TRUTEMP Temperature Sensor Introduction
TRUTEMP Plastics And General Purpose Sensors
Plastics And General Purpose Sensor IntroductionStyle GA Adjustable Bayonet Sensors
Style GAM Metric Adjustable Bayonet Sensors
Style GB Fixed Bayonet SensorsStyle GF Fixed Probe Sensors
Style GC Compression Mount SensorsStyle GH Hex Fitting Mount Sensors
Style GG Grommet Mount SensorsStyle GL Lug Mount Sensors
Style GS Shim Mount Sensors
Style GP Pad Mount SensorsStyle GR Ring Mount Sensors
Style GH Hose Clamp SensorsStyle GN Newbury Nozzle Sensors
Style GNN Non-Immersion Nozzle Sensors
Style GNI Immersion Nozzle SensorsStyle GMF Fixed Melt Bolt Sensors
Style GMA One Time Adjustable Melt Bolt SensorsStyle GFX Flexible Sensor Extensions
TRUTEMP Drawn Metal Sheathed Cable Sensors
Drawn Metal Sheathed Cable Sensor IntroductionStyle MS Cable Sensor With Stripped End Termination
Style MC Cable Sensor With Connector TerminationStyle MW Cable Sensor With Wafer Termination
Style MH Cable Sensor With Head Termination
Style MM Cable Sensor With Metal Transition Lead TerminationStyle MT Cable Sensor With Molded Transition Lead Termination
Style MMID Miniature Industrial Duty ThermocouplesStyle MHID Miniature Industrial Duty Thermocouples
TRUTEMP Swaged Metal Sheathed Cartridge SensorsSwaged Metal Sheathed Cartridge Sensor Introduction
TRUTEMP Welded Wire And Ceramic Beaded Thermocouples
TRUTEMP Sensor Accessories
Page 3-1
Page 3-3Page 3-5
Page 3-6
Page 3-7Page 3-8
Page 3-9Page 3-10
Page 3-11Page 3-11
Page 3-12
Page 3-12Page 3-13
Page 3-13Page 3-14
Page 3-14
Page 3-15Page 3-16
Page 3-17Page 3-18
Page 3-19Page 3-21
Page 3-22Page 3-23
Page 3-24
Page 3-25Page 3-26
Page 3-27Page 3-29
Page 3-29
Page 3-37
Page 3-39
DURATHERMProcessing Systems, Inc.
SECTIONINDEX
"TRUTEMP" TEMPERATURE SENSORS
-
8/11/2019 Termopares (Catalogo Completo) (2)
2/50
DURATHERMProcessing Systems, Inc.
3-1
TRUTEMP Temperature Sensors........For Accurate And Reliable Temperature Control.
The TRUTEMP family of temperature sensing devices includes
thermocouples, resistance temperature detectors and
thermistors in a variety of industrial and laboratory qualityassemblies. A variety of construction options are available foreach sensor configuration offered. These options include
assorted calibrations, junction designs and terminations.
Optional lead insulation materials and protection systems permitcustom tailoring of the sensor to the application.
Versatile Temperature Sensor Styles....
11111TRUTEMP Plastics And General Purpose Sensors
These popular sensor assemblies are designed for use inmedium duty environments involving application temperaturesof 900F. maximum. Standard constructions feature high quality,
stranded wire with duplex fiberglass insulation. Special wire
sizes and constructions, in an assortment of insulation materialsand protective coverings, are available.
22222TRUTEMP Drawn Metal Sheath Cable Sensors
Mineral insulated, sensor assemblies are designed for
demanding temperature measurement applications. Thedurable, metal-sheathed, mineral insulated cable protects the
sensor elements in high temperature environments and
provides superior abuse resistance for physically demandingindustrial applications.
33333TRUTEMP Swaged Metal Sheath Cartridge Sensors
Mineral insulated, cartridge sensors are swage compacted
assemblies featuring protective integral lead systems. These
rugged assemblies are available in wide range of diametersand lengths and are suitable for use in any application requiring
a combination of precision sensing and durability.
44444TRUTEMP Process Sensors And Protection Tubes
Welded bare wire and ceramic bead insulated sensors can beutilized in a wide assortment of applications. While these
assemblies are commonly used in their unprotected form, they
are often used in conjunction with various styles of protectiontubes and thermowell assemblies. Duratherm stocks a complete
line of common thermowells and will manufacture specialthermowells when required. Our CNC equipped machine shop
can produce any desired thermowell configuration.
-
8/11/2019 Termopares (Catalogo Completo) (2)
3/50
"TRUTEMP" SENSOR ASSEMBLIES
3-2
TRUTEMP Sensor Element Specifications
For critical applications, Duratherm can provide complete
calibration, traceable to the National Institute of Standards and
Technology. Equipment is available to test your sensors ovea wide range of temperatures. When calibration is requestedtested materials and components will be tagged and supplied
with a calibration report. If calibration services are required
contact our sales office for details.
"TRUTEMP" sensors are manufactured to rigid specifications.
Thermocouple materials and testing conform to standard
tolerances of ANSI Circular MC96.1-1982. Platinum RTDelements conform to DIN specification 43760, with a
temperature coefficient of .000385 ohms/ohm/C. Specialtolerances and specifications are available on a special orderbasis, at additional cost.
Thermocouple Specifications And Initial Calibration Tolerances For Standard Temperature Ranges
Thermocouple Specifications And Initial Calibration Tolerances For Cryogenic Temperature Ranges***
* Trade Names - Chromel and Alumel - Hoskins Manufacturing Co.** When tolerances are given in two values, appropriate tolerances are determined by selecting the larger of the two values shown.*** Thermocouples are normally calibrated for standard temperature ranges. If cryogenic use is intended, your order must specifically request cryogenic tolerances
C/TISNA
noitarbilaC
eriWISNA
noitangiseD
roloCISNA
sedoC
edarTdnAcireneGlacipyT
*semaN
citengaM
seitreporP
egnaRerutarepmeT **secnareloT
.FseergeD .CseergeD dradnatS laicepS
TPT eulB reppoC enoN
266-23 053-0 rOC0.1
%57.0
rOC5.0
%4.0NT deR natnatsnoC enoN
JPJ etihW norI gnortS
2831-23 057-0 rOC2.2
%57.0rOC1.1
%4.0NJ deR natnatsnoC enoN
EPE elpruP lemorhC enoN
2561-23 009-0 rOC7.1
%5.0
rOC1.1
%4.0NE deR natnatsnoC enoN
KPK wolleY lemorhC enoN
2822-23 0521-0 rOC2.2
%57.0
rOC1.1
%4.0NK deR lemulA kaeW
RPR kcalB muidohR%31munitalP enoN
2642-23 0541-0 rOC5.1
%52.0rOC6.0
%1.0NR deR munitalP enoN
SPS kcalB muidohR%01munitalP enoN
2462-23 0541-0 rOC5.1
%52.0
rOC6.0
%1.0NS deR munitalP enoN
BPB yerG muidohR%03munitalP enoN
2903-8951 0071-078 C5.0 A/NNB deR muidohR%6munitalP enoN
NPN egnarO lisorciN enoN
2822-23 0521-0 rOC2.2
%57.0rOC1.1
%4.0NN deR lisiN enoN
C/TISNA
noitarbilaC
eriWISNA
noitangiseD
roloCISNA
sedoC
edarTdnAcireneGlacipyT
*semaN
citengaM
seitreporP
egnaRerutarepmeT **secnareloT
.FseergeD .CseergeD dradnatS laicepS
TPT eulB reppoC enoN
23-823- 0-002- rOC0.1
%5.1 A/N
NT deR natnatsnoC enoN
EPE elpruP lemorhC enoN
23-823- 0-002- rOC7.1
%0.1 A/N
NE deR natnatsnoC enoN
KPK wolleY lemorhC enoN
23-823- 0-002- rOC2.2
%0.2 A/N
NK deR lemulA kaeW
erutarepmeT ecnatsiseR
eulaV
secnareloT06734NID secnareloTlairtsudnI
AssalC BssalC CssalC
C002-
C001-
C0
C001
C002
C003
C004
C005
C006
C056
smhO94.81
smhO52.06
smhO00.001
smhO05.831
smhO48.571
smhO20.212
smhO40.742
smhO09.082
smhO95.313
smhO15.923
C55.0
C53.0
C51.0
C53.0
C55.0
C57.0
C59.0
C51.1
C53.1
C54.1
smhO42.0
smhO41.0
smhO60.0
smhO31.0
smhO02.0
smhO72.0
smhO33.0
smhO83.0
smhO34.0
smhO64.0
C3.1
C8.0
C3.0
C8.0
C3.1
C8.1
C3.2
C8.2
C3.3
C6.3
smhO65.0
smhO23.0
smhO21.0
smhO03.0
smhO84.0
smhO46.0
smhO97.0
smhO39.0
smhO60.1
smhO31.1
C72.2
C77.1
C72.1
C77.1
C72.2
C77.2
C72.3
C77.3
C72.4
C25.4
smhO51.1
smhO17.0
smhO05.0
smhO76.0
smhO38.0
smhO89.0
smhO01.1
smhO22.1
smhO23.1
smhO63.1
-
8/11/2019 Termopares (Catalogo Completo) (2)
4/50
DURATHERMProcessing Systems, Inc.
