Integrated fast printer •
Bluetooth® connectivity and new mobile app.The�standard�bluetooth®�allows�for�real�time data transfer to a PC or to an android base smart mobile device. The new free application speeds up your testing, keeps you away from dirty and noisy rooms and ensure data collection. There is no need anymore for long sampling lines or to stay close to the sampling points. Just enjoy the analyser reading from a more convenient location
•Connect•Start�measuring•Stop�pump•Save�data•Email�data�
RASI 901 Portable Emissions Analyser
SpecificationsRange Accuracy Resolution Sensor Type
02 0-25 % ± 0.2% Vol abs 0.01% Vol EC
CO(H2 compensated) 0-10000 ppm ± 10 ppm or ± 5% rdg up to 4,000 ppm ± 10 % rdg from 4,000 to 10,000 ppm 1 ppm EC
CO 0-20000 ppm ± 100 ppm or ± 5% rdg up to 4,000 ppm ± 5 % rdg from 4,000 to 20,000 ppm 1 ppm EC
CO % 0-10% ± 0.02% of rdg up to 4 % ± 10% of rdg up to 4 % to 10 % 0.01% EC
Low CO(H2 compensated) 0-300 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC
NO 0-5000 ppm ± 5 ppm or ± 5% rdg up to 1,000 ppm ± 10 % rdg from 1,000 to 5,000 ppm 1 ppm EC
Low NO 0-500 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC
NO2 0-1000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 1,000 ppm 1 ppm EC
Low NO2 0-500 ppm ± 3 ppm or ± 5% reading 0.1 ppm EC
SO2 0-5000 ppm ± 10 ppm or 5% rdg up to 2,000 ppm ± 10 % rdg from 2,000 to 5,000 ppm 1 ppm EC
H2S 0-1000 ppm ± 5 ppm or ± 5% rdg up to 50 ppm ± 10 % rdg above 50 ppm 1 ppm EC
H2 0-2 % ± 0.02 % rdg or ± 5 % of rdg up 1 %±10% rdg above 1 % 0.01% EC
1 GAS NDIR Sensor
CO2 % 0-40 % ± 0.3% vol or ± 5% rdg 0.01% Vol NDIR
3 GAS NDIR Bench
CO2% 0-50 % ± 0.5% vol or ± 3% rdg 0.01% Vol NDIR
CO% 0-10 % ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR
HC (CH4) or 0-5% ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR
HC (C3H8) or 0-5000 ppm ± 30 ppm or ± 3% rdg 1 ppm NDIR
HC (CH4) 0-10.000 ppm ± 30 ppm or ± 3% rdg 1 ppm NDIR
Temperature and Pressure
Gas Temperature -50-1700 °C ± 2 °C 0.1 °C TC type K/S
Air Temperature -50 °C to 100 °C ± 1 °C 0.1 °C TC Type K
Draught/Diff Pressure -100 to 100 hPa ± 0,02 hPa 0.01 hPa Piezoresistive
Flow Velocity/mass 3 to 100 m/sec ± 1 m/sec or ± 3 % of rdg 0.1 m/sec Pitot Tube
Calculations
Efficiency 0 to 120 % 0.1 % Calculated
Air Ratio 1 to 9.99 0.01 Calculated
Excess Air 0 to 99,9% 0.1% Calculated
Heat losses 0 to 99.9 % 0.1% Calculated
CO2% ( when CO2% NDIR not installed 0 to CO2% max ± 0.3% vol 0.1% Calculated
Fuel Selection Most common fuels plus user definable
Emissions Calculations O2 Corrections, automatic conversion ppm, mg/m3 for all toxic gases, mass measurement for SO2, NOx and CO using an optional pitot tube
Memory, data capture and communication
Storage medium 8500 logs on internal memory, 2GB on standard SD card, Data export to CSV file, download from Internal memory or via SD card (optional)
Digital communications RS232,�Bluetooth®
Analogue communications 8 x 4-20 mA output, 4-20 mA or 0-10 V input
General
Gas Sample Preparation Integral Peltier Cooler with constant 5 °C dew Point, Peristaltic pump for automatic condensate removal
Display Back light Graphic LCD display, 10 lines, full graphic, task oriented menu
Weight, Dimension ( W x L x H) 7 Kg, 530 x 490x 310
IP protection IP21
Power/Mains Ni-Mh Internal rechargeable batteries, AC 100-250 VAC, 47-63 Hz
Operating/Storage Temperature 5 to 45 °C / -20 to 50 °C
Warranty 2 years instruments 1 year CO, NO,NO2,SO2,H2S, H2 cells, 2 years O2 cell, 2 years NDIR
RASI 901 Portable Emissions Analyser
Ordering Information
to make your selection please state the following:•�Gas�to�be�measured�(�the�analyser�comes standard with O2 and CO(H2) cell only) •�Maximum�6�electrochemical�cells�and�one NDIR bench can be installed at the same time•Probe�type�and�length�•Temperature�of�the�stack
When selecting your analyser, please consider a few important fac-tors:
