Transcript
Page 1: R410A DC Inverter VRF Series 60Hz-YONAN

Contents05

10

23

35

45

53

63

89

115

119

Overview

V4 Plus Series

V4 Plus S Series

V4 Plus R Series

V4 Plus W Series

Full DC Inverter Mini VRF

Indoor Units Lineup

Control System

HRV

Branch Pipe

V4 Plus series (Heat pump,Cooling only & Corrosion resistance type)

V4 Plus S series

V4 Plus R series

V4 Plus W series

Full DC Inverter Mini VRF

8 10 12 14 16HP

0.822.52Wk 33.5 0.540.04

005,351005,631003,411005,59000,68h/utB

CapacityRange

Appearance

HP

kW

Btu/h

3

10.5

35,830

3.2

12.0

40,950

5

14.0

47,770

6

16.0

54,600

6.5

18.0

61,420

CapacityRange

Appearance

HP

kW

Btu/h

8

25.2

86,000

10

28.0

95,500

12

33.5

114,300

CapacityRange

Appearance

Products Lineup

Indoor Units Lineup

Indoor Units Lineup

Overview

Overview

HR

V

HR

V

Control S

ystem

Control S

ystem

Accessories

Accessories

V4 P

lus S S

eries

V4 P

lus S S

eries

V4 P

lus Series

V4 P

lus Series

V4 P

lus R S

eries

V4 P

lus R S

eries

V4 P

lus W S

eries

V4 P

lus W S

eries

Full DC

Inverter M

ini VR

F

Full DC

Inverter M

ini VR

F

136,500

21018 14 16HP

0.045.330.822.52Wk 45.0

005,59000,68h/utB 114,300 136,500 153,500

CapacityRange

Appearance

114,300

18HP

kW 50.0

Btu/h

8

25.2

86,000

10

28.0

95,500

12

33.5

114,300

14

40.0

006,071005,631

16

45.0

153,500

CapacityRange

Appearance

136,500

Page 2: R410A DC Inverter VRF Series 60Hz-YONAN

Adopting the 180° Sine Wave Inverter to smooth motor rotation greatly improves operating efficiency compared with traditional sawtooth wave.

Smooth 180° sine wave DC inverter

Common Sawtooth Wave 180° Sine Wave DC Inverter

Compressor efficiency

Eff

icie

ncy

-Ro

tor

Sp

eed

Cu

rve

New DC motor-centralized winding

Common DC motor-distributing winding

20 40 60 80 100Rotor speed(s-1)

High efficiency DC inverter compressor

Centralizing winding

Distributing winding

New structure enhances mid-frequency performanceSpecially designed scroll profile for R410A

More compact, weight reduced by 50%

Advanced permanent magnet DC motor improves low-frequency band performance

Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume.

Midea VRF Air Conditioner achieves the industry's top class energy efficiency of cooling EER and heating COP by utilizing the Brushless Reluctance DC compressor control, improved performance heat exchanger by innovative design and numerous high performance key parts. High efficiency DC inverter compressor reduces power consumption by 25%.

OverviewMidea VRF Air Conditioner has a number of key technologies which improve performance and save energy.Here are the main technologies which create the perfect cooling/heating performance, enhance comfort andreliability and easy installation.

Overview

Overview

Page 3: R410A DC Inverter VRF Series 60Hz-YONAN

5 stage oil control technology ensures every outdoorunit & compressor’s oil always keep in the safe level,completely solve the compressor oil lack problem.1st stage: compressor internal oil separate2nd stage: high efficiency oil separator (separationefficiency up to 99%)3rd stage: oil balance technology between compressors4th stage: oil balance technology between modules5th stage: intelligent system oil return program

1st stage

2nd stage

3rd stage

4th stage

5th stage

Precise oil control technology

Cycle duty operation

Backup operation

In one combination, any of the outdoor unit can run as the master unit and master unit can cycle in a period, to realize the equal lifespan among the outdoor units. As a result extend the system lifespan significantly.

In a multiple system, if one module is failed, other modules can be backup instead of the failed one for continuing operation.

ytiroirPytiroirP

ytiroirPytiroirP

Running state

Stand by state

Fault or stop state

Start backup operation

Optimized fan blade shape with new air outlet grille enhanced air flow volume which greatly improves fan performance and decreases noise.Also, a higher external static pressure has been achieved up to 40Pa. (0-20Pa is standard, 20~40Pa should be customized.)

A new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow resistance.

Optimized fan grille

New profile fan blade

Multi solenoid valves control technology

Multi solenoid valves control technology in one system. All the solenoid valves equipped in the unit ensure temperature-control precisely, system running steadily and economic to provide a comfortable environment.

DC motor

High efficiency DC fan motorAccording to the running load and system pressure, the system controls the speed of DC fan to achieve the minimum energy consumption and best performance.

Mot

or s

peed

(RP

M)

System pressure

DC inverter stepless adjustment

AC inverter multistep adjustment

Overview

Overview

Page 4: R410A DC Inverter VRF Series 60Hz-YONAN

V4 P

lus Series

V4 P

lus Series

V4 PLUS SeriesDeveloped to facilitate more flexible system design for big-sized and high-rise buildingsV4 PLUS SERIES VRF product, which is designed to optimize the system and better satisfying the market. Offering a higher capacity up to 64HP by combining maximum four outdoor units, in 2HP as an increment. Three types of units are included: V4 Plus Heat Pump Units (V4+), V4 Plus Corrosion Resistance Heat Pump Units (V4+CR) and V4 Plus Cooling Only Units (V4+C).

- V4 Plus, V4 Plus CR, V4 Plus C

Compact design for effective use of space

Compact size and light weight design minimizes the installation footprint, reduces the installation floor load, and is easier for transportation. For some projects the units can even be transported through the elevator or forklift, reduce access problem at the jobsite.

Easy to transport

Intelligent soft start technology

DC inverter compressor soft start function reduces strike to the electric network. This kind of high-performance and low sound scroll compressor operates at a faster rate when starting, reducing start-up time. It also helps the unit to quickly adjust the room temperature to the set level.

By utilizing the benefits of the inverter compressor, the system can reach full load quickly and shorten the warm-up and cool-down times to provide an immediate and comfortable air solution.Less temperature fluctuation will create a better living environment.

Quick warm-up & cool-down design

2

Fluctuation of room temperature

Cooling operation

1

Double EXV control technology

Double EXV Control Technology in one system, each EXV part achieves 480 pulse to adjust flow precisely. Ensure the temperature-control precisely and steadily to provide a comfortable envrionment.

600

500

400

300

200

100

Starting current(%)

1 2 3 4 5 6

Comparison of start by inverter and bytraditional methods

Direct startY-△ startStart by inverter

(Sec)

Page 5: R410A DC Inverter VRF Series 60Hz-YONAN

FeaturesWide Application Range

The outdoor units capacity range from 8HP up to 64HP in 2HP increment. Maximum 64 indoor units with capacity up to 130% of total outdoor units can be connected in one refrigeration system.

The large quantity of connectable units is suitable for large buildings and projects.

18, 20, 22, 2 4, 26, 28, 30, 32HP

50, 52, 54, 56, 58, 60, 62, 64HP34, 36, 38, 40, 42, 44, 46, 48HP

8, 10HP 12, 14, 16HP

Large connectable indoor units quantity

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27°C(80.6°F) DB/19°C(66.2°F) WB; Outdoor temperature 35°C(95°F) DB/24°C(75.2°F) WBHeating: Indoor temperature 20°C(68°F) DB/15°C(59°F) WB; Outdoor temperature 7°C(44.6°F) DB/6°C(42.8°F) WBPiping length: Interconnecting piping length is 7.5m(24.6ft), level difference is zero.The above combination models are factory-recommended models.

Recommended combination table

Wide range of outdoor unitsh/utBkWkh/utBkWkPH61PH41PH21PH01PH8

1.29720.682.5231121PH8

5.7015.135.598261121PH01

0.8215.733.4115.3361121PH21

5.351545.6310461131PH41

6.071055.3515402131PH61

6.9915.855.1812.35021142PH81

0.512361.1916542242PH02

4.532968.9025.16421142PH22

0.1625.670.23286821152PH42

1.8725.181.94237821152PH62

1.703090.3720882262PH82

1.423590.09258231162PH03

2.1430011.7030923262PH23

5.8638016.72369631273PH43

6.5833116.443101631273PH63

0.6049114.3635.6016311173PH83

6.1345.6216.5833112411183PH04

6.0645314.90402124393PH24

7.7740415.624521241293PH44

7.4945416.344031842193PH64

8.1150516.06453184393PH84

8.0455.8516.8842.34145211014PH05

2.6553612.8946414522014PH25

6.6759619.6155.15145211014PH45

2.2065.6711.93585185211114PH65

2.1365810.3655618513214PH85

3.8460910.0850718522214PH06

3.5665911.7955714631214PH26

4.2860022.416081464214PH46

Capacity

Cooling HeatingModel

N of

Outdoor

Units

No

o

of

Compressors

Outdoor Unit CombinationMaximum N

of Connectable

Indoor Units

o

8HP

10HP

12HP

14HP

16HP

18HP

20HP

22HP

24HP

26HP

28HP

30HP

32HP

34HP

36HP

38HP

40HP

42HP

44HP

46HP

48HP

50HP

52HP

54HP

56HP

58HP

60HP

62HP

64HP

1316 16 16

20 2024 24

28 28 28 32 3236 36 36

42 42 42

48 4854 54 54

58 58 58

64 64

05

10152025303540455055606570

V4 P

lus Series

V4 P

lus Series

Page 6: R410A DC Inverter VRF Series 60Hz-YONAN

*V4 Plus C system is without heating COP value

*POCREE

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

8HP 10HP 12HP 14HP 16HP

4.293.89

3.73.25 3.21

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

8HP 10HP 12HP 14HP 16HP

4.394.14 4.17 4.02 3.91

Outdoor Temperature

0 1 0 2 0 3 0 4 0 50-1 0-2 0

COOLING MODE

HEATING MODE*

Outdoor temperature (DB)

48°C

24°C-20°C

-5°C(23°F) (118.4°F)

(-4°F)

(-4°F) (14°F) (32°F) (50°F) (68°F) (86°F) (104°F) (122°F)

(75.2°F)

Outdoor Temperature

The V4+ series system operates stably at extreme temperatures ranging from -20°C(-4°F) to 48°C(118.4°F).*V4 Plus C system is without HEATING MODE.

*Total piping length is equal to gas pipe or liquid pipe length.*Level difference above 50m are not supported by default but are available on request for customized.

Permitted value

Piping length

Level difference

Outdoor unit up

Outdoor unit down

Actual length

Equivalent length

30HP

>30HP

40m

(131

.2ft.

)

Long

est a

ctua

l pip

ing

leng

th 1

50m

(492

ft.)

Leve

l diff

eren

ce

betw

een

IDU

-IDU

is 1

5m(4

9.2f

t.)

Leve

l diff

eren

ce b

etw

een

IDU

-OD

U is

70m

(229

.6ft.

)*

60Pa

Wide operation range

Long piping length

Total piping length*(Actual)

Longest piping

Equivalent piping length from the farthest IDU to the first indoor branch joint

Level difference between IDU~ODU

Level difference between IDU~IDU

350

500

150

175

40

70*

70

15

m ft.

1148

1640

492

574

131.2

229.6

229.6

49.2

High external static pressure

Max. 60Pa(0.24”W.G.) external static pressure can be customized for the outdoor unit, flexible to build-in installation.

A standard 0-20Pa(0-0.08”W.G.) external static pressure is equipped by default for all outdoor units. 0-40Pa(0-0.16”W.G.) external static pressure can be customized for 8, 10, 14, 16HP outdoor units, and 0-60Pa(0-24”W.G.) can be customized for 12HP outdoor unit.

High EfficiencyHigh COP/EER valuesThe cooling EER up to 4.29 and the heating COP up to 4.39 in the 8HP catagory.

00

0.2 0.4 0.6 0.8 1

0.2

0.4

0.6

0.8

New design

Original design

Frost contrast

Relative frosting rate

Rel

ativ

e w

inda

ge re

sist

ance

Reduce 28%

Reduce 30%

00

200 400 600 800 1000 Re

0.2

0.4

0.6

0.8

New design

Original design

Rel

ativ

e w

inda

ge re

sist

ance

New design Original design

High efficiency inner-threaded pipe, enhance heat transfer.

Reduce air resistance.

Hydrophilic film fins + inner-threaded pipes

The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more power and enhance heat exchange performance.Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.

Windage& air flow

High performance heat exchanger

V4 P

lus Series

V4 P

lus Series

Page 7: R410A DC Inverter VRF Series 60Hz-YONAN

Enhanced Comfort

High comfort outdoor unit’s multi-choice of silent mode during the night.Super silent operation mode can reduce sound level further, minimum 46.8dB (A).

Centralized controller (CCM03 or CCM30) can be connected from indoor side or outdoor side (XYE terminals) at will. Only one group of communication wire of PQE, achieved both of communication for indoor & outdoor unit. It’s more convenient for communication wiring.

-Mode 1 X: 6 hours, Y: 10 hours -Mode 2 X: 8 hours, Y: 10 hours-Mode 3 X: 6 hours, Y: 12 hours -Mode 4 X: 8 hours, Y: 8 hours

*V4 Plus C system is without this function.

noise

Notes: This function can be activated by setting at site. Temperature(load) curve shown in the graph is just an example.

08:00

100

50

00:8000:2200:41

Peak value of ambient temp.

No

ise

dB

Lo

ad %

Cap

acit

y %

8hrs 10hrs

Night silent Mode

Max.-10dB(10Hp)

8hrs 10hrs

Night silent Mode

Max.-10dB(10Hp)

EndStart EndStart

Intelligent defrosting program will judge the defrosting time according to the system real requirement, reduce the heating loss by unnecessary defrosting and make the indoor side more comfortable. Defrosting time can be shortened to 4 min. due to the specialized defrosting valve. H

eatin

g ca

paci

ty

Usual defrosting

t

Time

t min

Intelligent defrosting

Easier Installation and ServiceSimple signal line connection

Auto addressing

Intelligent defrosting technology*

Night silent operation mode

P Q EX Y E X Y E

P Q E P Q E P Q E P Q E

Night silent operation will be

activated X hours after the peak

temperature during daytime,

and it will go back to normal

operation after Y hours.

Outdoor unit can distribute addresses for indoor unit automatically.Wireless and wired controllers can query and modify each indoor unit's address.

SpecificationsV4 Plus Heat Pump Unit (380~415V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

V4 P

lus Series

V4 P

lus Series

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

Ibs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

Power supply

Cooling

Heating

Connectable

indoor unit

Sound pressure level

Pipe

connections

Fan motor

DC inverter

compressor

Fixed scroll

compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating

temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

Model YDV-252(8)W/DCN1(B)

YDV-280(10)W/DCN1(B)

YDV-335(12)W/DCN1(B)

YDV-400(14)W/DCN1(B)

YDV-450(16)W/DCN1(B)

25.2

7.2

86.0

21,672

5.87

4.29

27

7.7

92.1

23,220

6.15

4.39

50-130

13

57

1/2( 12.7)

7/8( 22.2)

1/4( 6)

28

8

95.5

24,080

7.2

3.89

31.5

8.9

107.5

27,090

7.61

4.14

50-130

16

57

1/2( 12.7)

1( 25.4)

1/4( 6)

DC

1

11,700

6,880

420

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

22.1(10)

4.4/2.6

638/377

37-25/32×63-9/16×30-1/8

960×1615×765

40-3/8×70-1/2×32-11/16

1025×1790×830

560(245)

573(260)

33.5

9.5

114.3

28,810

9.05

3.7

37.5

10.7

128.0

32,250

8.99

4.17

50-130

16

59

1/2( 12.7)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.24(20~60) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

26.5(12)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

607(275)

651(295)

40

11.4

136.5

34,400

12.31

3.25

45

12.8

153.5

38,700

11.19

4.02

50-130

16

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

45

12.8

153.5

38,700

14.02

3.21

50

14.2

170.6

43,000

12.79

3.91

50-130

20

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

2

18.55×2

63.3×2

27.6×2

FVC68D

0.13(500)×2

R410A

33.1(15)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

717(325)

761(345)23~118.4(-5~48)

-4~75.2(-20~24)

380-415/3/60

Page 8: R410A DC Inverter VRF Series 60Hz-YONAN

*V4 Plus C system is without this function.

SpecificationsV4 Plus Heat Pump Unit (220V-3Ph-60Hz)

SpecificationsV4 Plus Cooling Only Unit (380~415V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

V4 P

lus Series

V4 P

lus Series

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

Ibs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

Power supply

Cooling

Heating

Connectable

indoor unit

Sound pressure level

Pipe

connections

Fan motor

DC inverter

compressor

Fixed scroll

compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating

temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

Model YDV-252(8)W/DDN1(B)

YDV-280(10)W/DDN1(B)

YDV-335(12)W/DDN1(B)

YDV-400(14)W/DDN1(B)

YDV-450(16)W/DDN1(B)

25.2

7.286.0

21,672

5.87

4.29

27

7.7

92.1

23,220

6.15

4.39

50-130

13

57

1/2( 12.7)

7/8( 22.2)

1/4( 6)

28

8

95.5

24,080

7.2

3.89

31.5

8.9

107.5

27,090

7.61

4.14

50-130

16

57

1/2( 12.7)

1( 25.4)

1/4( 6)

DC

1

11,700

6,880

420

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

22.1(10)

4.4/2.6

638/377

37-25/32×63-9/16×30-1/8

960×1615×765

40-3/8×70-1/2×32-11/16

1025×1790×830

560(245)

573(260)

33.5

9.5

114.3

28,810

9.05

3.7

37.5

10.7

128.0

32,250

8.99

4.17

50-130

16

59

1/2( 12.7)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.24(20~60) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

26.5(12)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

607(275)

651(295)

40

11.4

136.5

34,400

12.31

3.25

45

12.8

153.5

38,700

11.19

4.02

50-130

16

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

45

12.8

153.5

38,700

14.02

3.21

50

14.2

170.6

43,000

12.79

3.91

50-130

20

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

218.55×2

63.3×2

27.6×2

FVC68D

0.13(500)×2

R410A

33.1(15)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

717(325)

761(345)23~118.4(-5~48)

-4~75.2(-20~24)

220/3/60

Model YDVC-252(8)W/DCN1(B)

YDVC-280(10)W/DCN1(B)

YDVC-335(12)W/DCN1(B)

YDVC-400(14)W/DCN1(B)

YDVC-450(16)W/DCN1(B)

380-415/3/60V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

Ibs.(kg)

Ibs.(kg)

°F(°C)

Power supply

Cooling

Connectable

indoor unit

Sound pressure level

Pipe

connections

Fan motor

DC inverter

compressor

Fixed scroll

compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating temperature range-cooling

Capacity

Power input

EER

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

25.2

7.2

86.0

21,672

5.87

4.29

50-130

13

57

1/2( 12.7)

7/8( 22.2)

1/4( 6)

28

8

95.5

24,080

7.2

3.89

50-130

16

57

1/2( 12.7)

1( 25.4)

1/4( 6)

DC

1

11,700

6,880

420

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

22.1(10)

4.4/2.6

638/377

37-25/32×63-9/16×30-1/8

960×1615×765

40-3/8×70-1/2×32-11/16

1025×1790×830

560(245)

573(260)

33.5

9.5

114.3

28,810

9.05

3.7

50-130

16

58

1/2( 12.7)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.24(20~60) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

26.5(12)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

607(275)

651(295)

40

11.4

136.5

34,400

12.31

3.25

50-130

16

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

45

12.8

153.5

38,700

14.02

3.21

50-130

20

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

2

18.55×2

63.3×2

27.6×2

FVC68D

0.13(500)×2

R410A

33.1(15)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

717(325)

761(345)

23~118.4(-5~48)

Page 9: R410A DC Inverter VRF Series 60Hz-YONAN

The V4 Plus CR VRF unit adopts special anti-corrosion treatment on the heat exchanger, electronic parts and other components of the unit, which is about 5 times as anti-salt effective as the normal ones, it makes the unit more suitable for the project nearby the sea.

The plastic planting grille protects against salt.All panel parts are corrosion resistant to protect against brine.

Corrosion resistant heat-exchange fins are suitable for seaside areas and areas exposed to acidic substances.

All PCB parts in the unit are coated with double-sided moisture proof paint. The outer side of the control box metal cover is spray-painted.

All screws are anti-rust.

V4 Plus Corrosion Resistance UnitSpecificationsV4 Plus Cooling Only Unit (220V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

V4 P

lus Series

V4 P

lus Series

Model YDVC-252(8)W/DDN1(B)

YDVC-280(10)W/DDN1(B)

YDVC-335(12)W/DDN1(B)

YDVC-400(14)W/DDN1(B)

YDVC-450(16)W/DDN1(B)

220/3/60V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

Ibs.(kg)

Ibs.(kg)

°F(°C)

Power supply

Cooling

Connectable

indoor unit

Sound pressure level

Pipe

connections

Fan motor

DC inverter

compressor

Fixed scroll

compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating temperature range-cooling

Capacity

Power input

EER

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

25.2

7.2

86.0

21,672

5.87

4.29

50-130

13

57

1/2( 12.7)

7/8( 22.2)

1/4( 6)

28

8

95.5

24,080

7.2

3.89

50-130

16

57

1/2( 12.7)

1( 25.4)

1/4( 6)

DC

1

11,700

6,880

420

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

22.1(10)

4.4/2.6

638/377

37-25/32×63-9/16×30-1/8

960×1615×765

40-3/8×70-1/2×32-11/16

1025×1790×830

560(245)

573(260)

33.5

9.5

114.3

28,810

9.05

3.7

50-130

16

58

1/2( 12.7)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.24(20~60) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

26.5(12)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

607(275)

651(295)

40

11.4

136.5

34,400

12.31

3.25

50-130

16

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

45

12.8

153.5

38,700

14.02

3.21

50-130

20

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

2

18.55×2

63.3×2

27.6×2

FVC68D

0.13(500)×2

R410A

33.1(15)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

717(325)

761(345)

23~118.4(-5~48)

Page 10: R410A DC Inverter VRF Series 60Hz-YONAN

R section view

AB

C

6-5/

8(16

8)8-

3/16

(208

)8-

5/8(

220)

Liquid pipe

Gas pipe

Oil balance pipeFor parallel connect the modular units

Cooling only type withoutGauge point

8/10HP

63-9

/16(

1615

)30

-1/8

(765

)

37-25/32(960)

12/14/16HP

49-7/32(1250)

63-9

/16(

1615

)30

-1/8

(765

)

SIZEHP 8/10HP

7-53/64(199)

6-17/64(159)

7-43/64(195)

1/2( 12.7)

1( 25.4)

12/14/16HP

6-21/32(169)

8-15/64(209)

6-21/32(169)

5/8( 15.9)

1-1/4( 31.8)

A

B

C

Liquid pipe

Gas pipe

SpecificationsV4 Plus Corrosion Resistance Unit (220V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

Unit: in.(mm)

Unit: in.(mm)

DimensionsBody dimension

Installation dimension

R: Pipe connection

Screw bolt position

15×23long U-shape hole

8/10HP: 37-51/64(960)12/14/16HP:49-7/32(1250)

8/10HP: 32-43/64(830)12/14/16HP:44-3/32(1120)

28-3

1/32

(736

)

30-1

/8(7

65)

Concrete basementh=7-7/8(200)

25/64(10) Expansion bolt

Rubber shocking proof mat

Solid ground or roofing

7-7/8(200)

V4 P

lus Series

V4 P

lus Series

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

Ibs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

Power supply

Cooling

Heating

Connectable

indoor unit

Sound pressure level

Pipe

connections

Fan motor

DC inverter

compressor

Fixed scroll

compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating

temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

Model YDV-252(8)W/DDN1(B)-CR

YDV-280(10)W/DDN1(B)-CR

YDV-335(12)W/DDN1(B)-CR

YDV-400(14)W/DDN1(B)-CR

YDV-450(16)W/DDN1(B)-CR

25.2

7.2

86.0

21,672

5.87

4.29

27

7.7

92.1

23,220

6.15

4.39

50-130

13

57

1/2( 12.7)

7/8( 22.2)1/4( 6)

28

8

95.5

24,080

7.2

3.89

31.5

8.9

107.5

27,090

7.61

4.14

50-130

16

57

1/2( 12.7)

1( 25.4)

1/4( 6)

DC

1

11,700

6,880

420

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3

27.6

FVC68D

0.13(500)

R410A

22.1(10)

4.4/2.6

638/377

37-25/32×63-9/16×30-1/8

960×1615×765

40-3/8×70-1/2×32-11/16

1025×1790×830

560(245)

573(260)

33.5

9.5

114.3

28,810

9.05

3.7

37.5

10.7

128.0

32,250

8.99

4.17

50-130

16

58

1/2( 12.7)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.24(20~60) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

1

18.55

63.3 27.6

FVC68D

0.13(500)

R410A

26.5(12)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

607(275)

651(295)

40

11.4

136.5

34,400

12.31

3.25

45

12.8

153.5

38,700

11.19

4.02

50-130

16

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

45

12.8

153.5

38,700

14.02

3.21

50

14.2

170.6

43,000

12.79

3.91

50-130

20

60

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

DC

2

15,600

9,173

360×2

0~0.08(0~20) (default)

0.08~0.16(20~40) (customized)

1

11.8

40.3

27.6×2

FVC68D

0.13(500)

2

18.55×2

63.3×2

27.6×2

FVC68D

0.13(500)×2

R410A

33.1(15)

4.4/2.6

638/377

49-7/32×63-9/16×30-1/8

1250×1615×765

51-9/16×70-1/2×32-1/2

1305×1790×820

717(325)

761(345)23~118.4(-5~48)

-4~75.2(-20~24)

220/3/60

Page 11: R410A DC Inverter VRF Series 60Hz-YONAN

V4 P

lus S S

eries

V4 P

lus S S

eries

V4 Plus S outdoor units achieve world’s largest capacity of 72HP with the industry's top class energy efficiency of cooling and heating. It supports an incredible piping length of 1000m and a longer level difference of 110m, making it perfect for big-sized and high-rise buildings for wide application.

