© Invensys 00/00/00 Invensys proprietary & confidentialSlide 3
Market issues and needs
• Tailored units and solutions
• Short time to market
• Small unit size
• Energy saving solutions
• Maintenance cost reduction
• After market cost reduction
• Quicker validation and qualification tests
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 4
What’s “Free Way”
Eliwell’s new programmable platform combines speed and reliability in a complete range of compact and high performing products.
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 5
Benefits
• RAPIDITY: The programmable platform enables customers to be quicker in
delivering solutions for their customers. Specifically Free Way reduces the time
between defining a new application and placing it into production.
• COMPACT: The innovative technology encapsulated in the Free Body
controllers have facilitated the creation of high functionality in a modular, compact
size. The integrated solutions and smaller programmable controller size provides a
real and immediate economic advantages for customers.
• EFFICIENCY: The independence of the software application from the
hardware platform gives designers total freedom to develop new algorithms and
functions so that product performance can undergo continuous improvement.
Enhanced connectivity makes system integration easy, ensuring maximum
efficiency of end-user applications.
• RELIABILITY: The Free Body controllers and the Free Studio development
environment are made with innovative criteria that have been fully tried and tested
in other markets. The high standards of quality are certified and constantly
monitored providing customers the guarantee of reliability, which has always
distinguished the Eliwell brand.
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 6
“Free Way” system
The new Eliwell
programmable solution consists of a software suite Free Studio, a complete range of programmable controllers Free Body, user terminal and a set of accessories.
Key accessories are the Plug-in communication
modules which facilitate integration with Building Management systems in the residential, commercial and industrial end user applications.
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 8
Free StudioThe development environment for product programming,
compliant with IEC 61131-3 industrial standard, is structured on different
levels of use and lets the designer easily and intuitively manage every stage
of the software application: design, testing, debugging, mass production
and service in the field.
• Quick and easy programming
• Integrated software suite
• Complete and effective online Help
• Advanced debugging and simulation options
• Application protection
• Different levels of access
• Application revision log
• Customizable user interface
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 9
The platform offers tools dedicated to people with different needs, providing easy access for everyone:
© Invensys 2010 Invensys proprietary & confidential
Free Studio: easy to use
• Developer
• Manufacturer
• User
• Installer
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 10 © Invensys 2010 Invensys proprietary & confidential
Developers and
Manufactures:
• Writing code
• Menu creation
• Testing & debugging
• Download
• Export in the catalog
User and Installer
• Parameters setting
• Testing
• Create a solution with the catalog
• Download
(The code is not visible)
Free Studio: process
For Evolution:
• Application
• Device
• Interface
• Connection
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 11
• Multi-tasking Project
© Invensys 2010 Invensys proprietary & confidential
• Manage Libraries created by Eliwell and/or
Developer
• Variables, Structures, vectors, pointers:
Free Studio: Application
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 12
• Easy declarations of Parameters, Status and Alarms:
• Unit measure, scale, offset, visibility, etc.
© Invensys 2010 Invensys proprietary & confidential
• Rapid Menu Creation for Smart:
• Define folders
• Add Parameters
• Status to be displayed
• Define main view
• The same structure can be also transferred to
Device Studio
Free Studio: Application
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 13
• Debugging Tools
© Invensys 2010 Invensys proprietary & confidential
• Variables:
Free Studio: Application
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 14
Users and installers can use Device to:
• Download application
• R/W Parameters
• BIOS Update
© Invensys 2010 Invensys proprietary & confidential
• Test Application
• Create different configuration (.cfn)
• Developer and/or
Eliwell fill in application
catalogue
• Easy drag & drop can
create a “solution”
where hardware is
linked to application
Free Studio: Device
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 16
Free Smart
Free Smart lets customers achieve top performance in a compact size.
Available in the 32x74 and 4 DIN RAIL format
• Expandable with optional modules
• Panel and wall mounting remote user terminals
• RS-485 integrated on board
• Can be integrated in Modbus systems®
• 22 I/O in both formats
• 3 analogue outputs
• 5 analogue inputs
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 17 © Invensys 00/00/00 Invensys proprietary & confidential
• 5 analog input configurable independently:
� 3 Input configurable as Ntc, D.I (Ai1,Ai2,Ai5)
� 2 Input configurable as Ntc, D.I, 4…20mA, 0-10V, 0-5V or 0-1V (Ai3, Ai4)
• 6 digital input free of voltage.
• Up to 3 voltage/current analog output:
� AO3 and A04 are 0.10Vdc (max 28mA each, Min. 360 ohms load)
� AO5 configurable between 0.20mA or 4.20mA (max 350 ohms load)
• Up to 3 configurable analog output:
� AO1 and AO2 configurable between PPM (as driver for ext. Triac ) or PWM OpenCollector (12vdc 35mA)
� Up 2 triac @ 3A 250V output
� DO5 PWM open collector output @12vdc 35mA
• Up to 5 relay contacts @ 2 A 250Vac
• TTL or RS485 Modbus RTU, local lan
• RTC for /C models
• 12-24 Vac\dc power supply *
Free Smart: HW capabilities
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 18 © Invensys 2010 Invensys proprietary & confidential
MODEL INPUT OUTPUT
PowerSupply
NTCDI
NTCDI
4.20mA
0-10V
0-5V0-1V
DI RELAY@ 2 A 250VAC
OPENCOLL.
