Download - Tankvision Field Link NXA30
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
System Component: Tank Gauging.
Protocol conversion.
Application: Communication
protocols conversion, remote
display.
Protocol conversion in real time,
gauge command support.
:: Seamless integration of different
vendor gauges into one
Tank Gauging System.
:: Upgrades of sites gradual.
SPK: NFI
71115426
Tankvision Field Link NXA30
NXA30-
Tankvision Field Link NXA30
Approval:
Non-hazardous area AA
Version:
Protocol conversion, loop FC
Special version, TSP-no. to be spec. YY
Housing:
DIN Rail D
Special version, TSP-no. to be spec. Y
Field Input:
xxx x Enraf GPU/BPM OE
xxx x Saab TRL2 OX
Special version, TSP-no. to be spec. 99
Field Output:
Modbus RTU RS485 T5
Special version, TSP-no. to be spec. 99
System Component: Tank Gauging.
Calculation, Monitoring.
Up to 400 tanks
Application: system architecture,
loops + protocols multiple,
customization.
Inventory calculations acc. API/ASTM.
Web server: Multi-user interface.
Archiving + reporting.
Connection > Tankvision Multi Scan.
:: High flexibility through a maximum
choice on interfaces .
:: Easiest adaption to user specific
requirements.
SPK: NFI
71114130
Tankvision Professional NXA85
NXA85-
Tankvision Professional NXA85
Version:
Stand alone A
Server S
Measuring:
<= 10 tanks 1
<= 30 tanks 2
<= 50 tanks 3
<= 100 tanks 4
> 100 tanks 5
Operation Language:
English AA
Special version, TSP-no. to be spec. 99
>>Application Package:
Product movements EA
Backup Scheduler EB
Page 1 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
SCADA run time license EC
SCADA design time licene ED
Redundancy support EE
Special version, TSP-no. to be spec. EY
>Application Package Client:
xxx x Client E1
>Input Multi Scan:
xxx x Multi Scan MC
>Input Modbus:
xxx x Modbus M4
>Input Whessoe WM550:
xxx x Whessoe WM550 M1
>Input Enraf CIU 858 GPU/RS232:
xxx x Enraf CIU 858 GPU/RS232 MN
>Input Enraf CIU Prime GPU/RS232:
xxx x Enraf CIU Prime GPU/RS232 MP
>Input Saab FCU2160:
xxx x Saab FCU 2160 MX
>Input OPC Client:
xxx x OPC Client NF
>Input Special Version:
Special version, TSP-no. to be spec. N9
>Output Modbus RTU:
xxx x Modbus RTU R4
>Output Modbus TCP:
xxx x Modbus TCP RJ
>Output Special Version:
Special version, TSP-no. to be spec. S9
>OPC Server (Ethernet) Output:
Data Access 1x connection VA
Data Access 2-5x connection concurrent VB
Data Access >5x connection concurrent VC
>Web Server Output:
2-5x connection concurrent WB
6-10x connection concurrent WC
11-15x connection concurrent WD
>15x connection concurrent WE
Transmits data to other host units like
PLC or DCS systems.
Connects via Ethernet up to
15 NXA820/NXA821.
SPK: NFI
71025617
Tankvision Host Link NXA822
NXA822-
Tankvision Host Link NXA822
Approval:
Non-hazardous area A
Communication; Output:
MODBUS serial; TCP/IP, Entis+ slave interface 1
Special version, TSP-no. to be spec. 9
Power Supply:
90-250VAC 50/60Hz 1
10.5-32VDC 2
Page 2 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Special version, TSP-no. to be spec. 9
Local Operation:
status display 1
Special version, TSP-no. to be spec. 9
Operation Language:
English A
Special version, TSP-no. to be spec. Y
Housing:
DIN rail mounting PBT, IP20 1
Special version, TSP-no. to be spec. 9
Redundancy:
w/o 1
Special version, TSP-no. to be spec. 9
Custody Transfer Approval:
not selected 0
Special version, TSP-no. to be spec. 9
Additional Option:
Basic version A
Special version, TSP-no. to be spec. Y
Connects up to 225 tanks or max 15
NXA820 and supports product sorting and
summarizing via a built-in HTML user
Interface, standby redundancy.
SPK: NFI
71025616
Tankvision Data Concentrator NXA821
NXA821-
Tankvision Data Concentrator NXA821
Approval:
Non-hazardous area A
Power Supply:
90-250VAC 50/60Hz 1
10.5-32VDC 2
Special version, TSP-no. to be spec. 9
Data Archive Memory Size:
1GB D
Special version, TSP-no. to be spec. Y
Local Operation:
status display 1
Special version, TSP-no. to be spec. 9
Operation Language:
English A
Special version, TSP-no. to be spec. Y
Housing:
DIN rail mounting PBT, IP20 1
Special version, TSP-no. to be spec. 9
Redundancy:
w/o 1
Special version, TSP-no. to be spec. 9
Custody Transfer Approval:
not selected 0
NMi type approval 1
PTB type approval 7
Special version, TSP-no. to be spec. 9
Page 3 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Additional Option:
Basic version A
Printer port, serial, W+M approved P
Special version, TSP-no. to be spec. Y
Connects to a single field loop with
tank gauging instruments.
It polls instruments on one field loop
and provides measured data on an
Ethernet port for other Tankvision
units.
Configuration and visualization via
built-in HTML based user interface.
Connects up to 15 tanks.
SPK: NFI
71025615
Tankvision Tank Scanner NXA820
NXA820-
Tankvision Tank Scanner NXA820
Approval:
Non-hazardous area A
Field Communication; Input:
Sakura V1 protocol; max 10 instruments 8
Whessoematic 550; max 15 instruments 1
MODBUS EIA485 master; max 15 instruments 4
Special version, TSP-no. to be spec. Y
Power Supply:
90-250VAC 50/60Hz 1
10.5-32VDC 2
Special version, TSP-no. to be spec. 9
Inventory Calculation:
Oil+gas 1
Special version, TSP-no. to be spec. 9
Data Archive Memory Size:
1GB D
Special version, TSP-no. to be spec. Y
Local Operation:
status display 1
Special version, TSP-no. to be spec. 9
Operation Language:
English A
Special version, TSP-no. to be spec. Y
Housing:
DIN rail mounting PBT, IP20 1
Special version, TSP-no. to be spec. 9
Redundancy:
w/o 1
Special version, TSP-no. to be spec. 9
Custody Transfer Approval:
not selected 0
NMI type approval 1
PTB type approval 7
Special version, TSP-no. to be spec. 9
Additional Option:
Basic version A
Special version, TSP-no. to be spec. Y
Page 4 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
System Component: Tank Gauging.
Data collection, Calculation,
Monitoring.
Up to 250 tanks.
Application: system architecture mixed,
Fieldbus loops + protocols multiple.
Inventory calculations acc. API/ASTM.
Web server: multi-user interface,
operating system independant.
:: Stand-alone/integrated
into larger system.
:: Upgrades of sites gradual.