3-3
"TRUTEMP" Plastics And General Purpose Sensors
66666Extended Style and Size Selection.The large range of sensorconfigurations and sizes offered meets the needs of most
common applications. Single and multiple elementconfigurations can be readily manufacture to suit any special
application requirements.
The "TRUTEMP" plastics and general purpose sensors are
intended for use in medium duty processing applicationsinvolving exposure temperatures of up to 900F. The standardconstruction consists of an appropriate pair of insulated leads
formed into a thermocouple junction or attached to RTD sensorelements. This sensor assembly is typically installed into
assorted combinations of tubes and fittings to form a complete
sensor assembly.
55555High Quality Sensor Elements.Available sensor types include
all standard base metal thermocouple alloys as well as an
assortment of RTD sensor elements. Standard thermocouplesensors are constructed to the standard limits of error as
specified by ANSI MC96.1-1982. Special tolerances to ANSIMC96.1-1982 can also be supplied when required.
44444Oxidation Resistant Construction. Standard tube type
thermocouples feature a 304 series stainless steel sheath.
Fittings for all configurations can be supplied in a variety ofmaterials. Standard fitting selections include stainless steel,
nickel plated steel, nickel plated brass, brass and copper.
33333Durable, Flex Resistant Lead Systems. All sensor
configurations feature securely anchored leads. A variety ofstandard lead protection options enables matching of sensor
lead systems to application requirements. Most sensorconfigurations allow a choice of several lead exit angles.
22222Versati le Construction Styles. The plastics and general
purpose sensors are manufactured in a wide selection of
standard and special purpose mounting configurations. Customversions of these popular sensors can be manufactured to
customer specifications when required.
11111High Strength, Durable Design.Each sensor style has been
engineered to provide an optimum blend of accuracy, strength
and economy. Superior design and precision assembly ensureoptimum sensor performance.
-
8/11/2019 Termopares (Catalogo Completo) (2)
5/50
3-4
"TRUTEMP" PLASTICS AND GENERAL PURPOSE SENSORS
Plastics And General Purpose Sensor Specifications And Application Data
UngroundedRadius Tip
GroundedRadius Tip
UngroundedDrill Tip
GroundedDrill Tip
GroundedFlat Tip
UngroundedFlat Tip
ExposedUngrounded
Standard Junction Styles
Standard Plastics And General Purpose Sensors
Duratherm maintains a large inventory of common plastics andgeneral purpose sensors and can provide quick shipment of
both standard and custom sensors. The highly versatile plasticsand general purpose sensors are supplied in a virtually unlimited
number of application specific constructions. These low cost
sensors can be readily manufactured with any desiredcombination of custom design features. Special fittings, flanges
and connectors are supplied on a routine basis. Our modernCNC equipped machine shop ensures in-house control of
quality and delivery of component parts.
Duratherm has produced thousands of unique, plastics and
general purpose sensor designs and would welcome the
opportunity to quote, design and manufacture any customsensor your application requires.
Plastic injection molds and equipment
Packaging equipment
Thermoset mold and platen heating
Food processing equipment
Refrigeration temperature control
Oven and hot plate temperature control
Radiant heating control applications
Pipe trace heating control
Liquid temperature measurement and control
Deicing systems
Vapor cleaning and degreasing systems
Plastic extrusion dies and equipment
Industrial Processing
Medical and dental equipment
Plating baths
Drying Equipment
Photographic and X-ray film developing systems
Plastics And General Purpose Sensor Applications
Junction Configurations
Duratherm offers three basic thermocouple junctions. Exposedjunctions have the best thermal response but is unprotected
Grounded junctions offer the next best thermal response and
the junction is fully protected. Ungrounded junctions featureslightly lower thermal response than the grounded type, bu
are protected and also electrically isolate the junction from thesensor sheath. Grounded and ungrounded junctions of tube
style sensors can be provided with shaped tip configurationsto enhance response. The drawing below illustrates the
standard junction styles as they appear on tube type genera
purpose sensors. The junctions of other general purposesensors are also available in the basic three types but will diffe
in appearance depending on sensor construction.
General Purpose Sensor Insulation Materials
The majority of general purpose sensors utilize the thermal andelectrical properties of the wire insulation to isolate the senso
elements from the mechanical portion of the sensor. For thisreason it is necessary to select the wire on the basis of senso
application temperature. If you have special requirements
requiring the use of extension wire rated at temperatures belowthe sensor exposure temperature, contact our engineering
department for design recommendations.
Calibration Tolerances
"TRUTEMP" plastics and general purpose thermocouple senso
assemblies meet or exceed the standard tolerances of ANS
Circular MC96.1-1982. Special tolerances meeting the standardsof ANSI MC96.1-1982 can also be supplied when required"TRUTEMP" plastics and general purpose RTD senso
assemblies meet or exceed the standard tolerances of DIN
specification 43760. For critical applications, Duratherm canprovide complete calibration, traceable to the National Institute
of Standards and Technology. Equipment is available to testyour sensors over a wide range of temperatures. When
calibration is requested, tested materials and components wil
be tagged and supplied with a calibration report. If calibrationservices are required, contact our sales office for details.
-
8/11/2019 Termopares (Catalogo Completo) (2)
6/50
DURATHERMProcessing Systems, Inc.
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Probe Mounting LengthFractional In. By Letter CodeOptional If Standard 1/2" ProbeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Style GA Adjustable Bayonet Sensors
The popularity of adjustable bayonet sensors is due, in large part, tothe inventory reducing design. Each sensor in this series can be quicklyadjusted to suit a variety of application and depth requirements.
Fiberglass lead and stainless steel wire braided lead types feature aten inch compression spring for cap adjustment. The spiral armor hoseprovides the cap adjustment feature on the armor hose configurations.Flex resistant stranded leads with fiberglass insulation are standard onall adjustable bayonet styles and are available in a range of leadprotection styles.
Style CodeGeneral PurposeAdjustable Bayonet
Probe Diameter Code2 - 1/8 Special3 - 3/16 Standard4 - 1/4 Special
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - Iron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole InchesOptional If LessThan 1 Inch
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & ArmorK - Kapton LeadsT - Teflon Leads
Selection And Ordering
All adjustable and fixed bayonet sensor styles can be fabricated toyour specifications on a same day shipment basis. To order by productnumber, replace the codes in the product number examples with theappropriate codes detailing your requirements.
Style GA Sensor Product Number Definition
GA 3 J GD 0 H 48 B 1
3-5
Style "GA" Adjustable Bayonet SensorType "L" Fiberglass Leads Shown
Style "GA" Adjustable Bayonet SensorType "B" Braid Protected Leads Shown
Style "GA" Adjustable Bayonet SensorType "A" Armor Protected Leads Shown
-
8/11/2019 Termopares (Catalogo Completo) (2)
7/50
"TRUTEMP" PLASTICS AND GENERAL PURPOSE SENSORS
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Probe Mounting LengthFractional In. By Letter CodeOptional If Standard 1/2" ProbeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Style GAM Metric Adjustable Bayonet Sensors
The metric adjustable bayonet sensors are offered in sizes suitable formost machines utilizing metric size bayonet fittings. Each sensor inthis series can be quickly adjusted to suit a variety of application and
depth requirements. Fiberglass lead and stainless steel wire braidedlead types feature a ten inch compression spring for cap adjustment.The spiral armor hose provides the cap adjustment feature on the armorhose configurations. Flex resistant stranded leads with fiberglassinsulation are standard on all adjustable bayonet styles and are availablein a range of lead protection styles.
Style CodeGeneral Purpose MetricAdjustable Bayonet
Probe Diameter Code6 - 6 mm Tip & Spring With 12.5 mm ID Double Pin Cap8 - 8 mmTip & Spring With 15 mm ID Double Pin Cap
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - I ron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsCT - Ceramic Fast Response TipGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole InchesOptional If LessThan 1 Inch
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & ArmorK - Kapton LeadsT - Teflon Leads
Selection And Ordering
All adjustable and fixed bayonet sensor styles can be fabricated toyour specifications on a same day shipment basis. To order by producnumber, replace the codes in the product number examples with theappropriate codes detailing your requirements. Additional speciametric style sensors can be manufactured, contact Duratherm fodetails.