@12vdc 35mAfor:
PWMOr DO
OPENCOLL.@12vdc
35mAfor:
PWMDOPPMfor
external
Triac
0-10V0…204..20mA
Triac @ 3 A
250V for:
PWM-
PhaseCut
Triac @ 2 A
250V for:
PWM-
PhaseCut
SM*46
12VAC
24 VAC/VDC
(*)
AI1AI2AI5
AI3AI4
DI1DI2DI3DI4DI5DI6
DO1DO2DO3
DO4 DO5AO1AO2
AO3AO4
AO5
/TC1(**)
SM*55DO4DO6
DO5AO1AO2
/ /
SMD36SMC36
/DO4DO5
AO1TC1TC2
/
• * If TC1/TC2 AO1 AO2 are used for Phase Cut Control power supply must 12-24 VAC
•** The load must be bigger enough to switch the TRIAC (fan,…)
Free Smart: HW capabilities
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 19 © Invensys 2010 Invensys proprietary & confidential
• COM1 (UART1)
• Transistor-Transistor Logic (TTL) port connects to:
� Multi-function key
� DMI interface
� Bus Adapter
� Radio Adapter
• RS-485 (only /S model) connects to supervisor through ModBus-RTU protocol
• COM2 (UART2)
• Local Area Network (LAN) connects to:
� Expansion Board
� Local or Remote keyboard
� Electronic expansion valve
Free Smart: Communication
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 20 © Invensys 2010 Invensys proprietary & confidential
• SKP10 panel mounting LED keyboard
• SKW22 (L) wall mounting LCD keyboard
� L version available with backlight**
� 1 NTC built-in sensor
� 1 configurable input among NTC, 4.20mA or D.I.
• SKP22 (L) panel mounting LCD keyboard (coming soon)
� L version available with backlight**
� 1 NTC built-in sensor
� 1 configurable input among NTC, 4.20mA or D.I.
** Backlight version needs external power supply
Free Smart: User interface
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 21 © Invensys 2010 Invensys proprietary & confidential
It’s possible to double the capabilities of the hardware using 4-DIN expansion boards
MODEL INPUT OUTPUT
PowerSupply
NTCDI
NTCDI
4.20mA
0-10V0-5V0-1V
DI RELAY@ 2 A 250VAC
OPENCOLL.
@12vdc 35mA
for:PWMOr DO
OPENCOLL.
@12vdc 35mAfor:
PWMDO
PPMfor
external Triac
0-10V0…204..20
mA
Triac @ 3 A
250V
Triac @ 2 A
250V for:
PWM-PhaseCut
SE646
12-24VAC
AI1AI2AI5
AI3AI4
DI1DI2DI3DI4DI5DI6
DO1DO2DO3
DO4 DO5
AO1AO2
AO3AO4
AO5
/TC1(**)
SE655DO4DO6
DO5 / /
SE632 / / DO5 / / / /
•** The load must be bigger enough to switch the TRIAC (fan,…)
Free Smart: Expansions
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 22 © Invensys 2010 Invensys proprietary & confidential
Parameter Map � / �
Application � � �
Bios � � �
� Coming soon
• Multi-function key
• DMI Interface
(it can switch on Smart without external power supply)
• Demo case
Free Smart: How to connect
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 23 © Invensys 2010 Invensys proprietary & confidential
Local Area Network
Mod
bus-
RT
u ov
er R
S-4
85
Free SmartExpansion Board Electronic Expansion Valves
Local KeyboardOne Remote KeyboardSupervisor
Free Smart: Architecture
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 24 © Invensys 2010 Invensys proprietary & confidential
• TF411205 230/12VAC 6VA Transformer
• COLV000033200 Keyboard Harness
• MW320100 External Relay 16Amps
• COLV0000E0100 Low Voltage Harness
• COLV000035100 RS-485 Harness
• COLV000042100 Analog Output Harness
• TD400050 Ratiometric Pressure 0-50 bar Transducer
• D200130 Pressure transducer 0-30 bar (male fitting)
• Fan speed modules
Free Smart: Accessories
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 26
Free Evolution
Free Evolution is the top of the range of programmable controllers. It is
designed to meet the needs of more complex applications in the HVAC/R
market.