SPK: NFI
71115427
Tankvision Multi Scan NXA83
NXA83-
Tankvision Multi Scan NXA83
Approval:
Non-hazardous area AA
Version:
Stand alone A
Redundancy support E
Special version, TSP-no. to be spec. Y
Housing:
Wall mounted H
19" Rack Montage - 8 channels R
19" Rack Montage - 16 channels T
Special version, TSP-no. to be spec. Y
Operation Language:
English AA
Special version, TSP-no. to be spec. 99
Field Protocol (input 1):
xxx x HART OH
xxx x Modbus RTU RS485 O5
xxx x Whessoe WM550 O1
xxx x Enraf GPU/BPM OE
xxx x Saab TRL2 OX
xxx x Scientific Instruments SI6290 PD
Special version, TSP-no. to be spec. 99
>Input HART:
xxx x HART OH
>Input Modbus RTU RS485:
xxx x Modbus RTU RS485 O5
>Input Whessoe WM550:
xxx x Whessoe WM550 O1
>Input Enraf GPU/BPM:
xxx x Enraf GPU/BPM OE
>Input Saab TRL2:
xxx x Saab TRL2 OX
>Input Scientific Instruments:
xxx x Scientific Instruments SI6290 PD
>Input Special Version:
Special version, TSP-no. to be spec. O9
>Output Multi Scan RS232:
xxx x Multi Scan RS232 TC
>Output Multi Scan RS485:
xxx x Multi Scan RS485 TD
>Output Multi Scan TCP:
xxx x Multi Scan Ethernet TCP TF
>Output Modbus RTU RS232:
xxx x Modbus RTU RS232 T4
Page 5 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
>Output Modbus RTU RS485:
xxx x Modbus RTU RS485 T5
>Output Modbus TCP:
xxx x Modbus TCP TJ
>Output Special Version:
Special version, TSP-no. to be spec. T9
>OPC Server (Ethernet) Output:
Data Access 1x connection VA
Data Access 2-5x connection concurrent VB
Data Access >5x connection concurrent VC
>>Hardware Option:
Touch screen XA
Special version, TSP-no. to be spec. X9
Level gauge based on servo principle.
For operation in process + storage
tanks, beverage, food stuff liquid
measurement.
SPK: NSA
52005626
Proservo NMS7 (Sanitary)
NMS7-
Proservo NMS7 (Sanitary)
Approval:
Weather proof, IP67 NEMA4X 0
TIIS Ex d IIB T4 1
Special version, TSP-no. to be spec. 9
Application:
Liquid level A
Liquid level, I/F level, density B
Special version, TSP-no. to be spec. Y
Output 1:
Not selected F
2-way 2-wire (V1 protocol) A
2-way 2-wire (BBB protocol) B
2-way 2-wire (MIC, RS232C protocol) C
2-way 2-wire (MIC protocol) D
2-way 2-wire (MDP protocol) J
4-20mA HART active G
4-20mA HART passive H
Whessmatic 550, overvoltage protection L
Mark Space M
Enraf BPM N
Modbus RS485 P
Special version, TSP-no. to be spec. Y
Output 2:
Not selected 0
4x relay SPST 1
2x 4-20mA 2
4x relay SPST, 2x 4-20mA 3
2x relay SPST, overfill prevention 4
Special version, TSP-no. to be spec. 9
Input:
HART (NMT5xx, NRF560, pressure transmitter) 0
1x spot temperature Pt100, HART (NMT5xx, NRF560, pressure transmitter) 1
2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 2
1x spot temperature Pt100, 2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 3
Page 6 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Special version, TSP-no. to be spec. 9
Measuring Range; Wire:
0-16m; SUS316, 0.2mm B
0-16m; PFA>SUS316, 0.4mm D
Special version, TSP-no. to be spec. Y
Cable Entry:
4x thread G1/2 A
4x thread G3/4 B
4x thread NPT1/2 C
4x thread NPT3/4 D
4x thread M20 G
4x thread M25 H
Special version, TSP-no. to be spec. Y
Process Connection:
10K 80A RF, SUS304 flange JIS B2220 A
10K 80A FF, SUS304 flange JIS B2220 B
3" 150lbs RF, SUS304 flange ANSI B16.5 C
DN80 PN10 B1, SUS304 flange EN1092-1 (DIN2527 B) D
80A 150lbs RF, SUS304 flange JPI 7S-15 E
Special version, TSP-no. to be spec. Y
Power Supply:
85-264VAC, 50/60Hz 0
20-62VDC, 20-55VAC, 50/60Hz 1
Special version, TSP-no. to be spec. 9
Displacer:
Cylindrical 50mm, SUS316 polished A
Cylindrical 40mm, SUS316 polished B
Cylindrical 30mm, SUS316 polished C
Cylindrical 50mm, PTFE D
Cylindrical 40mm, PTFE E
Cylindrical 30mm, PTFE F
Special version, TSP-no. to be spec. Y
O-ring; Drum Housing Inner Finish:
NBR; milled 0
Silicone rubber; polished 1
FKM; not selected 2
Silicone rubber; FEP coated 5
Special version, TSP-no. to be spec. 9
Nozzle:
Rc3/8, cleaning A
NPT3/8, cleaning B
G3/8, cleaning C
Rc3/8, gas purging D
NPT3/8, gas purging E
G3/8, gas purging F
Rc3/8, cleaning, gas purging G
NPT3/8, cleaning, gas purging H
G3/8, cleaning, gas purging J
Special version, TSP-no. to be spec. Y
Additional Option:
Not selected A
Custody transfer seal, wire lock B
Cleaned from oil+grease C
Sunshade D
Cleaned from oil+grease, custody transfer seal, wire lock E
Sunshade, custody transfer seal, wire lock F
Sunshade, cleaned from oil+grease G
Sunshade, cleaned from oil+grease, custody transfer seal, wire lock H
Special version, TSP-no. to be spec. Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Page 7 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
For operation in storage tanks with
liquids like oils, fuels, LPG etc. in
hazardous areas.
Interface-level and density measurement
optional. SPK: NSA
017402-9000
Proservo NMS5
NMS5-
Proservo NMS5
Drum Housing Pressure Rating; Material:
0… 200mbar/20kPa/2.9psi; Alu 1
0… 200mbar/20kPa/2.9psi; stainless steel 2
0… 5.88bar/588kPa/85.28psi; Alu 4
0… 5.88bar/588kPa/85.28psi; stainless steel 5
0… 24.5bar/2.45MPa/355.34psi; stainless steel 6
Special version, TSP-no. to be spec. 9
Approval:
Weather proof, IP67 NEMA4X 0
TIIS Ex d IIB T4 1
FM XP Cl. I Div.1 Gr.C-D 5
FM XP-AIS Cl.I Div.1 Gr.C-D N
CSA Cl. I Div.1 Gr.C-D 6
CSA Ex d(ia) Cl. I Div.1 Gr.C-D O
ATEX II 1/2G Ex d IIB T4, T3 G
ATEX II 1/2G Ex d IIC T4, T3 Q
ATEX II 1/2G Ex d IIB T4, T3, -40oC S
ATEX II 1/2G Ex d (ia) IIB T4, T3 J
ATEX II 1/2G Ex d (ia) IIB T4,T3, -40oC U
IEC Ex d ia IIB T4,T3 Ga/Gb A
IEC Ex d IIB T4,T3 Ga/Gb B
IEC Ex d IIC T4,T3 Ga/Gb C
IEC Ex d ia IIB T4,T3 Ga/Gb, -40oC D
IEC Ex d IIB T4,T3 Ga/Gb, -40oC E
Special version, TSP-no. to be spec. 9
Application:
Liquid level A
PTB (<1mm) type approval, liquid level B
NMi (<1mm) type approval, liquid level C
Multi measurement, Liquid level, I/F level, bottom, density D
PTB (<1mm) type approval, liquid level, I/F level, bottom, density E
NMi (<1mm) type approval, liquid level, I/F level, bottom, density F
Density profile multi measurement, Liquid level, I/F level, bottom, density G
PTB (<1mm) type approval, density profile, liquid level, I/F level, bottom, density H
NMi (<1mm) type approval, density profile, liquid level, I/F level, bottom, density J
Special version, TSP-no. to be spec. Y
Output 1:
Not selected F
2-way 2-wire (V1 protocol) A
2-way 2-wire (MDP protocol) J
2-way 2-wire (BBB protocol) B
2-way 2-wire (MIC, RS232C protocol) C
2-way 2-wire (MIC protocol) D
4-20mA HART active G
4-20mA HART passive H
Whessmatic 550, overvoltage protection L
Mark Space M
Enraf BPM N
Modbus RS485 P
Special version, TSP-no. to be spec. Y
Page 8 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Output 2:
Not selected 0
4x relay SPST 1
2x 4-20mA 2