Style GAM Sensor Product Number Definition
GAM 8 J GD 0 H 48 B 1
3-6
Style "GAM" Adjustable Bayonet SensorType "L" Fiberglass Leads Shown
Style "GAM" Adjustable Bayonet SensorType "B" Braid Protected Leads Shown
Style "GAM" Adjustable Bayonet SensorType "A" Armor Protected Leads Shown
-
8/11/2019 Termopares (Catalogo Completo) (2)
8/50
DURATHERMProcessing Systems, Inc.
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
Probe Extension LengthFractional In. By Letter Code1 1/4" Extension is StandardFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Style GB Fixed Bayonet Sensors
The fixed bayonet sensor configuration provides a positive visualreference as to junction location within the drilled well. Customerspecified variations in lead exit angle and extension length permits ideal
positioning of the leads in relation to surfaces and obstructions.
Style GB Sensor Product Number Definition
GB 3 3 J GD 0 H 3 Z 48 B 1
Probe Diameter Code2 - 1/8 Special3 - 3/16 Standard4 - 1/4 Special
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - Iron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole Inches
Lead Exit Code0 - 0 Deg. Exit3 - 45 Deg. Exit6 - 90 Deg. Exit
Style CodeGeneral PurposeFixed Bayonet
Probe Extension LengthIn Whole Inches
Probe Mounting LengthIn Fractional In. By Letter Code
3-7
Style "GB" With Type "0" 0 Deg. Lead ExitType "L" Fiberglass Leads Shown
Style "GB" With Type "3" 45 Deg. Lead ExitType "B" Wire Braid Protected Leads Shown
Style "GB" With Type "6"90 Deg. Lead Exit
Type "A" Armor
Protected Leads Shown
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & ArmorK - Kapton LeadsT - Teflon Leads
-
8/11/2019 Termopares (Catalogo Completo) (2)
9/50
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
Probe Extension LengthFractional In. By Letter Code1 1/4" Extension is StandardFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Style GF Fixed Probe Sensors
Fixed probe sensors are useful in a wide variety of solid, gas and liquidtemperature applications. Probes can be used in drilled holes or directlyimmersed in liquids. Optional lead exit angles allow optimum lead
positioning relative to wire channels and surfaces.
Style GF Sensor Product Number Definition
GF 3 3 J GD 0 H 3 Z 48 B 1
Probe Diameter Code2 - 1/8 Special3 - 3/16 Standard4 - 1/4 Special
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - I ron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole Inches
Lead Exit Code0 - 0 Deg. Exit3 - 45 Deg. Exit6 - 90 Deg. Exit
Style CodeGeneral PurposeFixed Probe
Probe Extension LengthIn Whole Inches
Probe Mounting LengthIn Fractional In. By Letter Code
3-8
Style "GF" With Type "0" 0 Deg. Lead ExitType "L" Fiberglass Leads Shown
Style "GF" With Type "3" 45 Deg. Lead ExitType "B" Wire Braid Protected Leads Shown
Style "GF" With Type "6"90 Deg. Lead Exit
Type "A" Armor
Protected Leads Shown
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & ArmorK - Kapton LeadsT - Teflon Leads
-
8/11/2019 Termopares (Catalogo Completo) (2)
10/50
DURATHERMProcessing Systems, Inc.
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
Probe Extension LengthFractional In. By Letter Code1 1/4" Extension is StandardFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Style GC Compression Mount Sensors
The adjustable compression sensor includes a compression fitting tosecure and seal the probe in place. This mounting can be used withsolids, liquids and gases. Lead exit angle options simplify wire routing.
Lead styles include plain and protected configurations. Standard fittingis 1/8" NPT brass. Please specify if other material or size is required.
Style GC Sensor Product Number Definition
GC B 3 3 J GD 0 H 3 Z 48 B 1
Probe Diameter Code2 - 1/8 Special3 - 3/16 Standard4 - 1/4 Special (Specify Fitting Size)5 - 5/16 Special (Specify Fitting Size)6 - 3/8 Special (Specify Fitting Size)
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - Iron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan Dual
RT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole Inches
Lead Exit Code0 - 0 Deg. Exit3 - 45 Deg. Exit
6 - 90 Deg. Exit
Style CodeGeneral PurposeCompression Mount
Probe Extension LengthIn Whole Inches
Probe Mounting LengthIn Fractional In. By Letter Code
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & ArmorK - Kapton LeadsT - Teflon Leads
3-9
Style "GC" With Type "0" 0 Deg. Lead ExitType "L" Fiberglass Leads Shown
Style "GC" With Type "6"90 Deg. Lead Exit
Type "A" ArmorProtected Leads Shown
Style "GC" With Type "3" 45 Deg. Lead ExitType "B" Wire Braid Protected Leads Shown
Fitting Material CodeB - Brass StandardS - Stainless Steel Special
-
8/11/2019 Termopares (Catalogo Completo) (2)
11/50
"TRUTEMP" PLASTICS AND GENERAL PURPOSE SENSORS
3-10
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
Probe Extension LengthFractional In. By Letter Code1 1/4" Extension is StandardFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Style GH Hex Fitting Mount Sensors
The hex fitting mount sensor includes a permanantly mounted hex fittingto secure the probe and/or secure a head to the sensor. This fitting canbe used with solids, liquids and gases. Lead styles include plain and
protected configurations. The standard hex fitting is 1/8" NPT brass.Please specify if other material or size is required.
Style GH Sensor Product Number Definition
GH B D 1 3 J GD 0 H 3 Z 48 B 1
Probe Diameter Code2 - 1/8 Special3 - 3/16 Standard4 - 1/4 Special (Specify Fitting Size)5 - 5/16 Special (Specify Fitting Size)6 - 3/8 Special (Specify Fitting Size)
Hex Fitting Size
Style CodeGeneral PurposeHex Fitting Mount
Probe Extension LengthIn Whole Inches
Probe Mounting LengthIn Fractional In. By Letter Code Lead Length
Specify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & ArmorK - Kapton LeadsT - Teflon LeadsH1 - Head 1/2" NPT ExitH2 - Head 3/4" NPT Exit
Fitting Mat'l CodeB - Brass StandardS - Stainless Steel
Probe Mounting LengthIn Whole Inches
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - I ron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Hex Fitting Type
1 - 1/8 NPT2 - 1/4 NPT3 - 3/8 NPT
4 - 1/2 NPT5 - 3/4 NPT6 - 1" NPT
R - Reverse Single
S - SingleD - Double
Style "GH" With Type "S" SingleHex Fitting And Armor Style Leads
Style "GH" WithType "R" ReverseSingle Hex FittingAnd Head Style
Termination
Style "GH" With Type "D" Double HexFitting And Head Style Termination
-
8/11/2019 Termopares (Catalogo Completo) (2)
12/50
DURATHERMProcessing Systems, Inc.
Style GG Grommet Mount Sensors
Style GG Sensor Product Number Definition
GG 2 2 J GC 48 L 1
Style GL Lug Mount Sensors
Style GL Sensor Product Number Definition
Lug style sensors provide simple installation in applications notrequiring the precision of more elaborate sensor configurations. Thesesensors are readily secured to most surfaces with preexisting fasteners.A variety of plain lead and protected lead configurations are available.
Grommet style sensors provide simple installation in applicationsrequiring the fast response and precision of a low mass sensorconfiguration. These sensors are readily secured to most surfaces
with preexisting fasteners. A variety of plain lead and protected leadconfigurations are available.
Style "GL" Lug SensorType "B" Braid Protected Leads Shown
Style "GG" Grommet SensorType "L" Plain Leads Shown
GL 4 2 J GC 48 L 1
Style CodeGeneral PurposeLug Mount
Lug Dimensions2 - #63 - #84 - #10 Standard5 - 1/46 - 3/8
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 Wire
Lead ProtectionL - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor Hose
4 - Standard Female Jack & Bracket5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Junction Style & AttachmentType GC Is StandardGC - Grounded And CrimpedGB - Grounded And Brazed
Lead LengthSpecify In Inches
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/Constantan
Lead ProtectionL - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire Braid
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket
3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Junction Style & AttachmentType GC StandardGC - Grounded And Crimped
Lead LengthSpecify In Inches
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BX Connector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket
Grommet Material2 - Brass
Grommet Dimensions2 - #00 .187 I.D .430 O.D.3 - #0 .240 I.D. .545 O.D.4 - #1 .286 I.D. .687 O.D.5 - #2 .362 I.D. .815 O.D.6 - #3 .433 I.D. .970 O.D.
Style CodeGeneral PurposeGrommet Mount
Lug Material2 - Nickel Plated Steel Standard3 - Nickel Plated Copper4 - Monel5 - Nickel
3-11
-
8/11/2019 Termopares (Catalogo Completo) (2)
13/50
3-12
Style GS Shim Mount Sensors
Shim mount sensors are designed for minimum profile and can beinstalled between components for measurement of surfacetemperatures. Shim sensors in dimensions other than those shown
can be manufactured when required.
