SENSOR EEG DAN ECG NON-KONTAK SERTA RENDAH NOISE
Oleh:
Ni Luh Desi Ratna ArisandiG1B012022
![Page 2: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/2.jpg)
POKOK PEMBAHASAN
1. Pendahuluan2. Desain Sensor
a. Desain rangkaianb. Tata letak
3. Karakterisasic. Gain dan fased. Kebisingan (noise)
4. Hasil dan Pembahasan5. Kesimpulan
![Page 3: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/3.jpg)
PENDAHULUAN
EEG/ECG sensor
![Page 4: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/4.jpg)
PENDAHULUAN
![Page 5: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/5.jpg)
Tujuan Penelitian
Mendesain sebuah sensor EEG/ECG yang mampu mengukur medan listrik pada otak dan jantung tanpa kontak langsung dengan kulit.
![Page 6: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/6.jpg)
DESAIN SENSOR
a. Desain rangkaian
![Page 7: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/7.jpg)
b. Tata letak
DESAIN SENSOR
Bagian atas sensorBagian bawah
sensor
![Page 8: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/8.jpg)
a. Gain dan faseGain dan fase diuji dengan lock-in amplifier. Semakin besar jarak sensor, kapasitansi kopling semakin rendah.
KARAKTERISASI
![Page 9: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/9.jpg)
b. KebisinganSinyal yang diukur bisa mencapai puluhan mikrovolt dari puncak ke puncak sehingga menghasilkan noise yang rendah
Pengaruh variasi jarak terhadap noise RTI
![Page 10: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/10.jpg)
HASIL DAN PEMBAHASAN
a. Sinyal pada otak yang diukur melalui rambut
b. Sinyal pada jantung melalui
pakaian
![Page 11: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/11.jpg)
![Page 12: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/12.jpg)
KESIMPULAN
Sensor EEG Dan ECG mampu mengukur medan listrik yang berasal dari otak melalui rambut dan jantung melalui pakaian dengan baik pada jarak 0.2-3.2 mm dari kulit, noise pada frekuensi 1-100 Hz mencapai 1.88 μVrms.
![Page 13: Sensor Eeg Dan Ecg Non-kontak Serta Rendah Noise](https://reader036.vdocuments.net/reader036/viewer/2022081722/5695d0451a28ab9b0291bfb6/html5/thumbnails/13.jpg)
TERIMA KASIH,,,,,,,,