4x relay SPST, 2x 4-20mA 3
2x relay SPST, overfill prevention TÜV 4
4x relay SPST, 1x 4-20mA 5
Special version, TSP-no. to be spec. 9
Input:
HART (NMT5xx, NRF560, pressure transmitter) 0
1x spot temperature Pt100, HART (NMT5xx, NRF560, pressure transmitter) 1
2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 2
1x spot temperature Pt100, 2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 3
1x status, HART (NMT5xx, NRF560, pressure transmitter) 4
1x spot temperature Pt100, 1x status, HART (NMT5xx, NRF560, pressure transmitter) 5
1x spot temperature Pt100, 1x status, 2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 6
Special version, TSP-no. to be spec. 9
Measuring Range; Wire:
0-28m; SUS316, 0.15mm C
0-36m; SUS316, 0.15mm L
0-16m; PFA>SUS316, 0.4mm H
0-16m; AlloyC, 0.2mm K
0-22m; AlloyC, 0.2mm M
*0-47m; SUS316, 0.15mm N
Special version, TSP-no. to be spec. Y
Cable Entry:
4x thread G1/2 E
4x thread G3/4 F
4x thread NPT1/2 G
4x thread NPT3/4 H
4x thread M20 L
4x thread M25 M
Special version, TSP-no. to be spec. Y
Process Connection:
10K 80A RF, flange JIS B2220 A
10K 80A FF, flange JIS B2220 C
10K 150A RF, flange JIS B2220 U
20K 80A RF, flange JIS B2220 E
3" 150lbs RF, flange ANSI B16.5 G
3" 300lbs RF (apply for NMS5-6), flange ANSI B16.5 J
6" 150lbs RF, flange ANSI B16.5 T
DN80 PN10 B1, flange EN1092-1 (DIN2527 B) L
DN80 PN25 B1, flange EN1092-1 (DIN2527 B) N
80A 150lbs RF, flange JPI 7S-15 Q
80A 300lbs RF (apply for NMS5-6), flange JPI 7S-15 S
Special version, TSP-no. to be spec. Y
Power Supply:
85-264VAC, 50/60Hz 3
20-62VDC, 20-55VAC, 50/60Hz 4
Special version, TSP-no. to be spec. 9
Displacer:
Cylindrical 30mm, SUS316 N
Cylindrical 40mm, SUS316 K
Cylindrical 50mm, SUS316 D
Cylindrical 50mm, AlloyC T
Conical 70mm, SUS316 R
Conical 110mm, SUS316 S
Special version, TSP-no. to be spec. Y
O-ring; Drum Housing Inner Finish:
NBR; not selected 0
Page 9 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Silicone rubber; not selected 1
Silicone rubber; FEP coated 5
PTFE (wire drum FKM); not selected 3
PTFE (wire drum FKM); FEP coated 4
CR; not selected 6
FKM; not selected 2
Special version, TSP-no. to be spec. 9
Additional Option:
Not selected A
Rc3/8 cleaning nozzle C
Rc3/8 gas purging nozzle D
Guide wire installation E
Relief valve G
Relief valve, pressure gauge H
Sunshade J
Rc3/8 gas purging nozzle, sunshade L
Special version, TSP-no. to be spec. Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Magnet float type tank gauge by flange
mounting with numeric display.
SPK: NSB
52007808
Float Gauge LT1222
LT1222-
Float Gauge LT1222
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
10K 40A RF, flange JIS B2220 1
1-1/2" 150lbs RF, flange ANSI B16.5 2
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
Special version, TSP-no. to be spec. 9
Display:
Numeric (mechanical counter) 2
Application:
Gauge head only 000
Seal pipe not selected 212
Seal pipe SUS316 214
Seal pipe PVC, wetted/gas parts 215
Special version, TSP-no. to be spec. 999
Seal Pipe:
Not selected 0
xxx mm 10K 40A RF, SUS316 flange JIS B2220 1
xxx mm 20K 40A RF, SUS316 flange JIS B2220 2
xxx mm 10K 50A FF, PVC flange JIS B2220 3
xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4
xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5
xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6
Special version, TSP-no. to be spec. 9
Float:
Page 10 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Not selected 0
Low pressure, SUS316 1
High pressure, SUS316 2
Special version, TSP-no. to be spec. 9
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Magnet float type tank gauge by screw
mounting with numeric display.
SPK: NSB
52007806
Float Gauge LT1122
LT1122-
Float Gauge LT1122
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
Thread JIS B0203 Rp1-1/2 0
Thread JIS B0203 Rc1-1/2, union nut 6
Thread ANSI NPT1-1/2, union nut 7
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
Special version, TSP-no. to be spec. 9
Display:
Numeric (mechanical counter) 2
Application:
Gauge head only 000
Seal pipe not selected 202
Seal pipe SUS316 204
Seal pipe PVC, wetted/gas parts 205
Special version, TSP-no. to be spec. 999
Seal Pipe:
Not selected 0
xxx mm 10K 40A RF, SUS316 flange JIS B2220 1
xxx mm 20K 40A RF, SUS316 flange JIS B2220 2
xxx mm 10K 50A FF, PVC flange JIS B2220 3
xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4
xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5
xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6
Special version, TSP-no. to be spec. 9
Float:
Not selected 0
Low pressure, SUS316 1
High pressure, SUS316 2
Special version, TSP-no. to be spec. 9
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Page 11 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Tagging (TAG), see additional spec. 1
Float type tank gauge with flange
mounting type under high pressure
application (2.5MPa/25bar).
SPK: NSB
52007804
Float Gauge LT16 (LT1600)
LT16-
Float Gauge LT16 (LT1600)
Display:
Dial 2 pointers 1
Numeric (mechanical counter) 2
Dial 2 pointers, up side down 5
Special version, to be specified 9
Crank Unit:
Not selected 0
Selected 1
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
10K 40A RF, SCPL1, SNB7 flange JIS B2220 1
20K 40A RF, SCPL1, SNB7 flange JIS B2220 2
10K 40A RF, SCS13, SUS304 flange JIS B2220 A
20K 40A RF, SCS13, SUS304 flange JIS B2220 B
20K 40A RF, SCS13, SNB7 flange JIS B2220 G
1-1/2" 150lbs RF, SCPL1, SNB7 flange ANSI B16.5 3
1-1/2" 300lbs RF, SCPL1, SNB7 flange ANSI B16.5 4
1-1/2" 150lbs RF, SCS13, SUS304 flange ANSI B16.5 C
1-1/2" 300lbs RF, SCS13, SUS304 flange ANSI B16.5 D
1-1/2" 300lbs RF, SCS13, SNB7 flange ANSI B16.5 H
40A 150lbs RF, SCLP1, SNB7 flange JPI 7S-15 5
40A 300lbs RF, SCLP1, SNB7 flange JPI 7S-15 6
40A 150lbs RF, SCS13, SUS304 flange JPI 7S-15 E
40A 300lbs RF, SCS13, SUS304 flange JPI 7S-15 F
40A 300lbs RF, SCS13, SNB7 flange JPI 7S-15 J
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
16m 4
20m 5
30m 6
Special version, TSP-no. to be spec. 9
Application:
Gauge head only, accessories ordered by selection tool AAA
Gauge head only 000
Standard, sheave elbow 90o x1, 135o x2 042
Sheave elbow 90o x2 043
Tank top installation 044
Standard, sheave elbow 90o x1, 135o x2, crank unit 096
Sheave elbow 90o x2, crank unit 097
Special version, TSP-no. to be spec. 999
Float:
Not selected 4
8.3kg, d=400mm 5
Page 12 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Special version, TSP-no. to be spec. 9
Additional Option:
Basic version 0
Gauge head bolts SUS304 B
Copper free C
Copper free, gauge head bolts SUS304 F
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Float type tank gauge with flange
mounting type under middle pressure
application (0.1MPa/1.0bar).