•�True�NOx�require�both�NO�and�NO2�����������������������measurement cells installed. Most of industrial application will require NO2 cell installed to provide correct NOx reading•�CO2�%�calculated�values�which�are�fuel dependant can be very erratic. If Your application might require an NDIR infrared sensor ( ie stack emissions, CHP engines, Cement plants)•�HC�in�diesel�engines�are�normally�at�ppm level in term of CH4
Online View Software
Supplied as standard with the analyser, this powerful software allows you to view data in real time on a laptop or PC.Data are displayed in TEXT, GRAPHIC or BAR format. The software automatically save and create an excel file of the measurements taken. Communication is established via bluetooth or RS233 port
Data Management
Save time and ensure traceability. Simply upload your sites and log measurement values under each site:Our new concept include:•Site�Administration•Data�administration•Data�Export�on�SD�card•Automatic�data�logging
Eiuk offer a large selection of gas sampling probes to match your application. All our probes are supplied with a special Viton line to eliminate sample absorption and to increase the analyser response time. A choice or standard or industrial probes are outlined below.
Standard Gas Sampling Probe
The standard sampling probe is available in different lengths and different materials. It comes complete with integrated thermocouple for temperature readings and positioning cone. More that one probe shaft can be ordered.
Probe Shaft Stainless Steel: Tmax 850 °Clengths: 360, 500, 750 mm, 1m,1.5m, 2 m
Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5 and 2m
Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose lenght: 2.7 or 5 mt
Industrial Gas Sampling Probe with heated and unheated line
The industrial gas sampling probes come with heated glass wool replaceable filter. and choice of heated or unheated line with integrated type K or S thermocouple.
Probe Shaft Stainless Steel: Tmax 850 °Clengths: 380, 500, 750 mm, 1m, 1.5m, 2m
Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5m and 2m
Probe Shaft Ceramic: T Max 1700 CAvailable Length: 1m.
Heated lineSelf regulated heated line (Tmax 160C)Length available 3 or 5 mInternal material: Special Viton Unheated lineLength available 3 or 5 m.Internal material: Special Viton
Gas Sampling ProbesRASI 901-MK Emissions Analyser for marine applications
The RASI901-MK Portable Emissions Analyser Marine Kit provides a reliable and accurate measurements for O2, CO, CO2, True NOx (NO+NO2), Low SO2, and CxHy hydrocarbons to help ships achieve and confirm compliance with MARPOL AnnexVI and the NOx Technical Code.
The KIT is equipped with:•�02,�Low�CO,�Low�NO,�Low�NO2,�SO2�����electrochemical sensors•�Special�NDIR�bench�for�CO2�%�and��������������������������CH4 ppm•�Heated�sampling�line�to�provide������������������������������������accurate NO2 and SO2 readings
Bluetooth® connectivity and new mobile app.The�standard�bluetooth®�allows�for�real time data transfer to a PC or to an android base smart mobile device. The new free application speeds up your testing, keeps you away from dirty and noisy rooms and ensures data collection. There is no need anymore for long sampling lines or to stay close to the sampling points. Just enjoy the analyser readings from a more convenient location.
RASI 700 Industrial Flue Gas and Emissions Analyser
The smallest hand held industrial flue gas emissions and gas analyser available today
The dedicated task menu gives direct access to your application. Simply select your “Task”,�i.e�flue�gas�measurement,�your�measurement�programme,�for�example�“Engine�Emissions “ and analyser is ready to operate.Up to 4 measurements programme can be configured with the desire settings such as O2% reference, fuel, practical order of the display measurements.
Select a Task Select an Application Start Measuring
Simplified operation with the Intuitive Task Menu
Save Data
RASI 700 for BIOGAS and CHP’s enginesRASI 700 is also available as sa eparate BIOGAS analyser for O2, CH4, CO2 and H2S or as a combined unit for measuring NOx and CO measurements from the exhaust gas engine.