V4 PLUS S Series

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27°C(80.6°F) DB/19°C(66.2°F) WB; Outdoor temperature 35°C(95°F) DB/24°C(75.2°F) WBHeating: Indoor temperature 20°C(68°F) DB/15°C(59°F) WB; Outdoor temperature 7°C(44.6°F) DB/6°C(42.8°F) WBPiping length: Interconnecting piping length is 7.5m(24.6ft), level difference is zero.The above combination models are factory-recommended models.*18HP model can be customized.

Recommended combination table

8HP

10HP

12HP

14HP

16HP

18HP

20HP

22HP

24HP

26HP

28HP

30HP

32HP

34HP

36HP

38HP

40HP

42HP

44HP

46HP

48HP

50HP

52HP

54HP

56HP

58HP

60HP

62HP

64HP

66HP

68HP

70HP

72HP

1

1

2

2

2

2

2

3

3

3

4

4

4

4

4

5

5

6

6

6

6

6

6

7

7

8

8

8

8

8

8

8

8

25.2

28

33.5

40

45

53.2

56

61.5

68

73

80

85

90

96

101

106.5

113

120

125

130

135

143.2

146

151.5

158

165

170

175

180

183.5

190

195

200

86.0

95.5

114.3

136.5

153.5

181.5

191.1

209.8

232.0

249.1

273.0

290.0

307.1

327.6

344.6

363.4

385.6

409.4

426.5

443.6

460.6

488.6

498.2

516.9

539.1

563.0

580.0

597.1

614.2

626.1

648.3

665.3

682.4

27

31.5

37.5

45

50

58.5

63

69

76.5

81.5

90

95

100

108

113

119

126.5

135

140

145

150

158.5

163

169

176.5

185

190

195

200

205.5

213

218

224

92.1

107.5

128.0

153.5

170.6

199.6

215.0

235.4

261.0

278.1

307.1

324.1

341.2

368.5

385.6

406.0

431.6

460.6

477.7

494.7

511.8

540.8

556.2

576.6

602.2

631.2

648.3

665.3

682.4

701.2

726.8

743.8

764.3

kW kBtu/h kBtu/hkW

Cooling Heating

Capacity

Model

1

1

1

1

1

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

4

4

4

4

No of Outdoor

Units

No of Compressors

13

16

20

23

26

29

33

36

39

43

46

50

53

56

59

63

64

64

64

64

64

64

64

64

64

64

64

64

64

64

64

64

64

Maximum No of Connectable

Indoor Units

Outdoor Unit Combination

1

1

1

8HP

1

1

2

1

1

1

2

2

1

1

1

2

1

1

10HP

1

1

1

1

1

12HP

1

1

2

1

1

1

3

2

1

1

3

2

1

1

14HP

1

1

1

2

1

1

1

1

2

3

2

2

2

2

1

2

3

4

1

16HP

3

3

3

4

18HP

Page 12: R410A DC Inverter VRF Series 60Hz-YONAN

V4 P

lus S S

eries

V4 P

lus S S

eries

The large quantity of connectable units is suitable for large buildings and projects.

Heating

kBtu/h

FeaturesWide Application Range

Wide range of outdoor unitsThe outdoor units capacity range from 8HP up to 72HP in 2HP increment. Maximum 64 indoor units with capacity up to 130% of total outdoor units can be connected in one refrigeration system.

8, 10HP 12, 14, 16HP 18, 20, 22, 24, 26, 28, 30, 32HP18HP

50, 52, 54, 56, 58, 60, 62, 64HP34,36, 38, 40, 42, 44, 46, 48HP

66, 68, 70, 72HP, , ,

Large connectable indoor units quantity

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

8HP

10HP

12HP

14HP

16HP

18HP

20HP

22HP

24HP

26HP

28HP

30HP

32HP

34HP

36HP

38HP

40HP

42HP

44HP

46HP

48HP

50HP

52HP

54HP

56HP

58HP

60HP

62HP

64HP

66HP

68HP

70HP

72HP

Num

ber o

f con

nect

able

indo

or u

nit

13

20

26

33

39

46

53

59

64

Outdoor Temperature

0 1 0 2 0 3 0 4 0 50-1 0-2 0

COOLING MODE

HEATING MODE*

Outdoor temperature (DB)

48°C

24°C-20°C

-5°C(23°F) (118.4°F)

(-4°F)

(-4°F) (14°F) (32°F) (50°F) (68°F) (86°F) (104°F) (122°F)

(75.2°F)

Outdoor Temperature

The V4+S series system operates stably at extreme temperatures ranging from -20°C(-4°F) to 48°C(118.4°F).

90m

(295

.2ft.

)

Long

est a

ctua

l pip

ing

leng

th 1

75m

(574

ft.)

Leve

l diff

eren

ce

betw

een

IDU

-IDU

is 3

0m(9

8.4f

t.)

Leve

l diff

eren

ce b

etw

een

IDU

-OD

U is

110

m(3

60.8

ft.)

60Pa

Wide operation range

Long piping length

High external static pressure

Max. 60Pa(0.24”W.G.) external static pressure can be customized for the outdoor unit, flexible to build-in installation.

A standard 0-20Pa(0-0.08”W.G.) external static pressure is equipped by default for all outdoor units. 0-40Pa(0-0.16”W.G.) external static pressure can be customized for 8, 10, 14, 16HP outdoor units, and 0-60Pa(0-24”W.G.) can be customized for 12HP outdoor unit.

Permitted value

Piping length

Level difference

Total piping length (Actual)

Longest piping

Equivalent piping length from the farthest IDU to the first indoor branch joint

Level difference between IDU~ODU

Level difference between IDU~IDU

m ft.

Outdoor unit down

Outdoor unit up

Equivalent length

Actual length

1000*

175

200

40/90*

70

110

30

3280*

574

656

131.2/295.2*

229.6

360.8

98.4

*Total pipe length is equal to two times pipe length plus pipe length. *When the piping length from the farthest IDU to the first indoor branch joint is more than 40m(131.2ft.), it needs to meet specific conditions according to the installation part of the technical manual to achieve 90m(295.2ft.).

Page 13: R410A DC Inverter VRF Series 60Hz-YONAN

High COP/EER values

All DC inverter technology

High Efficiency

The cooling EER up to 4.29 and the heating COP up to 4.39 in the 8HP catagory.

All DC inverter compressors make the capacity output better distributed, and always work at 60-120Hz which is the most efficient range. It makes the efficiency more than 30% higher than the normal.

All DC Inverter Compressors

All DC Fan Motors

According to the running load and system pressure, the system controls the speed of DC fan to achieve the minimum energy consumption and best performance.

Mot

or s

peed

(RP

M)

System pressure

DC inverter stepless adjustment

AC inverter multistep adjustment

New structure enhances mid-frequency performanceSpecially designed scroll profile for R410A

More compact, weight reduced by 50%

Advanced permanent magnet DC motor improves the low frequency band performance

POCREE

8HP 10HP 12HP 14HP 16HP 18HP888HHPP 11000HHPP 11222HHPP 1144HHPP 11116666HHHPPP 11888HHPP

4.39 4.17 4.17 4.02 3.91 3.89

8HP 10HP 12HP 14HP 16HP 18HP

4.293.97 3.81

3.54 3.4 3.38

High performance heat exchanger

00

0.2 0.4 0.6 0.8 1

0.2

0.4

0.6

0.8

New design

Original design

Frost contrast

Relative frosting rate

Rel

ativ

e w

inda

ge re

sist

ance

Reduce 28%

Reduce 30%

00

200 400 600 800 1000 Re

0.2

0.4

0.6

0.8

New design

Original design

Rel

ativ

e w

inda

ge re

sist

ance

New design Original design

High efficiency inner-threaded pipe, enhance heat transfer.

Reduce air resistance.

Hydrophilic film fins + inner-threaded pipes

The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more power and enhance heat exchange performance.Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.

Windage& air flow

Innovative designed high efficiency heat exchanger, which can reach up to 12oC(21.6oF) subcooling degree, reduces the system resistance and improves reliability.When the outdoor temperature is 35oC(95oF), the refrigerant can be cooled down to 37.1oC(98.8oF), thus achieving high heat-exchanging efficiency with only 2.1oC(3.8oF) temperature difference.

Gas

Gas

Gas

Liquid

Liquid

Liquid

Gas LiquidGas-Liquid

Increase the hot liquid rate in the condenserImprove the heat-exchange efficiency

Original design

New design

Common Design

Sub-cooling Technology

V4 P

lus S S

eries

V4 P

lus S S

eries

Page 14: R410A DC Inverter VRF Series 60Hz-YONAN

Enhanced Comfort

High comfort outdoor unit’s multi-choice of silent mode during the night.Super silent operation mode can reduce sound level further, minimum 45dB (A).

Centralized controller (CCM03 or CCM30) can be connected from indoor side or outdoor side (XYE terminals) at will. Only one group of communication wire of PQE, achieved both of communication for indoor & outdoor unit. It’s more convenient for communication wiring.

-Mode 1 X: 6 hours, Y: 10 hours -Mode 2 X: 8 hours, Y: 10 hours-Mode 3 X: 6 hours, Y: 12 hours -Mode 4 X: 8 hours, Y: 8 hours

noise

Notes: This function can be activated by setting at site. Temperature(load) curve shown in the graph is just an example.

08:00

100

50

00:8000:2200:41

Peak value of ambient temp.

No

ise

dB

Lo

ad %

Cap

acit

y %

8hrs 10hrs

Night silent Mode

Max.-10dB(10Hp)

8hrs 10hrs

Night silent Mode

Max.-10dB(10Hp)

EndStart EndStart

Intelligent defrosting program will judge the defrosting time according to the system real requirement, reduce the heating loss by unnecessary defrosting and make the indoor side more comfortable. Defrosting time can be shortened to 4 min. due to the specialized defrosting valve.

Hea

ting

capa

city

Usual defrosting

t

Time

t min

Intelligent defrosting

Easier Installation and ServiceSimple signal line connection

Auto addressing

Intelligent defrosting technology

Night silent operation mode

P Q EX Y E X Y E

P Q E P Q E P Q E P Q E

Night silent operation will be

activated X hours after the peak

temperature during daytime,

and it will go back to normal

operation after Y hours.

Outdoor unit can distribute addresses for indoor unit automatically.Wireless and wired controllers can query and modify each indoor unit's address.

V4 P

lus S S

eries

V4 P

lus S S

eries

Power supply

Cooling

Heating

Connectable indoor unit

Sound pressure level

Pipe connections

Fan motor

DC inverter compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

lbs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

380-415/3/60

25.2

7.2

86.0

21,672

5.88

4.29

27

7.7

92

23,220

6.15

4.39

50-130

13

57

380-415/3/60

28.0

8.0

95.5

24,080

7.05

3.97

31.5

9.0

108

27,090

7.554

4.17

50-130

16

57

380-415/3/60

33.5

9.5

114.3

28,810

8.79

3.81

37.5

10.7

128

32,250

8.993

4.17

50-130

20

59

1/2( 12.7)

1( 25.4)

1/4( 6)

DC

1+1

13,000

7,645

560+380

0-0.08(0-20)(default)

0.08~0.24(20-60)(customized)

1+1

31.59+11.80

107.8+40.3

27.6×2×2

FVC68D

0.132(500)+0.132(500)

R410A

26.5(12)

4.4/2.6

640/380

49-7/32×63-9/16×30-1/8

1,250×1,615×765

51-3/8×70-15/32×32-9/32

1,305×1,790×820

634(288)

678(308)

3/8( 9.53)

7/8( 22.2)

1/4( 6)

DC

1

11,242

6,611

750

0-0.08(0-20)(default)

0.08~0.16(20-40)(customized)

1

31.59

107.8

27.6×2

FVC68D

0.132(500)

R410A

22(10)

4.4/2.6

640/380

37-25/32×63-9/16×30-1/8

960×1,615×765

40-3/8×70-1/2×32-11/16

1,025×1,790×830

466(212)

499(227)

23~118.4(-5~48)

-4~75.2(-20~24)

YDV-252(8)W/D2CN1(B) YDV-280(10)W/D2CN1(B) YDV-335(12)W/D2CN1(B)Model

SpecificationsV4 Plus S Series (380~415V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

Page 15: R410A DC Inverter VRF Series 60Hz-YONAN

V4 P

lus S S

eries

V4 P

lus S S

eries

Power supply

Cooling

Heating

Connectable indoor unit

Sound pressure level

Pipe connections

Fan motor

DC inverter compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

lbs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

23~118.4(-5~48)

-4~75.2(-20~24)

YDV-400(14)W/D2CN1(B) YDV-450(16)W/D2CN1(B) YDV-500(18)W/D2CN1(B)Model

380-415/3/60

40.0

11.4

136.5

34,400

11.30

3.54

45.0

12.8

153.5

38,700

11.19

4.02

50-130

23

61

1/2( 12.7)

1( 25.4)

1/4( 6)

380-415/3/60

45.0

12.8

153.5

38,700

13.25

3.40

50.0

14.2

170.6

43,000

12.79

3.91

50-130

26

62

1/2( 12.7)

1-1/8( 28.6)

1/4( 6)

380-415/3/60

50.0

14.2

170.5

43,000

14.79

3.38

56.0

15.9

191.0

48,160

14.40

3.89

50-130

29

62

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

37.5(17)

683(310)

728(330)

DC

1+1

15,620

9,185

560+380

0-0.08(0-20)(default)

0.08~0.16(20-40)(customized)

1+1

31.59+11.80

107.8+40.3

27.6×2×2

FVC68D

0.132(500)+0.132(500)

R410A

33.1(15)

4.4/2.6

640/380

49-7/32×63-9/16×30-1/8

1,250×1,615×765

51-3/8×70-15/32×32-9/32

1,305×1,790×820

634(288)

678(308)

SpecificationsV4 Plus S Series (380~415V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.*18HP model can be customized.

Power supply

Cooling

Heating

Connectable indoor unit

Sound pressure level

Pipe connections

Fan motor

DC inverter compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

lbs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

220/3/60

25.2

7.2

86.0

21,672

5.88

4.29

27

7.7

92

23,220

6.15

4.39

50-130

13

57

220/3/60

28.0

8.0

95.5

24,080

7.05

3.97

31.5

9.0

108

27,090

7.554

4.17

50-130

16

57

220/3/60

33.5

9.5

114.3

28,810

8.79

3.81

37.5

10.7

128

32,250

8.993

4.17

50-130

20

59

1/2( 12.7)

1( 25.4)

1/4( 6)

DC

1+1

13,000

7,645

560+380

0-0.08(0-20)(default)

0.08~0.24(20-60)(customized)

1+1

31.59+11.80

107.8+40.3

27.6×2×2

FVC68D

0.132(500)+0.132(500)

R410A

24.3(11)

4.4/2.6

640/380

49-7/32×63-9/16×30-1/8

1,250×1,615×765

51-3/8×70-15/32×32-9/32

1,305×1,790×820

628(285)

672(305)

3/8( 9.53)

7/8( 22.2)

1/4( 6)

DC

1

11,242

6,611

750

0-0.08(0-20)(default)

0.08~0.16(20-40)(customized)

1

31.59

107.8

27.6×2

FVC68D

0.132(500)

R410A

19.8(9)

4.4/2.6

640/380

37-25/32×63-9/16×30-1/8

960×1,615×765

40-3/8×70-1/2×32-11/16

1,025×1,790×830

445(202)

481(218)

23~118.4(-5~48)

-4~75.2(-20~24)

YDV-252(8)W/D2DN1(B) YDV-280(10)W/D2DN1(B) YDV-335(12)W/D2DN1(B)Model

SpecificationsV4 Plus S Series (220V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

Page 16: R410A DC Inverter VRF Series 60Hz-YONAN

V4 P

lus S S

eries

V4 P

lus S S

eries

8/10 HP

63-9

/16(

1615

)30

-1/8

(765

)

37-25/32(960)

12/14/16 /18 HP

49-7/32(1250)

63-9

/16(

1615

)30

-1/8

(765

)

Unit: in.(mm)

Unit: in.(mm)

DimensionsBody dimension

Installation dimension

Screw bolt position

15×23long U-shape hole

8/10HP: 37-51/64(960)12/14/16HP:49-7/32(1250)

8/10HP: 32-43/64(830)12/14/16HP:44-3/32(1120)

28-3

1/32

(736

)

30-1

/8(7

65)

Concrete basementh=7-7/8(200)

25/64(10) Expansion bolt

Rubber shocking proof mat

Solid ground or roofing

7-7/8(200)

Power supply

Cooling

Heating

Connectable indoor unit

Sound pressure level

Pipe connections

Fan motor

DC inverter compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Oil balance pipe

Type

Quantity

Air flow rate

Motor output

ESP

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

in.(mm)

m3/h

CFM

W

in.WG(Pa)

in.WG(Pa)

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

lbs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

23~118.4(-5~48)

-4~75.2(-20~24)

YDV-400(14)W/D2DN1(B) YDV-450(16)W/D2DN1(B) YDV-500(18)W/D2DN1(B)Model

220/3/60

40.0

11.4

136.5

34,400

11.30

3.54

45.0

12.8

153.5

38,700

11.19

4.02

50-130

23

61

1/2( 12.7)

1( 25.4)

1/4( 6)

220/3/60

45.0

12.8

153.5

38,700

13.25

3.40

50.0

14.2

170.6

43,000

12.79

3.91

50-130

26

62

1/2( 12.7)

1-1/8( 28.6)

1/4( 6)

220/3/60

50.0

14.2

170.5

43,000

14.79

3.38

56.0

15.9

191.0

48,160

14.40

3.89

50-130

29

62

5/8( 15.9)

1-1/8( 28.6)

1/4( 6)

35.2(16)

683(310)

728(330)

DC

1+1

15,620

9,185

560+380

0-0.08(0-20)(default)

0.08~0.16(20-40)(customized)

1+1

31.59+11.80

107.8+40.3

27.6×2×2

FVC68D

0.132(500)+0.132(500)

R410A

28.7(13)

4.4/2.6

640/380

49-7/32×63-9/16×30-1/8

1,250×1,615×765

51-3/8×70-15/32×32-9/32

1,305×1,790×820

628(285)

672(305)

SpecificationsV4 Plus S Series (220V-3Ph-60Hz)

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.*18HP model can be customized.

Page 17: R410A DC Inverter VRF Series 60Hz-YONAN

The all DC inverter V4 Plus heat recovery series, which can offers simultaneous cooling and heating operation in one system. The energy by-product from cooling or heating is transferred to where it is required by using the balanced heat exchanger function, which saves up to 50% in costs compared with a conventional heat pump system.

V4 PLUS R Series

Offers simultaneous cooling and heating operation in one system

Recommended combination table

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27°C(80.6°F) DB/19°C(66.2°F) WB; Outdoor temperature 35°C(95°F) DB/24°C(75.2°F) WBHeating: Indoor temperature 20°C(68°F) DB/15°C(59°F) WB; Outdoor temperature 7°C(44.6°F) DB/6°C(42.8°F) WBPiping length: Interconnecting piping length is 7.5m(24.6ft), level difference is zero.The above combination models are factory-recommended models.

8HP 10HP 12HP 14HP 16HP kW kBtu/h kW kBtu/h

8HP 1.29720.682.5231111

10HP 5.7015.135.598261111

12HP 0.8215.733.4115.3302111

14HP 5.351545.6310432121

16HP 6.071055.3515462121

18HP 5.1812.35921122 58.5 199.6

20HP 0.512361.1916533222

22HP 4.532968.9025.16631122

24HP 2 3 1 1 39 68 232.0 76.5 261.0

26HP 1.8725.181.94237341132

28HP 1.703090.3720864242

30HP 1.423590.09258051142

32HP 2.1430011.7030935242

34HP 3 4 2 1 56 96 327.6 108 368.5

36HP 6.5833116.443101951243

38HP 3 4 1 1 1 63 106.5 363.4 119 406.0

40HP 3 5 1 1 1 64 113 385.6 126.5 431.6

42HP 6.0645314.90402146363

44HP 7.7740415.624521461263

46HP 7.4945416.344031462163

48HP 8.1150516.06453146363

50HP 8.0455.8516.8842.3414621164

52HP 2.6553612.894641462264

54HP 4 6 1 1 2 64 151.5 516.9 169 576.6

56HP 4 7 1 1 2 64 158 539.1 176.5 602.2

58HP 2.1365810.365561461384

60HP 3.8460910.085071462284

62HP 3.5665911.795571463184

64HP 4.2860022.41608146484

Capacity

Cooling HeatingModel

No of

Outdoor

Units

No of

Compressors

Outdoor Unit CombinationMaximum N

o

of Connectable

Indoor Units

V4 P

lus R S

eries

V4 P

lus R S

eries

Page 18: R410A DC Inverter VRF Series 60Hz-YONAN

FeaturesWide Application RangeWide range of outdoor units

Long piping length

8, 10, 12, 14, 16HP

34-48HP

18-32HP

50-64HP

Cooling Mode

Heating Mode

Simultaneous Cooling and Heating Mode

48°C

24°C

24°C-5°C

-20°C

-5°C

Wide operation temperature range

High external static pressure

0 10 20 30 40 50-10-20

The outdoor units’ capacity range from 8HP up to 64HP in 2HP increment. Maximum 64 indoor units with capacity up to 130% of total outdoor units can be connected as one refrigeration system.