SPK: NSB
52007803
Float Gauge LT14 (LT1400)
LT14-
Float Gauge LT14 (LT1400)
Display:
Dial 2 pointers 1
Numeric (mechanical counter) 2
Dial 2 pointers, up side down 5
Special version, TSP-no. to be spec. 9
Crank Unit:
Not selected 0
Selected 1
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
10K 40A RF, AC4CT6 flange JIS B2220 1
10K 40A RF, SCS13 flange JIS B2220 A
1-1/2" 150lbs RF, AC4CT6 flange ANSI B16.5 3
1-1/2" 150lbs RF, SCS13 flange ANSI B16.5 C
40A 150lbs RF, AC4CT6 flange JPI 7S-15 5
40A 150lbs RF, SCS13 flange JPI 7S-15 E
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
16m 4
20m 5
30m 6
Special version, TSP-no. to be spec. 9
Application:
Gauge head only, accessories ordered by selection tool AAA
Gauge head only 000
Standard, sheave elbow 90o x2 040
Wetted/gas parts SUS316, sheave elbow 90o x1, 135o x2 041
Alu, sheave elbow 90o x1, 135o x2 078
Standard, sheave elbow 90o x2, crank unit 094
Wetted/gas parts SUS316, crank unit, sheave elbow 90o x1, 135o x2 095
Alu, sheave elbow 90o x1, 135o x2, crank unit 098
Special version, TSP-no. to be spec. 999
Float:
Not selected 4
Page 13 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
8.0kg, d=400mm 5
Special version, TSP-no. to be spec. 9
Additional Option:
Basic version 0
Copper free C
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Float type tank gauge according to wire
float type under low pressure
application (20kPa/0.2bar).
Display position: upper.
SPK: NSB
52007809
Float Gauge LTC2230
LTC2230-
Float Gauge LTC2230
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
10K 150A RF, SS400 flange JIS B2220 0
6" 150lbs RF, SS400 flange ANSI B16.5 1
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
Special version, TSP-no. to be spec. 9
Display:
Dial 1 pointer 1
Special version, TSP-no. to be spec. 9
Application:
Gauge head only 000
Standard application 081
Special version, TSP-no. to be spec. 999
Float:
2.1kg, d=140mm (0.5-0.93g/cm3) 1
2.4kg, d=140mm (0.94-2.0g/cm3) 2
Not selected 3
Special version, TSP-no. to be spec. 9
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Page 14 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Float type tank gauge with screw
mounting type under low pressure
application (20kPa/0.2bar).
SPK: NSB
52007801
Float Gauge LT11 (LT1100)
LT11-
Float Gauge LT11 (LT1100)
Display:
Dial 2 pointers 1
Numeric (mechanical counter) 2
Dial 2 pointers, up side down 5
Special version, TSP-no. to be spec. 9
Crank Unit:
Not selected 0
Selected 1
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
Thread JIS B0203 Rp 1-1/2, w/o union nut, SUS316 0
Thread JIS B0203 Rc 1-1/2, union nut, sleeve, SUS316 A
Thread ANSI NPT1-1/2, union nut, sleeve, SUS316 B
Thread JIS B0202 G1-1/2, union nut, sleeve, SUS316 C
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
16m 4
20m 5
30m 6
Special version, TSP-no. to be spec. 9
Application:
Gauge head only, accessories ordered by selection tool AAA
Gauge head only 000
CRT, guide pipe installation 005
Tank top, guide pipe installation 008
PVC, SS400 wire hook 060
PVC, SUS316 wire hook 062
Gas holder 251
FRT tank 261
Standard application for CRT, tape not installed, (solid guide wire, 2 anchor hooks) A01
Wetted parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A04
Wetted/gas parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A06
Underground standard, tape not installed, (solid guide wire, 2 anchor hooks) A07
Underground standard, SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A10
Seal pot standard, tape not installed, (solid guide wire, 2 anchor hooks) A50
Seal pot all SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A54
Standard, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B01
Wetted parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B04
Wetted/gas parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B06
Seal pot standard, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B50
Seal pot SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B54
Underground tank installation, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) C07
Underground tank installation, tape not installed, (solid guide wire, 2 anchor hooks) C10
Special version, TSP-no. to be spec. 999
Page 15 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Float:
Not selected 4
4.2kg, d=400mm 1
5.0kg, d=400mm 2
8.0kg, d=400mm 3
2.1kg, d=140mm 5
2.4kg, d=140mm 6
Special version, TSP-no. to be spec. 9
Additional Option:
Basic version 0
Copper free C
Glass display cover D
Copper free, glass display cover J
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Magnet float type tank gauge by flange
mounting with dial display.
SPK: NSB
52007807
Float Gauge LT1212
LT1212-
Float Gauge LT1212
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
10K 40A RF, flange JIS B2220 1
1-1/2" 150lbs RF, flange ANSI B16.5 2
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
Special version, TSP-no. to be spec. 9
Display:
Dial 2 pointers 1
Special version, TSP-no. to be spec. 9
Application:
Gauge head only 000
Seal pipe not selected 212
Seal pipe SUS316 214
Seal pipe PVC, wetted/gas parts 215
Special version, TSP-no. to be spec. 999
Seal Pipe:
Not selected 0
xxx mm 10K 40A RF, SUS316 flange JIS B2220 1
xxx mm 20K 40A RF, SUS316 flange JIS B2220 2
xxx mm 10K 50A FF, PVC flange JIS B2220 3
xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4
xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5
xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6
Special version, TSP-no. to be spec. 9
Float:
Not selected 0
Low pressure, SUS316 1
Page 16 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
High pressure, SUS316 2
Special version, TSP-no. to be spec. 9
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Float type tank gauge with flange
mounting type under low pressure
application (20kPa/0.2bar).
SPK: NSB
52007802
Float Gauge LT12 (LT1200)
LT12-
Float Gauge LT12 (LT1200)
Display:
Dial 2 pointers 1
Numeric (mechanical counter) 2
Dial 2 pointers, up side down 5
Special version, TSP-no. to be spec. 9
Crank Unit:
Not selected 0
Selected 1
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
10K 40A RF, AC4A flange JIS B2220 1
10K 40A RF, SUS316 flange JIS B2220 A
1-1/2" 150lbs RF, AC4C flange ANSI B16.5 2
1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 B
40A 150lbs RF, AC4A flange JPI 7S-15 3
40A 150lbs RF, SUS316 flange JPI 7S-15 C
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
16m 4
20m 5
30m 6
Special version, TSP-no. to be spec. 9
Application:
Gauge head only, accessories ordered by selection tool AAA
Gauge head only 000
PVC, SS400 wire hook 061
PVC, SUS316 wire hook 063
Gas holder 252
FRT tank 262
Standard application for CRT, tape not installed, (solid guide wire, 2 anchor hooks) A11
Wetted parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A14
Wetted/gas parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A15
Underground standard, tape not installed, (solid guide wire, 2 anchor hooks) A40
Underground standard, SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A43
Standard, seal pot, tape not installed, (solid guide wire, 2 anchor hooks) A55
Seal pot all SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A59
Page 17 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Standard, seal pot, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B55
Seal pot all SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B59
Standard, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B11
Wetted parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B14
Wetted/gas parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B15
Underground tank installation, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B40
UTI, wetted parts SUS316, crank unit, tape not installed, UTI = Underground tank installation (solid guide wire, 2 anchor hooks) B43
Special version, TSP-no. to be spec. 999
Float:
Not selected 4
4.2kg, d=400mm 1
5.0kg, d=400mm 2
8.0kg, d=400mm 3
Special version, TSP-no. to be spec. 9
Additional Option:
Basic version 0
Copper free C
Glass display cover D
Copper free, glass display cover J
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Magnet float type tank gauge by screw
mounting with dial display.
