SAT103 Technical Department Requirements
GROUP ASSIGNMENT REPORT
Submitted by:
Name NRIC/FIN
Vigneswari Venkatesan G3040633N
Date of Submission: 06 June 2015
Lecturer-in-charge: Thomas Lew
1. Nparks Parks Matters (30%) (a) Roadside Leafy Tree
Scientific Name: Samanea saman (Rain Tree)
Girth = 1.2 m (Measured from 0.5m from the ground) Tree Height (Approximate) = 16 to 18 m
(b) Flowering Tree
Scientific Name: Plumeria spp (Frangipani)
Girth = 0.85 m (As this is a low branching tree (with the lowest branching below 0.5m height from the ground) – the girth should be measured at the point just below the lowest branching) Tree Height (Approximate) = 10.5 to 11 m
(c) Cluster Palm Tree
Girth = 0.5 m (As this is a low branching tree (with the lowest branching below 0.5m height from the ground) – the girth should be measured at the point just below the lowest branching) Tree Height (Approximate) = 17 to 20 m
2. LTA Car Parking Matters (30%)
A proposed mixed use commercial building located at Upper Bedok Road has a gross floor area as follows:
a) 1st storey – Restaurant (Kitchen 50 sqm, Dining area 200 sqm)
b) 2nd storey – Shop 525 sqm, Snack Bar 70 sqm
c) 3rd storey – Offices 700 sqm
Calculate the requirements of the following provisions (show the computation):
(a) Ordinary car park lots
(b) Accessible (handicap friendly) car park lots
(c) Unloading Bay
2A Part plan of Singapore Master Plan 2014 showing
the location of ‘Upper Bedok Road’
As per the Code of Practice on Vehicle Parking Provision in Development
Proposals – 2011 Edition, 1.2 Zonal Standards;
Zonal car parking requirements are stipulated for commercial and entertainment
uses. For this purpose, Singapore Island is divided into three (3) zones.
Zone 1 comprises of the city (Restricted Zone) and the Marina Bay.
Zone 2 refers to the areas within 400m radius from rapid transit system
(RTS) stations outside Zone 1.
The rest of the island forms Zone 3.
The proposed mixed-use commercial building is located at Upper Bedok Road,
which falls in the Zone-2 Boundary of Tanah Merah MRT Station, i.e. within
400m radius of as shown in the pictures 2A and 2B.
2B HANDBOOK ON VEHICLE PARKING PROVISION IN DEVELOPMENT PROPOSALS, 2005 EDITION,
APPENDIX C, ZONE 2 PLANS AT MRT STATIONS
Page No. 123
COMPUTATION OF PARKING REQUIREMENT
ORDINARY CAR PARK LOTS AND ACCESSIBLE (HANDICAPPED-FRIENDLY) CAR PARK LOTS
S No Level Usage Gross Floor Area
(Sqm)
Parking Standard**
No. of Car Spaces Required (RCPS)
Computed Required
1 1st Storey Restaurant
(Kitchen + Dining)
250 sqm
Kitchen (50 sqm) +
Dining (200 sqm)
For 1st 150 sqm:
All Zones: 1 car space per 150 sqm
After 1st 150 sqm:
Zone 1 & 2: 1 car space per 60 sqm
2.67
(For 1st 150 sqm: 1
After 1st 150 sqm:
100/60 = 1.67
Total = 1+1.67 = 2.67)
2
2 2nd
Storey Shops 525 sqm
Zone 2:
1 car space per 200 sqm 2.625
(525/200 = 2.625) 3
3 Snack Bar
(Same as for
restaurant)
70 sqm For 1st 150 sqm:
All Zones: 1 car space per 150 sqm
After 1st 150 sqm:
Zone 1 & 2: 1 car space per 60 sqm
0.467
(70/150 = 0.467)
1
4 3rd
Storey Offices 700 sqm Zone 2: 1 car space per 250 sqm 2.8
(700/250 = 2.8) 3
TOTAL RCPS (Required Car Park Spaces) 8.562 9
TOTAL ALLOWABLE CAR PARK SPACES* 7
* Non-residential developments island wide in Zones 1 and 2 are allowed to provide up to 20% below the car parking requirement. This allowance is not
applicable to lorry, loading & unloading and coach parking requirements.