Style GS Sensor Product Number Definition
GS 3 1 J GB 48 L 1
Style "GS" Shim SensorType "L" Plain Leads Shown
Style GP Pad Mount Sensors
Pad mount sensors are designed for installation between flat machinedcomponents for measurement of surface temperatures. Pad sensorsin dimensions other than those shown can be manufactured whenrequired.
Style GP Sensor Product Number Definition
GP 3 1 J GB 48 L 1
Style "GP" Pad SensorType "B" Braid Protected Leads Shown
"TRUTEMP" PLASTICS AND GENERAL PURPOSE SENSORS
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/Constantan
Lead ProtectionL - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire Braid
3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Junction Style & AttachmentType GB Is Standard For T/CsGB - Grounded And Brazed
Lead LengthSpecify In Inches
Style CodeGeneral PurposeShim Mount
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket
3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Junction Style & AttachmentType GB Is StandardGB - Grounded And Brazed
Lead LengthSpecify In Inches
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket
Shim Dimensions2 - A=1/2" B=5/8"3 - A=3/4" B=3/4"4 - A=1" B=1"
Shim Material1 - .008 Thk. Stainless Steel2 - .010 Thk. Stainless Steel3 - .016 Thk. Brass4 - .016 Thk. Copper
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/Constantan
Pad Material1 - .010 Thk Stainless Steel2 - .024 Thk. Stainless Steel3 - .024 Thk. Brass4 - .024 Thk. Copper
Pad Dimensions2 - A=1 1/2" B=1/2"
3 - A=3/4" B=3/4"4 - A=1" B=1"
Style CodeGeneral PurposePad Mount
Lead Protection
L - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass Sleeve
-
8/11/2019 Termopares (Catalogo Completo) (2)
14/50
DURATHERMProcessing Systems, Inc.
3-13
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Lead ProtectionL - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire Braid
Style GR Ring Mount Sensors
Ring mount sensors can be quickly and firmly secured to any flat surfacewith an appropriate size bolt. Ring mount sensors are often used inparallel with other types of sensor to create an average temperature
measurement between surface and internal temperatures. Special ringsizes are available if required.
Style GR Sensor Product Number Definition
GR 3 2 J GC 48 L 1
Style "GR" Ring SensorType "B" Braid Protected Leads Shown
Style GH Hose Clamp Sensors
Hose clamp sensors are designed for fast installation on pipes, round
containers and other cylindrical objects. Sizes larger than those shownin the table can be supplied when required. Custom clamps featuringalternate clamp designs, special strap widths and other strap materialsare also available.
Style GH Sensor Product Number Definition
GH 3 J GC 48 L 1
Style "GH" Hose Clamp Sensor
Type "B" Braid Protected Leads Shown
Junction Style & AttachmentType GB StandardGB - Grounded And Brazed
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/Constantan
Hose Clamp DimensionsFor Sizes Larger Than ShownUse Nominal Desired ClampDiameter As Diameter Code.
1 - 11/16 " to 1 1/4"2 - 1 1/4" to 2 1/4"3 - 2 1/4" to 3 1/4"4 - 3 1/4" to 4 1/4"5 - 4 1/4" to 5"6 - 5" to 6"
Style CodeGeneral PurposeHose Clamp Mount
Lead LengthSpecify In Inches
Style CodeGeneral PurposeRing Mount
Ring Material2 - Stainless Steel Standard3 - Brass4 - Copper
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - Iron/Constantan DualKD - Chromel/Alumel Dual
Lead ProtectionL - Fiberglass Leads
K - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire Braid
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket
3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Junction Style & AttachmentType GB" StandardGB - Grounded And BrazedUC - Ungrounded Special
Lead LengthSpecify In Inches
Ring Dimensions2 - #10 .219 I.D. .312 O.D. .156 Thk.3 - #10 .219 I.D. .312 O.D. .250 Thk.4 - 1/4" .250 I.D. .750 O.D. .125 Thk.5 - 3/8" .406 I.D. .875 O.D. .093 Thk.7 - 1/2" .531 I.D. 1.125 O.D. .125 Thk.
-
8/11/2019 Termopares (Catalogo Completo) (2)
15/50
3-14
Style GN NewburyNozzle Sensors
Style GN Sensor Product Number Definition
GN 6 2 J GR 48 B 0
The style "GN" nozzle sensors are designed as a direct replacementfor the OEM nozzle style thermocouples which are secured in placewith a set screw. The thermocouple is 1/8 inches in diameter and has
a spring supported lead exit.
Style "GN" Newbury Nozzle SensorType "B" Braid Protected Leads Shown
Junction Style & AttachmentType GB StandardGB - Grounded And BrazedUC - Ungrounded And Crimped
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Nozzle Thread2 - 1/4 - 28 Standard3 - 1/4 - 204 - 6 mm x 15 - 8 mm x 1
Style CodeGeneral PurposeNon-Immersion Nozzle
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/Constantan
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor Hose
Style GNN Non-Immersion Nozzle Sensors
The non-immersion nozzle sensors feature an independent rotating
threaded fitting which tightly secures the drill point shaped junctionfitting against the standard angle of a drilled hole. Nozzle threads otherthan those shown can be supplied upon request.
Style GNN Sensor Product Number Definition
GNN 2 J GC 48 L 1
Style "GNN" Non-Immersion Nozzle Sensor
Type "B" Braid Protected Leads Shown
"TRUTEMP" PLASTICS AND GENERAL PURPOSE SENSORS
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
Sensor Lead Termination0 - 3" Split And Stripped Standard1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BX Connector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Lead ProtectionL - Fiberglass LeadsB - S.S. Wire Braid Standard
LengthSpecify In Inches
Junction Style & AttachmentGR - Grounded Radius Tip StandardUR - Ungrounded Radius Tip
Sensor Calibration TypeJ - Iron/Constantan StandardK - Chromel/Alumel
Probe Diameter Code
2 - 1/8 Standard
Lead Exit Code6 - 90 Deg. Exit Standard
Style CodeGeneral PurposeNewbury Style Nozzle
-
8/11/2019 Termopares (Catalogo Completo) (2)
16/50
DURATHERMProcessing Systems, Inc.
3-15
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
The immersion style nozzle sensors feature an independent rotatingthreaded fitting which eliminates lead twisting problems during sensorinstallation. Lead exit angles must be factory formed in the fiberglass
insulated construction. Mineral insulated probe styles can be formedby the customer or ordered with the desired lead exit angle.
All nozzle immersion sensor assemblies are rated at 40,000 PSI at 750F.Fiberglass leads are rated at 900F. Terminations and alternate leadtypes are subject to construction material temperature limitations .
Style "GNI" Immersion Nozzle Sensors
Style "GNI"WithType"6" 90 Degree Lead
Exit Shown
Probe Extension LengthIn Fractional In. By Letter Code (Z = 0)
Probe Mounting LengthIn Whole Inches
Probe Extension LengthIn Whole Inches1 7/8" Extension is Standard
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & Armor
Style "GNI"WithType"3" 45 Degree Lead
Exit Shown
Style "GNI" Blank BoltProd. No. GNI-BB
Probe Mounting LengthIn Fractional In. By Letter Code (Z = 0)
Style GNI Immersion Nozzle Sensors
Style GNI Sensor Product Number Definition
Lead Exit Code0 - 0 Deg. Exit3 - 45 Deg. Exit6 - 90 Deg. Exit
Construction CodeF - Fiberglass InsulatedM - Mineral Insulated
Style CodeGeneral PurposeImmersion Nozzle
GNI M 3 2 J GD 0 H 3 Z 0 Z 48 B 1
Tip LengthIn Whole Inches
Tip LengthFractional In. By Letter CodeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16
B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Probe Diameter Code2 - 1/8 Standard2 - 3/16
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelJD - Iron/Constantan DualKD - Chromel/Alumel Dual
RT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GR Is Standard For T/CsType RR Is Standard For RTDsGR - Grounded Radius TipUR - Ungrounded Radius TipRR - RTD Radius Tip
Style "GNI" Type "0"Exit And Type "B"Braid ProtectedLeads Shown
-
8/11/2019 Termopares (Catalogo Completo) (2)
17/50
3-16
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
Fixed melt bolt sensors feature a probe sensor element with a rotatingmelt bolt. Lead exit angles must be factory formed in the fiberglassinsulated construction. Mineral insulated probe styles can be formed
by the customer or ordered with the desired lead exit angle.
All melt bolt sensor assemblies are rated at 15,000 PSI at 750F.