SPK: NSB
52007805
Float Gauge LT1112
LT1112-
Float Gauge LT1112
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
Thread JIS B0203 Rp1-1/2 0
Thread JIS B0203 Rc1-1/2, union nut 6
Thread ANSI NPT1-1/2, union nut 7
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
Special version, TSP-no. to be spec. 9
Display:
Dial 2 pointers 1
Special version, TSP-no. to be spec. 9
Application:
Gauge head only 000
Seal pipe not selected 202
Seal pipe SUS316 204
Seal pipe PVC, wetted/gas parts 205
Special version, TSP-no. to be spec. 999
Seal Pipe:
Not selected 0
Page 18 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
xxx mm 10K 40A RF, SUS316 flange JIS B2220 1
xxx mm 20K 40A RF, SUS316 flange JIS B2220 2
xxx mm 10K 50A FF, PVC flange JIS B2220 3
xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4
xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5
xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6
Special version, TSP-no. to be spec. 9
Float:
Not selected 0
Low pressure, SUS316 1
High pressure, SUS316 2
Special version, TSP-no. to be spec. 9
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Float type tank gauge according to wire
float type under low pressure
application (20kPa/0.2bar).
Display position: down.
SPK: NSB
52007810
Float Gauge LTC2240
LTC2240-
Float Gauge LTC2240
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection:
10K 150A RF, SS400 flange JIS B2220 0
6" 150lbs RF, SS400 flange ANSI B16.5 1
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
Special version, TSP-no. to be spec. 9
Display:
Dial 1 pointer 1
Special version, TSP-no. to be spec. 9
Application:
Gauge head only 000
Standard application 083
Special version, TSP-no. to be spec. 999
Float:
2.1kg, d=140mm (0.5-0.93g/cm3) 1
2.4kg, d=140mm (0.94-2.0g/cm3) 2
Not selected 3
Special version, TSP-no. to be spec. 9
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Page 19 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Level switch according to displacer
principle.
SPK: NSD
52007827
Level Switch MPC2000
MPC2-
Level Switch MPC2000
Type:
Not selected 0
Internal pipe 1
External pipe (side-side installation 25A/1") 2
External pipe (side-bottom installation 25A/ 1") 3
Heat Radiation:
w/o fin, max 100oC 0
Double fin, max 250oC 1
Single fin, max 150oC 2
Switch Count:
1x Level 1
2x Level 2
3x Level 3
4x Level 4
1x FRT Overflow detection 5
1x CRT Overflow detection 6
Approval:
Special version, TSP-no. to be spec. 9
Flame proof d2G4, TIIS + cable gland B
Flame proof d2G4, TIIS E
Weather proof IP65 W
Weather proof IP65 + cable connector X
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Process Connection, Top Mounted Flange:
10K 65A RF, SUS304 flange JIS B2220 3
10K 65A RF, SUS316 flange JIS B2220 4
10K 80A RF, SUS304 flange JIS B2220 1
10K 80A RF, SUS316 flange JIS B2220 2
10K 100A RF, SUS304 flange JIS B2220 S
10K 100A RF, SUS316 flange JIS B2220 T
20K 65A RF, SUS304 flange JIS B2220 7
20K 65A RF, SUS316 flange JIS B2220 8
20K 80A RF, SUS304 flange JIS B2220 5
20K 80A RF, SUS316 flange JIS B2220 6
2-1/2" 150lbs RF, SUS304 flange ANSI B16.5 C
2-1/2" 150lbs RF, SUS316 flange ANSI B16.5 D
2-1/2" 300lbs RF, SUS304 flange ANSI B16.5 G
2-1/2" 300lbs RF, SUS316 flange ANSI B16.5 H
3" 150lbs RF, SUS304 flange ANSI B16.5 A
3" 150lbs RF, SUS316 flange ANSI B16.5 B
3" 300lbs RF, SUS304 flange ANSI B16.5 E
3" 300lbs RF, SUS316 flange ANSI B16.5 F
4" 150lbs RF, SUS304 flange ANSI B16.5 U
4" 150lbs RF, SUS316 flange ANSI B16.5 V
65A 150lbs RF, SUS304 flange JPI 7S-15 L
65A 150lbs RF, SUS316 flange JPI 7S-15 M
65A 300lbs RF, SUS304 flange JPI 7S-15 Q
Page 20 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
65A 300lbs RF, SUS316 flange JPI 7S-15 R
80A 150lbs RF, SUS304 flange JPI 7S-15 J
80A 150lbs RF, SUS316 flange JPI 7S-15 K
80A 300lbs RF, SUS304 flange JPI 7S-15 N
80A 300lbs RF, SUS316 flange JPI 7S-15 P
100A 150lbs RF, SUS304 flange JPI 7S-15 W
100A 150lbs RF, SUS316 flange JPI 7S-15 X
Special version, TSP-no. to be spec. 9
Switch Position:
Lower 0
Lower + upper 1
Upper 2
Pipe:
Not selected 0
xxx mm T, internal pipe, SGP/SS 1
xxx mm T, internal pipe, SUS304 2
xxx mm T, internal pipe, SUS316 3
xxx mm S, external pipe, STPG/SS, S25C 4
xxx mm S, external pipe, SUS304 5
xxx mm S, external pipe, SUS316 6
Special version, TSP-no. to be spec. 9
Set Point:
mm H, flange-SW1 (300-3850mm) A
mm H mm L1 H=flange-SW1 L1=SW1-SW2 B
mm H mm L1 mm L2, H=flange-SW1 L1=SW1-SW2 L2=SW2-SW3 C
mm H mm L1 mm L2 mm L3, H=flange-SW1 L1=SW1-SW2 L2=SW2-SW3, L3=SW3-SW4 D
Special version, TSP-no. to be spec. Y
Cable Entry:
Thread PF(G)3/4 0
Thread PF(G)3/4, TF16-11 1
Thread PF(G)1, TF22-13 2
Thread PF(G)1, TF22-15 3
Thread PF(G)1-1/4, TF28-18 4
Thread NPT3/4 5
Special version, TSP-no. to be spec. 9
Density Range:
Not selected 0
0.65 - 1.2g/cm3, see additional spec. 3
Special version, TSP-no. to be spec. 9
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Integrating a radar/servo +
5 other HART sensors into a
Tank Inventory System.
Setup-/diagnostic software
included.
Inputs for spot RTD, analogue 4-20mA
in- and outputs, 2 discrete contact
in-/outputs (solid state).
:: Graphic LC display with backlight.
:: Various industry protocols available.
:: Easy commissioning.
:: Provides intrinsic safe supply
for connected sensors.
SPK: NSE
52011355
Tank Side Monitor NRF590
NRF590-
Tank Side Monitor NRF590
Page 21 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Approval:
Non-hazardous area A
ATEX II 2 (1) EEx d (ia) IIC T6 6
CSA XP Cl.I Div.1 Gr.A-D, zone 1,2 U
FM XP Cl.I Div.1 Gr.A-D, zone 1,2 S
TIIS EEx d (ia) IIC T4 K
Special version, TSP-no. to be spec. Y
Field Communication Protocol Ex d/XP:
ENRAF BPM, 4-20mA input, 4-20mA HART output E
GPE, 4-20mA output, 4-20mA HART output G
Whessoe WM550 (dualer output), 4-20mA output, 4-20mA HART output 1
VAREC Mark/Space, 4-20mA input, 4-20mA HART output 3
Modbus EIA 485 4
Modbus EIA 485, 4-20mA Input, 4-20mA HART output 5
L&J, 4-20mA input, 4-20mA HART output 7
Sakura V1, 4-20mA output, 4-20mA HART output, Relay output 8
Special version, TSP-no. to be spec. 9
Power Supply:
18-55V AC/DC A
55-264VAC B
Special version, TSP-no. to be spec. Y
Spot Rtd Option:
Not selected 0
Intrinsically safe input 1
Special version, TSP-no. to be spec. 9
Digital Module A:
Not selected A
Input 90-140VAC B
Input 3-32VDC C
Input 180-264VAC D
Input 35-60VAC/DC E
Output 24-250VAC G
Output 3-60VDC H
Output 24-140VAC J
Output 4-200VDC K
Relay 0-100VDC, 0-120VAC R
Special version, TSP-no. to be spec. Y
Digital Module B:
Not selected A
Input 90-140VAC B
Input 3-32VDC C
Input 180-264VAC D
Input 35-60VAC/DC E
Output 24-250VAC G
Output 3-60VDC H
Output 24-140VAC J
Output 4-200VDC K
Relay 0-100VDC, 0-120VAC R
Special version, TSP-no. to be spec. Y
Additional Intrinsically Safe Module:
Input 4-20mA + 2x input digital 2
Special version, TSP-no. to be spec. 9
Cable Entry (Non-IS):
2x Ex d gland G1/2 F
2x Ex d thread M20 (Non Ex > gland M20) B
2x Ex d thread G1/2 C
2x Ex d thread NPT1/2 D
2x Ex d thread NPT3/4 E
3x Ex d thread M20 (Non Ex > gland M20) H
3x Ex d thread G1/2 K
3x Ex d thread NPT1/2 L
Special version, TSP-no. to be spec. Y
Page 22 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Entry - IS Compartment:
2x Gland M25, 13-18mm 2
2x Thread G1/2 3
2x Thread NPT1/2 4
2x Thread NPT3/4 5
Special version, TSP-no. to be spec. 9
Weight + Measure Approval:
Not selected N
NMi type approval A
PTB type approval G
Special version, TSP-no. to be spec. Y
Additional Option:
Basic version 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
for oil leakage detecting system.
