![Page 1: PowerPoint Presentationgansystems.com/.../GSDN001-Double-Pulse-Test-GS-065... · The Double Pulse Test (DPT) is used to characterize the turn-on and turn-off characteristics of switching](https://reader033.vdocuments.net/reader033/viewer/2022050603/5faaafcef45ac90ab329dc5e/html5/thumbnails/1.jpg)
GaN Systems – Confidential – 1
GSDN001Double Pulse Test Results for the GS-065-0xx-1-L PDFNs
December 2018
![Page 2: PowerPoint Presentationgansystems.com/.../GSDN001-Double-Pulse-Test-GS-065... · The Double Pulse Test (DPT) is used to characterize the turn-on and turn-off characteristics of switching](https://reader033.vdocuments.net/reader033/viewer/2022050603/5faaafcef45ac90ab329dc5e/html5/thumbnails/2.jpg)
GaN Systems – Confidential – 2
Introduction
PURPOSEThe Double Pulse Test (DPT) is used to characterize the turn-onand turn-off characteristics of switching power transistors.
CONTENTThis document provides the following information• An overview of the DPT set up • DPT results for GaN Systems’ PDFN E-HEMTS
• GS-065-004-1-L• GS-065-008-1-L • GS-065-011-1-L
![Page 3: PowerPoint Presentationgansystems.com/.../GSDN001-Double-Pulse-Test-GS-065... · The Double Pulse Test (DPT) is used to characterize the turn-on and turn-off characteristics of switching](https://reader033.vdocuments.net/reader033/viewer/2022050603/5faaafcef45ac90ab329dc5e/html5/thumbnails/3.jpg)
GaN Systems – Confidential – 3
Double Pulse Test Overview
![Page 4: PowerPoint Presentationgansystems.com/.../GSDN001-Double-Pulse-Test-GS-065... · The Double Pulse Test (DPT) is used to characterize the turn-on and turn-off characteristics of switching](https://reader033.vdocuments.net/reader033/viewer/2022050603/5faaafcef45ac90ab329dc5e/html5/thumbnails/4.jpg)
GaN Systems – Confidential – 4
GS-065-004-1-L: Double Pulse Test at 3.5A
400V DPT at IL= 3.5A
VGS
VDS
IIND
400V
VGS
VDS
IDS
Turn-on
VGS
VDS
IDS
Turn-off
400V
3.5A3.5A
6V6V
GS-065-004-1-L
Parameter Value
VDS 650 V
ID 3.5 A
RDS(on) 500 mΩ
![Page 5: PowerPoint Presentationgansystems.com/.../GSDN001-Double-Pulse-Test-GS-065... · The Double Pulse Test (DPT) is used to characterize the turn-on and turn-off characteristics of switching](https://reader033.vdocuments.net/reader033/viewer/2022050603/5faaafcef45ac90ab329dc5e/html5/thumbnails/5.jpg)
GaN Systems – Confidential – 5
GS-065-008-1-L: Double Pulse Test at 8A
400V DPT at IL = 8A
VGS
VDS
IIND
VGS
VDS
IDS
VGS
VDS
IDS
Turn-on Turn-off
400V400V
8A
8A
6V6V
GS-065-008-1-L
Parameter Value
VDS 650 V
ID 8 A
RDS(on) 225 mΩ
![Page 6: PowerPoint Presentationgansystems.com/.../GSDN001-Double-Pulse-Test-GS-065... · The Double Pulse Test (DPT) is used to characterize the turn-on and turn-off characteristics of switching](https://reader033.vdocuments.net/reader033/viewer/2022050603/5faaafcef45ac90ab329dc5e/html5/thumbnails/6.jpg)
GaN Systems – Confidential – 6
GS-065-011-1-L: Double Pulse Test at 11A
400V DPT at IL = 11A
VGS
VDS
IIND
VGS
VDS
IDS
VGS
VDS
IDS
Turn-on Turn-off
400V
400V
8A8A
6V6V
GS-065-011-1-L
Parameter Value
VDS 650 V
ID 11 A
RDS(on) 125 mΩ
![Page 7: PowerPoint Presentationgansystems.com/.../GSDN001-Double-Pulse-Test-GS-065... · The Double Pulse Test (DPT) is used to characterize the turn-on and turn-off characteristics of switching](https://reader033.vdocuments.net/reader033/viewer/2022050603/5faaafcef45ac90ab329dc5e/html5/thumbnails/7.jpg)
GaN Systems – Confidential – 7
Summary
The DPT results were provided for GaN Systems’ GS-065-004-1-L, GS-065-008-1-L and GS-065-011-1-L E-HEMTs.
To contact GaN Systems for additional product and application support, please visit our website at https://gansystems.com/contact/.