Leve

l diff

eren

ce b

etw

een

IDU

~ID

U 3

0m(9

8.4f

t.)

The solution supports an incredible piping length of 1,000m(3280ft.) and level difference of 110m(360.8ft.), making it perfect for large projects.

Permitted value

Total piping length* (Actual)

Longest piping Piping length

Level difference

Level difference between IDU~IDU

Level difference between IDU~ODU

Equivalent piping length from the farthest IDU to the first indoor branch joint

Equivalent piping length from MS to its downstream indoor unit

Outdoor unit up

Outdoor unit down

Actual length

Equivalent length

High COP/EER values

High Efficiency

The cooling EER up to 4.40 and the heating COP up to 4.50 in the 8HP catagory.

8HP 10HP 12HP 14HP 16HP

4.40 4.20 4.15 3.54 3.40

EER

8HP 10HP 12HP 14HP 16HP

4.50 4.30 4.30 4.02 3.91

COP

L i i l th

Leve

l diff

eren

ce b

etw

een

IDU

~ID

U 3

0m(9

8.4f

t.)

90m

(295

.2ft.

)

Long

est a

ctua

l pip

ing

leng

th 1

75m

(574

ft.)

Leve

l diff

eren

ce b

etw

een

IDU

~OD

U 1

10m

(360

.8ft.

)

60 Pa

m ft.

1000

175

200

40/90*

40

70

110

30

3280

574

656

131.2/295.2*

131.2

229.6

360.8

98.4

*Total pipe length is equal to two times pipe length plus pipe length. *When the piping length from the farthest IDU to the first indoor branch joint is more than 40m(131.2ft.), it needs to meet specific conditions according to the installation part of the technical manual to achieve 90m(295.2ft.).

(23°F) (118.4°F)

)F°2.57()F°4-(

(75.2°F)

Outdoor temperature (DB)(-4°F) (14°F) (32°F) (50°F) (68°F) (86°F) (104°F) (122°F)

(23°F)

The V4+R series system operates stably at extreme temperatures ranging from -20°C(-4°F) to 48°C(118.4°F).

Max. 60Pa(0.24”W.G.) external static pressure can be customized for the outdoor unit, flexible to build-in installation.

A standard 0-20Pa(0-0.08”W.G.) external static pressure is equipped by default for all outdoor units. 0-40Pa(0-0.16”W.G.) external static pressure can be customized for 14, 16HP outdoor units, and 0-60Pa(0-24”W.G.) can be customized for 8, 10, 12HP outdoor unit.

V4 P

lus R S

eries

V4 P

lus R S

eries

Page 19: R410A DC Inverter VRF Series 60Hz-YONAN

V4 P

lus R S

eries

V4 P

lus R S

eries

All DC inverter technology

Heat recovery, more efficiency

All DC inverter compressors make the capacity output better distributed, and always work at 60-140Hz which is the most efficient range. It makes the efficiency more than 30% higher than the normal.

New structure enhances mid-frequency performanceSpecially designed scroll profile for R410A

More compact, weight reduced by 50%

Advanced permanent magnet DC motor improves the low frequency band performance

All DC Inverter Compressors

All DC Fan Motors

According to the running load and system pressure, the system controls the speed of DC fan to achieve the minimum energy consumption and best performance.

Mot

or s

peed

(RP

M)

System pressure

DC inverter stepless adjustment

AC inverter multistep adjustment

Simultaneous heating and cooling in different zones, more energy saving by heat recovery from one space to another which saves up to 50% in costs compared with a conventional heat pump system.

2-pipe system 3-pipe system

Simultaneous Cooling and Heating Operation

No power consumptionfor heat recovery

Powerconsumption

CoolingHeating

Heating capacity automatic adjustmentTwo parts condenser individual design, the unit can distribute a part of evaporator to be as condensing areaaccording to the heating load requirement to improve the utilization rate of the condenser.

Cooling14kW

(47.8kBtu/h)14kW

(47.8kBtu/h)14kW

(47.8kBtu/h)14kW

(47.8kBtu/h)14kW

(47.8kBtu/h)14kW

(47.8kBtu/h)

Cooling Cooling Cooling Heating Heating

Partial Using

t th i

Cooling and heating simultaneous

Auto mode control

Continuous heating during defrost operation

Enhanced Comfort

At the auto mode, the indoor unit can change the operation mode, to control the indoor side temperature at aconstant temperature demanded.

Simultaneous cooling and heating achieved for new designed MS (Mode Switch) equipment.

Unit change to cooling mode at daytime,

when indoor temperature is higher than

setting temperature, and change to

heating mode at nighttime, when indoor

temperature is lower than setting temp.

Tem

per

atu

re

Setting temperature Ts Indoor temperature Ti

Ti>TsCooling mode

Ti<TsHeating mode

Mode change automatically

Each heat exchanger is defrosted by using heat transferred from one heat exchanger to the other in the outdoor unit. Defrost has no impact on the indoor unit on heating mode.

Heat Exchanger 1

Heat Exchanger 2

Defrosting heat exchanger 1

Heat

Outdoor Unit

Heat Exchanger 1

Heat Exchanger 2

Defrosting heat exchanger 2

Heat

Outdoor Unit

Heat Exchanger 1

Heat Exchanger 2

Heating

Outdoor Unit

The outdoor unit individual controls the operation mode of each group indoorunit to achieve simultaneous heating and cooling in one system under the MSequipment which adopts solenoid valve to precise control refrigerant flow rate.

The indoor units connect to one MS can realize simultaneous cooling andheating operation.

Max. 4 Indoor Units Max. 4 Indoor Unitscooling heating heatingcooling

Max. 4 Indoor Unitsheating heatingcooling cooling cooling

stinU roodnI 4 .xaMstinU roodnI 4 .xaMheating heating heatingheatingcooling cooling cooling cooling

Page 20: R410A DC Inverter VRF Series 60Hz-YONAN

Easier Installation and ServiceRemote addressing

Simple communication wiring

Professional structure design for easy maintainence

Addressing indoor units are able to be done just by pressing the button of the controller.No need to set the address by the DIP switch one by one.Wired controller and wireless controller can enquire and modify every indoor units address. Remote addressing

Centralized controller (CCM03) can connect from indoor side or outdoor side (XYE terminals) at will. Only one group of communication wire of PQE, achieved both of communication for indoor & outdoor unit and network. It’s more convenient for communication wiring.

E ,Q ,PE ,Q ,PE ,Q ,PE ,Q ,P

H1, H2, E

X, Y, E

P, Q, E

E ,Q ,PE ,Q ,P

Compressor is near the outside, and there is simple pipe system for convenient maintenance.The newly designed rotating control box is so excellent that it can rotate in a wide angle. It is convenient for the inspection and maintenance of the pipeline system and greatly reduced the time of dismount the electric control box.

The check window reserved on electric control box provides a convenient spot checking and status enquiry. With the 4 bits digital tube LED display, it is very convenient to show the data of the system, such as pressure, compressor frequency, error code, discharge temperature etc., which can make the maintenance, installation and commissioning easier.

Outer layout compressor and simple pipe system

Rotating electric control box

Specifications

Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Outdoor temperature 35oC(95oF) DB/24oC(75.2oF) WB.Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Outdoor temperature 7oC(44.6oF) DB/6oC(42.8oF) WB.Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1.3m(4.264ft.) above the floor.

V4+R SeriesYDV-252(8)W/D2RN1T(C)YDV-280(10)W/D2RN1T(C) YDV-335(12)W/D2RN1T(C)YDV-400(14)W/D2RN1T(C) YDV-450(16)W/D2RN1T(C)

V4 P

lus R S

eries

V4 P

lus R S

eries

V/Ph/HzkWRT

kBtu/hkcal/h

kWkW/kW

kWRT

kBtu/hkcal/h

kWkW/kW

%

dB(A)in.(mm)in.(mm)in.(mm)in.(mm)in.(mm)

m3/hCFM

Win.WG(Pa)in.WG(Pa)

kWkBtu/h

W

gal.(ml)

Ibs.(kg)MPaPSIinchmminchmm

Ibs.(kg)Ibs.(kg)°F(°C)°F(°C)°F(°C)

ModelPower supply

Cooling

Heating

Connectable indoor unitSound pressure levelPipe connections

Fan motor

DC inverter compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight Gross weightOperating temperature range

Capacity

Power inputEERCapacity

Power inputCOPTotal capacityMax. quantity

Liquid pipeLow pressure gas pipeHigh pressure gas pipeHigh pressure gas balance pipeOil balance pipeTypeQuantityAir flow rate

Motor outputESP

QuantityCapacity

Crankcase heaterOil typeOil chargeTypeFactory charging

CoolingHeatingSimultaneous Cooling and Heating

25.2 7.2

86.0 21,672

5.734.40 27.0 7.7

92.1 23,220

6.00 4.50

50-1301357

3/8(9.53)7/8(22.2)3/4(19.1)3/4(19.1)

1/4(6)

212,000 7,060

420

561(255)600.6(273)

28.0 8.0

95.5 24,080

6.67 4.20 31.5 8.9

107.5 27,090

7.33 4.30

50-1301657

1/2(12.7)7/8(22.2)3/4(19.1)3/4(19.1)

1/4(6)

212,000 7,060

420

561(255)600.6(273)

33.5 9.5

114.3 28,810

8.07 4.15 37.5 10.7

128.0 32,250

8.72 4.30

50-1302058

1/2(12.7)1(25.4)

3/4(19.1)3/4(19.1)

1/4(6)DC2

13,000 7,650

420

561(255)600.6(273)

40.0 11.4

136.5 34,400 11.30 3.54 45.0 12.8

153.5 38,700 11.19 4.02

50-1302360

5/8(15.9)1-1/8(28.6)7/8(22.2)3/4(19.1)

1/4(6)

215,000 8,830

750

666.6(303)708.4(322)

45.0 12.8

153.5 38,700 13.24 3.40 50.0 14.2

170.6 43,000 12.79 3.91

50-1302660

5/8(15.9)1-1/8(28.6)7/8(22.2)3/4(19.1)

1/4(6)

215,000 8,830

750

666.6(303)708.4(322)

380-415/3/60

YDV-252(8)W/D2RN1T(C)

YDV-280(10)W/D2RN1T(C)

YDV-335(12)W/D2RN1T(C)

YDV-400(14)W/D2RN1T(C)

YDV-450(16)W/D2RN1T(C)

0~0.08(0~20) (default) (0.08~0.24)(20~60) (customized)

131.59107.830×2

FVC68D0.132(500)

R410A22(10)

0~0.08(0~20) (default) (0.08~0.16)(20~40) (customized)

231.59+11.8107.8+40.3

30×4FVC68D

0.132+0.132(500+500)R410A

28.6(13)4.4/2.6

640/38049-7/32×63-9/16×30-1/8

1250×1615×76551-9/16×70-1/2×32-1/2

1305×1790×820

23~118.4(-5~48)-4~75.2(-20~24)23~75.2(-5~24)

Page 21: R410A DC Inverter VRF Series 60Hz-YONAN

Unit: in.(mm)

Unit: in.(mm)

Dimensions-ABody dimension

Installation dimension

R: Pipe connection

9-7/

8(25

0)

8-1/16(205)9-5/8(245)11-7/16(290)

9-1/

16(2

30)

8-1/

16(2

05)

7-7/

8(20

0)

6-11

/16(

170)

R section view

Oil balance pipe

Liquid pipe

High pressure gas pipe

Low pressure gas pipe

High pressuregas balance pipe

SIZE

HP14/168/10 12

Liquid pipe

Low pressure gas pipe

High pressure gas pipe

High pressure gas balance pipe

Oil balance pipe

1/2(12.7)

7/8(22.2)

3/4(19.1)

3/4(19.1)

1/4(6)

5/8(15.9)

1(25.4)

3/4(19.1)

3/4(19.1)

1/4(6)

5/8(15.9)

1-1/8(28.6)

7/8(22.2)

3/4(19.1)

1/4(6)

63-9

/16(

1615

)

49-7/32(1250)

30-1

/8(7

65)

Screw bolt position

15×23long U-shape hole

49-7/32(1250)

44-3/32(1120)

28-3

1/32

(736

)

30-1

/8(7

65)

Concrete basementh=7-7/8(200)

25/64(10) Expansion bolt

Rubber shocking proof mat

Solid ground or roofing

7-7/8(200)

MS SpecificationsMS equipment which can be connected multiple indoor unitsYS02/N1-CYS04/N1-C YS06/N1-C

YS02/N1-C

2

4

4×2=8

16

54.6

28

95.5

1/2(12.7)

3/4(19.1)

1(25.4)

3/8(9.53)

5/8(15.9)

24-3/4×8-7/8×23-5/8

630×225×600

28-9/16×12-3/4×27

725×325×685

42.9(19.5)

59.4(27)

YS04/N1-C

4

4

4×4=16

16

54.6

45

153.5

5/8(15.9)

7/8(22.2)

1-1/4(31.8)

3/8(9.53)

5/8(15.9)

37-13/16×8-7/8×23-5/8

960×225×600

41-1/2×12-3/4×27

1055×325×685

68.2(31)

88(40)

YS06/N1-C

6

4

4×6=24

16

54.6

45k

153.5

5/8(15.9)

7/8(22.2)

1-1/4(31.8)

3/8(9.53)

5/8(15.9)

37-13/16×8-7/8×23-5/8

960×225×600

41-1/2×12-3/4×27

1055×325×685

77(35)

97.9(44.5)

Model

Max. indoor unit groups

Max. number of each group indoor units

Max. number of all downstream indoor units

Net weight

Gross weight

Connect to

outdoor

unit

Connect to

indoor unit

Liquid pipe

High pressure gas pipe

Low pressure gas pipe

Liquid pipe

Gas pipe

kW

kBtu/h

kW

kBtu/h

In.(mm)

In.(mm)

In.(mm)

In.(mm)

In.(mm)

inch

mm

inch

mm

Ibs.(kg)

Ibs.(kg)

Max. capacity of each group indoor units

Total capacity of all downstream indoor units

Net dimension (W×H×D)

Packing size (W×H×D)

MS equipment which can be connected only one indoor unit

YS02E/N1-C YS04E/N1-C

Piping

connections

YS02E/N1-C

1

20~28

68.2~95.5

1/2(12.7)

3/4(19.1)

1(25.4)

3/8(9.53)

5/8(15.9)

24-3/4×8-7/8×23-5/8

630×225×600

28-9/16×12-3/4×27

725×325×685

42.9(19.5)

59.4(27)

YS04E/N1-C

1

40~56

136.5~191.1

5/8(15.9)

7/8(22.2)

1-1/4(31.8)

3/8(9.53)

5/8(15.9)

37-13/16×8-7/8×23-5/8

960×225×600

41-1/2×12-3/4×27

1055×325×685

68.2(31)

88(40)

Model

Max. number of all downstream indoor units

Net weight

Gross weight

Connect to

outdoor

unit

Connect to

indoor unit

Liquid pipe

High pressure gas pipe

Low pressure gas pipe

Liquid pipe

Gas pipe

kW

kBtu/h

In.(mm)

In.(mm)

In.(mm)

In.(mm)

In.(mm)

inch

mm

inch

mm

Ibs.(kg)

Ibs.(kg)

Capacity of downstream indoor unit

Net dimension (W×H×D)

Packing size (W×H×D)

Piping

connections

V4 P

lus R S

eries

V4 P

lus R S

eries

Page 22: R410A DC Inverter VRF Series 60Hz-YONAN

The YONAN V4 Plus W series is the perfect combination of water and refrigerant systems. The main unit achieves the world's largest capacity of 36HP and provide the highest energy efficiency for cooling and heating. The series boasts excellent energy saving features, flexible system design and maximized comfort. In addition to traditional cooling towers / boilers, there are more water source options including river water, soil, solar energy, sea water, lake water, ground water, waste heat from production, sewage or waste water.

V4 PLUS W Series

Water delivery pipe

(Connect with the cooling tower/boiler)

V4+W Series air conditioning system

Refrigerant piping

Connect with indoor unit

Cooling tower

Ground water

Recommended combination table

Cooling Heating

Capacity

ModelNo of

Outdoor Units

No of Compressors

Maximum No of Connectable

Indoor Units

Outdoor Unit Combination

1

1

1

2

2

2

2

2

3

3

3

3

3

3

8HP

10HP

12HP

16HP

18HP

20HP

22HP

24HP

26HP

28HP

30HP

32HP

34HP

36HP

1

1

1

2

2

2

2

2

3

3

3

3

3

3

1

2

1

2

1

1

1

2

1

1

2

3

2

1

1

1

2

1

2

3

13

16

20

26

29

33

36

39

43

46

50

53

56

59

25.2

28

33.5

50.4

53.2

56

61.5

67

78.4

81.2

84

89.5

95

100.5

86.0

95.5

114.3

172.0

181.5

191.1

209.8

228.6

267.5

277.1

286.6

305.4

324.1

342.9

27

31.5

37.5

54

58.5

63

69

75

85.5

90

94.5

100.5

106.5

112.5

92.1

107.5

128.0

184.2

199.6

215.0

235.4

255.9

291.7

307.1

322.4

342.9

363.4

383.9

kW kBtu/h kBtu/hkW8HP 10HP 12HP

Notes: Capacities are based on the following conditions:Cooling: Indoor temperature 27°C(80.6°F) DB/19°C((66.2°F) WB; Main unit ambient temperature 35°C((95°F) DB/24°C((75.2°F) WB; Water inlet temperature 30°C((86°F).Heating: Indoor temperature 20°C((68°F) DB/15°C((59°F) WB; Main unit ambient temperature 7°C(44.6°F) DB/6oC(42.8°F) WB; Water inlet temperature 20°C((68°F).Piping length: Interconnecting piping length is 5m(16.4ft.), level difference is zero.The above model combinations are factory-recommended models.

V4 P

lus W S

eries

V4 P

lus W S

eries

Page 23: R410A DC Inverter VRF Series 60Hz-YONAN

FeaturesThe main units capacity range from 8HP up to 36HP. Maximum 59 indoor units with capacity up to 130% of total main units can be connected in one refrigeration system.

26,28,30,32,34,36HP8, 10,12HP 16, 18, 20,22,24HP

Main unit ambient temperature: 0°C~40°C(32°F-104°F)

Main unit water inlet temperature: 7°C~45°C(44.6°F-113°F)

Indoor temperature:cooling: 17°C~32°C(62.6°F-89.6°F)

Indoor temperature:heating: 15°C~30°C(59°F-86°F)

Main unit water inlet flow: 8HP: 2.7~8.1m³/h; 10HP: 3~9m³/h; 12HP: 3.6~10.8m³/h.

High Reliability

High Efficiency

Climate-resistant units

Due to the stable source of water as the cold/heat source of the system, the air conditioning capacity is not affected by environmental temperature.When heating in winter, the unit does not implement the frost/defrosting process, which stabilizes and strengthens the heating effect.

Long piping length

*The allowable length can extend to 90m(295.3ft) under certain conditions. Please refer to the service manual for details.

Permitted value

Total piping length(Actual)

Piping length

Level differenceMain unit up

Main unit down

50m(164ft)

40m(131.2ft)

30m(98.4ft)

Actual length

Equivalent length

120m(393.7ft)

150m(492.1ft)

40m*(131.2ft)

300m(984.3ft)

(3)

(2)

In the refrigerant piping system, total piping length can extend up to 300m(984.3ft) with a longest piping actual length of 120m(393.7ft) and a level difference between indoor unit and outdoor units of 50m(164ft). The maximum pressure at the water side can be as high as 1.96Mpa (200m(393.7ft) height difference), enabling a flexible design in high-rise buildings.Water piping does not enter occupied spaces, so there is little chance of water leaks.

(1)

3))))))))))))))))(3)3)

(3))

(3)

(3)

(3)3)

(3(3(333)

(2))))2)

(2))))

(2)

(2)))))))2))))

(2))2)2)2))

(2)2)

(2222(2(2222222((

(1))(1)(1)1)(1)(1)(1)(1)(1)11)1)11)(1(1)(1))))((( ))))(

30In

door

uni

t-Ind

oor u

nit

leve

l diff

eren

ce

m(9

8.4f

t)

50M

ain

unit-

Indo

or u

nit

leve

l diff

eren

ce

m*(

164f

t)

120Maximum piping actual length m(393.7ft)

122°F

113°F

104°F

95°F

86°F

77°F

68°F

59°F

50°F

41°F

32°F 32°F

44.6°F

62.6°F59°F

86°F89.6°F

113°F

104°F

Wide Application RangeWide range of outdoor units

Wide operation temperature range

Longest piping

Equivalent piping length from the farthest IDU to the first indoor branch joint

Level difference between IDU~IDU

Level difference between IDU to main unit

No water leakageNo water pipe installed indoors, no water leakage risks.

Refrigerant piping system

Water piping system

YONAN V4 Plus W Series System combines water system and refrigerant system perfectly. IPLV(C) reaches as high as 5.9. Compared with air-cooled VRF, it saves much energy.

High IPLV

8HP 10HP 12HP

5.9 5.8 5.8IPLV(C)5.9

V4 P

lus W S

eries

V4 P

lus W S

eries

Page 24: R410A DC Inverter VRF Series 60Hz-YONAN

Enhanced Comfort Low noiseWithout outdoor units fan noise and fully enclosed design which realize lower noise.

Outdoor heat

exchanger changes4-way reversing valf 4-way reversing valf

Air-cooled

Water-cooledFan

AAAAAAA’’AAAAAAAAAAAAAAAAAAAAAAAA

Modular designThe three basic models, 8,10 and 12HP, are the same size and weight: W780mm×H1000mm×D550mm(W30-45/64in×H39-3/8in×D21-21/32in), 146kg(321.9lbs). The modular design enables one main unit to be installed above another, which greatly saves space.Various installation environments include warehouses, basements, closed balconies, corridors, and factories.

1000

mm

(39-

3/8i

n)

550mm

(21-21/32in)780mm30-45/64in

1000

mm

(39-

3/8i

n)

water

Refrigerant

With the innovative designed double-pipe heat exchanger, the water quality required is low. The water side has large circula-tion area, and it is not easy to get stuck, higher reliability, easy to clean and maintain.

High efficiency double-pipe heat exchanger

Water side heat recovery function

Heat

Cooling

Heating

Conference roomPlant room

The office The office Reception room

In the modern large-scale buildings, the load between the internal and external areas is different. It may occur situations that both cooling and heating are required. The V4 PLUS W series modular design, not only can realize meticulous system division in different areas but also can realize heat recovery at the same time, significantly improved energy efficiency.

A range of available modes can meet a wide variety of user needs.