SPK: NSH
52006073
Transmitter NRR262
NRR262-
Transmitter NRR262
Approval:
Ex ia IIB T4, TIIS (NAR300), see additional spec. 2
Special version, TSP-no. to be spec. 9
Power Supply:
90-250VAC 50/60Hz A
22-26VDC B
Special version, to be specified Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Advanced technology oil leak
detection for use in depot, refinery,
power plants etc. for environment
protection.
SPK: NSH
56004244
Oil leak detector NAR300
NAR300-
Oil leak detector NAR300
Approval:
Ex ia IIB T4, TIIS 1
Special version, TSP-no. to be spec. 9
Type:
Float 1
Float, module set (Econounce NRR261 upgrade) 2
Float, Ex box (Econounce NRR262 upgrade) 4
Float, Ex box (separate type) 5
Special version, TSP-no. to be spec. 9
Page 23 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Output:
2-wire current A
Special version, TSP-no. to be spec. Y
Signal Cable:
6m A
10m B
15m C
20m D
25m E
30m F
Special version, TSP-no. to be spec. Y
Float Guide:
Not used 1
**Guide 304, weight SS400 2
**Guide 304, weight 304 3
Special version, TSP-no. to be spec. 9
Cable Entry:
Not needed A
G1/2 B
NPT1/2 C
M25 E
Special version, TSP-no. to be spec. Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
for oil leakage detecting system.
SPK: NSH
52006072
Transmitter NRR261, Ex d
NRR261-
Transmitter NRR261, Ex d
Approval:
Ex d ia, IIB T4 TIIS (NAR300) 2
TIIS Ex d(ia) IIB T4 (NAR300 separate type) 3
Special version, TSP-no. to be spec. 9
Power Supply:
90-250VAC 50/60Hz A
22-26VDC B
Special version, TSP-no. to be spec. Y
Cable Entry:
G3/4 x2 (Ex d) A
NPT3/4 x2 (Ex d) B
M25 x2 (Ex d) D
G3/4 x2 (Ex d), G1/2 x1 (Ex ia) E
G1/2 x2 (Ex d), G1/2 x1 (Ex ia) K
Special version, TSP-no. to be spec. Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Page 24 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Level and temperature indicator
directly connected to the HART input
of Proservo NMS.
Tank side mounted in hazardous area.
Operated via optical keys. SPK: NSI
017405-9000
Promonitor NRF560
NRF560-
Promonitor NRF560
Approval:
Weather proof, IP67 NEMA4X 0
TIIS Ex d IIB T4 X 1
FM XP Cl.I, Div.1, Gr.A-D 4
CSA Cl.I, Div.1, Gr.A-D 5
ATEX II 2G Ex d IIC T4 6
Special version, TSP-no. to be spec. 9
Cable Entry:
2x thread G1/2 A
2x thread NPT1/2 B
2x thread M20 D
Special version, TSP-no. to be spec. Y
Power Supply:
85-264VAC, 50/60Hz 3
20-62VDC, 20-55VAC, 50/60Hz 4
Special version, TSP-no. to be spec. 9
Mounting Bracket:
Not selected 0
Selected 1
Special version, TSP-no. to be spec. 9
Colour:
Blue 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
For mechanical tank gauges
LT and LTC series.
SPK: NSK
52007567
Analogue Transmitter AT1000
AT1-
Analogue Transmitter AT1000
Output:
4-20mA 1
10-50mA 2
0-1mA 3
0-20mA 4
0-10mVDC 5
0-1VDC 6
Special version, TSP-no. to be spec. 9
Power Type:
AC 1
DC 2
Alarm Output:
Page 25 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Not used 0
2-point 2
4-point 4
6-point 6
Approval:
Flame proof d2G4, TIIS + cable gland B
Flame proof d2G4, TIIS E
Weather proof IP65 W
Special version, TSP-no. to be spec. Y
Function:
Basic version 0
Special version, TSP-no. to be spec. 9
Power Supply:
100VAC, 50/60Hz 1
110VAC, 50/60Hz 2
200VAC, 50/60Hz 3
220VAC, 50/60Hz 4
24VDC 5
Special version, TSP-no. to be spec. 9
Cable Entry:
1x thread PF(G)3/4 A
2x thread PF(G)3/4 B
1x thread PF(G)1-1/2 C
1x thread PF(G)1-1/2, 1x PF(G)3/4 D
1x gland PF(G)3/4, TF16-11 E
2x gland PF(G)3/4, TF16-11 F
1x gland PF(G)1, TF22-15 G
1x thread M25 K
2x thread NPT3/4 R
Special version, TSP-no. to be spec. Y
Installation Gauge:
LT1100/LT1200/LT3100/LT3200 R:300mm low pressure LT version 1
LT1400/LT1600/LT3400/LT3600 R:300mm high pressure LT version 2
LTC2100 L:600mm 3
LTC2230/LTC2240 R:600mm 4
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
16m 4
20m 5
30m 6
Special version, TSP-no. to be spec. 9
Alarm Contact:
Not used 0
A = normal open 1
B = normal closed 2
C = transfer contact 3
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Page 26 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
For mechanical tank gauges
LT and LTC series.