Style "GMF" Fixed Melt Bolt Sensors
Probe Extension LengthIn Fractional In. By Letter Code (Z = 0)
Tip LengthIn Whole Inches
Tip LengthFractional In. By Letter CodeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Probe Mounting LengthIn Whole Inches
Probe Extension LengthIn Whole Inches1 7/8" Extension is Standard
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & Armor
Probe Mounting LengthIn Fractional In. By Letter Code (Z = 0)
Style GMF Fixed Melt Bolt Sensors
Lead Exit Code0 - 0 Deg. Exit3 - 45 Deg. Exit6 - 90 Deg. Exit
Construction CodeF - Fiberglass InsulatedM - Mineral Insulated
Probe Diameter Code2 - 1/8 Standard3 - 3/16
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelJD - I ron/Constantan DualKD - Chromel/Alumel DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GR Is Standard For T/CsType RR Is Standard For RTDsGR - Grounded Radius TipUR - Ungrounded Radius TipRR - RTD Radius Tip
Style GMF Sensor Product Number Definition
GMF 6 M 3 2 J GR 0 H 3 Z 0 Z 48 B 1
Melt Bolt LengthIn Inches3 - 3 In. 5 - 5 In.4 - 4 In. 6 - 6 In.
Style CodeGeneral PurposeFixed Melt Bolt
Style "GM" Blank BoltProd. No. GM-BB- Lgth.
Style "GMF" Type
"6" Exit With Type"A" Armor ProtectedLeads
"TRUTEMP" PLASTICS AND GENERAL PURPOSE SENSORS
Style "GMF" Type "0"Exit With Type "B"Braid ProtectedLeads Shown
Style "GMF" Type"3" Exit With Type"3" Plug Leads.Plug Is MountedTo Probe WhenLead Length Is SetTo 0
-
8/11/2019 Termopares (Catalogo Completo) (2)
18/50
DURATHERMProcessing Systems, Inc.
3-17
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Standard Female Jack & Bracket
One time adjustable melt bolt sensors utilize a compression fitting toenable custom adjustment of tip length at installation. This adjustmentfeature simplifies stocking requirements for processors with a variety
of machine sizes and styles requiring assorted tip immersion lengths.Lead exit angles must be factory formed in the fiberglass insulatedconstruction. Mineral insulated probe styles can be formed by thecustomer or ordered with the desired lead exit angle.
All melt bolt sensor assemblies are rated at 15,000 PSI at 750F.
Style "GMA" Adjustable Melt Bolt Sensors
Probe Extension LengthIn Fractional In. By Letter Code (Z = 0)
Probe Extension LengthIn Whole Inches1 7/8" Extension is Standard
Lead LengthSpecify In Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & Armor
Style GMA One Time Adjustable Melt Bolt Sensors
Style "GM" Blank BoltProd. No. GM-BB- Lgth.
Style "GMA" Type "0"
Exit With Type "B"Braided LeadsShown
Style "GMA" Type"6" Exit With Type"A" Armor ProtectedLeads
Style "GMA" Type"3" Exit With Type"3" Plug Term.Plug Is MountedTo Probe WhenLead Length Is SetTo 0
Probe Mounting LengthIn Fractional In. By Letter Code (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Probe Mounting LengthIn Whole Inches
Probe Diameter Code2 - 1/8 Standard3 - 3/16
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelJD - Iron/Constantan DualKD - Chromel/Alumel DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Junction Style And Tip ShapeType GR Is Standard For T/CsType RR Is Standard For RTDsGR - Grounded Radius TipUR - Ungrounded Radius TipRR - RTD Radius Tip
Lead Exit Code0 - 0 Deg. Exit3 - 45 Deg. Exit6 - 90 Deg. Exit
Construction CodeF - Fiberglass InsulatedM - Mineral Insulated
Melt Bolt LengthIn Inches3 - 3 In. 5 - 5 In.4 - 4 In. 6 - 6 In.
Style CodeGeneral PurposeAdjustable Melt Bolt
Style GMA Sensor Product Number Definition
GMA 6 M 3 2 J GR 3 Z 0 Z 48 B 1
-
8/11/2019 Termopares (Catalogo Completo) (2)
19/50
Style GFX Flexible Sensor Extensions
Flexible sensor extensions allow removal of sensors without the needof disturbing system wiring. Lead styles include plain and protectedconfigurations. While many common lead systems are offered as
standard, special flexible extensions can be constructed with anydesired combination of special leads or terminations.
Style GFX Sensor Product Number Definition
GFX J 72 B 3A 3B
Style CodeGeneral PurposeFlexible Sensor Extension
3-18
"TRUTEMP" PLASTICS AND GENERAL PURPOSE SENSORS
Style "GFX" Flexible Sensor Extensions
Extension Lead LengthIn Whole Inches
Lead ProtectionL - Fiberglass LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & Armor
Extension Termination "B"0B - 3" Split And Stripped1B - 3" Split With Spade Lugs2B - 3" Split With Spade Lugs & BX Connector3B - Standard Male Plug & Bracket3BA - Solid Pin Plug & Bracket4B - Standard Female Jack & Bracket5B - Standard Plug & Jack With Bracket6B - Miniature Plug & Bracket7B - Miniature Jack & Bracket8B - Miniature Plug & Jack With Bracket9B - 1/4" Female Push On10B- 3/16" Female Push On
Extension Termination "A"0A - 3" Split And Stripped1A - 3" Split With Spade Lugs2A - 3" Split With Spade Lugs & BX Connector3A - Standard Male Plug & Bracket3AA - Solid Pin Plug & Bracket4A - Standard Female Jack & Bracket5A - Standard Plug & Jack With Bracket6A - Miniature Plug & Bracket7A - Miniature Jack & Bracket8A - Miniature Plug & Jack With Bracket9A - 1/4" Female Push On10A- 3/16" Female Push On
Extension Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/Constantan
JD - I ron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 WireRT3D - RTD 100 Ohm 3 WireRT4D - RTD 100 Ohm 4 Wire
Style "GFX" WithType "A" LeadProtection.ExtensionTermination "A"Type "4A"ExtensionTermination "B"Type "2B"
Style "GFX" WithType "B" LeadProtection.ExtensionTermination "A"Type "3A"ExtensionTermination "B"Type "2B"
Style "GFX" WithType "B" LeadProtection.ExtensionTermination "A"Type "6A"ExtensionTermination "B"Type "3B"
-
8/11/2019 Termopares (Catalogo Completo) (2)
20/50
DURATHERMProcessing Systems, Inc.
3-19
"TRUTEMP" Drawn Metal Sheathed Cable Sensors
The "TRUTEMP" drawn cable sensors feature durability, fast response and high
temperature capabilities. Drawn cable sensor constructions combine precision
fabrication techniques with premium quality mineral insulated cable and featurerugged construction in a particularly compact size.
The standard construction consists of an appropriate pair of elements embedded
in compacted ceramic and encased in an appropriate tubular sheath. Theseelements are welded to form a thermocouple junction or attached to RTD sensor
elements. A wide variety of standard and custom fittings can be added to thesensor to simplify installation and application. The lead end of the cable is typically
equipped with connectors or leads to accommodate connection to control system
wiring.
1
Durable Drawn Cable Construction. Ceramic insulated sensor elements are
sheathed in high temperature alloy tubing and drawn to final dimensions. The
resulting sheathed cable construction protects the internal elements from oxidationand corrosion as well as providing protection from mechanical abuse. The highstrength cable construction can be readily formed into most desired configurations
with no damage to the sheath or elements. The cable in its' standard, dead soft,
bright annealed condition can be formed around a mandrel with a minimumdiameter equal to two times the cable diameter.
2
Corrosion Resistant Alloy Sheath.Common sheath materials include 304, 310,
316 series stainless steels and Alloy 600. Other high temperature and corrosion
resistant sheath materials are also available. The mineral insulated, cable stylethermocouple can be manufactured with a sheath of virtually any malleable alloy.
3High Quality Thermocouple Alloys.Available sensor calibrations include a fullselection of common base metal alloys including type J, K, E and T. Noble metalsensor alloys such as type R and S are also available.
4
Precision Welded Sensor Junctions. Available junctions include grounded,
ungrounded and exposed ungrounded styles. Special welding techniques allow
precise control of welded tip dimension and allows subsequent shaping of the tipwhen required.
5
Compact Sensor Configuration.A wide range of cable sensor sizes with diameters
of .020 to .250 inches permits simple installation into restricted access areas of anapplication. Single and multiple element thermocouple configurations are readilymanufactured.
6
Superior Lead Systems.All lead style cable thermocouples feature precision
welded element to lead connections. These connections are housed in a protectivemetal transition fitting filled with an electrical grade potting compound. A full
selection of lead styles and lead restraints provide additional abuse resistance
when required. A wide variety of connectors, spade lugs and other terminationdevices are also available.