MORE INTELLIGENTVarious locking modes

Hea ng

priority mode(default)

Cooling priority mode

First onindoor unit

priority mode

Only responds to

hea ng mode

Only responds to

cooling mode

espondso g mode

Only

cool

t onor unity mode

Only

hea

oling y mode

Fiindo

prior

a ng y modeault)

Coprior

espondstog mode

Easy access

The checking window on electric control box for convenient spot checking and status enquiry.

Compressor is located near the door, which simplifies checks and enables valve or compressor parts to be replaced easily.

Thelecoan

EASIER INSTALLATION AND SERVICE

V4 P

lus W S

eries

V4 P

lus W S

eries

Page 25: R410A DC Inverter VRF Series 60Hz-YONAN

30-45/64(780)

21-2

1/32

(550

)39

-3/8

(100

0)12×20 long u-shape hole

25-19/32(650)

30-45/64(780)

20-2

5/64

(518

)

21-2

1/32

(550

)

SpecificationsV4+W SeriesYDVS-252(8)W/DCN1YDVS-280(10)W/DCN1 YDVS-335(12)W/DCN1

Unit: in.(mm)

Unit: in.(mm)

DimensionsBody dimension

Installation dimension

Main unit

Concrete basementh=7-7/8(200)

25/64(10) Expansion bolt

Rubber shocking proof mat

Solid ground or roofing

7-7/8(200)Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC(80.6oF) DB/19oC(66.2oF) WB; Main unit ambient temperature 35oC(95oF) DB/24oC(75.2oF) WB; Water inlet temperature 30oC(86oF).Heating: Indoor temperature 20oC(68oF) DB/15oC(59oF) WB; Main unit ambient temperature 7oC(44.6oF) DB/6oC(42.8oF) WB; Water inlet temperature 20oC(68oF).Piping length: Interconnecting piping length is 5m(16.4ft.), level difference is zero.Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m(295.2ft.). When the total equivalent liquid length is more than 90m(295.2ft.), please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m(3.28ft.) in front of the unit and 1m(3.28ft.) above the floor.

V4 P

lus W S

eries

V4 P

lus W S

eries

Model YDVS-252(8)W/DCN1 YDVS-280(10)W/DCN1 YDVS-335(12)W/DCN1

25.27.2

86.021,672

4.85.2527.07.7

92.123,220

4.456.075.9

50-1301351

3/8(9.53)7/8(22.2)

1/4( 6.35)

5.4355.1

Power supplyCooling

Heating

IPLV©Connectable indoor unit

Sound pressure levelRefrigerant pipe connections

Drainage pipe outside diameterWater side connecting pipeDC inverter compressor

Heat exchanger

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weightGross weightWater inelt temperatureAmbient temperature rangeAmbient humidity range

Capacity

Power input EER Capacity

Power input COP

Total capacityMax. quantity

Liquid pipeGas pipeOil blance pipe

QuantityCapacity

Crankcase heaterOil typeOil chargeTypeRated water flow volumePressure drop

Max.pressure of water pipe side

TypeFactory charging

V/Ph/HzkWRT

kBtu/hkcal/h

kWkW/kW

kWRT

kBtu/hkcal/h

kWkW/kW

%

dB(A)in.(mm)in.(mm)in.(mm)in.(mm)in.(mm)

kWkBtu/h

W

gal.(ml)

m3/hkPaPSIMPaPSI

Ibs.(kg)MPaPSIinchmminchmm

lbs.(kg)Ibs.(kg)°F(°C)°F(°C)

28.08.095.5

24,0806.104.5931.58.9

107.527,090

5.835.405.80

50-1301652

3/8(9.53)7/8(22.2)

1/4( 6.35)

6405.8

33.59.5

114.328,810

8.004.1937.510.7128.0

32,250 7.804.815.80

50-1302052

1/2(12.7)1(25.4)

1/4( 6.35)

7.2487.0

25/64( 10)1-1/4(31.8)

131.59107.840-80

FVC68D0.132(500)

Double-pipe heat exchanger

1.98287.2R410A4.4(2)4.4/2.6640/380

30-45/64×39-3/8×21-21/32780×1000×550

33-17/64×46-1/16×23-5/8845×1170×600

321(146)341(155)

44.6-113(7-45)32-104(0-40)Below 80%

380-415/3/60

Page 26: R410A DC Inverter VRF Series 60Hz-YONAN

Full DC

Inverter M

ini VR

F

Full DC

Inverter M

ini VR

F

53 54

Features

Mini VRF system operates stably at extreme temperature range from minus 15°C (5°F) to 48°C(118.4°F).

Full DC Inverter Mini VRF

NEWFashionDesign

Full DC Inverter Mini VRF with DC inverter compressor and DC fan motor delivers a highly efficient solution for small commercial buildings. Five to seven rooms require only one outdoor unit, and individual control is enabled in each room.

Wide Application RangeWide range of outdoor units

Flexible indoor units connection

The outdoor units’ capacity range from 10.5kW(35,800Btu/h) to 16kW(52,900Btu/h) which is ideal for small offices, villas, apartment and shops, making it perfect for commercial and residential application.

Mini VRF with intelligent control gives you independent zoning control with maximum flexibility.A single outdoor unit supports up to nine indoor units, freeing up considerable space outside. Use your backyard more wisely with much more space available created by less number of outdoor units.

10.5kW(35,800Btu/h)

12kW; 14kW; 16kW(40,900Btu/h; 47,800Btu/h; 52,900Btu/h)

Max. 7 indoor units for a 16kW(52,900Btu/h) outdoor unit installationMax. 6 indoor units for a 14kW(47,800Btu/h) outdoor unit installationMax. 6 indoor units for a 12kW(40,900Btu/h) outdoor unit installationMax. 5 indoor units for a 10.5kW(35,800Btu/h) outdoor unit installation

Wide operation temperature range

COOLING MODE

HEATING MODE

Outdoor temp.

48°C(118.4°F)

27°C(80.6°F)

-15°C(5°F)

-15°C(5°F)

0 10 20 30 40 50-10-2032 50 6814-4

°C(D.B.) °F(D.B.)86 104 122

Page 27: R410A DC Inverter VRF Series 60Hz-YONAN

55 56

Addresses of indoor units can be set automatically by outdoor units.Wireless controller can inquire and modify every indoor units address.

Space saving design

Easy installation

No need special room for the outdoor units. Easy installation: No special area is required for outdoor units. Easy transportaion: All outdoor units can be transported by elevator, which greatly simplifies installation and reduces time and labor.The Mini VRF system's indoor and outdoor units are almost as easy to install as residential airconditioning systems, making them ideal for small offices and shops.

The Mini VRF units are slimmer and more compact, resulting in significant savings in installation space. In some large residential and light commercial areas, such as villas, restaurants, usually it need more than one indoor unit, which in turn requires multiple outdoor units.Midea's MINI VRF system removes this problem, and retains buildings' original aesthetics.

The Mini VRF provides a total piping length possibility of 100m(328ft), a maximum height difference between outdoor and indoor units of 30m(98.4ft). The height difference between indoors unit can be up to 8m(26.2ft). These generous allowances facilitate an extensive array of system designs.

Easy to transport

Shield signal wire

Outdoor unit can distribute address for indoor unit.

50MRB92-RJK

Flexible piping design

High performance heat exchanger

High COP and EER values

The

long

est p

ipin

g le

ngth

is 7

0m(2

29.7

ft)

The

first

bra

nch

join

t to

the

farth

est I

DU

is 2

0m(6

5.6f

t)

The

IDU

to th

e ne

ares

t br

anch

join

t is

15m

(49.

2ft)

Leve

l diff

eren

ce b

etw

een

IDU

and

OD

U is

30m

(98.

4ft)

Leve

l diff

eren

ce b

etw

een

IDU

s is

8m

(26.

2ft)

1 Total pipe length is equal to all the liquid pipe or all the gas pipe length. 2 When the total equivalent pipe length of liquid side plus gas side is more than 90m(295.2ft), it needs to meet the specific conditions according to the installation part of the technical manual.

Permitted value10.5kW

(35,800Btu/h)12/14/16kW

(40,900/47,800//52,900Btu/h)

Total piping length (Actual)

Longest piping (L)

Piping length

Level difference

Level difference between IDU~IDU

Level difference between IDU~ODU

Equivalent piping length (from the farthest IDU to the first indoor branch jointC)

Outdoor unit up

Outdoor unit down

Actual length

Equivalent length

100m(328ft)

45m(146.7ft)

50m(164ft)

20m(65.6ft)

30m(98.4ft)

20m(65.6ft)

8m(26.2ft)

100m(328ft)

60m(196.9ft)

70m(229.7ft)

20m(65.6ft)

30m(98.4ft)

20m(65.6ft)

8m(26.2ft)

High Efficiency

New design Original design High efficiency inner-threaded pipe, enhance heat transfer.

Reduce air resistance

Hydrophilic fins + inner-threaded pipes

The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more power and enhance heat exchange performance.Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures a longer coil service life.

Easier Installation and Service

Auto addressing

EER

35,800 40,900 47,800 52,900 Btu/h

3.92 3.783.54 3.43

COP

35,800 40,900 47,800 52,900 Btu/h

3.97 3.8 3.7 3.56

Full DC

Inverter M

ini VR

F

Full DC

Inverter M

ini VR

F

Page 28: R410A DC Inverter VRF Series 60Hz-YONAN

57 58

Compressor (Twin Rotary) structure

Highly Efficient DC Motor:

- Creative motor core design

- High density neodymium magnet

- Concentrated type stator

-Wider operating frequency range

Better balance and Extremely Low Vibration:

- Twin eccentric cams

- 2 balance weights

Highly Stable Moving Parts:

- Optimal material matching rollers and vanes

-Optimize compressor drive technology

- Highly robust bearings

-Compact structure

Optimally designed fan shape and air discharge grille increases air volume and reduces running noise.

Noise reducing design

Newly Designed Fan Guard Powerful Large Propeller

New fan

Air deflector

New grille

More convenience in installation

A four-direction space is available for connecting pipes and wiring in various installation sites.

Front side Back sideRight side Bottom side

Front sideBottom side

Back side

Right side

At the heart of our system is a highly intelligent inverter driven compressor. This advanced technology enables the output of the outdoor unit to be modulated by the cooling or heating demands of the zone that it controls. This advanced system ensures precise temperature regulation and highly efficient energy usage, making a significant contribution to the limiting the impact on the environment.

High efficiency DC fan motor saved power up to 50%.

More convenient piping connector - branch box

New piping connection design

Easier and safer installation thanks to a branch box that simplifies piping work and the adoption of screw connection.

Both left and right pipe flare connectin from outdoor unit to branch box is reserved, which greatly simplifies field installation.

Two sets of pipe size converter are packed with branch box to transfer the pipe size from 6.35mm( 1/4in) to 9.53mm( 3/8in) and from 12.7mm( 1/2in) to 15.9mm( 5/8in).

The branch pipe is linear expansion design regulates the flow of refrigerant and reduces the noise. By locating the branch box in the ceiling or outside ,noise generated by the branch box can be kept clear of living spaces, thus makes noise level to a minimum.

All the piping leading to and from the branch box is connected using screw joints,which can be installed quickly and easily.

Brazing-free quick installation

Indoor installationThe branch box can be installed in the ceiling rather than outside. Removing the side and bottom covers provides easy access for maintaining inner components such as circuit boards.

x in the kept

d using screw joints,which can be

Low noise

Full DC inverter technology

Mot

or s

peed

(RP

M)

System pressure

DC inverter stepless adjustment

AC inverter multistep adjustment

Advanced Technologies

Full DC

Inverter M

ini VR

F

Full DC

Inverter M

ini VR

F

Page 29: R410A DC Inverter VRF Series 60Hz-YONAN

59 60

Note:1. The cooling conditions: indoor temp.: 27°C DB(80.6 °F), 19 °C WB(60°F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m. 2. The heating conditions: indoor temp.: 20°C DB(68°F), 15°C WB(44.6°F) outdoor temp.: 7 °C DB(42.8°F) equivalent pipe length: 5m drop length: 0m. 3. Sound level: Anechoic chamber conversion value, measured at a point 1 m(3.28ft) in front of the unit at a height of *m( 1m(3.28ft) for 105 model,1.2m(3.94ft) for 120~160model). During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance.

Note:1. The cooling conditions: indoor temp.: 27°C DB(80.6°F), 19°C WB(60 °F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m. 2. The heating conditions: indoor temp.: 20°C DB(68°C), 15°C WB(44.6°F) outdoor temp.: 7°C DB(42.8°F ) equivalent pipe length: 5m drop length: 0m. 3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(0.9m for 80model, 1m for 105 model,1.2m for 120~160model). During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance.

Specifications

Outdoor Unit

380-415V~3Ph~60HzYDV-V120W/DCN1

YDV-V140W/DCN1 YDV-V160W/DCN1

Specifications

Outdoor Unit

208-230V~60HzYDV-V105W/DVN1 YDV-V120W/DVN1

YDV-V140W/DVN1 YDV-V160W/DVN1

Full DC

Inverter M

ini VR

F

Full DC

Inverter M

ini VR

F

12.0

3.4

41.0

10,320

3.25

3.69

13.2

3.7

45.0

11,352

3.47

3.80

45-130

6

57

3/8( 9.53)

5/8( 15.9)

DC

2

6,000

3,531

85×2

Rotary

1

9.88

33.7

25

FV50S

0.23(870)

R410A

7.3(3.3)

4.4/2.6

640/380

203(92)

234(106)

Power supply

Cooling

Heating

Connectable

indoor unit

Sound pressure level

Pipe connections

Fan motor

Compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating

temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Type

Quantity

Air flow rate

Motor output

Type

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

m3/h

CFM

W

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

lbs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

14.0

3.9

48.0

12,040

3.95

3.54

15.4

4.3

52.5

13,244

4.16

3.70

45-130

6

57

3/8( 9.53)

5/8( 15.9)

DC

2

6,000

3,531

85×2

Rotary

1

9.88

33.7

25

FV50S

0.23(870)

R410A

8.6(3.9)

4.4/2.6

640/380

209(95)

234(106)

15.5

4.3

52.9

13,330

4.52

3.43

17.0

4.8

58.0

14,620

4.77

3.56

45-130

7

57

3/8( 9.53)

3/4( 19.1)

DC

2

6,000

3,531

85×2

Rotary

1

13.98

47.7

25

FV50S

0.37(1400)

R410A

8.6(3.9)

4.4/2.6

640/380

225(102)

249(113)

35-7/14×52-1/4×15-3/4

900×1327×400

40-35/64×57-21/64×17-1/8

1030×1456×435

5~118.4(-15~48)

5~80.6(-15~27)

1NCD/W061V-VDY1NCD/W041V-VDY1NCD/W021V-VDYledoM

380-415/3/60 Power supply

Cooling

Heating

Connectable

indoor unit

Sound pressure level

Pipe connections

Fan motor

Compressor

Refrigerant

Design pressure (High/Low)

Net dimension (W×H×D)

Packing size (W×H×D)

Net weight

Gross weight

Operating

temperature range

Capacity

Power input

EER

Capacity

Power input

COP

Total capacity

Max. quantity

Liquid pipe

Gas pipe

Type

Quantity

Air flow rate

Motor output

Type

Quantity

Capacity

Crankcase heater

Oil type

Oil charge

Type

Factory charging

Cooling

Heating

V/Ph/Hz

kW

RT

kBtu/h

kcal/h

kW

kW/kW

kW

RT

kBtu/h

kcal/h

kW

kW/kW

%

dB(A)

in.(mm)

in.(mm)

m3/h

CFM

W

kW

kBtu/h

W

gal.(ml)

Ibs.(kg)

MPa

PSI

inch

mm

inch

mm

lbs.(kg)

Ibs.(kg)

°F(°C)

°F(°C)

35-7/14×52-1/4×15-3/4

900×1327×400

40-35/64×57-21/64×17-1/8

1030×1456×435

5~118.4(-15~48)

5~80.6(-15~27)

Model YDV-V120W/DVN1 1NVD/W061V-VDY1NVD/W041V-VDY1NVD/W501V-VDY

10.5

2.9

35.8

9,030

2.68

3.92

11.5

3.2

39.2

9,890

2.90

3.97

45-130

5

57

3/8( 9.53)

5/8( 15.9)

DC

1

5,100

3,000

170

Rotary

1

7.13

24.3

25

FV50S

0.18(670)

R410A

6.6(3.0)

4.4/2.6

640/380

42-5/16×38-1/32×15-19/32

1075×966×396

44-3/32×43-5/16×17-1/8

1120×1100×435

172(78)

187(85)

12.0

3.4

41.0

10,320

3.25

3.69

13.2

3.7

45.0

11,352

3.47

3.80

45-130

6

57

3/8( 9.53)

5/8( 15.9)

DC

2

6,000

3,531

85×2

Rotary

1

9.88

33.7

25

FV50S

0.23(870)

R410A

7.3(3.3)

4.4/2.6

640/380

203(92)

234(106)

14.0

3.9

48.0

12,040

3.95

3.54

15.4

4.3

52.5

13,244

4.16

3.70

45-130

6

57

3/8( 9.53)

5/8( 15.9)

DC

2

6,000

3,531

85×2

Rotary

1

9.88

33.7

25

FV50S

0.23(870)

R410A

8.6(3.9)

4.4/2.6

640/380

209(95)

234(106)

15.5

4.3

52.9

13,330

4.52

3.43

17.0

4.8

58.0

14,620

4.77

3.56

45-130

7

57

3/8( 9.53)

3/4( 19.1)

DC

2

6,000

3,531

85×2

Rotary

1

13.98

47.7

25

FV50S

0.37(1400)

R410A

8.6(3.9)

4.4/2.6

640/380

225(102)

249(113)

208-230/1/60

Page 30: R410A DC Inverter VRF Series 60Hz-YONAN

Dimension Unit installation

(Wall or obstacle)

Maintainchannel

Air outlet

Air inlet

Air inlet

Single Unit installation

>6.56ft(2m)

>6.56ft(2m)

>6.56

ft(2

m)

>1.64ft(0.5m)

>9.84ft(3m)

>9.84ft(3m)

>9.84ft(3m)

>0.98ft(0.3m)

>0.98

ft(0

.3m)

>0.98ft(0.3m) >1.97ft

(0.6m)

>1.97

ft(0

.6m)

>1.97ft(0.6m)

Parallel installation

Fix with bolt

1327

(52-

1/4)

900(35-7/16)

600(23-5/8)

348(

13-4

5/64

)

320(

12-1

9/32

)

400(

15-3

/4)

360(

14-1

1/16

)

Front out pipe Back out pipeSide out pipe Undersurface out pipe

Fat pipe

R amplificationR

Unit Dimensions, unit: mm(in)10.5k

12/14/16kW

966(

38-1

/32)

1075(42-21/64)

990(38-31/32)

624(24-9/16)

354(

13-1

5/16

)

336(

13-1

5/64

)

396(

15-1

9/32

)36

6(14

-13/

32)

61 62

Full DC

Inverter M

ini VR

F

Full DC

Inverter M

ini VR

F

Page 31: R410A DC Inverter VRF Series 60Hz-YONAN

Indoor Units Lineup

One-way Cassette

Two-way Cassette

Compact Four-way Cassette

Four-way Cassette

Concealed Duct Unit (A5 Type)

High Static Pressure Duct

Ceiling&Floor

Wall mounted

Console

Fresh Air Processing Unit

Indoor Units Lineup

Indoor Units Lineup

Page 32: R410A DC Inverter VRF Series 60Hz-YONAN

Indoor Units Lineup

Indoor Units Lineup

One-way Cassette

Two-way Cassette

Compact Four-way Cassette

Four-way Cassette

Concealed Duct Unit(A5 Type)

High Static Pressure Duct

Wall mounted

Console

YDV-D XX Q1/N1-C

YDV-D XX Q1/N1-D

YDV-D XX Q2/VN1

YDV-D XX Q4/VN1-A3

YDV-D XX Q4/N1-D

YDV-D XX T2/VN1-BA5

YDV-D XX T2/VN1-DA5

YDV-D XX T1/VN1-B

YDV-D XX T1/N1-B

YDV-D XX G/N1YBYDV-D XX G/DN1YB

YDV-D XX G-R3/QN1Y

YDV-D XX Z/DN1-B

Fresh Air Processing Unit YDV-D XX T1/VN1-FA

Ceiling & Floor YDV-D XX DL/N1-C

YDV-D XX G/N1-SYDV-D XX G/DN1-S

10 types and more than 100 models are available to meet varied customer requirements.

18 22 28

Type2.8

9,600

0.8

1

36

3.6

12,300

1

1.25

45

4.5

15,400

1.3

1.6

56

5.6

19,100

1.6

2

71

7.1

24,200

2.0

2.5

80

8.0

27,300

2.3

2.8

90

9.0

30,700

2.6

3.2

100

10.0

34,100

2.9

3.6

112

11.2

38,200

3.2

4

125

12.5

42,700

3.5

4.5

160

16.0

54,600

5.0

6

200

20.0

68,200

5.7

8

250

25.0

85,300

7.1

9

280

28.0

95,500

8

10

2.2

7,500

0.6

0.8

1.8

6,100

0.5

0.6

400

40.0

136,500

11.4

14

450

45.0

153,500

12.8

16

Model

kW

Btu/h

Ton

HP

140

14.0

47,800

4.0

5

Page 33: R410A DC Inverter VRF Series 60Hz-YONAN

Super High Air Flow

Fresh air, improved air quality

LED DisplayLEDDISPLAY

1. Nominal cooling capacities are based on the following conditions: return air temp. : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temp.: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal)

2. Nominal heating capacities are based on the following conditions: return air temp.: 68°F(20°C)DB, outdoor temp.: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal)

3. Sound Level is measured 4.59ft(1.4m) below the unit

Notes:

YDV-D18Q1/VN1-D

YDV-D22Q1/VN1-D

YDV-D28Q1/VN1-D

YDV-D36Q1/VN1-D

YDV-D45Q1/VN1-C

YDV-D56Q1/VN1-C

kW 1.8 2.2 2.8 3.6 4.5 5.6

kcal/h 1500 1900 2400 3100 3900 4800

Btu/h 6100 7500 9600 12300 15400 19100

kW 2.2 2.6 3.2 4 5 6.3

kcal/h 1900 2200 2800 3400 4300 5400

Btu/h 7500 8900 10900 13600 17100 21500

580814141414gnilooC

580814141414gnitaeH

93.073.052.052.042.042.0gnilooC

93.073.052.052.042.042.0gnitaeH

m3/h 523/404/275 523/404/275 573/456/315 573/456/315 704/630/503 860/810/702

CFM 308/238/162 308/238/162 337/268/185 337/268/185 414/370/296 506/476/413

dB(A) 37/34/30 38/34/30 39/37/34 40/38/34 41/39/35 42/40/36

Type

Control method

Net dim.(W×H×D)

Gross dim.(W×H×D)

NetGross lbs.(kg)

Net dim.(W×H×D)

Gross dim.(W×H×D)

NetGross lbs.(kg)

L(flare) in.(mm) 1/4( 6.35) 3/8( 9.53)

G(flare) in.(mm) 1/2( 12.7) 5/8( 16)

Drain piping in.(mm)

45-5/32×7-7/8×-25-13/64(1147×200×640)

54-21/64×10-7/16×30-33/64(1380×265×775)

(69.5/82.1)31.5/37.2

56-7/64×25/64×29-23/32(1425×10×755)

59-1/16×4-21/64×34-1/4(1500×110×870)

Model

Power supply

Cooling capacity

Heating capacity

R410A

1-phase,220V,60Hz

27.8/35.3(12.5/16)

W

A

Rated input

Rated current

in.(mm)

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Refrigerant

Indoor Unit

EXV

38-3/16×6-1/32×16-9/64(970×153×410)

45-15/32×9-41/64×19-19/64(1155×245×490)

28.8/36.4(13/16.5)

46-29/64×63/64×18-5/16(1180×25×465)

48-1/2×4-7/32×20-23/64(1232×107×517)

7.7/11.5(3.5/5.2)

1/4 ( 6.35)

Standard Controller

in.(mm)

1/2( 12.7)

OD 63/64( 25)

Piping connections

Panel

Wireless remote controller (RM05/BG(T)E-A)

1/2( 12.7)

OD 63/64( 25)

46-29/64×63/64×18-5/16(1180×25×465)

48-1/2×4-7/32×20-23/64(1232×107×517)

7.7/11.5(3.5/5.2)

1/4( 6.35)

19.6/26.5(9/12)

OD 63/64( 25)

Indoor Units Lineup

Indoor Units Lineup

One-way Cassette

Compact design,ultra slim body with a minimum thickness of 6-1/32in.(153mm) for model 18-36,especially suitable for narrow ceiling , such as in lobbies and small meeting rooms.