NDIR sensor for HC and CO2% stack emissionsNew developed dual NDIR bench for direct CO2% measurement ( instead of calculated) and HC in ppm value.NDIR technology for HC offer a much wider scope of applications compared to the traditional Pellistor type sensor as it does not require a minimum O2 level to function.
8 Gas Hand Held AnalyserThis powerful industrial hand held unit can be used as a combustion analyser,emissions analyser or Biogas analyser.Up to 8 measurement sensors can be installed at the same.
Measurements Capabilities
•O2�LL •CO •Low�CO
•NO •NO2 •NOx
•Low�NO •CO% •SO2
•CH4�% •CO2%�NDIR •HC�NDIR
•Smoke •Flow •Pressure
•Temperature •Draught Smoke
Features
Standard Option
Maximum 8 gases ( not all configurations are possible)
O2 sensor •
CO, NO, NO2, SO2, H2S, CO2%. HC, CH4% •
CO sensor protection( mandatory if high and low CO is installed) •
Large integrated and removable water trap •
Pressure, draught, temperature measurement •
Flow and Gas Velocity •
Bluetooth, SD card, USB, IRDA and manual logging •
Auto data logging function •
Fine draught 0.1 pa resolution for BIOMASS boiler testing •
Sampling probes •
Fast IRDA Printer ( external) •
•Connect•Start�measuring•Stop�pump•Save�data•Email�data�
Key Features
IRDA fast printerOur fast IRDA printer prints data faster than any other model available on the market. No feeding is required and changing paper rolls takes a matter of seconds. The print out header can be customised�to�reflect�customer�details,�such as company name, contact name and telephone number.
RASI 700 Industrial Flue Gas and Emissions Analyser
SpecificationsRange Accuracy Resolution Sensor Type
02 0-25 % ± 0.2% Vol abs 0.1% Vol EC
CO(H2 compensated) 0-10000 ppm ± 10 ppm or ± 5% rdg up to 4,000 ppm ± 10 % rdg from 4,000 to 10,000 ppm 1 ppm EC
CO 0-20000 ppm ± 100 ppm or ± 5% rdg up to 4,000 ppm ± 5 % rdg from 4,000 to 20,000 ppm 1 ppm EC
CO % 0-10% ± 0.02% of rdg up to 4 % ± 10% of rdg up to 4 % to 10 % 0.01% EC
Low CO(H2 compensated) 0-300 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC
NO 0-5000 ppm ± 5 ppm or ± 5% rdg up to 1,000 ppm ± 10 % rdg from 1,000 to 5,000 ppm 1 ppm EC
Low NO 0-500 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC
NO2 0-1000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 1,000 ppm 1 ppm EC
SO2 0-5000 ppm ± 10 ppm or 5% rdg up to 2,000 ppm ± 10 % rdg from 2,000 to 5,000 ppm 1 ppm EC
H2S 0-2500 ppm ± 5 ppm or ± 5% rdg up to 50 ppm ± 10 % rdg above 50 ppm 1 ppm EC
1 GAS NDIR BENCH for emissions measurement
CO2 % 0-40 % ± 0.3% vol or ± 5% rdg 0.01% Vol NDIR
2 GAS NDIR Bench for emissions measurement
CO2% 0-40 % ± 0.5% vol or ± 3% rdg 0.01% Vol NDIR
HC 0-40.000 ppm ± 100 ppm 100 ppm NDIR
2 GAS NDIR Bench for Gas Measurement
CH4 0-100 % ± 30 ppm or ± 3% rdg 0.01 % NDIR
CO2 0-100 % ± 30 ppm or ± 3% rdg 0.01% NDIR
Temperature and Pressure
Gas Temperature -50-1700 °C ± 2 °C 0.1 °C TC type K/S
Air Temperature -50 °C to 100 °C ± 1 °C 0.1 °C TC Type K
Draught/Diff Pressure -100 to 100 hPa ± 0,02 hPa 0.01 hPa Piezoresistive
Flow Velocity 3 to 100 m/sec ± 1 m/sec or ± 3 % of rdg 0.1 m/sec Pitot Tube
Calculations
Efficiency 0 to 120 % 0.1 % Calculated
Air Ratio 1 to 9.99 0.01 Calculated
Excess Air 0 to 99,9% 0.1% Calculated
Heat losses 0 to 99.9 % 0.1% Calculated
CO2% ( when CO2% NDIR not installed 0 to CO2% max ± 0.3% vol 0.1% Calculated
Fuel Selection Most common fuels plus user definable
Emissions Calculations Oxygen normalization, automatic conversion ppm, mg/m3 for all toxic gas
Memory, data capture and communication
Storage medium 16000 logs on internal memory, 2GB on standard SD card, Data export to CSV file from SD card
Digital communications USB,�Bluetooth®
General
Gas Sample Preparation Integrated replaceable water trap
Display 3.5 “TFT colour display, 6 lines, full graphic
Weight, Dimension ( W x L x H) 750 g, 110x225x52 mm
IP protection IP21
Power/Mains Ni-Mh Internal rechargeable batteries, OPtional LI-ION , AC 100-250 VAC, 47-63 Hz
Operating/Storage Temperature 5 to 45 °C / -20 to 50 °C
Warranty 2 years instruments 1 year CO, NO,NO2,SO2,H2S, cells, 2 years O2 cell, 2 years NDIR
RASI 700 Industrial Flue Gas and Emissions Analyser
Online View Software
Supplied as standard with the analyser, this power full software allow you to view data in real time on a laptop or PC.Data are displayed in TEXT, GRAPHICAL or BAR format. The software automatically saves and creates an excel file of the measurement taken. Communication is established via blue tooth or USB port.