5
6
4
3
2
1
-
8/11/2019 Termopares (Catalogo Completo) (2)
21/50
"TRUTEMP" MINERAL INSULATED CABLE SENSORS
3-20
Welding Attachment Procedures
The cable portion of a sensor assembly can be welded or brazedto the application provided that care is taken to avoid melting
through the sheath. In cases where the cable is .040 or smalle
in diameter we recommend the use of a weld sleeve. This sleevecan be factory installed and would consist of a .010 to .015 wal
tube swaged into place on the cable.
Metal Sheathed Cable Sensor Specifications And Application Data
Cable Sheath Materials
Duratherm mineral insulated cable can be fabricated with asheath consisting of virtually any malleable metal. All cablematerial is annealed in a protective atmosphere to provide a
bright and ductile finished product. The table below outlines
the most common cable sheath materials and their maximumrecommended operating temperatures under continuous
exposure to an oxidizing atmosphere.
Custom Sheathed Cable Sensors
Custom sensors with virtually any desired combination ospecial design features can be readily manufactured. Oumodern CNC equipped machine shop ensures in-house contro
of quality and delivery of component parts. Common design
variations such as special fittings, flanges and connectors aresupplied on a routine basis.
Duratherm has produced thousands of sophisticated, specia
purpose sensors and would welcome the opportunity to quote
design and manufacture any custom sensor your applicationrequires.
Junction Configurations
Duratherm offers three basic thermocouple junctions. Exposed
junctions have the best thermal response but bared junction isunprotected. Grounded junctions offer the next best therma
response and the junction is sealed. Ungrounded junctionsfeature slightly lower thermal response than the grounded type
but are sealed and electrically isolate the junction from the
sensor sheath. Grounded and ungrounded junctions of cablesensors .040 and greater in diameter can be provided with
shaped tip configurations to enhance response.
Forming Of Cable Material
The fully annealed, ductile cable portion of any assembly can
be readily formed into any desired configuration. As a genera
rule, the cable can be formed around a mandrel equal to twicethe sheath outside diameter. Note that repeated bending o
mineral insulated cable will require additional annealing of thebend area.
UngroundedRadius Tip
GroundedRadius Tip
UngroundedDrill Tip
GroundedDrill Tip
GroundedFlat Tip
UngroundedFlat Tip
ExposedUngrounded
Standard Junction Styles
Cable Insulation Materials
Standard cable insulation consists of standard or high purity
magnesium oxide powder. Other insulation materials can besupplied when required. Note that cable insulation materials
are normally selected on the basis of high temperature insulationresistance. The ceramic insulation is compacted to near
theoretical density during the manufacturing process, resultingin high heat transfer rates and rapid thermal response.
Calibration Tolerances
All mineral insulated cable sensor materials meet or exceedANSI standards. "TRUTEMP" cable sensor assemblies meet or
exceed the standard tolerances of ANSI Circular MC96.1-1982.
Special tolerances meeting the standards of ANSI MC96.1-1982can also be supplied when required.
Dimensional Tolerances
htaehS htaehS htaehS htaehS htaehSlairetaM lairetaM lairetaM lairetaM lairetaM
mumixaM mumixaM mumixaM mumixaM mumixaMerutarepmeT erutarepmeT erutarepmeT erutarepmeT erutarepmeT
noitamrofnInoitacilppA noitamrofnInoitacilppA noitamrofnInoitacilppA noitamrofnInoitacilppA noitamrofnInoitacilppA
SS403 .F0561
.C009
doofnidesU.htaehserutarepmetwolnommoctsoM
rehtodnagnissecorpscitsalp,gnigakcap,gnissecorp.deriuqersiecnatsisernoisorrocerehwseirtsudni
SS613 .F0561
.C009
sselniatscitinetsuafoecnatsisernoisorroctsehgiHdnagnissecorpdoofniyltneuqerftsomdesU.sleets
.seirtsudnilacimehc
SS013 .F0012
.C0511
dnaSS403otroirepusylthgilsecnatsisernoisorroCelitcudsseL.ecnatsisertaehrehgihyllaitnatsbus
.SS403nahtlairetam
006
yollA
.F0512
.C0112
yreV.lairetamhtaehseruarepmethgihnommoctsoMhgihtnellecxednahtgnertserutarepmethgihdoog
.ecnatsisernoitadixoerutarepmet
secnareloThtgneLeborPdelbmessAdradnatS secnareloThtgneLeborPdelbmessAdradnatS secnareloThtgneLeborPdelbmessAdradnatS secnareloThtgneLeborPdelbmessAdradnatS secnareloThtgneLeborPdelbmessAdradnatS
retemaiDelbaC retemaiDelbaC retemaiDelbaC retemaiDelbaC retemaiDelbaC .nI42=.htgLeborP
930.nahTsseL950.oT040.
retaerGdnA060.
hcnI4/1hcnI61/3
hcnI8/1
htgneLfO%1htgneLfO%4/3htgneLfO%2/1
ecnareloTretemaiDelbaC ecnareloTretemaiDelbaC ecnareloTretemaiDelbaC ecnareloTretemaiDelbaC ecnareloTretemaiDelbaC
750.-010.390.-850.881-490.005-981.
5000.-100.+100.
100.-200.+100.-300.+
secnareloTdaeLelbixelFdelbmessA secnareloTdaeLelbixelFdelbmessA secnareloTdaeLelbixelFdelbmessA secnareloTdaeLelbixelFdelbmessA secnareloTdaeLelbixelFdelbmessA
htgneLdaeL htgneLdaeL htgneLdaeL htgneLdaeL htgneLdaeL ecnareloThtgneLdaeL ecnareloThtgneLdaeL ecnareloThtgneLdaeL ecnareloThtgneLdaeL ecnareloThtgneLdaeL
.tF01nahTsseLregnoLdnA.tF01
sehcnI0-6+htgneLfO%0-%5+
-
8/11/2019 Termopares (Catalogo Completo) (2)
22/50
DURATHERMProcessing Systems, Inc.
Style MS Cable Sensor With Stripped And Sealed Termination
Style MS Sensor Product Number Definition
Cable sensors with stripped and sealed terminations are most oftenused as replacement elements for various sensor constructions. Thesesensors can also be user equipped with fittings and connectors suitable
for a wide range of custom thermal control applications.
MS 040 304 J GR 0 H 0 Z
3-21
Style CodeMI Cable ProbeStripped & SealedLead Termination
Strip LengthIn Fractional In.By Letter Code
Style "MS" WithGrounded Junction And
Radius Tip
Style "MS" WithUngrounded Junction
And Radius Tip
Style "MS" WithExposed Ungrounded
Junction
Probe Diameter
.020
.025
.031
.040
.250
.313
.375
.500
.063
.094
.125
.187
Sheath Material Code304 - 304 Stainless Steel310 - 310 Stainless Steel316 - 316 Stainless Steel600 - 600 Alloy
Junction Style And Tip ShapeType GR Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Length
In Whole Inches
Probe LengthIn Fractional In. By Letter CodeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Strip LengthIn Whole Inches
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - Iron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 Wire (Probe Dia. =>.125)RT3D - RTD 100 Ohm 3 Wire (Probe Dia. =>.125)
RT4D - RTD 100 Ohm 4 Wire (Probe Dia. =>.125)
-
8/11/2019 Termopares (Catalogo Completo) (2)
23/50
Style MC Cable Sensor With Connector Termination
The style "MC" cable sensors are equipped with attached connectors.A wide selection of standard connectors and mounting methods areoffered. Customer specified connectors and mounting methods not
shown can also be supplied when required.
"TRUTEMP" MINERAL INSULATED CABLE SENSORS
Style MC Sensor Product Number Definition
MC 040 304 J GR 8 H 1 1
3-22
Style CodeMI Cable ProbeConnector TypeTermination
Style "MC" WithStd. Plug And InsertCompression Fitting
Style "MC" With MiniaturePlug And Insert
Compression Fitting
Style "MC" WithStd. Plug And Bracket
Braze Fitting
Style "MC" With MiniaturePlug And Braze
Insert Fitting
Style "MC" WithStd. Plug And BracketCompression Fitting
Probe Diameter
.020
.025
.031
.040
.250
.313
.375
.500
.063
.094
.125
.187
Sheath Material Code304 - 304 Stainless Steel310 - 310 Stainless Steel316 - 316 Stainless Steel600 - 600 Alloy
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - I ron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 Wire (Probe Dia. =>.125)RT3D - RTD 100 Ohm 3 Wire (Probe Dia. =>.125)
RT4D - RTD 100 Ohm 4 Wire (Probe Dia. =>.125)
Junction Style And Tip ShapeType GR Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe LengthIn Whole Inches
Probe LengthIn Fractional In. By Letter CodeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Connector1 - Std. Plug2 - Std. Jack3 - Std. Plug & Jack4 - Miniature Plug5 - Miniature Jack6 - Miniature Plug & Jack
Mounting1 - Insert Braze Fitting2 - Braze Bracket3 - Insert Compression Fitting4 - Bracket Compression Fitting
-
8/11/2019 Termopares (Catalogo Completo) (2)
24/50
DURATHERMProcessing Systems, Inc.