Auto swing mechanism guarantees even distribution of airflow and better balance of room temperature.

Reserved fresh air intake port for high quality air supply requirement, create a comfort and healthy environment.

Special enzyme sterilization and filtering technology can filter the bacteria, smog, pollen, etc. Provide plenty clean, healthy and natural air supply.

Single-flow design suitscorner installation

Acetic acid Formol

Acetaldehyde

NH3

Standard built-in drain pump with 29-17/32in.(750mm) pump head.

Thickness 6-1/32in.(153mm) only UItra Thin

29-17/32in.(750mm)

Auto Addressing

Auto Restart

Cleanable Panel

Fresh Air

Anti-Cold Air FunctionFollow Me

Thickness 6-1/32in.(153mm) only Auto swing

Built-in Drain Pump

Page 34: R410A DC Inverter VRF Series 60Hz-YONAN

Super High Air FlowLED DisplayLEDDISPLAY

Indoor Units Lineup

Indoor Units Lineup

Optimized airflow duct with low resistance makes noise level get reduced greatly, min. 24dB(A).

Thanks to the stylish appearance and slim body, the unit can be harmonious with the room decoration and ambient. Slim body with only 11-13/16in.(300mm) height needs small suspended ceiling space. Installa-tion is free of story height limitation which makes the decoration much more flexible.

Standard built-in drain pump with 29-17/32in.(750mm) pump head (higher pumphead can be customized).

Flat-type suction grille design makes maintenance work very easy.

High airflow for high ceiling application guaran-tees equal comfort of large space. It makes every customer of the room get even distribu-tion of airflow and temperature.

Two-way Cassette

11-13/16in.(300mm) 12in.(305mm)

29-17/32in.(750mm)

Auto Addressing

Auto Restart

Cleanable Panel

Fresh Air

Follow Me Anti-Cold Air Function

wolfria hgiHnoitarepo teiuQ

Stylish design and slim body

Model YDV-D22Q2/VN1 YDV-D28Q2/VN1 YDV-D36Q2/VN1 YDV-D45Q2/VN1 YDV-D56Q2/VN1 YDV-D71Q2/VN1

Power supply 1-phase, 208-230V, 60Hz

Cooling capacity

Heating capacity

Power input

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Refrigerant

Wireless remote controller (RM05/BG(T)E-A)

Body

Panel

Piping

connections

Rated current

Cooling

Heating

Cooling

Heating

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

2.2

1,900

7,500

2.6

2200

8,900

78

78

0.35

0.35

674/509/381

397/300/224

33/29/24

2.8

2,400

9600

3.2

2,800

10,900

78

78

0.45

0.45

674/509/381

397/300/224

36/32/29

3.6

3,100

12,300

4

3,400

13,600

83

83

0.45

0.45

740/577/435

436/340/256

36/32/29

4.5

3,900

15,400

5

4,300

17,100

115

115

0.55

0.55

878/689/561

517/406/330

39/35/30

5.6

4,800

19,100

6.3

5,400

21,500

133

133

0.55

0.55

941/776/654

554/457/385

39/35/30

7.1

6,100

24,200

8

6,900

27,300

205

205

0.75

0.75

1,236/1,110/864

727/653/509

44/40/34

Standard Controller

Net dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

L(flare)

G(flare)

Drain piping

W

A

in.(mm)

in.(mm)

R410A

EXV

75/94(34/42.5)

23/33(10.5/15)

1/4(6.35)

1/2(12.7)

OD 1-17/64( 32)

75/94(34/42.5)

23/33(10.5/15)

1/4(6.35)

1/2(12.7)

OD 1-17/64( 32)

75/94(34/42.5)

23/33(10.5/15)

1/4(6.35)

1/2(12.7)

OD 1-17/64( 32)

80.5/99(36.5/45)

23/33(10.5/15)

1/4(6.35)

1/2(12.7)

OD 1-17/64( 32)

80.5/99(36.5/45)

23/33(10.5/15)

3/8(9.53)

5/8(15.9)

OD 1-17/64( 32)

80.5/99.3(36.5/45)

23/33(10.5/15)

3/8(9.53)

5/8(15.9)

OD 1-17/64( 32)

56-19/64×3-35/64×26-49/64(1430×90×680)

60-3/64×5-1/8×30-1/8(1525×130×765)

46-9/32×11-13/16×23-5/16(1172×300×592)

53-11/32×15-3/4×26-37/64(1355×400×675)

1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m) (horizontal)

2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. piping: 26.25ft (8m) (horizontal)

3.Sound Level is measured 4.59ft.(1.4m) below the unit

Notes:

Net dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

Built-in Drain Pump

Page 35: R410A DC Inverter VRF Series 60Hz-YONAN

Indoor Units Lineup

Indoor Units Lineup

Super High Air Flow

LED DisplayLEDDISPLAY

Extremely compact casing makes it perfectly match with the ambient decoration. Little space is required for installation into a shallow ceiling.Due to its compact body and light weight, all models can be installed without a hoist.

Streamline plate ensures quietnessAdvanced 3-D spiral fan design reduces the air resistance and operation noise.

The four air discharge port provides strong circulating air flow to cool or heat every corner of the room and realizes even temperature distribution; by choosing high airflow mode, high ceiling application over 1/8in.(3m) can get equal comfort.

360°air outlet provides strong circulating air flow to cool or heat every corner of the room and realizes even temperature distribution. Drain up pump with 19-11/16 in.(500mm) pump head

fitted as standard, max. up to 600mm pump head.

Compact Four-way Cassette

19-11/16 in.(500mm)

Diffuser

3-D spiral fan blade

Built-in Drain Pump

Auto Addressing

Auto Restart

Cleanable Panel

Fresh Air

Follow Me Anti-Cold Air Function

Compact design, easy installation and maintenance

Quiet operation, soft air supply Uniform air flow of four ways

360°Airflow outlet Lift pump

(22-7/16in (570mm)

(22-7/16in (570mm)

Model

Power supply 1-phase, 208-230V 60Hz

Cooling capacity

Heating capacity

Power input

Airflow rate(SH/H/M/L)

Sound pressure level(H/M/L)

Refrigerant

Body

Panel

Piping

connections

Rated current

Cooling

Heating

Cooling

Heating

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

YDV-D22Q4/VN1-A3

2.2

1,900

7,500

2.4

2,100

8,200

51

43

0.175

0.175

532/397/292/215

313/234/172/127

35.8/33.4/23.4

6.6/11(3/5)

1/4(6.35)

1/2(12.7)

OD 63/64( 25)

6.6/11(3/5)

1/4(6.35)

1/2(12.7)

OD 63/64( 25)

6.6/11(3/5)

1/4(6.35)

1/2(12.7)

OD 63/64( 25)

6.6/11(3/5)

1/4(6.35)

1/2(12.7)

OD 63/64( 25)

38.6/48.5(17.5/22) 38.6/48.5(17.5/22) 41.9/51.8(19/23.5) 41.9/51.8(19/23.5)

25-15/32×1-31/32×25-15/2(647×50×647)

28-5/32×4-27/32×28-5/32 (715×123×715)

22-7/16×10-15/64×22-7/16(570×265×570)

26-9/16×11-7/32×26-9/16(675×285×675)

YDV-D28Q4/VN1-A3

2.8

2,400

9,600

3.2

2,800

10,900

52

44

0.175

0.175

539/408/310/231

317/240/182/136

35.8/33.4/23.4

YDV-D36Q4/VN1-A3

3.6

3,100

12,300

4

3,400

13,600

58

50

0.21

0.21

632/496/359/263

372/292/211/155

41.5/35.6/28.8

YDV-D45Q4/VN1-A3

4.5

3,900

15,400

5

4,300

17,100

58

51

0.21

0.21

632/496/359/263

372/292/211/155

41.5/35.6/28.8

Standard Controller

Net dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

L(flare)

G(flare)

Drain piping

W

A

in.(mm)

in.(mm)

R410A

EXV

Wireless remote controller (RM05/BG(T)E-A)

1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft (8m) (horizontal)

2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. piping: 26.25ft (8m) (horizontal)

3.Sound Level is measured 4.59ft. (1.4m) below the unit.

Notes:

Net dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

Page 36: R410A DC Inverter VRF Series 60Hz-YONAN

Four-way Cassette

Streamline plate ensures quietness Advanced 3-D spiral fan design reduces the air

resistance and operation noise.

By adding digital tube displayer on the display board, the Error Codes can be displayed directly on it which helps to find and shoot the trouble.

Drain pump can take up the condenser water to 750mm which helps to make easier installation of the drain piping system.

Ultra-thin machine body for easy installation and maintenance, min. 230mm in height.

Fresh Air Intake

Diffuser

3-D spiral fan blade

To another room

The four air discharge port provides strong circulating air flow to cool or heat every corner of the room and realizes even temperature distribution; by choosing high airflow mode, high ceiling application over 1/8in.(3m) can get equal comfort.

9-1/16in.(230mm)29-17/32in.(750mm)

360°air outlet provides strong circulating air flow to cool or heat every corner of the room and realizes even temperature distribution

Built-in Drain Pump

Auto Addressing

Auto Restart

Cleanable Panel

Fresh Air

Follow Me

Quiet operation, soft air supply Four-way airflow(4-stage fan speed)

Easy troubleshooting Uniform airflow of four ways

Reserved multi-function ports360°Airflow outlet

High lift pump

Anti-Cold Air Function

Super High Air Flow

LED DisplayLEDDISPLAY

Model YDV-D28Q4/N1-D YDV-D36Q4/N1-D YDV-D45Q4/N1-D YDV-D56Q4/N1-D YDV-D71Q4/N1-D

Power supply 1-phase, 220-240V, 60Hz

Cooling capacity

Heating capacity

Power input

Airflow rate(SH/H/M/L)

Sound pressure level(H/M/L)

Refrigerant

Body

Panel

Rated current

Cooling

Heating

Cooling

Heating

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

2.8

2,400

9,600

3.2

2,800

10,900

85

85

0.4

0.4

1,155/847/766/640

680/499/451/377

42/38/35

3.6

3,100

12,300

4

3,400

13,600

85

85

0.4

0.4

1,155/847/766/640

680/499/451/377

42/38/35

4.5

3,900

15,400

5

4,300

17,100

98

98

0.4

0.4

1,207/864/755/658

710/509/444/387

42/38/35

5.6

4,800

19,100

6.3

5,400

21,500

98

98

0.4

0.4

1,207/864/755/658

710/509/444/387

42/38/35

7.1

6,100

24,200

8

6,900

27,300

115

115

0.5

0.5

1,327/1,157/955/749

781/681/562/441

45/42/39

Net dim.(W×H×D)Gross dim.(W×H×D)Net/gross

Net dim.(W×H×D)Gross dim.(W×H×D)Net/gross

Standard Controller

Piping

connections

L(flare)

G(flare)

Drain piping

W

A

in.(mm)

in.(mm)

R410A

EXV

Wireless remote controller (RM05/BG(T)E-A)

33-1/16×9-1/16×33-1/16(840×230×840)

37-19/32x10-15/64x37-19/32(955x260x955)

37-13/32x1-13/16x37-13/32 (950x46x950)

39-3/8x2-23/64x39-3/8 (1000x60x1000)

53 /61.7(24/28) 53 /61.7(24/28) 57.3 /66.2(26/30) 57.3 /66.2(26/30) 57.3 /66.2(26/30)

11.0/17.6(5/8)

1/4(6.35)

1/2(12.7)

11.0/17.6(5/8)

1/4(6.35)

1/2(12.7)

11.0/17.6(5/8)

1/4(6.35)

1/2(12.7)

11.0/17.6(5/8)

3/8(9.53)

5/8(15.9)

11.0/17.6(5/8)

3/8(9.53)

5/8(15.9)

Model YDV-D80Q4/N1- D YDV-D90Q4/N1- D YDV-D100Q4/N1- D YDV-D112Q4/N1- D YDV-D140Q4/N1-D

Power supply 1-phase, 220-240V, 60Hz

Cooling capacity

Heating capacity

Power input

Airflow rate(SH/H/M/L)

Sound pressure level(H/M/L)

Refrigerant

Body

Panel

Rated current

Cooling

Heating

Cooling

Heating

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

8

6,900

27,300

9

7,700

30,700

115

115

0.5

0.5

1,357/1,236/973/729

799/727/573/429

45/42/39

9

7,700

30,700

10

8,600

34,100

185

185

0.7

0.7

1,795/1,590/1,300/1,090

1,057/936/765/642

48/45/43

10

8,600

34,100

11

9,500

37,500

185

185

0.7

0.7

1,795/1,590/1,300/1,090

1,057/936/765/642

48/45/43

11.2

9,600

38,200

12.5

10,800

42,700

185

185

0.7

0.7

1,795/1,590/1,300/1,090

1,057/936/765/642

48/45/43

14

12,000

47,800

15

12,900

51,200

220

220

0.8

0.8

1,881/1,678/1,358/1,115

1,107/988/799/656

50/47/44

Net dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

Net dim.(W×H×D)

Gross dim.(W×H×D)

Net/gross

Standard Controller

Piping

connections

L(flare)

G(flare)

Drain piping

W

A

in.(mm)

in.(mm)

R410A

EXV

Wireless remote controller (RM05/BG(T)E-A)

33-1/16x9-1/16x33-1/16(840x230x840)

37-19/32x10-15/64x37-19/32(955x260x955)

57.3/66(26/30)

11.0/17.6(5/8)

3/8(9.53)

5/8(15.9)

70.5/81.6(32/37)

11.0/17.6(5/8)

3/8(9.53)

5/8(15.9)

70.5/81.6(32/37)

11.0/17.6(5/8)

3/8(9.53)

5/8(15.9)

70.5/81.6(32/37)

11.0/17.6(5/8)

3/8(9.53)

5/8(15.9)

70.5/81.6(32/37)

11.0/17.6(5/8)

3/8(9.53)

5/8(15.9)

37-13/32x1-13/16x37-13/32(950x46x950)

39-3/8x2-23/32x39-3/8 (1000x60x1000)

33-1/16x1-13/16x33-1/16(840x300x840)

37-19/32x11-13/16x37-19/32(955x330x955)

1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal)

2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal)

3. Sound Level is measured 4.59ft. (1.4m) below the unit

Notes:

OD 1-17/64( 32)

OD 1-17/64( 32)

Indoor Units Lineup

Indoor Units Lineup

Page 37: R410A DC Inverter VRF Series 60Hz-YONAN

External static pressure

Convenient installation

Flexible control and convenient for maintenance

The EXV is fixed inside of the indoor unit.Standard filter placed in an aluminum frame, which is removable downward from bottom.Suction chamber is included as standard equipment.Fresh air hole, air inlet/outlet flange are standard for easy duct connection.Air inlet from back is standard and from bottom as optional with the same connectable duct.

Standard Wired remote controller KJR-29B1/BK-E.The Electrical control box can be removed 1m away from the unit, easy to access when needs maintenance.(Should be required by client in advance and done by Midea CAC in factory).Standard functional port such as Remote On/Off Dry contact switch and Alarm signal output (220V).

Four speed fan motor (Super high speed as

an optional)

Change the wiring connection from ‘SH’ to

‘H’ to change the ESP.

Concealed Duct Unit (A5 Type)

Air intake from belowAir intake from back drain pump as standard

ceiling

Auto Addressing Cleanable Panel

Auto Restart Fresh Air

Anti-Cold Air Function

Follow Me

Built-in Drain Pump Wired Controller

29-17/32in.(750mm)

Connectable To Duct Super High Air Flow

8-9/32in.or 10-5/8in. or 11-13/16in.

Ceiling

Min.3/16in.(5mm)

Compact size

Only 8-9/32in.(210mm) (22~71 models) or 10-5/8in.(270mm) (80 to 112 models) or 11-13/16in.(300mm) (140 model) in height.

Notes:1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m)(horizontal)2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. piping: 26.25ft. (8m)(horizontal)3. Sound Level is measured 4.59ft. (1.4m) below the unit.* external static pressure are based on high speed indoor airflow.* Specifications are subject to change without prior notice for product improvement.

YDV-D22T2/VN1-DA5

YDV-D28T2/VN1-DA5

YDV-D36T2/VN1-DA5

YDV-D45T2/VN1-DA5

YDV-D56T2/VN1-DA5

YDV-D71T2/VN1-DA5

kW 2.2 2.8 3.6 4.5 5.6 7.1

kcal/h 1900 2400 3100 3900 4800 6100

Btu/h 7500 9600 12300 15400 19100 24200

kW 2.4 3.2 4 5 6.3 8

kcal/h 2100 2800 3400 4300 5400 6900

Btu/h 8200 10900 13600 17100 21500 27300

001001772766gnilooC 125

001001772766gnitaeH 125

84.084.082.082.082.0gnilooC 0.6

84.084.082.082.082.0gnitaeH 0.6

m3/h 578/523/443/378 580/552/443/373 623/566/481/430 827/811/653/527 827/811/653/527 1191/1056/880/684

CFM

Pa

340/308/261/223 342/325/261/220 367/333/283/253 487/477/384/310 487/477/384/310 701/622/518/403

dB(A) 36/35/32

10(10-30) 10(10-30) 10(10-30) 10(10-30) 10(10-30) 10(10-30)

37/35/32 38.6/37.5/33.8 39/37.9/34 39/37.9/34 41.4/39/35

TypeControl method

Net dim.(W×H×D)36-7/32×8-17/64×19-

11/16(920×210×500)

36-7/32×8-17/64×19-

11/16(920×210×500)

44-7/8-17/64×19-11/16(1140×210×500)

Gross dim.(W×H×D)43-7/64×11-7/32×20-43/64

(1095×285×525)

43-7/64-7/32×20-43/64(1095×285×525)

51-37/64-7/32×20-43/64(1310×285×525)

NetGross lbs.(kg) 38.6/44.1(17.5/20) 38.6/44.1(17.5/20) 38.6/44.1(17.5/20) 22.5/25.5 22.5/25.5 28/31

L(flare) in.(mm) 1/4( 6.35) 1/4( 6.35) 1/4( 6.35) 1/4( 6.35) 3/8( 9.53) 3/8( 9.53)

G(flare) in.(mm) 1/2( 12.7) 1/2( 12.7) 1/2( 12.7) 1/2( 12.7) 5/8( 15.9) 5/8( 15.9)

Drain piping in.(mm) OD 1-17/64( 32) OD 1-17/64( 32) OD 1-17/64( 32) OD 1-17/64( 32) OD 1-17/64( 32) OD 1-17/64( 32)

Indoor Unit

in.(mm)

Piping connections

Standard Controller

27-9/16×8-17/64×19-11/16(700×210×500)

34-1/4×11-7/32×20-43/64(870×285×525)

Wireless remote controller (KJR-29B1/BK-E)

R410A

EXV

Model

Power supply

Cooling capacity

Heating capacity

Rated input

W

Rated current

A

Airflow rate(SH/H/M/L)

EXP(external static pressure)

Sound pressure level(H/M/L)

Refrigerant

1-phase,220V,60Hz

YDV-D80T2/VN1-BA5

YDV-D90T2/VN1-BA5

YDV-D112T2/VN1-BA5

YDV-D140T2/VN1-BA5

412.1198Wkkcal/h 6900 7700 9600 12000Btu/h 27300 30700 38200 47800

5.515.21019Wkkcal/h 7700 8600 10800 13300Btu/h 30700 34100 42700 52900

253873431331gnilooC253873431331gnitaeH5518.111gnilooC5518.111gnitaeH

m3 052,1/935,1/987,1/819,1983,1/255,1/057,1/257,1168/810,1/622,1/004,1h/CFMPa

824/722/599/5071,400/1,226/1,018/861

824/722/599/507 1,031/1,030/913/818 1,129/1,053/906/736

dB(A) 45.4/39.8/37 45.4/39.8/37 48.0/41.9/38 47.7/43.2/39Type

Control methodNet dim.(W×H×D) 50-25/32×11-13/16×34-1

/16(1290×300×865)55-1/8×14-49/64×36-27

/64(1400×375×925)Gross dim.(W×H×D)

NetGross lbs.(kg) 84/102.5(38/46.5) 88.2/105.8 40/48 88.2/105.8 40/48 108.0/127.9(49/58)L(flare) in.(mm) 3/8( 9.53) 3/8( 9.53) 3/8( 9.53) 3/8( 9.53)G(flare) in.(mm) 5/8( 15.9) 5/8( 15.9) 5/8( 15.9) 5/8( 15.9)Drain piping in.(mm)

Model

Power supply

Cooling capacity

Heating capacity

Wtupni detaR

Piping connections

)eriw noitcennoc sretem 6()E-KB/1B92-RJK( rellortnoc sseleriWrellortnoC dradnatSOD 1-17/64( 32)

Atnerruc detaR

Airflow rate (SH/H/M/L)

Sound pressure level(H/M/L)EXP(external static pressure)

RefrigerantR410AEXV

1-phase,220V,60Hz

Indoor Unitin.(mm)

48-27/64×10-5/8×30-33/64(1230×270×775)

53-11/32×13-25/31×31-19/64 1355×350×795

Indoor Units Lineup

Indoor Units Lineup

20(10-50) 20(10-50) 40(10-80) 40(10-100)

Page 38: R410A DC Inverter VRF Series 60Hz-YONAN

High Static Pressure Duct

Added flexibility with four speed fan

Convenient installation

Flexible control and convenient for maintenance

Option

Just exchange the wiring connection of ‘MH’ and ‘Me’.(for 71~160 model)

Four speed fan motor (medium high speed as an option only for 71~160 model)External static pressure can be up to 196Pa (71~160 models) or 250Pa (400~450 models).

The EXV is fixed inside the indoor unit (for 71~450 model), no need extra connection. Standard filter placed in an aluminum frame, which is removable downward from bottom.Flange for air in/outlet duct connection is standard.

420mm 450mm

Min.

INDOOR UNIT

Standard Wired remote controller KJR-29B1/BK-E, and wireless remote controller RM05/BG(T)E-A is as an option.The display board is connected with the E-box in factory, easier trouble-shooting by LED display.Easy access filters both in rear & bottomStandard functional port such as remote on/off dry contact.