SPK: NSK
52007817
Digital Transmitter TMD1 (TMD1000)
TMD1-
Digital Transmitter TMD1 (TMD1000)
Output 1:
Not selected 0
4-20mA 1
2-way 2-wire (MDP protocol) 2
BCD parallel 3
Sakura code parallel 4
2-way 2-wire (MIC, BBB protocol) 5
2-way 2-wire (V1 protocol) 6
Special version, TSP-no. to be spec. 9
Function:
HART input (NMT5xx, NRF560) B
Special version, TSP-no. to be spec. 9
Approval:
Weather proof IP65 0
Flame proof d2G4, TIIS 1
Flame proof d2G4, TIIS + cable gland 2
Output 2:
Not selected 0
4-20mA 1
4x alarm (open collector) 2
Monitor DRM 3
2x gauge operation command 4
2x gauge operation command, 6x outer equipment operation command 5
8x outer equipment operation command 6
4-20mA, 4x alarm (open collector) A
4-20mA, monitor DRM B
4x alarm (open collector), monitor DRM C
4-20mA, 4x alarm (open collector), monitor DRM D
4-20mA, 2x gauge operation command E
2x gauge operation command, monitor DRM F
Special version, TSP-no. to be spec. Y
Input:
Not used 0
4-20mA 1
4x status 2
1x spot temperature Pt100/JPt100 3
3x spot temperature Pt100/JPt100 4
Multi element average temperature 5
Multi spot average temperature 6
4-20mA, 1x spot temperature Pt100/JPt100 A
4-20mA, 3x point spot temperature Pt100/JPt100 B
4-20mA,multi element average temperature C
4-20mA, multi spot average temperature Pt100/JPt100 D
4x status, 1x spot temperature Pt100/JPt100 E
4x status, 3x spot temperature Pt100/JPt100 F
4x status, multi element average temperature G
4x status, multi spot average temperature H
4-20mA, 4x status J
4-20mA, 4x status, 1x spot temperature Pt100/JPt100 K
4-20mA, 4x status, 3x spot temperature Pt100/JPt100 L
4-20mA, multi element average temperature, 4x status M
4-20mA, multi spot average temperature, 4x status N
Page 27 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Special version, TSP-no. to be spec. Y
Power Supply:
60VAC, 50/60Hz 5
100VAC, 50/60Hz 1
110VAC, 50/60Hz 2
200VAC, 50/60Hz 3
220VAC, 50/60Hz 4
Special version, TSP-no. to be spec. 9
Colour:
Blue + white 1
Special version, TSP-no. to be spec. 9
Cable Entry:
A: PF(G)1-1/2, B: PF(G)3/4, C: PF(G)1, D: PF(G)1 0
A: NPT1-1/2, B: NPT3/4, C: NPT1, D: NPT1 1
A: none, C: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11, D: none 2
C: PF(G)1 TF22-15, D: PF(G)1 TF22-15 A: none, B: PF(G)3/4 TF16-11, 3
A: PF(G)1 TF22-15, D: none, B: PF(G)3/4 TF16-11, C: PF(G)1 TF22-15 4
A: PF(G)1 TF22-15, C: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11, D: PF(G)1 TF22-15 5
A: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 B: PF(G)3/4 TF16-11, C: PF(G)1 TF22-15, 7
A: none, B: PF(G)3/4 TF16-11, D: none C: PF(G)1-1/4 TF28-18 A
A: none, B: PF(G)3/4 TF16-11, C: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 B
C: PF(G)1-1/4 TF28-18, D: none, A: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11 C
A: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11, C: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 D
A: PF(G)1-1/4 TF28-18, B: PF(G)3/4 TF16-11, C: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 F
Special version, TSP-no. to be spec. 9
Communication:
Not used 0
2-way 2-wire (MIC, BBB protocol) 2
2-way 2-wire (MDP protocol) 3
2-way 2-wire (V1 protocol) 4
Emitter common A
Collector common B
Special version, TSP-no. to be spec. 9
Temperature Input:
Not used 0
Pt100, JIS=IEC, -50...+200oC 1
Pt100, JIS=IEC, +70...+350oC 2
JPt100, JIS, -50...+200oC 3
JPt100, JIS, +70...+350oC 4
NMT 5
Special version, TSP-no. to be spec. 9
Application:
LT11/LT12/LT31/LT32 3
LT14/LT16/LT34/LT36 4
LTC2230/LTC2240 5
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
For mechanical tank gauges
LT and LTC series.
SPK: NSK
52007816
Analogue Transmitter AT5000
AT500-
Page 28 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Analogue Transmitter AT5000
Alarm Output:
2-point 2
4-point 4
6-point 6
Function:
Basic version 0
Special version, TSP-no. to be spec. 1
Approval:
Flame proof d2G4, cable ground, TIIS B
Flame proof d2G4, TIIS E
Weather proof IP65 W
Special version, TSP-no. to be spec. Y
Level Gauge Combination:
LT1100/LT1200/LT3100/LT3200 R:300mm low pressure LT version 1
LT1400/LT1600/LT3400/LT3600 R:300mm high pressure LT version 2
LTC2100 L:600mm 3
LTC2230/LTC2240 R:600mm 4
Special version, TSP-no. to be spec. 9
Measuring Range:
2.5m 1
5m 2
10m 3
20m 5
30m 6
Special version, TSP-no. to be spec. 9
Alarm Contact:
A = normal open 1
B = normal closed 2
C = transfer contact 3
Cable Entry:
Thread PF(G)3/4 A
Thread PF(G)1-1/2 C
Gland PF(G)1, TF22-13 G
Gland PF(G)1, TF22-15 H
Gland PF(G)1-1/4, TF28-21 K
Thread NPT3/4 R
Thread NPT1 S
Thread M25 T
Special version, TSP-no. to be spec. Y
Colour:
Silver 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
SPK: NSS
52013134
Rail mounting kit, housing F22, NRF590
Rail mounting kit, housing F22, NRF590
Page 29 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
For tank gauges field mounted, for tank
gauges. It provides additional switching
of operation contacts of the gauge in
order to control the gauge's operation
(lift up displacer). SPK: NSS
016977-9000
Power + Control Switch NHS8
NHS8-
Power + Control Switch NHS8
Approval:
Weather proof IP67 1
Flame proof (JIS d3aG5) 2
Cable Entry:
2x thread PF(G)3/4 0
2x thread PF(G)1 1
2x thread NPT3/4 2
2x thread NPT1 3
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Used for start up, calibration and
service of the level gauges TGM5
and TMD (in combination with LT1x).
Provides direct access to all parameters
and values stored in the gauge.
Connected to the gauge with an optical
connector included.
SPK: NSS
52007821
Hand Held Terminal HHT2
HHT2-
Hand Held Terminal HHT2
Approval:
Intrinsically safe, i2G3 TIIS E
Cable:
1m 0
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
For tank level gauge;
high pressure version.
Maintenance chamber is recommended
for use with tank level gauges
in order to allow maintenance
(removing displacers),
while tank is in service.
Standard chamber is 6" flange,
with bolts&packing for NMS connection.
SPK: NSS
52004545
Calibration Chamber NHC4HP
NHC4HP-
Calibration Chamber NHC4HP
Process Connection:
10K 150A RF, flange JIS B2220 A
10K 150A FF, flange JIS B2220 C
20K 150A RF, flange JIS B2220 E
6" 150lbs RF, flange ANSI B16.5 G
6" 300lbs RF, flange ANSI B16.5 J
Page 30 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
DN150 PN10 B1, flange EN1092-1 (DIN2527 B) L
DN150 PN25 B1, flange EN1092-1 (DIN2527 B) N
150A 150lbs RF, flange JPI 7S-15 Q
150A 300lbs RF, flange JPI 7S-15 S
Special version, TSP-no. to be spec. Y
Pipe Material; Flange Material:
STPG370; SS400 2
SUS304TP; SUS304 3
Special version, TSP-no. to be spec. 9
Bolts, Packing:
Not used 0
SUS304, Valker #6502 1
Special version, TSP-no. to be spec. 9
Pressure Gauge, Relief Valve:
Selected 1
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
For tank level gauge;
low pressure version.
Maintenance chamber is recommended
for use with tank level gauges
in order to allow maintenance
(removing displacers),
while tank is in service.
Standard chamber is 6" flange,
with bolts&packing for NMS connection.
SPK: NSS
52004544
Calibration Chamber NHC4LP
NHC4LP-
Calibration Chamber NHC4LP
Process Connection:
10K 150A RF, flange JIS B2220 A
10K 150A FF, flange JIS B2220 C
6" 150lbs RF, flange ANSI B16.5 G
DN150 PN10 B1, flange EN1092-1 (DIN2527 B) L
150A 150lbs RF, flange JPI 7S-15 Q
Special version, TSP-no. to be spec. Y
Pipe Material; Flange Material:
AC4A; AC4A 1
SUS304TP; SUS304 3
Special version, TSP-no. to be spec. 9
Bolts, Packing:
Not used 0
SUS304, Valker #6502 1
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
The gauge connection of the reducing
flange is always in the same flange
norm like the process connection, but
with 3" resp. DN80 size.
The reducing flange is equipped with
stud bolts only for the gauge connec-
tion side.
SPK: NSS
017408-9000
Reducing Flange NHF4
NHF4-
Page 31 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Reducing Flange NHF4
Process Connection:
10K 150A RF, flange JIS B2220 A
10K 150A FF, flange JIS B2220 C
20K 150A RF, flange JIS B2220 E
6" 150lbs RF, flange ANSI B16.5 G
6" 300lbs RF, flange ANSI B16.5 J
DN150 PN10 B1, flange EN1092-1 (DIN2527 B) L
DN150 PN25 B1, flange EN1092-1 (DIN2527 B) N
150A 150lbs RF, flange JPI 7S-15 Q
150A 300lbs RF, flange JPI 7S-15 S
Special version, TSP-no. to be spec. Y
Flange Material:
Mild Steel (JIS SS41) 0
SUS304 1
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Standard ball valve with JIS flanges.
