7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 1/8
Testing and Adjusting 320D, 323D, 324D, 325D, 328D LCR and 330D Excavators Tool Control System
System 3: Default Value of Work Tool Parameters
SMCS - 5000
S/N - A3R1-UP
S/N - AZP1-UP
S/N - B6H1-UP
S/N - DHK1-UP
S/N - EDX1-UP
S/N - FXK1-UP
S/N - GTN1-UP
S/N - JJG1-UP
S/N - JLP1-UP
S/N - MEY1-UP
S/N - MWP1-UP
S/N - NBD1-UP
Note: For this system, parameters that are not shown in the tables do not affect the operation of thework tool.
The monitor displays the default screen when the start switch is turned to the ON position. Thedefault screen contains three gauges: fuel level, hydraulic oil temperature and engine coolanttemperature.
Use the following Illustration to operate the monitor.
Shutdown
Previous Screen
Product: EXCAVATOR
Model: 330D L EXCAVATOR B6H
Configuration: 330D L Excavator B6H00001-UP (MACHINE) POWERED BYC9 Engine
Media Number -RENR7389-04 Publication Date -01/04/2006 Date Updated -20/04/2006
i02436708
Página 1 de 8330D L Excavator B6H00001-UP (MACHINE) POWERED BY C9 Engine(SEBP4...
24/10/2007https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 2/8
Table 1 contains parameters for "TOOL#1" through "TOOL#5". Table 2 contains parameters for"TOOL#6" through "TOOL#10".
Illustration 1 g01197803
Monitor Panel
(1) Up key
(2) Right key
(3) Home key
(4) Main menu key
(5) Left key
(6) Down key
(7) Cancel key or back key
(8) OK key
Table 1
DISPLAY"TOOL #1" "TOOL #2" "TOOL
#3""TOOL #4" "TOOL #5"
"TOOL PROGRAM: GENERAL"
"NAME" H115 H120C H130 0 0
"MAX DIAL" 10 10 10 10 10
"MIN DIAL" 1 1 1 1 1
"UNDERSPEED ENABLED ENABLED ENABLED ENABLED ENABLED
Página 2 de 8330D L Excavator B6H00001-UP (MACHINE) POWERED BY C9 Engine(SEBP4...
24/10/2007https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 3/8
7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 4/8
7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 5/8
To access the tool parameters, enter the service mode on the monitor.
1. From the default screen, press the main menu key (4) .
2. From the "MAIN MENU" screen, use the right key (2) to scroll through the menu options.
3. When the "SERVICE" option is highlighted, press the OK key (8) .
4. When "PASSWORD" screen appears, use the right key (2) and the left key (5) in order toscroll through the characters. When the desired character is highlighted, press the OK key (8).Enter the password for service FFF2 in order to continue to the "SERVICE" screen.
5. After the password has been entered the "SERVICE" screen should appear. Refer toIllustration 2.
Note: For more detailed steps with entering passwords or entering the service mode, refer to
Troubleshooting Section, "Using Service Mode".
attachment valve
"A1 OPEN TIME"
Open time of thenumber 1
attachment valve
0.2 0.2 0.2 0.2 0.2
"A1 CLOSETIME" Close time of thenumber 1attachment valve
0.2 0.2 0.2 0.2 0.2
"TOOL PROGRAM -> ATTACHMENT #2 VALVE"
"A2 EXTND MAXPRES"
Maximum pressurefor the extension ofthe number 2attachment valve
4000 4000 4000 4000 4000
"A2 OPEN TIME"
Open time of thenumber 2attachment valve
0.2 0.2 0.2 0.2 0.2
"A2 CLOSETIME" Close time of thenumber 2attachment valve
0.2 0.2 0.2 0.2 0.2
Página 5 de 8330D L Excavator B6H00001-UP (MACHINE) POWERED BY C9 Engine(SEBP4...
24/10/2007https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 6/8
The table shows some of the approved Caterpillar work tools that are used. The table lists some ofthe parameters that should be verified for successful operation of the work tool.
Illustration 2 g01215792
Illustration 2 is a typical example of the "SERVICE" screen.
Table 3
SYSTEM 3
Work Tools Direction of Flow "SYSTEM 3 TOOL Number"
HammerH115
H120CH130
1 Way "TOOL 3"
Página 6 de 8330D L Excavator B6H00001-UP (MACHINE) POWERED BY C9 Engine(SEBP4...
24/10/2007https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 7/8
7/23/2019 System 3 Default Value of Work Tool Parameter
http://slidepdf.com/reader/full/system-3-default-value-of-work-tool-parameter 8/8