Style MW Cable Sensor With Wafer Termination
The wafer termination of the style "MW" cable sensor is most useful inapplications where the termination area is not exposed to contaminants.This termination style can be used on all cable sensor diameters but is
most practical for probes .125 diameter and larger.
Style MW Sensor Product Number Definition
3-23
Style CodeMI Cable ProbeWafer TypeTermination
MW 040 304 J GR 6 Z 1 1 S4
Style "MW" WithBrazed NPT Fitting
Probe Diameter
.063
.094
.125
.187
.020
.025
.031
.040
.250
.313
.375
.500
Sheath Material Code304 - 304 Stainless Steel310 - 310 Stainless Steel316 - 316 Stainless Steel600 - 600 Alloy
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - Iron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 Wire (Probe Dia. =>.125)RT3D - RTD 100 Ohm 3 Wire (Probe Dia. =>.125)RT4D - RTD 100 Ohm 4 Wire (Probe Dia. =>.125)
Junction Style And Tip ShapeType GR Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting Length
In Whole Inches
Probe Mounting LengthIn Fractional In. By Letter CodeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Wafer Type And Specifications1 - Ceramic (Steatite)1000 F2 - Nylon Thermoplastic 350 F.3 - Ryton Thermoplastic 500 F.
Fitting MaterialB1 - BrassS1 - Carbon SteelS4 - 304 SSS6 - 316 SS
Attachment And Fitting1 - Brazed To Flange2 - 1/8" NPT Compression3 - 1/2" NPT Compression
4 - Brazed To 1/8" NPT Single5 - Brazed To 1/2" NPT Single6 - Brazed To 3/4" NPT Single7 - Brazed To 1" NPT Single
Style "MW" With BrazedFlange Fitting
Style "MW" WithCompression Fitting
-
8/11/2019 Termopares (Catalogo Completo) (2)
25/50
Style MH Cable Sensor With Head Termination
The head style cable termination features an internal terminal block,allowing rapid connection to a variety of lead systems. A wide selectionof standard fittings ensures compatibility with all common applications.
Custom cable sensors requiring formed cable configurations,nonstandard heads or special fittings are readily available.
Style MH Sensor Product Number Definition
"TRUTEMP" MINERAL INSULATED CABLE SENSORS
3-24
MH A 040 304 J GR 8 H 1 S4 1
Style CodeMI Cable ProbeHead Termination
Probe Diameter
.020
.025
.031
.040
.250
.313
.375
.500
.063
.094
.125
.187
Sheath Material Code304 - 304 Stainless Steel310 - 310 Stainless Steel316 - 316 Stainless Steel600 - 600 Alloy
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - I ron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan Dual
RT2D - RTD 100 Ohm 2 Wire (Probe Dia. =>.125)RT3D - RTD 100 Ohm 3 Wire (Probe Dia. =>.125 )RT4D - RTD 100 Ohm 4 Wire (Probe Dia. =>.125)
Junction Style And Tip ShapeType GR Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole Inches
Probe Mounting LengthIn Fractional In. By Letter CodeFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
Fitting Size And Style1 - 1/8" NPT Single2 - 1/2" NPT Single3 - 3/4" NPT Single4 - 1" NPT Single
Head OpeningConduit Thread1 - 1/2" NPT2 - 3/4" NPT
Fitting MaterialB1 - BrassS1 - Carbon SteelS4 - 304 SSS6 - 316 SS
9 - 1/8" NPT Compression10 - 1/2" NPT Compression
5 - 1/8" NPT Double6 - 1/2" NPT Double7 - 3/4" NPT Double8 - 1" NPT Double
Style "MH" With DoubleNPT Fitting
Style "MH" WithCompression Fitting
Style "MH" With SingleNPT Fitting
Head Material CodeA - AluminumI - IronN - Nylon
-
8/11/2019 Termopares (Catalogo Completo) (2)
26/50
DURATHERMProcessing Systems, Inc.
Style MM Cable Sensor With Metal Transitioned Lead Termination
Cable sensors with metal transitioned leads are particularly versatile.Sensors can be used "as is" or equipped with fittings and connectorssuitable for use in specific customer applications. Lead options include
a variety of plain and protected leads with assorted terminations.
Style MM Sensor Product Number Definition
MM A 125 J GD 4 H 48 B 1
3-25
Transition StyleA - .375 DiameterB - .312 Diameter
Probe Diameter
.020
.025
.031
.040
.250
.313
.375
.500
.063
.094
.125
.187
Style CodeMI Cable ProbeMetal TransitionedLead Termination
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - Iron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 Wire (Probe Dia. =>.125)RT3D - RTD 100 Ohm 3 Wire (Probe Dia. =>.125)RT4D - RTD 100 Ohm 4 Wire (Probe Dia. =>.125)
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole Inches
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket4 - Standard Female Jack & Bracket
Lead LengthSpecify In Inches
Probe Mounting Length
Fractional In. By Letter Code1 1/4" Extension is StandardFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Lead ProtectionL - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & Armor
Style "MM" With Style"A" Transition And
Armor Fitting
Style "MM" With
Style "B" TransitionAnd Strain Relief
Spring
Style "MM" WithStyle "B" TransitionAnd Armor Fitting
Style "MM" With Style"A" Transition And
Strain Relief Spring
-
8/11/2019 Termopares (Catalogo Completo) (2)
27/50
"TRUTEMP" MINERAL INSULATED CABLE SENSORS
Style MT Cable Sensor With Thermoset Molded Transition Lead Termination
3-26
Cable sensors with thermoset molded lead transitions provide functionssimilar to the metal transitioned style "MM" but offer additional moistureresistance. Thermoset molded transitions are rated at 800F.
continuous. Lead options include a variety of plain and protected leadswith assorted terminations.
Style MT Sensor Product Number Definition
Transition StyleA - .375 DiameterB - .312 Diameter
Probe Diameter
.020
.025
.031
.040
.250
.313
.375
.500
.063
.094
.125
.187
Style CodeMI Cable ProbeMetal TransitionedLead Termination
Sensor Calibration TypeJ - Iron/ConstantanK - Chromel/AlumelT - Copper/ConstantanE - Chromel/ConstantanJD - I ron/Constantan DualKD - Chromel/Alumel DualTD - Copper/Constantan DualED - Chromel/Constantan DualRT2D - RTD 100 Ohm 2 Wire (Probe Dia. =>.125)RT3D - RTD 100 Ohm 3 Wire (Probe Dia. =>.125)RT4D - RTD 100 Ohm 4 Wire (Probe Dia. =>.125)
Junction Style And Tip ShapeType GD Is Standard For T/CsType RR Is Standard For RTDsGD - Grounded Drill TipUD - Ungrounded Drill TipGR - Grounded Radius TipUR - Ungrounded Radius TipGF - Grounded Flat TipUF - Ungrounded Flat TipEX - Exposed Ungrounded TipRD - RTD Drill PointRR - RTD Radius TipRF - RTD Flat Tip
Probe Mounting LengthIn Whole Inches
Sensor Lead Termination0 - 3" Split And Stripped1 - 3" Split With Spade Lugs2 - 3" Split With Spade Lugs & BXConnector3 - Standard Male Plug & Bracket3A - Solid Pin Plug & Bracket4 - Std. Female Jack & Bracket
Lead LengthSpecify In Inches
Probe Mounting Length
Fractional In. By Letter Code1 1/4" Extension is StandardFractional Letter Codes (Z = 0)A = 1/16 F = 3/8 K = 11/16B = 1/8 G = 7/16 L = 3/4C = 3/16 H = 1/2 M = 13/16D = 1/4 I = 9/16 N = 7/8E = 5/16 J = 5/8 O = 15/16
5 - Standard Plug & Jack With Bracket6 - Miniature Plug & Bracket7 - Miniature Jack & Bracket8 - Miniature Plug & Jack With Bracket9 - 1/4" Female Push On10- 3/16" Female Push On
Lead ProtectionL - Fiberglass LeadsK - Kapton LeadsT - Teflon LeadsS - Fiberglass SleeveB - S.S. Wire BraidA - S.S. Armor HoseBA - S.S Braid & Armor
Style "MT" With Style"A" Transition And
Armor Fitting
Style "MT" With
Style "B" TransitionAnd Strain Relief
Spring
Style "MT" WithStyle "B" TransitionAnd Armor Fitting
Style "MT" With Style"A" Transition And
Strain Relief Spring
MT A 125 J GD 4 H 48 B 1
-
8/11/2019 Termopares (Catalogo Completo) (2)
28/50
DURATHERMProcessing Systems, Inc.