For body in mild steel and in SS304,
ball material is SS304. For body in
SS316, ball material is SS316.
Seat material is PTFE. SPK: NSS
017407-9000
Ball Valve NHV4J
NHV4J-
Ball Valve NHV4J
Process Connection; Body:
10K 80A RF; Steel flange JIS B2220 C11
10K 150A RF; Steel flange JIS B2220 C12
20K 80A RF; Steel flange JIS B2220 C21
20K 150A RF; Steel flange JIS B2220 C22
10K 80A RF; SS316 flange JIS B2220 S11
10K 150A RF; SS316 flange JIS B2220 S12
20K 80A RF; SS316 flange JIS B2220 S21
20K 150A RF; SS316 flange JIS B2220 S22
10K 80A RF; SS304 flange JIS B2220 H11
10K 150A RF; SS304 flange JIS B2220 H12
20K 80A RF; SS304 flange JIS B2220 H21
20K 150A RF; SS304 flange JIS B2220 H22
Special version, TSP-no. to be spec. Y99
Ball Type:
Full bore A
Reduced bore B
Special version, TSP-no. to be spec. Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Page 32 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Standard ball valve with ANSI flanges.
Ball material is SS304, seat material is
PTFE.
SPK: NSS
017406-9000
Ball Valve NHV4A
NHV4A-
Ball Valve NHV4A
Process Connection; Body:
3" 150lbs RF; Steel casting flange ANSI B16.5 C31
3" 300lbs RF; Steel casting flange ANSI B16.5 C33
6" 150lbs RF; Steel casting flange ANSI B16.5 C61
6" 300lbs RF; Steel casting flange ANSI B16.5 C63
3" 150lbs RF; SS304 flange ANSI B16.5 S31
3" 300lbs RF; SS304 flange ANSI B16.5 S33
6" 150lbs RF; SS304 flange ANSI B16.5 S61
6" 300lbs RF; SS304 flange ANSI B16.5 S63
Special version, TSP-no. to be spec. Y99
Ball Type:
Full bore A
Reduced bore B
Special version, TSP-no. to be spec. Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Average temperature converter
for existing temperature sensor
RCV1100/1200
HART output to NMS servo gauge.
SPK: NST
52013913
Temperature Converter RCV-NMT NCT530
NCT530-
Temperature Converter RCV-NMT NCT530
Converter:
Integrated type 6
External type 7
Approval:
Weather proof IP67 0
Ex d IIB T4, TIIS 1
Special version, TSP-no. to be spec. 9
Cable Entry:
Not selected B
2x thread G1/2 A
2x thread G3/4 C
2x thread G1/2, G3/4, integrated type D
1x gland G1/2, integrated type E
1x gland G3/4, integrated type F
Special version, TSP-no. to be spec. Y
Element Type:
Pt100, MRT 1
Pt100, MST 2
JPt100, MRT 3
JPt100, MST 4
Special version, TSP-no. to be spec. 9
Page 33 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Range:
-50...+200oC liquid/gas temp. 1
Special version, TSP-no. to be spec. 9
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Simple temperature measurement for
non-custody transfer application.
Temp. data in HART loop connection
to NRF590/NMS5.
SPK: NST
70104682
Prothermo NMT532
NMT532-
Prothermo NMT532
Approval:
FM IS Cl.I Div.1 Gr.A-D 7
CSA IS Cl.I Div.1 Gr.A-D 8
ATEX Ex ia IIB T4-T6 B
IEC Ex ia IIB T2-T6 Ga F
Cable Entry:
Thread NPT1/2 B
Thread M20 D
Process Connection:
2" 150lbs RF, 304 flange ANSI B16.5 1
DN50 PN10 B1, 304 flange EN1092-1 (DIN2527 C) 2
Special version, TSP-no. to be spec. 9
Probe Length; Element; Interval:
xxx mm; 2x Pt100; 2m 022
xxx mm; 3x Pt100; 2m 032
xxx mm; 4x Pt100; 2m 042
xxx mm; 5x Pt100; 2m 052
xxx mm; 6x Pt100; 2m 062
xxx mm; 2x Pt100; 3m 023
xxx mm; 3x Pt100; 3m 033
xxx mm; 4x Pt100; 3m 043
xxx mm; 5x Pt100; 3m 053
xxx mm; 6x Pt100; 3m 063
Additional Option:
Not selected A
Anchor weight, high profile B
Anchor weight, low profile C
Tension wire, wire hook, NPT1 top anchor D
Tension wire, wire hook, R1 top anchor F
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Precision temperature measurement for
custody transfer application.
Water I/F measurement under oil layer
Both temp. & WB data in single HART loop
Connection to NMS/NRF590. SPK: NST
56004109
Prothermo NMT539
NMT539-
Page 34 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Prothermo NMT539
Approval:
Weather proof, IP65 NEMA4X 0
FM IS Cl.I Div.1 Gr.C-D 7
CSA IS Cl.I Div.1 Gr.C-D 8
ATEX Ex ia IIB T2-T6 B
TIIS Ex ia IIB T2 C
TIIS Ex ia IIB T4 A
TIIS Ex d (ia) IIB T4 E
IEC Ex ia IIB T2-T6 Ga F
Special version, TSP-no. to be spec. 9
Application:
Converter 0
Temperature, converter 1
Temperature, water bottom, converter 3
Temperature, converter, (PTB type approval) 4
Temperature, converter, water bottom, (PTB type approval) 5
Special version, TSP-no. to be spec. 9
Temperature Measuring Range:
Not selected 0
-20...+100oC 5
-40...+100oC 1
-20...+235oC 6
-55...+235oC 2
-170...+60oC 3
-20...+120oC (PTB type approval only) 4
Special version, TSP-no. to be spec. 9
Water Bottom Measuring Range:
Not selected 0
1m/3.3ft 1
2m/6.6ft 2
Special version, TSP-no. to be spec. 9
Cable Entry:
Thread G1/2 A
Thread NPT1/2 B
Thread M20 D
Special version, TSP-no. to be spec. Y
Process Connection:
10K 50A RF, 316 flange JIS B2220 0
2" 150lbs RF, 316 flange ANSI B16.5 1
DN50 PN10 B1, 316 flange EN1092-1 (DIN2527 B) 2
50A 150lbs RF, 316 flange JPI 7S-15 3
Universal coupling, G3/4, (converter only) 4
Thread M20 (converter only) 5
Special version, TSP-no. to be spec. 9
Temperature Element:
2x Pt100 A
3x Pt100 B
4x Pt100 C
5x Pt100 D
6x Pt100 E
7x Pt100 F
8x Pt100 G
9x Pt100 H
10x Pt100 J
11x Pt100 K
12x Pt100 L
13x Pt100 M
14x Pt100 N
15x Pt100 O
16x Pt100 P
Not selected Q
Page 35 / 36
Configurator 2011-2012 Endress+Hauser Consult AG
Kägenstrasse 2
CH - 4153 Reinach
Special version, TSP-no. to be spec. Y
Temperature Element Spacing:
UK standard (converter only) 7
1m / 39" 3
1.5m / 59" 2
2m / 79" 1
3m / 118" 5
Equally spaced, defined by length 4
Not selected 6
Special version, TSP-no. to be spec. 9
Probe Length:
xxx mm A
Not selected B
Special version, TSP-no. to be spec. Y
Mounting Attachment:
Not selected A
Anchor weight, high profile (D120) B
Anchor weight, low profile (hexagon H41) C
Tension wire, wire hook, NPT1 top anchor D
Tension wire, wire hook, R1 top anchor F
Special version, TSP-no. to be spec. Y
>>>Marking: (optional)
Tagging (TAG), see additional spec. 1
Page 36 / 36