(20/100) x 9 = 1.8
9 – 1.8 = 7.2
Hence, this mixed-use commercial development at Upper Bedok Road is required to provide 9 car park spaces; but
allowed to provide 7 car park spaces. ACCESSIBLE (HANDICAPPED-FRIENDLY) CAR PARK LOTS***
For small developments, where the minimum requirements for car parking lots is 10 or less, NO additional accessible parking lot is required;
provided one of the lots is designed and constructed in accordance with the specification in the code, but without displaying the Symbol of Access. Should
the need arise; the car parking lot can be converted in to an accessible lot.
** Code of Practice on Vehicle Parking Provision in Development Proposals – 2011 Edition, Appendix A – Minimum Parking Provision Standards
*** Code on Accessibility in the Built Environment, 2013
COMPUTATION OF LOADING/ UNLOADING BAY REQUIREMENT
S No Level Usage Gross Floor Area
(Sqm)
Parking Standard**
No. of L/U Spaces Required
Computed Required
1 1st Storey Restaurant
(Kitchen + Dining)
250 sqm
Kitchen (50 sqm) +
Dining (200 sqm)
0 0 0
2 2nd
Storey Shops 525 sqm
All Zones: 1 loading/ unloading
space per 4,000 sqm 0.13
(525/4000 = 0.13) 0
3 Snack Bar 70 sqm 0 0 0
4 3rd
Storey Offices 700 sqm All Zones: 1 loading/unloading
space per 10,000 sqm (Up to 50,000
sqm)
0.07
(700/10000 = 0.07) 0
TOTAL REQUIRED L/U SPACES 0.2 0
TOTAL ALLOWABLE L/U SPACES* NA NA
* Non-residential developments island wide in Zones 1 and 2 are allowed to provide up to 20% below the car parking requirement. This allowance is not
applicable to lorry, loading & unloading and coach parking requirements.
This mixed-use commercial development at Upper Bedok Road requires NO loading/ unloading spaces.
** Code of Practice on Vehicle Parking Provision in Development Proposals – 2011 Edition, Appendix A – Minimum Parking Provision Standards
3. Fire Safety Matters (30%) (a) *The standard escape capacity of the whole floor =
100 persons per 0.5m width (Door Openings to Outdoors at Ground Level)
Hence, 200 persons for the given office for 1m exit door width
80 persons per 0.5m width (Door Openings to Other Exits and Corridor Doors)
Hence, 160 persons for the given office for 1m exit door width
60 persons per 0.5m width (Staircases)
Hence, 300 persons for the given office for 1.25m clear width of exit staircase for 2 staircases, i.e. (1.25/0.5) x 60 x 2 = 300
* Fire Code 2013, Chapter 2 Means of Escape, Table 2.2A Determination of Exit Requirement
COMPUTATION OF OCCUPANCY LOAD
FOR OFFICE BUILDING
Ref. Fire Code 2013 Chapter 1
S No Functional Spaces Area
(Sqm)
A
Occupancy
Load (sqm/
person)
OL
Occupancy
(Persons)
O = A/OL
1 General office area 900 10 90
2 Directors Offices 180 10 18
3 Office stores 60 10 6
4 Pantry 50 1.5 33 (33.3)
5 Lobby 50 3 17 (16.6)
6 Meeting rooms 90 1.5 60
7 Boardroom 60 1.5 40
8 Corridors 150 0 0
9 Staircases, lifts, toilets
200 0 0
TOTAL 1740 (All spaces
included)
1390
(Excluding
corridors,
staircases,
lifts,
toilets)
37.5 264