Data Management
Save time and ensure traceability. Simply upload your sites and log measurement values under each site:Our new concept include:•Site�Administration•Data�administration•Data�Export�on�SD�card•Automatic�data�logging
How to order
to make your selection please state the following:•�Gas�to�be�measured�(�the�analyser�comes standard with O2 cell only) •�Maximum�6�electrochemical�cells�and�one NDIR bench can be installed at the same time•Probe�length�•Temperature�of�the�stack
When selecting your analyser, please consider a few important factors:
•�True�NOx�require�both�NO�and�NO2�����������������������measurement cells installed. Most of industrial application will require NO2 cell installed to provide correct NOx reading•�CO2�%�calculated�values�which�are�fuel dependant can be very erratic. Your application might require an NDIR infrared sensor ( ie stack emissions, CHP engines, Cement plants)
Eiuk offer a large selection of gas sampling probes to match your application. All our probes are supplied with a special Viton line to eliminate sample absorption and to increase the analyser response time. A choice or standard or industrial probes is outlined below.
Standard Gas Sampling Probe
The standard sampling probe is available in different lengths and different materials. It comes complete with integrated thermocouple for temperature readings and positioning cone. More that one probe shaft can be ordered.
Probe Shaft Stainless Steel: Tmax 850 °Clengths: 360, 500, 750 mm, 1m,1.5m, 2 m
Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5 and 2m
Special Hose for gas sampling and con-tinuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7 or 5 mt
Gas Sampling Probes
Engine Probe
The engine probe is specifically designed for sampling on gas or diesel CHP engines: It features
•�Special�Viton�hose�for�maximum�NO2�accuracy•Temperature�measurement•Back�Pressure�measurements•Special�positioning�cone�spring�loaded
Probe Shaft Stainless Steel: Tmax 1200 °Clengths: 360, 500,
Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7
RASI 700 Engine Exhaust Gas analyser
The RASI700 engine Kit is the ideal tool for service and commissioning engineers working on CHP stationary engines. The Kits comes with all the accessories to operate, and it is installed with:•O2,�CO,�NO�and�NO2�cells•Engine�sampling�probe•�Read�in�ppm�and�mg/m3�with�O2�����������������������������reference•IRDA�printer•Blue�Tooth•Carrying�CaseAdds on:•�CO2%,�CH4%�ad�H2S�measurement�for�gas sample.
Eurotron instruments (UK) ltd.Unit 18 Austin WayRoyal Oak Industrial EstateDaventryNorthantsNN11 8QTEnglandT: +44 (0) 1327 871044F: +44 (0) 1327 301255
Service and Support
We are proud of our level of service that we provide to our customers. We can state with confidence that our service turnaround for portable emission testers is no longer than 2 days.
Service & Repair are 100% handled in our ISO 9001:2008 accredited lab in Daventry.
For fixed installation we offer various level of service contracts which are discussed on a case-by-case basis to match our customers expectations.
Test Equipment
EiUK is also a market leader manufacturer for:•� �Temperature�and�Pressure�Calibrators�
for engine maintenance•��Pressure�sensors•��Hand�held�Pressure�Indicator�for�gas�� measurements
Emissions & calibration instruments
Related Products
Data subjected to alteration without notice. Pub ID AQE2015.V02Printed in the U.K, 04/15