� Spot Compaction MethodsDefaults Test Methods for:
� Non – Granular Subgrade
� Granular Subgrade
� Base
� Drainable Base
� Shouldering Material
� Acceptable Alternative Methods (Quality Compaction or LWD)
� Full Coverage Compaction Methods� Test Rolling
� Intelligent Compaction
![Page 3: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/3.jpg)
Defaults Spot Test Methods for:� Non – Granular Subgrade
Specified Density – Proctor
Optimum Moisture
Maximum Density (Target)
Compaction Compliance
Sand Cone
Nuclear Density Gauge
![Page 4: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/4.jpg)
Reasons for change� Vast majority of States, and private work allows for the device.
� Requested by local agencies.� Quick Results� ASTM and AASHTO Standards� Federal Approval� CO Safety Office procedures� Upped Testing Rate in Trenches for 2014
� Requirements for projects let in 2015 Certified by AASHTO Materials Reference Laboratory (AMRL)
![Page 5: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/5.jpg)
Defaults Spot Test Methods for Granular Subgrade & Base
Dynamic Cone Penetrometer (DCP)
![Page 6: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/6.jpg)
Defaults Test Methods for Surfacing Aggregate and Drainable Aggregate Base
Quality Compaction
![Page 7: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/7.jpg)
Quality Compaction or Light Weight Deflectometer may be substituted by Special provision for specified density or DCP
Still need Proctor for optimum moisture on non-granular material.
![Page 8: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/8.jpg)
![Page 9: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/9.jpg)
1) Review/Revise & place LWD procedure into the grading and base manual.
2) Place LWD as an option within the 2105/2106, and 2211 specifications, Schedule of Materials Control, & Independent Assurance requirements
3) Follow our current specification that requires the LWD yearly calibration per ASTM Standard E2835, and require proof (documentation) during IA review.
![Page 10: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/10.jpg)
![Page 11: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/11.jpg)
Quality Compaction Compact each lift until there is no further evidence of consolidation during compaction.
Add no evidence of (Ohio DOT):� Pumping – vertical displacement of the top surface of the
compacted layer, not directly under the vehicle tire. � Reaction – a movement back to a former or less advance condition. � Yielding – giving under pressure flexible.� Cracking – cracking of material on visible surface � Lateral movement – No lateral movement allowed
� Additionally all other compaction requirements must meet quality compaction
![Page 12: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/12.jpg)
![Page 13: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/13.jpg)
� Added Tandem – Now Test roller 30 and 10
� Standard for TR 10
� total weight for front axle,
� tires,
� deflection
� included quality compaction language
� Currently using feeler gauges on both, but researching using a laser/GPS for Test Roller 10.
![Page 14: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/14.jpg)
Developing/Evaluation/Researching
Contact Rebecca Embacher for information and Special Provisions
![Page 15: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/15.jpg)
� Four projects in 2014
� Transferring Responsibility to Contractor
� Gathering information/evaluating from this and next year’s projects
![Page 16: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/16.jpg)
� Moistures
� Aggregate Qualities
� Gradations
� Compaction
If interested contact me for special provisions.
![Page 17: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/17.jpg)
Revise G&B Manual (online and dated) each year.
Contact me to get on email update list.
![Page 18: Spot Compaction Methods - CEAM](https://reader036.vdocuments.net/reader036/viewer/2022081700/62d7d61eb83b5c464b515fe8/html5/thumbnails/18.jpg)
Le finis