The max distance of air supply is about 45.9ft.(14m) while the height of air supply is about 21.3ft.(6.5m).With 16-17/32in(420mm) thickness body, the minimum distance above the ceiling is 17-23/32in(450mm).

Optional drain pumps with 29-17/32in.(750mm) pumphead.

the longest distanceof air supply is 14m

The height of airsupply is 6.5m

INDOOR UNIT

Fresh air in take

nruter riAylppus riA

Auto Addressing

Auto Restart

Cleanable Panel

Fresh Air

Follow Me

Wired Controller

Anti-Cold Air Function

Connectable To Duct

Flexible duct design

ceiling

29-17/32in.(750mm)

Double-skin drainage pan

Double-skin drainage pan, double production for your ceiling.(for 71~450 model)

Model

208~230V-1Ph-60HzPower Supply

Capacity

EXP (external static pressure)

Sound pressure level(H/M/L)

Net/Gross Weight

Indoor air flow (H/M/L)

Refrigerant

Piping Connections

Cooling

Heating

Type

Control method

L(flare)

G(flare)

Drain piping

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

Pa

dB(A)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

YDV-D71T1/VN1-B

102.6/114.7(46.5/52)

3/8( 9.53)

5/8( 15.9)

OD 1-17/64( 32)

7.1

6,100

24,200

8

6,900

27,300

414

414

1.8

1.8

1683/1550/1317

990/912/775

40(30~196)

48/46/44.5

YDV-D80T1/VN1-B

102.6/114.7(46.5/52)

3/8( 9.53)

5/8( 15.9)

OD 1-17/64( 32)

8

6,900

27,300

9

7,700

30,700

402

402

1.8

1.8

1683/1550/1317

990/912/775

40(30~196)

48/46/44.5

YDV-D90T1/VN1-B

110.3/124.6(50/56.5)

3/8( 9.53)

5/8( 15.9)

OD 1-17/64( 32)

9

7,700

30,700

10

8,600

34,100

409

409

1.8

1.8

2240/2020/1590

1318/1188/935

40(30~196)

52/49/47

YDV-D112T1/VN1-B

110.3/124.6(50/56.5)

3/8( 9.53)

5/8( 15.9)

OD 1-17/64( 32)

11.2

9,600

38,200

12.5

10,800

42,700

409

409

2.01

2.01

2186/1975/1560

1286/1162/918

50(30~ 196)

52/49/47

R410A

EXV

Net dimension W×H×D

W×H×DPacking dimension

in.(mm)

in.(mm)

Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. Piping:26.25ft(8m)(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)

3. Sound Level is measured 4.59ft. (1.4m) below the unit.

* Specifications are subject to change without prior notice for product improvement.

Wired controller KJR-29B1/BK-E (6m wrie is standard)-rellortnoC dradnatS

37-31/64×16-17/32×27-11/64(952×420×690)

42-29/32×17-21/64×30-15/64(1090×440×768)

Model

208~230V-1Ph-60HzPower Supply

Capacity

EXP (external static pressure)

Sound pressure level(H/M/L)

Net/Gross Weight

Standard Controller

Indoor air flow (H/M/L)

Refrigerant

Piping Connections

Cooling

Heating

Type

Control method

L(flare)

G(flare)

Drain piping

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

Pa

dB(A)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

YDV-D140T1/VN1-B

149.9/154.3(68/70)

3/8( 9.53)

5/8( 15.9)

OD 1-17/64( 32)

14

12,000

47,800

16

13,800

54,600

527

527

2.2

2.2

2969/2688/2469

1746/1582/1452

50(30~ 196)

53/50/48

YDV-D160T1/VN1-B

153.3/167.6(69.5/76)

3/8( 9.53)

5/8( 15.9)

OD 1-17/64( 32)

16

13,800

54,600

18

15,500

61,400

532

532

2.2

2.2

2969/2688/2469

1746/1582/1452

50(30~ 196)

54/52/50

R410A

EXV

Net dimension W×H×D

W×H×DPacking dimension

in.(mm)

in.(mm) 56-17/32×17-23/32×30-15/64(1436×450×768)

47-1/4×15-3/4×23-5/8 (1,200×400×600)

Wired controller KJR-29B1/BK-E(6m wrie is standard)

YDV-D400T1/N1

40

34400

136500

45

38700

153,500

1,600

1,600

7.5

7.5

7083/6200/4630

4166/3647/2723

196(50~250)

61/59/56

YDV-D450T1/N1

45

38,700

153,500

50

43,000

170600

1,600

1,600

7.5

7.5

7083/6200/4630

4166/3647/2723

196(50~250)

61/59/56

511/540(232/245)

1/2( 12.7)

7/8( 22.2)

OD 1-17/64( 32)

511/540(232/245)

1/2( 12.7)

7/8( 22.2)

OD 1-17/64( 32)

77-9/16×26-19/64×33-51/64(1,970×668×858.5)

82-31/64×31-1/2×37-61/64(2,095×800×964)

Power input

Rated current

Cooling

Heating

Cooling

Heating

W

A

Power input

Rated current

Cooling

Heating

Cooling

Heating

W

A

Indoor Units Lineup

Indoor Units Lineup

Page 39: R410A DC Inverter VRF Series 60Hz-YONAN

Ceiling & Floor

Panel with LED display

Convenient for installation

Low noise, creates quiet and comfortable environment

Auto swing and wide angle air flow

The front panel and display panel have different colors to choose: white and brown to big panel, blue and brown for small panel, and the other colors can be customized according to the customers’ demands.

1.The unit has auto horizontal swing and auto vertical swing function, which supplies more even and comfortable airflow.

2.Three airflow speed: high/middle/low, double air guides.3.Adoption of the electronic expansion valve, ensure precise flow

control, as well lower modulation noise when EXV operating.4.Smoother airflow with less turbulence. Owing to the multiple-blade

fan and the air guide design, the airflow is getting smoother and more comfortable.

The ceiling type can be easily installed into a corner of the ceiling even if the ceiling is very narrowIt is especially useful when installation of an air conditioner in the center of the ceiling is impossible due to a structure such as one lighting

Slim and sleek design starting at just 66lbs.(30kg) in weight means quick,easy & neat installation.Low noise operation, lowest to 36dB(A)

Auto Swing & Wide-angle Airflow

>20

198mm

Drop ceiling

Air Outlet

The unit can be installed either horizontally on the ceiling or vertically against the wall.

Built-in Drain Pump

Auto Addressing

Auto Restart

Cleanable Panel

Fresh Air

Follow Me Anti-Cold Air Function

LED DisplayLEDDISPLAY

Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal)3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance. Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.

* Specifications are subject to change without prior notice for product improvement.

Cooling capacity

Power supply

Heating capacity

Power input

Rated current

Cooling

Heating

Cooling

Heating

57.3/70.6(26/32)

1/4( 6.35)

1/2( 12.7)

OD 5/8( 16)

61.7/75.0(28/34)

1/4( 6.35)

1/2( 12.7)

OD 5/8( 16)

61.7/75.0(28/34)

3/8( 9.53)

5/8( 15.9)

OD 5/8( 16)

61.7/75.0(28/34)

3/8( 9.53)

5/8( 15.9)

OD 5/8( 16)

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net dimension(W×H×D)

Packing dimension(W×H×D)

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

YDV-D36DL/N1-C YDV-D45DL/N1-C YDV-D56DL/N1-C

220~240V-1Ph-60Hz

YDV-D71DL/N1-C

3.6

3,100

12,300

4

3,400

13,600

49

49

0.55

0.55

600/480/400

353/283/235

40/38/36

4.5

3,900

15,400

5

4300

17,100

147

147

0.55

0.55

750/650/550

441/383/324

43/41/38

5.6

4,800

19,100

6.3

5,400

21,500

147

147

0.55

0.55

750/650/550

441/383/324

43/41/38

7.1

6,100

24,200

8

6,800

27,300

147

147

0.57

0.57

750/650/550

441/383/324

43/41/38

R410A

EXV

Wireless remote controller (RM05/BG(T)E-A)

Model

Net/Gross weight

in.(mm)

in.(mm)

38-31/32x25-31/32x8-1/8

(990x660x206)

42-7/8x29-9/32x11-21/32

(1,089x744x296)

Cooling capacity

Power supply

Heating capacity

Power input

Rated current

Cooling

Heating

Cooling

Heating

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net dimension(W×H×D)

Packing dimension(W×H×D)

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

220~240V-1Ph-60Hz

76.1/90.4(34.5/41)

3/8( 9.53)

5/8( 15.9)

OD 5/8( 16)

YDV-D80DL/N1-C

8

6,900

27,300

9

7,700

30,700

185

185

0.6

0.6

1,200/900/700

706/530/412

45/43/40

76.1/90.4(34.5/41)

3/8( 9.53)

5/8( 15.9)

OD 5/8( 16)

YDV-D90DL/N1-C

9

7,700

30,700

10

8,600

34,100

185

185

0.6

0.6

1,200/900/700

706/530/412

45/43/40

119.0/130.1(54/59)

3/8( 9.53)

5/8( 15.9)

OD 5/8( 16)

YDV-D112DL/N1-C

11.2

9,600

38,200

12.5

10,800

42,700

241

241

0.83

0.83

1,980/1,860/1,730

1,165/1,095/1,018

47/45/42

YDV-D160DL/N1-C

119.0/130.1(54/59)

3/8( 9.53)

5/8( 15.9)

OD 5/8( 16)

YDV-D140DL/N1-C

14

12,000

47,800

15.5

13,000

52,900

241

241

0.83

0.83

1,980/1,860/1,730

1,165/1,095/1,018

47/45/42

R410A

EXV

Wireless remote controller (RM05/BG(T)E-A)

Model

Net/Gross weight

in.(mm)

in.(mm)

50-25/64 x8-7/64x25-63/64

(1280x206x660)

54-19/64x11-21/32x29-19/64

(1379x296x744)

65-3/4 x9-39/64x26-49/64

(1670 x244x680)

69-29/64 x12-61/64x29-59/64

(1764x329x760)

126.5/139.7(57.5/63.5)

3/8( 9.53)

5/8( 15.9)

OD 63/64( 16)

16

13,800

54,600

18

15,477

61,400

378

378

1.75

1.75

2,300/2,100/1,800

1,354/1,236/1,060

47/45/42

65-3/4x11-7/32x26-49/64

(1670x285x680)

69-7/8x14-27/32x29-59/64

(1775x377x760)

Indoor Units Lineup

Indoor Units Lineup

Page 40: R410A DC Inverter VRF Series 60Hz-YONAN

Auto Addressing

Auto Restart

Cleanable Panel

Follow Me

S type panel C type panel

R type panel

Wall mounted

S type panel

R typee panel

Auto swing louver Easy maintenance

The mechanical expansion valve offers 2,000-stage element positions to ensure precise flow control and less modulation noise when the EXV is operating for a quiet and comfortable environment. Three air flow speeds: low, medium and high; double air guides. Smoother airflow and less turbulence is ensured by the multi-blade fan and the air guide design.

The front panel can be removed for easy maintenance access.

The front panel and display panel have different colors to choose: white and brown for big panel, blue and brown for small panel.

Open panel

auto swing louver function ensures that the air direction corresponds to the mode selected.

Rear

Left Right

1

2

3

4

Step

Swing

Anti-Cold Air Function

LED DisplayLEDDISPLAY

Panel with LED display

Convenient installation

Optimal comfort through better flow control and quiet operations

Multi-refrigerant outlet pipe method: left\right\rear, more flexible for installation.The EXV is built-in the indoor unit, compact size, longer the connection pipe; Gas pipe: 18-27/64in.(468mm)/Liquid pipe: 21-21/32in.(550mm), more flexible for the installation.Adopts new type fixing plate, which means easy to install and stable.

S type panel

Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m)(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.

* Specifications are subject to change without prior notice for product improvement.

Cooling capacity

Heating capacity

Power supply

Power input

Rated current

Cooling

Heating

Cooling

Heating

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net weight

Gross weight

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

YDV-D22G/N1-S YDV-D28G/N1-S

220~240V-1Ph-60Hz

YDV-D36G/N1-S

28.7(13)

37.1(16.8)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

28.7(13)

37.1(16.8)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

28.7(13)

37.1(16.8)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

33.4(15.1)

43/19.5

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

33.4(15.1)

43/19.5

3/8( 9.53)

5/8( 15.9)

OD 21/32( 16.5)

36-1/32x11-13/32x9-1/16(915×290×230)

40-5/32x15-11/32x12-13/32(1,020×390×315)

42-7/32X12-13/32X9-1/16 (1,072×315×230)

46-15/32X16-11/32X12-13/32 (1,180×415×315)

2.2

1,900

7,500

2.4

2,100

8,200

28

28

0.14

0.14

525/480/430

309/283/253

35/32/29

2.8

2,400

9,600

3.2

2,800

10,900

28

28

0.14

0.14

525/480/430

309/283/253

35/32/29

3.6

3,100

12,300

4

3,400

13,600

28

28

0.14

0.14

590/520/480

347/306/283

35/32/29

R410A

EXV

Model YDV-D45G/N1-S YDV-D56G/N1-S

4.5

3,900

15,400

5

4,300

17,100

51

51

0.2

0.2

860/755/630

506/444/371

40/38/34

5.6

4,800

19,100

6.3

5,400

21,500

51

51

0.2

0.2

925/860/755

544/506/444

40/38/34

Net dimension(W×H×D)

Packing dimension(W×H×D)

in.(mm)

in.(mm)

Cooling capacity

Heating capacity

Power supply

Power input

Rated current

Cooling

Heating

Cooling

Heating

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net weight

Gross weight

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

YDV-D22G/DN1-S YDV-D28G/DN1-S

220~240V-1Ph-60Hz

YDV-D36G/DN1-S

29.3(13.3)

37.7(17.1)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

29.3(13.3)

37.7(17.1)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

29.3(13.3)

37.7(17.1)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

34.2(15.5)

43.9(19.9)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

34.2(15.5)

43.9(19.9)

3/8( 9.53)

5/8( 15.9)

OD 21/32( 16.5)

36-1/32x11-13/32x9-1/16(915×290×230)

40-5/32x15-11/32x12-13/32(1,020×390×315)

42-7/32X12-13/32X9-1/16 (1,072×315×230)

46-15/32X16-11/32X12-13/32 (1,180×415×315)

2.2

1,900

7,500

2.4+0.75

2,100+600

8,200+2,600

28

28

0.14

0.14+3.38

525/480/430

309/283/253

35/32/29

2.8

2,400

9,500

3.2+0.75

2,800+600

10,900+2,600

28

28

0.14

0.14+3.38

525/480/430

309/283/253

35/32/29

3.6

3,100

12,300

4+0.75

3,400+600

13,600+2,600

28

28

0.14

0.14+3.38

590/520/480

347/306/283

35/32/29

R410A

EXV

Model YDV-D45G/DN1-S YDV-D56G/DN1-S

4.5

3,900

15,400

5+0.9

4,300+800

17100+3100

51

51

0.2

0.20+4.05

860/755/630

506/444/371

40/38/34

5.6

4,800

19,100

6.3+0.9

5,400+800

21,500+3,100

51

51

0.2

0.20+4.05

925/860/755

544/506/444

40/38/34

Net dimension(W×H×D)

Packing dimension(W×H×D)

in.(mm)

in.(mm)

Wireless remote controller (RM05/BG(T)E-A)

Wireless remote controller (RM05/BG(T)E-A)

Indoor Units Lineup

Indoor Units Lineup

Page 41: R410A DC Inverter VRF Series 60Hz-YONAN

R type panel

Cooling capacity

Power supply

Heating capacity

Power input

Rated current

Cooling

Heating

Cooling

Heating

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net dimension(W×H×D)

Packing dimension(W×H×D)

Net weight

Gross weight

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

in.(mm)

in.(mm)

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

MDV-D71G-R3/QN1Y

1-phase, 220-240V, 60Hz

R410A

EXV

Wireless remote controller (RM05/BG(T)E-A)

Model

49-7/32×12-51/64×9-1/16(1250×325×230)

52-61/64×13-3/16×16-59/64(1345×335×430)

43.8(19.9)

55.1(25)

3/8( 9.53)

5/8( 15.9)

OD 21/32( 16.5)

7.1

6,100

24,200

8

6,900

27,300

79

79

0.33

0.33

1,190/880/680

700/518/400

45/42/39

8

6,900

27,300

9

7,700

30,700

95

95

0.39

0.39

1,320/840/640

776/494/376

48/43/38

MDV-D80G-R3/QN1Y MDV-D90G-R3/QN1Y

9

7,700

30,700

10

8,600

34,100

95

95

0.39

0.39

1,320/840/640

776/494/376

49/43/38

Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal)3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance. Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.

* Specifications are subject to change without prior notice for product improvement.

Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m)(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.

* Specifications are subject to change without prior notice for product improvement.

Cooling capacity

Heating capacity

Power supply

Power input

Rated current

Cooling

Heating

Cooling

Heating

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net weight

Gross weight

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

MDV-D22G/DN1YB MDV-D28G/DN1YB

220-240V~, 1Ph, 60Hz

MDV-D36G/DN1YB

36-1/32×11-13/32×8-9/32(915×290×210)

40-5/32×15-5/32×11-13/16 (1,020×385×300)

42-7/32×12-13/32×8-9/32(1,070×315×210)

45-7/8×15-9/16×11-7/32(1,165×395×285)

2.2

1,900

7,500

2.4+0.75

2,200+600

8,900+2,500

28

28

0.14

0.14+3.38

557/520/467

328/306/275

35/32/29

2.8

2,400

9,600

3.2+0.75

2,800+600

10,900+2,500

28

28

0.14

0.14+3.38

557/520/467

328/306/275

35/32/29

3.6

3,100

12,300

4+0.75

3,400+600

13,600+2,500

28

28

0.14

0.14+3.38

557/520/467

328/306/275

35/32/29

R410A

EXV

Model MDV-D45G/DN1YB MDV-D56G/DN1YB

4.5

3,900

15,400

5+0.9

4,300+800

17,100+3,100

45

45

0.2

0.2+4.05

842/722/597

496/425/351

40/38/34

5.6

4,800

19,100

6.3+0.9

5,400+800

21,500+3,100

45

45

0.2

0.2+4.25

842/722/597

496/425/351

40/38/34

Net dimension(W×H×D)

Packing dimension(W×H×D)

in.(mm)

in.(mm)

Wireless remote controller (RM05/BG(T)E-A)

C type panel

Cooling capacity

Heating capacity

Power supply

Power input

Rated current

Cooling

Heating

Cooling

Heating

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net weight

Gross weight

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

MDV-D22G/N1YB MDV-D28G/N1YB

220-240V~, 1Ph, 60Hz

MDV-D36G/N1YB

36-1/32×11-13/32×8-9/32(915×290×210)

40-5/32×15-5/32×11-13/16(1,020×385×300)

2.2

1,900

7,500

2.4

2,200

8,900

28

28

0.14

0.14

557/520/467

328/306/275

35/32/29

2.8

2,400

9,600

3.2

2,800

10,900

28

28

0.14

0.14

557/520/467

328/306/275

35/32/29

3.6

3,100

12,300

4

3,400

13,600

28

28

0.14

0.14

557/520/467

328/306/275

35/32/29

R410A

EXV

Model MDV-D45G/N1YB MDV-D56G/N1YB

4.5

3,900

15,400

5

4,300

17,100

45

45

0.2

0.2

842/722/597

496/425/351

40/38/34

5.6

4,800

19,100

6.3

5,400

21,500

45

45

0.2

0.2

842/722/597

496/425/351

40/38/34

Net dimension(W×H×D)

Packing dimension(W×H×D)

in.(mm)

in.(mm)

Wireless remote controller (RM05/BG(T)E-A)

26.5(12)

36.4(16)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

26.5(12)

35.3(16)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

26.5(12)

35.3(16)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

33.1(15)

41.9(19)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

33.1(15)

41.9(19)

3/8( 9.53)

5/8( 15.9)

OD 21/32( 16.5)

42-7/32×12-13/32×8-9/32(1,070×315×210)

45-7/8×15-9/16×11-7/32(1,165×395×285)

26.5(12)

38.6(17.5)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

26.5(12)

38.6(17.5)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

26.5(12)

38.6(17.5)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

33.1(15)

41.9(19)

1/4( 6.35)

1/2( 12.7)

OD 21/32( 16.5)

33.1(15)

41.9(19)

3/8( 9.53)

5/8( 15.9)

OD 21/32( 16.5)

Indoor Units Lineup

Indoor Units Lineup

Page 42: R410A DC Inverter VRF Series 60Hz-YONAN

Console

Compact size and stylish

Flexible installation

High comfort

Powerful mode can be selected for rapid cooling or heating

The elegant and thin unit body complements the existing decor and saves space.The EXV is installed inside of the indoor unit for added compactness.

Can be installed on the floor or lower wall As a floor standing type, it can be semi or fully accessed without losing capacity.

Flexible air blow: vertical auto swing and wide angle louvers ensure that warm air reaches every cornerof the room and increases the air flow coverage.Indoor unit adopts DC motor with five fan speeds to meet different requirements.Applies the Fujikoki mechanical expansion valve which offers 2,000-stage element positions to ensure precise flow control and lower modulation noise when the EXV is operating.

COOLING MODE

Quick cooling To maintain temperature Anti-cold air Normal operation

HEATING MODE

Two air outlets and four air inlets Low-noise design

High efficiency filterBuilt in formaldehyde nemesis filterActive-carbon and biological anti-virus filter are optional.

Four directions of air inlet;two options of air outlet: Up and Down; or Up only.

Five-speed indoor unit; low noise; low power consumption.

Air Outlet

Air Inlet

Low noise operation, lowest to 26dB(A)Bottom, top, and right/left side, for better ventilation.

Air Outlet

Auto Addressing

Auto Restart Cleanable Panel

Follow Me

Anti-Cold Air Function

LED DisplayLEDDISPLAY

Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m) (horizontal)

2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)

3.Sound level is measured 3.28ft.(1m) from the air out-let in horizontal distance and 3.28ft.(1m) above the floor in vertical distance.

* Specifications are subject to change without prior notice for product improvement.

Cooling capacity

Power supply

Heating capacity

Power input

Rated current

Cooling

Heating

Cooling

Heating

Refrigerant

Airflow rate(H/M/L)

Sound pressure level(H/M/L)

Net dimension(W×H×D)

Packing dimension(W×H×D)

Net weight

Gross weight

Piping

connections

L(flare)

G(flare)

Drain piping

Standard Controller

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

dB(A)

Type

Control method

in.(mm)

in.(mm)

lbs.(kg)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

W

A

YDV-D22Z/DN1-B YDV-D28Z/DN1-B YDV-D36Z/DN1-B

220-240V~, 1Ph, 60Hz

YDV-D45Z/DN1-B

30.9(14)

42.9(19)

1/4( 6.35)

1/2( 12.7)

OD 5/8( 16)

33(15)

44.1(20)

1/4( 6.35)

1/2( 12.7)

OD 5/8( 16)

33(15)

44.1(20)

1/4( 6.35)

1/2( 12.7)

OD 5/8( 16)

33(15)

44.1(20)

1/4( 6.35)

1/2( 12.7)

OD 5/8( 16)

2.2

1,900

7,500

2.6

2,200

8,900

20

20

0.09

0.09

468/450/395

275/265/232

38/32/26

2.8

2,400

9,600

3.2

2,800

10,900

25

25

0.11

0.11

468/450/395

275/265/232

39/33/27

3.6

3,100

12,300

4.0

3,400

13,600

25

25

0.11

0.11

467/427/395

275/251/232

39/33/27

4.5

3,900

15,400

5.0

4,300

17,100

45

45

0.2

0.2

540/481/421

318/283/248

42/39/36

Wireless remote controller (RM05/BG(T)E-A)

Model

R410A

EXV

27-9/16×23-5/8×8-9/32 (700×600×210)

31-7/8×27-15/16×12 (810×710×305)

Indoor Units Lineup

Indoor Units Lineup

Page 43: R410A DC Inverter VRF Series 60Hz-YONAN

Fresh air is imported, provides a healthy and comfortable living environment.