Style MMID Miniature Industrial Duty Thermocouples
Sensor accuracy and reliability are essential to precise temperaturecontrol of multicomponent industrial processing systems. Our StyleMMID mineral insulated thermocouple with a medium temperature
range transition is the economical choice for these demandingapplications. These quality thermocouples provide optimumperformance in process systems where the lead transition is notexposed to temperatures in excess of its 550F. rat ing.
All alloys used in the cable and leads meet or exceed the ANSIspecifications for thermocouple grade wire. The standard Tefloninsulated lead system features color coded Teflon insulation over eachstranded wire and a protective wrapped and fused Teflon outer coverover the wire pair for additional abuse resistance. The precision weldedelement and lead connections are epoxy encapsulated into a durablestainless steel transition fitting to form a strong, secure and sealedlead connection system.
The thermocouple probe exits the transition through a one inch lengthof Teflon sleeve which provides a strain relief function that further
protects the cable when bends are made in the transition area. Thestandard epoxy secured lead exit is extremely durable and can bereinforced with integral crimp when additional strength is desired.
Most standard configurations of this high performance thermocouplefeature cable diameters in the range of .020 to .125 inches and includea grounded junction configuration in a type J calibration. Common
options include ungrounded junctions and type K, type T and typeE calibration. Additional special calibrations are also available .
The standard transition fitting with epoxy encapsulation and teflon leads
is limited to a maximum operating temperature of 550F. The 1650F.rated probe portion of the thermocouple should be specified with alength sufficient to clear the transition and leads from areas of intenseheat. If the transition fitting and leads must be located in areas which
could approach the 550F. limit, consider the use of alternate
thermocouple assembly, such as the Style MHID with its 800F.transition. All lead styles are designed to accommodate a variety oflead protection systems including stainless steel wire braid and stainlesssteel armor hose.
These thermocouples can be readily installed into small diameterthermowells, drilled holes or grooves. When required, tabs and otherfastening devices can be induction brazed to the cable to simplify theirattachment to the component surfaces.
3-27
-
8/11/2019 Termopares (Catalogo Completo) (2)
29/50
Style MMID Miniature Industrial Duty Thermocouples
Features And Configurations
Standard transition dimensions and lead gauges for the most common
thermocouple probe diameters are detailed in the table below. Werecommend the use of the transitions and leads noted as standardwhenever possible, but do offer optional transition sizes and leadgauges to accommodate those applications where tooling spacelimitations or lead requirements dictate their use.
Design options include special calibrations, ungrounded and exposedjunctions and a selection of lead protection systems and terminationstyles. A completed selection of fittings and tabs are available to securesingle or multiple thermocouples to the desired component.
Selection And Ordering
Standard versions of these industrial duty thermocouple assemblies
include type J calibration, 304 series stainless steel sheathed minerainsulated cable and a grounded junction configuration. Stock leadsystems include duplex Teflon insulated thermocouple grade wire.
The most popular thermocouples are stocked as complete assembliesminus the junction and include 14" probe length with 48" and 72" leadsThese assemblies, designated Stock in the table below, can be cuand junctioned to customer specifications for same day shipment. Toorder by product number, replace the codes in the product numbeexample below with your desired specifications.
The product code example shown above defines a Style MMIDthermocouple with a probe diameter of .025 inches in a type Jcalibration with grounded junction and 10 inch probe length. A stocktransition diameter was selected. A 48 inch lead length was specifiedin the standard Teflon insulated construction.
The standard lead termination for the Style MMID thermocouplefeatures 2 inch split leads with 1/2 inch stripped ends. Alternatetermination requirements must be noted on your order. If fasteningdevices or fittings are required please provide details or contact ouengineering department for assistance.
"TRUTEMP" MINERAL INSULATED CABLE SENSORS
Lead Type
T - TeflonK - KaptonF - Fiberglass
Lead Length
SpecifyDesiredLengthIn Inches
Style Code
Miniature MediumTemperatureIndustrial DutyThermocouple
Probe Dia.
Select FromDimensionalChart ShownAbove
Probe Length
SpecifyDesiredLengthIn Inches
Junction
G - GroundedU - UngroundedE - Exposed
Calibration
Type JType KType TType E
Style MMID Thermocouple Product Number Definition
MMID 025 J G 10 S 48 T
Transition Code
Select FromDimensionalChart ShownAbove
3-28
elbaTkcotSdnAataDlanoisnemiDelpuocomrehTytuDlairtsudnIerutainiMerutarepmeTmuideM"DIMM"elytS
*eborP*
retemaiD
noitisnarT noitisnarT
htgneL
daeL
eguaG
elbaliavA
sA
*eborP*
retemaiD
noitisnarT noitisnarT
htgneL eguaGdaeL
elbaliavA
sA.aiD edoC .aiD edoC
"020. "521. O "00.1 eguaG62# noitpO "040. "741. O "000.1 eguaG42# noitpO
"020. "561. S "00.1 eguaG42# kcotS "040. "561. S "521.1 eguaG42# kcotS
"520. "521. O "00.1 eguaG62# noitpO "260. "741. O "000.1 eguaG42# noitpO
"520. "561. S "00.1 eguaG42# kcotS "260. "561. S "521.1 eguaG02# kcotS
"130. "521. O "00.1 eguaG62# noitpO "390. "781. S "521.1 eguaG02# kcotS
"130. "561. S "00.1 eguaG42# kcotS "521. "052. S "521.1 eguaG02# kcotS
-
8/11/2019 Termopares (Catalogo Completo) (2)
30/50
DURATHERMProcessing Systems, Inc.
Sensor accuracy and reliability are essential to the precise control oftemperatures in multicomponent industrial processing systems. Ourmineral insulated Style MHID thermocouple with its high temperature
lead transition has performed consistently in the most demanding ofapplications. These high quality thermocouples are manufactured tostringent specifications and have gained a reputation for unsurpassedperformance and reliability.
All alloys used in the cable and leads meet or exceed the ANSIspecifications for thermocouple grade wire. The standard Kaptoninsulated lead system features color coded Kapton insulation over eachstranded wire and a protective wrapped and fused Kapton outer coverover the wire pair for additional abuse resistance. The precision weldedelement and lead connections are encapsulated in a high temperatureelectrical cement and housed within a miniature stainless steel transitionfitting for maximum durability.
The stainless steel sheathed cable portion of the thermocouple isinduction brazed to the transition for maximum strength. The lead exit
area is further reinforced by means of an integral crimp at the lead endof the transition which secures a protective sleeve and the Kaptoninsulated lead wire tightly to the transition assembly.
Most standard configurations of this high performance thermocouplefeature cable diameters in the range of .020 to .125 inches and includea grounded junction configuration in a type J calibration. Common
options include ungrounded junctions and type K, type T and typeE calibration. Additional special calibrations are also available .
The standard transition fitting with electrical cement encapsulation andKapton leads is limited to a maximum operating temperature of 800F.If the area in the tool where the transition fitting and leads are located issubject to temperatures greater than this 800F. limit, special leadmaterials can be supplied to further raise operating temperaturecapabilities. While not as resistant to abrasion as Kapton insulated leads,fiberglass insulated leads increase the maximum operatingtemperatures to 900F. continuous. All lead styles are designed toaccommodate a variety of lead protection systems including stainlesssteel wire braid and stainless steel armor hose.
These thermocouples can be readily installed into small diameterthermowells, drilled holes or grooves. When required, tabs and other
fastening devices can be induction brazed to the cable to simplify theirattachment to the component surfaces.
Style MHID Miniature Industrial Duty Thermocouples
3-29
-
8/11/2019 Termopares (Catalogo Completo) (2)
31/50
Features And Configurations
Standard transition dimensions and lead gauges for the most common
thermocouple probe diameters are detailed in the table below. Werecommend the use of the transitions and leads noted as standardwhenever possible, but do offer optional transition sizes and leadgauges to accommodate those applications where tooling spacelimitations or lead requirements dictate their use.
Design options include special calibrations, ungrounded and exposedjunctions and a selection of lead protection systems and terminationstyles. A completed selection of fittings and tabs are available to securesingle or multiple thermocouples to the desired component.
Selection And Ordering
Standard versions of these industrial duty thermocouple assemblies
include type J calibration, 304 series stainless steel sheathed minerainsulated cable and a grounded junction configuration. Stock leadsystems include duplex Kapton insulated thermocouple grade wire.
The most popular thermocouples are stocked as complete assembliesminus the junction and include 14" probe length with 48" and 72" leadsThese assemblies, designated Stock in the table below, can b