• Available in 8 DIN RAIL format
• Expandable up to 15 optional modules
• Built-in or remote graphic user terminals
• SMS function through Modem
• Can be integrated in industrial systems (CANopen® and Profibus®)
• Can be integrated in BMS systems (LonWorks®, BacNet® and Konnex®)
• Can be integrated in Ethernet networks (Modbus TCP/IP)
• Can be updated with standard USB pen drive
• PC connection via standard USB
• 27 inputs and outputs
• 5 analogue outputs
• 6 analogue inputs
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 27 © Invensys 00/00/00 Invensys proprietary & confidentialSlide 27
free Evolution Display Built-In
Case Size: - DIN 8Connectors - Fast, screw/spring , horizontal, p 5.0/3.8 Power Supply: - 24Vac/dc & 48Vdc (for Telecom apps.)Analog Inputs: - 6 (2 NTC + 4 configurable as NTC, DI, PT1000, 4-20mA, 0-10V, 0-5V ratiometric)
Digital Inputs : - 8+1 (8 voltage AC/DC, opto-isolated, +1 fast pulse-counter input)
Digital Outputs: - 7 Relays min. 5A/230Vac (2 SPDT with separate contacts + 3 SPST + 2 SPST/SSR)
Analog Outputs: - 5 (configurable 0-10V / 4-20mA).
Display & UI: - Graphic monochrome LCD 128x64 with backlight, 3 LEDs, 5 keys
Communication: - 1 port CANBUS/CANOpen (max 50m@500kbps, 200m@125kbps)
- 1 port RS485 optoisolated (Micronet, Modbus Master/Slave up to 38,4KB, BACnet)
(in alternative) 1 port MP-bus Master (for Belimo peripherals)
- 1 USB Host + 1 USB Device port, Mass Storage
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 28 © Invensys 00/00/00 Invensys proprietary & confidentialSlide 28
free Evolution Closed
Case,Power Supply, Connectors,Analog & Digital I/Os : - Same as D model
Display / UI: - 3 LEDs (external keyboard needed)
Connectivity: - Same as D model
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 29 © Invensys 00/00/00Slide 29
free Evolution Expansion
CANBUSRS485
Exp
Case,Power Supply, Connectors,Analog & Digital I/OsDisplay / UI : - Same as C model
Connectivity: - RS485, CANbus: acts as a DS401 CANopen profile
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 30 © Invensys 00/00/00 Invensys proprietary & confidentialSlide 30
free Evolution Serial Modules
Case: - DIN 2Connectors: - Fast, screw/spring
Serial ports: “PASSIVE”:- CANBUS (500kbps; max 50mt)
- RS485 optoisolated (Modbus Master/Slave;38,4KB)
- Ethernet (10/100)
- RS-232 (Industrial Modem) + Relay
- MP-BUS (optional)
“ ACTIVE”:- Profibus- Lonworks- Konnex- BACnet
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 31 © Invensys 00/00/00 Invensys proprietary & confidentialSlide 31
free Evolution Keyboard
Power Supply: - 24Vac/dc & 48Vdc (local or remote from Main controller)
Mounting: - Panel or Wall
Display: - Graphic monochrome LCD 128x64 with backlight)
Keys - 5 (same “navigation menu” as base EVO D controller)
Analog Inputs: - 1 NTC (built-in or remote)
- 1 RH% (buit-in or remote as 4-20 mA/DI )
Digital Outputs: - 1 Buzzer
Protection grade: - IP65 on the front panel
Serial ports: - 1 CANBUS opto-isolated
- 1 RS485 opto-isolated
- 1 Ethernet (in addition or altenative to CAN, for Network
model – Evolution KN)
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 32 © Invensys 00/00/00 Invensys proprietary & confidentialSlide 32
CPU midi I/O
Monitoring
FIELD: CANopen / RS485 / MP Bus
NETWORK: Ethernet (Plug-in) / CANopen
SUPERVISOR: RS-485 / Ethernet / Plug-ins
Main EXP
free Evolution connectivity ex. 1/2
It’s not allowed to overlap different communication levels (Field, Network, etc.) on the same physical layer, except for workbench, where applicable. EVO KN
EVO K
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 33 © Invensys 00/00/00 Invensys proprietary & confidentialSlide 33
I/O
I/O
CANbus
Ethernnet/CAN plug-in
RS-485
I/O Standard
Modbus Slave
I/O
Modbus Slave
Modbus Slave
free Evolution connectivity ex. 2/2
EVO KN
EVO K
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 34 © Invensys 00/00/00 Invensys proprietary & confidentialSlide 34
free EVOLUTION: Roadmap
Sep 2010
Engineering Samples
MiniDisplay
Ethernet
RS232
RS-485CAN
Profibus
LON
KNX
Expansion Mini
blind
KBD
Oct 2010 Dec 2010 Feb 2011
© Invensys 00/00/00 Invensys proprietary & confidentialSlide 36
Support Team
© Invensys 2010 Invensys proprietary & confidentialSlide 36
Customer Development
Customer Development
New Development
New Development
Integrated
Development
Integrated
Development
• To develop applications starting from the feasibility analysis phase, up to the code writing phase
• To develop dedicated libraries which will be used later on for creating a new application
• Hot-line support (mail/phone)
• Customer Training
• Web site
• Local German Support (soon)