Both fresh air filtration and heating/cooling can be achieved in a single system.Indoor units and fresh air processing unit can be connected to the same refrigerant system, increasingdesign flexibility and greatly reducing total system costs.

Healthy and comfortable

100% Fresh air processing unit

External static pressure can be up to 220Pa(125~140 models) and 260Pa(200~280 models) for more flexible ductapplications. The maximal distance of air supply is about 45.9ft.(14m) and the maximum height of air supply isabout 21.3ft.(6.5m).

High external static pressure

Innovative air supply technology for excellent room temperature control

Fresh Air Processing Unith Air Processing Unit

the longest distanceof air supply is 14m

The height of airsupply is 6.5m

INDOOR UNIT

Fresh air in take

nruter riAylppus riA

Layout Example:

Indoor Unit Indoor Unit

Outdoor Units

Outdoor Air processing unit

Air-conditioning Fresh air supply

Notes:

1. Nominal cooling capacities are based on the following conditions: outdoor air temperature:91.4°F(33°C)DB,75.2°F(24°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).

2. Nominal heating capacities are based on the following conditions: outdoor air temperature:32°F(0°C)DB,30.2°F(-1°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).

3. Sound level is measured 4.59ft.(1.4m) from the air out-let.

* External static pressure are based on high speed indoor airflow.

* Specifications are subject to change without prior notice for product improvement.

* When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units.

* When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units.

* Outdoor-air processing units can be used without indoor units.

* The fresh air processing unit is not available for V4+R system.

Connection Conditions:The following restrictions must be observed in order to maintain the indoor units connected to the same system.

Model

208~230V-1Ph-60Hz

R410A

EXV

Wired controller KJR-29B1/BK-E (6m wrie is standard)

OD 1-17/64( 32)

Power Supply

Capacity

ESP (external static pressure)

Sound pressure level(H/M/L)

Net dimension

Standard Controller

Indoor air flow (H/M/L)

Refrigerant

Piping Connections

Cooling

Heating

Type

Control method

W×H×D

W×H×D

1,568/1,452/1,352

923/855/796

50(30~ 196)

54/52/50

1,568/1,452/1,352

923/855/796

50(30~ 196)

53/50/48

4,429/3,884/3,332

2,607/2,286/1,961

140(50~250)

54/53/51

4,560/4,083/3,563

2,684/2,403/2,097

140(50~250)

55/54/52

4,939/4,405/3,859

2,907/2,593/2,271

160(50~250)

55/54/52

56-17/32×17-23/32×30-1/4(1,436×450×768) 59-13/32×21-21/32×38-31/32(1,509×550×990)

L(flare)

G(flare)

Drain piping

kW

kcal/h

Btu/h

kW

kcal/h

Btu/h

m3/h

CFM

Pa

dB(A)

lbs.(kg)

in.(mm)

in.(mm)

in.(mm)

-

12.5

10,800

42,600

10.5

9,000

36,000

468

468

2.3

2.3

14

12000

47,800

12

10,300

41,000

468

468

2.7

2.7

20

17,200

68,200

18

15,500

61,400

616

616

6.6

6.6

25

21,500

85,300

20

17,200

68,200

616

616

6.6

6.6

28

24,100

95,500

22

18,900

75,000

616

616

6.6

6.6

AF-1NV/1T082D-VDYAF-1NV/1T052D-VDYAF-1NV/1T002D-VDYAF-1NV/1T521D-VDY YDV-D140T1/VN1-FA

Net/Gross Weight

Packing dimension

in.(mm)

in.(mm)

153.2/167.5(69.5/76)

3/8( 9.53)

5/8( 15.9)

153.2/167.5(69.5/76)

3/8( 9.53)

5/8( 15.9)

47-1/4×15-3/4×23-5/8 (1,200×400×600)

254/284(115/129)

3/8( 9.53)

5/8( 15.9)

254/284(115/129)

3/8( 9.53)

5/8( 15.9)

254/284(115/129)

3/8( 9.53)

5/8( 15.9)

56-1/8×19-11/16×36-17/32 (1,425×500×928)

Power input

Rated current

Cooling

Heating

Cooling

Heating

W

A

Indoor Units Lineup

Indoor Units Lineup

Page 44: R410A DC Inverter VRF Series 60Hz-YONAN

Note: The wires in the diagram show the signal flows only, while not represent the actual connecting ways.

Individual controlCentralized Control

Accessories

KJR-10BKJR-12BKJR-90AKJR-29B

RM02RM05R05R06R51R71

Card-key Interface MD-NIM05

Remote controller

Wired controller

Outdoor units

Network Control

Control Systems

Card-key

Wired controller

Wired controller

Indoor Centralized Controller(Touch key)

MD-CCM08

Data converterCCM15

Modbus gateway

Connectable tovarious sized Gateway

BACnet BMS

Web monitoring system

Modbus BMS

M-INTERFACE GatewayIMM Software

potpaLdaPi

MD-LonGW64Lonworks BMS

Outdoor Centralized Monitor

K1,K2,E

Indoor Centralized Controller

X,Y,E

X,Y,E

F1,F2,E

MD-CCM02

MD-CCM03

CCM30

89 90

Infared Sensor MD-NIM09

Infrared control box

Infrared sensor module

MD-NIM05

KJR-86CKJR-120AKJR-90C

Control S

ystem

Control S

ystem

Page 45: R410A DC Inverter VRF Series 60Hz-YONAN

Comparison of Controllers

Portable device

Background light

Simplified user interface

Built-in timer

Setting addresses

Functions

Wireless Remote Controller

20MRledoM

150×60×15

R51

140×60×15

R71

125×42×27

1.5V(LR03/AAA)×2

R05

150×65×20

R06

100×55×20

RM05

150×65×20

Temp

ON/OFF

Time ON/OFF

Fan speed

Transmitting display

Lock

Running mode

Economic operation

1

2

4

7

8

3

6

9

Time5

ON OFF

0 3 6 9 12 15 18 21

24°C

Time

R51 R71R05 R06RM05

FFONO

The indoor unit is set to work in automode from 8:00 to 20:00

RM02

: Available controller functions: Not available controller functions

Specifications

Users can synchronize the air conditioners’ param-eters with the display panel on the wireless remotecontroller to precisely control a room's environment.

Dimensions (H×W×D)(mm)

Power (V)

The wireless remote controller is a portable controldevice that enables users to control the A/C any-where within a distance of 11m.

The background light allows users to operate the device in a dark room. The device lights up when a button is pressed, and turns off when a given opera-tion is completed.

The built-in daily timer offers the convenience of auto-matically starting and stopping the system at set times.

Besides the machine’ s auto addressing function, users can set the indoor unit’ s address onthe wireless remote controller RM05/RM02.

91 92

1 1 1 1 64 64 16

On/Off

MAX. controllable IDU

Operation mode setting

Fan speed setting

Room temp. setting

Vertical swing

Horizontal swing

Air direction

Economic mode

Central setting

Keyboard lock

Mode lock

Remote signal receiving

26 shortcut setting

Silent mode

Backlight

Current time

RC prohibition

Address

Error code

Room temp.

Period Week

On/Off per day 4

On/Off per week 28

On/Off timer

FOLLOW ME

Emergent stop

Emergent start

Address setting

BMS access

Control via internet

Air filter cleaning reminding

Control

/

Display

Timer

A/C control

function

-

-

/- /- - - - - - - -

/- -

/- -/ - - - - - - -

/- - - - - -

- - - - - - -

/- - -

- - - - - - - -

- - - - - - - - -

-/ - - - - -/ - - - -

- - - - - - - - -

/- /- -/

/- - /- /- - - -

- - - - - - - -

- - - - - - - -

- - - - - - -

------

- - - - -

-

- - -

- -

-

---------

---------

/- -

-/ - - -/ - - - - -

- - - - - - - - -

- - - - - - - - -

- - - - - - - -

- - - - - - - - -

- - - - - - - - -

- - - /- - /- - -

RM05/RM02

R51/R71

R05/R06

KJR-10B/KJR-12B KJR-120A KJR-90A

/KJR-86C KJR-29BKJR-90C

CCM30/MD-CCM03 MD-CCM09 KJR-

90B

Centralized ControllerItem

Model name

rellortnoC deriWrellortnoc etomeR

-/

AUTO

Auto mode COOL modeDRY mode HEAT mode FAN mode

Eco modeLock Address setting Follow MeTimer

*The follow me function is available for RM02 Control S

ystem

Control S

ystem

Page 46: R410A DC Inverter VRF Series 60Hz-YONAN

Functions

Wired Controller

90C

86×86×16.5Dimensions (H×W×D)(mm)

Power (V)

Model 29B

120×120×20

DC 5V

Specifications

Under the cooling, heating and auto mode,when oper-ate the silent mode, it can reduce the running noise through setting the fan speed to low. This will help you bring a quieter environment.

Silent mode

Air filter cleaning reminding icon

Remote signal receiver

Silent KeyKJR-29B

(Touch key)

Remote signal receiving function KJR-29B and KJR-90C provide a signal receiver for remote controller. Signal from remote controller can be received by a wired controller, then sent to the indoor unit and it conveniences to control.

93 94

KJR-29B KJR-90C

AUTO

Auto mode COOL modeDRY mode HEAT mode FAN mode

gnittes sserddAkcoL Follow MeTimer Filter cleaning remind

Air filter cleaning reminding

The wired controller records the total running time of the indoor unit. When the accumulated running time reaches the pre-set value, it will remind users need to clean the air filter of the indoor unit. Clean the filter regularly can keep indoor air fresh and clean, good for your health.

*Available for KJR-10B/KJR-29B/KJR-90C model.

Easy connection

The wired controller conveniently connects to the indoor unit’ s display panel via connecting wire.

Wired controller

Indoor main board

Display panel

Functions

Setting addresses

With the address setting function,and easy for the installation and future service. The service person can set the address for indoor unit by KJR-10B, KJR-29B and KJR-90C.

Wired Controller

Dimensions (H×W×D)(mm)

Power (V)

Model 10B

120×120×15

DC 5V

12B

120×120×15

Specifications

Follow me

With the FOLLOW ME function, the wired controller can detect the air temperature at the user’ s altitude instead that of the ceiling or floor. This helps making the room environment comfortable and the tempera-ture accurate.

*The follow me function is available for KJR-12B/KJR-29B model.

Sensor part

FOLLOW ME Button

B21-RJK B01-RJK

Built-in timer

0 3 6 9 12 15 18 21

24°C

Time

FFONO

The indoor unit is set to work in automode from 8:00 to 20:00

Built-in daily timer offers the convenience of automati-cally starting and stopping the system at set times.

AUTO

Auto mode COOL modeDRY mode HEAT mode FAN mode Silent mode

gnittes sserddAkcoL Follow MeTimer Filter cleaning remind

The locking function can be used to prevent other people from using the controller.

Locking wired controller

Wired controller

Control S

ystem

Control S

ystem

Page 47: R410A DC Inverter VRF Series 60Hz-YONAN

Model

DC 5V

86C

86×86×18

120A

120×120×20

Specifications

Dimensions (H×W×D)(mm)

Power (V)

90A

90×86×13

Wired Controller

Functions

Features

KJR-90A KJR-86C KJR-120A

Built-in timer

Combination key Selecting mode

26°C Shortcut setting

Auto mode

Mode settingMode-button hidden controller :Press the temperature buttons " " and " " simultaneously for 3 seconds to select the opera-tion mode: COOL and HEAT. The design is suitable for hotels, hospitals, schools and other similar types of buildings.

For V4 plus R series used only. Under the auto mode of V4 plus R system, it can automatically switch to COOL or HEAT mode according to the temperature difference value between Tf(indoor temperature) and Ts(setting temperature)

KJR-90A

KJR-86C

Built-in daily timer offers the convenience of automatically starting and stopping the system at set times.

95 96

KJR-120A

Dimensions(H×W×D)(mm)

Power (V)

120×120×15

198-242V(50/60Hz)

Model KJR-27B

Specifications

FunctionsHRV controllerKJR-27B is individually designed for HRV—Heat Recovery Ventilator. The HRV can work in the following modes: exhaust, air supply, bypass, heat exchange, and auto.

Built-in timerBuilt-in daily timer offers the convenience of automatically starting and stopping the HRV at the set times.

KJR-27B

0 3 6 9 12 15 18 21

24°C

Time

ON OFF

Setup screen exampleSet to wednesday: 8:00 to 20:00

AUTO->HEAT EXCHANGE->EXHAUST->BYPASS->AIR SUPPLY

Wired ControllerHRV Wired Controller

120×120×15

DC 5V

Model MD-CCM04

Functions

MD-CCM04

Weekly Schedule Controller

Dimensions (H*W*D)(mm)

Power (V)

Functions

Weekly schedule

Specifications

Sun

Mon

Tue

Wed

Thu

Fri

Sat

22°C

22°C

off

8:00 16:00 23:5928°C

26°C

26°C

26°C

26°C

26°C

28°C

22°C

22°C

22°C

17°C

17°C

17°C

23°C

23°C

23°C

26°C

26°C

24°C

22°C 24°C

Users can set up to 4 periods per day, and select the desired running mode and room temperature.

MD-CCM04 can be used as a weekly schedule wired controller or general wired controller. It can query the indoor temperature and the setting parameters of the weekly schedule. It can display the error codes and running state of the indoor unit. With the LCD backlight, and allows users to operation the device in a dark room.

Delay function

Simple disign

The function is specially designed for a person who is working overtime. During the weekly schedule running, press delay button it will delay 1hour or 2 hours to turn off the air conditioner.

Control S

ystem

Control S

ystem

Page 48: R410A DC Inverter VRF Series 60Hz-YONAN

Functions

sedom kcol eerhTlortnoc dezilartneC

The centralized controller is a multifunctional device that can control up to 64 indoor units within a maximum connection length of 1,200m.The device connects to the master outdoor units of Midea's newly designed products to simplify and centralize the wiring configuration. The two connection modes are as follows:

Centralized controller provides a superior way to manage the indoor units. Users are able to make their own choice from locking the wireless controller, locking the running mode or lock the centralized controller's keyboard as they wish.

Air filter cleaning reminding function

The air filter cleaning reminder function is only available on the touch-key central controller CCM30. The "FL" icon indicates that the air filter in a given indoor unit needs cleaning.

Indoor unit working status display

The centralized controller displays indoor units' working status and error codes so users can easily identify faults via checking the error codes table in the user's manual before contacting a service engineer.

X,Y,E

X,Y,E X,Y,E X,Y,E X,Y,E

P,Q,E P,Q,E P,Q,E

HEAT mode

Keyboard lock

Indoor Centralized Controller

Centralized Controller

MD-CCM03 CCM30

LockingKeyboard

kingboard

LockingRunning

Mode

kingning

ode

Locking Remote

Controller

king motetroller

(1.6

)

Error code or protection code

Connectingstatus matrix

GROUP QUERY RUN SET

SET.TEMPROOM.TEMP

#GROUPALL

INLINE ON OFF

rHrH ON

T3 OFFT2AT2B

ERRORPROTECT

MODE

FAN

AUTO

OPR.UNSUCCESS

00+

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16

16+

32+

48+

#Air filter cleaning reminding icon

CCM30

9897

Stylish design

Easy installation

Model

FunctionsSingle/unified control

CCM's stylish design suits high-end environments. The keyboard lock function is used to prevent operational mistakes.

Centralized controller offers two different appearances to mostly suit the installation. The A structure must be embedded into the wall and the B structure doesn’ t need. Both of them are easy to operate.

The control object can be either a single unit or all units, which vastly simplifies the control process. Operation signal feedback ensures that all units are working in the correct mode.

B structure leading-out mode sketchB tB stB st tructructureure l dleadleadiing-ing toutout dmodemode kskesket htchtch

Rear side outlet

Under side outlet

Upper side outlet

A

B

*The A,B structure is available for CCM30,and MD-CCM03 only has B structure

Access to network monitoringThe centralized controller is able to bridge up to 64 indoor units on the network monitoring and building management systems.

Model MD-CCM03

SpecificationsIndoor CCM

MAX.64

198-242V(50/60Hz)

179×119×74 180×122×78 and 180×122×68

CCM30

Dimensions (H*W*D)(mm)

Power (V)

X,Y,E F1,F2,E

OPR.UNSUCCESS

Remote controller lock

COOL mode Swing Filter cleaning remind

Timer Fan mode

Cooling lock Heating lock Net connection

Net

R

Control S

ystem

Control S

ystem

Page 49: R410A DC Inverter VRF Series 60Hz-YONAN

99 100

Single/unified control mode

Functions

Weekly schedule

Three lock modes

Indoor unit working status display

Weekly Schedule Centralized Controller

Centralized Controller

YD-CCM09

Sun

Mon

Tue

Wed

Thu

Fri

Sat

22°C

22°C

off

8:00 16:00 23:5928°C

26°C

26°C

26°C

26°C

26°C

28°C

22°C

22°C

22°C

17°C

17°C

17°C

23°C

23°C

23°C

26°C

26°C

24°C

22°C 24°C

OPR.UNSUCCESS

(1.6

)

Error code or protection code

Connectingstatus matrix

GROUP QUERY RUN SET

SET.TEMPROOM.TEMP

#GROUPALL

INLINE ON OFF

rHrH ON

T3 OFFT2AT2B

ERRORPROTECT

MODE

FAN

AUTO

OPR.UNSUCCESS

00+

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16

16+

32+

48+

#

AUTO

Auto mode COOL mode HEAT mode Fan mode

Swing Keyboard lock

Remote controller lockHeating lock

Cooling lockDRY mode

179×119×74

198-242V(50/60Hz)

Model YD-CCM09

Specifications

LockingKeyboard

kingboard

LockingRunning

Mode

kingning

ode

Locking Remote

Controller

king motetroller

Dimensions (H*W*D)(mm)

Power (V)

YD-CCM09 can include up to 64 indoor units in the weekly schedule. Users can set up to 4 periods perday, and select the desired running mode and roomtemperature. The operating object can be a singleindoor unit or all the indoor units.

Centralized controller MD-CCM09 provides a supe-rior way to manage the indoor units. Users are able to make their own choice from locking the wireless controller, locking the running mode or lock the MD-CCM09’ s keyboard as they wish.

YD-CCM09 displays indoor units' working status and error codes so users can easily identify faults via checking the error codes table in the user's manual before contacting a service engineer.

The control object can be either a single unit or all units, which vastly simplifies the control process. Op-eration signal feedback ensures that all units are working in the correct mode.

Weekly schedule

Unified On/Off Controller

FunctionsUnified control

Centralized controlKJR-90B can be used to centrally control up to 16 indoor units.

Light indicator

Easy installationKJR-90B can be easily mounted on the built-in cabinet:

Unified controller design with graceful appearance and explicit panel.

Centralized Controller

Single On/Off key

Unified On/Off key

eulBthgiL

Cooling/Fan

Red

Heating

Flash

IDU Error

EEPROM Error

90×86×8

DC 5V

Model KJR-90B

Specifications

KJR-90B

20°C0 Ccooling

28°Cheating

Max.16

Dimensions (H*W*D)(mm)

Power (V)

KJR-90B offers on/off and heating/coolingfunctionality for indoor units based on preset temperatures to ensure easy management.

The LEDs on KJR-90B indicate the indoor units' running status for easy fault detection. The lights switch off automatically to save energy once a given operation is complete. The indicators are as follows:

Control S

ystem

Control S

ystem

Page 50: R410A DC Inverter VRF Series 60Hz-YONAN

101 102

Central Control Software

PC SMS modem

Laptop Router

M-interface web gateway

Power ammeter

Outdoor units Indoor units

IMM Software

Web Access

IMM Gateway

A/C Systems

Pad

Functions

Access to network monitoring

YD-CCM02Outdoor Centralized MonitorCentralized Monitor

With the ODU communication

With the PC communication

Forced Cooling

Forced Cooling

Graph 2 LCD Screen

Forced Cooling

YD-CCM02 can connect up to 8 refrigerant systems and 32 outdoor units to the network system.

Max.4

Max.4

Max.4

Max.32 K1,K2,E

K1,K2,E

K1,K2,E

system 1

system 2

system 8

120×120×15

198-242V(50/60Hz)

Model YD-CCM02

Specifications

Dimensions(H×W×D)(mm)

Power (V)

YD-CCM02 enables users to easily check outdoor units' running status, including frequency, temperature, current, pressure, protection codes and error codes.

ODU parameters display

Query parameters

Protection/Error codes

4-way/EXV valve

Power consumption

Control S

ystem

Control S

ystem

Page 51: R410A DC Inverter VRF Series 60Hz-YONAN

Simple Operation and Management Click & Operate, a user-friendly interface allows even non-experts to perform the building management system easily.

Data ManagementOperational information of individual indoor units are monitored, allowing for distribution of power consumption at outdoor units.Stores operation data on multiple systems and displays it in graphical format for visual management.Uses IMM software to generate tenant reports and help building owners bill for energy use.

Electricity Charge Distribution(Patented)Provides information on proportional electrical power distribution to optimize electricity consumption management.

Uses software to calculate electric power proportional distribution, output and save electricity consumption data for each indoor unit (or group) which is connected to the intelligent manager.Applies the patented Midea Calculation Method to calculate consumption rates according to capacity demand which is based on various parameters: setting temperature, room temperature, running mode, rated HP, public areas, unused rooms, and nighttime use; outputs this information on a charge calculation sheet to evenly divide power consumption charges among tenants.

Hightlights

Various Managements

Web Access functionWith the web access function, a PC, laptop com-puter or a smart phone can be used as a remote controller.

Energy Saving ManagementBased on a predetermined schedule, the Intelligent Manager executes capacity control and intermittent operations on all air conditioning units to maintain a high comfort index.

Schedule ControlAutomatically performs facility start/stop control, switches the operating mode, sets temperatures and enables/disables the remote control according to the present time schedule. 4 sections and 20 actions per day for each single unit or group.

Visual NavigationClicking the jump button will display a list of all avail-able screens. Clicking the back button will return to the previous screen.

Warning Message

Data Backup

Multiple Languages

Electricity Charge DistributionThe system can receive error messages from air conditioning units in more than one buildings or structures via public phone lines. *Requires the Midea "SMS Modem" to send auto-matic warning messages to designated phone num-bers.

The M-interface will automatically back up data on the installed SD card (2GB) in case system failure occurs, such as: power failure or system dam. IMM software also stores the previous 3 months' operational data on the HDD.

English

Russian

French

German

Italian

Spanish

Provides seven language settings:

Electricity charges can be easily divided when billing users for air conditioning power charges; for example, for tenants in a commercial building, offices in a rented building, or rooms in a hotel.

Simple Chinese

IMM(Intelligent Manager of Midea)4th Generation Network Control System

Central Control Software

FunctionsIntelligent Manager of Midea, designed specifically to control VRF systems, is based on a centralized format and dedicated to the complete control and monitoring of all the system’s functions. It can be used as a flexible multi-purpose system and applied to a variety of needs, according to the scale, purpose and control method of each building.

Annual schedule controlUp to 4 M-interfaces, 64 refrigerant systems, 1,024 indoor units, and 256 outdoor units can be controlled by one PC.Web Access

User friendly operation

Central building monitoring and control

Energy saving management

SMS modem (optional)

Electricity charge distribution

Low-load operation indicate

Generate operational history reports (daily, weekly, monthly)Fault display & Warning message

Filter replacement reminder

Emergency stop and Alarm signal output

Network Control Application

Can run on ,Window 7_64 bi t and Window XP_32 bit.Can monitor and control A/C anytime, anywhere by PC, iPhone, iPad and notebook computer.Support WEB access: IE, Firefox, Safari and Chrome.Enables remote access through DSL, VPNs and so on.

Max.IDU:1024

dow 7_64 bi t and

ontrol A/C anytime, iPhone, iPad and

ss: IE, Firefox, Safari

ccess through DSL,

Max IDU:1024

Control S

ystem

Control S

ystem

103 104

Page 52: R410A DC Inverter VRF Series 60Hz-YONAN

105 106

Accessories Weekly schedule control

Web features

Intelligent control

Network example

Simply control interface

Data converter CCM15

Can realize data conversion between TCP/IP protocol and 485 protocol.

WEB function realizes VRF system's webpage access.

User can monitor and query the air conditioners through LAN and WAN.

Providing the TCP / IP port for VRF system of Midea to achieve WEB/HTTP/TCP/IP access.

Can remotely control the A/C systems through computer, iPhone, iPad or other intelligent terminals.

Can be directly connected with XYE port of the indoor units.

Up to connect 64 indoor units.

CCM03/CCM30 is optional and can be connected with CCM15 through F1, F2 and E ports.

The system consisting A/C system, data converter CCM15, router, cloud server and control terminal.

Software control/ Cloud server control (WEB access).

Click & operate, a user-friendly interface.

Allows signal and group control.

Simplified user control interface.

Colour indication and icon makes it easy to recognize unit state.

Can full screen display and the temperature can be adjusted by fingers' sliding.

With weekly schedule function for iPad.

Multiple sections in each day for single unit or group.

Automatically performs facility start/stop control, operating mode, setting temperatures and according to the

present time schedule.

Query and control single unit or group.

Weekly schedule setting: can set multiple sections in each day for single unit or group.

Group user control : a user can use the same ID to manage hundreds of CCM15,

when selecting the "As group user" button on the login page.

History error: easy service and management with history error function.

The air conditioner remote control can be realized by mobile phone or tablet computer.

You can query the running state of the air conditioner any time and any where and even make an

appointment in advance.

Can remotely turn off the air conditioner to avoid the power waste, when you are in a hurry to leave.

Iphone

Router Indoor units

CCM15PC

X Y E

Max.64LAN

Cloud Servers

F1 F2 E

Optional

CCM30

Control S

ystem

Control S

ystem

Page 53: R410A DC Inverter VRF Series 60Hz-YONAN

Config A/C System via Web Dimensions

Network ExampleNetwork example

Supports Modbus protocol networksBridges the Midea central A/C system and the BMSEstablishes a Modbus network comprising up to 1,024 indoor units and 64 outdoor unitsTransfers data in RTU modeProvides a wide voltage range: 12-48V DC

Modbus BMS Gateway

When the Modbus network is set, users can conve-niently configure their A/C network system over the Internet using different TCP/IP browsers.

The Modbus Gateway is designed with a small size. It’s equipped a installation track for the easy on-site installation.

One Modbus gateway can bridge one refrigerant system with a PC or the Modbus master.

CCM02

CCM30

Outdoor Units

Indoor Units

ModbusGatewayModbus Master

ModbusGateway

ModbusGateway

Max.64

Max.64

Max.64

Max.16

CCM02

CCM30

CCM02

CCM30

ediS tnorFediS thgiR

110

46

354836

100

10.5

25.5

10.5

Installation Track

P,Q,E

X,Y,E

X,Y,E

P,Q,E

P,Q,E

F1,F2

F1,F2

K1,K2,E

K1,K2,E

K1,K2,E

K1,K2,E

F1,F2,E

Accessories

Network example

Monitoring units online

RS485

Contains 4 groups of RS485 communication ports and be able to connect up to 256 indoor units or 128 outdoor units to the BMS.Be free to connect to the BMS or not.

YD-CCM08 allows users to track units' operational status and change their running parameters on Internet Explorer for maximum control convenience

BACnet® BMS Gateway Accessories

YD-CCM08

Wide compatibilityCCM08 has a wonderful adaptability to the BMS

erawtfos SMBynapmoC

1

2

3

4

5

SIMENS

TRANE

Honeywell

Schneider

Johnson

Brand

APOGEE

Tracer Summit

Alerton

Andover

METASYS

APOGEEA N Y W H E R E

TM

TRACER SUMMT

BMS

Outdoor units

Outdoor units

Indoor units

BACnet/IP protocol

ts

CCM30

CCM30

TCP/IP

YD-CCM08

RS485

CCM02

Web monitoring system

HUB

Indoor units

One YD-CCM08 gateway can connect MAX.4 CCM02 or CCM03,and each 485 port only can connect one CCM02 or one CCM03/CCM30.

Modbus agreement system

A+,A-,GND

Control S

ystem

Control S

ystem

107 108

Page 54: R410A DC Inverter VRF Series 60Hz-YONAN

Specifications

230×145×72

200V-500V(50/60Hz)

Model DTS634/DTS636

Specifications

Indications and installationLow power consumption

Digital Power AmmeterDTS634/DTS636

15mm long crack

201

230

131145

A phaseB phaseC phase

LCD

72

Impulse

The protector protects the entire system from power supply problems, and auto restart after recovery.

Excellent reliability

3-Phase Protector HWUA/DPB71CM48

AccessoriesAccessories

Compliance with LonMark protocol,and realizes the management and control of A/C.Can connect up to 64 indoor units to the BMS.Realizes non-polarity communication,and also the application can be download online.

LonWorks® BMS Gateway

Network example

YD-LonGW64

Dimensions (H*W*D)(mm)

Power (V)31.9×25.1×6.1

177~265V AC(50Hz/60Hz)

Model YD-LonGW64

Specifications

Dimensions (H*W*D)(mm)

Power (V)

HWUA DPB71CM48

Detect the power condition and make the corresponding protecting action.Protect the compressor from being damaged. Automatically distinguish the abnormal power supply conditions and automatically recover.

Calculates power consumption. Does not need adjusting after long-term use.Corresponds one outdoor unit to one digital power meter.

The digital power meter consumes mini-mal energy.Voltage circuit: less than 2W/10VACurrent circuit: less than 2.5VA

The digital power meter is tested after manufacture so it can be immediately deployment and used on-site. The LED indicators and installation schematic are shown in the figure on the left.

Without over/under voltage function

HWUA DPA53CM23 HWUA DPB71CM48 DPA51CM44

Power supply (V-N-Hz) 220~480V-3N 50/60Hz

-20 C~50 C50Hz: -20 ~6060Hz:-20 ~50 -20 ~50 -20 ~50 50Hz: -20 ~60

60Hz:-20 ~50

208~480V-3N 50/60Hz 220~480V-3N 50/60Hz 380~480V-3N 50/60Hz 208~480V-3N 50/60Hz

Temp. range( C)

Rated operational power(VA) AV 31AV 31AV 9.2AV 7AV 9.2%81%81%21%21egatlov revO

%21-%21-%21-%21-egatlov rednU

%8%8/%8 ecnalabmi esahP

Dimensions(W×H×D)(mm) 90×69×35 81×67.2×17.5 90×69×35 81×67×35 81×67.2×17.5

ModelWith over/under voltage function

/

C CCC C C C C C

CCC

Connection method 1: Suitable for all of air conditioner systems and connect max.64 indoor units.

Connection method 2: Only suitable for V4 plus system and connect max.64 indoor units.

YD-LonGW64/E

BMS system

X,Y,E

X,Y,E X,Y,E X,Y,E X,Y,EP,Q,E

P,Q,E

P,Q,E

RS485

System 1

System 2

System N

X,Y,E X,Y,E X,Y,E X,Y,ERS485

YD-LonGW64/E

BMS system

Control S

ystem

Control S

ystem

109 110

Page 55: R410A DC Inverter VRF Series 60Hz-YONAN

Installation example Electrical wiring

Cooperate with the wired controller to automate control. Eliminates the need for high voltage power, making the device safe and steady.Includes a build-in auto-restart function.

Hotel Card Key Interface Module YD-NIM05

Dimensions (H*W*D)(mm)

Power (V)

86×72.8×15.5

DC 5V

Model YD-NIM05

Specifications

220V

Card key

AC contactor

KM

Wired controller

Installation example

MD-NIM09 works together with the wired controller.

Automatically adjust the room environment.Automatically extend the shutting down time, avoiding frequent ON/OFF.Graceful appearance accommodates itself to different buildings.

YD-NIM09Infrared sensor controller

Dimensions(H×W×D)(mm)

Power

Senor part: 46×30×25.6, Control box: 86×72.8×15.5

DC 5V

Model YD-NIM09

Specifications

Accessories

Wired controller is necessary in this card-key system.

Card key

MD-NIM05MD-NIM05MD NINNNNN M05

Wired controller

Wired controller

rellortnoc deriWrellortnoc deriW

MD-NIM09 MD-NIM0909

System wiring diagram

Functions

Simple design

KJR-150AIndoor Unit Group Controller

Specifications

150×85×70

198-242V(50/60Hz)

Model KJR-150A

Dimensions (H*W*D)(mm)

Power (V)

FunctionsSimple design

KJR-32BRemote Alarm Controller

Specifications

150×85×70

198-242V(50/60Hz)

Model KJR-32B

Dimensions (H*W*D)(mm)

Power (V)

KJR-32B is specially designed for engineering applications. It does not display the ODU’s working parameters, but it can connect to the alarm device when ODU is working abnormally, the RUN light will flash.

KJR-150A is specially designed for V4 plus indoor units. A group controller can connect up to 16 V4 plus indoor units through X1, Y1 and E terminals, but it cannot directly connect to the central controller. If you need to use a central controller or a PC, you can connect to the XYE from an outdoor unit. A group controller can control a group of indoor units simultaneously, and query the running status of each unit in the group via the display panel.

Centralized controller

XYE

NOTE :The Maximum Number of Indoor units is 64.

V4+ Outdoor UnitPQE

PQE

X Y E X Y E X Y E X Y E X Y E

X Y E X Y E X Y E X Y E X Y E X Y E

N( #N tinu roodni +4V )#1(tinu roodni +4V 16)V4+ indoor unit (2#) V4+ indoor unit (3#)

N( #N tinu roodni +4V )#1(tinu roodni +4V 16)V4+ indoor unit (2#) V4+ indoor unit (3#)

KJR-150A1#

KJR-150A16# POWER

Control S

ystem

Control S

ystem

111 112

Wired controller

S1

Infrared sensor controller

Infrared sensor

Infrared inductive control box

Indoor main board

Display panel

CN3CN2CN1MD-NIM09/E

Network module port Display panel port

Remote controller

Electrical wiring

Page 56: R410A DC Inverter VRF Series 60Hz-YONAN

K1,K2,E485A-I

Wiring diagram

CPU

HDD

Interface port

Pentium 4 2G or above

30G free space

RS-232 terminal

Operating system WIN XP SP4/WIN 7

Recommended config

335×375×150

220-240V~ 50Hz 208-230V~ 60Hz

A30-ZKUHA/A20-ZKUHA/A10-ZKUHAledoM

Specifications

IntroductionAHUKZ-01A/AHUKZ-02A/AHUKZ-03A is an independent control box that can connect a AHU to V4 plus system to realize centralized control with V4 plus system. Control box wiring is as follows:

AHUKZ-01A/AHUKZ-02A/AHUKZ-03AV4+ functions inside.Can be used to connect VRF outdoor units with DX AHU or other brand indoor units

Display the outdoor units’ real-time running conditions.Automatically outputs running status charts.Supports V3, V4, V4+, D3, D4 outdoor units.

The diagnostic software applies to K1, K2, E of the outdoor units. The corresponding wiring diagram is shown in the figure on the right.

Midea Outdoor Unit Diagnosis Software MCAC-DIAG/E

AHU Control BoxAccessories

Dimensions(H×W×D)(mm)

Power (V)

T1/T2/T2B/T2C

Fan/pump

Centralized Controller

Wired Controller

P/Q/E X/Y/E

G/L pipe

Power supply Power supply

Power supply

DX AHU or other brand indoor units

x EXV

Selection software

Windows Version

CAD Version

To meet consultants’ and distributors’ requirements, Midea has developed an advanced design automation tool that can be used in AutoCAD-based CAD version or Windows-based Sales version. The software provides quick and convenient selectable options for users, supports multiple languages, and greatly improves the selection process.

Load calculation:Provides two calculation methods (detailed room load calculation and rough load calculation).Indoor & outdoor units selection: There are versatile indoor units and different outdoor units for choosing.Piping drawing: Displays the detailed layout of an A/C system and the parameters for piping and branch distributors.Controller selection: Provides a selection of controllers for indoor units and outdoor units, including wireless and remote controllers for indoor units.Report output: Outputs a comprehensive selection report as a Word or PDF document.

AutoCAD add-on softwareAutomatic Calculation: Refrigerant & drain pipe sizeAutomatic Selection: Distributor kit & branch jointSystem Check: Installation regulation & refrigerant additionAutomatic Report: Piping installation diagram, equipment list & quotation

Control S

ystem

Control S

ystem

113 114

Page 57: R410A DC Inverter VRF Series 60Hz-YONAN

115 116

When air flow formed by the fans goes through the heat exchanged core in cross way, due to temperature difference between two channels of the core, thermal transmission happens naturally.In summer days, high temperature outdoor air gets cooled by indoor exhaust air; in winter, low temperature outdoor air gets heated by indoor exhaust air. So the energy contained in exhaust air can be reclaimed and energy efficiency gets improved.

Multi-modes for different situationsHeat exchange mode

In mild climate areas or seasons, when temperature and humidity level difference between indoor and outdoor is small, the unit works as conventional ventilation fan. Both supply fan and exhaust fan works at the same speed (Hi/mid/low/auto).

It is one kind of bypass mode with air supply fan speed higher than exhaust fan speed. It can be used in mild climate area where large amount fresh air is needed.

It is also one kind of bypass mode with exhaust fan speed higher than air supply fan speed. It can be used in mild climate area where large amount exhaust air needs to be expelled.

The controller chooses heat exchange mode or bypass mode according to the temperature difference between outdoor and indoor temperature. Both the two fans work at low speed.

Interlocking control with other indoor units by controller is possible.

Flexible control

Bypass mode

Air supply mode

edom otuAedom ria tsuahxE

EA

OA

RA

SA

Element

Damper

Element

EA

OA

RA

SA

DamperThe heat recovery ventilator (HRV) can reclaim heat energy lost through ventilation and reduce the room temperature fluctuation caused by ventilation process. By utilizing the most advanced technology and technics, Midea HRV has extremely good performance. The heat exchanged core is made of special paper processed with chemical treatment, which could realize better temperature and humidity control of the room environment. Temperature exchange efficiency is above 65% and enthalpy exchange efficiency between 50-65%.

Heat recovery ventilatorLarger air supply rateenhanced heat exchange efficiencyenhanced energy saving property HRV-400

HRV-500HRV-800HRV-1000

Model Names

With a min. height of only 10-25/64in.(264mm) and 50lbs(23kg) weight, the unit provides best convenience and possibility for installation in limited spaces.

Sound proof material is used to guarantee quiet operation.

Low noise

Compact design, flexible installation and easy maintenance

HRV-1500 HRV-2000

SA14。C

6。C

0

。C

EA

Heat exchange plate

20°CWarm airHeat

0°CCold air

HeatMoistureuu

Moisture

(Exhaust air to outdoors)

(Fresh air from outdoors)

(Returm air from room)

(Supply air to room)

EA

OA

RA

SA

Heat exchange mode

Bypass mode

th other indoor units by controller is possible.

Duct (Obtain locally)

SASA

SASA

RARA

OA

IDUIDU

IDUIDU

EAEA

Centralized control

CCM03CCM03

HRV

HR

V

HR

V

10-25/64in.(264mm)

Page 58: R410A DC Inverter VRF Series 60Hz-YONAN

117

Note:1. For the units model of HRV (400-1000), there are 3-speed adjustable air volume (Hi, Med, Low), but for the units model of HRV (1500-2000), there are only 1-speed which cannot be adjusted.2. Sound level is measured at 1.4m below the center of the body in an anechoic chamber..3. Airflow rate can transmit between low mode and high mode4. Temperature Exchange Efficiency is the mean value between cooling and heating5. Efficiency is measured under the following conditions:

* Cooling Condition: Air Exhaust Temp. 27°C DB,19.5°C WB., Fresh Air Temp. 35°C DB,28°C WB

* Heating Condition: Air Exhaust Temp. 21°C DB,13°C WB., Fresh Air Temp. 5°C DB,2°C WB

Branch Pipe

HR

V

SpecificationsV/Ph/Hz

%%%%%%%%%

dB(A)dB(A)dB(A)dB(A)dB(A)dB(A)mminch

kg(ibs)

m3/h(CFM)m3/h(CFM)m3/h(CFM)Pa(in.WG)Pa(in.WG)Pa(in.WG)

Wmm(in.)

°C°F

For cooling

For heating

Heat exchange mode

Bypass mode

TypeAirflow rate

ESP

Motor output

HighMediumLowHighMediumLowHighMediumLowHighMediumLowHighMediumLow

HighMediumLowHighMediumLow

HRV-400220/1/60

656570505055606065323125333227

944×927×27037.2×36.5×10.6

31(68.3)

400(235.6)400(235.6)300(176.7)

80(0.32)65(0.26)43(0.17)

80144(5-5/8)

HRV-500220/1/60

656570505055606065353428363530

1038×1026×27040.9×40.4×10.6

41(90.4)

500(294.5)500(294.5)375(220.8)

80(0.32)68(0.27)45(0.18)

120194(7-5/8)

HRV-800220/1/60

656570505055606065393832403934

1286×1006×38850.6×39.6×15.3

62(136.7)

800(471.1)800(471.1)600(353.4)

100(0.4)82(0.33)54(0.22)

360242(9-1/2)

ModelPower supplyTemperature exchange efficiency

Enthalpy exchange efficiency

Sound pressure level

Dimension (W×D×H)

Gross weightCasingHeat exchange systemHeat exchange element materialFan

Duct diameterOperating temperature range

Galvanized steel plateAir to air cross flow total heat (sensible heat + latent heat) exchange

Specially processed nonflammable paperCentrifugal fan

-7~43 DB, 80% RH or less19.4~109.4 DB, 80% RH or less

V/Ph/Hz%%%%%%%%%

dB(A)dB(A)dB(A)dB(A)dB(A)dB(A)mminch

kg(ibs)

m3/h(CFM)m3/h(CFM)m3/h(CFM)Pa(in.WG)Pa(in.WG)Pa(in.WG)

Wmm(in.)

°C°F

For cooling

For heating

Heat exchange mode

Bypass mode

TypeAirflow rate

ESP

Motor output

HighMediumLowHighMediumLowHighMediumLowHighMediumLowHighMediumLow

HighMediumLowHighMediumLow

ModelPower supplyTemperature exchange efficiency

Enthalpy exchange efficiency

Sound pressure level

Dimension (W×D×H)

Gross weightCasingHeat exchange systemHeat exchange element materialFan

Duct diameterOperating temperature range

Galvanized steel plateAir to air cross flow total heat (sensible heat + latent heat) exchange

Specially processed nonflammable paperCentrifugal fan

-7~43 DB, 80% RH or less19.4~109.4 DB, 80% RH or less

HRV-1000220/1/60

656570505055606065403933414035

1286×1256×38850.6×49.4×15.3

79(173.8)

1000(588.2)1000(588.2)750(441.2)

1008558

360242(9-1/2)

HRV-1500220/3/60

65//

50//

60//

51//

52//

1600×1270×54063×50×21.3163(358.6)

1500(882.4)//

160//

450346×326(13-5/8×12-7/8)

HRV-2000220/3/60

65//

50//

60//

53//

54//

1650×1470×54065×57.9×21.3

182(400.4)

2000(1176.5)//

170//

450346×326(13-5/8×12-7/8)

Page 59: R410A DC Inverter VRF Series 60Hz-YONAN

119 120

Accessories

Accessories

Branch Pipe

For three outdoorunits connection

Branch joints of three-pipe refrigerant systemBranch joints of two-pipe refrigerant system

ecnaraeppAledoMPacking Size

in.(mm)DescriptionModel name

FQZHW-02N1D

FQZHW-03N1D

FQZHW-04N1D

FQZHN-01D

FQZHN-02D

FQZHN-03D

FQZHN-04D

FQZHN-05D

Branch joint for 410A outdoor unit

Branch joint for R410A indoor unit

A*:The total capacity of indoor units following this branch joint

10-1/16×5-7/8×7-1/4(255×150×185)

13-9/16×6-5/16×11-1/4(345×160×285)

18-3/4×6-1/2×11-3/4(475×165×300)

Description

11-7/16×4-1/8×4(290×105×100)

11-7/16×4-1/8×4(290×105×100)

12-3/16×5-1/8×4-15/16(310×130×125)

13-25/32×7-3/32×6-11/16(350×180×170)

14-3/8×7-11/16×8-15/32(365×195×215)

A*<16.6kW

16.6 A*<33kW

33kW A*<66kW

66kW A*<92kW

92kW A*

For two outdoorunits connection

For four outdoorunits connection

A*:The total capacity of indoor units following this branch joint

Gross Weight Ibs.(kg)

3.3(1.5)

7.48(3.4)

10.56(4.8)

0.88(0.4)

1.32(0.6)

1.98(0.9)

3.3(1.5)

4.18(1.9)

Branch joint between outdoor unit

Branch joint between MS unit and indoor unit

10-11/16×6-9/16×9-1/8

(272×167×232)

Branch joint between MS unit and outdoor unit

ecnaraeppAledoM Model name

FQZHW-03SB

FQZHW-02SB

FQZHN-01D

FQZHN-01SB

FQZHN-02SB

FQZHN-03SB

FQZHN-04SB

FQZHN-05SB

FQZHW-04SB

18-9/16×6-3/16×12-9/32

(472×157×312)

29-5/16×6-5/16×13-3/16

(745×160×335)

10-1/8×5×4-7/32

(257×127×107)

11-5/16×5-3/8×4-7/32

(287×137×107)

11-11/16×6-9/16×6-31/32

(297×167×177)

14-5/8×7-3/4×7-3/8

(372×197×187)

17-1/64×8-3/4×8-15/16

(432×222×227)

For two outdoorunits connection

For three outdoorunits connection

For four outdoorunits connection

Description

A*<16.6kW

A*<16.6kW

16.6 A*<33kW

33kW A*<66kW

66kW A*<92kW

92kW A*

Packing Size

in.(mm)

Gross

Weight

Ibs.(kg)

4.84(2.2)

11(5.0)

16.5(7.5)

1.76(0.8)

1.98(0.9)

3.08(1.4)

5.06(2.3)

7.26(3.3)

0.88(0.4)11-7/16×4-1/8×4

(290×105×100)


Top Related